You are on page 1of 44

Fast Facts Express Timers & Controls

ABB & SSAC Product Lines


Express Timers & Controls All Part Numbers are
d ex Series Index unless marked QS ( )
In
ABB & SSAC Express Series

Series Number Page Series Number Page Series Number Page Series Number Page
Accessories.................................... 38-40 ECS......................................................31 KSDS....................................................21 RS...........................QS.........................23
ARP......................................................35 FA.........................................................37 KSPD......................QS...........................5 SCR......................................................37
BZ1 . ....................................................39 FB.........................................................37 KSPS......................QS...........................4 TCS.......................................................32
CM-EFS................................................30 FH3P.....................................................37 KSPU......................QS...........................6 TCSA....................................................32
CM-ENS up/down................................36 FS126...................................................23 LCS.......................................................31 TDB......................................................14
CM-ESS................................................29 FS127...................................................23 LLC5.....................................................35 TDI........................................................14
CM-MSS...............................................36 FS146...................................................23 LLP.......................................................40 TDM......................................................14
CM-PFS................................................28 FS155...................................................37 LPM......................................................31 TDR......................................................15
CM-SFS................................................34 HLMU...................................................24 NDS......................................................38 TDS.......................................................14
CM-SRS...............................................33 HRPS/HRIS............ QS...........................7 OT.........................................................38 TDU......................................................22
CT-AHD................................................20 HRPU/HRIU............ QS...........................8 P0XXX-........................................... 39-40 TMV......................................................22
CT-ARS.................................................20 KRPD...................... QS...........................3 P1XXX-........................................... 38-39 TRDU.............................................. 12-13
CT-ERD.................................................15 KRPS...................... QS...........................2 PCR......................................................37 TRU......................................................11
CT-MFD.......................................... 16-17 KSD1....................................................21 PHST....................................................40 WVM.....................................................27
CT-MVS.......................................... 18-19 KSD2....................................................21 PLMU...................................................26
DLMU...................................................25 KSDB....................................................21 PSC......................................................38

The Express Timers & Controls


Catalog includes an overview of the
product information, operation and
specifications. Complete product
details are available in the full line
catalog pages. The Express Timers
& Controls home page provides a fast
and direct path to find the details on
Search by the products in this catalog.
Part Number

Links by
Product Series
Over 10 Million
Download the
Latest Pages
Timers Available
in 2 Days or Less
Links by
Product Type

Express Part
Numbers w/ Links

Terms of Sale

1.) Same day factory shipment on orders received before 3:00 PM EST, M-F
2.) Typical maximum quantity is 25 units. Call factory for lead times on higher quantities.
3.) Minimum factory order amount is $100.00 USD or ship via Next Day Air Shipping Method. See www.abb-control.com for your local ABB Authorized Distributor.
4.) Payment arrangements must be made in advance. Contact Customer Service.

1.) Shipment in two business days on orders received before 3:00 PM EST, M-F
2.) Typical maximum quantity is 25 units. Call factory for lead times on higher quantities.
3.) Minimum factory direct order amount is $100.00 USD. See www.abb-control.com for your local ABB Authorized Distributor.
4.) Payment arrangements must be made in advance. Contact Customer Service.

Publication 1TRC22
No. 1TRC001022C0201
Printed in USA, February, 2008
ABB Inc., SSAC Products, 888-385-1221 8:00AM to 5:00PM CST, M-F; Product Information: www.ssac.com , Find Local ABB Authorized Distributors: www.abb-control.com
Multifunction and Dedicated Time Delay Relays

Solid State Timing Modules and Flashers

Voltage Monitors and Phase Monitors

Current Sensors

Liquid Level Controls, Alternating Relays, and


Motor Winding Over Temperature Monitors

Tower and Obstruction Lighting Controls

Accessories
(Sockets, Mounting Methods, Adjustments,
Motor Protector, Liquid Level Probes and Holders)
TOC1pp
11.23.07

Application Notes, Glossary, and Index

Low Voltage Products & Systems 


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
KRPS Series Single Function
Time Delay Relay (10A SPDT) See the inside front cover for details

The KRPS Series is a factory programmed time delay relay available in any 1 of 14
functions and measures only 2 inches square. Modules are manufactured without the
function assigned. When an order is received, the function and time delay software are
added. This approach provides fast QuickShip delivery on all time ranges and functions.
Encapsulation protects against shock, vibration, and humidity. The KRPS Series is a cost
effective approach for OEM applications that require small size, isolation, accuracy, and
long life.
Choose from 1 of 14 standard single functions,
fixed or onboard or external adjustment, and 9 time
ranges. All available through the QuickShip program.
Code
Connection **Function Chart
Delay On Make M
US Patent 6708135
Delay On Break B
Recycle (ON Time First, Equal Times) RE
Recycle OFF Time First, Equal Times) RD
Single Shot S, SD
Choose 1 of 14 Standard Interval I
Functions
Trailing Edge Single Shot TS
Factory Programmed
Microcontroller Circuitry, Inverted Single Shot US
+/-0.5% Repeat Accuracy Inverted Delay On Break UB
Isolated 10 A SPDT Output Accumulative Delay on Make AM
Contacts Motion Detector / Retriggerable Single Shot PSD, PSE
Universal Voltage ! Shows alternate location Alternating Relay FT
24...240 V AC/DC of external adjust Flip Flop (leading edge) F
Delays from 100 ms...1000 h
in 9 Ranges V = Voltage C = Common, Transfer Contact See page 9 for function time diagrams
Onboard, External Adjust or NC = Normally Closed NO = Normally Open
Fixed Time Delay S1 = Initiate Switch UTL = Untimed Load

A knob is supplied for adjustable units, or RT terminals 4 & 5 for


external adjust. Select a 100K ohm potentiometer for full time
range adjustment. The untimed load is optional. S1 is not used
for some functions. Dashed lines are internal connections.

Technical Data
Output
Rating (at 40°C) 10 A resistive at 125 V AC
Accessories 5 A resistive at 230 V AC & 28 V DC
1/4 hp at 125 V AC
100K Ohm
Mechanical
External adjust
potentiometer Mounting Surface mt. with one #10 (M5 x 0.8) screw
P/Ns: Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
P1004-95 (fig A) Termination 0.25 in. (6.35 mm) male quick connects
P1004-95-X (fig B)

Versa-knob
P/N: P0700-7
Ordering Table
DIN rail P/Ns: KRPS X X X X
017322005 (Steel) Series Input Adjustment Time Delay* Function**
– A - 24 ... 240 V AC/DC – 1 - Fixed – 1 - 0.1 ... 10 s – Specify Function
← – D - 12 ... 48 V DC† – 2 - Onboard
Adjustment
– 2 - 1 ... 100 s
– 3 - 10 ... 1000 s
(Refer to Function
Chart for Code)
→ – 3 - External
Adjustment
– 4 - 0.1 ... 10 m
– 5 - 1 ... 100 m
DIN rail adaptor
P/N: P1023-20 – 6 - 10 ... 1000 m
Note: Grayed option is available in standard lead time.

– 7 - 0.1 ... 10 h * If Fixed Delay is selected, insert delay
– 8 - 1 ... 100 h [0.1 ... 1000] followed by (S) secs.,
See accessory pages
– 9 - 10 ... 1000 h (M) mins., or (H) hrs.
Example P/N:
KRPSA23RE = Universal AC/DC voltage, onboard adjustment, 10...1000 sec., recycling, ON time first
12.28.07

KRPSA10.5SI = Universal AC/DC voltage, fixed delay of 0.5 sec., interval function
KRPSpp

2 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
KRPD Series Dual Function
Time Delay Relay (10A SPDT) See the inside front cover for details

The KRPD Series is a factory programmed time delay relay available with 1 of
12 standard dual functions. Modules are manufactured without the function
assigned. When an order is received, the function and time delay software are
added. This approach provides Quick Ship delivery on all standard time ranges
and functions. Encapsulation protects against shock, vibration, and humidity.
The KRPD Series is a cost effective approach for OEM applications that require
small size, isolation, accuracy, and long life.

Choose from 1 of 12 standard single functions,


fixed or onboard adjustment and 9 time ranges.
All available through the Quick Ship program.

Connection **Function Chart Code

US Patent 6708135 Delay On Make/Delay on Break MB


Delay On Make/Recycle (ON Time First, Equal Times) MRE
Delay On Make/Interval MI
Delay On Make/Single Shot MS
Choose 1 of 12 Standard Interval/Recycle (ON Time First, Equal Times) IRE
Dual Functions Delay On Break/Recycle (ON Time First, Equal Times) BRE
Factory Programmed Single Shot/Recycle (ON Time First, Equal Times) SRE
Microcontroller Circuitry, Recycle (Both Times Adjustable, ON Time First) RXE
+/-0.5% Repeat Accuracy Recycle (Both Times Adjustable, OFF Time First) RXD
Isolated 10 A SPDT Interval/Delay On Make IM
Output Contacts Accumulative Delay On Make/Interval AMI
Universal Voltage Single Shot Lockout SL
24 ... 240 V AC/DC
Delays from 100 ms ...1000 h V = Voltage C = Common, Transfer Contact See page 10 for function time diagrams
in 9 Ranges NC = Normally Closed NO = Normally Open
S1 = Initiate Switch UTL = Optional Untimed Load

A knob is supplied for adjustable units. The untimed


load is optional. S1 is not used for some functions.
Dashed lines are internal connections.

Tehnical Data
Output
10 A resistive at 125 V AC
Rating (at 40°C) 5 A resistive at 230 V AC & 28 V DC
Mounting Accessory
1/4 hp at 125 V AC
Mechanical
DIN rail P/Ns:
Mounting Surface mount with one #10 (M5 x 0.8) screw
017322005 (Steel)
Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)

← Termination 0.25 in. (6.35 mm) male quick connects


DIN rail adaptor
P/N: P1023-20

Ordering Table
KRPD X X X X X X
Series Input First Adjustment First Time Delay* Second Adjustment Second Time Delay* Function**
(T1 or RT1) (T2 or RT2)
–A - 24 ... 240 V AC/DC –1 - Fixed –1 - 0.1 ... 10 s –1 - Fixed –1 - 0.1 ... 10 s – Specify Function
–D - 12 ... 48 V DC –2 - Onboard Adjust –2 - 1 ... 100 s –2 - Onboard Adjust –2 - 1 ... 100 s (Refer to Function
–3 - External Adjust –3 - 10 ... 1000 s –3 - External Adjust –3 - 10 ... 1000 s Chart for Code)
–4 - 0.1 ... 10 m –4 - 0.1 ... 10 m
–5 - 1 ... 100 m –5 - 1 ... 100 m
–6 - 10 ... 1000 m –6 - 10 ... 1000 m
Note: Grayed options are available in standard lead time.

–7 - 0.1 ... 10 h –7 - 0.1 ... 10 h
KRPDpp

–8 - 1 ... 100 h –8 - 1 ... 100 h


–9 - 10 ... 1000 h –9 - 10 ... 1000 h

Example P/N: *If Fixed Delay is selected, insert delay [0.1 ... 999] followed by (S) secs., (M) mins., or (H) hrs.
12.28.07

KRPDA2525MRE = Universal AC/DC voltage, onboard adjustment, T1=1...100 m, T2=1...100 m, delay on make /recycling - ON time first
KRPDD10.5S110SMB = Universal AC/DC voltage, fixed delays, T1= 0.5 sec., T2 = 100 sec. delay on make /delay on break

Low Voltage Products & Systems 3


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
KSPS Series Single Function
Timing Module (1A Solid State Output) See the inside front cover for details

The KSPS Series is a factory programmed module available in any 1 of 14 standard functions.
Modules are manufactured without the function assigned. When an order is received, the
function and time delay software are added. This approach allows QuickShip delivery on a
large number of part numbers. The 1 A steady, 10 A inrush rated solid state output provides
100 million operations typical. Encapsulation protects against shock, vibration, and humidity.
The KSPS Series is a cost effective approach for OEM applications that require small size and
solid state reliability.

Choose from 1 of 14 standard single functions, fixed or


onboard or external adjustment, and 9 time ranges. All
available through the QuickShip program.

US Patent 6708135
Connection **Function Chart Code

Delay on Make M
Delay on Break B
Choose 1 of 14 Standard Recycle (ON Time First, Equal Times) RE
Functions Recycle ( OFF Time First, Equal Times) RD
Factory Programmed Single Shot S, SD
Microcontroller Circuitry, Interval I
+/-0.5% Repeat Accuracy Trailing Edge Single Shot TS
Solid State Output 1 A Inverted Single Shot US
Steady, 10 A Inrush Inverted Delay on Break UB
Onboard, External Adjust or Accumulative Delay on Make AM
Fixed Time Delay Motion Detector/Retriggerable Single Shot PSD. PSE
Universal Voltage 24 ... 240 V AC Flip Flop (trailing edge, alternating) FT
Delays from 100 ms...1000 h Flip Flop (leading edge) F
in 9 Ranges See page 9 for function time diagrams

A knob is supplied for adjustable units, or RT terminals


4 & 5 for external adjustment. Select a 100K ohm
potentiometer for full time range adjustment. The untimed
load is optional. S1 is not used for some functions.
Dashed lines are internal connections.

Technical Data
Output
Accessories Rating 1 A steady, 10 A inrush for 16 ms
100 K Ohm Mechanical
External adjust Mounting Surface mt. with one #10 (M5 x 0.8) screw
potentiometer Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
P/Ns: Termination 0.25 in. (6.35 mm) male quick connects
P1004-95 (fig A)
P1004-95-X (fig B)

Versa-knob
06.11.08

P/N: P0700-7 Ordering Table


DIN rail P/Ns: KSPS X X X X
017322005 (Steel) Series Input Adjustment Time Delay* Function**
KSPSpp

– A - 24 ... 240 V AC – 1 - Fixed – 1 - 0.1 ... 10 s – Specify Function


← – P - 12 ... 120 V DC
Positive Switching
– 2 - Onboard
Adjustment
– 2 - 1 ... 100 s
– 3 - 10 ... 1000 s
(Refer to Function
Chart for Code)
→ – N - 12 ... 120 V DC
Negative Switching
– 3 - External
Adjustment
– 4 - 0.1 ... 10 m
– 5 - 1 ... 100 m
DIN rail adaptor
P/N: P1023-20 – 6 - 10 ... 1000 m

Note: Grayed options are available in standard lead time. – 7 - 0.1 ... 10 h * If Fixed Delay is selected, insert delay
– 8 - 1 ... 100 h [0.1 ... 1000] followed by (S) secs.,
– 9 - 10 ... 1000 h (M) mins., or (H) hrs.
See accessory pages Example P/N:
KSPSA23RE = Universal AC voltage, onboard adjustment, 10...1000 sec., recycling, ON time first
KSPSA10.5SI = Universal AC voltage, fixed delay of 0.5 sec., interval function

4 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
KSPD Series Dual Function
Timing Module (1A Solid State Output) See the inside front cover for details

The KSPD Series is a factory programmed module available with 1 of 6


standard dual functions. Modules are manufactured without the function
assigned. When an order is received, the function and time delay software are
added. This approach provides QuickShip delivery on all adjustment options
and time ranges. The solid state output provides 100 million operations,
typical. Encapsulation protects against shock, vibration, and humidity. The
KSPD Series is a cost effective approach for OEM applications that require
small size and long life.

Choose from 1 of 6 standard dual functions, fixed or onboard or


external adjustment, and 9 time ranges. All available through the
QuickShip program.

