CONTENTS

Volume I Page

Preambles P-1 to P-29

Fixed Schedule of Rates

Piling A1 – A7

Excavation B1 – B10

Concrete Work C1 – C22

Brickwork & Blockwork D1 – D9

Roofing E1 – E29

Carpentry & Joinery F1 – F56

Ironmongery G1 – G14

Structural Steelwork H1 – H5

Metal Work I1 – I22

Wall & Ceiling Finishings J1 – J8

Floor Finishings K1 – K1 2

Plumbing L1 – L71

Glazing M1 – M10

Painting & Decorating N1 – N18

External Works P1 – P29

Miscellaneous Q1 – Q6

Additional Items R1 – R6

P-1
PREAMBLES

1.1 GENERAL

1.1.1 The Fixed Schedule of Rates shall form the basis for valuing all
variations. It is to be read in conjunction with other Contract
Documents and the relevant Preambles in these Sections

1.2 MEASUREMENT AND QUANTITIES

1.2.1 Unless otherwise specified in this Fixed Schedule of Rates, all


measurement shall be based on the Standard Method of
Measurement of Building Works (Second Edition) published by
the Singapore Institute of Surveyors and Valuers. In the event of
any discrepancies between the Standard Method of
Measurement of Building Works and this Fixed Schedule of
Rates, the latter shall take precedence.

The following units of measurement shall be adopted throughout


the Fixed Schedule of Rates unless otherwise provided:

i. Items given by cube (volume) - cubic metre (m3)


ii. Items given by super (area) - square metre (m2)
iii.Items given by run (length) - linear metre (m)
iv. Items enumerated - number (No)
v. Items given by weight - kilogramme (kg)
- tonne (t)
vi. Items given by time - man hour (hour)

1.2.2 Dimensions used in calculating quantities shall be taken to the


nearest 10mm (i.e. 5mm and over shall be regarded as 10mm
and less than 5mm shall be disregarded). This rule shall not
apply to any dimensions stated in the discrepancies.

1.2.3 Quantities measured in tonnes and quantities less than half a unit
shall be given to two places of decimals. Other quantities shall be
given to the nearest whole unit (i.e. 0.5 and over shall be
regarded as 1).

1.2.4 Words in the singular shall include the plural and words in the
plural shall include the singular according to the context. Words
importing the masculine gender shall include the feminine or
neuter as the case may require.

1.3 DESCRIPTIONS AND RATES

1.3.1 Dimensions stated in item descriptions are generally in the


sequence of length, width and height.
1.0 GENERAL (CONT’D)

1.2 DESCRIPTIONS AND RATES (CONT’D)

1.3.2 Headings to groups of items shall be read as part of the


descriptions of the items to which the headings apply.

1.3.3 The descriptions and rates in this document are applicable to


work on or in a new or existing building including working outside
the building but within the Site.

1.3.4 Horizontal surfaces stated in the item descriptions found in this


document refer to sloping surfaces not exceeding 15º from the
horizontal.

1.3.5 Unless otherwise stated, the terms “as specified” means as


specified in any of the documents forming part of the Contract.

1.3.6 Where an item is described as “Add to (or deduct from) .... For
each 5mm thickness over (or under) .....”, the difference for any
thickness less than 5mm shall be paid/deducted based on 5mm
thick

1.3.7 Where an item is described as “Add to the last item for the
increase in stages of 150mm deep”, the difference of any depth
less than 150mm shall be paid on 150mm depth.

1.3.8 Unless otherwise stated, rates in the Fixed Schedule of Rates are
applicable to works at horizontal surfaces exceeding 300mm
wide.

1.3.9 The rates for skirtings shall be applicable to the following :

a) drops, risers, sides of plinths and kerbs and other vertical


surfaces not exceeding 300mm high

b) treads, top of kerbs and other horizontal surfaces not


exceeding 300mm wide.

P-3
1.0 GENERAL (CONT’D)

1.2 DESCRIPTIONS AND RATES (CONT’D)

1.3.10 The Fixed Schedule of Rates shall be deemed to include for all
cost in connection therewith including equipment, storage, tools,
plant, labour in unloading, transferring, setting, hoisting, fitting of
materials and goods in position, including materials required for
lapping, jointing and the like, preparing surfaces to receive new
f inishes and all costs in connection therewith such as
conveyancing, duties and taxes, delivering, unloading, storing,
returning packings, handling, hoisting and lowering; for all
cutting and waste of materials; for all incidental materials such as
nails, screws, spikes, plugs, putty, tow, solder, etc. whether or
not specifically mentioned in the Fixed Schedule of Rates;
cleaning up on completion and making good all work disturbed,
for all establishment costs, overheads and profit; compliance with
laws, regulations and government departments‟ requirements,
access such as staging, professional engineer’s certification
for safe access.

1.3.11 The Fixed Schedule of Rates shall be deemed to have included


for all costs in respect of all time delays caused by workmen as
applicable, for annual and public holidays, rest days, traveling
time, expenses, fares and transport, government levies, non-
productive time and other incentive and bonus payments, and
any other costs or disbursement arising from employment of
labour.

1.3.12 Unless otherwise stated, all items in the Schedule of Rates


specifying materials, fittings etc. are to be read as implying that
such materials, fittings are to be provided and fixed by the
Contractor.

1.3.13 In the event that special scaffolding, machinery and equipment


are required just to execute the variation work, these shall be
paid separately.

1.4 ALTERATIONS

1.4.1 Rates

1.3.1.1 Rates for alteration work shall be held to include for:

(a) executing the work in such a way as to ensure the


safety of, and cause as little inconvenience as
possible to, adjoining properties and occupants, the
public in general, passing vehicles and workmen

P-3
1.0 GENERAL (CONT’D)

1.3 ALTERATIONS (CONT’D)

1.3.1 Rates (Cont’d)

1.3.1.1 Rates for alteration work shall be held to include for:


(Cont’d)
(b) wedging and pinning up, cutting to line remaining
portions, making good any component which
c ol lapse s o r is pu l le d do wn i n exc e ss of
requirements, and preparing surfaces of floors under,
ceiling over, and abutting surfaces of columns or side
walls to receive new finishes, facing up or flushing up
existing surfaces after cutting to match the
surrounding work and cutting back old plaster and
pavings etc for joints with new
(c) removing all old materials, debris etc off Site including
paying all dumping fees, charges etc

(d) covering up and protecting the Works from damage


by dust, sun, rain and similar hazards and protecting
the occupants and the general public from dust
nuisance, falling rubbish and the like

(e) all other work necessary or implied to complete the


alterations work in a proper and workmanlike manner
in accordance with the Contract Documents and
Drawings

1.3.2 Terms

1.3.2.1 The term "removing" shall mean disconnecting,


dismantling, getting out and removing from the Site of
the component to which it refers, complete with all
associated battens, grounds, brackets, fixings and
supports etc

1.3.2.2 The term "preparing to receive new finish" means raking


out joints of existing brickwork or hacking surfaces of
existing concrete, thoroughly cleaning down and
watering as necessary and appropriate to receive new
finish, including spatter dashing or washing over with
cement grout if ordered by the Superintending Officer.

1.3.2.3 All patches and repairs to internal plaster and external


plaster are measured nett as required to be completed

P-4
1.0 GENERAL (CONT’D)

1.3 ALTERATIONS (CONT’D)

1.3.2 Terms (Cont’d)

1.3.2.4 No provision is made for large or small quantities, narrow


widths, easy or difficult locations or any other exceptional
circumstances

1.3.2.5 Rates for cutting into and taking down concrete or


brickwork etc including cutting chases, sinkings, grooves,
holes and similar items shall be held to include for
removal of debris. All material arising from these
operations shall become the property of the Contractor

1.3.2.6 Rates for demolition of brick or concrete walls shall be


held to include all finishings and dadoes both sides,
brackets and small items for built in and for making good
all work disturbed including cutting back reinforcement or
cutting out cramps where abutting concrete columns,
cleaning and preparing the floor and ceiling abutments
for new finishings. (Fair facing of brick walls is measured
separately)

1.3.2.7 The term "taking down" or "taking up" or "taking out" and
"setting aside for re-use" shall mean the execution
complete by the Contractor of the work of taking down or
taking up, or taking out an existing article, fitting, or
material, and setting same aside on Site for subsequent
re-use and, notwithstanding the requirements of the
Standard Method of Measurement clause 3.01(d), the
rates shall be deemed to include for:

(a) carefully taking down, taking up or taking out of the


article, fitting or material complete with plugs,
holdfasts, lugs, brackets and other fixings including
dismantling if necessary and all cutting out

(b) thoroughly cleaning, maintaining and adjusting the


article fitting or material ready for re-use including
dismantling and re-assembling again as necessary
and moving and stacking or putting into store on Site

(c) making good to all work disturbed at fixings and any


damage to surrounding surfaces including filling all
mortices, holes, etc, or alternatively leaving same
open and clean ready to receive old or new article,
fitting or material

P-5
1.0 GENERAL (CONT’D)

1.3 ALTERATIONS (CONT’D)

1.3.2 Terms (Cont’d)

1.3.2.7 The term "taking down" or "taking up" or "taking out" and
"setting aside for re-use" shall mean the execution
complete by the Contractor of the work of taking down or
taking up, or taking out an existing article, fitting, or
material, and setting same aside on Site for subsequent
re-use and, notwithstanding the requirements of the
Standard Method of Measurement clause 3.01(d), the
rates shall be deemed to include for: (Cont‟d)

(d) preparing edges, ends, or surfaces of remaining


material to receive junction with new
(e) repairing any damage to the article, fitting, or material
caused during taking down, etc

1.3.2.8 Any repairs required to the article, fitting or material


except for cleaning, maintaining, adjusting or making
good damage caused during taking down, etc, and
re-fixing in new positions, will be measured and paid for
separately

1.3.2.9 The term "re-fixing" or "re-hanging" shall mean the


execution complete by the Contractor of the work of
re-fixing and jointing and article, fitting or material and the
rates shall be held to include for:

(a) taking the article, fitting or material from store on Site,


sorting, cutting and fitting, fabricating, assembling,
moving, hoisting, fixing, laying or setting and jointing
in new or existing work, opening or position

(b) providing all fixing and jointing materials such as


nails, bolts, nuts, washers, screws, mastic, adhesive
and mortar

(c) executing all plugging and screwing, jointing, cutting


all mortices and grouting same, executing all cutting,
fitting, easing or adapting necessary to the article,
fitting or material or to the position in which same is to
be fixed, and oiling and leaving in working order

(d) making good any damage caused to the article, fitting


or materials, and to surrounding surfaces

P-6
1.0 GENERAL (CONT’D)

1.3 ALTERATIONS (CONT’D)

1.3.2 Terms (Cont’d)

1.3.2.10The rates for cutting new openings or enlarging existing


openings shall be held to include for all needling,
propping and temporary shoring as necessary to support
the surrounding structures, for altering and adapting as
necessary and for removing when no longer required
and for making good all work disturbed and for levelling
for sills, cutting toothings and providing and bonding in
any new bricks required, and preparing jambs and head
ready to receive new plaster or other finish, cutting and
pinning in ends of new sills, lintels, fixing lugs, cramps,
bolts etc and clearing away all debris
1.3.2.11Taking down timber doors, shall be taken out complete
with all ironmongery, frames, lining, sills, architraves,
grounds, cramps, dowels, etc where so described.

1.3.2.12The rates for removing all ironmongery shall be held to


include for "piecing out" and filling all old sinkings,
housings, screw holes, mortices or similar in the timber
or other surfaces to which the articles of ironmongery
was fixed, and preparing surface to receive new
decoration

1.3.2.13The rates for taking down metal doors shall be held to


include for taking down frames and thresholds and
cutting out lugs, cramps etc for removing all control gear
and ancillary items such as hooks, stops, etc

1.3.2.14The rates for blocking up openings and recesses shall be


held to include for preparing the existing work for raising,
cutting, toothing and bonding to existing at jambs of
opening and wedging and pinning up to existing work

2.1 PILING

2.2 Generally

2.2.1 The diameter specified for bakau pipe applies to piles with
reasonably uniform diameter throughout the length and is
measured at mid length.

2.2.2 All piling is driven from existing ground levels unless otherwise
stated

P-7
2.0 PILING (CONT’D)

2.2 Measurement

2.2.1 Piles given in m shall be measured from the cut-off level to the
toe of the piles after driven.
2.2.2 The area of interlocking piles shall be measured by multiplying
the mean undeveloped horizontal lengths of the pile walls formed
(including lengths occupied by special piles) by the depths.
Depth is measured from the formation level of the ground to the
bottom edge of the piles after driven.
2.3 Rates

2.3.1 Rates for each type of piling shall be held to include for:

(a) all labour and material for the complete pile including
wastage above cut-off level

(b) e xt e n d in g o f p ile a s re qu i re d

(c) all excavation and surfacing necessary for or incidental to


the installation of the piling including removal of
obstructions encountered

(d) piling through all types of sub-soil strata encountered in the


ground as found
(e) all standing time for or removal and re-establishment of
equipment except where work is suspended due to an
Superintending Officer's Instruction

(f) splicing of steel piles or jointing of pile

2.3.2 Rates for timber piles shall be held to include for:

(a) supplying, transporting, handling, driving and pitching


(b) cutting off head of piles to required level
(c) driving piles down to required set
(d) application of wood preservative to cut off surface of piles

2.3.3 Rates for each item of precast concrete piles shall be held to
include for moulds, reinforcement, extra labour and materials to
receive pile extensions, preparing heads and integrating
reinforcement to pile caps.

P-8
2.0 PILING (CONT’D)

2.3 Rates (Cont’d)

2.3.4 Rates for each item of steel sheet piles shall be held to include for
covers, functions, closure and taper piles.

2.3.5 Rates for each item of temporary steel sheet piles shall be held to
include for the provision for credit value and extraction of the pile.
2.3.6 Rates for each item for bored piles shall be held to include for
boring and disposal of the spoil and preparation of heads to
receive pile caps.

2.3.7 Rates for cutting off heads of piles shall be held to include all
necessary excavation, disposal or backfilling, disposal of debris,
and cleaning, straightening and bending any projecting
reinforcement.

2.3.8 Rates for test loading of piles shall be held to include for
temporary pile caps, anchors, platforms, loading materials,
monitoring of tests and the like.

3.1 EXCAVATION

3.2 Generally

3.2.1 All rates for excavation in the Fixed Schedule of Rates shall be
applicable to:

(a) excavation by hand or machine over flat around pile or within


confined site.

(b) excavation of ‘ordinary ground’.

3.2.2 Ordinary ground‟ includes spoil, rubbish, sand, gravel,


decomposed granite, red or white earth, loamy or gravely clay,
gravely laterite, mud, bog and the like.

3.2.3 Rock‟ shall mean hard material whose geological nature is to be


regarded as such and individual boulder exceeding 0.20m3 or
other hard natural material which necessitates the use of blasting
or approved pneumatic tools for its excavation and removal.

P-9
3.0 EXCAVATION (CONT’D)

3.2 Measurement

3.2.1 The measurement of all excavation and filling is based upon the
average existing ground level.
3.2.2 The quantities of excavation and filling shall be measured on the
assumption that the gradient of the existing surfaces between the
nearest adjacent spot levels and/or between contours is constant.
No quantity adjustment shall be made for any additional
excavation or filling required due to variations of the existing
surfaces differing from a constant gradient between spot level.

3.2.3 All excavation, filling and disposal shall be measured nett. No


allowance shall be made for increase in bulk and any extra
excavation required for planking and strutting and formwork for
concrete.

3.2.4 No allowance f or working space shall be made in the


measurement of all excavation unless the method of construction
requires workmen to operate from the outside of the structure. In
such case, an allowance of working space of 600mm shall be
measured from the external face of the structure.

3.3 Terms

3.3.1 The term “getting out” includes for all wheeling, basketing or
hoisting out, multiple handling and/or placing excavated material in
temporary spoil heaps as may be necessary and preparatory to
backfilling or disposal.

3.3.2 The term “backfilling” or “disposal” shall mean either return, fill and
ram selected excavated material around foundation and/or remove
surplus excavated material off Site to a tip provided by the
Contractor.

3.3.3 The term “planking and strutting” shall mean providing everything
requisite to uphold the face of all excavation

P-10
3.0 EXCAVATION (CONT’D)

3.4 Rates

3.4.1 Rates for each item of the excavations shall include for
excavating around piles and confined areas, excavating in stages,
multiple-handing between excavation and final positions, getting
out, removing of bakau piles, trimming, levelling and compacting
bottoms of excavations, making good any subsidence, slip or
denudation, keeping sides plumb, planking and strutting (exclude
special shoring) and keeping the Site and all excavation free from
all water by pumping or baling and providing any temporary
drains if required.

3.4.2 Rates for disposal of excavated material shall be held to include


the provision for transport, loading and unloading and a shoot,
dump or tip.
3.4.3 Rates for filling to make up levels, embankments or terraces shall
include for all multiple-handling, spreading and leveling, watering
if required, filling in layer, well compacting, temporary retaining
boards and for consolidated quantities.

4.1 CONCRETE WORK

4.2 Measurement

4.2.1 No deduction shall be made in the measurement for in -situ


concrete for:
(i) voids of 0.05m 3 or less
(ii) volume of the reinforcement, steel sections and cast in
accessories.
(iii) openings in walls, floors and the like of 0.10m 2 or less

4.2.2 No deduction shall be made for opening in the measurement of


fabric reinforcement less than 1 .00m2.

4.2.3 No deduction shall be made in the measurement for formwork for:

(i) openings of 1 .00m2 or less


(ii) intersection of main and secondary beams
(iii)intersection of beams and stanchion or columns

4.2.4 Formwork shall be measured to the surface of work sloping more


than 15 degrees from the horizontal.

P-11
4.0
CONCRETE WORK (CONT’D)
4.1
Measurement (Cont’d)

4.1.5 The following weights per linear metre of reinforcing bar shall be
used in calculating the total weights of reinforcement (regardless
of actual weight)

Diameter kg/m
6mm 0.222
10mm 0.616
13mm 1.042
16mm 1.579
20mm 2.466
22mm 2.984
25mm 3.854
28mm 4.834
32mm 6.313
35mm 7.553
38mm 8.903
40mm 9.865

4.2 Rates

4.2.1 Rates for each item of in-situ concrete shall be held to include for
pour joints, forming or cutting grooves, chases, mortices, holes,
openings not exceeding 0.10m 2, laying on any type of sub-base,
laid to falls, currents or cambers, compacting concrete by tamping
or vibrating, working between and around reinforcement and
making good and any other sundry items of a like nature.

4.2.2 Rates for each item of reinforcement shall be held to include for
cleaning and wire-brushing bars to remove rust, dust, mill scale,
dirt, oil and other deleterious matters, cutting, bending,
fabricating, placing, tying wire, non-designed spaces or chairs,
temporary fixings and supports.

4.2.3 Rates for each item of fabric reinforcement shall be held to


include for bending, welding, extra material at laps and notchings
around obstructions.

