The Sub Project of Reconstructio

Air & curing tank temperatur


HAZAM
Temperature (°C) Curing water According to IS 516 - (1956)

Check time
1 2 3 4 5 6 7 8 9 10 11 12 13

AM - 14.3 12.3

PM 20.1 18.2 16.9

Temperature (°C) Air

Check time
1 2 3 4 5 6 7 8 9 10 11 12 13
AM - 7.2 8.0

PM 18.2 17.3 19.2

Moisture content in Fine Aggregate (%) STOCK

Check time
1 2 3 4 5 6 7 8 9 10 11 12 13

AM

PM

Moisture content in Fine Aggregate (%) HOPPER

Check time
Check time
1 2 3 4 5 6 7 8 9 10 11 12 13

AM 7.1

PM 9.1
ction of Paropakar Maternity and Women`s Hospital
ature monitoring & Surface Moisture Check sheet
ZAMA ANDO CORPORATION
Sample Curing temperature = 27±2°C Month : Decem
Date

14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

11.8 9.8 9.5 14.1 11.0 11.6 13.3 12.2 13.8 12.6 11.6 11.5 11.6 11.2 - -

15.7 11.9 19.4 19.9 15.7 14.7 15.2 14.8 14.4 15.9 15.7 16.2 17.9 18.3 - -

Month : Decem
Date

14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
7.8 9.5 10.0 9.9 11.9 12.3 12.4 11.2 10.0 13.7 10.6 11.2 10.0 10.8 - -

18.6 18.5 19.1 18.2 18.5 18.2 17.1 18.3 17.9 17.0 16.8 17.5 18.2 18.6 - -

TOCK YARD Month : Decem


Date

14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

8.2 8.9 8.9 8.6 8.6 8.9 6.5 10.5 9.3 6.0 - - - -

8.9 8.8 11.3 9.3 8.2 8.5 6.3 10.3 9.1 - - - - -

PER Month : Decem


Date
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

10.1 11.3 11.3 10.5 6.2 13.7 - - - - - -

11.7 9.7 9.7 12.9 12.1 10.5 6.9 6.2 - - - - - - -

Monitored by QA/QC Laboratory Sectio


`s Hospital
ck sheet

Month : December /2017


Monthly
Average
31 (°C)

10.6 11.9

19.2 16.7

Month : December /2017


Monthly
Average
31 (°C)
11.2 10.5

20.1 18.2

Month : December /2017


Monthly
Average
31 (%)

5.6 8.2

5.8 8.7

Month : December /2017


Monthly
Average
(%)
Monthly
Average
31 (%)

- 10.0

- 9.9

Monitored by QA/QC Laboratory Section


The Sub Project o
Air & curing tank temperatur
HAZAM
Temperature (°C) Curing water According to IS 516 - (1956)

Check time
1 2 3 4 5 6 7 8 9 10 11 12 13

AM 13.2 12.3 14.5 14.2

PM 17.4 18.3 19.5 23.4

*from 8 Feburary Using Heater in Curing tank

Temperature (°C) Air

Check time
Check time
1 2 3 4 5 6 7 8 9 10 11 12 13

AM 6 6.0 6 6.0

PM 21.0 21.0 21.0 20

Moisture content in Fine Aggregate (%) STOCK

Check time
1 2 3 4 5 6 7 8 9 10 11 12 13

AM

PM

Moisture content in Fine Aggregate (%) HOPPER


Check time
1 2 3 4 5 6 7 8 9 10 11 12 13

AM

PM
ect of Reconstruction of Bir Hospital
ature monitoring & Surface Moisture Check sheet
ZAMA ANDO CORPORATION
Sample Curing temperature = 27±2°C Month : Febu
Date

14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

16.8 13.3 16.7 14.5 16.3 14.2 14.3 17.5 16.3 15.3

22.3 21.2 21.4 22.3 23.5 21.5 22.7 24.5 23.5 22.8

Month : Febura
Date
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

6.0 6 7 7.0 8.0 7.0 8 8 8 7.0

23.0 21 23.0 23.0 23.0 22.0 22.0 24 23.0 24.0

TOCK YARD Month : Febu


Date

14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

PER Month : Febu


Date

14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Monitored by QA/QC Laboratory Sectio


ck sheet

Month : Feburary /2018


Monthly
Average
31 (°C)

Month : Feburary /2018


Monthly
Average
(°C)
Monthly
Average
31 (°C)

Month : Feburary /2018


Monthly
Average
31 (%)

Month : Feburary /2018


Monthly
Average
31 (%)

Monitored by QA/QC Laboratory Section