Connection **Function Chart Code


US Patent 6708135 Delay On Make/Recycle (ON Time First, Equal Times) MRE
Delay On Make/Interval MI
Interval/Recycle (ON Time First, Equal Times) IRE
Choose 1 of 6 Standard Recycle (Both Times Adjustable, ON Time First) RXE
Dual Functions Recycle (Both Times Adjustable, OFF Time First) RXD
Factory Programmed Interval/Delay On Make IM
Microcontroller Circuitry,
+/-0.5% Repeat Accuracy See page 10 for function time diagrams
1 A Steady, 10 A Inrush
Universal Voltage 24 ... 240 V AC
Delays from 100 ms ...1000 h
in 9 Ranges
Onboard, External Adjust or
Fixed Time Delay
Terminal Location for
External Adjustment.
V = Voltage T1 & RT1 = First Adjustment
L = Load T2 & RT2 = Second Adjustment

A knob is supplied for adjustable units or RT


Accessories terminals for external adjust. Use a 100 K ohm
potentiometer for full time range adjustment.
100 K Ohm Dashed lines are internal connections.
External adjust
potentiometer
P/Ns:
P1004-95 (fig A) Technical Data
P1004-95-X (fig B)
Versa-knob Output
P/N: P0700-7 Rating 1 A steady, 10 A inrush for 16 ms
Mechanical
DIN rail P/Ns: Mounting Surface mt. with one #10 (M5 x 0.8) screw
017322005 (Steel) Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination 0.25 in. (6.35 mm) male quick connects


DIN rail adaptor
P/N: P1023-20

See accessory pages

KSPD X X X X X X
Series Input First Adjustment First Time Delay* Second Adjustment Second Time Delay* Function**
–A - 24 ... 240 V AC –1 - Fixed (T1 or RT1) –1 - Fixed (T2 or RT2) - Specify Function
–P - 12 ... 120 V DC –2 - Onboard Adjust –1 - 0.1 ... 10 s –2 - Onboard Adjust –1 - 0.1 ... 10 s (Refer to Function
Positive Switching –3 - External Adjust –2 - 1 ... 100 s –3 - External Adjust –2 - 1 ... 100 s Chart for Code)
–N - 12 ... 120 V DC –3 - 10 ... 1000 s –3 - 10 ... 1000 s
Negative Switching –4 - 0.1 ... 10 m –4 - 0.1 ... 10 m
–5 - 1 ... 100 m –5 - 1 ... 100 m
KSPDpp


Note: Grayed options are available in standard lead time. –6 - 10 ... 1000 m –6 - 10 ... 1000 m *If Fixed Delay is selected,
–7 - 0.1 ... 10 h –7 - 0.1 ... 10 h insert delay [0.1 ... 999]
–8 - 1 ... 100 h –8 - 1 ... 100 h followed by (S) secs.,
Example P/N: –9 - 10 ... 1000 h –9 - 10 ... 1000 h (M) mins., or (H) hrs.
01.03.08

KSPDA2525MRE = 24...240V AC, onboard adjustment, T1=1...100 m, T2=1...100 m, delay on make /recycling - ON time first
KRPDD10.5S110SMB = 24...240V AC, fixed delays, T1= 0.5 sec., T2 = 15 sec. recycling - both times adjustable, ON time first.

Low Voltage Products & Systems 5


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
KSPU Series Single Timer or Counter Function
Timing Module (1A Solid State Output) See the inside front cover for details

Switch Adjustment
The KSPU Series is a factory programmed 1 amp solid
state module available in any 1 of 16 switch adjustable
timer or counter functions. Modules are manufactured
without the function assigned. When an order is
received, the function and time delay software are
added. This approach provides fast QuickShip delivery
on a large number of part numbers. Switch adjustment
allows accurate selection of the time delay or number
of counts the first time and every time. The solid state
output provides 100 million operations, typical. The
KSPU Series is a cost effective approach for OEM
applications that require small size, solid state reliability,
and accurate switch adjustment.
US Patent 6708135

One or more switches must be ON for proper operation.


Choose 1 of 16 Standard
**Function Chart Code
Functions Connection
Factory Programmed Delay on Make M
Microcontroller Circuitry, Delay on Break B
+/-0.1% Repeat Accuracy Recycle (ON Time First, Equal Times) RE
Solid State Output 1 A Recycle ( OFF Time First, Equal Times) RD
Steady, 10 A Inrush Single Shot S, SD
Accurate Switch Adjustment Interval I
Universal Voltage Trailing Edge Single Shot TS
24 ... 240 V AC Inverted Single Shot US
Delays from 100 ms...1023 h Inverted Delay on Break UB
in 6 ranges Accumulative Delay on Make AM
Counts to 1023 in 3 Ranges Motion Detector/Retriggerable, Single Shot PSD PSE
Counter/Pulsed Output C
Counter/Interval Output CI
Flip Flop (trailing edge, alternating) FT
Flip Flop (leading edge) F

V = Voltage S1 = Initiate Switch See page 9 for function time diagrams


L = Load UTL = Untimed Load
The untimed load is optional. S1 is not used for
some functions. Dashed lines are internal connections.

Technical Data
Count
Rate ≤ 25 counts per second
Output
Rating 1 A steady, 10 A inrush for 16 ms
Counter Output (P/N Variable 7 & 8) Output Pulse width: 300 ms +/-20%
Protection
Circuitry Encapsulated
Mechanical
Mounting Surface mt. with one #10 (M5 x 0.8) screw
Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Termination 0.25 in. (6.35 mm) male quick connects
Mounting Accessory
Ordering Table
DIN rail P/Ns: KSPU X X X
017322005 (Steel)
Series Input Time Delay/Counts Function**
← – A - 24 ... 240 V AC
– P - 12 ... 120 V DC
– 1 - 0.1 ... 102.3 s
– 2 - 1 ... 1023 s
– Specify Function
(Refer to Function
→ Positive Switching
– N - 12 ... 120 V DC
– 3 - 0.1 ... 102.3 m
– 4 - 1 ... 1023 m
Chart for Code)
DIN rail adaptor
01.07.08

P/N: P1023-20 Negative Switching – 5 - 0.1 ... 102.3 h


– 6 - 1 ... 1023 h
Note: Grayed option is available

–7- 1 ... 165 counts (straight) w/pulsed output
in standard lead time.
–8- 1 ... 1023 counts (binary) w/pulsed output
KSPUpp

See accessory pages


–9- 1 ... 7 counts to start 1 ... 63 s or m interval time
Example P/N:
KSPUA2RE = Universal AC voltage, switch adjustment, 1...1023 sec., recycling, ON first

6 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
HRPS/HRIS Series Single Function
Time Delay Relay (30A SPDT) See the inside front cover for details

The HRPS/HRIS Series combines a 30 amp rated electromechanical relay output with any 1
of 14 standard functions. Modules are manufactured without the function assigned. When
an order is received, the function and time delay software are added. This approach allows
Quick Ship delivery on all time ranges and functions The 30A res. output contact rating
allows for direct operation of heavy loads such as compressors, pumps, blower motors,
heaters, etc. This series is ideal for OEM applications where cost is a factor. HRPS has
non-isolated SPDT relay contacts, and HRIS has isolated SPDT relay contacts.

Choose from 1 of 14 standard single functions, fixed or


onboard or external adjustment, and 9 time ranges. All
available through the QuickShip program.

Connection **Function Chart Code


US Patent 6708135
Delay on Make M
Delay on Break B
Recycle (ON Time First, Equal Times) RE
Recycle ( OFF Time First, Equal Times) RD
HRPS Series Single Shot S, SD
30 A SPDT N.O. Output Contacts Relay contacts Interval I
Factory Programmed are not isolated. Trailing Edge Single Shot TS
Universal Voltage Inverted Single Shot US
24 ... 240 V AC ... 110 V DC Inverted Delay on Break UB
Encapsulated Circuitry Accumulative Delay on Make AM
Onboard, External Adjust or Motion Detector/Retriggerable Single Shot PSD. PSE
Fixed Time Delay Alternating Relay FT
Delays from 100 ms...1000 h Flip Flop (leading edge) F
in 9 ranges
+/-0.5% Repeat Accuracy See page 9 for function time diagrams

NOTE: A knob is supplied for adjustable units,


or RT terminals for 4 & 5 for external adjustment.
Select a 100K ohm potentiometer for full time range
adjustment. The untimed load is optional. S1 is not
HRIS Series used for some functions. Dashed lines are internal
Relay contacts connections.
are isolated.
V = Input Voltage S1 = Initiate Switch
C = Common UTL = Optional Untimed Load
NO = Normally Open NC = Normally Closed

Accessories
100 K Ohm Technical Data
External adjust
Output
potentiometer
P/Ns: Ratings: SPDT-N.O SPDT-N.C.
P1004-95 (fig A) General Purpose 125/240 V AC 30 A 15 A
P1004-95-X (fig B) Motor Load 125 V AC 1 hp* 1/4 hp**
240 V AC 2 hp** 1 hp**
Versa-knob Life Electrical -- 1 x 105, *3 x 104, **6,000
P/N: P0700-7 Mechanical
Mounting Surface mt. with one #10 (M5 x 0.8) screw
Package 3 x 2 x 1.5 in (76.7 x 51.3 x 38.1 mm)
Termination 0.25 in. (6.35 mm) male quick connects
DIN rail P/Ns:
017322005 (Steel) Ordering Table
HRPS/HRIS X X X X

→ Series Input Adjustment Time Delay * Function **
DIN rail adaptor –W - 24 ... 240 V AC –1 - Fixed –1 - 0.1 ... 10 s –Specify Function
P/N: P1023-20 24 ... 110 V DC –2 - Onboard Adjust –2 - 1 ... 100 s (Refer to Function
–D - 12 ... 48 V DC † –3 - External –3 - 10 ... 1000 s Chart for Code)
Adjust –4 - 0.1 ... 10 m
–5 - 1 ... 100 m
HRPSpp


Note: Grayed option is available in standard lead time. –6 - 10 ... 1000 m *If Fixed Delay is selected,
–7 - 0.1 ... 10 h insert delay [0.1 ... 1000]
–8 - 1 ... 100 h followed by (S) secs.,
Example P/N: –9 - 10 ... 1000 h (M) mins., or (H) hrs.
01.07.08

See accessory pages. HRPSW23S = Universal AC/DC voltage, onboard adjustment, 10...1000 sec., single shot function
HRISW10.5SB = Universal AC/DC voltage, isolated contacts, fixed delay of 0.5 sec., delay on break function

Low Voltage Products & Systems 7


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
HRPU/HRIU Series Single Function
Time Delay Relay (30A SPDT) See the inside front cover for details

Switch Adjustment
The HRPU/HRIU features a 30A rated electromechanical
relay output with any 1 of 16 standard switch adjustable
timer or counter functions. Its switching capacity allows
direct control of loads like compressors, pumps, motors,
heaters, and lighting. Modules are manufactured without the
function assigned. When an order is received, the function
and time delay software are added. This approach provides
Quick Ship delivery on a large number of part numbers.
Switch adjustment allows accurate selection of the time
delay or number of counts the first time and everytime.
The HRPU has non-isolated relay contacts, the HRIU has
isolated relay contacts. The HRPU/HRIU Series is a cost
US Patent 6708135 effective approach for OEM applications that require small
size, reliability and accurate switch adjustment.

One or more switches must be ON for proper operation.


Choose 1 of 16 Standard
Functions
Connection
**Function Chart Code
Factory Programmed
Microcontroller Circuitry, Delay on Make Timer M
+/-0.1% Repeat Accuracy Delay on Break Timer B
30 A, N.O. Output Contacts Recycle Timer (ON Time First, Equal Times) RE
Accurate Switch Adjustment Recycle Timer (OFF Time First, Equal Times) RD
24 ... 240 V AC; 24 ... 110 V DC HRIU Single Shot Timer S,SD
Delays from 100 ms ...1023 h Isolated Output Interval Timer I
in 6 Ranges Trailing Edge Single Shot Timer TS
L = Load Motion Detector/Retriggerable Single Shot PSD, PSE
Counts to 1023 in 3 Ranges
V = Voltage Inverted Single Shot Timer US
S1 = Initiate Switch* Accumulative Delay on Make Timer AM
UTL = Optional Untimed Load Inverted Delay on Break Timer UB
Counter/Pulsed Output C
Counter/Interval Output CI
Flip Flop (Trailing Edge, Alternating) FT
Flip Flop (Leading Edge) F
See page 9 for function time diagrams

HRPU
Non-Isolated Output
*Note: S1 is not used for some functions.
Dashed lines are internal connections.
Technical Data
Count
Rate ≤ 25 counts per second
Output
Ratings: Voltage SPDT-N.O. SPDT-N.C.
General Purpose 125/240 V AC 30 A 15 A
Motor Load 125 V AC 1 hp* 1/4 hp**
240 V AC 2 hp** 1 hp**
Life Electrical -- 1 x 105, *3 x 104, ** 6,000
Counter Output (P/N Variable 7 & 8) Output Pulse width 300 ms +/- 20%
Mechanical
Mounting Surface mt. with one #10 (M5 x 0.8) screw
Termination 0.25 in. (6.35 mm) male quick connects
Package 3 x 2 x 1.5 in.(76.7 x 51.3 x 38.1mm)
Mounting Accessory
Ordering Table
HRPU/HRIU X X X
Series Input Time Delay/Counts Function**
–W - 24 ... 240 V AC –1 - 0.1 ... 102.3 s – Specify Function
DIN rail P/Ns: 24 ... 110 V DC –2 - 1 ... 1023 s (Refer to Function
017322005 (Steel) –D - 12 ... 48 V DC –3 - 0.1 ... 102.3 m Chart for Code)
–4 - 1 ... 1023 m

01.08.08

–5 - 0.1 ... 102.3 h


→ Note: Grayed option is available

in standard lead time. –6 - 1 ... 1023 h


DIN rail adaptor
–7 - 1 ... 165 counts (straight) w/pulsed output
P/N: P1023-20
–8 - 1 ... 1023 counts (binary) w/pulsed output
HRPUpp

Example P/N: –9 - 1 ... 7 counts to start 1 ... 63 s or m interval time


See accessory pages
HRPUW2S = Universal AC/DC voltage, switch adjustment, 1...1023 sec., single shot function
HRIUW3B = Universal AC/DC voltage, isolated relay contacts, switch adjustment,0.1...102.3 min., delay on break function

8 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
Function Selector
For KRPS, KSPS, KSPU, HRPS, HRPU, HRIU
Single Adjustment Functions See the inside front cover for details

Function Diagrams

M Delay On Make S Single Shot AM Accumulative Delay On Make

I Interval

SD Operates same as S except will not energize FT Alternating Relay


and start timing if initiate switch is closed
when input voltage is applied.

TS Trailing Edge Single Shot

RE Recycling (ON First)

F Leading Edge Flip-Flop

Motion Detector
RD Recycling (OFF First) PSD Retriggerable Single Shot

C Counter with Pulsed Output

B Delay On Break Motion Detector (PSE)


PSE
Retriggerable Single Shot

CI Counter with Interval Output


UB Inverted Delay On Break US Inverted Single Shot

Legend
V = Voltage R = Reset S1 = Initiate Switch
TD1, TD2 = Time Delay C = Count
P = Pulse Duration t = Incomplete Time Delay
NO = Normally Open NC = Normally Closed
= Undefined time

Note: If S1 is closed when input voltage is


KRPSpp

applied, the function starts and the time delay


begins. (B, S, TS, US, UB, AM, PSD, FT)
01.04.08

Low Voltage Products & Systems 


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
Function Selector
For KRPD, KSPD Series
Dual Adjustment Functions See the inside front cover for details

Function Diagrams

RXE Recycle MI Delay On Make IM Interval


Both Times Adjustable Interval Delay On Make
(ON Time First)

AMI Accumulative Delay On Make


RXD Recycle Interval BRE Delay On Break
Both Times Adjustable Recycle
(OFF Time First)

MS Delay On Make SL Single Shot Lockout


MB Delay On Make Single Shot
Delay On Break

SRE Single Shot


MRE Delay On Make IRE Interval Recycle
Recycle Recycle

Legend
V = Voltage R = Reset S1 = Initiate Switch
TD1, TD2 = Time Delay t = Incomplete Time Delay
NO = Normally Open NC = Normally Closed
Undefined time

Note: If S1 is closed when input voltage is


applied, the function starts and the time delay
begins. (MB, MS, BRE, SRE, AMI, SL)
01.04.08
KRPDpp

10 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
n Multifunction, Multirange
c tio
n
ifu rs TRU Series, Knob Adjustable
ult ime
M t
Universal Time Delay Relay

The TRU Series is a multifunction, Function


knob adjustable, universal
time delay relay. As a universal
replacement part, it can reduce
inventory costs; replacing up to
1000 competitive time delay relay
part numbers.

Knob adjustment of the time delay


Easy, fast slide switch selection of 1
of 6 of the most popular functions
Positive switch selection of the time
range and seconds or minutes.