4.2.4 Rates for prestressing tendons shall include for degreasing,


straightening, cutting to lengths, assembling, hoisting, fixing,
cones, wedges, anchor plates, spacers and the like including the
provision of jacks filling-in to jacking or anchor recess and cutting
the ends of tendons at both ends and extra materials and waste.

P-12
4.0 CONCRETE WORK (CONT’D)

4.2 Rates (Cont’d)

4.2.5 Rates for each item of formwork shall be held to include all
necessary boardings, supports, erecting framing, cutting,
perforations for pipes, angles, cleaning, wetting and treatment
with mould oil, forming chamfered edges and splayed internal
angles not exceeding 50mm wide notching allowance for overlaps
and passings of angles, battens, struttings, bolting, wedging,
easing, striking and removal of formwork and for all raking and
circular cutting.

4.2.6 Rate for wrought formwork shall include for lining the formwork
with suitable materials including cleaning off any fins remaining
on the surfaces of the concrete after removal of the formwork and
for making good any honeycombing or irregularities and for
leaving the concrete with a true and even face and making good
irregularities.
4.2.7 The rates for precast members shall include for concrete,
reinforcement, stressing wires, formwork including the formation
and filling of pockets, holes, chases and recesses for anchors,
bolts and the like, grouting, painting of joints, surface finishes,
delivery, unloading, hoisting, erecting, fixing including all
necessary temporary erection gear, bracing and working
platforms.

4.2.8 The rates for precast concrete hollow core slabs shall include for
the provision of recesses, brackets, embedded fixtures, coved
openings and other services, sealing the voids with approved
epoxy, concrete or other materials, hoisting with a lifting beams
and top-lift clamps and necessary safety chains or belts and
conforming to watertightness as required.

5.1 BRICKWORK AND BLOCKWORK

5.2 Generally

5.1.1 All wall thickness given in the Fixed Schedule of Rates are
nominal thickness.

P-13
5.0 BRICKWORK AND BLOCKWORK (CONT’D)

5.2 Measurement

5.2.1 No deductions shall be made for in the measurement of brickwork


and blockwork for :
i. openings of 0.50m 2 or less
ii. Strings, sills, lintols and the like only when exceeding 100mm
in height
5.3 Rates

5.3.1 Rates for each item of brickwork and facings shall be held to
include for all holdfasts and bonding ties at abutments to concrete
structures, all rough and fair cuttings, oversailing and receding
courses, rough relieving and discharging arches, wedging and
pinning, raking out joints for and pointing flashings, bedding
plates, bedding and pointing wood frames, parging and coring
flues and labour eaves, filling, plumbing angles, forming square
and rebated reveals, cut squints and birdsmouths, notches,
forming leaving or cutting chases, holes and mortices, cutting and
pinning and making good and other sundry items of a like nature.

5.3.2 Rates for each item of brickwork and facing shall apply equally to
new brickwork to existing walls or structures and new brickwork in
filling opening including hacking and preparing existing floor, wall
and ceiling finishes to receive new brickwork, making good all
work disturbed to match existing and extra labour and materials
for toothing and bonding.

5.3.3 Rates for each item of brickwork and facings shall apply equally
to brickwork in thickening existing walls, brickwork in tapered
walls and walls with battering face, brickwork circular on plan and
to brickwork in manholes (unless otherwise mentioned), including
forming openings in walls for drain pipes and turning arches over
same where required and all templates.

5.3.4 Rates for each item of blockwork shall be held to include for all
purpose-made or special-made blocks, (or brickwork and/or in –

situ concrete in lieu) all holdfast and bonding tiles at abutments to


oversailing and receding courses, free ends, plumbing angles,
forming square and rebated reveals, notches, cutting and pinning
at top , cutting at ends and around openings, cutting and bending
to intersections, angles and irregular angles, raking out joints for
and pointing flashings, bedding and pointing wood frames,
parging and coring flues, labour eaves filling, notches, forming,
leaving or cutting chases, holes and mortices, cutting and pinning
and making good and any other sundry items of a like nature.

P-14
5.0 BRICKWORK AND BLOCKWORK (CONT’D)

5.3 Rates (Cont’d)

5.3.5 Rates for each item of blockwork shall apply equally to new
blockwork to existing or different types of walls or structures and
new blockwork in filling opening including hacking and preparing
existing floor, wall and ceiling finishes to receive new blockwork,
making good all work disturbed to match existing and extra labour
and materials for toothing and bonding.

5.3.6 Rates for each item of glass blockwork shall be held to include for
reinforcement strip, bedding, raking and pointing joints, bitumen
emulsion, coating, fiberglass covering strips, mastic compound
and any other sundry items of a like nature.

6.1 ROOFING

6.2 Measurement

6.2.1 All works including flat roof gutters, skirtings, upstands, upturns,
edges, parapet walls, cladding and the like shall be measured in
the net area covered.

6.2.2 No deduction shall be made in the measurement of roofing work


for voids of 0.50m2 or less.

6.3 Rates

6.3.1 Rates for all types of roofing materials shall be held to include
small quantities, laps, all necessary fixing, cutting and waste and
all necessary sundry materials, equipment, tools, fuel, labour for
hoisting and fixing, protection against weather, clearing blockage
and maintaining all existing rainwater goods during the progress
of the works, making good all existing works such as outlets,
services, etc. affected and temporary diversion of existing
services.

6.3.2 Rates for each item of tile roofing shall be held to include small
quantities, laps, skew and circular cutting at eaves, verges, top
edges, abutments, valleys and hips, cutting holes for pipes, nails,
screws, clips, pellets, strips and the like, fair ends, stops and
intersections.

P-15
6.0 ROOFING (CONT’D)

6.2 Rates (Cont’d)

6.2.3 Rates for each item of built-up membrane roofing together with its
associated underbeds, insulation, concrete toppings/panels and
the likes shall be held to include narrow widths, temporary screed,
running rules, covering up, all labour and materials to form
arrises, fair edges, finishing to eaves and verges, skirtings,
upstands, turn-up, aprons, gutters, ridges, hips and valleys, etc.
and all cuttings and working around pipes and the likes, angle
fillets, fair ends, short lengths, junction, chasing the structure for
burning-in or tucking in edges of coverings, flashings and the like.

6.2.4 Rates for each item of profiled sheet roofing or cladding shall be
held to include all cutting at square and raking abutments, top
edges, bedding and pointing eaves fillers, verges, cutting and
fitting and making good around outlets, pipes and any other
sundry items of a like nature.

6.2.5 Rates for each item of flashings shall be held to include dressing
over roofing works, laps, seams, rolls, dressing wedging into
grooves, hollow, channels, recess, angles, returned and stopped
ends and intersections.

6.3 Warranty

6.3.1 Waterproofing warranty shall be submitted after all waterproofing


works have been carried out and the warranty period shall be as
follows:

1) Area not exceeding 50m2 - No guarantee


2) Area exceeding 50m2 and not exceeding 500m2 - 5 years
(min) guarantee
3) Area exceeding 500mm2 - 10 years (min) guarantee

7.1 CARPENTRY AND JOINERY

7.2 Generally

7.2.1 Unless otherwise stated, all timber sizes stated are finished size.

7.2.2 Where a door thickness is stated, such thickness is inclusive of


any plastic, metal or other facings unless otherwise stated.

7.3 Measurement

7.3.1 No deductions shall be made for in the measurement of joinery


work for openings of 0.50m2 or less.

P-16
7.0 CARPENTRY AND JOINERY (CONT’D)

7.3 Rates

7.3.1 Rates for each item of carpentry work shall be held to include for
all cutting, notching, boring, sinking, pelleting, fitting, trimming,
mitring, halving, morticing, tenoning, dovetailing, scarfing and
wedging and all ends, splayed edges, short lengths and
temporary supports and any other sundry items of a like nature
and also all labour in forming, drilling for bolts and fixing in
position complete with nails, screws or adhesives.
7.3.2 Rates for wallboard, hardboard, plywood and other sheet
materials of a like nature where used for lining ceilings and walls,
dados, jambs, fittings, fitments, and the like shall be held to
include for narrow widths, small quantities, all cutting and making
holes for pipes, nails, screws or adhesives.

7.3.3 Rates for each item of joinery work shall be held to include for all
nailing, gluing, screwing, plugging, cutting, notching, holes,
housing ends, mitring, ends, and shaped ends, angles, junctions,
heading joints, short lengths, tongued angles, splayed or rounded
edge, chamfers, rebates, grooves and any other sundry items of
a like nature including stops and working cross-grain, and
finishing off with sanding machine and polishing surfaces of
wrought loadwork.

7.3.4 Rates for carpentry and joinery work shall be held to include
fitting, hanging, fixed in position, wedging, plugging to adjacent
structure including all screws, nails, pins or brads, short lengths,
cleats, sprockets and the like.

7.3.5 Rates for insulation and sarking shall be held to include laps,
fixing, cutting to sizes, stitching up edges, handing and
overlapping.

8.1 IRONMONGERY

8.2 Rates for each item for ironmongery work shall be held to include all
matching screws, nails, pins or brads of the same finish as the
ironmongery, cutting, sinking, boring and morticing the element for fixing
ironmongery, fitting, oiling and easing, taking off and refixing after
painting where necessary, handling over properly keys on completion
and leaving in perfect working order.

P-17
8.0 IRONMONGERY (CONT’D)

8.2 Rates for each items of lockset shall be held to include three keys.

8.3 Rates for each items for fixing ironmongery shall not varied if the type,
size, etc. of ironmongery items varied during the Contract.

9.1 STRUCTURAL STEELWORK

9.2 Measurement

9.2.1 No deduction shall be made in the measurement of structural


steelwork for drillings, holes, notchings, splay cuts and the like.

9.2.2 No allowance shall be made in the measurement of structural


steelwork for rolling margins and the weight of welding materials.
9.2.3 Weights in the Fixed Schedule of Rates shall be net theoretical
weights.

9.3 Rates

9.3.1 Rates for each item of structural steelwork shall be held to


include:

(a) shop and site fabrication including drilling, cutting (including


holes and openings for other trades) notching, splicing,
welding, machining ends and bearings, delivery, unloading,
landing, hoisting, erecting, fitting and fixing in position.

(b) provision of all necessary plant, temporary bracing supports


and the like required for erection, providing samples and tests
required by the Specification, the inspection of welds including
the use of any special radiographic techniques.

(c) nuts and type of washer which may be required.

(d) preparation of shop drawings.

10.1 METALWORK

10.2 Measurement

10.1.1 No deduction shall be made in the measurement of metalwork for


drillings, holes, notchings, splay cuts and the like.

P-18
10.1 METALWORK (CONT’D)

10.2 Measurement (Cont’d)

10.2.2 No deduction shall be made in the measurement of metalwork for


openings of 0.50m2 or less.
10.2.3 No allowance shall be made in the measurement of metalwork for
rolling margins and the weight of welding materials.

10.2.4 Weights in the Fixed Schedule of Rates shall be net theoretical


weights.

10.3 Rates

10.2.1 Rates for each item of metalwork shall be held to include:

(a) cutting, notching, mitring, welding, fabricating, drilling, delivery,


unloading, handling, assembling, hoisting, fitting and fixing in
position, bedding, filling in solid and painting including
necessary lugs or other attachments.

(b) protection such as wrapping finished work with paper, coating


with grease or carrying out such other protective measures as
may be required and removing and cleaning on completion.

(c) providing samples and testing as required.

(d) p rim in g wit h t wo c oa t s of red le ad p rime r p rio r to


fixing/installation.

(e) preparation of shop drawings.

10.2.2 Rates for balustrades and handrails shall be held to include


running lengths, mitring, ramps, wreaths, bends, terminals, scrolls
and the like.

11.1 WALL AND CEILING FINISHINGS

11.2 Generally

11.2.1 Unless otherwise stated, the rates in the Fixed Schedule of Rates
are applicable to internal and external work.

11.2.2 Unless otherwise stated, the Fixed Schedule of Rates are


applicable to works at ceiling and vertical surfaces.
11.2.3 All rendered backing to receive finishes shall be measured
separately.

P-19
11.0 WALL AND CEILING FINISHINGS (CONT’D)

11.2 Measurement

11.2.1 All work except as hereinafter provided, shall be given in m2 and


unless otherwise stated shall be measured the net area covered.

11.2.2 No deduction shall be made for the measurement of wall and


ceiling finishings for openings of 0.50m2 or less.

11.2.3 All vertical surfaces not exceed ing 300mm high shall be
measured as skirtings under the „Floor Finishings‟ section.

11.2.4 Suspended ceilings have been measured over edge trims, grilles,
registers, light fittings, access panels and the like.

11.3 Rates

11.3.1 Where suspended ceilings are to be installed without cornices,


coves or trims, all work to walls, columns and other vertical
surfaces shall be measured to extend above the finished level of
the ceilings. Unless shown as exceeding 50mm, an allowance of
50mm shall be made for height of the work above the finished
ceiling level.

11.3.2 Rates for each item of wall and ceiling finishes shall be held to
include :

(a) preparing surfaces to receive finishes such as raking out joints


of brickwork or blockwork, hacking concrete or rendered
backing to form keys and rubbing and cleaning old walls.

(b) all temporary rules, temporary grounds, temporary screeds


and the like, cramps, dowels, ties, special metal supporting
brackets and the like, cutting holes, notching and the like,
masking, labour to internal angles other than coved angles,
making good around pipes, sanitary fixtures and the like, work
in narrow widths and small quantities, joints between different
types of works, joints between new and old work, old internal
angles, fair edges, rounded or chamfered edges or angles,
arises, quirks, grooves, V-joints, groin points, and other
intersections of curved surfaces, rounded coves and external
angles not exceeding 25mm radius, mitres, stops and the like
on cornices, mouldings, architraves, coves, skirtings, gutters,
strings and all making good and any other sundry items of a
like nature.

P-20
11.0 WALL AND CEILING FINISHINGS (CONT’D)

11.2 Rates (Cont’d)

11.3.2 Rates for each item of wall and ceiling finishes shall be held to
include : (Cont‟d)

(c) Rates for each item of wall tiling shall be held to include for
laying to approved patterns, narrow widths, small quantities,
raking or circular cuttings, fitting around bars, pipes and the
like, rounded edge tiles, coved internal angle tiles, rounded
external angle tiles, all short lengths, cut and special made
angles, junctions, ends and making good and any sundry
items of a like nature, soaking tiles in water, forming keys on
existing or new substrate and cement slurry where necessary.
(d) Rates for cutting, cracks, chases and the like on existing wall
and ceiling finishings shall be held to include chisel and
diamond cutting, all necessary tools and appliances,
temporary lines, clearing away debris and preparing substrate.

11.3.3 Rates for each item of proprietary suspended ceilings shall be


held to include for:

(a) installation complete with linings and including the whole of


the suspension system (ie suspension framing, edge trims,
hangers fastenings, anchors, connectors, clips, grips, cleats,
etc. and fixing to soffits).

(b) laying to approved patterns all cutting, small quantities, narrow


widths, trimming around pipes, conduits, power points,
sleeves, sprinkler and detector heads, openings, grilles,
registers, light fittings, access panels and the like, including
extra supports and trimmers for same.

(c) additional framing and supports, etc. to bridge across ducts,


stiffeners to linings, etc.

12.1 FLOOR FINISHINGS

12.2 Generally

12.2.1 Unless otherwise stated, the Fixed Schedule of Rates are


applicable to internal and external work.
12.2.2 Unless otherwise stated, the Fixed Schedule of Rates are
applicable to work at horizontal surfaces exceeding 300mm wide.

P-21
12.0 FLOOR FINISHINGS (CONT’D)

12.1 Generally (Cont’d)

12.1.3 The rates for skirtings shall be applicable to the following:

(a) drops, risers, sides of plinths, kerbs and other vertical


surfaces not exceeding 300mm high.

(b) treads, top of kerbs and other horizontal surfaces not


exceeding 300mm wide.

12.2 Measurement

12.2.1 All works except as hereinafter provided, shall be given in m2 and


unless otherwise stated shall be measured the net area covered.

12.2.2 All vertical surfaces exceeding 300mm high shall be measured


under „Wall And Ceiling Finishings Section.

12.2.3 Screed backing to receive finishes shall be measured separately.

12.2.4 No deduction shall be made in the measurement of floor


finishings for openings of 0.50m2 or less.

12.3 Rates

12.3.1 Rates for each item of floor finishes shall be held to include for:

(a) preparing surfaces to receive finishes such as hacking


concrete or screed backing to form keys.

(b) all temporary rules, temporary grounds, temporary screeds


and the like, cutting holes, notching and the like, all normal
bedding and pointing materials, providing all necessary
samples, cleaning down and making good around pipes,
sanitary fixtures and the like, work in narrow widths and small
quantities in areas interrupted by seatings, channels and the
like, all internal angles, quirks, grooves, throats, drips, coves
and rounded external angles not exceeding 25mm radius,
angles, stops, intersections, fair ends, junctions, wreathed
corners and the like on cornices, mouldings, enrichments,
coves, skirtings, gutters, channels, strings, kerbs and similar
or other sundry items of a like nature.

(c) protecting surfaces from the weather or building operations.

P-22
12.0 FLOOR FINISHINGS (CONT’D)

12.3 Rates (Cont’d)

12.3.2 Rates for each item of skirtings, risers, moulded or rounded


edges, channels and the like shall be deemed to include all short
lengths, formed, cut and purpose made angles, junctions, ends
and the like, making good and any other sundry items of a like
nature.

12.3.3 Rates for each item of floor tiling shall be held to include for laying
to approved patterns, narrow widths, small quantities, raking or
circular cuttings, fitting around bars, pipes and the like, rounded
edge tiles, coved internal angle tiles, rounded external angle tiles,
all short lengths cut and special made angles, junctions, ends and
making good and any sundry items of a like nature and soaking
tiles in water, forming keys in existing or new substrate and
cement slurry where necessary.

12.4 Waterproofing Warranty

12.4.1 Waterproofing warranty shall be submitted after all waterproofing


works have been carried out and the warranty period shall be of
five (5) years manufacturer‟s guarantee.

13.1 PLUMBING

13.2 Generally

13.2.1 All diameter of pipes described in the Fixed Schedule of Rates


are nominal internal diameter.

13.2.2 Unless otherwise stated, the Fixed Schedule of Rates are


applicable to work outside the boundary of the property.
13.3 Measurement

13.3.1 Pipes shall be measured the net length along the centre lines of
pipes over all bends, junctions, tees, and the like pipe fittings and
except as hereinafter provided shall be given in m.

13.3.2 Pipes 50mm diameter and below shall be held to include all
elbows, bends, tees, junctions, inspection openings, reducers and
similar pipe fittings.

P-23
13.0 PLUMBING (CONT’D)

13.2 Measurement (Cont’d)

13.2.3 Pipes over 50mm diameter whether internal diameter or external


diameter shall have all elbows, bends, tees, junctions, access
openings, reducers and similar pipe fittings shall be measured
separately in No. as extra over the pipes in which they occur.

