I SUNYEH) QUARTER-TURNELECTRIC ACTUATOR

Power Torque Speed Weight Manual MountingFlange


Model No.
(Watts) (Nm) (Sec/90n) (ke) Override (ISOs2lr )
BM.2 40w 120 8 4.5 N/A F07
OM.A 10w 50 20 3.0 N/A F07
oM-l 10w 35 t2 2.0 Lever F05/F03
oM-2 40w 90 l5 I1.0 Hand-wheel F07
oM-3 40w 150 22 11.0 Hand-wheel F07
oM-4 120W 400 16 22.0 Hand-wheel Fl0
oM-5 120W s00 22 22.0 Hand-wheel F10
oM-6 120W 650 28 22.0 Hand-wheel Fl0
oM-7 180W 1000 46 36.0 Hand-wheel FI4IF12
oM-8 220W I 500 46 36.0 Hand-wheel F14tFt2
oM-9 180W 2000 58 s6.0 Hand-wheel F16IF14
oM-10 220W 2500 s8 56.0 Hand-wheel F16/Ft4
oM-l1 250W 3000 58 s6.0 Hand-wheel Ft6/F14
oM-12 300w 3500 58 56.0 Hand-wheel Fr6/Fl4

'13
1rl
SUN YEH

I SUNYBHI QUAR TER-TURNELECTRIC ACTUATOR

FEATURES
o Enclosure:
O lP 67 : Waterproof and dust-proof enclosures.
O NEMA 4X : Waterproof and dust-proof enclosures.
@ Material: Dry powder coating aluminum alloy.
o Motor:
O Standardextended duty cycle induction motor. H insulation class for
OM- I and OM-A; F class for BM-Z, and O}d-z to OM- 12.
@ Built-in thermal protection (135"C) prevents motor burning out.
o Position Indicator:
@ All models have continuous mechanism position indicator on the top of
actuator cover.
o Manual Override:
O Non-clutch design, the manual operation can be operated without any lever,
clutch or brake upon power outage.
@ When electric motor is operating, manual hand-wheel won't rotate for person
safe purpose.
o Gear Tbain:
@ High alloy steel gear trains provide self-locking function to avoid valve back
drive.
o Gear trains have been already lubricated sufficiently with anti-high
temperature lubricant at the factory.
o Working Conditions:
O Ambient temperature:-5oC - +60oC.
O The humidity: 30Vo- 957o.
o Various Options:
@ Space heater.
o Additional limit switches (2 units).
O Potentiometer unit (lK Ohm).
O Local control unit (locaVremote, on/off).
@ Conduit entrance(112" W,314" PF, ll2" NPT).
O Adjustable torque switches (2 units).
O Current position transmitter (output 4-20mA).
O Modulatingcontroller.
O Various voltages.
O Nylon enclosure material.
o Certificates:
@ ISO 9001.
@ CE.
O CSA. (Conforming to the test standard of outdoor usage.)

14
QUARTER-TURNELECTRIC AC TUATOR

DIMENSIONS

Unit:mm
Direrciqrr_ n
Flange
Model NO.
'1 B C D E F G H N S Type
Max
1/2
BM-2 r154 160 22 192 30 70 30.1 mB 4 1 PT F07

1.. E

*Option:
J = 1 4, F = 1 9
*
With modulatingsspflP=233 Unit:mm
__ Dimerqigr B ic D E F H l S
Jh"g"
- MqdNe l- o - , , - - A ; . .
l . Tyle
oM-A 1/2
108 I r oo 45" 20s 16 24 * A 4 ' FCI7

15
{f
QUARTER-TURN ELE CTRIC ACTUATOR

DIMENSIONS

*
O p t i o n : ( 1 ) L =,1M1= 1 5 ( 2 ) L = 9 , M = 1 2 W i t hm o d u l a t i ncga r dD = 1 8 5
Unit:mm
rtanse
l l

H i l i J K L]tiNit I
ModelNO. " ] ' ; ' , o ---*---*--l-** .* *--,i"*"***.._ l n q l l - - .-, i - t lYps--
1 4i r n i r l y +| r o o r r o s
i l
oM-1 155i tSl
36 i m5:
4 i m 6 i 6 50

'16
dr|
QUARTER-TURN ELECTRIC ACTUATOR

DIMENSIONS

Unit:mm
Dimension Flange
ModelNo.--
A B c D E F G
Max
H I M N S
Type
1/2
OM-4-OM-6 300 380 234 315 40 195 35 102 m10 4 11
Z P T F10