Universal
Replacement
Multifunction and Multirange Part
Replaces up to
Six Timing Functions are 1000
Switch Selectable part numbers
0.1 s ... 1000 m in Six Ranges
Knob Adjustable Time Delay Connection
Microcontroller +/-0.1%
Repeat Accuracy
Universal Input Voltage
19...264 V AC & 19...30 V DC
10 A, SPDT or DPDT
Relay Contacts
2 LED Status Indicators

8 Pin DPDT 8 Pin SPDT

A six position slide switch selects


the function. 8 Pin DPDT base
wiring has 3 popular functions. All
six functions are available in the 8
pin SPDT and 11 pin DPDT versions.
3 Popular Functions:
• Delay On Make V = Voltage S1 = Initiate Switch
• Interval R = Reset TD = Time Delay
• Recycling NO = Normally Open Contact
t = Incomplete Time Delay
Mounting and Connection 11 Pin DPDT
Accessory Dashed lines are internal connections.
Relay contacts are isolated.
Octal Technical Data
8 pin socket
P/N: NDS-8 Time Delay
0.1 s ... 1000 m in 6 ranges--0.1 ... 10, 1 ... 100 or
Range: Switch Selectable
10 ... 1000 s; 0.1 ... 10, 1 ... 100 or 10 ... 1000 m
Adjustments – Multiplier: 4 position DIP switch selects x0.1, x1, x10, and s or m
– Time Setting: Onboard knob adjustment with 1 ... 100 reference dial
35mm DIN Repeat Accuracy +/- 0.1% or +/-20 ms, whichever is greater
Rail or Surface Output
Mounting Rating 10 A resistive at 120/240 V AC & 28 V DC; 1/3 hp at 120/240 V AC
Mechanical
Octal Package 3.44 x 2.39 x 1.78 in. (87.3 x 60.7 x 45.2 mm)
11 pin socket Mounting Surface or 35mm DIN rail, requires accessory 8 or 11 pin socket
P/N: NDS-11
Ordering Table
Part Number Voltage Functions Connection
TRU1pp

TRU1 3 8 pin DPDT


19 ... 264 V AC;
TRU2 6 8 pin SPDT
19 ... 30 V DC
See accessory pages TRU3 6 11 pin DPDT
01.04.08

Low Voltage Products & Systems 11


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
ion Multifunction Multirange
n ct y
ifu ela TRDU Series Switch Adjustable
ult e D y
M im la
T Re Time Delay Relay (10A SPDT or DPDT)
Single Functions
* Delay On Make

Dual ON
Functions M
Replace up
to 3 Separate ABCDE
Timers
Delay On Break

ON
B

ABCDE
* Recycle
(ON Time First, Equal Delays)

ON
Multifunction – 21 Timing RE
Functions
Multirange – 0.1 s ... 1,705 h Universal ABCDE
in 8 Ranges Replacement
Part Single Shot
Switch Selectable Function, Replaces up to
Time Delay, & Ranges 100
Microcontroller +/-0.1% The TRDU Series is a versatile part numbers
universal time delay relay with ON
Repeat Accuracy S
24 or 120V AC; 24 V DC twenty-one switch selectable
Input Voltages single and dual functions. The
ABCDE
10 A, Isolated SPDT or DPDT dual functions replace up to three
timers required to accomplish the * Interval
Output Contacts
same function. The TRDU replaces
hundreds of part numbers, thereby, ON
reducing your inventory cost.

Connection ABCDE

8 Pin DPDT 8 Pin SPDT 11 Pin DPDT V = Voltage S1 = Initiate Switch


NO = Normally Open
NC = Normally Closed

Relay contacts are isolated.


Dashed lines are internal connections.

Mounting and Connection Technical Data


Accessory Time Delay
Range: Switch Selectable Single Functions: 0.1 s ... 1,705 h in 8 ranges
Octal
8 pin socket Dual Functions: 0.1 s ... 3,100 m each in 8 ranges
P/N: NDS-8 Adjustments Three switches are provided to set secs/mins & multipliers of x0.1, x1, x10, or x100
Repeat Accuracy +/-0.1% or 20 ms, whichever is greater
Timing Functions Five switches are provided to set one of twenty-one single or dual functions
Output
Rating 10 A resistive at 120/240 V AC & 28 V DC; 1/3 hp at 120/240 V AC
Mechanical
35mm DIN Package 3.1 x 2.39 x 1.78 in. (78.7 x 60.7 x 45.2 mm)
Rail or Surface Mounting Surface or 35mm DIN rail, requires accessory 8 or 11 pin socket
Mounting

Octal
11 pin socket Ordering Table
P/N: NDS-11
Part Number Input Voltage Base Connection
TRDU24A2 8 Pin SPDT
24 V AC/DC
01.16.08

TRDU24A3 11 Pin DPDT


TRDU120A1 8 Pin DPDT
TRDU120A2 120 V AC 8 Pin SPDT
See accessory pages TRDU120A3 11 Pin DPDT
TRDU1pp

12 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
n
c tio Multifunction, Multirange
n y
ifu ela TRDU Series Switch Adjustable
ult e D y
M im la
T Re Function Diagrams
Single Functions Dual Functions (continued)
Trailing Edge
Delay On Make
Single Shot
Single Shot
ON
TS ON
MS
ABCDE
ABCDE
Inverted * Interval
Single Shot Recycle (ON Time First)

ON ON
US IRE

ABCDE ABCDE

Inverted Delay On Break


Delay On Break Recycle (ON Time First)

ON ON
UB BRE

ABCDE ABCDE

Single Shot
Retriggerable
Recycle (ON Time First)
Single Shot
ON ON
PS SRE

ABCDE ABCDE

* Recycle (ON Time First)


Accumulative
Both Times Adjustable
Delay On Make
ON
ON RXE
AM
ABCDE
ABCDE

Dual Functions
* Recycle (OFF Time First)
Delay On Make Both Times Adjustable
Delay On Break
ON
ON RXD
MB
ABCDE
ABCDE

* Delay On Make * Interval


Recycle (ON Time First) Delay On Make
ON
MRE ON
IM
ABCDE
ABCDE

* Delay On Make
Interval Accumulative Delay on Make
ON Interval
MI
ON
AMI
ABCDE
ABCDE
Key
5 Switches for Function Selection * 9 Functions included in the 8 pin DPDT models
3 Switches for Time Delay Range
V = Voltage R = Reset
TRDUFpp

OM =
D Delay On Make S1 = Initiate Switch TD,TD1,TD2 = Complete Time Delay
DOB = Delay On Break NC = Normally Closed Contact NO = Normally Open Contact
REC = Recycle t = Partial Time Delay = Undefined time
SS = Single Shot
01.02.08

INT = Interval NOTE:


M = Minutes The time delay range is the same for both functions when dual
S = Seconds functions are selected.

Low Voltage Products & Systems 13


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
ela
y Dedicated Timers
D
e lay TDM, TDI, TDS, TDB Digi-Set Series
Tim Re
Time Delay Relay

Digi-Set Binary Switch Operation Functions

Delay on Make

* The selected time


delay is the sum
of the delays of
all switches in the
* * *
ON position

Interval
The TD Series of time delay relays are our most popular series; providing
accurate and reliable performance with a 10 year warranty. The delay is
adjusted by ten binary DIP switches, which allow selection of the time
delay the first time and every time.

Single Function Timers Connection


Switch Settable Time Delays A B
+/-0.1% Repeat Accuracy
Delays from 100 ms ... 2.8 h
in 3 Ranges
AC and DC Input Voltages
Isolated 10 A Relay Contacts
Plug-In Connection & Mounting Single Shot
LED Indication

Relay contacts are isolated. 8 Pin Octal


Dashed lines are internal connections. SPDT

Technical Data
Delay on Break
Time Delay
0.1 ... 102.3 s in 0.1 s increments
Ranges 1 ... 1023 s in 1 s increments
10 ... 10,230 s in 10 s increments
Repeat Accuracy +/- 0.1% or 20 ms, whichever is greater
Mounting and Connection
Indication
Accessory
Indicator LED glows during timing; relay is energized
Octal S1 = Initiate Switch V = Voltage R = Reset
Output
8 pin socket 10 A resistive at 120/240 V AC & 28 V DC; NO = Normally Open NC = Normally Closed
Rating
P/N: NDS-8 1/3 hp at 120/240 V AC TD = Time Delay
Mechanical
Package 3.2 x 2.4 x 1.8 in. (81.3 x 60.7 x 45.2 mm)
Mounting Requires accessory 8 pin (Octal) socket

35mm DIN 10.20.08


Rail or Surface
Ordering Table
Mounting Part Number Voltage Function Time Range Connection
TDB120AL Delay on Break B
TD1pp

TDI120AL Interval 1 ... 1023 s A


TDM120AL Delay on Make A
120 V AC
TDML120AL Delay on Make 0.1 ... 102.3 s A
TDMH120AL Delay on Make 10 ... 10230 s A
See accessory pages TDS120AL Single Shot B
TDB24AL Delay on Break B
24 V AC 1 ... 1023 s
TDM24AL Delay on Make A
TDM12DL Delay on Make A
12 V DC
TDML12DL Delay on Make 0.1 ... 102.3 s A

Call for 230 V AC, 110 V DC and combinations not listed

14 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
Dedicated Timers
e lay
e D lay TDR Recycling / CT-ERD Delay on Make Timers
Tim Re Time Delay Relays
Function
TDR Series - Plug-in Digi Set Recycling Timer
The TDR Series is and octal plug-in recycling time delay relay with full
10A DPDT contacts. It provides separate adjustment of ON and OFF time
delays with two ten position DIP switches. Switch adjustment ensures
accurate adjustment of the time delay the first time and every time. An
accessory 8 pin socket required for mounting and connection.
(see accessory pages)
V = Voltage R = Reset T1 = ON Time
Technical Data T2 = OFF Time NO = Normally Open
NC = Normally Closed
Output
10 A resistive at 120/240 V AC & 28 V DC; Connection
Rating
1/3 hp at 120/240 V AC
Mechanical
Package 3.2 x 2.39 x 1.78 in. (81.3 x 60.7 x 45.2 mm)
Switch Settable Time Delays -
Mounting and Connection Surface or 35mm DIN rail mounting
Both Times Adjustable
0.1 s ... 2.8 h in 3 Ranges
+/-0.1% Repeat Accuracy
+/-2% Setting Accuracy Relay contacts are isolated.
10 A DPDT Isolated Relay Dashed lines are internal connections.
Contacts Ordering Table
Octal Plug-in Base
Connection TDR X X X X
Series Input Sequence ON Time OFF Time
–A - 24... 240 V AC/DC –A - ON Time First –1 - 0.1...102.3 s in –1 - 0.1...102.3 s in
–D - 12... 48 V DC –B - OFF Time First 0.1 s increments 0.1 s increments
–1 - 12 V DC –2 - 1...1023 s in –2 - 1...1023 s in
–2 - 24 V AC 1 s increments 1 s increments
–3 - 24 V DC –3 - 10...10,230 s in –3 - 10...10,230 s in
–4 - 120 V AC 10 s increments 10 s increments
–5 - 110 V DC NOTE: Options A & D qualify for Quickship delivery;
–6 - 230 V AC grayed options require standard lead time.

Example P/N: TDRAA12 = 24-240V, ON time first, 0.1 to 102.3 s ON time; 1 to 1023 s OFF time
TDRDB21 = 12-48V DC; OFF time first, 1 to 1023 s ON time, 0.1 to 102.3 s OFF time

CT-ERD - 17.5 mm, 35 mm DIN Rail Mount, Delay on Make Timer


The CT-ERD series provides more load switching capacity, 6 amp, in a thinner 35mm DIN mount
package. Timing begins when control supply voltage is applied. The green LED flashes during timing.
When the time delay is complete, the output relay energizes and the green LED glows. If control supply
voltage is interrupted, the output relay de-energizes and the time delay is reset.

1 Time Range Selector Switch Function


2 LEDs for Status Indication
U - Green LED: Control Supply Voltage
Applied & timing
R - Yellow LED: Output Relay Energized
3 Time Delay Adjustment
Delay on Make, (ON delay)
Function 4 Space Saving Package
TDR1pp

7 Time Ranges 0.05 s ... 100 h


SPDT (c/o) Relay Contact
2 LED Indicators
10.07.08

Universal Voltage
24 ... 240 V AC; ... 48 V DC Technical Data
6A SPDT (c/o) Contact 1.) 0.05-1 s
4.) 0.5-10 min 6.) 0.5-10 h
Connection Time Ranges 7 time ranges 0.05 s - 100 h 2.) 0.5-10 s
5.) 5-100 min 7.) 5-100 h
3.) 5-100 s
A1 15
Output
A1 15
AC12 (resistive) at 230 V 6A
AC15 (inductive) at 230 V 3A
Mechanical Dimensions (W x H x D) 17.5 mm x 70 mm x 58 mm (0.69 x 2.76 x 2.28 inches)
A2 16 18 Mounting DIN3 rail, snap-mounting (no tools required)
Protection enclosure / terminals IP50 / IP20
18 16 A2
Ordering Table
A1-A2 – Supply Voltage
15-16/18 – Isolated SPDT Series Part Number Voltage
(c/o) Contacts
CT-ERD.12 1SVR 500 100 R0000 24-48 V DC, 24-240 V AC

Low Voltage Products & Systems 15


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
ela
y Multifunction Timers
D
e lay CT-MFD Series DIN Rail Mounting
Tim Re
Time Delay Relay SPDT (c/o) or DPDT (2 c/o)

1 Time Range Selection The CT-MFD is a universal voltage, multifunction, DIN rail mount,
2 LEDs for Status Indication SPDT or DPDT time delay relay. It includes 7 switch selectable
U - Green LED: popular functions and 7 switch selectable time delay ranges. The time
delay is adjustable with an onboard trimmer. Featuring fast installation
Input Voltage Applied in control panels; snap onto DIN 3 rail and connect with IP20 screw
terminals. LED indication shows input voltage applied, timing, and
Timing output energized.
R - Yellow LED:

Output Relay Energized Switch Selectable Time Ranges:


3 Time Delay Adjustment 1 ..... 0.05-1 s
4 Function Selector 2 ..... 0.5-10 s
5 SPDT or DPDT (2 c/o) Contacts 3 ..... 5-100 s
6 IP20 Screw Terminals 4 ..... 0.5-10 min
7 Space Saving Package 5 ..... 5-100 min
CT-MFD.12 6 ..... 0.5-10 h
7 ..... 5-100 h

Function Selection Chart (see time diagrams)


1 ...... Delay on Make (ON-delay)
2 ......Interval (Impulse ON)
3 ......Flasher/Recycling ON First
4 ......Flasher/Recycling OFF First
5 ......Delay on Break (OFF-delay)
6 ......Single Shot (Pulse Former)
7 ......Trailing Edge Interval (Impulse OFF)
Connection
CT-MFD.21
A1 15 Y1/B1 A1 15 25

Y1/ Y1/
B1 A1 15 B1 A1 15 25
7 Switch Selectable Functions
7 Switch Selectable Time
Ranges (0.05 s...100 h)
SPDT or DPDT (2 c/o) contacts
A2 16 18 A2 16 18 26 28
Universal Voltage 12...240V AC/
DC; 3 Ranges 18 16 Y1/B1
Status Indication - 2 LEDs 18 16 A2
28 26 A2

CT-MFD.12 CT-MFD.21
A1-A2 Input Voltage: A1-A2 Input Voltage:
24-48 V DC or 12-240 V AC/DC
24-240 V AC 15-16/18 1 SPDT (c/o) Contact
15-16/18 1 SPDT (c/o) Contact 25-26/28 1 SPDT (c/o) Contacts
A1-Y1/B1 Initiate Switch S1 Input A1-Y1/B1 Initiate Switch S1 Input

Technical Data

Timing CT-MFD.12 CT-MFD.21


Repeat Accuracy (constant parameters) < +/- 0.5%
Mechanical
Dimensions (W x H x D) .69 x 2.76 x 2.28 in. (17.5 x 70 x 58 mm) .69 x 3.15 x 2.28 in (17.5 x 80 x 58 mm)
Mounting 35mm DIN Rail, No Tools Required
Degree of Protection Enclosure IP50 Terminals IP20

Ordering Table

Series Part Number Input Voltage Output Form Output Rating (res./ind.)
CT-MFD.12 1SVR 500 020 R0000 24-48 V DC, 24-240 V AC SPDT (c/o) 6A / 3A
01.17.08

CT-MFD.21 1SVR 500 020 R1100 12-240 V AC/DC DPDT (2 c/o) 5A / 2A


MFDpp

16 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
ion
Multifunction Timers
ct ms
n
Fu gra CT-MFD Series
a
Di Function Diagrams

CT-MFD Function Diagrams

Legend
V = Voltage NO = Normally Open
TD = Time Delay NC = Normally Closed
R = Reset S1 = Initiate Switch
t = incomplete TD = Undefined Time
MFDFpp
01.08.08

Low Voltage Products & Systems 17


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
ela
y Multifunction Timers
D
e lay CT-MVS Series
Tim Re
Relay Output, 22.5 mm, 35 mm DIN Rail Mount

1 Selectable Instantaneous or Description


Timed SPDT (c/o) Contact
2 Time Range Selection Multi-function timer, 22.5 mm width on Din Rail, 11 selectable
3 LEDs for Status Indication functions, 10 selectable time ranges, universal input voltage
U/T - Green LED: of 24 to 240 V AC and DC. Screwdriver adjustable time delay
and switch selectable function and time range. Select output
Input Voltage Applied as either DPDT (2 c/o) timed contacts or SPDT (c/o) timed
and SPDT (c/o) instantaneous contact. The time delay can
Timing be externally adjusted by connecting an accessory 50K ohm
R1 / R2 - Yellow LED: potentiometer.