13.2.4 Excavation and backfilling for pipework laid in the ground shall be
measured under „Drain Excavation‟ in External Works‟ sections.

13.2.5 Pipes chased into walls or floors shall be measured separately


under „Concrete Work, Brickwork And Blockwork Section‟.

13.3 Rates

13.3.1 Rates for each item of pipework shall be held to include:

(a) all cutting and waste, short lengths, joints in the running
lengths, joints to all branches, tees, sockets, sleeves,
connectors, backnuts, nipples, long screws, forming holes,
joints between different pipes, standard pipe fixings or
supporting clips, saddles, fastening brackets, holderbats
straps and the like and for fixing to tiled or cast in situ surfaces
or to new or existing surfaces including making good.

(b) submission of application for permit and giving notices,


complying with all requirements of the relevant authorities,
including new requirements being introduced during the
duration of this Contract, paying fees and the like in
connection with the installations and preparing and submitting
drawings for approval if required, and engaging licensed
plumbers to carry out the Works.

(c) preparation of drawings required by the relevant Authorities


such as the details of the storage tanks inlet overflow and
water level indicator, etc. as specified or shown on the
drawings. The drawings submitted shall be endorsed by the
Professional Engineer.

13.3.2 Rates for copper pipework chased in walls shall be held to


include wrapping with approved building paper and grouted.

13.3.3 All taking out items shall be held to include plugging existing
water supply pipe and making good work disturbed.

P-24
13.0 PLUMBING (CONT’D)

13.3 Rates (Cont’d)

13.3.4 Rates for each items of sanitary appliances and fittings shall be
held to include assembling all component parts, connecting to
service pipes, plugging, screwing, pinning or fixing to wall and
setting in floor, bedding in position, pointing and grouting solid
and making good to surfaces.

14.1 GLAZING

14.2 Generally

14.2.1 All glass thickness given in the Fixed Schedule of Rates are
nominal thickness.

14.3 Measurement

14.3.1 Panes of glass of irregular shape shall be measured the smallest


rectangular area out of which such irregular shape can be cut out.

14.4 Rates

14.4.1 Rates for each item of glazing shall be held to include for:

(a) small quantities, small panes, irregular shapes, all raking and
circular cutting, waste and risks, forming openings in glass,
fixing and bedding, replacing scratched, cracked and broken
glass, cleaning and polishing and all necessary protection.

(b) fixing to metal, timber, concrete and other surfaces, bedding


and fixing with pins, non-corrosive screws and cups, sprigs,
beads, putty, neoprene strip, mastic, silicone sealants and the
like.

(c) polishing, rounding and grinding exposed edge.

15.1 PAINTING AND DECORATING

15.2 Generally
15.1.1 Unless otherwise stated, the Fixed Schedule of Rates are
applicable to Internal and external painting.

P-25
15.0 PAINTING AND DECORATING (CONT’D)

15.2 Measurement

15.2.1 All works shall be measured flat on plane and edges. No


allowance shall be made in the measurement for mouldings,
panellings, sinkings, corrugations, fixings, carvings, enrichments
and the like unless otherwise described.

15.2.2 No deductions shall be made in the measurement for openings of


0.50m2 or less. Works on grilles and the like shall be measured
flat overall on both sides.

15.2.3 Small pipes shall be referred to pipes not exceeding 50mm


diameter.

15.2.4 Large pipes shall be referred to pipes exceeding 50mm diameter


and not exceeding 100mm diameter.
15.3 Rates

15.3.1 Rates for each item of painting and decorating shall be held to
include:

(a) preliminary preparatory works for the surface required before


the application of any material such as cleaning by washing
down with water burning off, stripping existing paintwork or
rubbing down with glass, emery or sandpaper and leaving all
surfaces free from dust, rust, grease and oil before painting.

(b) all multi-coloured work and cutting to line and rubbing down
between two coats.

(c) provision of erection and removal of scaffolding.

(d) use of different types of colours.

(e) protection and/or masking floors, fittings and the like,


removing and fixing door and window furniture, signs and the
like and removing splash and spray marks.

(f) extra labour and materials for painting on surfaces of beads,


hinges and other fittings, brackets, bolts, lugs and the like,
service ducts, conduits, electrical wiring, battens, risers,
switches boxes and blocks in contract with the surface to
match the colour of the surface to which they are fixed.

15.3.2 Rates for each items for paper hanging and linings shall be held
to include cutting and fitting paper around pipes, switches,
brackets and the like.

P-26
16.1 EXTERNAL WORK

16.2 Generally

16.2.1 The relevant preambles in the preceding sections shall apply to


all work in this section unless otherwise provided herein.
16.3 Measurement

16.3.1 Unless otherwise described, excavation and disposal of


excavated material shall be measured separately.

16.3.2 Concrete foundation to kerb shall be measured separately.

16.3.3 Spot and close turfing shall refer to laying grass with gaps not
exceeding 100mm and 30mm respectively.

16.3.4 Piling, hardcore, lean concrete, sand bed or concrete haunching


to drains and culverts shall be measured separately.

16.3.5 The girths of trees in the Fixed Schedule of Rates are measured
at a height of 1 .00m above ground

16.4 Rates

16.4.1 Rates for each item of turfing shall be held to include trimming
and leveling, watering, weeding, fertilizing, cutting, and rolling,
settlement, pegging grass to embankment with wooden pegs.

16.4.2 Rates for each item of granular sub-base materials shall be held
to include trimming, leveling, rolling, grading and compacting
subgrade to required density.

16.4.3 Rates for each item of fencing shall be held to include excavation,
formwork and disposal of excavated materials for concrete base,
drilling and cranking top of main steel with one coat of red lead
primer and two coats of enamel paint.

16.4.4 Rates for each item of precast concrete culverts, drains, pipes
and sumps shall be held to include moulds and formwork, forming
holes, rebates, notchings, sinkings mortices and recesses,
reinforcement, laying in trench or open ground, jointing and
pointing in cement mortar.

16.4.5 Rates for each item of plants shall be held to include soil,
packings and removal of wrapping, watering, weeding, fertilizing,
sticks or props support and remove when the plants stabilized.

P-27
16.0 EXTERNAL WORK (CONT’D)

16.4 Testing And Maintenance Manual

16.4.1Testing and Maintenance Manual Guide is to be submitted after


laying of new synthetic grass for hockey and soccer field and any
other field using synthetic grass. All testing on synthetic grass
shall be in accordance to FIFA testing guidelines.

16.5 Maintenance Of Synthetic Field

16.5.1 The maintenance of the synthetic field shall be carried out two (2)
times per year and all inspection and maintenance shall comply
with the Federation Internationale de Football Association (FIFA)
guidelines / standards and manufacturer‟s guidelines.

1 6.5.2The level of the infill of the synthetic turf shall be maintained such
that the exposed fibres are about 30mm. Areas with insufficient
infill shall be topped up with Styrene-Butadiene rubber granules
of grain size 1mm to 2.5mm using a spreader to spread the
materials evenly and control the exact materials to be laid on the
field (topping up of rubber granules shall be measured
separately).

16.5.3 The entire field shall be brushed to redistribute rubber infill


displaced through use and weather effects. A tractor with turf
tyres shall be used to tow a synthetic field brush or mat to level
the infill. After brushing, a ball roll test shall be conducted
according to Federation Internationale de Football Association
(FIFA) standards to establish that the ball roll characteristics on
the playing field are met.

16.5.4 A tractor with turf tyres shall be used to tow a specialised


equipment to loosen the rubber infill compacted and hardened
over time and through use. The specialised equipment should
consist of spikes, a brush, a grading blade and a roller to loosen
and re-distribute level and refill the synthetic turf. A vertical ball
bounce test shall be conducted according to FIFA standards to
establish the performance of the field.

16.5.4 The entire field shall be brushed / groomed to prevent pile lean
and pile flattening and brushing to keep fibres upright and non-
directional.

16.5.5 Debris shall also be removed from the field.

P-28
16.0 EXTERNAL WORK (CONT’D)

16.6 As-Built Drawing

16.6.1 As-built drawings shall also be submitted after the construction


and laying of the synthetic field. The as-built drawing shall
indicate the field dimensions (including line markings and green
buffer in accordance to Authority‟s requirement), layout of sub-soil
drainage system and field gradient.

16.7 Warranty
16.6.1 All product warranties shall be submitted after constructing and
laying of new synthetic hockey and soccer field and the warranty
period shall be of three (3) years manufacturer‟s guarantee.

17.1 DAYWORK

17.2 Rates shall be applicable in respect of all work executed on a


daywork basis. During the continuance of such work, the
Contractor shall keep proper records of the names, occupations
and working hours of all workmen employed for such work and
the quantities and descriptions of all materials and construction
equipment employed. Such records, receipts or vouchers must be
verified by the Superintending Officer or the Superintending
Officer‟s Representative before payment can be effected.

P-29
SECTION A: PILING
A : PILING

ITEM NO. DESCRIPTION UNIT RATES


(S$)

A1 00000 SITE CLEARANCE

Plant

Providing and assembling the piling equipment on the site


including moving into position and about the site, and the
subsequent dismantling and removal on completion.

A1 00001 rig to install bakau piles Item 661.67

A100002 rig to install timber piles Item 1,140.00

A1 00003 rig to install concrete piles Item 5,616.00

A1 00004 rig to install steel 'H' piles Item 5,616.00

A1 00005 rig to install interlocking steel sheet piles Item 5,616.00

A1 00006 rig to install bored cast in-place concrete piles Item 12,420.00

A200000 WOOD PILES

Bakau piles

Supplying, transporting, handling, pitching, heading,


pointing, providing protective wrought iron rings; drivin g
piles down to an approved set; cutting off tops at required
level where necessary, including all necessary excavation and
disposal of material displaced consequent upon the driving of
the pile.

A200001 7 5 m m - 9 0 m m d i a me t e r b a k a u p i l e s (a t mi d l e n g t h s ) n ot No 6.30
exceeding 4.50m long

A200002 75mm - 90mm diameter bakau piles (at mid lengths) exceeding No 16.37
4.50m and not exceeding 9.00m long in two lengths; jointed
together with steel pipe sleeves

A200003 75mm - 90mm diameter bakau rollers or mattress piles (at mid m 2.35
lengths) laid on excavation

A200004 Provide and assemble piling equipment on site including moving it No 600.00
around site, subsequent dismantling and removal on completion

BW-A1
A : PILING

ITEM NO. DESCRIPTION UNIT RATES


(S$)

A200000
WOOD PILES (CONT'D)

Timber piles

Supplying, transporting, handling, pitching and driving pressure


impregnated timber piles with an approved piling frame and
monkey (transporting of piling frame to and from site
measured separately within site, testing, heading, pointing
and splicing and providing protective wrought iron shoe and
driving down to an approved set and finally cutting off top of
pile to the required level w here necessary) including all
necessary excavation and disposal of material d i s p l a c e d c
on s e q u e nt u p on th e d r i vi ng of t he pi l e

(Penetration length measured).

A200005 100 x 100mm piles m 14.71

A200006 125 x 125mm piles m 19.15

A200007 150 x 150mm piles m 25.69

A200008 175 x 175mm piles m 33.29

Supplying, handling and jointing ends of timber piles /


spiking to pile with 5mm thick mild steel welded box sleeves /
joint

A200009 100 x 100 x 450mm long No 15.90

A200010 125 x 125 x 450mm long No 18.28

A200011 150 x 150 x 450mm long No 20.88

A200012 175 x 175 x 450mm long No 24.90


A200013 Provide and assemble piling equipment on site including moving it No 750.00
around site, subsequent dismantling and removal on completion

Cutting off tops of piles; applying and sealing with wood


preservative

A200014 100 x 100mm piles No 10.00

A200015 125 x 125mm piles No 11.00

A200016 150 x 150mm piles No 12.10

A200017 175 x 175mm piles No 14.00

BW-A2
A : PILING

ITEM NO. DESCRIPTION UNIT RATES


(S$)

A300000 CONCRETE PILES

Precast concrete piles

Supplying, transporting, handling, pitching and driving


precast concrete pile including jointing complying with SS CP
4.

A300001 155 x 155mm cross-section with 25-35 tonne carrying capacity m 19.87

A300002 180 x 180mm cross-section with 35-45 tonne carrying capacity m 23.47

A300003 205 x 205mm cross-section with 45-55 tonne carrying capacity m 28.03

A300004 230 x 230mm cross-section with 55-65 tonne carrying capacity m 31.07

A300005 260 x 260mm cross-section with 65-80 tonne carrying capacity m 39.30

A300006 285 x 285mm cross-section with 80-95 tonne carrying capacity m 41.42

A300007 305 x 305mm cross-section with 95-110 tonne carrying capacity m 49.50

Cutting off heads of precast concrete piles to required cut-off


leve ls; in cluding dis posa l o f debr is and c lean in g,
straightening and bending any projecting reinforcement.

A300008 155 x 155mm piles No 25.00

A300009 180 x 180mm piles No 26.50

A300010 205 x 205mm piles No 27.50

A30001 1 230 x 230mm piles No 31.00

A300012 260 x 260mm piles No 32.60

A300013 285 x 285mm piles No 34.00

A300014 305 x 305mm piles No 38.00

Extra over Portland Cement piles for sulphur resisting


concrete.

A300015 155 x 155mm piles m 1.60

A300016 180 x 180mm piles m 1.94

BW-A3
A : PILING

ITEM NO. DESCRIPTION UNIT RATES


(S$)

A300000 CONCRETE PILES (CONT'D)


Precast concrete piles (Cont'd)

Extra over Portland Cement piles for sulphur resisting


concrete (Cont'd)

A300017 205 x 205mm piles m 2.52

A300018 230 x 230mm piles m 3.24

A300019 260 x 260mm piles m 4.10

A300020 285 x 285mm piles m 4.97

A300021 305 x 305mm piles m 5.72

Bored piles

Designing, supplying and installing bored cast in-place


concrete (Grade 35) concrete piles to carry out the design
working load (reinforcement measured separately)

A300022 500mm diameter m 105.67

A300023 600mm diameter m 127.67

A300024 750mm diameter m 179.00

A300025 900mm diameter m 224.40

A300026 1050mm diameter m 296.70

A300027 1200mm diameter m 351.70

A300028 1350mm diameter m 449.40

A300029 500mm diameter m 110.00

A300030 600mm diameter m 132.00

A300031 750mm diameter m 184.33

A300032 900mm diameter m 233.33

A300033 1050mm diameter m 306.67

BW-A4
A : PILING

ITEM NO. DESCRIPTION UNIT RATES


(S$)

A300000
CONCRETE PILES (CONT'D)

Bored piles (Cont'd)

Designing, supplying and installing bored cast in-place


concrete (Grade 40) concrete piles to carry out the design
working load (reinforcement measured separately) (Cont'd)

A300034 1200mm diameter m 361.00

A300035 1350mm diameter m 462.00

Permanent steel casing

A300036 kg 3.17
Supplying and driving permanent steel casing to be left-in for
bored cast in-situ concrete piles

Reinforcement in bored cast in-place concrete piles.


A300037 kg 0.93
6mm to 16mm diameter mild steel rod in links, stirrups, binders,
curved and helical reinforcement
A300038 kg 0.93
13mm to 25mm diameter high tensile deformed reinforcement
bars

Cutting off heads of bored cast in-place concrete piles to


required cut-off levels; including disposal of debris and
cleaning, straightening and bending any projecting
reinforcement

A300039 500mm diameter No 106.67

A300040 600mm diameter No 113.33

A300041 750mm diameter No 131.33

A300042 900mm diameter No 144.00

A300043 1050mm diameter No 163.70

A300044 1200mm diameter No 178.00

A300045 1350mm diameter No 206.00

BW-A5
A : PILING

ITEM NO. DESCRIPTION UNIT RATES


(S$)

A400000
STEEL PILES

Isolated steel piles

Supplying, transporting, handling, pitching 'H' piles complying


with BS 4360, grade 43A with corrosion protection to BS 5493
and BS CP 1021 including extension by weld jointing to BS
5135 and BS 6265

A400001 203 x 203mm x 53.57 kg/m m 134.00

A400002 254 x 254mm x 62.5 kg/m m 157.00

A400003 305 x 305mm x 78.87 kg/m m 198.00

A400004 330 x 330mm x 108.36 kg/m m 271.00

A400005 356 x 356mm x 132.44 kg/m m 332.00

Cutting off heads of steel piles to required cut-off levels;


including disposal of debris and cleaning, welding capping
plate with starter bars

A400006 203 x 203mm x 53.57 kg/m No 235.98

A400007 254 x 254mm x 62.5 kg/m No 245.70

A400008 305 x 305mm x 78.87 kg/m No 250.90

A400009 330 x 330mm x 108.36 kg/m No 257.04

A400010 356 x 356mm x 132.44 kg/m No 262.70

Interlocking piles

Supplying, transporting, handling, pitching and driving left in


steel sheet piles complying with BS 4360 Grade 43A including
initial trenching, strutting, waling and extension by weld
jointing to BS 5135 and BS6265.

