You are on page 1of 40

Introducing PolySNAP 2

1 Bruker Confidential 02/11/2007


Introducing
PolySNAP 2

 PolySNAP 2 is the successor product to the groundbreaking PolySNAP

 PolySNAP provided powerful cluster analysis tools and clean, elegant


and informative graphic displays to allow for high-throughput analysis
of Powder X-Ray Diffraction patterns.

 PolySNAP 2 has the same powerful tools, but allows them to be


employed to ANY kind of numeric data
• PXRD, Raman, IR, DSC, Melting Points…. Anything!

 PolySNAP 2 allows up to four different datasets to be analysed


simultaneously
• (or a single dataset with up to four different processing options)

 PolySNAP 2 combines the results from individual datasets to show the


overall picture of what’s going on

2 Bruker Confidential 02/11/2007


Multiple Datasets

 Combined XRPD + Raman instruments now available – D8 Spectrolab

 Applying multiple techniques to the same samples helps give


additional information to work with

 How would we actually combine results from two such different


techniques ?

 Automatically calculate optimal weighting for each entry in each


dataset
• Much more powerful than manually averaging results

3 Bruker Confidential 02/11/2007


Methodology
- PXRD + Raman

n Full profile matching nxn nxn XRD results

all patterns against all patterns Correlation Distance


XRPD
Matrix Matrix Combined
Patterns
results

nxn
Combine Distance
Matrix

n Full profile matching nxn nxn


all patterns against all patterns Correlation Distance
Raman Raman
Matrix Matrix
Patterns results

4 Bruker Confidential 02/11/2007


5 Bruker Confidential 02/11/2007
6 Bruker Confidential 02/11/2007
Run on…
a single dataset

 Just like PolySNAP:


» - but can now select different kinds of input

» - Separate automatic pre-processing defaults for


each type of data
» - also new is the ability to transform spectra
» - either Fourier transform or derivative (1st or 2nd)

» - can also specify a location to load sample image


files from (JPEG files)

7 Bruker Confidential 02/11/2007


Analysis Tools:
Dendrogram
 Similar patterns are clustered together
 Position of ‘Cut-Level’ partitions the data into separate clusters

Too high?

Too low?

Just right

 Adjust the cut-level to best


describe the data

8 Bruker Confidential 02/11/2007


Analysis Tools:
3D MMDS Plot

 Each sphere is a pattern


 The closer together two spheres are, the more similar they are
 Similar patterns ‘clump’ together
 Different patterns are far apart
 Easy to spot outliers at a glance

 As with all PolySNAP graphics, you can:


• Zoom in, zoom out, rotate
• Hide and show and drag labels
• Change rendering quality
• Change colour of background, axes etc.
• Produce figures for publication

9 Bruker Confidential 02/11/2007


Multiple Methods:
Consistent Colouring
 Changing the clustering
in the dendrogram
automatically updates
the colours in the other
plots.

 Cluster colours from dendrogram


are used on MMDS plot so you can
compare the groupings from both
methods. Same results from both
increases confidence in the
accuracy of the results.

10 Bruker Confidential 02/11/2007


Analysis Tools:
Quantitative Analysis

 Given reference phases, PolySNAP can identify possible mixtures and


perform fast quantitative analysis. Results are shown on the Cell
Display in the form of Pie Charts or Stacks.

11 Bruker Confidential 02/11/2007


Analysis Tools:
Cell Display

 Cell Display is also


useful for seeing the
clustering result
colours superimposed
on e.g. the layout of
an original 96 well
plate from a high-
throughput system.