R1 / R2 Relay Output Energized Switch Selectable Time Ranges:


4 Time Delay Adjustment 1 ..........0.05-1 s
5 Function Selector 2 ..........0.15-3 s
6 IP20 Screw Terminals 3 ..........0.5-10 s
22.5mm 7 Compact Package 4 ..........1.5-30 s
5 ..........5-100 s
6 ..........15-300 s
7 ..........1.5-30 min
Multifunction 10 Selectable 8 ..........15-300 min
Functions 9 ..........1.5-30 h
10 Switch Selectable Time 10 ..........15-300 h
Connection
Ranges (0.05 s...300 h)
2 SPDT (2 c/o) contacts Function Selection Chart (see time diagrams)
A1 15 25 21 A1-A2 Input Voltage:
Selectable Instantaneous 1 – Delay on Make (ON-delay)
Y1/B1 Z2 Z1 24-240 V AC/DC
Contact 2 – Interval (Impulse ON)
15-16/18 1 SPDT (c/o) Contact
Universal Voltage 24...240V Y1/ 25 3 – Flasher/Recycling ON or OFF First
B1 A1 15 25-26/28 1 SPDT (c/o) Contact
AC/DC 21
4 – Delay on Break (OFF-delay)
21-22/24 1 SPDT (c/o) as an
Status Indication - 3 LEDs 5 – Trailing Edge Interval (Impulse OFF)
Instantaneous Contact
A1-Y1/B1 Initiate Switch S1 Input 6 – Star Delta Starting (Interval/ON Delay)
Z1-Z2 Remote Potentiometer 7 – Delay on Make / Delay on Break (ON-delay / OFF-delay)
A2 16 18 26 28 Connection 8 – Single Shot (Pulse Former)
22 24
9 – Accumulative Delay on Make (ON-delay)
28 24 26 22 10 – ON/OFF Test Function without time delays
18 16 A2

Technical Data
Timing
Repeat Accuracy (constant parameters) < +/- 0.2%
Output
AC12 (resistive) at 230 V 4A
AC15 (resistive) at 230 V 3A
Mechanical
Dimensions (W x H x D) .89 x 3.07 x 3.94 in. (22.5 x 78 x 100 mm)
Mounting 35mm DIN Rail, no tools required
Degree of Protection Enclosure IP50 Terminals IP20

Ordering Table
Series Part Number Input Voltage
CT-MVS.21 1SVR 630 020 R0200 24-240 V AC/DC
01.10.08
MVSpp

18 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
ion
Multifunction Timers
ct ms
n
Fu gra CT-MVS Series
a
Di Function Diagrams

CT-MVS Function Diagrams

Legend
V = Voltage NO = Normally Open
TD = Time Delay NC = Normally Closed
R = Reset S1 = Initiate Switch
T1 = First Delay T2 = Second Delay = T1
TP = 50ms Pause Delay t = Incomplete Time Delay
R1 = Wye Start Relay R2 = Delta Run Relay
= Undefined Time
MVSFpp
01.18.08

Low Voltage Products & Systems 19


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
ela
y OFF Delay Timers
D
e lay CT-AHD and CT-ARS Series
Tim Re
Relay Output, 35mm DIN Rail Mounting

CT-AHD - 17.5mm, DIN Rail Mounting, Delay on Break Timer

1 LEDs for Status Indication Connection


U - Green LED: A1 15 Y1/B1
CT-AHD.12
Y1/
A1-A2 Input Voltage:
Input Voltage Applied B1 A1 15 24-48 V DC
24-240 V AC
Timing 15-16/18 SPDT (c/o) Contact
R / R1 / R2 - Yellow LED: A1-Y1/B1 Initiate Switch
A2 16 18
Output Relay Energized 18 16 A2
2 Time Range Selection
3 Time Delay Adjustment
4 SPDT (c/o) Contact
5 IP20 Screw Terminals Function
CT-AHD.12 6 Space Saving Package

Switch Selectable Time Ranges:


Delay on Break (OFF delay) 1...... 0.05-1 s 5...... 5-100 min
Function 2...... 0.5-10 s 6...... 0.5-10 h
7 Switch Selectable Time 3...... 5-100 s 7...... 5-100 h
Ranges (0.05 s...100 h) 4...... 0.5-10 min
SPDT ( c/o) contact
Universal Voltage Technical Data
24...240V AC; ...48V DC Timing
Status Indication - 2 LEDs Repeat Accuracy (constant parameters) < +/- 0.5%
Mechanical
Dimensions (W x H x D) .69 x 2.76 x 2.28 in. (17.5 x 70 x 58 mm)
Mounting 35mm DIN Rail, No Tools Required
Degree of Protection Enclosure IP50 Terminals IP20

Ordering Table
Series Part Number Input Voltage Output Rating (res./ind.)
CT-AHD.12 1SVR 500 110 R0000 24-48 V DC, 24-240 V AC 6A / 3A

CT-ARS - 22.5mm, DIN Rail Mounting, True Delay on Break Timer


1 LEDs for Status Indication Connection
U - Green LED:
A1 15 25 CT-ARS.22
Input Voltage Applied A1-A2 Input Voltage:
A1 15 25 24-48 V DC
Timing 24-240 V AC
R / R1 / R2 - Yellow LED: 15-16/18 SPDT (c/o) Contact
25-26/28 SPDT (c/o) Contact
A2 16 18 26 28
Output Relay Energized
2 Time Range Selection 28 26
3 Time Delay Adjustment 18 16 A2
4 DPDT (2 c/o) Relay Contacts
5 IP20 Screw Terminals
CT-ARS.22 6 Compact Package Function

06.11.08
True Delay on Break Function
Operates on Loss of Power Switch Selectable Time Ranges:
7 Switch Selectable Time 1....... 0.05-1 s 5....... 5-100 s
Ranges (0.05 s...10 m) 2....... 0.15-3 s 6....... 15-300 s
DPDT (2 c/o) contacts 3....... 0.5-10 s 7....... 0.5-10 min
ARSpp

Universal Voltage 4....... 1.5-30 s


24...240V AC; ...48V /DC
Status Indication - 2 LEDs Technical Data
Timing
Repeat Accuracy (constant parameters) < +/- 0.2%
Typical Charge Time 200 ms
Initial Charge Time 5 min.
Mechanical
Dimensions (W x H x D) .89 x 3.07 x 3.94 in. (22.5 x 78 x 100 mm)
Mounting 35mm DIN Rail, No Tools Required
Degree of Protection Enclosure IP50 Terminals IP20

Ordering Table
Series Part Number Input Voltage
CT-ARS.21 1SVR 630 120 R3300 24-48 V DC, 24-240 V AC

20 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
ing s Accurate General Purpose Timers
m
T dule
i
o KSD1, KSD2, KSDB, KSDS Series
M
Solid State Output Timing Modules

Connection These timing modules are designed for general purpose commercial and
KSD1 industrial applications where a small, cost effective, reliable solid state timer
KSD1 is required. The output is rated 1 A steady and 10 A inrush typically provides
100 million operations. The modules are totally solid state and encapsulated to
protect the electronic circuitry.
Function
Load may be KSD1
connected to
terminal 3 or 1.

A knob is supplied KSD2


KSD2 for adjustable units,
or RT terminals for
KSD2 4 & 5 for external
adjustment. Select
a 100K ohm
potentiometer for
full time range KSDB
adjustment. The
untimed load UTL
is optional. Dashed
lines are internal
connections.
KSDB, KSDS
KSDS

KSDB
KSDS

V = Voltage L = Load S1 = Initiate Switch


R = Reset TD = Time Delay
t = Incomplete Time Delay
Technical Data
Output
Maximum Load Current 1 A steady state, 10 A inrush at 60°C
Adjustable Delays from Minimum Holding Current (KSD1 only) ≤ 40 mA
0.1 s ... 10 min in 3 Ranges (KSD1 only) 7 mA at 230 V AC
OFF State Leakage Current
+/-0.5% Repeat Accuracy (all others) 5 mA at 230 V AC
+/-5% Factory Calibration Mechanical
1 A Solid State Output Mounting Surface mount with one #10 (M5 x 0.8) screw
Encapsulated Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Ordering Table Termination 0.25 in. (6.35 mm) male quick connect terminals

Part Number Time Delay Adjustment Function Voltage Accuracy


KSD1420 0.1...10 S 0.5% or 20mS
KSD1421 1…100 S External
0.5%
KSD1423 0.1...10 M Delay on Make
Accessories KSD1430 0.1...10 S (ON delay) 0.5% or 20mS
100 K Ohm
External adjust
KSD1431 1…100 S Onboard Adjust
0.5%
potentiometer KSD1433 0.1...10 M
P/Ns: KSD2420 0.1...10 S 0.5% or 20mS
P1004-95 (fig A) KSD2421 1…100 S External
P1004-95-X (fig B) 0.5%
KSD2423 0.1...10 M Interval
Versa-knob KSD2430 0.1...10 S (Single pulse) 0.5% or 20mS
P/N: P0700-7 KSD2431 1…100 S Onboard Adjust
0.5%
KSD2433 0.1...10 M
120 V AC
KSDB420 0.1...10 S 0.5% or 20mS
KSDB421 1…100 S External
0.5%
KSDB423 0.1...10 M Delay on Break
DIN rail P/Ns: KSDB430 0.1...10 S (OFF delay) 0.5% or 20mS
017322005 (Steel) KSDB431 1…100 S Onboard Adjust
0.5%
KSD1pp

KSDB433 0.1...10 M
← KSDS420 0.1...10 S 0.5% or 20mS
→ KSDS421 1…100 S External
0.5%
KSDS423 0.1...10 M Single Shot
12.28.07

DIN rail adaptor


P/N: P1023-20 KSDS430 0.1...10 S (One shot) 0.5% or 20mS
See accessory pages KSDS431 1…100 S Onboard Adjust
0.5%
KSDS433 0.1...10 M

Low Voltage Products & Systems 21


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
al s
v e rs ule
d Delay On Make
i o
Un g M TDU / TMV Series
in
Tim Universal Voltage Solid State Timing Modules

TDU Series - Switch Adjustable, Universal Voltage Timers


Digi-Set Binary Switch Operation The TDU is an encapsulated solid state delay on make timer that
combines digital timing circuitry with universal voltage operation.
It offers DIP switch adjustment allowing accurate selection of the
time delay over the full time delay range. Encapsulation protects
against humidity, vibration, and dust making it suitable for outdoor
equipment installations. This series is an excellent choice for OEM
equipment where fast, positive adjustment, low cost and long life
are important..

Ordering Table
2 Universal Voltage Ranges
From 24 ... 240 V AC/DC Part Number Input Voltage Time Range (seconds) Repeat Accuracy Tolerance
Switch Selectable Delays TDUL3000A 24 ... 120 AC/DC 0.1 ... 102.3
From 0.1 s ... 2.8 h in 3 TDUL3001A 100 ... 240 AC/DC 0.1 ... 102.3
Ranges or Factory Fixed
TDU3000A 24 ... 120 AC/DC 1 ... 1023 +/-0.5% or 20 ms
+/-0.5% Repeat Accuracy +/-10%
TDU3001A 100 ... 240 AC/DC 1 ... 1023 whichever is greater
1 A Steady - 10 A Inrush
Totally Solid State and TDUH3000A 24 ... 120 AC/DC 10 ... 10230
Encapsulated TDUH3001A 100 ... 240 AC/DC 10 ... 10230

Specifications for TDU and TMV


Function - TDU / TMV
Operation - TDU / TMV
Upon application of input voltage, the time delay begins. At the end of
the time delay, the output energizes and remains energized until input
DIN rail P/Ns:
voltage is removed.
017322005 (Steel)
V = Voltage R = Reset TD = Time Delay
← Technical Data - TDU / TMV L = Load
Output
→ Type Solid state Connection - TDU / TMV
DIN rail adaptor
P/N: P1023-20 Form Normally Open, open during timing
Life Span 100 million operations typical
See accessory pages Maximum Load Current 1 A steady state, 10 A inrush at 60°C
Minimum Holding Current 40 mA
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Package 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm)
Protection Encapsulated Circuitry
Termination 0.25 in. (6.35 mm) male quick connect terminals
Dashed lines are internal connections.
Load may be connected to terminal 3 or 1.

TMV Series - Knob Adjustable, Universal Voltage Timers


The TMV series is a knob adjustable, universal voltage delay on make timer.
Encapsulation protects against humidity, vibration, and dust making it suitable for
outdoor equipment installations. Because of the large number of applications, it is
our most popular 1 amp solid state timing module. Designed to connect in series
with a relay coil, contactor coil, solenoid, lamps, small motor, etc., to delay their
energization, prevent short cycling or to sequence on various loads.
Operates From 24 ...
240 V AC/DC Universal timing module - One part number can be used for all the popular
Knob or External Adjust voltages and time delays.
01.08.08

Time Delays
Delays from 0.1 ... 8 m
Totally Solid State - Ordering Table
Encapsulated
1 A Steady - 10 A Inrush
TDU5pp

Part Number Input Voltage Time Range (minutes) Adjustment Repeat Accuracy Tolerance
Two Terminal Series TMV8000 24 ... 240 V AC/DC 0.1 ... 8 M Knob +/- 2% ≤ +/- 10%
Connection with Load

22 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
d
r an mer Flashing and Recycling Modules
e i
l a sh ng T FS100 / RS Series
F c l i
cy 1A Solid State Modules
Re

FS100 Series - Fixed Flash Rate - Low Cost Function


The FS100 Series may be used to control inductive, incandescent or
resistive loads. This series offers a 1 A (fullwave) or a 2 A (halfwave) steady
state, 10 A inrush solid state output. These totally solid state flashers are
encapsulated to protect against, humidity, vibration and dust and they
typically deliver 100 million flashes. Ideal for OEM applications where low
cost and long life are important.
V = Voltage R = Reset L = Load
Technical Data T1 = ON Time T2 = OFF Time

Mechanical
Connection
Mounting Removable mounting bracket, use one #8 (M4 x 0.7) screw
Connection/Wires 18 AWG (0.82mm2) wires 6 in. (15.2cm)
Package 1.5 x 0.94 in. (38.1 x 23.9 mm)
Fixed Flash Rate at 75
Flashes Per Minute
1 or 2 A Output
24 or 120 V AC are Available
Small Size: 1.5 x 0.94 in.
(38 x 23.9 mm) Ordering Table
Part Number Input Output Rating Steady / Inrush Output Type Load Type *
FS126 A
1 A / 10 A AC, Fullwave V = Voltage L = Load
FS126RC 120 V AC B R = Red Wire B = Black Wire
FS127 2 A / 10 A AC, Halfwave
A
FS146 24 V AC 1 A / 10 A AC, Fullwave
* Load Type: A - Incandescent & Resistive B - Incandescent, Resistive & Inductive

RS Series - Solid State Recycling Timer - Switch Adjustable


See the inside front cover for details
The RS Series is a solid state,
encapsulated, recycling timer Function
designed for tough industrial
environments. It is used by many Recycling ON Time First
testing labs as a life cycle tester;
by others as a cycle controller.
The RS Series has separate
DIP switch adjustments for the
ON delay and the OFF delay. V = Voltage L = Load R = Reset
These make possible accurate T1 = ON Time T2 = OFF Time
adjustment the first time and
every time.