A40001 1 400 x 125 x 13mm thick, 150 kg/m2 U-shaped section m2 220.00

A400012 400 x 150 x 13.1m thick, 146 kg/m2 U-shaped section m2 250.00

A400013 400 x 170 x 15.5mm thick, 190 kg/m2 U-shaped section m2 300.00

BW-A6
A : PILING

ITEM NO. DESCRIPTION UNIT RATES


(S$)

A400000 STEEL PILES (CONT'D)

Driving and extracting steel sheet piles

A400014 Supplying labour, machinery and equipment for driving and m2 75.00
extracting steel sheet piles including provision of steel sheet piles
(any size) and removing piles off site

Cutting or burning through steel sheet piles

A400015 Cutting or burning through steel sheet piles m 50.00

A500000 TEST LOADING OF PILES

Pile test

A500001 tonne 37.30


Test loading of piles with the kentledge reaction system including
casting and subsequent removal of temporary pile cap

A500002 Item 1,500.00


Conducting pile dynamic analysis (PDA) testing by the accredited
tester and to the approval of the SO

BW-A7
SECTION B: EXCAVATION
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B100000 SITE CLEARANCE

Breaking up concrete bases (including excavation around


base) to posts, gate stops, etc, removing debris off site and
filling voids with earth to be obtained from contractor's own
sources and making good work disturbed

B100001 Not exceeding 0.10 m3


No 9.35

B100002 Exceeding 0.10 m3 and not exceeding 0.30 m3 No 25.52


m3 40.90
B100003 Taking out silt, loose muddy soil or other materials from existing
running stormwater channels, drains exceeding 150 mm deep,
sump pits or cesspits removing and depositing, spreading in
positions as directed by the SO or remove off site

B100004 Taking out silt, loose muddy soil or other materials from existing m 1.21
running stormwater channels, drains not exceeding 150 mm deep,
sump pits or cesspits removing and depositing, spreading in
positions as directed by the SO or remove off site

B100005 Taking out silt, loose muddy soil or other materials from existing m 2.78
running stormwater channels, drains not exceeding 150 mm deep,
sump pits or cesspits remove off site as directed by the SO
including clearing grass on one or both sides or drains

B100006 Clearing level or sloping site for removal of tall grasses, shrubs, m2 2.30
bushes, undergrowth, and the like including small trees not
exceeding 600 mm girth at a height of 1.00 m above ground and
grubbing up roots and filling voids with earth obtained from
Contractor's own source and making good ground disturbed

Cutting down tree and grubbing up roots including removing


off site, filling voids in ground with earth obtained from
Contractor's own source and making good ground disturbed
(girth measured at a height of 1.00 m above ground)

B100007 Not exceeding 600mm girth No 300.00

B100008 Exceeding 600mm and not exceeding 900mm girth No 350.00

B1 00009 Exceeding 900mm and not exceeding 1 .20m girth No 400.00

B1 00010 Exceeding 1 .20m and not exceeding 1 .50m girth No 450.00

B1 00011 Exceeding 1 .50m and not exceeding 1 .80m girth No 500.00

BW-B1
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B100000 SITE CLEARANCE (CONT'D)

Cutting down tree and grubbing up roots including removing


off site, filling voids in ground with earth obtained from
Contractor's own source and making good ground disturbed
(girth measured at a height of 1.00 m above ground) (Cont'd)

B100012 Exceeding 1.80m and not exceeding 2.10m girth No 550.00

B100013 Exceeding 2.10m and not exceeding 2.40m girth No 600.00

B100014 Exceeding 2.40m and not exceeding 2.70m girth No 650.00

B100015 Exceeding 2.70m and not exceeding 3.00m girth No 700.00

Cutting down tree (to ground level), remove off site and apply
one coat wood preservative to cut-off surface (girth
measured at a height of 1.00 m above ground)

B100016 Not exceeding 600mm girth No 125.00

B100017 Exceeding 600mm and not exceeding 900mm girth No 178.80

B1 00018 Exceeding 900mm and not exceeding 1 .20m girth No 221.60

B1 00019 Exceeding 1 .20m and not exceeding 1 .50m girth No 256.50

B1 00020 Exceeding 1 .50m and not exceeding 1 .80m girth No 313.40

B100021 Exceeding 1.80m and not exceeding 2.10m girth No 326.70

B100022 Exceeding 2.10m and not exceeding 2.40m girth No 353.70

B100023 Exceeding 2.40m and not exceeding 2.70m girth No 455.60

B100024 Exceeding 2.70m and not exceeding 3.00m girth No 498.70

BW-B2
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B200000 EXCAVATION

Over site excavation

Excavating over site to reduce levels, getting out, removing,


depositing, spreading, levelling and mechanically ramming and
consolidating on site or removing off site to a dump as
directed by the SO or depositing at contractor's own dumping
ground

B200001 Average depth not exceeding 100 mm deep


m2 1.00
m2 1.23
B200002 Average depth exceeding 100 mm and not exceeding 200 mm
deep

B200003 Average depth exceeding 200 mm and not exceeding 300 mm m2 1.99
deep

B200004 Average depth exceeding 300 mm deep m3 6.13

m3 3.00
B200005 add for each additional 2.00m in depth beyond the first 1 .00m
deep

B200006 Add for excavating by hand for which mechanical means is not m2 1.20
possible for quantity which is less than 250 cu m in any single
operation or for any other reason the use of mechanical plant is
not possible for level n.e. 100mm deep

B200007 Add for excavating by hand for which mechanical means is not m2 1.50
possible for quantity which is less than 250 cu m in any single
operation or for any other reason the use of mechanical plant is
not possible for level n.e. 100mm deep & n.e. 200mm deep

B200008 Add for excavating by hand for which mechanical means is not m2 2.40
possible for quantity which is less than 250 cu m in any single
operation or for any other reason the use of mechanical plant is
not possible for level n.e. 200mm deep & n.e. 300mm deep

B200009 Add for excavating by hand for which mechanical means is not m2 8.40
possible for quantity which is less than 250 cu m in any single
operation or for any other reason the use of mechanical plant is
not possible for level n.e. 300mm deep & n.e. 1000mm deep

B200010 Excavate in slopes or embankment and get out, remove, deposit, m3 12.00
spread and level on site and / or remove to ENV's approved
dumping ground including trimming surfaces of slopes

B200011 Roll with power roller not exceeding one tonne or with approved hand m2 1.50
roller

BW-B3
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B200000 EXCAVATION (CONT'D)

Over site excavation (Cont'd)

B200012 Trim undulating ground to form level surface or embankments or m2 6.20


to required falls.

Trench excavation

Excavating foundation trenches commencing from reduced


level and getting out including timbering and strutting to sides
of excavation.

B200013 Not exceeding 2.00m deep


m3 15.00
B200014 Exceeding 2.00m and not exceeding 4.00m deep
m3 20.00
B20001 5 Exceeding 4.00m and not exceeding 6.00m deep
m3 31.50
B200016 Exceeding 6.00m and not exceeding 8.00m deep
m3 38.31
m3 30.00
B200017 Excavate to form trenches for drains, culverts retaining walls, etc.
not exceeding 2.00m deep and get out, part return, fill in and ram
and remainder remove and deposit, spread and level on site and /
or remove to ENV's dumping ground

B200018 Excavate to form trenches for drains, culverts retaining walls, etc. m3 35.00
exceeding 2.00m and not exceeding 4.00m deep and get out, part
return, fill in and ram and remainder remove and deposit, spread
and level on site and / or remove to ENV's dumping ground

B200019 Excavate to form trenches for drains, culverts retaining walls, etc. m3 47.00
exceeding 4.00m and not exceeding 6.00m deep and get out, part
return, fill in and ram and remainder remove and deposit, spread
and level on site and / or remove to ENV's dumping ground

B200020 Excavate to form trenches for drains, culverts retaining walls, etc. m3 53.31
exceeding 6.00m deep and get out, part return, fill in and ram and
remainder remove and deposit, spread and level on site and / or
remove to ENV's dumping ground

B200021 Excavate trenches for surface water channels and drains not m 45.10
exceeding 525mm width to an average depth not exceeding
750mm, get out, backfill, remove surplus excavated materials off
site and make good (length measured over sump pits)

BW-B4
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B200000 EXCAVATION (CONT'D)


Trench excavation (Cont'd)

Excavating trenches for service pipes, cables, kerbs and the


like and getting out, backfilling and removing surplus
excavated material off site

B200022 Not exceeding 600 mm wide and not exceeding 400 mm deep m 2.97

B200023 Exceeding 400 mm and not exceeding 600 mm deep m 4.51

B200024 Exceeding 600 mm and not exceeding 800 mm deep m 6.05

B200025 Exceeding 800 mm and not exceeding 1.00 m deep m 7.48

Pit excavation

Excavating pit for pile caps, pier holes, column or stanchion


bases and the like commencing from reduced level and
getting out including timbering and strutting to sides of
excavation.

B200026 Not exceeding 2.00m deep m3 27.00

B200027 Exceeding 2.00m and not exceeding 4.00m deep m3 37.80

B200028 Exceeding 4.00m and not exceeding 6.00m deep m3 48.60

B200029 Exceeding 6.00m deep and not exceeding 8.00m deep m3 59.40
B200030 No 21.60
Excavating isolated pier or post holes not exceeding 1 .00m3 and
getting out, backfilling and disposing of surplus excavated material
off site

B200031 Extra over excavation for excavating pier holes in hard ground No 41.04
(blasting will not be permitted. Work has to be carried out by
pneumatic tools, etc.)

Extra over all type of excavation and disposal for breaking up


and removing obstructions met in excavation

B200032 Brickwork and blockwork m3 9.72

B200033 Mass or reinforced concrete m3 72.90

B200034 Rock m3 80.14

BW-B5
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B200000 EXCAVATION (CONT'D)

Pit excavation (Cont'd)

Extra over all type of excavation and disposal for breaking up


and removing obstructions met in excavation (Cont'd)

B200035 Extra over trench excavations for breaking up rocks, reinforced m3 51.30
concrete, brickwork in excavation of hard standing or other
existing obstructions by blasting or other approved mechanical
means and cart away debris off site

B200036 Extra over for excavating trenches in semi-hard ground not


exceeding 2.00m deep m3 22.50

B200037 Extra over for excavating trenches in semi-hard ground exceeding


2.00m & not exceeding 4.00m deep m3 28.50

B200038 Extra over for excavating trenches in semi-hard ground exceeding


4.00m & not exceeding 6.00m deep m3 58.50

B200039 Extra over for excavating trenches in semi-hard ground exceeding


6.00m deep m3 73.50

B200040 Extra over for excavating pier holes in semi-hard ground


No 30.00

B200041 Extra over excavation for excavating trenches in hard ground not m3 28.50
exceeding 2.00m deep (blasting will not be permitted. Work has to
be carried out by pneumative tools etc.)

B200042 Extra over excavation for excavating trenches in hard ground


m3 36.10
exceeding 2.00m & not exceeding 4.00m deep (blasting will not be
permitted. Work has to be carried out by pneumative tools etc.)

B200043 Extra over excavation for excavating trenches in hard ground


exceeding 4.00m & not exceeding 6.00m deep (blasting will not be m3 74.10
permitted. Work has to be carried out by pneumative tools etc.)

B200044 Extra over excavation for excavating trenches in hard ground


exceeding 6.00m deep (blasting will not be permitted. Work has to m3 93.10
be carried out by pneumative tools etc.)

B200045 Breaking up brick paving, asphaltic concrete layer or stone road


base, tarmacadam paved road, carpark m3 13.90

BW-B6
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B200000 EXCAVATION (CONT'D)

Pit excavation (Cont'd)

Extra over all type of excavation and disposal for breaking up


and removing obstructions met in excavation (Cont'd)

B200046 Breaking up for brick paving, tarmacadam including granite base m2 17.80
course or other existing obstructions on the surface of the ground
not exceeding 300mm thick and removing debris off site

B200047 Breaking up for brick paving, tarmacadam including granite base m3 67.30
course or other existing obstructions on the surface of the ground
but exceeding 300mm thick and removing debris off site

B200048 Break up concrete bases (including excavation around base) not No 10.10
exceeding 0.10 m3 to posts, gate stops, etc. break up concrete,
remove debris off site and fill with earth to be obtained from
Contractor's own sources and make good

B200049 Break up concrete bases (including excavation around base) No 28.75


exceeding 0.10 m3 but not exceeding 0.30 m3 to posts, gate
stops, etc. break up concrete, remove debris off site and fill with
earth to be obtained from Contractor's own sources and make
good

Planking and strutting

B200050 Extra over various items of excavations for planking and strutting m2 11.47
left in as directed including cutting runners below ground level
(rates to include for wedges, cleats, etc)

B300000 FILLING

Backfilling around foundation, trenches, column bases, pile


caps, beams, pier holes and the like

B300001 Selected excavated material consolidated in layers obtained within m3 5.80


the site

B300002 Selected imported dry earth consolidated in layers obtained from m3 8.96
Contractor's own sources

B300003 Backfill and ram best of excavated material around foundations in m3 6.30
150mm layers

B300004 Selected excavated material consolidated in layers obtained within m3 6.85


the site

BW-B7
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B300000 FILLING (CONT'D)

Filling to make up levels, embankments or terraces by


deposi ting, spreading, levell ing, compacting a nd
consolidating in layers of 150mm thick

B300005 Selected imported dry earth consolidated in layers obtained from m3 9.84
Contractor's own sources
B300006 m3 6.30
Dry approved earth filling obtained from the Contractor's own
sources, deposited, spread and consolidated by hand or
mechanical means in layers of 300mm and as directed to make up
levels or banks

B300007 Dry approved earth filling obtained from the Contractor's own m3 6.70
sources, in filling to slipped banks including taking out loose,
muddy soil and all necessary hand or mechanical ramming as
directed

B400000 DISPOSAL OF EXCAVATED MATERIALS

Disposal on site (For Backfilling Purpose)


B400001 m3 3.73
Removing excavated material and depositing to a dump on site as
directed by the SO irrespective of distance

Disposal off site

B400002 Removing excavated material and disposal off site m3 6.05

B500000 SURFACE TREATMENT

Trimming

Trimming, levelling and grading excavated or make up level to


required cambers and gradients

B500001 Horizontal surfaces m2 0.86

B500002 Vertical surfaces m2 1.90

BW-B8
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B600000 HARDCORE AND BLINDING

Spreading, levelling, compacting, ramming and consolidating


or rolling with hand roller

B600001 Hardcore as specified by the S.O. in beds, making up levels, etc m3 43.34
and deposited, spread, levelled mechanically consolidated (in
layers of 300 mm thick if exceeding 300 mm thick) including
blinding with sand/granite dust

B600002 Quarry dust in beds, f illings, etc irrespective of thickness m3 29.77


deposited, spread, levelled and rammed with mechanical hammer
or rolled with hand roller

B600003 Granite aggregate of minimum size 60 mm in beds, fillings, etc m3 72.20


irrespective of thickness deposited, spread, levelled and rammed
with mechanical rammer or rolled with hand roller

B600004 40mm granite aggregate in beds, filling etc. irrespective of m3 71.40


thickness, deposited, spread, levelled and rammed with
mechanical rammer, or rolled with hand roller

B600005 20mm granite aggregate in beds, filling etc. irrespective of m3 70.30


thickness, deposited, spread, levelled and rammed with
mechanical rammer, or rolled with hand roller

B600006 12mm granite aggregate in beds, filling etc. irrespective of m3 68.70


thickness, deposited, spread, levelled and rammed with
mechanical rammer, or rolled with hand roller

B600007 3 mm to 6 mm granite chippings in beds, filling, etc irrespective of m3 49.23


thickness deposited, spread, levelling and rammed with
mechanical hammer or rolled with hand roller

B600008 Unwashed sand in bed, filling, etc irrespective of thickness m3 32.22

B700000 SUNDRIES

B700001 Approved used sawn timber irrespective of sizes, for needling, m2 49.20
strutting or shoring, including all hoop-iron (to be left in excavation)

B700002 Approved used sawn timber for protective timber hoarding m 217.50
including erecting and dismantling after use (where specially
ordered, not related to the work and for protective timber hoarding
required to be left in)

BW-B9
B : EXCAVATION

ITEM NO. DESCRIPTION UNIT RATE


(S$)

B700000 SUNDRIES (CONT'D)

B700003 Approved used sawn timber for protective timber hoarding m 133.10
including erecting and dismantling after use BCD drawing. Type
B(75) (where specially ordered, not related to the work and for
protective timber hoarding required to be left in)

B700004 Approved used sawn timber for protective timber hoarding m 236.70
including erecting and dismantling after use BCD drawing. Type
C(75) (where specially ordered, not related to the work and for
protective timber hoarding required to be left in)

BW-B10
SECTION C: CONCRETE WORK
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C100000 SCUPPER DRAINS

Scupper drains and channels formed in existing concrete


slabs; made to correct line and falls and form rebate to
receive grating if any; rendering invert and sides with 15mm
thick cement and sand (1:3) rendering; with and including
diamond cutting / breaking existing concrete slabs; providing
extra concrete of similar grade to floor below scupper drains
and channels; all necessary formwork; clearing debris off site
and making good work disturbed.

C100001 100mm Wide

m 26.38
C100002 150mm Wide
m 28.40
C100003 125mm Wide
m 29.00
C100004 250mm Wide
m 34.00

Scupper drains and channels formed in new concrete slabs;


made to correct line and falls and form rebate to receive
grating if any; rendering invert and sides with 15mm thick
cement and sand (1:3) rendering

C100005 100mm wide


m 12.64
C100006 150mm wide m 13.61

Breaking up existing concrete structure including cutting and


bending reinforcement and removing debris off site

C100007 Breaking up existing scupper drains and channels


m 10.21
C100008 Removing existing fillings in groove not exceeding 50mm x 50mm m 4.21
deep, cleaning and preparing to receive new work

BW-C1
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C200000 CONCRETE WORK

C200001 Mass or lightly reinforced (ie one layer of mesh reinforcement) m3 107.80
concrete work such as walls, slabs, aprons, steps, cooking bases,
curbs etc removing debris off site and making good works
disturbed to match with existing OR breaking up the concrete into
smaller pieces to form hardcore bed, cutting and removing
reinforcement where necessary, providing sand or granite dust top
blinding, levelling and mechanically consolidating, removing debris
off site and making good works disturbed

C200002 Cutting of concrete pavement using powered diamond cutter to m 5.83


achieve a straight edge up to 150mm deep

C200003 Break up reinforced concrete columns, suspended beams, walls, m3 130.00


slabs and canopies, etc. including cutting reinforcement and
removing debris off site and making good works disturbed to
match with existing

Labour in cutting reinforced concrete; including cutting and


bending reinforcement; 15mm cement and sand (1:3)
rendering and removing debris off site

C200004 Forming V grooves


m 3.89
m 6.30
C200005 Forming grooves not exceeding 100mm wide and not exceeding
50mm deep

C200006 Forming grooves not exceeding 100mm wide and exceeding m 6.30
50mm and not exceeding 100mm deep

C200007 Forming 75 x 75mm rebates m 8.42

m 3.89
C200008 Cutting out cracks to a width of at least 15mm or form undercut
edges

C200009 Cut groove not exceeding 75mm wide x 75mm deep in concrete m 4.20
and render with 15mm thick cement mortar (1:3)

C200010 Supply and fix calibrated "tell-tale" glass to existing cracks on No. 50.00
plastered walls, etc

Cutting through reinforced concrete floors or walls to form


openings; cutting reinforcement, removing debris off site and
making good work disturbed

BW-C2
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C200000 CONCRETE WORK (CONT'D)

Cutting through reinforced concrete floors or walls to form


openings; cutting reinforcement, removing debris off site and
making good work disturbed

C200012 Exceeding 0.02 m3 and not exceeding 0.05 m3 No 24.08

C200013 Exceeding 0.05 m3 and not exceeding 0.10 m3 No 50.80

Cutting through reinforced concrete floors or walls to form


openings; cutting reinforcement, removing debris off site and
making good work disturbed (Cont'd)

C200014 Exceeding 0.10 m3 and not exceeding 0.20 m3 No 80.87

C200015 Exceeding 0.20 m3 No 159.20

Patch up openings for pipes/conduits with waterproof cement


and sand (1:3) mortar in walls/floors; including making good
to match existing / surrounds

C200016 Not exceeding 100mm diameter openings and not exceeding No 6.83
225mm thick walls/floors
C200017 No 9.90
Not exceeding 100mm diameter openings and exceeding 225mm
thick walls/floors
C200018 No 11.19
Exceeding 100mm diameter openings and not exceeding 225mm
thick walls/floors

C200019 Exceeding 100mm diameter openings and exceeding 225mm thick No 15.13
walls/floors

BW-C3
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C300000 REPAIR TO CONCRETE

