LARSEN & TOUBRO LIMITED

ECC Division – EDRC

PROJECT: SRI SREENIVASA SPORTS COMPLEX AT DOCUMENT NO.


TIRUPATI
TITLE : INDOOR STADIUM - CALCULATION FOR DEVELOPMENT DESIGNED CHECKED
LENGTH

DEVELOPMENT LENGTH = F ss / (4 tbd)

F = Nominal diameter of bar.


ss = Stress in the bar at the section considered at design load.
tbd = Design bond stress.
Design Bond stress for M20 Grade = 1.2 N/mm2 Refer IS-456.

For Deformed bars, the bond stress shall be increased by 60%.

For bars in compression, the bond stress shall be increased by 25%.

Hence, bond stress for deformed bars in compression = 1.6*1.25*1.2 = 2.4 N/mm2

Hence, bond stress for deformed bars in tension = 1.6*1.2*1.33 = 2.5536 N/mm2

ss = 0.87*sy = 361.05 N/mm2

Development length in compression (Ldc) = F * 361.05 / (4 * 2.4)


Ldc = 37.61 F

Development length in tension (Ldt)= F * 361.05 / (4 * 2.66)

Ldt = 35.35 F

All Dimentions are in mm.

Column. Type. FOT. Type Max bar F Ldc Reqd. Ldt Reqd. Ld Provided.

C1 F1 20 752 707 780


C3, C4 & C5 F2 16 602 566 580

C12 & C12A F3 20 752 707 900

C13, C14 F4 20 752 707 950


C2 F5 12 451 424 850

C6 & C7 F6 16 602 566 850

C8, C9, C10 & C11 F7 25 940 884 1000

C15 F8 20 752 707 850

C16 F9 12 451 424 430


DATE
10.08.2002
PAGE

33% Stress is
increased for
Seismic load.
LARSEN & TOUBRO LIMITED
ECC Division – EDRC

PROJECT: DOCUMENT NO.

TITLE : DESIGNED CHECKED

DEVELOPMENT LENGTH = F ss / (4 tbd)

F = Nominal diameter of bar.


ss = Stress in the bar at the section considered at design load.
tbd = Design bond stress.
Design Bond stress for M20 Grade = 1.7 N/mm2 Refer IS-456.

For Deformed bars, the bond stress shall be increased by 60%.

For bars in compression, the bond stress shall be increased by 25%.

Hence, bond stress for deformed bars in compression = 1.6*1.25*1.7 = 3.4 N/mm2

Hence, bond stress for deformed bars in tension = 1.6*1.7*1.33 = 3.6176 N/mm2

ss = 0.87*sy = 361.05 N/mm2

Development length in compression (Ldc) = F * 361.05 / 4 * 3.4


Ldc = 26.55 F

Development length in tension (Ldt)= F * 361.05 / 4 * 3.6176


Ldt = 24.95 F

Diameter of Bar Ldc Ldt Ld Provided

20 531 499 780


25 664 624 1000 Hence O.K

Maximum Stress in Steel is considered for arriving at the development length.


However actual stresses will be much less.
DATE
10.08.2002
PAGE

33% Stress is
increased for
Seismic load.