You are on page 1of 8

MLM 226 Faceplates Installation Guide

This guide provides instructions for installing the following Extron MediaLink™
Mounting Options faceplates, which are designed for use with the MLC 226 IP
MediaLink Controller.

MLM 226 Faceplates


The following MLM 226 faceplates are available for the MLC 226 IP MediaLink
Controller.
The MLM 226 L, MLM 226 3GWP, and MLM 226 5GWP faceplates are shipped
with the MLC 226 IP controller, depending on the controller configuration that is
ordered. The rest of the mounting options described below may be ordered
separately as replacements, or for use with an MLC 226 IP that is ordered without
a faceplate.
• MLM 226 L — A low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W) lectern/
furniture-mounting faceplate. This faceplate is required when you are mounting
an MLC 226 IP using an optional UCM RAAP or UCM 10X8P mounting kit.
Part numbers: 70-342-02 (black), 70-342-03 (white), 70-342-05 (RAL9010 white)

• MLM 226 LAAP — A low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W)


lectern/furniture-mounting faceplate with an opening that accommodates four
single-space AAPs
Part numbers: 70-343-02 (black), 70-343-03 (white), 70-343-05 (RAL9010 white)

• MLM 226 3GWP — A three-gang (4.50" H x 6.40" W [11.43 cm H x 16.26 cm W])


faceplate that can be mounted to a mud ring (mounting bracket), an Extron
Surface Mount Box, an Extron External Wall Box, or a standard electrical box
Part numbers: 70-376-02 (black), 70-376-03 (white), 70-376-05 (RAL9010 white)

68-919-01, Rev. C
10 05

MLM 226 Faceplates • Installation Guide 1


MLM 226 Faceplates Installation Guide, cont’d

• MLM 226 5GWP — A five-gang (4.50" H x 10.13" W [11.43 cm H x 25.73 cm W])


faceplate with an opening that accommodates four single-space AAPs. It can
be mounted to a mud ring, an Extron Surface Mount Box, an Extron External
Wall Box, or a standard electrical box.
Part numbers: 70-377-02 (black), 70-377-03 (white), 70-377-05 (RAL9010 white)

• MLM 226 7GWP — A seven-gang (4.50" H x 13.75" W [11.43 cm H x


34.46 cm W]) faceplate with two openings that accommodate four single-space
AAPs each (eight AAPs total). It can be mounted to a mud ring, an Extron
Surface Mount Box, an Extron External Wall Box, or a standard electrical box.
Part numbers: 70-340-02 (black), 70-340-03 (white), 70-340-05 (RAL9010 white)

Replacing an MLC 226 IP Faceplate with an MLM Faceplate


1. Using a small Phillips screwdriver, remove the four faceplate attachment screws
(marked 1 in the diagram below), and save them for later use.
CAUTION Do not remove these screws while the MLC is installed in a wall or
furniture, or the controller may fall down into the wall or furniture.

1 PROJECTOR 1
ON OFF AUTO
IMAGE AUX
VCR DVD
VIDEO
1 2 3
VOLUME MUTE 4 5 6

LAPTOP PC

1 IR CONFIG 1

Extron MLC 226 IP

2 MLM 226 Faceplates • Installation Guide


2. Lift the faceplate off the MLC 226 IP, as shown below.

X
AU O
E
VID
D
DV
R
VC
TO PC
AU GE
A
IM
F OP
OF PT
TE LA
ON MU

3
6

2
5
R
TO 1
EC
OJ 4
PR

IG
NF
CO

ME IP
LU IR
VO 26
C2
ML

n
tro
Ex

3. Align the openings in the new MLM faceplate with the controller ’s buttons,
knob, and LEDs, then place the new faceplate on the MLC 226 IP.
4. Replace the four screws removed in step 1, and hand tighten them.
5. Install the MLC 226 IP controller with the MLM 226 faceplate in a wall or
furniture as appropriate.
If necessary, use the measurements given on the appropriate template in the
next section as guidelines for drawing the rectangle that you will cut out of
the installation surface to mount the controller with its faceplate. (Refer to
your MLC 226 IP user’s manual for detailed instructions on preparing the
mounting site.)