Cutting out cracks to form V-shape grooves, cleaning and


p r e pa r i n g s u r fa c e s or a n y o t h e r m e th o d o f s u r fa c e
preparation as recommended by the grouting specialist and
pressure grouting the cracks w ith approved grouting
materials of sufficient adhesive, compressive and tensile
strength including provision for mobilisation, grout pipes,
fine wiremesh, pressure grouting pumps, tools, all
accessories, scaffolding (Refer to Specification and
Preambles) and hacking and making good plastered or tiled
finish if any. Applying tw o coats of water and w eather
resistance protective/decorative coatings as carbonation
barrier all in accordance to grouting specialist's
recommendation

Non-shrink cementitious grouting (minimum two (2) metres


total length within the building and per call)

C300001 To concrete floor, vertical sides of columns, beams and the like m 58.00

C300002 To concrete soffits of slabs, canopy, beams and the like m 65.80

C300003 To brick substrates m 44.80

Epoxy resin grouting (minimum two (2) metres total length


within the building and per call)

C300004 To concrete floor, vertical sides of columns, beams and the like m 77.00

C300005 To concrete soffits of slabs, canopy, beams and the like m 88.00
C300006 Epoxy resin grouting around floor trap, rainwater down pipe, water No. 100.00
pipe for various sizes (rate for maximum of two (2) groute points)

C300007 "Flexin" resin grouting (minimum one (1) metre total length within m 130.00
the building and per call)

Polyurethane water cut-off (minimum two (2) metres total


length within the building and per call)

C300008 To concrete floor, vertical sides of columns, beams and the like m 104.50

C300009 To concrete soffits of slabs, canopy, beams and the like m 110.00

BW-C4
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C300000 REPAIR TO CONCRETE (CONT'D)

Cutting out cracks to form V-shape grooves, cleaning and


preparing surfaces and patching up the cracks with approved
mortar of sufficient adhesive, compressive and tensile
strength including provision for mobilisation, grout pipes,
fin e wir emesh , pr essur e gr ou tin g p u mp s, to ol s, all
accessories, scaffolding and hacking and making good
plastered or tiled finishes if any. Applying two coats of water
and weather resistance protective/decorative coating as
carbonation barrier all in accordance to grouting specialist's
recommendation (Refer to Specification and Preambles)

Non-shrink cementitious mortar

C30001 0 To concrete surfaces


m 31.46
m 24.20
C30001 1 To brick substrates

Repairs to water leakage

Inject polyurethane water cut-off to leakage

C30001 2 To concrete soffits of slabs; area not exceeding 500mm x 500mm No 272.80

C300013 To pipe area (any size) No 206.80

C300014 Rectifying water leakage using "shutout" material and patching No 173.90
with epoxy mortar on soffit of reinforced concrete slabs, area not
exceeding 500 mm x 500 mm

BW-C5
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C300000 REPAIR TO CONCRETE (CONT'D)

Hacking off spalling or loose concrete in patches until rusty


reinforcement and good concrete is reached. Thoroughly
brush rusty reinforcement to remove rust and scale, cleaning
all surfaces of concrete and reinforcement by using wire brush
and compressed air or chemicals. Prime all exposed
reinforcement with approved rust and corrosion inhibitive
primer. Applying a layer of approved bonding agent to
concrete and reinforcement. Construct formwork and props
if necessary and repairing up with approved grouting
materials with sufficient adhesive, compressive and tensile
strength including provision for mobilization, grout pipes,
fine wire mesh, pressure grouting pumps, tools, all accessories,
scaffolding and hacking and making good plastered or tiled
finishes if any all in accordance to grouting specialist's
recommendation. Removing formwork including props if any
(minimum half (1/2) m2 within the complex and per call) (Refer
to Specification and Preambles)

Non-shrink cementitious grouting

C30001 5 To concrete floor, vertical sides of columns, beams and the like m2 298.50

C30001 6 To concrete soffits of slabs, canopy, beams and the like m2 418.00

Epoxy resin grouting

C30001 7 To concrete floor, vertical sides of columns, beams and the like m2 507.50

C30001 8 To concrete soffits of slabs, canopy, beams and the like m2 746.50
Note:

The rates given above exclude replacement of reinforcement.


If the cross-sectional area of reinforcement bar is reduced by
more than 15% or as recommended by the SO, additional
reinforcement bar with proper lapping must be added to the
approval of the SO and the grouting specialist. Extra charge
over the abovementioned rates shall be paid if replacement or
additional reinforcement bar are carried out in accordance with
the rates for reinforcement bars in this Schedule of Rates

BW-C6
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C300000 REPAIR TO CONCRETE (CONT'D)

Hacking off spalling or loose concrete in patches until rusty


reinforcement and good concrete is reached. Thoroughly
brush rusty reinforcement to remove rust and scale, cleaning
all surfaces of concrete and reinforcement by using wire brush
and compressed air or chemicals. Priming all exposed
reinforcement with approved rust and corrosion inhibitive
primer. Applying a layer of approved bonding agent to
concrete and reinforcement and patch up surfaces with
approved mortar of sufficient adhesive, compressive and
tensile strength including provision for mobilization, fine wire
mesh, making good affected surfaces, with matching
materials, formworks, props, etc. all in accordance to
manufacturer's instruction. Thickness of spalling or loose
concrete not exceeding 30mm thick. (Refer to Specification
and Preambles)

Non-shrink cementitious mortar (minimum one (1) m2 within


the building per call)

C300019 Vertical surfaces of columns, walls and the like m2 196.50

C300020 Non -shrink cementitious mortar to soffit of concrete slabs, m2 223.90


canopies, beams and the like (minimum one (1) m2 within the
building per call)

C400000 IN-SITU CONCRETE

In-situ concrete kerbs irrespective of size in existing works


finished fair on all exposed surfaces including formwork,
angles, ends and intersections, hacking, jointing to existing
and removing debris off site per 1000mm2

C400001 Grade 20 (rate is every 1000mm2 in sectional area e.g. 75 x m 0.77


100mm kerbs = 7500mm2 in section. Therefore rate is $5.25 per
linear metre (7500 x 0.70 divided by 1000)

C400002 Grade 25
m 0.86
C400003 Grade 30 m 0.97

m 3.75
C400004 Concrete (Grade 25) in curbs etc. irrespective of size in new or
existing work including hacking, formwork, angles, ends,
intersections, jointing to existing and removing debris per 1,000 sq.
mm sectional area. Rate is for every 1,000 sq. mm in sectional

BW-C7
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C400000 IN-SITU CONCRETE (CONT'D)

In-situ concrete kerbs irrespective of size in existing works


finished fair on all exposed surfaces including formwork,
angles, ends and intersections, hacking, jointing to existing
and removing debris off site per 1000mm2 (Cont'd)

C400005 Concrete (Grade 25) in curbs rendered on both sides and top with m 6.00
15mm cement and sand rendering, (irrespective of size) in new or
existing work including hacking, formwork, angles, ends,
intersections, jointing to existing and removing debris per 1,000 sq

Plain concrete complying with BS 8110; in bed, fillings, under


blinding, foundations, column bases, ground slabs, beams,
etc irrespective of thickness

C400006 Grade 10 m3 144.63

C400007 Grade 15 m3 147.70

C400008 Grade 20 m3 151.70


C400009 Grade 20 in isolated pier or post foundations 0.50m3 or less No 112.49
including any extra excavation, disposal and formwork

C500000 REINFORCED CONCRETE

Reinforced concrete complying with BS 8110; in foundation,


beds, slabs, beams, columns, staircases, retaining walls, etc
irrespective of sizes or thickness including working around
rod or fabric reinforcement, steel beams, stanchion, etc

C500001 Grade 20 m3 156.23

C500002 Grade 25 m3 159.80

C500003 Grade 30 m3 165.68

C500004 Grade 35 m3 168.00

C500005 Grade 40 m3 174.83

C500006 Grade 45 m3 176.42

BW-C8
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C500000 REINFORCED CONCRETE (CONT'D)

Reinforced concrete complying with BS 8110; in foundation,


beds, slabs, beams, columns, staircases, retaining walls, etc
irrespective of sizes or thickness including working around
rod or fabric reinforcement, steel beams, stanchion, etc
(Cont'd)

C500007 Waterproofing to concrete with approved waterproofing admixtures m3 25.00


or additives mixed in accordance with the manufacturer's
specification and recommendations

C500008 Concrete grade 25 as specified in foundations each not exceeding No 15.00


0.07m3 including all necessary formwork, excavation, removing
surplus excavated material off site and backfilling

C500009 Concrete grade 25 as specified in foundations each exceeding No 33.00


0.07m3 and not exceeding 0.15m3 including all necessary
formwork, excavation, removing surplus excavated material off
site and backfilling

C500010 Ready-mix concrete, grade 10 as specified in foundations, beds, m3 135.00


slabs, beams, columns, staircases, retaining walls, etc.
irrespective of sizes or thickness including working around rod or
fabric reinforcement, steel beams, stanchions etc

C50001 1 Ready-mix concrete, grade 20 as specified in foundations, beds, m3 150.00


slabs, beams, columns, staircases, retaining walls, etc.
irrespective of sizes or thickness including working around rod or
fabric reinforcement, steel beams, stanchions etc

C500012 Ready-mix concrete, grade 25 as specified in foundations, beds, m3 155.00


slabs, beams, columns, staircases, retaining walls, etc.
irrespective of sizes or thickness including working around rod or
fabric reinforcement, steel beams, stanchions etc

C500013 Ready-mix concrete, grade 30 as specified in foundations, beds, m3 165.00


slabs, beams, columns, staircases, retaining walls, etc.
irrespective of sizes or thickness including working around rod or
fabric reinforcement, steel beams, stanchions etc

C500014 Ready-mix concrete, grade 35 as specified in foundations, beds, m3 170.00


slabs, beams, columns, staircases, retaining walls, etc.
irrespective of sizes or thickness including working around rod or
fabric reinforcement, steel beams, stanchions etc

C500015 Ready-mix concrete, grade 40 as specified in foundations, beds, m3 180.00


slabs, beams, columns, staircases, retaining walls, etc.
irrespective of sizes or thickness including working around rod or
fabric reinforcement, steel beams, stanchions etc

BW-C9
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C500000 REINFORCED CONCRETE (CONT'D)

Reinforced concrete complying with BS 8110; in foundation,


beds, slabs, beams, columns, staircases, retaining walls, etc
irrespective of sizes or thickness including working around
rod or fabric reinforcement, steel beams, stanchion, etc
(Cont'd)

C500016 Waterproofed concrete complying with BS 8110 with approved m3 170.00


waterproofing compound G30

C500017 Waterproofed concrete complying with BS 8110 with approved m3 180.00


waterproofing compound G35

C500018 Sulphate resisting to concrete with approved sulphate resisting m3 55.94


admixtures mixed in accordance with the manufacturer's
specification and recommendations

C500019 Type S1 scupper drain and pipe laid to even falls and jointed i n m 26.10
cement and sand (1:3) mortar

C500020 Scupper drain and 230mm diameter concrete pipe laid to even m 24.00
falls and jointed in cement and sand (1:3) mortar

C500021 Scupper drain and 300mm diameter concrete pipe laid to even m 30.00
falls and jointed in cement and sand (1:3) mortar

C500022 Scupper drain and 250mm diameter class "AW" heavy duty PVC 48.00
m
pipe laid to even falls and jointed in cement and sand (1:3) mortar

C500023 Precast concrete (Grade 20) lintel finished fair on all exposed m 13.10
surfaces, size 115 x 150mm high and reinforced with one 10mm
diameter mild steel bar

C500024 Precast concrete (Grade 20) lintel finished fair on all exposed m 16.80
surfaces, size 115 x 225mm high and reinforced with one 3mm
diameter mild steel bar

C500025 Precast concrete (Grade 20) lintel finished f air on all exposed m 20.40
surfaces, size 225 x 150mm high and reinforced with two 10mm
diameter mild steel bar

C500026 Precast concrete (Grade 20) lintel finished fair on all exposed m 25.10
surfaces, size 225 x 225mm high and reinforced with two 13mm
diameter mild steel bar

BW-C10
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C600000 LABOURS AND SUNDRIES ON CONCRETE

Surface finishes
C600001 m2 2.50
Labour for steel trowelling top surface of concrete to a smooth
finish and finished to falls and currents or cambers including
addition cement required

C600002 m2 2.00
Labour for wood floating top surface of concrete to a wood float
finish and finished to falls and currents or cambers including
addition cement required

Expansion joints

Compressible non-extruding bitumen impregnated fibreboard


to joint including all necessary formwork

C600003 10mm thick m2 33.48

C600004 12mm thick m2 36.83

C600005 20mm thick m2 50.22

C600006 25mm thick m2 58.00


C600007 m 1.50
Supply and fix bitumen impregnated fibre board expansion joint
filler to 10mm thick x 75mm high joints

C600008 m 1.60
Supply and fix bitumen impregnated fibre board expansion joint
filler to 13mm thick x 75mm high joints
C600009 m 2.70
Supply and fix bitumen impregnated fibre board expansion joint
filler to 20mm thick x 75mm high joints
C600010 m 3.00
Supply and fix bitumen impregnated fibre board expansion joint
filler to 25mm thick x 75mm high joints

C60001 1 Add/Deduct for every stage of 25mm in width for 10mm thick m 0.50

C600012 Add/Deduct for every stage of 25mm in width for 13mm thick m 0.60

C600013 Add/Deduct for every stage of 25mm in width for 20mm thick m 0.90

C600014 Add/Deduct for every stage of 25mm in width for 25mm thick m 1.00

BW-C11
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C600000 LABOURS AND SUNDRIES ON CONCRETE (CONT'D)

Closed cell expanded polyethylene filler board to joint


including all necessary formwork

C600015 12mm thick m2 100.15

C600016 20mm thick m2 113.30

C600017 25mm thick m2 154.25


C600018 No 0.30
6mm diameter x 450mm long mild steel bonding tie with one end
cast into concrete and hooked around reinforcement and joints of
brickwork including forming perforations in formwork

Closed cell expanded polyethylene foam in circular section


cords as bond breaking strip fixed into joints

C600019 10mm diameter m 1.50

C600020 12mm diameter m 2.00

C600021 15mm diameter m 2.50

C600022 25mm diameter m 2.80

Polysulphide sealers squeezed into joints

C600023 25 x 15mm deep m 11.40

C600024 25 x 25mm deep m 18.30

C600025 50 x 15mm deep m 29.50

Silicone sealers squeezed into joints

C600026 25 x 15mm deep m 8.75

C600027 25 x 25mm deep m 14.23


C600028 m 2.30
Supply and apply silicone sealants to 6mm x 6mm joints without
foam rod all to manufacturer's instructions
C600029 4.60
Supply and apply silicone sealants to 8mm x 8mm joints without m
foam rod all to manufacturer's instructions

BW-C12
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C600000 LABOURS AND SUNDRIES ON CONCRETE (CONT'D)

Silicone sealers squeezed into joints (Cont'd)

C600030 Supply and apply silicone sealants to 25mm x 15mm joints without m
foam rod all to manufacturer's instructions
6.60
C600031 Supply and apply silicone sealants to 25mm x 25mm joints without
foam rod all to manufacturer's instructions

Polyurethane based elastic sealers squeezed into joints

C600032 25 x 15mm deep m 13.62

C600033 25 x 25mm deep m 22.70

C600034 50 x 25mm deep m 42.90

C600035 100 x 15mm deep m 52.50

Hot bitumen or mastic fillings in groove to form expansion


joints and filling with weak cement mortar where necessary

C600036 15 x 25mm deep m 4.00

C600037 Add or deduct to/from above item for every 15mm in depth m 1.00

Waterstops

PVC double bulb waterstops cast into concrete including all


necessary formwork

23.00
C600038 200mm wide m

26.91
C600039 230mm wide m

22.10
C600040 150mm wide m
C600041 m 23.00
Supply and fix 200mm wide UPVC water stop embedded in
concrete
C600042 m
Supply and fix 230mm wide UPVC water stop embedded in 26.00
concrete

BW-C13
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C600000 LABOURS AND SUNDRIES ON CONCRETE (CONT'D)

Waterproofing membrane system

C600043 50mm Cement and sand (1:3) protective screed m2 12.31


C600044 m2 5.72
25mm thick polystyrene board (16kg/m3 density) laid loose as
protective board
C600045 m2 22.36
Single layer self adhesive bitumen membrane 1.5 to 1.8mm with
welded seams

Damp proof membrane laid to underside of concrete structure;


lapped 150mm at joints (measured n et t - no allowance made
for laps)

C600046 0.60mm thick polyethylene moisture barrier m2 6.91

C600047 0.80mm thick polyethylene moisture barrier m2 11.12

C600048 Medium duty (289g/m2 weight) building paper m2 2.27

C600049 Medium duty (527g/m2 weight) building paper m2 4.21

Firestop sealing compound

C600050 Firestop sealing compound in fillings irrespective of thickness m3 2,185.00


C600051 m 37.50
Supply and fix 150mm width Combiflex Hypalon sealing strip,
1.5mm thick, including preparation of surface and adhesive, or
equivalent to construction joints

C600052 m 50.10
Supply and fix 200mm width Combiflex Hypalon sealing strip,
1.5mm thick, including preparation of surface and adhesive, or
equivalent to construction joints

C600053 m 75.00
Supply and fix 300mm width Combiflex Hypalon sealing strip,
1.5mm thick, including preparation of surface and adhesive, or
equivalent to construction joints

C600054 m 47.60
Supply and fix 150mm width Combiflex Hypalon sealing strip,
2.00mm thick, including preparation of surface and adhesive, or
equivalent to construction joints

equivalent to construction
C600055 joints
Supply and fix 200mm width Combiflex Hypalon sealing strip,
2.00mm thick, including preparation of surface and adhesive, or
BW-C14
C : CONCRETE WORK
m

60.00

BW-C15
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C600000 LABOURS AND SUNDRIES ON CONCRETE (CONT'D)

Firestop sealing compound (Cont'd)

C600056 m 85.00
Supply and fix 300mm width Combiflex Hypalon sealing strip,
2.00mm thick, including preparation of surface and adhesive, or
equivalent to construction joints

Diamond coring through reinforced concrete to form holes;


including mobilisation and necessary equipment

Note :
A minimum charge of $180.00 for total coring works value
below $180.00 would be applied as the total cost

C600057 25mm diameter, not exceeding 50mm diameter 10mm 2.94

C600058 50mm diameter, not exceeding 75mm diameter 10mm 3.03

C600059 75mm diameter, not exceeding 100mm diameter 10mm 3.88

C600060 100mm diameter, not exceeding 125mm diameter 10mm 4.84

C600061 125mm diameter, not exceeding 150mm diameter 10mm 6.25

C600062 150mm diameter, not exceeding 175mm diameter 10mm 7.33

C600063 175mm diameter, not exceeding 200mm diameter 10mm 9.66

C600064 200mm diameter, not exceeding 225mm diameter 10mm 11.36

C600065 225mm diameter, not exceeding 250mm diameter 10mm 13.65

C600066 250mm diameter, not exceeding 275mm diameter 10mm 18.30

C600067 275mm diameter, not exceeding 300mm diameter 10mm 19.80

C600068 Exceeding 300mm diameter 10mm 21.30

C600069 150mm high No 5.50

C600070 Precast concrete Grade 20 heelstone 150mm high to suit section No. 7.00
of door frame and including 13mm diameter mild steel dowel
100mm long