Add the value of


Connection
switches in the ON
Accurate, Reliable, Life Cycle position for the total
Timer; 100 Million Cycles Typical time delay.
Switch Settable Time Delays -
Both Times Adjustable Technical Data
+/-0.1% Repeat Accuracy
+/-2% Setting Accuracy Output
0.1 s ... 1023 h in 4 Ranges Maximum Load Current 1 A steady state, 10 A inrush at 60°C
FS-RSpp

12 ... 230 V in 5 ranges Mechanical


1 A Solid State Output
Mounting Surface mount with one #10 (M5 x 0.8) screw
Totally Solid State and
Encapsulated Package 3 x 2 x 1.5 in (76.7 x 51.3 x 38.1 mm)
06.11.08

Termination 0.25 in. (6.35 mm) male quick connect terminals


Dashed lines are internal connections.
Mounting Accessory Ordering Table
RS X X X X
Series Input Operating Sequence T1 ON Time T2 OFF Time
DIN rail P/Ns:
–1 - 12 V DC –A - ON Time First –1 - 0.1 ... 102.3 s in –1 - 0.1 ... 102.3 s in
017322005 (Steel)
–2 - 24 V AC –B - OFF Time First 0.1 s increments 0.1 s increments
–3 - 24 V DC –2 - 0.1 ... 102.3 m in –2 - 0.1 ... 102.3 m in
← –4 - 120 V AC 0.1 m increments 0.1 m increments
–6 - 230 V AC –3 - 1 ... 1023 m in –3 - 1 ... 1023 m in
→ †
Note: Grayed options are available in standard lead time. 1 m increments 1 m increments
DIN rail adaptor –4 - 1 ... 1023 h in –4 - 1 ... 1023 h in
P/N: P1023-20 1 h increments 1 h increments
Example P/N:
See accessory pages RS4A23 = 120V AC operation, ON time first, T1 - ON time range 2, T2 - OFF time range 3
RS6B14 = 239V AC operation, OFF time first, T1 - ON time range 1, T2 - OFF time range 4

Low Voltage Products & Systems 23


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
r
se to Universal 3 Phase Voltage Monitor
P ha oni
3 eM HLMU Series (DPDT)
g
lta
Vo Universal Voltage Motor Protector
New: LED Indicates Phase Reversal
Anti-Short Cycle & Staggered Restarting LED status indicator blinks red/green on phase reversal.
0.6 to 300 s prevents rapid cycling. Allows staggered
restarting of multiple systems on a common power Green indicates restart
distribution network. delay or output relay
energized
Universal Voltage Operation Red indicates trip
3 ranges. Adjust to the motor’s operating delay or output
voltage and the unit automatically sets the denergized due to a
over and under voltage trip points. voltage fault
Improved Phase Loss Protection
Unaffected by regenerated voltages, knob
adjustable, 2 to 10%, unbalance protection.

ANSI Device #27/47/59 Prevents Nuisance Tripping


Adjustable trip delay from 1 to 30 Sec.

Protects Against: Phase Trip Delay Red 120 FPM


ON/OFF
Loss, Phase Reversal, Restart Delay Green 60 FPM
Over, Under & Unbalanced
Operation Phase Reversal Red/Green Alternate 120 FPM
Voltages, Over/Under
Upon application of line voltage, the output is de-energized FPM = Flashes per minute
Frequency
and the restart delay begins. If all the three phase voltages
Encapsulated Circuitry
are within the acceptable range, the output energizes at
DPDT Isolated 10 A Contacts
the end of the restart delay. The microcontroller circuitry
Connection
LED Indicates Relay Status,
automatically senses the voltage range, and selects the correct
Faults, & Time Delays
operating frequency (50 or 60hz). The over and under voltage
Universal Line Voltage
trip points are set at approximately +/- 10% of the adjusted
200 ... 480 V AC in One Unit
line voltage. When the measured value of any phase voltage
Compact, Encapsulated Design
exceeds the acceptable range limits (lower or upper) the trip
Finger-Safe Terminal
delay begins. At the end of the trip delay the output relay
Blocks, up to 12 AWG
de-energizes. Under, over, and unbalanced voltages plus
ASME A17.1 rule 210.6
over or under frequency must be sensed for the complete
NEMA MG1 14:30, 14:35
trip delay before the unit trips. The unit trips in 200 ms when
IEEE C62.41-1991 Level B
phase loss or reversal are sensed. The unit will not energize if
a fault is sensed as the line voltage is applied. Both Delta and CAUTION: 2 amp max. fast
Wye systems can be monitored; no connection to neutral is acting fuses are recommended
required. to protect the equipment‘s
Reset: Reset is automatic upon correction of the voltage or wiring. They are not required to
frequency fault or phase sequence. protect the HLMU.

L1, L2, L3 = Line Voltage Input


R= Restart Delay on fault correction. The restart delay
NO = Normally Open Contact NC = Normally Closed Contact
begins when line voltage is reapplied or when a voltage fault
C = Common, Transfer Contact
is corrected. This option is normally selected when staggered
restarting of multiple motors on a power system is required. Note: Relay contacts are isolated, 277 V AC max.

Technical Data
Sensing/Protection
Mounting and Connection
Accessories Phase Loss ≥ 25% Unbalance
Response Time ≤200ms
Over/Under Frequency Protection Trip ±4%; Reset ±3%; 50 or 60 Hz
DIN rail P/Ns:
017322005 (Steel)
Output
10 A resistive at 240 V AC; 8 A resistive at 277 V AC;
Rating
N.O-1/4 hp at 120 V AC; 1/3 hp at 240 V AC;
Mechanical
Mounting Surface mount with one #10 (M5 x 0.7) screw
DIN rail adaptor
P/N: P1023-20 Package 3 x 2 x 1.5 in. (76.7 x 51.3 x 41.7 mm)
Termination Screw terminal connection for up to 12 AWG (3.3 mm2) wire
Degree of Protection Terminals IP20

3-Pole Fuse Block


Mounts on 35mm
01.17.08

DIN Rail Ordering Table


P/N: FH3P
2 Amp Midget Fuse Part Number Line Voltage Output Form Adj. Unbalance Adj. Trip Delay Adj. Restart
P/N: P0600-11 HLMUDRAAA 200 to 480 V AC DPDT 2 to 10% 1 to 30 S 0.6 to 300 S
HLMU1pp

See accessory pages

24 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
r
h
e
as nito Universal 3 Phase Voltage Monitor
o
3P eM DLMU Series (SPDT & N.O.)
g
lta Universal Voltage Motor Protector
Vo Available 2nd Quarter 2008

Improved Phase Loss Protection


Adjustable, 2 to 10%, unbalance protection.
Anti-Short Cycle & Staggered Restarting
0.6 to 300 s prevents rapid cycling. Allows staggered restarting
of multiple systems on a common power distribution network.
LED Indicates Phase Reversal
LED status indicator blinks red/green on phase reversal.
Prevents Nuisance Tripping
Adjustable trip delay from 1 to 30 Sec.
Universal Voltage Operation
In 3 ranges. Adjust to the motor’s operating voltage and the
unit automatically sets the over and under voltage trip points.
ANSI Device #27/47/59

Operation
Protects Against: Phase
Loss, Phase Reversal, Over, Upon application of line voltage, the output is de-energized and the restart delay begins. If all the three phase voltages are
Under and Unbalanced Voltages, within the acceptable range, the output energizes at the end of the restart delay. The microcontroller circuitry automatically
Over/Under Frequency senses the voltage range, and selects the correct operating frequency (50 or 60hz). The over and under voltage trip points
35 mm DIN Rail or Surface are set at approximately +/- 10% of the adjusted line voltage. When the measured value of any phase voltage exceeds the
Mounting acceptable range limits (lower or upper) the trip delay begins. At the end of the trip delay the output relay de-energizes.
SPDT Isolated 10 A Relay Under, over, and unbalanced voltages plus over or under frequency must be sensed for the complete trip delay before the
Contacts unit trips. The unit trips in 200 ms when phase loss or reversal are sensed. The unit will not energize if a fault is sensed as
N.O. Isolated 2A Relay Contact the line voltage is applied. Both Delta and Wye systems can be monitored; no connection to neutral is required.
LED Indicates, Relay, Faults, Reset: Reset is automatic upon correction of the voltage or frequency fault or phase sequence.
& Time Delays
Universal Line Voltage Connection
240 ... 480 V AC in One Unit
Finger-safe Terminal Blocks,
CAUTION: 2 amp R= Restart Delay on fault correction
max. fast acting fuses The restart delay begins when line voltage is
up to 12 AWG
are recommended reapplied or when a voltage fault is corrected.
ASME A17.1 rule 210.6
to protect the This option is normally selected when
NEMA MG1 14:30, 14:35
equipment‘s wiring. staggered restarting of multiple motors on a
IEEE C62.41-1991 Level B
They are not required power system is required.
to protect the DLMU.
Dashed lines are
internal connections.

L1, L2, L3 = Line Voltage Input


NO = Normally Open Contact NC = Normally Closed Contact
C = Common, Transfer Contact
Note: Relay contacts are isolated, 277 V AC max.

Technical Data
Phase Loss
Response Time ≤200ms
Trip Point >=25% Unbalance
Over/Under Frequency Trip / Reset Trip +/- 4%; Reset +/- 3%; 50 or 60 Hz
Output
10 A resistive at 240 V AC; 8 A resistive at 277 V AC;
DLMUpp

SPDT (c/o) Rating


N.O-1/4 hp at 120 V AC; 1/3 hp at 240 V AC
N. O. SPST Rating 2 A resistive at 240 V AC
Mechanical
Accessories Mounting Surface mount with 2 #8 (M4 x 0.7) screw or snap on 35mm DIN Rail
06.11.08

Package 4.33 x 2.95 x 1.97 in. (110 x 75 x 50 mm)


Termination Screw terminals with captive wire clamps for up to #14 AWG (2.5 mm2) wire
3-Pole Fuse Block Degree of Protection Terminals IP20 with protective covers installed
P/N: FH3P
35mm DIN Rail LED Flashing Table
Mounting
Trip Delay Red 120 FPM*
ON/OFF
Restart Delay Green 60 FPM*
Phase Reversal Red/Green Alternate 120 FPM*
2 Amp Midget Fuse *FPM = Flashes per minute
P/N: P0600-11
Ordering Table
See accessory pages Part Number Line Voltage Output Form Adj. Unbalance Adj.Trip Delay Adj. Restart
DLMUBRAAA 200 to 480 V AC SPDT & NO 2 to 10% 1 to 30 S 0.6 to 300 S

Low Voltage Products & Systems 25


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
se r
ha nito
3 Phase Voltage Monitor
P
3 Mo
e
PLMU Series (SPDT)
Lin Universal Voltage Plug-in Monitor

Connection
Universal Operating Voltage 2 amp fast acting
200 - 480 V AC; 50 & 60 Hz fuses recommended
to protect the
Improved Phase Loss Protection equipment. They
Unbalance sensitivity assures improved are not required to
phase loss protection not affected by protect the PLMU.
regenerated voltages; knob adjustable
2 to 10% unbalance protection.

Prevents Nuisance Tripping


Adjustable 0.25 to 30 s trip delay
prevents nuisance tripping.
ANSI Device #27/47/59
Bicolor LED indicates relay status,
Replaces delays, faults, and phase reversal. F = Fuses
Hundreds of ØA = Phase A = L1
Standard ØB = Phase B = L2
Protects Against: Phase Loss, Part Numbers
Improves ØC = Phase C = L3
Phase Reversal, Overvoltage, Performance NO = Normally Open
Undervoltage, & Unbalanced NC = Normally Closed
Voltages C = Common, Transfer Contact
Octal Plug-in with SPDT Universal voltage operation and standard base connection allows the
Isolated 10 A Contacts PLMU to replace hundreds of competitive part numbers. Relay contacts are isolated; 277V AC max.
Operates from 200 ... 480 V AC
The PLMU Series continuously measures the voltage of each of the three Dashed lines are internal connections.
LED Indicator Glows Green
phases to provide protection for three phase motors and sensitive loads.
when Voltages are
Its microcontroller senses under and over voltage, voltage unbalance,
Acceptable, Red for Faults
phase loss, and phase reversal. Protection is provided even when
Simple 3-Wire Connection for
regenerated voltages are present.
Delta or Wye Systems
ASME A17.1 rule 210.6 Operation
NEMA MG1 14:30, 14:35
Upon application of power, a 0.6 s random start delay begins and the
IEEE C62.41-1991 Level B
PLMU measures the voltage levels and line frequency and selects
the voltage range. The voltage range is automatically selected by
the electronic circuitry during the 0.6 s start delay. The output relay
energizes (pin 1 & 8 close) and the LED glows green when all voltages are
acceptable and the phase sequence is correct. The LED flashes green
during trip delay, glows red when output de-energizes. Undervoltage,
overvoltage, and voltage unbalance must be sensed for continuous trip
delay before the relay de-energizes. Re-energization is automatic after
fault correction. The output relay will not energize if a fault condition is
sensed as three phase input voltage is applied.

Technical Data
Mounting and Connection
Line Voltage
Accessory
Line Voltage 200 ... 480 V AC +/-15%; 50 ... 60 Hz +/-2 Hz
Output
35 mm DIN or Rating 10 A resistive @ 240 V AC; 1/4 hp @ 125 V AC; 1/3 hp @ 250 V AC; max. voltage 277 V AC

06.11.08
Surface Mounting Mechanical
Mounting & Connection Requires an accessory plug-in socket rated 600 V AC
Octal 8 pin socket Package 3.03 x 2.39 x 1.78 in. (77.0 x 60.7 x 45.2 mm)
P/N: OT08PC
PLMUpp

Must be rated for Ordering Table


600 V operation
Part Number Voltage Unbalance Trip Delay
PLMU11 Adjustable 2 ... 10% Adjustable 0.25 ... 30 s

See accessory pages

26 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
se r
ha nito
3 Phase Voltage Monitor
P
3 Mo
e
WVM Series 10A SPDT
Lin Motor Protector with 10 Fault Memory

6 LED Status Panel


Displays current line status and faults in memory.
Improved Phase Loss Protection
Unaffected by regenerated voltages, plus adjustable, 2 to
10%, unbalance protection.
Adjust to the Motor’s Operating Voltage
The unit automatically sets the over and under voltage trip
points.
Prevents Nuisance Tripping
Adjustable Trip Delay 0.25 to 30 Seconds
Switch Selectable Reset Method
Automatic with or without Restart Delay, or Manual Reset

ANSI Device #27/47/59 A True Random Restart Delay


3 to 15 s delays the restart of protected motors until after
momentary brownouts caused by lighting and heating
Protects Against: Phase loads have passed and the voltage stabilizes.
Loss & Reversal; Over,
Under & Unbalanced Anti-Short Cycling & Staggered Restarting
Voltages; Short Cycling Adjustable Restart Delay 0.25 s to 64 m prevents rapid
10 Fault Memory & Status The WVM Series provides protection against premature cycling. Allows staggered restarting of multiple systems
Displayed on 6 LED Readout equipment (motor) failure caused by voltage faults on the on a common power distribution system.
Switch Selectable Automatic 3 Phase Line. The WVM’s microcontroller design provides
Restart, Delayed Automatic reliable protection even if regenerated voltages are present.
Restart, & Manual Reset It combines dependable fault sensing with a 10 fault memory
and a 6 LED status display. Part instrument, part control, Connection
Isolated 10 A SPDT Relay
the WVM protects your equipment when you’re not there
Contacts and displays what happened when you return. The WVM is
Part Instrument Part Control fully adjustable and includes time delays to prevent nuisance
Pays For Itself During One tripping and improve system operation. Time delays include
Single Phasing Event a 0.25 to 30 s adjustable trip delay, an adjustable 0.25 to
Universal Voltage Sensing 64 m (in 3 ranges) restart delay, plus a unique 3 to 15 s true
Design Protects any Size Motor. random start delay. The random start delay prevents voltage CAUTION:
From Fractional to 1200 Hp. sags caused by simultaneous restarting of numerous motor 2 amp max fast acting fuses
loads after a power outage. must be installed externally
in series with each input. (3)
Relay contacts are isolated.
Dashed lines are internal
connections.