12 Bruker Confidential 02/11/2007


Analysis Tools:
6D Plots –Sample Preparation Information

 Automatically read sample preparation information from data file


headers or standalone CSV file
 Plot any combination of this information as different variables in the
3D plot – vary size, shape and colour of plotted points
 e.g. show different solvents as different
shapes
 Vary the shape size with temperature,
the colour with time
 See what initial variables correlate to
resulting materials

13 Bruker Confidential 02/11/2007


Analysis Tools:
Validation

 Check the validity of the clustering using powerful statistical tests


• Silhouettes – are these cluster memberships reasonable?
• Fuzzy Clustering – should this pattern be in a different cluster?
• Scree plots – how many clusters are needed to explain the data?
• Minimum Spanning Trees – an alternative way to construct clusters
 Silhouettes example:
• Pattern 21 scores poorly as a member of this cluster
• it is the least tightly connected in the dendrogram
• This turns out to be a mixture, rather than a pure phase

14 Bruker Confidential 02/11/2007


Analysis Tools:
High Dimensionality Viewers

 Advanced visualisers to test if the clustering holds true in higher


dimensional space
 Animated dataset ‘Grand Tour’
 Parallel Coordinates Plots
 Space Explorer View

15 Bruker Confidential 02/11/2007


Run on…
Multiple Datasets

 3 potential ways of working with PolySNAP 2…

 1. Multiple types of data have been collected on the same samples


• e.g. there is a set of 96 samples, from which have been collected both
PXRD and Raman spectra
• Examine the clustering from the PXRD, and the Raman, and the combined
PXRD + Raman
o Do the different methods agree? Do they contradict each other?

 2. Multiple instances of the same type of data collected


• e.g. PXRD patterns collected on the same samples at different times, or
under different conditions

 3. Investigate a single dataset under different processing options


• Compare side-by-side what difference turning background subtraction, etc.
on makes to the final results

16 Bruker Confidential 02/11/2007


Run on…
Multiple Datasets
Select
PXRD and Select
choose data Raman and
location choose data
location

Select any
different
processing
options for
each
dataset Click OK to
start

17 Bruker Confidential 02/11/2007


How much data?

 For each individual dataset, PolySNAP 2 can analyse up to 1,500


samples at once
 Up to four different datasets can be input for each run
 The datasets can be any combination of:
• PXRD
• Raman
• DSC
• IR
• Other spectra data
• Numeric
o Numeric can be a correlation matrix, or ‘raw’ numeric data relating to the samples
being analysed
– e.g. Melting points

 Data formats: RAW, Powder-CIF, ASCII, CSV, Raman SPC, Opus

18 Bruker Confidential 02/11/2007


Results Screen

19 Bruker Confidential 02/11/2007


Results Screen

Click on the dataset


name to switch
between different sets
of results – here,
choose between
PXRD and Raman
individually, or the
combined results

20 Bruker Confidential 02/11/2007


Results Screen

Click on the tabs to


see different display
screens to help you
interpret the results

21 Bruker Confidential 02/11/2007


Results Screen

Select a sample or
samples in the results
Click the vertical tabs screen to see
to switch between information about it
seeing the PXRD or and its profile
Raman profile for the displayed below
currently selected
patterns

22 Bruker Confidential 02/11/2007


Results Screen

 Compare the clustering results from each datatype in turn

23 Bruker Confidential 02/11/2007


Results Screen

» Look at both the PXRD and Raman spectra to make sure this
clustering looks sensible

24 Bruker Confidential 02/11/2007


Results Screen
Or select up to four
multiple datasets to view
results side by side…

25 Bruker Confidential 02/11/2007


Multiple Screens
Multiple Windows

 Customers with multiple monitors can open separate results screens


on each one, allowing easy comparison of different results side-by-
side

26 Bruker Confidential 02/11/2007


Combined Datasets
Example 1

 48 patterns of 3 forms of Sulfathiazol (forms 2, 3 and 4)


 PXRD and Raman data collected

 PXRD Data only:


• Splits form 3 into 2 separate clusters

Form 4 Form 3 Form 2 Form 3


27 Bruker Confidential 02/11/2007
Combined Datasets
Example 1

 48 patterns of 3 forms of Sulfathiazol (forms 2, 3 and 4)


 PXRD and Raman data collected

 Raman Data only:


• Doesn’t distinguish between Form 3 and Form 4

Forms 3 & 4 Form 2

28 Bruker Confidential 02/11/2007


Combined Datasets
Example 1

 48 patterns of 3 forms of Sulfathiazol (forms 2, 3 and 4)


 PXRD and Raman data collected

 Combined PXRD + Raman using Automatic Weights:


• Does much better than the individual methods alone

Form 4 Form 3 Form 2

29 Bruker Confidential 02/11/2007


Combine Results
Example 2

 46 patterns of 2 anhydrous forms of Carbamazepeine (Forms 1 & 3)


 PXRD and Raman data collected

 PXRD Data only:


• E3 and F7 in different clusters

30 Bruker Confidential 02/11/2007


Combine Results
Example 2

 46 patterns of 2 anhydrous forms of Carbamazepeine (Forms 1 & 3)


 PXRD and Raman data collected

 Raman Data only:


• E3 and F7 in same cluster!

