LEGEND

GENERAL NOTES: CHANDELIER Sa / S SINGLE POLE SWITCH


1-40w FLUORESCENT LAMP S2bc / S2 2-GANG SWITCH
1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH ELECTRICAL SERVICE ENTRANCE
LIGHTING FIXTURE
THESE PLANS AND SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATEST
EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE RULES AND REGULATIONS OF THE M KWHM KILOWATT-HOUR METER
LOCAL ENFORCING AUTHORITY, AND THE REQUIREMENTS OF THE LOCAL POWER. THE 01
PP BRANCH CIRCUIT HOMERUN ACU OUTLET
ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED
ELECTRICAL ENGINEER. DUPLEX CONVENIENCE OUTLET LIGHTING LINE, CONCEALED ON CLNG.
2. THE ELECTRIC SERVICE VOLTAGE SHALL BE SINGLE PHASE 3-WIRE WITH GROUND 230V 60HZ. E.RANGE OUTLET POWER LN., EMBEDDED ON SLAB/WALL
3. THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN INTERMEDIATE METALLIC CONDUIT (IMC) REFRIGERATOR OUTLET TELEPHONE OUTLET
ELECTRICAL METALLIC CONDUIT (EMT). FLEXIBLE METALLIC CONDUITS SHALL ALSO BE USED
WHERE REQUIRED. MINIMUM SIZE FOR ALL CONDUITS SHALL BE 15mm INSIDE DIAMETER
WEATHERPROOF OUTLET CABLE TV OUTLET
ELECTRICAL TRADE SIZE MINIMUM SIZE OF PULLBOX TO BE USED SHALL BE 150x150x100mm. ABOVE COUNTER OUTLET PP,LP,PB PANEL BOARD
4. ALL WIRES FOR INDOOR INSTALLATION SHALL BE
COPPER AND THERMOPLASTIC INSULATED TYPE THWN/THHN UNLESS OTHERWISE INDICATED. THE

5. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF INCOMING POWER
FOR CONNECTION INCLUDING THE LOCATION OF METER CENTER.
6. ALL PIPE SLEEVES SHALL BE PROVIDED WITH PROPER SUPPORT OR ANCHORAGE NECESSARY
FOR PERMANENT CONNECTION WITH CONCRETE WALLING OR BEAM.
7. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND ALL
NON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED IN ACCORDANCE
WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.
8. ALL 20-AMPERE CIRCUIT HOMERUNS TO PANELBOARDS OF MORE THAN 30 METERS IN
2
LENGTH SHALL BE 5.5mm UNLESS OTHERWISE SPECIFIED

PANEL
9. CONDUIT ROUTING SHOWN IS ESSENTIALLY DIAGRAMMATICAL. CONTRACTOR SHALL LAY OUT RUNS
TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF UTILITIES & OTHER TRADES.
10. ANY DISCREPANCY IN LOCATION AND RATINGS OF EQUIPMENT AND APPARATUS SHALL BE
VERIFIED WITH THE ENGINEER/OWNER OR ANY OF HIS REPRESENTATIVES AND CHANGES
S1 S1
SHALL BE MADE ACCORDINGLY. S2

11. ALL MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED SHALL BE NEW AND MUST
BE OF THE APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE INTENDED.
12. ALL CONDUITS AND RACEWAY PENETRATIONS THROUGH FIRE OR SMOKE RATED WALLS AND FLOORS
SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAME AND HOT
GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC OF FIRE STOPS S2
S2
ASTM-E-814. PROVIDE A UL LISTED THROUGH PENETRATION FIRE STOP SYSTEM NUMBERED PER UL
FIRE RESISTANCE DIRECTORY.
13. MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS:
SWITCHES : 1,370MM ABOVE FLOOR FINISH
150
RECEPTACLES : 300MM ABOVE FLOOR FINISH
: 170MM ABOVE COUNTER TOP
PANEL BOARD : 1800MM ABOVE FLOOR FINISH
1 POWER & AUXILIARY LAYOUT
E-1 SCALE: 1:100 MTS.

PROJECT & LOCATION OWNER SHEET CONTENTS SHT NUMBER


ALL PLANS AND SPECIFICATIONS, AS INSTRUMENTS
OF SERVICE, ARE THE PROPERTY OF THE DESIGNER GENERAL NOTES
AND CANNOT BE COPIED OR DUPLICATED IN PART OR
ENGINEER
JUAN DE LA CRUZ POWER & AUXILIARY LAYOUT

DESIGNER
IN WHOLE WITHOUT WRITTEN PERMISSION,THIS MUST
HAVE TO BE RETURNED WHEN NO LONGER IN USE. REG. NO : PTR. NO : E-101
TIN NO : DATE : DRAWN: JBS 08/07/13