C600071 Precast concrete Grade 25 heelstone 150mm high to suit section No. 7.00
of door frame and including 13mm diameter mild steel dowel
100mm long

BW-C16
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C600000 LABOURS AND SUNDRIES ON CONCRETE (CONT'D)

Plain concrete (Grade 20) heelstones to suit door section of


door frame with and including 13mm diameter mild steel
dowels 100mm long

C600072 One layer of heavy duty (Basis weight : 527 g/m2) approved m2 5.25
building paper laid under concrete slab and lapped 150mm at
joints (Measured nett No allowance made for laps)

C600073 Concrete (Grade 20) heelstone cast to suit section of door frame No. 10.50
including one 100 x 13mm diameter mild steel dowel and 150mm
high

C700000 REINFORCEMENT

Mild steel rod reinforcement complying with SS 18; in


foundations, beams, slabs, stairs, canopies, etc including all
labour forming stirrups, links, spacer blocks etc

C700001 6 mm diameter
kg 1.38

C700002 10mm diameter kg 1.27

C700003 13mm diameter kg 1.27


kg 1.50

C700004 6mm to 16mm diameter mild steel rods in foundations, beams,


slabs, stairs, canopies, etc invluding all labour forming stirrup,
links, spacer blocks etc to comply with SS18
kg 1.40
C700005 Over 16mm diameter mild steel rods in foundations, beams, slabs,
stairs, canopies, etc invluding all labour forming stirrup, links,
spacer blocks etc to comply with SS18

High tensile deformed steel bar reinforcement complying with


SS 18; in foundations, beams, slabs, stairs, canopies, etc
including all labour forming stirrups, links, spacer blocks etc

C7 0 0 0 0 6 1 0 m m d i a me t e r
kg 1.30
C700007 13mm to 32mm diameter kg 1.30

kg 1.30
C700008 40mm diameter

BW-C17
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C700000 REINFORCEMENT

High tensile deformed steel bar reinforcement complying with


SS 18; in foundations, beams, slabs, stairs, canopies, etc
including all labour forming stirrups, links, spacer blocks etc
(Cont'd)

C700009 9mm to 16mm diameter deformed high tensile steel rod in kg 1.50
foundations, beams, slabs, stairs, canopies, etc including all labour
forming stirrups, links, spacer blcoks etc to comply with SS2

C700010 20mm to 25mm diameter deformed high tensile steel rod in kg 1.40
foundations, beams, slabs, stairs, canopies, etc including all labour
forming stirrups, links, spacer blcoks etc to comply with SS2

C70001 1 Over 28mm diameter deformed high tensile steel rod in kg 1.50
foundations, beams, slabs, stairs, canopies, etc including all labour
forming stirrups, links, spacer blcoks etc to comply with SS2

Welded steel fabric reinforcement complying with SS 32; well


lapped at joints (measured nett - no allowance made for laps)

C70001 2 Reference No A5 weighing 1.54 kg/m2 m2 3.03

C700013 Reference No A6 weighing 2.22 kg/m2 m2 4.20

C700014 Reference No A7 weighing 3.02 kg/m2 m2 5.13

C700015 Reference No A8 weighing 3.95 kg/m2 m2 6.52

C700016 Reference No A9 weighing 4.99 kg/m2 m2 3.58

C700017 Reference No A10 weighing 6.16 kg/m2 m2 9.97

C70001 8 Reference No A1 1 weighing 7.46 kg/m2 m2 11.99

C700019 Reference No A12 weighing 8.89 kg/m2 m2 16.20

C700020 Reference No A13 weighing 10.42 kg/m2 m2 18.00

C700021 Reference No B5 weighing 3.05 kg/m2 m2 6.26

C700022 Reference No B6 weighing 3.73 kg/m2 m2 6.49

BW-C18
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C700000 REINFORCEMENT (CONT'D)

Welded steel fabric reinforcement complying with SS 32; well


lapped at joints (measured nett - no allowance made for laps)
(Cont'd)

C700023 Reference No B7 weighing 4.53 kg/m2 m2 7.41

C700024 Reference No B8 weighing 5.93 kg/m2 m2 9.62

C700025 Reference No B9 weighing 6.97 kg/m2 m2 11.23

C700026 Reference No B10 weighing 8.14 kg/m2 m2 13.01

C700027 Reference No B1 1 weighing 9.43 kg/m2 m2 14.80

C700028 Reference No B12 weighing 10.90 kg/m2 m2 16.85

C700029 Reference No B13 weighing 13.50 kg/m2 m2 20.63

C700030 100 x 400mm x 2.61 kg/m2 approved fabric reinforcement to SS m2 4.94


32:1986 well lapped and tied at joints

C700031 100 x 400mm x 3.41 kg/m2 approved fabric reinforcement to SS m2 6.01


32:1986 well lapped and tied at joints

C700032 100 x 400mm x 4.34kg/m2 approved fabric reinforcement to SS m2 7.20


32:1986 well lapped and tied at joints

C700033 100 x 400mm x 5.55kg/m2 approved fabric reinforcement to SS m2 8.91


32:1986 well lapped and tied at joints

C700034 100 x 400mm x 6.72kg/m2 approved fabric reinforcement to SS m2 10.29


32:1986 well lapped and tied at joints

C700035 100 x 400mm x 8.44kg/m2 approved fabric reinforcement to SS m2 12.00


32:1986 well lapped and tied at joints

C700036 100 x 400mm x 9.87kg/m2 approved fabric reinforcement to SS m2 14.00


32:1986 well lapped and tied at joints

C700037 Reference No D4 weighing 1.98 kg/m2 m2 5.10

C700038 Reference No D5 weighing 3.08 kg/m2 m2 6.26

C700039 Reference No D6 weighing 4.44 kg/m2 m2 7.66

BW-C19
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C700000 REINFORCEMENT (CONT'D)

Welded steel fabric reinforcement complying with SS 32; well


lapped at joints (measured nett - no allowance made for laps)
(Cont'd)

C700040 Reference No D7 weighing 6.04 kg/m2 m2 9.82

C700041 Reference No D8 weighing 7.90 kg/m2 m2 12.71

C700042 Reference No D9 weighing 9.98 kg/m2 m2 15.55

C700043 Reference No D10 weighing 12.32 kg/m2 m2 18.90

C700044 Reference No D11 weighing 14.92 kg/m2 m2 22.68

C700045 Reference No D12 weighing 17.76 kg/m2 m2 26.78

C700046 Reference No D13 weighing 20.84 kg/m2 m2 31.21

C700047 Reference No E8 weighing 5.27 kg/m2 m2 8.86

C700048 Reference No E9 weighing 6.67 kg/m2 m2 10.80

C700049 Reference No E10 weighing 8.23 kg/m2 m2 13.07

C700050 Reference No E1 1 weighing 9.95 kg/m2 m2 15.55

C700051 Reference No E1 2 weighing 11.84 kg/m2 m2 18.25


C700052 Reference No E13 weighing 13.89 kg/m2 m2 21.17

C800000 PRESTRESSING IN-SITU CONCRETE

Prestressing including tendons, tendon ducts, anchorages,


tensioning, grouting, etc

C800001 10mm to 16mm diameter kg 3.46

BW-C20
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C900000 FORMWORK

Formwork to in-situ concrete including strutting not


exceeding 3.50m high

C900001 Flat/slope/vertical surfaces m2 24.28


C900002 m2 25.99
Flat/slope/vertical surfaces to produce true and even concrete
faces

C900003 Curved/circular surfaces m2 27.38


C900004 Curved/circular surfaces to produce true and even concrete faces m2 30.64

C900005 Extra over items (C900001) to (C900004) above for every m2 2.33
additional stage of 1 .50m for propping and strutting exceeding
3.50m high

C1000000 PERMANENT METAL FORMWORK

Galvanised steel permanent formwork welded to structural


steelworks at supports

C1000001 0.75mm thick m2 36.80

C1000002 1.00mm thick m2 45.40

1.00mm Galvanised edge form

C1000003 Not exceeding 100mm girth m 6.60

C1000004 Exceeding 100mm and not exceeding 200mm girth m 10.80

C1000005 Exceeding 200mm and not exceeding 300mm girth m 13.20

C1000006 M16 x 75mm shear stud by arc welding No 4.31

BW-C21
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C1100000 PRECAST CONCRETE

Precast concrete framed structure members (Grade 50)


include concrete, reinforcement, formwork; including the
formation and filling of holes, chases and recesses for
anchors, bolts and the like; grouting, pointing of joints,
neoprene, surface finishes, delivery, unloading, hoisting,
erecting, fixing including all necessary temporary erection
gear, bracing and working platform to the bearing levels and
positions

Precast hollow core floor slabs 1200m wide together with


polystyrene void filler, neoprene, etc

C1100001 215mm thick m2 58.43

C1100002 265mm thick m2 62.10

C1100003 300mm thick m2 69.55

C1100004 325mm thick m2 77.00

C1100005 360mm thick m2 84.46

C1100006 380mm thick m2 91.91

C1100007 400mm thick m2 100.66

C1100008 420mm thick m2 107.24

Precast columns

C1100009 Columns irrespective of size and height m3 1,095.20

Precast beams

C11 00010 Beams irrespective of size and height m3 980.64

BW-C21
C : CONCRETE WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

C1100000 PRECAST CONCRETE (CONT'D)

Precast concrete (grade 20) including reinforcement and


formwork in new or existing work with all exposed faces
finished fair, bedding, jointing and pointing in cement mortar
(1:3) or with edges bedding and pointing in putty or mastic
including making good, removing debris off site, all
necessary moulds, transporting, handling and fixing

C1100011 In posts, bollards, blocks, lintels, copings, sills, steps, strings, m3


railings etc irrespective of size including hoisting and fixing to the
bearing levels up to 3.00 m above ground level 702.00

C11 00012 Extra over item (C1 100011) above for each additional 1 .50m
height of hoisting
m3

BW-C22
SECTION D: BRICKWORK & BLOCKWORK
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D100000 HACKING / DEMOLITION

D100001 Hacking off existing brickwork or blockwork including removal of


m2 4.86
debris off site and good bricks set aside for re-use and including all
necessary minor shoring

D100002 Carefully remove existing glass blocks (any size) from 80mm or
100mm thick walls, vents, etc clearing off site or stack good blocks m2 8.60
aside for re-use and removing debris off site

D100003 Hacking off existing granite rubble walls, clearing off site or stack good
m3 102.40
blocks aside for re-use and removing debris off site

D100004 Taking from stack and rebuilt granite random rubble walls in m3 165.60
cement mortar (1:3) with joints raking out and pointing in plain or
white cement as the work proceeds

D100005 Taking from stack and rebuilt glass block walls in cement mortar m2 27.97
(1:6) and pointing in tinted cement as the work proceeds

D100006 Replacing all broken and missing brick -on-edge in steps, sills, m2 35.80
copings and the like with new one in cement mortar (1:3) to match
existing

D100007 Hack off existing brickwork and/or blockwork, clear of site and m3 92.10
stack good bricks aside for re-use and including all necessary
minor shoring

Labour and material in cutting existing brickwork and


blockwork to form groove not exceeding 100mm wide
including removal of debris off site and making good to match
existing

D100008 Not exceeding 50mm deep


m 4.10
D100009 Exceeding 50mm and not exceeding 100mm deep
m 4.64

D100010 Small openings (i.e. not exceeding 0.50 m2 in brickwork or No 15.00


blockwork and not exceeding 150mm thick (total thickness)

D100011 Add for each additional stage of 25mm thick walls, floors, etc for
No 2.50
above item (D100010)

D100012 Large openings (i.e. exceeding 0.50 m2 and not exceeding 2 m2)
in brickwork or blockwork and not exceeding 150mm thick (total No 48.40
thickness)

BW-D1
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D100000 HACKING / DEMOLITION (CONT'D)

Labour and material in cutting existing brickwork and blockwork


to form groove not exceeding 100mm wide including
removal of debris off site and making good to match existing
(Cont'd)

D100013 No 3.00
Add for each additional stage of 25mm thick walls, floors, etc for
above item (D100012)

D100014 No 1.94
Pipes not exceeding 50mm diameter in brickwork or blockwork not
exceeding 65mm thick
D100015 No 0.76
Add for each additional stage of 25mm thick walls, floors, etc for
above item (D100014)

D100016 No 5.18
Pipes exceeding 50mm diameter and not exceeding 200mm
diameter in brickwork or blockwork not exceeding 65mm thick

D100017 No 1.94
Add for each additional stage of 25mm thick walls, floors, etc for
above item (D100016)

Spout pipes with one end splayed; building in through


brickwork or blockwork

D100018 No 1.19
Not exceeding 25mm diameter unplasticised PVC non-pressure
pipe not exceeding 150mm long

D100019 Exceeding 25mm and not exceeding 50mm diameter No 1.84

D100020 Exceeding 50mm and not exceeding 75mm diameter No 2.48

D100021 Exceeding 75mm and not exceeding 100mm diameter No 3.46


D100022 Add or deduct for each 25mm in length for above item (D100018) No 0.22

D100023 Add or deduct for each 25mm in length for above item (D100019) No 0.32

D100024 Add or deduct for each 25mm in length for above item (D100020) No 0.43

D100025 Add or deduct for each 25mm in length for above item (D100021) No 0.65

BW-D2
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D100000 HACKING / DEMOLITION (CONT'D)

Repointing

D100026 Washing existing pointed brickwalls or blockwalls with caustic m2 1.10


soda or other similar chemical cleaning liquid and remove dirt,
grease, stains, fungus, etc

D100027 Hacking off damaged pointing in joints and re-pointing in cement


m2 10.60
mortar or neat tinted cement as necessary to match existing (one
side only)

D200000 BRICKWORK

Common brick in standard size 215 x 102.5 x 65mm


complying with SS 103, bedding, jointing and pointing in
cement and sand (1:4) mortar reinforced with and including
brick reinforcement at every fourth courses

D200001 65mm thick brick on edge walls


m2 20.70
D200002 102.5mm thick walls m2 26.17

m2 50.31
D200003 215mm thick walls
m2 23.68
D200004 102.5mm thick wall built honeycomb with raking out joints and
flush pointing in tinted cement as the work proceeds

m2 4.10
D200005 Extra over common brickwork for building fair face; raking out
joints and flush pointing in tinted cement as the work proceeds
(one side only)

m2 8.20
D200006 Extra over common brickwork for facing bricks and pointing faces
generally

D200007 Extra over common brickwork for building for facing in first quality m2 10.00
clay facing bricks (one side only)

m2 26.30
D200008 Extra over common brickwork for building for fac ing in clinker
facing bricks (one side only)

D200009 Extra over common brickwork for building for facing in sand face / m2 11.50
perforated facing bricks or plainface perforated facing bricks (one
side only)

BW-D3
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D200000 BRICKWORK (CONT'D)

D200010 Common brick in modular size 190 x 90 x 90mm (Type M211)


complying with SS 103, bedding, jointing and pointing in
cement and sand (1:4) mortar reinforced with and including
brick reinforcement at every fourth courses

D200011 90 mm thick
m2 24.37
D200012 190 mm thick m2 46.07
m2 60.43
D200013 290 mm thick

Engineering brick in standard size 215 x 102.5 x 65mm,


bedding, jointing and pointing in cement and sand (1:4)
mortar reinforced with and including brick reinforcement at
every fourth courses

D200014 65mm thick brick on edge walls m2 31.42


m2 46.65
D200015 102.5mm thick walls
m2 88.80

D200016 215mm thick walls

First quality facing brick in standard size 215 x 102.5 x 65mm


complying with SS 103, bedding, jointing and pointing in
cement and sand (1:4) mortar reinforced with and including
brick reinforcement; raking out joints and flush or struck
pointing as directed by SO as the work proceeds

D200017 102.5mm thick walls built honeycomb; pointing one side m2 34.99

D200018 102.5mm thick walls built honeycomb; pointing both sides m2 39.31

D200019 102.5mm thick walls; pointing one side m2 40.70

D200020 102.5mm thick walls; pointing on both sides m2 54.86

D200021 215mm thick walls; pointing on one side m2 72.30

D200022 215mm thick walls; pointing both sides m2 85.40

D200023 Half brick thick honeycomb brickwork built entirely in clinker facing m2 51.70
bricks one side with joints raked out and pointed in tinted cement
as the work proceeds

BW-D4
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D200000 BRICKWORK (CONT'D)

First quality facing brick in standard size 215 x 102.5 x 65mm


complying with SS 103, bedding, jointing and pointing in
cement and sand (1:4) mortar reinforced with and including
brick reinforcement; raking out joints and flush or struck
pointing as directed by SO as the work proceeds (Cont'd)

D200024 One brick thick brickwork built entirely in clinker facing bricks one m2 94.70
side with joints raked out and pointed in tinted cement as the work
proceeds

D200025 Half brick thick honeycomb brickwork built entirely in sandface / m2 29.50
plain face perforated facing bricks one side with joints raked out
and pointed in tinted cement as the work proceeds

D200026 Half brick thick brickwork built entirely in sandface / plain-face m2 42.10
perforated facing bricks one side with joints raked out and pointed
in tinted cement as the work proceeds

D200027 One brick thick brickwork built entirely in sandface / plain -face m2 76.20
perforated facing bricks one side with joints raked out and pointed
in tinted cement as the work proceeds

D200028 Half brick thick honeycomb brickwork built both sides entirely in m2 32.30
first quality clay facing bricks with joints raked out and pointed in
tinted cement as the work proceeds

D200029 Half brick thick brickwork built both sides entirely in first quality m2 45.60
clay facing bricks with joints raked ouit and pointed in tinted
cement as the work proceeds

D200030 One brick thick brickwork built both sides entirely in first quality m2 80.10
clay facing bricks with joints raked ouit and pointed in tinted
cement as the work proceeds

D200031 Half brick thick built honeycomb brickwork built both sides entirely m2 40.50
in clinker facing bricks with joints raked out and pointed in tinted
cement as the work proceeds

D200032 Half brick thick brickwork built both sides entirely in clinker facing m2 56.40
bricks with joints raked out and pointed in tinted cement as as the
work proceeds

D200033 One brick thick brickwork built both sides entirely in clinker facing m2 101.90
bricks with joints raked out and pointed in tinted cement as the
work proceeds

BW-D5
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D200000 BRICKWORK (CONT'D)

First quality facing brick in standard size 215 x 102.5 x 65mm


complying with SS 103, bedding, jointing and pointing in
cement and sand (1:4) mortar reinforced with and including
brick reinforcement; raking out joints and flush or struck
pointing as directed by SO as the work proceeds (Cont'd)

D200034 Half brick thick brickwork built honeycomb brickwork built both m2 30.30
sides entirely in sandface perforated facing bricks / plain face
perforated facing bricks with joints raked out pointed in tinted
cement as the work proceeds

m2 46.90
D200035 Half brick thick brickwork built both sides entirely in sandface
perforated facing bricks / plain face perforated facing bricks with
joints raked out pointed in tinted cement as the work proceeds