31 Bruker Confidential 02/11/2007


Combine Results
Example 2

 46 patterns of 2 anhydrous forms of Carbamazepeine (Forms 1 & 3)


 PXRD and Raman data collected

 PXRD&Raman Data Combined:


• F7 highlighted as an outlier due to this inconsistency
»

» Other outliers (yellow) are


mixtures of the 2 forms

32 Bruker Confidential 02/11/2007


Combined Results

 Matching method does very well in distinguishing forms automatically


using either Raman or PXRD data
 Combined results using Automatic Weights seem to do better than
either PXRD or Raman individually
 Identification of pure phases / mixtures improved
 Use of combined data highlights any inconsistencies in separate
analyses
• Sunch inconsistencies would not be obvious with only one data source
• User can then examine outliers manually in detail
 Seeing similar clustering from multiple original data sources increases
confidence in the results

33 Bruker Confidential 02/11/2007


Quality Control

 Given a set of reference patterns, new patterns can be considered to


be similar enough to the references to ‘pass’, or different enough to
‘fail.’
 Graphical representation:
new samples within the green
Pass surface are OK, samples
falling outside the surface fail.

34 Bruker Confidential 02/11/2007


Other Features

 Automatic Report Writer


 Ability to run from command line - launch analysis as part of a script
 Integration with other Bruker software
 Audit-trail detailed logfile
 Raw numeric results available for interrogation
 Results automatically archived to encrypted file
 Full manual and tutorial provided
 View sample images alongside patterns
 Manual analysis mode:
• Compare one pattern to many
• Detailed numeric breakdown of results

35 Bruker Confidential 02/11/2007


Dealing with
Large Datasets

 Specially designed tools for dealing with large, complex datasets


 Select subsets for re-analysis
 View simplified dendrograms and 3D plots
 Show/Hide selected clusters
 Hide all but current cluster being investigated
 Transparency options
 Search options locate individual patterns of interest

36 Bruker Confidential 02/11/2007


PolySNAP M

 Ideal for single, smaller datasets (up to 96 patterns)


 PolySNAP M has dendrograms, 3D plots, and manual analysis mode

37 Bruker Confidential 02/11/2007


Which PolySNAP
Do I Need?
PolySNAP M PolySNAP 2
Program Type Commercial Commercial
Input Data Types Powder XRD PXRD, Raman, DSC, IR, Numeric, Other
Max No. Of Samples per run 96 4x 1500
6D plots of sample prep info No Yes
Sample JPEG display No Yes
Cluster Validation Tools No Yes
Report Writer No Yes
Re-run selected analysis No Yes
No. of clustering methods 1 5
Online documentation Yes Yes
Program Tutorial Yes Yes
Customisable Analysis Methods No Yes
Manual Matching Options Yes Yes
Interactive Dendrograms Yes Yes
3D MMDS Plots Yes Yes
3D PCA Plots Yes Yes
Numerical Results Yes Yes
Audit-trail Logfile Yes Yes
Amorphous Identification Yes Yes
Reference patterns for mixtures Yes Yes
Command-line run options No Yes
Quality Control mode No Yes
Combine multiple datasets No Yes
Multiple Monitor Support No Yes

38 Bruker Confidential 02/11/2007


Support Services

 Training
• One and two-day in-depth training packages available
• Gain detailed knowledge of advanced program functions
• Use advanced options with trickier datasets with confidence
• Look at your own data with

 Customisation
• personalised modifications to suit company-specific workflows
• Interface alterations
• Integration with other custom-software

39 Bruker Confidential 02/11/2007


www.bruker-axs.com
www.chem.gla.ac.uk/snap

40 Bruker Confidential 02/11/2007

You might also like