There is a total of four run in this experiment with different temperature set which is
(30, 40, 50, and 60) °C with the use of heater to obtain the temperature increasing.
After that, the millivolt of thermocouple is collected from the references tables by
using linear interpolation formula. Then, measure the signal output and calculate the
actual signal before we can calculate the actual temperature. The experiment is done
in two set to obtain the average value.
From all table result, it shows the different in deviation range in term of temperature
for the three types of instrument were used, we can see that the average temperature
deviation is increasing when the measured temperature increase from 30 ºC to 60 ºC
From the result obtained RTD has the lower deviation temperature in the range
followed by Type J and Type K. This result obtained says that RTD is more accurate
compare to other thermocouple. The smaller the deviations, the higher the accuracy of
instruments. This deviation may due to some error of instrument or human error
during conducting the experiment.
There are some errors during conducting this experiment. The first one is the way
handling the multi-meter. Next, thermocouple and RTD sensor might be faced the
sensor error and the circulation pump can be the error due to under range data
collected. In addition, heater cannot heat the water at high capacity due to lack of
power to generate and lastly, the wind disturbance might disturb the data collection.