F = Fuses
NO = Normally Open
NC = Normally Closed
RS = Optional Remote
Reset Switch

Technical Data
Phase Loss ≥ 15% unbalance
Accessories Response Time ≤ 200 ms
True Random Start Delay 3 ... 15 s
Fault Memory
3-Pole Fuse Block
35 mm DIN Rail Capacity Stores last 10 faults
Mounting Status Indicators 6 LEDs provide existing status & memory readout
P/N: FH3P Output
Rating 10 A resistive @ 250 V AC; 6 A inductive (0.4 PF) at 250 V AC
2 Amp Midget Fuse Mechanical
P/N: P0600-11 Termination Screw terminals with captive wire clamps for up to #12 AWG ( 3.2 mm2) wire
Package Size 6.9 x 4.4 x 2.4 in (175.3 x 111.8 x 2.4 mm)

Ordering Table
WVMpp

Part Number Line Voltage Output Form Adj. Unbalance Adj. Trip Delay Adj. Restart
WVM911AH 0.25 to 64M
400 to 480 V AC SPDT 2 to 10% 0.25 to 30 S
WVM911AL 0.25 to 64S
See accessory pages
01.17.08

Low Voltage Products & Systems 27


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
se r
ha nito
Phase Sequence Monitors
P
3 Mo
e
CM-PFS Series
Lin Universal Voltage DPDT Relay Output

CM -PFS Universal Voltage Phase Reversal Monitor

The CM-PFS phase sequence monitor is used with motors which continue running on
used to monitor three-phase supply voltages only two phases, the CM-PFS detects phase
for incorrect phase sequence. The output loss if the regenerated voltage is less than
relay energizes and the yellow LED turns on 60% of the nominal voltage. For applications
if all phases are present in the correct phase where a regenerated voltage greater than 60%
sequence (clockwise rotating field). is expected, we recommend using our phase
The relay de-energizes and the yellow LED unbalance monitors.
turns off if incorrect phase sequence or
complete loss of one phase is detected. If

1 R: yellow LED - relay status

Monitoring of three-phase supply


voltage for phase sequence
Fast response time Function Connection
Universal voltage range
3 x 200…500 V 50/60 Hz L1-L2-L3 Measuring circuit
DPDT contacts L1, L2, L3 3 x 200…500 V AC
LED for status indication 50/60 Hz
11/14
11/12 1115-1216 /1418, Output contacts
2125-2226/2428
21/24
21/22

Technical Data
Output 11-12/14, 21-22/24 Relay, 2 SPDT (c/o) contacts
Rated switching voltage max. 250 V AC
AC 12 (resistive) 4 A (at 230 V)
Rated switching current
AC 15 (inductive)) 3 A (at 230 V)
General Data
Mounting to DIN rail 35 mm DIN Rail Mounting, no tools required

Ordering Table
Part Number Series Line Voltage
1SVR 430 824 R 9300 CM-PFS 200…500 V AC 50/60 Hz

01.17.08
PFSpp

28 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
se s
P ha itor Voltage Monitoring Relays
le on
i
S g
ng e M CM-ESS.1 and CM-ESS.2 Series
lta Single Phase AC/DC DIN Relay Mount
Vo

CM-ESS.1 and CM-ESS.2 are used for over or under voltage


monitoring in single-phase AC and/or DC systems. The voltage to be
monitored (measured value) is applied to terminals B-C. The output
relay is normally de-energized.
If the monitored RMS voltage exceeds/drops below the adjusted
1 Hysteresis Adjustment threshold value, the output relay(s) energize(s): on the CM-ESS.1
2 Adjustable Trip Point immediately. The CM-ESS.2 changes state after the set trip delay TV. If
3 U: Red LED - the monitored RMS voltage exceeds/drops below the threshold value
Over/Under Voltage plus/minus the adjusted hysteresis, the output relay(s) de-energize(s).
4 R: Yellow LED - Relay Status The hysteresis is adjustable within a range of 3 to 30 % of the
5 U/T: Green LED - threshold value.
Input Voltage, Timing
6 Adjustable Trip Delay TV Overvoltage monitoring
CM-ESS.1 (CM-ESS.2)
7 Sensing Range Selection
8 DIP Switches (see functions)
9 Compact Package

22.5mm

Undervoltage monitoring
DIP Switch Functions
2CDC 252 275 F0005

1 - ON OFF Delay
- OFF ON Delay

CM-ESS.2

3 ... 600 V AC or DC Voltage


Monitoring in 4 Ranges Connection Diagrams
RMS Measuring Note: CM-ESS.2 has second set of SPDT contacts.
CM-ESS.1 CM-ESS.2 See the on-line data sheet for a complete set of function diagrams.
Each Unit Includes 4
Measuring Ranges A1 1115 C
2CDC 252 206 F0005

A1 1115 2125
Selectable Over or Under B B
Voltage B 1115 B 1115 2125
Hysteresis Adjustable 3 ... 30%
CM-ESS.2: Adjustable Trip A1-A2 Input Voltage
C C
Delay TV 0.1-30 s Measuring Ranges
Universal 24 ... 240V AC/DC B-C
3-30 V; 6-60 V; 30-300 V; 60-600 V
Voltage A1 A2 1216 1418 A1 A2 12161418 2226 2428
1115 - 1216 / 1418
CM-ESS.1: SPDT (c/o) Contact 1418 1216 C Output Contacts
CM-ESS.2: 2 SPDT (2 c/o) 1418 1216 A2 2428 2226 A2 2125 - 2226 / 2428
Contacts
22.5 mm Width
3 LEDs for Status Indication Technical Data
Measuring Circuit
Repeat Accuracy (constant parameters) +/- 0.07% of Full Scale
Output
ESSpp

AC12 (resistive) at 230 V 4A


AC15 (inductive) at 230 V 3A
Mechanical
06.11.08

Dimensions W x H x D .89 x 3.93 x 3.07 in. (22.5 x 100 x 78 mm)


Mounting 35 mm DIN Rail, no tools required
Degree of Protection Enclosure IP50 / Terminals IP20

Ordering Table
Series Part Number Input Voltage - 50/60 Hz Trip Delay TV Sensing Range Output Form
1SVR 430 830 R0300 24-240 V AC/DC
CM-ESS.1 Without SPDT (c/o)
1SVR 430 831 R0300 110-130 V AC 3-30 V; 6-60 V
1SVR 430 830 R0400 24-240 V AC/DC Adjustable 30-300 V; 60 600 V
CM-ESS.2 2 SPDT (2 c/o)
1SVR 430 831 R0400 110-130 V AC 0 or 0.1 - 30 s

Low Voltage Products & Systems 29


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
se s
P ha itor Voltage Window Monitoring Relays
le on
i
S g
ng e M CM-EFS.2 Series
lta Single Phase AC/DC, DIN Rail Mounting
Vo

The voltage window monitoring relay CM-EFS.2 can be used for the
simultaneous monitoring of over (>U) and under (<U) voltages in single-
phase AC and/or DC systems. A true RMS sensing method is used. The
2 SPDT (2 c/o) output relays can be set to transfer together or operate
as separate outputs for over and under voltage. The voltage to be
1 Trip Point Adjustment monitored (measured value) is applied to terminals B-C. Normally de-
>U - undervoltage energized or normally energized operation as well as an adjustable ON
2 Trip Point Adjustment or OFF trip delays can be selectable.
>U - Overvoltage
When the latching function is selected, after the output trips, it remains
3 U: Red LED - Over / Under
transferred until the input voltage is removed. See on-line data sheet for
Voltage
further details.
4 R: Yellow LED - Relay Status
5 U/T: Green LED -
Input Voltage,Timing Function
6 Adjustable Trip Delay TV
7 Selectable Measuring Range
8 DIP Switches (see functions)

3...600 V DC/AC Voltage


Monitoring in 4 Ranges
RMS Measuring Position 4 3 2 1
Each Unit Includes 4
closed
Measuring Ranges: 3-30 V; ON 2x1 c/o
6-60 V; 30-300 V; 60-600 V
Over and Under Voltage
OFF 1x2 c/o
Monitoring open

ON or OFF Delay Selectable


DIP Switch Functions
Selectable Normally Open or
Normally Closed Output 1 - ON = OFF Delay
Selectable Latching Function - OFF = ON Delay
Adjustable Trip Points for Vmin 2 - ON Normally Energized
and Vmax OFF Normally De-energized
Fixed Hysteresis of 5%
3 - ON Latching Function Activated
Adjustable Trip Delay
OFF Latching Function Not Activated
TV 0.1-30 s
Select 2 SPDT (c/o) to Transfer 4 - ON DPDT (2 c/o) Both Relays Transfer
Together or Separate Outputs at the Same Time
for Over and Under Voltage OFF 1 SPDT (c/o) Transfers on Overvoltage,
22.5 mm Width 1 SPDT (c/o) Transfer on Undervoltage
3 LEDs for Status Indication

Connection
See Data Sheet for A Complete Set of Function Diagrams
A1 1115 2125
B
B 1115 2125

A1-A2 Input Voltage


C
Measuring Range:
B-C
3-30 V; 6-60 V; 30-300 V; 60-600 V
A1 A2 12161418 2226 2428
1115 - 1216 / 1418
1418 1216 C Output Contacts
2428 2226 A2 2116 - 2226 / 2428

Technical Data
Measuring Circuit
Repeat Accuracy (constant parameters) +/- 0.07% of Full Scale
Output
AC12 (resistive) at 230 V 4A
AC15 (inductive) at 230 V 3A
Mechanical
Dimensions W x H x D .89 x 3.93 x 3.07 in. (22.5 x 100 x 78 mm)
Mounting 35 mm DIN Rail, No Tools Required
Degree of Protection Enclosure IP50 / Terminals IP20

Ordering Table
01.14.08

Series Part Number Input Voltage - 50/60 Hz Adjustable Trip Delay TV Sensing Range Output Form
AC/DC: 3-30 V; 6-60 V
CM-EFS.2 1SVR 430 750 R0400 24-240 V AC/DC 0 or 0.1-30 s SPDT (c/o)
30-300 V; 60 600 V
EFSpp

30 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
nt AC Current Sensing - Indication
u rre rs &
C so rs
n to ECS / LCS / LPM Series
Se oni
M Current Sensor - Current Indicator

The ECS Series of Single Phase AC Current Sensors is a universal, overcurrent or undercurrent sensing control. Its built-in
toroidal sensor eliminates the inconvenience of installing a stand-alone current transformer. Includes onboard adjustments for
current sensing mode, trip point, and trip delay. Detects over or under current events like locked rotor, loss of load, an open
heater or lamp load, or proves an operation is taking place or has ended.

Connection Function
Overcurrent

Undercurrent

Toroidal Through Hole Wiring


0.5...20 A Adjustable Trip Point
Adjustable Trip Delay
10 A SPDT Isolated Output
Contacts Relay contacts are isolated. TP = Trip Point R = Reset OC = Monitored Current
5% Trip Point Hysteresis Dashed lines are internal connections. NO = Normally Open Contact NC = Normally
(Dead Band) V = Voltage I> = Overcurrent I< = Undercurrent Closed Contact A = Sensing Delay On Start Up
W = Insulated Wire Carrying Monitored Current TD = Trip Delay

Technical Data
Sensor
Maximum Allowable Current Steady – 50 A turns; Inrush – 300 A turns for 10 s
Output
Rating 10 A resistive at 240 V AC; 1/4 hp at 125 V AC; 1/2 hp at 250 V AC
Mechanical
Mounting Surface mount with two #6 (M3.5 x 0.6) screws
Termination 0.25 in. (6.35 mm) male quick connect terminals (5)

Ordering Table
Part Number Input Voltage Adjustable Set Point Adjustable Trip Delay Delay on Start
ECS40BC 0.5…5 A AC
120 V AC 0.5…50 sec Fixed 1 sec
ECS41BC 2...20 A AC

LCS and LPM Current Flow Indication Connection


The LCS10T12 connected to the LPM12 or LPMG12 indicator is a Wire Length:
low cost, easy to use, go/no go indication system for the remote 500 Ft. (152.4 m) Max.
monitoring of current flow. The LCS10T12 is installed on an (Customer Supplied)
adequately insulated wire of the monitored load. Its 12 in. (30.4
cm) leads are connected to the LPM12 or LPMG12 panel mount
indicator. When current flows through the monitored wire the LED
indicator glows.
ECS-LCSpp

Technical Data
Monitored Current
02.20.09

Current Range 2 ... 50 A AC


Wire Passes Min. Current Max. Current Max. Inrush Max. Wire Dia.
1 5A 50 A 120 A 0.355 in. (9.0 mm)
2 2.5 A 25 A 60 A 0.187 in. (4.7 mm)
Low Cost Go/No Go
3 1.7 A 16.6 A 40 A 0.15 in. (3.8 mm)
Indication
Maximum Current 50 ampere-turns continuous
May Be Connected To Wires
Up To 500 Feet (152.4 m) Mechanical
Long Sensor Hole 0.36 in. (9.14 mm) for up to #4 AWG
Remote Monitoring of (21.1 mm2) THHN wire
Currents Up To 50 A
Green or Red LED Indicator Ordering Table
Available Part Number Description
LCS10T12 AC Current Sensor
LPM12 Red LED Indicator
LPMG12 Green LED Indicato

Low Voltage Products & Systems 31


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
nt AC Current Sensor, PLC Interface Module
u rre rs &
C so rs
n to TCS / TSCA Series
Se oni
M AC Current Sensor / Current Transducer

TCS Series, Current Sensor Connection


The TCS Series is a low cost method of GO/NO GO current detection. It
includes a solid state output to sink or source current when connected Positive
directly to a standard PLC digital input module. Switching
Normally Open: When a current equal to or greater than the actuate Shown.
current is passed through the toroidal sensor, the output closes. When Compatible
the current is reduced to 95% the output opens. with Negative
Normally Closed: When the current through the toroid is equal to or Switching;
greater than the actuate current, the output opens. When the current is Sinking and
reduced below 95% the output closes. Sourcing.

Technical Data
Sensor
Direct Connection to a PLC Current to Actuate 2 ... 20 A, Guaranteed Range
Digital Input Module Reset Current 95% of the actuate current
3 ... 50 V DC, 24 ... 240 V AC
in 2 Ranges Mechanical Monitored AC
1 A Steady - 10 A Inrush Package 2 x 2 x 1.75 in. (50.8 x 50.8 x 44.5 mm) conductor must
Adjustable Set Points – 2 ... 20 A Termination 0.25 in. (6.35 mm) male quick connect terminals (2) be insulated.
Normally Open or Closed
Sensor Hole 0.36 in. (9.14 mm) for up to #4 AWG (21.1 mm2) THHN wire
Function
Solid State Output
Complete Isolation Between GO/NO GO Sensing
Sensed Current & Control Circuit
Ordering Table
Part Number Output Volts Adjustable Set Point Output Form
TCSGAA 3…50 VDC Normally Open
TCSGAB 3…50 VDC Normally Closed
2...20 A AC L = Load V = Voltage PS = Power Supply
TCSHAA 24…240 VAC Normally Open PLC = PLC Digital Input Module R = Reset
TCSHAB 24…240 VAC Normally Closed TP = Trip Point OC = Monitored Current
NO = Normally Open Output
NC = Normally Closed Output

TCSA Series, AC Current Transducer


The TCSA Series is a loop powered, linear output current transducer that provides an output that is
directly proportional to the RMS AC current passing through the onboard toroid. The TCSA provides
a 4 to 20 mA output. The 0 to 5 A range allows the use of external current transformers so loads up to
1200 AC amps can be monitored.
Connection
Span and Zero adjustments PS
are provided for minor
calibration adjustments in
the field (if required).

