You are on page 1of 3

Show facsimile of manufacturer's logo or trademark, as it will

TECHNICAL STANDARDS & appear on the fitting, in the space below


SAFETY AUTHORITY 'I

J
14th Floor, Centre Tower
3300 Bloor Street West
Toronto, Ontario
Canada M8X 2X4 OR ···/ICiAULie'

STATUTORY JjJ~,~.~~...~.Ll•. IL.... ~


Registration of Fittings
I WILLIAM D'AMICO- DIRECTOR, GLOBAL EH&S I QUALITY ASSURANCE
'------------------------~--~~~--~~~~--~--~~~~~----------------------
(Name and Position, e.g. President, Plant Manager, Cllief Engineer)

f VICTAULIC
0 ----------------------------~~~~~~------------------------------
(Name of Manufacturer)

Located at 4901 KESSLERSVILLE ROAD, EASTON, PA. 18040-6714, USA 610-559-3389 61 0-923-3986
(Plant Address) (Telephone No.) (Fax No.)

0 do solemnly declare that the fittings listed hereunder, which are subject to the Technical Standards and Safety Act, Boilers
and Pressure Vessels Regulation, comply with all of the requirements of

(Title of recognized North American Standard}


which specifies the dimensions, malerials of construction, pressure/temperature ratings, identification marking the litlings and service;

[ZJ or are not covered bv the orovisions of a recognized North American standard and are therefore manufactured to comply with
...... ANS.I B31.1 * & A.~§J.£1? ~-·-~~.:.. __ as supported by the attached data which identifies the dimensions, malerial of construction,
pressure/temperature ratings and the basis for such ratings, the marking of the fitting for identification and service.

I further declare that the manufacture of these fittings is controlled by a quality system meeting the requirements of ISO 9001
_ _ _ _ _ _ _ which has been verified by the following authority, LPCB=----------------'
The items covered by this declaration, for which I seek registration, are category 'A' type fittings. In support r:J
this application, the foUowinQ information and/or test data are attached as follows:
Technical Sheet TS-226-A-05-15, Proof Test Results & Product Submittals
(drawings, calculations, last reports, etc.)

------------------------- in the -----~~--------- of


EASTON STATE PENNSYLVANIA

the best of my knowledge and belief, the application meets the requirements
'---+ill!c~n/ca/ Standards and Safety Act, Boilers and Pressure Vessels R~ulation,
CSA Standard 851 and is accepted for registration in Gategory ----L->~----t-·

CRN: 23.S":frD'DI
Registered by:

Datecl: t?clt-be4 41 2o{d-


This g
PV 09553 (06104)
• ANSI B31.1 - Mechanical Joint (Paragraph I 00.2) & Other Proprietary Joints (Paragraph 118)
**ANSI 831.3- Mechanical Joint (Paragraph 300.2) & Special Joints (Paragraph 318 & K318)

!. Ad~.k0r. cJ 2J s+y/€ 81--o ~· ~


:Z.. se.e_ a}ja._ChJ Sfctmted sare ¥ ~~~bH.9H _/L-
~- ·.

tauliC!O
TECHNICAL SHEET TS-226-A-05-15 -------:·
<.:..___.. v•

Piping Systems Coming Under tlte Jurisdiction of


Provincial Boilers and Pressure Vessels Act
Revised: 10/22/15 .Page 1 of 1
. CATEGORY 'A'
Coupl~ngs registered in accordance with CSA-B51 - Category A
1 Couplings comply with ASME B31.1 & B31.3
I
··-·----······ i'
Brodmre No. I Working Pressure PSI
Grooving Test
Product Reference
Dimensions
Material Sp.cification
II
Specification
Size
Number
Under Pressure Piping
Codes B31.1 & B31.3
Service
I
! 2"- 6" 740 psi I 5,102 kPa*'1 Non-Steam Service,,:~ I
I 8" 635 psi I 4,378 kPa*'1 I to wooF! 38oc I
Housings: Du?tile lron to ----·············-··"'"""'''"""-'''¥"''''''''''''''''"--········-----···--·-·-·--·---1
ASTM A536, Glade 65-45-12 2"- 6" 1001, 1004 648 psi I 4,468 kPa* 4 Non-Steam Service ~·~
Sty!e 870
VS-100.02 Bolts: ASTM A 93, Grade B7 VS-25.12
Rigid Coupling 8" & 1036 635 psi I 4,378 kPa* 4 to 366°F I 186°C
Nuts: ASTM A194, Grade 2H
Washers: ASTM! F436, Type 3 Saturated Steam
'' 2"- 8" 150 psi I !,034 kPa':' 4 Service* 3 to 366°F I

····- ................-----·---·· ···-· - I I -··-·--·..-···-··-·-·-····-·····--·---····


186°C
········-··

•::i - Non-steam applications with pressure~ ranging from fu!l vacuum (29.9" Ffg I 760 mm Hg) up to the Maximum Allowable Working
Pressure shown at 100°F I 3 8°C :
I
!
':' 2 .. Non-steam applications with pressure~ ranging from full vacuum (29.9" Hg I 760 mm Hg) up to the Maximum Allowable Working
Pressure shown at 366°F I 186°C

'1'3 - Saturated steam applications rated up to 150 psi /1,034 kPa at 366°F /186°C. This product is not suitable :for use in superheated
steam applications.
!

:::-+-Maximum Allowable Working Press~~·e when used on schedule 40 or 80 carbon steel pipe conforming to ASTM A53, Grade B,
ASTM A106, Grade B, or API 5L, Grade B, and fittings conforming to ASTM A234, Grade WPB or ASTM A lOS.

123 Newkirk Road; Richmond Hill, Ontario L4C 3G5 Tel.: 905-884-7444 Fax: 905-884-7446
~taulic·
VICTAULIC MANUFACTURING LOCATIONS
& CERTIFYING AUTHORITIES
(rev. August 20, 2015)
Victaulic Company of Canada Limited
123 Newkirk Road
Richmond Hill, ON
L4C 3G5
ISO 9001 Certified by QMI-SAI Canada Limited

Victaulic Company
4901 Kesslersville Road
Easton, Pennsylvania, USA, 18040
ISO 9001 Certified by LPCB

Victaulic Company
8023 Quarry Road
D/
Alburtis, Pennsylvania, USA, 18011
ISO 9001 Certified by LPCB

Victaulic Company
2010 Enterprise Drive NE
Leland, North Carolina, USA, 28451
ISO 9001 Certified by LPCB

Victaulic Polska Sp. zo.o.


UI. Niepodleglosci 8
PL-66-530 Drezdenko, Poland
ISO 9001 Certified by VdS Schadenverhutung

Victaulic Piping Products (Dalian) Co., Ltd


No. 13 Tieshan Dong 2 Road
Dahan Development Area
Dalian, Liaoning, China, 116630
ISO 9001 Certified by BSI Management Systems (China)

Dalian Bingshan Metal Technology Co., Ltd


No. 9, Northeastern 1 11 Street
Huaihe Western Road
Economic and Teclmology Development Zone
Dahan, Liaoning, China, 116600
ISO 9001 Certified by BSI Management Systems (China)