Magnetic Particle Inspection Report

Client: IAL / IAL/ Massy Energy Attention: Mr. H Singh


Engineered Solution Ltd
Project: Relief Nipple Date (dd/mm/yyyy): 20/01/2016
Job Location: IAl Facility San Fernando Inspection Date (dd/mm/yyyy): 20/01/2016
Ticket No.:
Job No.: 16-0082 Report No.: IA10815

Job Description: To perform Visual and Magnetic Particle Inspection on:

1. One (1) Pressure Relief Tool 1/2" LP, Nipple


 Job No: 15MMM1766I
 SN: 15MMM1766I
 PN: 13985-06 Rev. 0
 HT: 140070

Acceptance Criteria: Equipment: Magnetic Lift Load:


API RP7G-2 API RP7G-2 DC Coil:RC3-61820122 N/A

Material: B. Inten. (µW/cm²): Light Dist. (inches): P. Con.(ml/100ml):


4140 80 KSI 2001 (SN:1883362/4) 15 0.25
Background: Particle: Technique: Field Adequacy and
Direction:
Natural Fluorescent Particle Longitudinal Indirect Magnetic Particle Field
(20B Batch#: 13K085) Method Indicator
Results:
At the time of inspection, no relevant indications were found and parts inspected were acceptable to code.

Inspected by: _______________________


Mr. Hayden Xavier
SNT-TC-IA Level II

Page 1 of 1 Doc. Ref. - ROSL/017


Rapid Oilfield Services Limited
#51 Market Steet, Gopaul Lands, Marabella, Trinidad, W.I.
Tel./Fax: (868) 221-2643 Cell: (868) 682-2911/384-5571
e-mail: admin@rapidoilfield.com

Magnetic Particle Inspection Report

Client: IAL/ IAL/ Massy Energy Engineered Attention: Mr. H. Singh


Solution Ltd

Project: Coupling Date (dd/mm/yyyy): 18/01/2016

Job Location: IAL Facility, San Fernando Inspection Date (dd/mm/yyyy): 18/01/2016

Ticket No.:

Job No.: 16-0069 Report No.: IA10726

Job Description:

To perform Visual and Magnetic Particle Inspection on:


1. 3/4” LP, Coupling

 Job No.: 15MMM1766G


 SN: 15MMM1766G
 PN: 13985-06 Rev. 0
 H.T.: 222148

Procedure: Acceptance Criteria: Equipment: Magnetic Lift Load


API RP7-G-2 (ASNT API RP7-G-2 (ASNT DC Coil(1123072C) / -
Level III Approved) Level III Approved)
Material: B. Inten. (µW/cm²): Light Dist. (inches): P. Con.(ml/100ml):
4140 110KSI 2130 (1859254/5) 15 0.3
Background: Particle: Technique: Field Adequacy and
Direction:
Natural Fluorescent Particle Longitudinal / Indirect Magnetic Particle Field
(20B Batch#: 15D074) Method Indicator
Results:
At the time of inspection, no relevant indications were found and all areas inspected were acceptable to code.

Inspected by: _______________________


Mr. Ancil Owen
SNT-TC-IA Level II
Doc. Ref. - ROSL/017
Rapid Oilfield Services Limited
#51 Market Steet, Gopaul Lands, Marabella, Trinidad, W.I.
Tel./Fax: (868) 221-2643 Cell: (868) 682-2911/384-5571
e-mail: admin@rapidoilfield.com

Magnetic Particle Inspection Report

Client: IAL/ Massy Energy Engineered Attention: Mr. H. Singh


Solution Ltd

Project: Stem, Pressure Relief Tool Date (dd/mm/yyyy): 18/01/2016

Job Location: IAL Facility, San Fernando Inspection Date (dd/mm/yyyy): 18/01/2016

Ticket No.:

Job No.: 16-0069 Report No.: IA10725

Job Description:

To perform Visual and Magnetic Particle Inspection on:


1. 3/4” -10 UN, Stem, Pressure Relief Tool

 Job No.: 15MMM1766D


 SN: 15MMM1766D
 PN: 13985_03 Rev. 0
 H.T.: 334413

Procedure: Acceptance Criteria: Equipment: Magnetic Lift Load


API RP7-G-2 (ASNT API RP7-G-2 (ASNT DC Coil(1123072C) / -
Level III Approved) Level III Approved)
Material: B. Inten. (µW/cm²): Light Dist. (inches): P. Con.(ml/100ml):
410 Stainless Steel 2130 (1859254/5) 15 0.3
Background: Particle: Technique: Field Adequacy and
Direction:
Natural Fluorescent Particle Longitudinal / Indirect Magnetic Particle Field
(20B Batch#: 15D074) Method Indicator
Results:
At the time of inspection, no relevant indications were found and all areas inspected were acceptable to code.