Monitors 0 ...50 A in 4 Ranges


Loop Powered from
10 ... 30 V DC
Linear Output from 4 ... 20 mA Technical Data
Zero and Span Adjustments Sensor
Complete Isolation Between PS = Power Supply Z = Zero Adjust
Sensed Current and Control Factory Calibration +/-0.5% of full scale S = Span Adjust W = Insulated Wire
Circuit Repeat Accuracy +/-0.25% of full scale under fixed conditions Carrying Monitored Current
PLC = PLC Analog Input or Meter Input
Mechanical
Package 2 x 2 x 1.75 in. (50.8 x 50.8 x 44.5 mm)
Termination 0.25 in. (6.35 mm) male quick connect terminals

Ordering Table
01.07.08

Part Number Current Range Loop Voltage Range


TCSA5 0 ... 5 A
See accessory pages TCSA10 0 ... 10 A
TCS1pp

10 ... 30 V DC
TCSA20 0 ... 20 A
TCSA50 0 ... 50 A

32 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
nt Current Monitoring Relays
r re rs
Cu nito CM-SRS.1 and CM-SRS.2 Series
o
M Single-phase AC/DC DIN Rail Mounting

CM-SRS.1 and CM-SRS.2 current monitoring relays can be used for


overcurrent or undercurrent monitoring in single-phase AC and/or
DC systems. These devices feature monitoring of true RMS values.
The current to be monitored (measured value) is applied to terminals
B1/B2/B3-C.
If the measured value exceeds or drops below the selected trip point
value, the output relay(s) energize: on the CM-SRS.1 immediately, on
1 Hysteresis Adjustment
the CM-SRS.2 after the trip delay TV. The relay de-energizes when
2 Trip Point Adjustment
the current returns to an acceptable level. The adjustable hysteresis
3 Adjustment of the Tripping
prevents rapid cycling.
Delay TV
4 I: Red LED - Over/Under Current The hysteresis is adjustable 3 to 30% of the threshold value.
5 R: Yellow LED - Relay Status
6 U/T: Green LED Input Overcurrent monitoring
Voltage, Timing
CM-SRS.1 7 DIP Switches (see DIP switch
functions)
8 Compact Package

22.5mm

DIP Switch Functions


Undercurrent monitoring
1 - ON Undercurrent Monitoring
- OFF Overcurrent Monitoring

CM-SRS.2

Monitoring of DC and Connection Diagrams Note: CM-SRS.2x has second set of SPDT contacts. See
AC Currents
CM-SRS.1 CM-SRS.2 on-line data sheet for the complete function diagrams
RMS Measuring
Each Unit Includes 3 Measuring A1 1115 C A1 1115 2125 A1-A2 Input Voltage
Ranges B1 B2 B3 B1 B2 B3 B1-C Measuring Range 1: 3-30 mA or 0.3-1.5 A
Selectable Over or Under B1 B2 B3 1115 B1 B2 B3 1115 2125 B2-C Measuring Range 2: 10-100 mA or 1-5 A
Current Monitoring
Adjustable Hysteresis 3 ... 30% B3-C Measuring Range 3: 0.1-1 A or 3-15 A
C C
CM-SRS.2: Adjustable Trip Delay 1115 - 1216 / 1418
Output Contacts
0.1 ... 30s 2125 - 2226 / 2428
Universal 24 ... 240V AC/DC A1 A2 12161418 A1 A2 12161418 2226 2428
Voltage 1418 1216 C
CM-SRS.1: SPDT (c/o) Contacts 1418 1216 A2 2428 2226 A2
CM-SRS.2: 2 SPDT
(2 c/o) Contacts
22.5 mm Width
3 LEDs for Status Indication Technical Data
Measuring Circuit B1 / B2 / B3 - C
Repeat Accuracy (constant parameters) +/- 0.07% of Full Scale
Output
AC12 (resistive) at 230 V 4A
AC15 (inductive) at 230 V 3A
Mechanical
Dimensions W x H x D .89 x 3.93 x 3.07 in. (22.5 x 100 x 78 mm)
Mounting 35 mm DIN Rail Mounting, No Tools Required
Degree of Protection Enclosure IP50 / Terminals IP20

Ordering Table
Series Part Number Input Voltage - 50/60 Hz Trip Delay TV Sensing Range Output Form
1SVR 430 840 R0200 24-240 V AC/DC 3-30 mA;
CM-SRS.11 Without SPDT (c/o)
1SVR 430 841 R0200 110-130 V AC 10-100 mA; 0.1-1A
SRSpp

1SVR 430 840 R0300 24-240 V AC/DC 0.3-1.5 A;


CM-SRS.12 Without SPDT (c/o)
1SVR 430 841 R0300 110-130 V AC 1-5 A; 3-15 A
1SVR 430 840 R0400 24-240 V AC/DC Adjustable 3-30 mA;
CM-SRS.21 2 SPDT (2 c/o)
01.14.08

1SVR 430 841 R0400 110-130 V AC 0 or 0.1-30 s 10-100 mA; 0.1-1A


1SVR 430 840 R0500 24-240 V AC/DC Adjustable 0.3-1.5 A;
CM-SRS.22 2 SPDT (2 c/o)
1SVR 430 841 R0500 110-130 V AC 0 or 0.1-30 s 1-5 A; 3-15 A

Low Voltage Products & Systems 33


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
nt Current Window Monitoring Relay
u rre ors
C nit
o
CM-SFS.2 Series
M
Single-Phase AC/DC DIN Rail Mounting

The current window monitoring relays CM-SFS.2 can be used for the
simultaneous monitoring of over and under current in single-phase AC and/or DC
1 Trip Point Adjustment systems. A true RMS sensing method is used. The 2 SPDT (2 c/o) output relays
for Overcurrent can be set to transfer together or operate as separate outputs for over and under
2 Threshold Value Adjustment current. The current to be monitored is connected to terminals B1/B2/B3-C.
for Undercurrent Normally de-energized or normally energized output as well as an adjustable ON
3 I: Red LED - or OFF trip delays and a latching output after a fault trip, are selectable.
Over/Under Current When the latching function is selected, the output relays remain latched until the
4 R: Yellow LED - Relay Status input voltage is removed. (see On-Line Data Sheet for details)
5 U/T: Green LED -
Input Voltage, Timing Function
6 Trip Delay Adjustment
7 Start-up Delay Adjustment
8 DIP switches (see Functions)
9 Compact Package

22.5mm

3 mA ... 15 A Current
Monitoring in 6 Ranges Normally De-energized
Monitoring of DC and AC
Currents
RMS Measuring
Each Device Includes 3
Measuring Ranges
Connection
Over and Under Current A1 1115 2125
Monitoring B1 B2 B3
ON or OFF Delay Selectable
B1 B2 B3 1115 2125
Selectable Normally Open or Normally Energized
Normally Closed Output
Latching Function Selectable C
Adjustable Trip Points
for Imin and Imax A1 A2 12161418 2226 2428
Adjustable Hysteresis of 5 % 1418 1216 C
Start-up delay TS 2428 2226 A2
Adjustable 0; 0.1-30 s
Adjustable Trip Delay 0.1-30 s
Select 2 SPDT (c/o) Transfer
Together or Separate Outputs NOTE: See Data Sheet for A Complete Set of
for Over and Under Current Function Diagrams
A1-A2 Input Voltage
22.5 mm width
3 LEDs for status indication B1-C Measuring Range 1: 3-30 mA or 0.3-1.5 A
B2-C Measuring Range 2: 10-100 mA or 1-5 A
B3-C Measuring Range 3: 0.1-1 A or 3-15 A
1115 - 1216 / 1418
Output Contacts
2116 - 2226 / 2428

Position 4 3 2 1 DIP Switch Functions 3 - ON Latching Function Activated


1 - ON = OFF Delay (Function Shown) OFF Latching Function Not Activated
closed
ON 2x1 c/o
- OFF = ON Delay 4 - ON = DPDT (2 c/o) Both Relays
2 - ON Normally Energized Transfer at the Same Time
OFF 1x2 c/o
open OFF Normally De-energized OFF = 1 SPDT (c/o) Transfers
on Overvoltage,
1 SPDT (c/o) Transfer
Technical Data on Undervoltage
Measuring Circuit
Repeat Accuracy (constant parameters) +/- 0.07% of full scale
Output
AC12 (resistive) at 230 V 4A
AC15 (inductive) at 230 V 3A
Mechanical
Dimensions W x H x D Inches (mm) .89 x 3.93 x 3.07 in. (22.5 x 100 x 78 mm)
Mounting 35 mm DIN Rail, No Tools Required
Degree of Protection Enclosure IP50 / Terminals IP20

Ordering Table
01.16.08

Series Part Number Input Voltage - 50/60 Hz Trip Delay TV Sensing Range Output Form
3-30 mA;
CM-SFS.21 1SVR 430 760 R0400
Adjustable 10-100 mA; 0.1-1A
SFSpp

24-240 V AC/DC 2 SPDT (2 c/o)


0 or 0.1-30 s 0.3-1.5 A;
CM-SFS.22 1SVR 430 760 R0500
1-5 A; 3-15 A

34 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
l
ve Liquid Level Control - Alternating Relay
Le
& ols
u
p
m ntr LLC5 / ARP Series
P Co
Octal Plug-in – Relay Output

LLC5 Series Plug-in, Dual Probe, Liquid Level Control Connection


The LLC5 provides dual probe conductive liquid level control in a
convenient octal plug-in package. Transformer isolated AC voltage
on the probes prevents electrolytic plating. Less than 1 mA of
current is used to sense the presence of conductive liquid between
the probes and common. The sensitivity adjustment eliminates false
tripping caused by floating debris and foaming agents.

Operation
Drain (Pump Down Mode): When the liquid level rises and
touches the high level probe, the output relay energizes and
remains energized until the liquid level falls below the low level
probe. Connect common to conductive tank.
HP = High Level Probe LP = Low Level Probe
Fill (Pump Up Mode): When the liquid level falls below the low
C = Probe Common V = Voltage
level probe, the output relay energizes and remains energized
Dual Probe Level Control until the liquid level rises and touches the high level probe.
Dashed lines are internal connections.
for Conductive Liquids Accessory sensing probes are required.
Onboard Knob Adjust Technical Data
Sensing up to 100KΩ
Select Fill or Drain Operation Output
Rating 5 A resistive at 240 V AC; 1/10 hp at 240 V AC
LED Indicator Reduces
Mechanical
Adjustment Time Mounting and Connection 35mm or surface mounting, requires an accessory 8 pin (Octal) socket
5 A SPDT Isolated Contacts Package 3.2 x 2.39 x 1.78 in. (81.3 x 60.7 x 45.2 mm)

Ordering Table
Part Number Voltage Function Adjustable Range (ohms)
LLC54AA Drain
120 VAC 0...100 K
LLC54BA Fill

ARP Series Plug-in, Alternating and Duplexing Relay


The ARP Series is used in systems where equal run time for two motors is desirable. The selector switch
allows selection of alternation or either load for continuous operation. The LED’s indicate the status of
the internal relay and which load is selected to operate. This versatile series may be front panel mounted
(BZ1 accessory required) or 35 mm DIN rail mounted with an accessory socket.

Connection DPDT 8 Pin Cross Wired


Duplexing (Cross Wired): Duplexing models operate the
same as alternating relays and when both the Control (S1)
and Lag Load (S2) Switches are closed, Load A and Load
Provides Equal Run Time B energize simultaneously.
for Two Motors The DPDT 8-pin, cross wired option, allows extra system
Alternating or Electrically load capacity through simultaneous operation of both
Locked Operation motors when needed. Relay contacts are not isolated.
Low Profile Selection Switch
10 A Relay Contacts
LED Status Indication
V = Voltage LA = Load A LB = Load B
Industry Standard Base
S1 = Primary Control Switch S2 = Lag Load Switch
Connection
Dashed lines are internal connections.
Mounting and Connection Note: S1 and S2 must be rated for the Load
Accessories (LA & LB) voltage and current.

Technical Data
35mm DIN rail or Output
surface mounting 10 A resistive at 120/240 V AC and 28 V DC;
Rating
1/3 hp at 120/240 V AC
Mechanical
Mounting and Connection 35mm or surface mounting, requires an accessory 8 pin (Octal) socket
Package 3.2 x 2.39 x 1.78 in. (81.3 x 60.7 x 45.2 mm)
LLC-ARPpp

P/N: PHST-38QTN Ordering Table


Part Number Voltage Function Adjustment
ARP43S 120 VAC Cross Wired Duplexor Selector Switch
01.07.08

See accessory pages

Low Voltage Products & Systems 35


ABB Inc. • Sales Information 1-888-385-1221 • Technical Assistance 1-800-377-SSAC (7722) • www.ssac.com 1TRC001022C0201
rin
g Liquid Level - Motor Winding Temperature Monitors
t o
i ys
on CM-ENS UP/DOWN / CM-MSS
M Rela
SPDT (c/o) Relay Output

The CM-ENS UP/DOWN monitors levels of conductive liquids, and is used for liquid level
control in pump systems.
The CM-ENS senses the difference in the resistance of the liquid and air, to determine the liquid level.
The output relay’s function fill (UP) or drain (DOWN) is switch selectable. If the “UP” function is selected,
the output relay is energized until the liquid touches the upper probe. If the “DOWN” function is
selected, the output relay energizes until the liquid level falls below the Min probe.

1 Function Selector Switch:


UP - Fill
DOWN - Drain
2 Adjustable Sensitivity from 5 to Function
100K ohms
3 R: Yellow LED - Relay Status
4 U: Green LED - Input Voltage MAX
5 Compact Package MIN
C
A1-A2
“DOWN” 11-14
11-12
“UP” 11-14
11-12
Monitoring and control of
When using a metal tank the C electrode is not required.
conductive liquids
In this case the cable can be connected directly to the
Selectable function “fill”
metal surface of the tank.
or “drain”
Adjustable sensitivity 5 - 100 KΩ
1 SPDT (c/o)
2 LED‘s for status indication Technical Data Connection
A1 11 A1 - A2 Input voltage
Output C MAX MIN C Ground reference
Rating - AC12 (resistive) 230 V 4A C MAX MIN 11 electrode
Rating - AC15 (inductive) 230 V 3A MAX Maximum level
MIN Minimum level
Mechanical
11-12/14 Output contacts
Dimensions 3.94x3.07x0.89 in (100x78x22.5mm) A1 A2 12 14
Degree of Protection Enclosure IP50 / Terminals IP20
14 12 A2
Ordering Table
Part Number Series Input Voltage
1SVR 430 851 R0200 CM-ENS UP/DOWN 110-130 V AC

CM-MSS (2) Thermistor Motor Protection Relay - 1 PTC Sensor Circuit


The CM-MSS (2) is designed to protect motor connected in series with terminals T1 and T2. When
windings from overheating and failure by the total resistance exceeds 1.5 K ohms the output
sensing the temperature with an embedded de-energizes and latches (non-volatile). The unit
PTC thermistor. Selection of the protection is reset with the onboard or an accessory external
relay is independent of motor size, Hp rating, reset switch. Automatic reset is selected by adding a
insulation class and starting method. jumper from X1 to T1.
The three or more PTC winding sensors are
Connection
1 Manual Reset Button
2 F: Red LED - Fault Tripped A1 - A2 Input Voltage
3 U: Green LED - Input Voltage Applied T1 - T2 Sensor Circuit
4. 2 SPDT (2 c/o) Output Contacts S1 - T2 Remote Reset
5. Compact package X1 - T2 Jumper = Automatic
Reset
11 -12/14 Output Contacts
21 - 22/24 Normally Engergized

1 PTC Circuit
Automatic or Manual Reset
Broken Wire Detection Technical Data
Remote Reset Terminals Output
2 SPDT (2 c/o) Contacts
01.17.08

Rating Res. 4 A / Ind. 3 A


2 LED’s for Status Indication M Motor
Mechanical
22.5 mm wide enclosure, Dimensions 3.94 x 3.07 x 0.89 in. (100 x 78 x 22.5 mm)
35mm DIN Rail Mounting Degree of Protection Enclosure IP50 / Terminals IP20
ENS-MSSpp

Ordering Table
Part Number Series Input Voltage
1SVR 430 811 R9300 24 V AC
CM-MSS
1SVR 430 811 R0300 110 130 V AC

36 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
&
er tion
Tower and Obstruction Lighting Controls
w
To truc ng Controls for Incandescant and LED Lamps
s ti
Ob Ligh Flashers, Photo Control, Alarm Relays

Flasher — Solid State Beacon Flasher


Part Number Voltage Note Description

FS155-30RF 2500 W Beacon Flasher for High RF Installations


(200 A Inrush Maximum)
Meets FAA-AC Beacon Flasher for FM, TV, Chimneys, Bridges,
FS155-30T FS-155-30T No. 150/5345-43E Smoke Stacks, and Low RF Applications
120 V AC
Auxiliary Unit for Synchronous
FA155-2
2500 W Flashing of Additional Beacons
(200 A Inrush Maximum) Auxiliary Unit Provides Alternate Operation
FA155
for Constant Line Loading

FA155-2

Photo Control — Accurate Dusk to Dawn Control


Part Number Voltage Note Description

Precision Photo Control Calibrated to FAA and FCC Specifications


Meets FAA-AC
PCR10 120 V AC for Tower and Obstruction Lighting. Two SPST N.O. 20 A Contacts.
No. 150/5345-43E
Without Cast Aluminum Housing.