D200036 One brick thick brickwork built both sides entirely in sandface m2 82.80
perforated facing bricks / plain face perforated facing bricks with
joints raked out pointed in tinted cement as the work proceeds

D300000 BLOCKWORK

Hollow concrete block in 390 x 190mm complying with SS


76M, jointing and pointing in cement and sand (1:4) mortar
reinforced with and including brick reinforcement at every
course

D300001 75 mm thick walls


m2 15.82
D300002 100 mm thick walls
m2 17.59
D300003 150 mm thick walls
m2 23.81

Extra over above items for filling in each block solid with
concrete (Grade 15)

D300004 75 mm thick walls

D300005 100 mm thick walls m2 3.24

D300006 150 mm thick walls m2 3.24

D300007 Extra over items (D300001) to (D300 003) above for building m2 2.93
fairface with raking out joints and pointing in cement as the works
proceeds (one side only) m2 2.30

BW-D6
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D300000 BLOCKWORK (CONT'D)

Precast concrete vent block of any size complying with SS


76M, bedding, jointing and pointing in cement and sand (1:4)
mortar reinforced with and including brick reinforcement at
every courses

D300008 100 mm thick walls


m2 77.87
D300009 150 mm thick walls
m2 90.07
m2 55.90
D300010 100mm thick concrete vent block in grille blockwall consisting of
rain-proof concrete vent blocks (any size) bedded and jointed in
cement mortar (1:6) reinforced every course with and including
approved galvanised brick reinforcement

D300011 113mm thick concrete vent block in grille blockwall consisting of m2 57.60
rain-proof concrete vent blocks (any size) bedded and jointed in
cement mortar (1:6) reinforced every course with and including
approved galvanised brick reinforcement

D300012 150mm thick concrete vent block in grille blockwall consisting of m2 69.30
rain-proof concrete vent blocks (any size) bedded and jointed in
cement mortar (1:6) reinforced every course with and including
approved galvanised brick reinforcement

Aerated concrete blocks 590 x 190mm complying with SS 76M,


bedding, jointing and pointing in cement and sand (1:4) mortar
reinforced with and including brick reinforcement at every
courses

D300013 75 mm thick walls


m2 21.50
D300014 100 mm thick walls m2 27.20

m2 2.10
D300015 Extra over items (D300013) to (D300014) above fo r building
fairface with raking out joints and pointing in cement as the work
proceeds (one side only)

Glass Blocks

H o ll o w gl as s bl o ck wi t h ap p r o ved h o ri z o n t al j oi n t
reinforcement placed at every course in cement mortar (1:4);
raking out joints and refilled with white cement mortar (1:2);
flushing pointing both sides as the work proceeds

D300016 80 mm thick walls/panels m2 250.00

BW-D7
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D300000 BLOCKWORK (CONT'D)

Glass Blocks (Cont'd)

H o ll o w gl as s bl o ck wi t h ap p r o ved h o ri z o n t al j oi n t
reinforcement placed at every course in cement mortar (1:4);
raking out joints and refilled with white cement mortar (1:2);
flushing pointing both sides as the work proceeds (Cont'd)

D300017 100mm thick walls/panels


m2 296.40
m2 28.60
D300018 Lay only glass block (any type and size) with approved horizontal
joint reinforcing placed at every course including mortar and
pointing with cement

D400000 GRANITE RUBBLE WALLS

D400001 Hammer dressed random rubble walls in selected granite blocks m3 163.35
laid in cement mortar (1:3) including raking out joints and pointing
in plain or white cement as the work proceeds

D400002 Rendering top of granite wall with cement mortar (1:3) average m2 13.40
50mm thick including layer of mesh reinforcement

D400003 Extra over for setting granite blocks against slipped banks m3 18.80

D500000 SUNDRIES

Bitumen polymer homogeneous horizontal damp proof


course with fibre felt base complying with BS 5628 Part 3 well
lapped at joints and laid on and including cement mortar (1:4)

D500001 Damp proof course irrespective of widths


m2 11.50
m 3.85
D500002 112.5mm wide 3 ply bituminous felt horizontal damp proof course
complying with BS 743 Type B in cement mortar (1:4) with mortar
plasticiser to wall

D500003 225mm wide 3 ply bituminous felt horizontal damp proof course m 5.70
complying with BS 743 Type B in cement mortar (1:4) with mortar
plasticiser to wall

BW-D8
D : BRICKWORK & BLOCKWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

D500000 SUNDRIES (CONT'D)

Bitumen polymer homogeneous horizontal damp proof


course with fibre felt base complying with BS 5628 Part 3 well
lapped at joints and laid on and including cement mortar (1:4)
(Cont'd)

D500004 Exceeding 300mm wide 3 ply bituminous felt horizontal damp m2 13.60
proof course complying with BS 743 Type B in cement mortar (1:4)
with mortar plasticiser to wall

D500005 0.6mm thick polythylene moisture barrier laid to top, side or m2 8.50
underside of concrete structure

D500006 0.8mm thick polythylene moisture barrier laid to top, side or m2 12.40
underside of concrete structure

Brick-on-edge in steps, sills, etc (plan area measured)

D500007 One course brick-on-edge laid in cement mortar (1:3) with 10mm m2 35.85
joints in steps, sills, copings, footpaths etc

D500008 Sisalthene '300' heavy weight building paper laid to top, side or m2 3.00
underside of concrete structure

D500009 Sisalthene '355' heavy weight building paper laid to top, side or m2 4.80
underside of concrete structure

D500010 Supply and apply one coat of "DRIWAL" colourless waterproof m2 4.00
compound to exposed surfaces of fair-faced brickwall

D50001 1 Supply and apply additional coating of "DRIW AL" colourless m2 3.50
waterproof compound to exposed surfaces of fair-faced brickwall

D500012 Prepare and apply "Colpave" sealer along the crack line on walls m 8.00
or slabs to cure leaks

D500013 One course plain quarry tiles (any sizes) laid on cement mortar m2 26.70
(1:3) with 10mm joints in sills, weatherings or copings

D500014 Two courses plain quarry tiles (any sizes) laid on cemen t mortar m2 53.80
(1:3) with 10mm joints in sills, weatherings or copings

BW-D9
SECTION E: ROOFING
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E1 00000 DEMOLITION

Removing existing roof covering and removing off site

E100001 Pattern clay, glass roofing tiles or concrete interlocking tiles and
m2 0.90
the like including ridge and hip tiles

E100002 Pattern clay, glass roofing tiles or concrete interlocking tiles and
the like including taking out battens, ridge and hip tiles m2 1.35

E1 00003 Profiled sheet roofing including ridges m2 1.90

E100004 Removing existing felt roofing including chippings and preparing m2 4.20
surfaces to receive new finishes.

E100005 Removing existing cement panels and preparing surfaces to m2 6.00


receive new finishes.

Removing existing roof coverings and carefully stack aside


where directed for re-use

E100006 Pattern clay, glass roofing tiles or concrete interlocking tiles and m2 0.95
the like including ridge and hip tiles

E100007 Pattern clay, glass roofing tiles or concrete interlocking tiles and
the like including taking out battens, ridge and hip tiles m2 1.25

E100008 Profiled sheet roofing including ridges


m2 2.81
Taking from stack and relay existing roof coverings with and
including new screws, clips, nails, bolts, etc (new roof
coverings measured separately)

E100009 Standard pattern unglazed coloured concrete interlocking tiles; m2 20.95


fixing with galvanised nails on existing battens

E100010 Pattern clay, glass roofing tiles or concrete interlocking tiles and m2 4.35
the like

E100011 Pattern clay, glass roofing tiles or concrete interlocking tiles and m2 26.90
the like with and including preservative timber battens

E100012 Clay or concrete ridge/hip tiles including bedding and pointing in m 3.10
cement mortar (1:3)

E100013 Profiled sheet roofing including ridges m2 5.90

BW-E1
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E1 00000 DEMOLITION (CONT'D)

Taking out existing rainwater goods and remove off site and
making good work disturbed

E100014 m 1.30
Existing rainwater down pipes (any type and size), including all
necessary cutting in position

E100015 Existing rainwater head (any type and size) No 3.24


E100016 m 0.86
Existing rainwater down pipes (any type and size), including all
necessary cutting in position

E100017 Existing valley gutters, flashings and the like m2 5.08

E100018 Existing eaves gutters including brackets where necessary m 1.19

E1 00019 Existing metal holderbats for pipe, (any diameter) No 1.08

Investigating and curing leak in tiled roof including providing


new tiles not exceeding 0.50 m2 in area to match existing
(Note: Individual blocks of building considered separately)

E100020 1st spot of leak No 28.80

E100021 Add for each additional spot of leak No 17.20

Repairing existing built up roofing including make good work


disturbed

E100022 m2 5.80
Removing all bituminous joints, plants, debris, etc cleaning and
filling grooves, cracks, etc with approved sealant and washing
clean to receive new roofing (NOTE: New screed measured
separately)

E100023 No 3.35
Hacking up existing concrete panels and making good in patches,
each patch not exceeding 2 panels and 25mm thick (rate per
patch)

E100024 No 39.65
Hacking up existing concrete panels and making good in patches,
each patch not exceeding 2 panels and 25mm thick including
replacement of 3 layers roofing felt (rate per patch)

panel
roofing,
E100025 Approved bitumastic liquid solution filling to expansion joints of crevices,
BW-E2
E : ROOFING cracks, etc approximately 15mm wide x m 1.10
22mm deep to panel roofing including forming groove if necessary

BW-E3
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E1 00000 DEMOLITION (CONT'D)

Repairing existing built up roofing including make good work


disturbed (Cont'd)

E100026 Taking out existing filling to expansion joints of panel roofing, m 1.80
crevices, cracks etc approximately 15mm wide x 22mm deep and
replace new bituminous liquid solution filling inclu ding all
necessary hacking and forming groove if necessary

E100027 Take out existing valley gutters, flashings, etc, remove off site and m2 6.20
prepare to receive new (Rate for new gutters etc. under Section F
Structural Steelworks and Metalwork).

E100028 Take out existing eaves gutters including brackets where m 1.40
necessary, remove off site and make good work disturbed

E1 00029 Clean out and remove rubbish from roof gutters including outlets. m 1.00

no 1.80
E100030 Take out existing rainwater head (any type and size) and remove
off site.

E100031 Seal existing nail or bolts heads with bitminous sealing compound m2 1.60
on corrugated roofing sheetings (Measured net area from mid
point or nail heads).

E100032 Seal existing nail or bolts heads with liquid - applied membrane of m2 4.80
heavy duty acrylic polyer reinforced by fiber glass compound on
corrugated roofing sheetings (Measured net area from mid point or
nail heads).

E100033 Seal existing side and end laps with bituminous sealing compound m 1.60
irrespective of girth inclusive of cement mortar where necessary.

E100034 Seal existing side and end laps with liquid applied membrane of 5.00
heavy duty acrylic polymer reinforced by fiber glass.

E100035 Prepare existing surfaces of cement rendering, etc. and wash m2 1.70
down to receive finishing.

Sundries

E100036 Supply and fix matching 'J' - hooks to existing corrugated roofing no 5.60
sheets, not exceeding 10 nos. at any one time. (Measured nett, no
allowance made for laps).

E100037 Supply and fix matching 'J' - hooks to existing corrugated roofing no 4.40
sheets, exceeding 10 nos. at any one time. (Measured nett, no
allowance made for laps).
BW-E4
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E1 00000 DEMOLITION (CONT'D)

Sundries (Cont'd)

no 1.10
E100038 Prepare and seal with silicon compound to screw holes of roofing
sheets of quantities not exceeding 20 nos.

no 0.75
E100039 Prepare and seal with silicon compound to screw holes of roofing
sheets of quantities exceeding 20 nos.

m 14.30
E100040 Prepare and seal with silicon compund to defective side - lamps of
roofing sheets flashings, cappings, etc of quantites not exceeding
10m

m 9.90
E100041 Prepare and seal with silicon compund to defective side - lamps of
roofing sheets flashings, cappings, etc of quantites exceeding
10m

E100042 Labour and material cleaning 50mm wide joints of existing roofing m 3.95
sheets/valley gutters and sealed with "Expandite Instantseal"

E100043 Labour and material cleaning 75mm wide joints of existing roofing m 4.95
sheets/valley gutters and sealed with "Expandite Instantseal"

m 5.70
E1 00044 Labour and material cleaning 100mm wide joints of existing roofing
sheets/valley gutters and sealed with "Expandite Instantseal"

no 0.60
E100045 Labour and materials driving to existing sheeting self - tapping
screws not exceeding 13mm diameter x 17mm long including
necessary tools

m2 4.40
E100046 Labour for taking down and removing existing damaged metal
roofing sheets to ENV's dumping ground. (Inclusive of ENV
dumping charges)

no 2.75
E100047 Labour and material for patching up nail holes in metal roofing
sheets with mastic and one layer of bituminous felt.

E100048 Supply and install 150 mm wide bitumen self-adhesive waterproof No 10.20
strip covered with colored foils to roof.

BW-E5
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E200000 TILE ROOFING

Concrete roofing tiles

Standard pattern unglazed coloured concrete interlocking


tiles; fixing with galvanised nails

E200001 Coverings; on and including sawn tanalised kapoh battens


m2 29.81

E200002 Coverings; on and including preservative treated kapoh battens m2 31.50


m 15.12
E200003 Extra over coverings for ridge or hip tiles including angles

and
intersections, bedding and pointing in cement mortar (1:3)

Terra-cotta roofing tiles

Standard pattern unglazed coloured terra-cotta interlocking


tiles complying with SS 70; fixing with galvanised nails

m2 58.00

E200004 Coverings; on and including sawn tanalised kapoh battens m 24.52

m 30.02
E200005 Extra over coverings for right/left hand verge tiles

E200006 Extra over coverings for ridge or hip tiles including angles and
intersections, bedding and pointing in cement mortar (1:3) No 64.04

E200007 Extra over coverings for 3 ways apex tiles

Metal roofing tiles

0.6 mm thick high tensile steel continuous hot dipped


galvanised steel roofing tiles with Kynar 500 Poly-vinylidence
fluoride resin (PVF2) coating fixed to timber battens or steel
purlins (measured separately) with galvanised nails and
screws. m2 53.14
m 17.06
E200008 Coverings

E200009 Extra over coverings for ridge or hip courses

Clay roofing tiles and Interlocking roofing tiles m2 38.00

E200010 Clay roofing (red, brown, grey) standard interlocking tiles to match
existing if in replacement and laid on and including tantalized sawn
kapur battens with copper nails at every alternate course (Net area
measured).
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E200000 TILE ROOFING (CONT'D)

Clay roofing tiles and Interlocking roofing tiles (Cont'd)

E20001 1 Clay roofing (red, brown, grey) standard interlocking tiles to match m2 33.40
existing if in replacement and laid on including new kapur batten
with two coats of approved preservative costing and including
tantalized sawn kapur battens with copper nails at every alternate
course (Net area measured).

E200012 Clay roofing (red, brown, grey) standard interlocking tiles to match m2 19.10
existing if in replacement and laid existing battens (Net area
measured).

E200013 Clay roofing (green, yellow, white) standard interlocking tiles to m2 39.20
match existing if in replacement and laid on and including
tantalized sawn kapur battens with copper nails at every alternate
course (Net area measured)

E200014 Clay roofing (green, yellow, white) standard intrlocking tiles to m2 41.80
match existing if in replacement and laid on including new kapur
battens with two coats of approved preservative coating and
including tantalized sawn kapur battens with copper nails at every
alternate course (Net area measured)

E200015 Clay roofing (green, yellow, white) standard interlocking tiles to m2 22.20
match existing if in replacement and laid on existing battens (Net
area measured)

E200016 Stone coated finished interlocking roofing tiles as specified m2 46.55


including 38mm x 50mm tantalized sawn kapur battens according
to manufacturer's instructions.

E200017 Stone coated finished interlocking roofing tiles as specified m2 49.65


including hips and ridges fixed on to and including new kapur
battens with two coats of approved preservative coating.

E200018 Stone coated finished interlocking roofing tiles as specified m2 43.80


including hips and ridges laid on existing battens

E300000 BUILT-UP ROOFING

Cement and sand (1:3) base or levelling screed with steel


trowel smooth laid on concrete

E300001 25mm thick (average)


m2 10.69
m2 0.43
E300002 Add to above item (E300001) for each additional 5mm thick
cement and sand base or levelling screed
BW-E6
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E300000 BUILT-UP ROOFING (CONT'D)

1.5mm Self adhesive modified bitumen styrene bitudiene


styrene (SBS) waterproofing membrane with welded seams

E300003 On flat surfaces laid to falls m2 16.74

E300004 On vertical surfaces, upturns, skirtings and the like; not exceeding m 10.58
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

E300005 Dressing around vent pipes / rainwater outlets and the like No 19.44

Bituminous felt membrane; sealed and bonded with hot


bitumen

One ply bituminous felt membrane weighing 17.75 kg per


20m2; sealed and bonded with hot bitumen

E300006 On flat surfaces laid to falls m2 6.70

E300007 On vertical surfaces, upturns, skirtings and the like; not exceeding m 12.50
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

Two ply bituminous felt membrane weighing 35.50 kg per


20m2 for each layer; sealed and bonded with hot bitumen

E300008 On flat surfaces laid to falls m2 13.20

E300009 On vertical surfaces, upturns, skirtings and the like; not exceeding m 23.00
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

Three ply bituminous felt membrane; the first and second


layers each weighing 27.00 kg per 20m2 and third layer
weighing 45 kg per 20m2; sealed and bonded with hot
bitumen

E300010 On flat surfaces laid to falls m2 19.90

E30001 1 On vertical surfaces, upturns, skirtings and the like; not exceeding m 35.80
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

E300012 m2 3.00
6mm thick layer of granite chips (3mm size) laid shoulder to
shoulder on and including hot bitumen dressing compound to flat
roof

BW-E7
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E300000 BUILT-UP ROOFING (CONT'D)

Three ply bituminous felt membrane; the first and second


layers each weighing 27.00 kg per 20m2 and third layer
weighing 45 kg per 20m2; sealed and bonded with hot
bitumen (Cont'd)

E30001 3 One coat of hot bituminous compound laid at 1.5 kg per 10 m2 m2 2.00

2.2mm PVC synthetic waterproof membrane

E300014 On flat surfaces laid to falls m2 27.00

E300015 On vertical surfaces, upturns, skirtings and the like; not exceeding m 8.42
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

E30001 6 Dressing around vent pipes / rainwater outlets and the like No 21.06

2mm Ethylene / butyl acrylate copolymer (ECB) waterproof


membrane

E300017 On flat surfaces laid to falls m2 27.32

E300018 On vertical surfaces, upturns, skirtings and the like; not exceeding m 17.17
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

E300019 Dressing around vent pipes / rainwater outlets and the like No 20.00

3mm Torch-on modified bitumen atatic plastomeric polymer


(APP) base waterproof membrane with welded seams

E300020 On flat surfaces laid to falls m2 8.50

E300021 On vertical surfaces, upturns, skirtings and the like; not exceeding m 11.80
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

E300022 Dressing around vent pipes / rainwater outlets and the like No 19.50

1.3mm Liquid applied polyurethane waterproof membrane

E300023 On flat surfaces laid to falls m2 18.10

E300024 On vertical surfaces, upturns, skirtings and the like; not exceeding m 11.40
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing
BW-E8
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E300000 BUILT-UP ROOFING (CONT'D)

1.3mm Liquid applied polyurethane waterproof membrane


(Cont'd)

E300025 Dressing around vent pipes / rainwater outlets and the like
No 19.44

E300026 On flat surfaces laid to falls m2 17.39


m 10.91
E300027 On vertical surfaces, upturns, skirtings and the like; not exceeding
300mm girth; dressed over angle fillet at bottom and turned into
groove at top and including cover flashing

E300028 Dressing around vent pipes / rainwater outlets and the like No 19.44

Extruded polystyrene insulation board (density 35kg/m3)

E300029 50mm thick laid on waterproof membrane (measured separately) m2 13.80


laid to falls

Geotextile separation layer (density 120gm/m2); well lapped

E300030 A layer of separation fleece laid over insulation board as a m2 2.50


separating sheet (measured separately) laid to falls

Concrete (Grade 20) toppings laid in panels of 750 x 750mm


reinforced with fabric reinforcement A6 with polyurethane
expansion joints

E300031 25mm thick (average)


m2 24.70
m2 0.65
E300032 Add to above item for each additional 5mm thick waterproof
cement and sand toppings

m2 18.70
E300033 Average 25 mm thick waterproof cement and sand (1:3) topping
laid in panels of 750mm x 750 mm to slope or flat roof all in
accordance with specialist recommendation including steel
trowelled and finished to falls.

m2 24.40
E300034 Average 25 mm thick waterproof cement and sand (1:3) topping
laid in panels of 750mm x 750 mm to slope or flat roof all in
accordance with specialist recommendation including steel
trowelled and finished to falls in skirting, upstands, eaves, edges,
gutters, etc.