Inspected by: _______________________


Mr. Ancil Owen
SNT-TC-IA Level II
Doc. Ref. - ROSL/017
Rapid Oilfield Services Limited
#51 Market Steet, Gopaul Lands, Marabella, Trinidad, W.I.
Tel./Fax: (868) 221-2643 Cell: (868) 682-2911/384-5571
e-mail: admin@rapidoilfield.com

Magnetic Particle Inspection Report

Client: IAL/ IAL/ Massy Energy Engineered Attention: Mr. H. Singh


Solution Ltd

Project: Bonnet, Pressure Relief Tool Date (dd/mm/yyyy): 18/01/2016

Job Location: IAL Facility, San Fernando Inspection Date (dd/mm/yyyy): 18/01/2016

Ticket No.:

Job No.: 16-0069 Report No.: IA10724

Job Description:

To perform Visual and Magnetic Particle Inspection on:


1. 1.625” -8 UN x 3/4" -10 UN, Bonnet, Pressure Relief Tool

 Job No.: 15MMM1766C


 SN: 15MMM1766C
 PN: 13985-02 Rev. 0
 H.T.: 140070

Procedure: Acceptance Criteria: Equipment: Magnetic Lift Load


API RP7-G-2 (ASNT API RP7-G-2 (ASNT DC Coil(1123072C) / -
Level III Approved) Level III Approved)
Material: B. Inten. (µW/cm²): Light Dist. (inches): P. Con.(ml/100ml):
4140 80KSI 2130 (1859254/5) 15 0.3
Background: Particle: Technique: Field Adequacy and
Direction:
Natural Fluorescent Particle Longitudinal / Indirect Magnetic Particle Field
(20B Batch#: 15D074) Method Indicator
Results:
At the time of inspection, no relevant indications were found and all areas inspected were acceptable to code.

Inspected by: _______________________


Mr. Ancil Owen
SNT-TC-IA Level II
Doc. Ref. - ROSL/017
Rapid Oilfield Services Limited
#51 Market Steet, Gopaul Lands, Marabella, Trinidad, W.I.
Tel./Fax: (868) 221-2643 Cell: (868) 682-2911/384-5571
e-mail: admin@rapidoilfield.com

Magnetic Particle Inspection Report

Client: IAL/ IAL/ Massy Energy Engineered Attention: Mr. H. Singh


Solution Ltd

Project: Body Pressure Relief Tool Date (dd/mm/yyyy): 18/01/2016

Job Location: IAL Facility, San Fernando Inspection Date (dd/mm/yyyy): 18/01/2016

Ticket No.:

Job No.: 16-0069 Report No.: IA10723

Job Description:

To perform Visual and Magnetic Particle Inspection on:


1. 3/4” LP Pin x 1.625” -8 UN x 1/2” LP Port , Body Pressure Relief Tool

 Job No.: 15MMM1766B


 SN: 15MMM1766B
 PN: 13985 Rev. 0
 H.T.: 140070

Procedure: Acceptance Criteria: Equipment: Magnetic Lift Load


API RP7-G-2 (ASNT API RP7-G-2 (ASNT DC Coil(1123072C) / -
Level III Approved) Level III Approved)
Material: B. Inten. (µW/cm²): Light Dist. (inches): P. Con.(ml/100ml):
4140 80 KSI 2130 (1859254/5) 15 0.3
Background: Particle: Technique: Field Adequacy and
Direction:
Natural Fluorescent Particle Longitudinal / Indirect Magnetic Particle Field
(20B Batch#: 15D074) Method Indicator
Results:
At the time of inspection, no relevant indications were found and all areas inspected were acceptable to code.

Inspected by: _______________________


Mr. Ancil Owen
SNT-TC-IA Level II
Doc. Ref. - ROSL/017