PCR10

Lamp Alarm Relays — Senses Lamp Failure


Part Number Voltage Note Description

Universal Light Alarm Relay;


Senses the Failure of One Lamp Out of 1, 2, 3, or 4 Lamps;
SCR430T 120 V AC
116 or 620 W, 120 V AC Incandescent Lamps;
Meets FAA-AC SPDT - 10 A Isolated Alarm Contacts.
No. 150/5345-43E
SCR430T Universal LED Lamp Alarm Relay;
Senses the Failure of 1 Lamp out of 1 to 8 Lamps;
SCR9L 120/230 V AC
Works with LED Beacons or Side Lamps;
Monitors
1 to 8 LED 1 SPDT & 1 SPNO Alarm Contacts.
Beacons
or LED
Side Lamps
SCR9L

Beacon Alarm Relay — Senses Lamp Failure and Flasher Failure

Part Number Voltage Note Description

Flasher and Incandescent Beacon Lamp Alarm Relay;


Senses Failure of Incandescent Beacon Lamps and Beacon Flasher;
FB120A 120 V AC
Two Line Voltage Alarm Outputs;
SPDT - 10 A Isolated Alarm Contacts
Meets FAA-AC
FB120A No. 150/5345-43E Universal LED Beacon Lamp & Flasher Alarm Relay;
Senses failure of 1 lamp out of 1 to 8 LED Beacons;
FB9L 120/230 V AC
1 SPDT & 1 SPNO Alarm Contacts;
0.5A Solid State Bypass Relay Output
Monitors
1 to 8 LED
Beacons;
Monitors
FB9L Flasher
Operation
TWRpp
01.04.08

Low Voltage Products & Systems 37


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
Accessories
ries
s so Mounting and Connection Sockets
ce
Ac

DIN Rail or Surface Mount Sockets


8 Pin Octal Socket (600 VAC)
P/N: OT08PC
8 pin 35 mm DIN rail or surface mount socket. OT08PC is rated at 10 A at 600 V AC and has pressure clamp terminals.
Select this socket for use with plug in three phase voltage monitors. For use with AWG 12 to 22 (3.2 to 0.33 mm2) wire
sizes. Hold-down clips not available.
Dimensions:
1.60 W x 2.1 l x .97 h in. (40.6 x 53.3 x 24.6 mm)

8 Pin Octal Socket (300 VAC)


P/N: NDS-8
May be surface mounted with two #6 (M 3.5 x 0.6) screws or snaps onto a 35 mm DIN rail. A spring mechanism
allows easy removal. Screw terminals with captive wire clamps accept up to two #14 AWG (2.45 mm2) wires. Rated
10 A at 300 V AC. Uses PSC8 hold-down clips.
Dimensions:
1.60 W x 2.03 x .85 h in. (40.6 x 51.6 x 21.6 mm)

11 Pin Magnal Socket


P/N: NDS-11
May be surface mounted with two #6 (M 3.5 x 0.6) screws or snaps onto a 35 mm DIN rail. A spring mechanism allows
easy removal. Screw terminals with captive wire clamps accept up to two #14 AWG (2.45 mm2) wires. Rated 10 A at 300
V AC. Uses PSC11 hold-down clips.
Dimensions:
1.80 W x 2.03 x 1.25 h in. (45.7 x 51.6 x 31.8 mm)

Hold-Down Clips
P/N: PSC8
PSC11
Securely mounts plug in controls in any position. Also provides protection against vibration. Select the PSC8
for use with NDS-8 or the PSC11 for use with NDS-11 sockets. Comes in sets of two.

Surface Mount Sockets


8 Pin Octal Socket (600 VAC)
P/N: P1011-6
8 pin surface mount socket with binder head screw terminals. Rated 10 A at 600V AC. Select this socket for use
with plug in three phase voltage monitors. When used with TDM, TDB, TDS Series timers the combination is UL
Listed. Uses PSCRB8 hold-down brackets.

Hold-Down Brackets
P/N: PSCRB8
Designed for use with P1011-6 socket. Securely mounts 8 pin plug-in controls in any position, and
01.07.08

provides protection against vibration. Comes in sets of two.


Dimensions:
2.0 W x 2.25 x .63 h in. (50.8 x 57.2 x 15.9 mm)
Socketpp

38 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
Accessories
ries
s so Mounting Methods,
ce
Ac Timer Adjustments and Dials

Front Panel Mount Kit


P/N: BZ1
Provides an easy method of through-the-panel mounting
of 8 or 11 pin plug-in timers, flashers, and other controls.
May be mounted in panels up to 0.125 in. (3.2 mm) thick.
Includes two clamps and two screws.

Inches (Millimeters)
Illustrates panel opening size
required to mount BZ1.

← (52.0


DIN Rail Mount Adaptor 0.8

(5 .0
)

8)
2
0.
P/N: P1023-20 ←
Allows any 2 x 2 in. (50.8 x 50.8 mm) or 2 x 3 in. (50.8 x 76.2 mm) module to be


mounted on a 35 mm DIN type rail. Comes complete with mounting hardware for
0.75 in. (19 mm) and 1 in. (25.4 mm) thick modules. ← 1.0
(25 ←
.4)

←1 Mounting hole for


.25 #8 (M4 X 0.7) bolt
(31 ←
.8)
Inches (Millimeters)

P/N: P1004-95-X

Versa-Pot
Panel mountable, industrial potentiometer recommended for remote time delay adjustment. The shaft
is slotted for screwdriver adjustment and serrated for slip-proof finger adjustment. Accepts Versa-Knob
or Lock Shaft. May be ordered with two 8 in. (20.3 cm) wires soldered to pot (clockwise increase) and
female quick connect terminals on other ends by adding suffix -X to end of part number.
P/N: P1004-95
Ordering Table
Part Number Value (Ohms) With Wire Leads
P1004-95 No
100 K
P1004-95-X Yes

Technical Data
Rating 0.25W at 55°C
Taper Linear
Shaft Rotation 300° +/-5° Inches (Millimeters)
Tolerance +/-10%

Versa-Knob
P/N: P0700-7
Versa-Knob is designed for 0.25 in (6.35 mm) shaft of Versa-Pot or
Q-Pot. Semi-Gloss industrial black finish.

Time Adjustment Dials


Dials for use with remote Versa-Pot. Reverse screen printed on clear
plastic to avoid damage to printed image.

Ordering Table
Part Number Range Increments
P0400-82 0.1 ... 10s 1s
Mountspp

P0400-26 0.1 ... 10m 1m


SS = Set Screw
P0400-27 0 ...10 Reference Dial
Inches (Millimeters)
01.17.08

Low Voltage Products & Systems 39


ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm 1TRC001022C0201
Accessories
ries
s so Liquid Level Probes and Probe Holders
ce
Ac

Liquid Level Control Electrodes


Designed for use with all conductive liquid level controls. Composed of
insulators and metal parts made of number 300 series stainless steel.
These internally conductive probe holders are designed for a maximum
steam pressure of 240 PSI.

Ordering Table
Part Number Description
PHST-38QTN Probe Holder (UL Recognized)
P0700-409 Protective Boot

Inches (Millimeters)

Inches
Liquid Level Probe
(Millimeters) Inches (Millimeters)
P/N: LLP-24
Threaded stainless steel probe measuring 24 in. (61 cm)
long. Designed for use with PHST-38QTN liquid level control
electrodes.

Suspension Electrode
Steel electrode (X 12 CR Mo S 17) with sleeve (Lupulen 6011 L) suitable
up to 60°C max. Attaches to an insulated wire suspended from the top
of the holding tank. Length of wire determines the sensing location.

Ordering Table
Part Number Units per pack Weight (kg/oz)
1SVR 402 902 R 0000 1 0.053/1.855

Three Phase Fuse Block/Disconnect

06.11.08
Three phase fuse block disconnect designed for use with HRC
midget fuses rated up to 25 A at 500 V AC. Snap onto 35mm DIN rail.
←→
2.32
(59)

LLCACCpp

Midget Fuse
(52 .07 →

Fast acting fuse for use with voltage monitors. Rated ← 3.0
.5)

(78 7

2

2 A at 500 V AC. 1.5 x .41 in. (38.1 x 10.4 mm) ) →


FH3P does not include P0600-11 fuses
Ordering Table
Part Number Description
FH3P 3 Pole Fuse Block
P0600-11 Midget Fuse

40 Low Voltage Products & Systems


1TRC001022C0201 ABB Inc. • Sales Sales & Technical Information 1-888-385-1221 8AM to 5PM CST - Product Information www.ssac.com/pp1.htm
Express Timers & Controls
x All Part Numbers are
de Part Number Index
In unless marked QS ( )

ABB & SSAC Express Part Numbers

Part Number Page Part Number Page Part Number Page


1SVR 402 902 R0000...............................................40 FS127.......................................................................23 P0700-409................................................................40
1SVR 430 750 R0400...............................................30 FS146.......................................................................23 P1004-95..................................................................39
1SVR 430 760 R0400...............................................34 FS155-30RF.............................................................37 P1004-95-X..............................................................39
1SVR 430 760 R0500...............................................34 FS155-30T................................................................37 P1011-6....................................................................38
1SVR 430 811 R0300...............................................36 HLMUDRAAA...........................................................24 P1023-20..................................................................39
1SVR 430 811 R9300...............................................36 HRPS/HRIS...........................QS................................7 PCR10......................................................................37
1SVR 430 824 R9300...............................................28 HRPU/HRIU...........................QS................................8 PHST-38QTN............................................................40
1SVR 430 830 R0300...............................................29 KRPD.....................................QS................................3 PLMU11...................................................................26
1SVR 430 830 R0400...............................................29 KRPS.....................................QS................................2 PSC8........................................................................38
1SVR 430 831 R0300...............................................29 KSD1420..................................................................21 PSC11......................................................................38
1SVR 430 831 R0400...............................................29 KSD1421..................................................................21 PSCRB8...................................................................38
1SVR 430 840 R0200...............................................33 KSD1423..................................................................21 RS..........................................QS..............................23
1SVR 430 840 R0300...............................................33 KSD1430..................................................................21 SCR9L......................................................................37
1SVR 430 840 R0400...............................................33 KSD1431..................................................................21 SCR430T..................................................................37
1SVR 430 840 R0500...............................................33 KSD1433..................................................................21 TCSA5......................................................................32
1SVR 430 841 R0200...............................................33 KSD2420..................................................................21 TCSA10....................................................................32
1SVR 430 841 R0300...............................................33 KSD2421..................................................................21 TCSA20....................................................................32
1SVR 430 841 R0400...............................................33 KSD2423..................................................................21 TCSA50....................................................................32
1SVR 430 841 R0500...............................................33 KSD2430..................................................................21 TCSGAA...................................................................32
1SVR 430 851 R0200...............................................36 KSD2431..................................................................21 TCSGAB...................................................................32
1SVR 500 020 R0000...............................................16 KSD2433..................................................................21 TCSHAA...................................................................32
1SVR 500 020 R1100...............................................16 KSDB420..................................................................21 TCSHAB...................................................................32
1SVR 500 100 R0000...............................................15 KSDB421..................................................................21 TDB24AL..................................................................14
1SVR 500 110 R0000...............................................20 KSDB423..................................................................21 TDB120AL................................................................14
1SVR 630 020 R0200...............................................18 KSDB430..................................................................21 TDI120AL..................................................................14
1SVR 630 120 R3300...............................................20 KSDB431..................................................................21 TDM12DL.................................................................14
Accessories..............................................................38 KSDB433..................................................................21 TDM24AL.................................................................14
ARP43S....................................................................35 KSDS420..................................................................21 TDM120AL...............................................................14
BZ1 . ........................................................................39 KSDS421..................................................................21 TDMH120AL.............................................................14
CM-EFS....................................................................30 KSDS423..................................................................21 TDML12DL...............................................................14
CM-ENS up / down..................................................36 KSDS430..................................................................21 TDML120AL.............................................................14
CM-ESS....................................................................29 KSDS431..................................................................21 TDR..........................................QS...........................15
CM-MSS...................................................................36 KSDS433..................................................................21 TDS120AL................................................................14
CM-PFS....................................................................28 KSPD.....................................QS................................5 TDU3000A................................................................22
CM-SFS....................................................................34 KSPS.....................................QS................................4 TDU3001A................................................................22
CM-SRS...................................................................33 KSPU.....................................QS................................6 TDUH3000A.............................................................22
CT-AHD....................................................................20 LCS10T12.................................................................31 TDUH3001A.............................................................22
CT-ARS.....................................................................20 LLC54AA..................................................................35 TDUL3000A..............................................................22
CT-ERD.....................................................................15 LLC54BA..................................................................35 TDUL3001A..............................................................22
CT-MFD....................................................................16 LLP-24......................................................................40 TMV8000..................................................................22
CT-MVS....................................................................18 LPM12......................................................................31 TRDU24A2................................................................12
DLMUBRAAA...........................................................25 LPMG12...................................................................31 TRDU24A3................................................................12
ECS40BC.................................................................31 NDS-8.......................................................................38 TRDU120A1..............................................................12
ECS41BC.................................................................31 NDS-11.....................................................................38 TRDU120A2..............................................................12
FA155.......................................................................37 OT08PC....................................................................38 TRDU120A3..............................................................12
FA155-2....................................................................37 P0400-26..................................................................39 TRU1........................................................................11
FB9L.........................................................................37 P0400-27..................................................................39 TRU2........................................................................11
FB120A.....................................................................37 P0400-82..................................................................39 TRU3........................................................................11
FH3P.........................................................................40 P0400-XX.................................................................39 WVM911AH..............................................................27
FS126.......................................................................23 P0600-11..................................................................40 WVM911AL...............................................................27
FS126RC..................................................................23 P0700-7....................................................................39

Terms of Sale
InBkCv

1.) Same day factory shipment on orders received before 3:00 PM EST, M-F
10.08.08

2.) Typical maximum quantity is 25 units. Call factory for lead times on higher quantities.
3.) Minimum factory order amount is $100.00 USD or ship via Next Day Air Shipping Method. See www.abb-control.com for your local ABB Authorized Distributor.
4.) Payment arrangements must be made in advance. Contact Customer Service.

1.) Shipment in two business days on orders received before 3:00 PM EST, M-F
2.) Typical maximum quantity is 25 units. Call factory for lead times on higher quantities.
3.) Minimum factory direct order amount is $100.00 USD. See www.abb-control.com for your local ABB Authorized Distributor.
4.) Payment arrangements must be made in advance. Contact Customer Service.
Publication 1TRC22
No. 1TRC001022C0201
Printed in USA, February, 2008

ABB Inc., SSAC Products, 888-385-1221 8:00AM to 5:00PM CST, M-F; Product Information: www.ssac.com , Find Local ABB Authorized Distributors: www.abb-control.com
Printed in USA, February, 2008
No. 1TRC001022C0201
Publication 1TRC22

Sales Information: Sales Information (Canada)


ABB Inc. ABB Inc.
1206 Hatton Road 2117 32nd Avenue
Wichita Falls, TX 76302 Lachine, Quebec H8T 3J1
Telephone 888-385-1221; 940-397-7000 Canada
Fax 940-397-7085
http://www.abb-control.com Telephone
USA Technical Help 888-385-1221 option 4, 8:00AM to 5:00PM CST, M-F Atlantic & Quebec Region: 800-567-0283
Find USA ABB Authorized Distributors: www.abb-control.com Ontario Region: 866-460-3300
SSAC Product Information: http://www.ssac.com Mid-West & Pacific Region: 866-222-8368

You might also like