PROJECT: HOCKEY STADIUM AT HYDERABAD DOCUMENT NO. DATE
TITLE: CRACK WIDTH CALCULATION FOR WALLS DESIGNED CHECKED SHEET
PHK SSM
CHECK FOR CRACK WIDTH : as per IS 456 : 2000 ANNEX F
GRADE OF CONCRETE fck = 30 N/mm2
MOMENT AT THE SECTION CONSIDERED M = 1.5 tm
DEPTH OF THE SECTION D = 450 mm
DEPTH OF THE FLANGE Df = 150 mm
EFFECTIVE DEPTH d = 407.5 mm
BREADTH OF THE FLANGE Bf = 1000 mm
COVER TO THE COMPRESSION STEEL d' = 54.5 mm
DISTANCE FROM THE POINT CONSIDERED TO THE SURFACE OF THE NEAREST acr = 92.7 mm LONGITUDINAL BAR
MINIMUM COVER TO THE LONGITUDINAL BAR Cmin = 54.5 mm
THE WIDTH OF THE SECTION AT THE bt = 1000 mm
CENTROID OF THE TENSION STEEL
MODULAR RATIO m = Es/Ec 8
AREA OF TENSION STEEL Ast = 400 mm2
AREA OF COMPRESSION STEEL Asc = 0 mm2
NEUTRAL AXIS x = 47.97 mm
CRACKED MOMENT OF INERTIA Icr = 4.50E+08 b
SERVICE STRESS IN TENSION fs = m x M x(d-x)/Icr 93.96 N/mm2 REINFORCEMENT MODULUS OF ELASTICITY OF STEEL Es = 2.00E+05 N/mm2 DISTANCE FROM THE COMPRESSION FACE TO THE POINT AT WHICH THE CRACK WIDTH a' = 150 mm IS BEING CALCULATED STRAIN AT THE LEVEL CONSIDERED, e1 = ((D-x)/(d-x)) x fs/Es 0.000525
em = e1- (bt(d-x)(a'-x) ) 0.000405 ###
3EsAst(D-x)
DESIGN SURFACE CRACK WIDTH Wcr = 3 x acr x em 0.09 mm