You are on page 1of 5

Te s t i n g R e p o r t

Product Name GFX300 OPzS Acid-proof Stationary Battery

Manufactured by Jiangsu Shuangdeng Group Co.,Ltd

Test Category Type Test

April 3,2009
Jiangsu Shuangdeng Group
OPzS Acid-proof Stationary Battery
Testing Report

OPzS Acid-proof Stationary


Product Name Model GFX-300
Battery

Manufactured Test Category Type test


Jiangsu Fuste Testing Laboratory
by Sample date Aug 8,2008

Samples
Sample quantity 9 pcs Technology Dept.
sent by

Testing Items 7 Code 1# ~9#

IEC60896-11: 《Stationary lead-acid batteries-part 11:Vented types-General


Product Name
requirements and methods of tests》
GFX-300 OPzS Acid-proof Stationary Battery testing items:
1. Appearance
2. Structure
3. Capacity (C10、C5、C3、C1、C0.5)
4. Floating application testing
5. Charge maintaining ability
6. Short circuit current
7. Cyclic testing
Conclusions

Above 7 items testing all reach standards of IEC60896-11: 《Stationary

lead-acid batteries-part 11:Vented types-General requirements and methods of tests》

Executive:于士勇/2009.4.3 Approval:周刚/2009.4.3
Jiangsu Shuangdeng Group
OPzS Acid-proof Stationary Battery
Testing Report

Manufactured by:Jiangsu Fuste Power Supply CO.Ltd Model:GFX-300 Quantity:9Pcs


Battery
Number Testing Items Unit Standard Requirement Testing Result Conclusions
Code
Smudginess No smudginess No smudginess Passed
1 Appearance — 1# ~ 9#
Deformation Not deformative Non-deformative Passed
Crack Not with cracks Not with cracks Passed
# #
2 Structure Polarity — Obvious polar signs 1 ~9 Yes Passed
Discharge at 30A with
Discharge at C10 Ah end voltage 1#~9# ≥325.0 Passed
1.80V≥300Ah
Discharge at 51A with
Discharge at C5 Ah end voltage 1#~9# ≥266.3 Passed
1.80V≥255Ah
Discharge at 75A with
3 Discharge at C3 Ah end voltage 1#~9# ≥235.0 Passed
1.80V≥225Ah
Discharge at 150A
Discharge at C1 Ah with end voltage 1#~9# ≥155.9 Passed
1.75V≥150Ah
Discharge at 229.5A
Discharge at C0.5 Ah with end voltage 1.70V 1#~9# ≥118.0 Passed
≥114Ah
Charge with constant
voltage 2.23V/cell, and
6 months later,
Floating application
4 — C10≥norminal 1#~6# 330.0 Passed
testing
capacity , and other
battery indexes are
stable

Afte r 90 days kept, the


5 Charge maintaining ability % 7# 88.8% Passed
rest of capacity ≥85%
1. Discharge at
5I10A for 20S,
then record
voltage and
short circuit
current; with 5 For
Short circuit current current:3661A
min. interval , customer’s
6 A 8# Internal
measure it reference
resistance:
2. Discharge only
0.53mΩ
at20I10A for
5S , record
voltage and
current
Discharge at 2I10 for
3h,then charge with
2.4V/cell,limited
current2I10 for 21h,
7 Cyclic testing % then repeat above. Test 9# 105.5% Passed
C10 each other
50cycles. When at 100
cycles, norminal
capacity≥95%

Executive:于士勇/2009.4.3 Approval:周刚/2009.4.3
Jiangsu Shuangdeng Group
Testing Equipment and Instruments
For Stationary lead-acid battery

Number Equipment and Model Specifications Remarks

Instrument

1 Discharging Machine RCT600-1-12V 12V ×600A Discharging

2 Discharging Machine RCT2600-1-2V 2V ×2600A Discharging

Cyclic Charging and Charging and


3 μC-XCF 12V ×100A
Discharge Machine 1 discharging

Cyclic Charging and Charging and


4 μC-XCF 12V ×100A
Discharge Machine 2 discharging

5 DC Power YJ90 60V×10A Floating charge

6 Digital Multimeter MS8218 Voltage

measuring

Testing conditions:

Room temperature:(24~27)℃

Humidity:70%

You might also like