* Note:without
torqueswitch4=385
Dimension I i i-l-
t o E l r
1 l_' l I i - - H - - r - l c i H; ' i
___ueq"_rr.6. i
t l J K lL i M
: [g
oM-z-oM-B
];;i*!g41420 I 60i2951144
0 5 m 1 6 4 i 1 8 01 1 0 35

17
QUARTER-TURNELECTRIC ACTUATOR

DIMENSIONS

Unit:mm
Dimension-
MoOet-wO.
A i B c D F G ] * J K L M P N S Flange
i_ I Tvpe
I
oM-g-oM-12 470 I 350 260 ue; 395 ,r'-l ;; m20 4 75 1 6 5 zzrl g; 2 1/2 F 1 6 / F 1 4
PT

Unit:mm

A j t C D E F G H I M i N s i tj"ng"
.od -
t",1 I ype

--l_
E*- 275 350 i
i---

- . ' - . r-
30 I 125
i
22 70 4 m 8 2
lf-i -t-o'
I i-'-
455 305 310 410 40 . 195 35 102 4 m10i 2 y+ F1o

18
ELECTRICACTUATOR
ISUX YEH ) QUARTER.TURN

OPTION ITEMS

TORQUE SWITCHES POTENTIOMETER UI.{IT


OM-I&OM-A Ali4-2*12
( l K Q o r 5 K Q) ( lKQor 5KQ)

Adjustable cam activatedtorque switchesto provide


N.N
It is synchronousturn with transmissionshaft, and it can
over-load protection. provide feedbacksignal for position indicator and etc.

LOCAL CONTROL UNIT MODULATING CONTROLLER FOR O}.f'2r.12

Modulating actuator : 307o or 757c duty cycle for OM-2-8 ,


507oduty cycle for OM-9- 12.
It is a board inside actuator and supplied for OM-2 -12.
Local / Remoteselectionswitches.Open / Close lnputsignal:4-20rnA,l-5V 2- tOV.Outputsignal:
selectionswitches. 4-20rnA,2-l0V.

CURRENT POSITION TRANSMITTER MODULATING CONTROLLER FOR OM.I.OM-A

It is a boardinsideactuatorandsuppliedfor OM- I &


It u,orks with potentionreterunit and provides 4-20mA OM-A. Inputsignal:4-20mA,l-5V , 2-l0V " Output
output signalfor positionindicatorand etc. 4-20mA,2-I0V.
signal:

19
lrf
ELECTRICACTUAToR
ISUX YEH ) QUARTER-TURN

OPTION ITEMS

HEATER TRAVEL CAMS & LIMIT SWITCHES

Additional
: N

DC/ACZ4V 22OV t t0v


Standard
A spaceheaterkeepsthe componentpartsof the
actuatordry and preventsthe condensationfor low
temperature
and humidity.

VARIOUS VALVES

20
. WIRINGDIAGRAM

[OM-l & OM-A ll0Vl220VAC l-PH 30"h du$ cycle)

Note: When a set of controlwire needsto controltwo or more actuatorsat the sametime,
pleasereferP.62.

Power Note:
tr0t220v (1). "N" connects to 1.
1-phase (2)."L" connects to 3 for "OPEN".
(3). "L" connectsto 4 for "CLOSE".
(4). LS -- Limit switch.
(5). Using lessthan 3A currentfor switches
"A,B,C,E,F".
(6). "L" connectsto 7 for heater.(option)
a a

/- -g -l cJ

o 6'

t- -
o.L 3

rP
tn

i
at
(option) (option)

II ACTUATOR
I

21
. WIRINGDIAGRAM

(BM-2, OM-2^OM-12 ll0vl220VAC l-PH 30"h duty cyctel


Note: When a set of control wire needsto control two or more actuatorsat the sametime,

pleaserefer P.62.

Power
I t0l220v Note:
I -phase ( I ). "N" connects to 1.
( 2 ) . " L " c o n n e c ttso 3 f o r " O P E N " .
EI (3). "L" connects
(4).LS -- Limit switch.
to 4 for "CLOSE".

-I (5). Usinglessthan3A currentfor switches


"A,B,C,E,F".
(6) "L" connects to 7 for heater.(option)
v Yl
-
I C S
r-A-_l
()
r t l (D (t
o
L I- -Y_J
() C)

-1
-
otl- -
J

r-l+
l : -

IT
(option) (option)
-l
|rl

r5

ACTUATOR