Templates
Use one of the following templates as a guide to measure and mark the hole for
installing the MLM 226 faceplate with an attached MLC 226 IP.
CAUTION These templates are not to scale. Use the dimensions shown in the
templates as reference guidelines for measuring and drawing the rectangle
that will be cut out.
The MLC controller requires a depth of at least 2.0" (5.1 cm) inside the wall or
furniture.

MLM 226 Faceplates • Installation Guide 3


MLM 226 Faceplates Installation Guide, cont’d

MLM 226 L template

3.15"
(8.0 cm)

.250" (4 places)
(0.64 cm)

Top Panel

2.9"
(7.4 cm)

SURFACE CUT-OUT AREA


FOR FURNITURE MOUNT
6.5"
(16.5 cm)
5.4"
(13.7 cm) Location of MLC 226 IP

To install MLC 226 IP


and MLM 226 L
directly into furniture,
cut along this line.

.295" (4 places)
(0.75 cm)

TEMPLATE IS NOT FULL SIZE.


Cut-Out Template for Extron's MLM 226 L and MLC 226 IP L

4 MLM 226 Faceplates • Installation Guide


MLM 226 LAAP template

3.15"
(8.0 cm)

2.9"
(7.4 cm)

8.9"
(22.6 cm) Top Panel

10"
(25.4 cm)

SURFACE CUT-OUT
Location of MLC 226 IP
AREA FOR
FURNITURE MOUNT

To install MLC 226 IP


and MLM 226 LAAP
directly into furniture,
cut along this line.

.250" (0.64 cm)

.295" (0.75 cm)


TEMPLATE IS NOT FULL SIZE.
Cut-Out Template for Extron's MLM 226 LAAP

MLM 226 Faceplates • Installation Guide 5


MLM 226 Faceplates Installation Guide, cont’d

MLM 226 3GWP template

4.5"
(11.4 cm)

Top Panel

2.9"
(7.4 cm)

SURFACE CUT-OUT AREA


FOR FURNITURE MOUNT
6.4"
(16.26 cm)
5.4"
(13.7 cm) Location of MLC 226 IP

To install MLC 226 IP


and MLM 226 3GWP
directly into furniture,
cut along this line.

TEMPLATE IS NOT FULL SIZE.


Cut-Out Template for Extron's MLM 226 3GWP and MLC 226 IP

6 MLM 226 Faceplates • Installation Guide


MLM 226 5GWP template

4.5"
(11.4 cm)

2.9"
(7.4 cm)

8.9"
(22.6 cm) Top Panel

10.13"
(25.73 cm)

SURFACE CUT-OUT
AREA FOR Location of MLC 226 IP
FURNITURE MOUNT

To install MLC 226 IP


and MLM 226 5GWP
directly into furniture,
cut along this line.

TEMPLATE IS NOT FULL SIZE.


Cut-Out Template for Extron's MLM 226 5GWP and MLC 226 IP AAP

MLM 226 Faceplates • Installation Guide 7


MLM 226 Faceplates Installation Guide, cont’d

MLM 226 7GWP template


4.5"
(11.4 cm)

2.9"
(7.4 cm)

Top Panel

13.565"
(34.46 cm) Location of MLC 226 IP
12.9"
(32.8 cm)

SURFACE CUT-OUT
AREA FOR
FURNITURE MOUNT

To install MLC 226 IP


and MLM 226 7GWP
directly into furniture,
cut along this line.

TEMPLATE IS NOT FULL SIZE.


Cut-Out Template for Extron's MLM 226 7GWP

Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan
1230 South Lewis Street Beeldschermweg 6C 135 Joo Seng Road, #04-01 Kyodo Building
Anaheim, CA 92805 3821 AH Amersfoort PM Industrial Building 16 Ichibancho
USA The Netherlands Singapore 368363 Chiyoda-ku, Tokyo 102-0082 Japan
714.491.1500 +31.33.453.4040 +65.6383.4400 +81.3.3511.7655
www.extron.com Fax 714.491.1517 Fax +31.33.453.4050 Fax +65.6383.4664 Fax +81.3.3511.7656

8 MLM 226 Faceplates • Installation Guide © 2005 Extron Electronics. All rights reserved.

You might also like