E300035 Add for each additional 5 mm thick waterproof of cement and sand m2 3.10
topping as before described.

BW-E9
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E400000 STEEL ROOFING

Zincalume coated steel roofing or wall cladding, fascia, etc


fixed to steel purlins or timber bearers (measured separately)
with fixing clips and self-tapping screws. (Kliplok, trapezoidal
ribbed, subtle square, Corrugated, Trimdek Hi-ten / Monoclad
/ Trimclad, Spandek Hi Ten / Longspan / Metrospan and flat
panel profile)

E400001 0.47mm thick m2 25.70

E400002 0.53mm thick m2 30.89

E400003 0.65mm thick m2 35.86

Colorbond XRW with zincalume coated steel roofing or wall


cladding, fascia, etc fixed to steel purlins or timber bearers
(measured separately) with fixing clips and self-tapping
screws. (Kliplok, trapezoidal ribbed, subtle square,
Corrugated, Trimdek Hi-ten / Monoclad / Trimclad, Spandek
Hi Ten / Longspan / Metrospan and flat panel profile)

E400004 0.47mm thick m2 30.78

E400005 0.53mm thick m2 36.07

E400006 0.65mm thick m2 39.50

Colorbond XRW with zincalume coated steel curved roofing


or wall cladding, fascia, etc fixed to steel purlins or timber
bearers (measured separately) with fixing clips and self-
tapping screws. (Kliplok, trapezoidal ribbed, subtle square,
Corrugated, Trimdek Hi-ten / Monoclad / Trimclad, Spandek
Hi Ten / Longspan / Metrospan and flat panel profile)

E400007 0.47mm thick m2 31.90

Colorbond XRW with zincalume coated select seam steel


roofing or wall cladding, fascia, etc fixed to steel purlins or
timber bearers (measured separately) with fixing clips and
self-tapping screws

E400008 0.60mm thick m2 59.07

BW-
E10
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E400000 STEEL ROOFING (CONT'D)

Colorbond XPD with zincalume coated steel roofing or wall


cladding, fascia, etc fixed to steel purlins or timber bearers
(measured separately) with fixing clips and self-tapping
screws

E400009 0.47mm thick


m2 35.42
E400010 0.53mm thick
m2 41.47
E400011 0.65mm thick m2 48.17

Colorbond XPD with zincalume coated steel curved roofing


or wall cladding, fascia, etc fixed to steel purlins or timber
bearers (measured separately) with fixing clips and self-
tapping screws

E400012 0.47mm thick

Colorbond XPD with zincalume coated select seam steel m2 50.98


roofing or wall cladding, fascia, etc fixed to steel purlins or
timber bearers (measured separately) with fixing clips and
self-tapping screws

E400013 0.60mm thick

PVF2 coated aluminium standing seam roofing fixed to steel m2 70.85


purlins or timber bearers (measured separately) with fixing
clips and self-tapping screws

E400014 0.80mm thick

Acoustic roof complying to STC 45 comprising of 0.90mm


PVF2 coated aluminium standing seam; two layers of 50mm m2 51.41
thick rockwool insulation (density 60/kg/m3); one layer of
double sided aluminium foil; one layer of 16mm thick cement
board;1.2mm thick galvanised zed subgirth at 1200mm
centres and a layer of 0.47mm thick zincalume linear sheet as
substrate fixed to steel purlins (measured separately) with
fixing clips and self tapping screws

E400015 Coverings

E400016 Supply and fix 0.5mm gauge corrugated aluminium roofing sheet

E400017 Supply and fix 0.5mm gauge corrugated aluminium roofing sheet
m2 116.75
m2 15.00

m2 18.30

BW-
E11
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E400000 STEEL ROOFING (CONT'D)

Acoustic roof complying to STC 45 comprising of 0.90mm


PVF2 coated aluminium standing seam; two layers of 50mm
thick rockwool insulation (density 60/kg/m3); one layer of
double sided aluminium foil; one layer of 16mm thick cement
board;1.2mm thick galvanised zed subgirth at 1200mm
centres and a layer of 0.47mm thick zincalume linear sheet as
substrate fixed to steel purlins (measured separately) with
fixing clips and self tapping screws (Cont'd)

E400018 Supply and fix 0.5mm gauge corrugated aluminium roofing sheet m2 21.60

E400019 Supply and fix 0.5mm gauge corrugated aluminium roofing sheet 5.78

E400020 Supply and fix 0.4mm gauge corrugated galvanised iron sheet with m2 14.80

E400021 Supply and fix 0.5mm gauge corrugated galvanised iron sheet with m2 15.35

E400023 Supply and fix 0.6mm gauge corrugated galvanised iron sheet with m2 16.03

E400024 Supply and fix 0.6mm gauge corrugated galvanised iron sheet with m2 16.38

E400025 Supply and fix 0.6mm gauge corrugated galvanised iron sheet with m2 16.65

E400026 Supply and fix corrugated galvanised iron sheet with 125mm side m2 7.30
m2 230.00
Supply and install aluminium composite panel according to
manufacturer's specification

4mm thick composed of 3mm thick Polyethylene Core/ Fire-rated


mineral/fibreglass sandwiched between two sheets of Aluminum of
0.5mm thickness. The outer top skin shall be coated with PVDF
KYNAR 500(more than 70% PVDF resin)Fluorocarbon coating and
apply protective coating on the back skin. The sound insulation :
25db
Rate inclusive of purlins,etc (measured separately)

Acoustic damping compound


E400027 m2 24.84
Spray one layer of 0.80mm thick lightweight acoustic damping
compound to underside of metal roof sheetings

BW-
E12
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E400000 STEEL ROOFING (CONT'D)

Translucent / Transparent roofing

E400028 Translucent corrugated fiberglass sheeting weighing 1.82kg per


m2 72.70
sq.metre fixed to purlins or rails etc with two corrugations side laps
and with end laps minimum 150mm including all necessary drive
nails and washer or hook bolts and washers, all cutting and fixing
all in accordance with manufacturer's instructions (Net area
measured)

E400029 Translucent corrugated fiberglass sheeting weighing 2.43 kg per


m2 105.70
sq. metre fixed to purlins or rails etc. wiith two corrugations side
laps and with end laps minimun 150mm including all necessary
drive nails and washer or hooker bolts and washers, all cutting and
fixing all in accordance with manufacturer's instructions (Net area
measured)

E400030 PVC transparent corrugated sheeting of the same profile to match


corrugated asbestos,metal or bituminous roofing sheets fixed to m2 23.00
purlins or rails etc. with two corrugations side laps and with
minimum 150mm end laps including all necessary drive nails and
washers or hook bolts and washers, all in accordance with
manufacturer's instructions (Net area measured).

E500000 SHEET METAL FLASHINGS AND GUTTERS

Flashings, trims etc including bending, jointing, dressing,


cutting chased in masonry walls

E500001 0.60mm thick Zincalume flashings x 300mm girth


m 11.23
E500002 0.60mm thick Zincalume flashings x 600mm girth m 16.31

E500003 0.60mm thick Zincalume flashings x 900mm girth m 20.84

E500004 0.60mm thick Colorbond XRW flashings x 300mm girth m 12.42

E500005 0.60mm thick Colorbond XRW flashings x 600mm girth m 19.01

E500006 0.60mm thick Colorbond XRW flashings x 900mm girth m 24.62

E500007 0.60mm thick Colorbond XPD flashings x 300mm girth m 14.26

E500008 0.60mm thick Colorbond XPD flashings x 600mm girth m 22.90

E500009 0.60mm thick Colorbond XPD flashings x 900mm girth m 30.56

BW-
E13
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E500000 SHEET METAL FLASHINGS AND GUTTERS (CONT'D)

Flashings, trims etc including bending, jointing, dressing,


cutting chased in masonry walls (Cont'd)

E500010 0.80mm thick PVF2 coated flashings x 600mm girth m 48.50

E50001 1 0.60mm thick Zincalume cappings x 300mm girth m 10.20

E500012 0.60mm thick Zincalume cappings x 600mm girth m 15.30

Ridges capping for pitch roof, notched and dressed down


between ribs and fix with approved fasteners (measured nett)

E50001 3 0.60mm thick Colorbond XRW cappings x 300mm girth m 11.40

E500014 0.60mm thick Colorbond XRW cappings x 600mm girth m 17.93

E500015 0.60mm thick Colorbond XPD cappings x 300mm girth m 13.18

E50001 6 0.60mm thick Colorbond XPD cappings x 600mm girth m 21.82

E500017 0.70mm thick PVF2 coated cappings x 600mm girth m 48.50

Open box gutters complete with bends, stopped ends,


balloon gratings, outlets and fixing with and including
galvanised steel brackets

E50001 8 1.0mm thick Zincalume gutters x 600mm girth m 39.74

E50001 9 1.0mm thick Zincalume gutters x 1200mm girth m 62.64

3.00mm thick PVF2 coated aluminium bullnose cladding

E500020 Bullnose claddings; girth not exceeding 1800mm m 349.92

E500021 Bullnose claddings; girth not exceeding 2400mm m 466.56

Aluminium Sheeting all as before described (measured nett,


no allowance for laps)

E500022 m2 33.80
24 gauge aluminium sheet for fabricating valley gutters, box
gutters, eaves gutters, flashings, fitments, etc (brackets for gutters
measured separately)

E500023 22 gauge ditto (ditto) m2 38.77


BW-
E14
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E500000 SHEET METAL FLASHINGS AND GUTTERS (CONT'D)

Aluminium Sheeting all as before described (measured nett,


no allowance for laps) (Cont'd)

E500024 20 gauge ditto (ditto) m2 43.74

E500025 18 gauge ditto (ditto) m2 49.25

E500026 14 gauge ditto (ditto) m2 74.95

Stainless Steel Sheeting all as before described (measured


nett, no allowance for laps)

E500027 m2 113.94
18 gauge stainless steel sheet for fabricating valley gutters, box
gutters, eaves gutters, flashings, fitments, etc to any size and
shape, (brackets for gutters measured separately)

E500027 20 gauge ditto (ditto) m2 90.07

E500027 22 gauge ditto (ditto) m2 77.11

E500027 27 gauge ditto (ditto) m2 38.09

E600000 RAINWATER GOODS

Unplasticised polyvinyl chloride rainwater downpipe and


fittings jointed with solvent welded joints

E600001 75mm diameter m 9.55

E600002 100mm diameter m 11.90

E600003 150mm diameter m 22.45

E600004 200mm diameter m 53.78

Extra over pipes for fittings

E600005 75mm diameter bends/elbows No 7.34

E600006 100mm diameter bends/elbows No 8.42

F500007 150mm diameter bends/elbows No 14.15

E600008 200mm diameter bends/elbows No 19.01


BW-
E15
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Unplasticised polyvinyl chloride rainwater downpipe and


fittings jointed with solvent welded joints (Cont'd)

Extra over pipes for fittings (Cont'd)

E600009 75mm diameter shoes No 11.34

E600010 100mm diameter shoes No 13.39

E600011 150mm diameter shoes No 17.71

E600012 200mm diameter shoes No 26.40

Rainwater outlets; flat grating; luting flange for finishes;


setting in concrete slabs; jointing to rainwater downpipes

E600013 75mm diameter No 48.60

E600014 100mm diameter No 69.70

E600015 150mm diameter No 84.30

E600016 200mm diameter No 102.60

Galvanised mild steel holderbats for rainwater downpipes and


fittings

E600017 75mm diameter No 3.89

E600018 100mm diameter No 4.32

E600019 150mm diameter No 9.07

E600020 200mm diameter No 11.34


E600021 m 10.20
Supply and install 50mm diameter UPVC scupper drain pipe /
rainwater down pipe

Roof Insulation

E600022 Supply and installation of 50mm thick approved moulded m2 25.20


expanded polystyrene board (laid to falls) with self-interlocking
system as described laid in strict accordance with Manufacturer's
instructions

BW-
E16
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages

m2 20.20
E600023 Formstar clear/coloured weather proof coatings system on flat
surfaces laid to fall not exceeding 50sq m.

E600024 Formstar clear/coloured weather proof coatings system on flat m2 18.60


surfaces laid to fall exceeding 50sq m.

E600025 Formstar clear/coloured weather proof coatings system on wall, m2 21.00


parapet wall, plinth gutter, skirting, upstand and the like exceeding
150 mm girth.

E600026 Prepare new roof decking and apply 2 coats of Flinkote PF 4 or m2 9.10
Shellkote Type 3.

E600027 Prepare new wall cladding and apply 2 coats of Flinkote PF 4 or


Shellkote Type 3. m2 9.70

E600028 Prepare new metal or concrete roof decking and apply 2 coats of
bitumen solution and 2 coats santex-matt coating. m2 10.60

E600029 Prepare existing metal or concrete roof decking previously painted


with sandtex-matt coating, clean and apply 2 coats of sandtex-matt m2 9.10
coating.

E600030 Prepare new wall cladding and apply 2 coats of bitumen solution m2 11.20
and 2 coats santex-matt coating.

E600031 Prepare existing wall cladding previously painted with sandtex -


m2 9.70
matt coating, clean and apply 2 coats of sandtex-matt coating.

E600032 Brush down and apply one coat of approved bituminous base m2 5.50
aluminium solution formulated with high grade bitumen and finely
divided aluminium on surfaces of roofing felt, asphalt, concrete,
etc.

E600033 Brush down and apply 3 coats of rubberized flat paint on cement m2 17.30
rendering surface

E600034 Supply and apply Vandex waterproofing compound to concrete m2 24.00


surface including labour and materials for surface preparation, etc.
in accordance with manufacturer's instructions.

E600035 Supply and apply QUIC-seal 102 waterproofing compound to


concrete surfaces including labour and materials for surface m2 14.30
preparation, etc. in accordance with manufacturer's instructions.
BW-E17
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)
E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600036 Supply and lay Bituthene 3000 waterproofing membrane to m2 13.80


concrete surface including labour and materials for surfac e
preparation and apply one coat of bituthene primer to receive
waterproofing membrane, all as specified and in accordance with
the manufacturer's instructions (rate inclusive of the provision of a
10-year warranty).

E600037 Prepare and apply Bituthene EM3000 elastomeric sealant in and


including forming of 25 mm width chases in concrete structure, all m 7.30
in accordance with manufacturer's instructions.

E600038 Supply and lay approved felt as protective cover to Bituthene 3000
waterproofing membrane including EM3000 mastic adhesive. m2 7.80

E600039 Supply and lay over flat roof in 1 mx1 m x25mm thick panels in
cement and sand (1:2) mortar mixed with Sika waterproofing m2 21.60
compound as per manufacturer's instructions in the proportion of
2.3 kg of waterproofing compound to 45 kg of cement and 10 m
joints subsequently filled with and including bituminous compound.

Break up existing cement panels, clean up surface and remove


debris, hack to form key and supply and lay one layer of Bituprimer m2 48.00
and one layer of Asbestumen, each layer is to be about 1.6 mm
thick; supply and lay over the Bituprima layer 25 mm thick cement
and sand (1:2) mortar mixed with waterproofing compound of Sika
or other approved waterproofing compound in accordance with the
manufacturer's instructions. The cement and sand mortar shall be
laid in panels of not more than 1 m x 1 m square with joints 10 mm
wide filled with and including bituminous compound.

E600040 Supply and lay new Bituflex BF-160 self-adhesive waterproof


membrane to existing roof surfaces all in accordance with the m2 19.80
manufacturer's instructions.

E600041 Supply and lay one coat of Bituprima or Bituproof prior to the
application of bitumastic compound as a base. m2 4.20

E 6 0 0 0 4 2 S u p p l y a n d l a y o n e l a ye r o f B i t u p ri m a a n d o n e l a y e r o f
Asbestumen bitumastic solution to an average thickness of 1.6 m2 7.40
mm each layer.

E600043 On flat surfaces laid to fall not exceeding 50sq m, 2.1 mm thick
"Nuralite" roof covering system laid in panels of 2.40 m x 0.90 m. m2 57.00

BW-E18
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600044 On flat surfaces laid to fall exceeding 50sq m, 2.1 mm thick m2 41.60
"Nuralite" roof covering system laid in panels of 2.40 m x 0.90 m.

E600045 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 62.80
upstand and the like not exceeding 50sq m, 2.1 mm thick
"Nuralite" roof covering system laid in panels of 2.40 m x 0.90 m.
E600046 m2 45.40
Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting,
upstand and the like exceeding 50sq m, 2.1 mm thick "Nuralite"
roof covering system laid in panels of 2.40 m x 0.90 m.

E600047 No 21.80
Dressing around vent pipes/rainwater outlets and the like, 2.1 mm
thick "Nuralite" roof covering system laid in panels of 2.40 m x 0.90
m.

E600048 On flat surfaces laid to fall not exceeding 50sq m, 2.00 mm thick m2 44.40
"Carbofol" roof covering system.

E600049 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 48.80
upstand and the like not exceeding 50sq m, 2.00 mm thick
"Carbofol" roof covering system.

E600050 On flat surfaces laid to fall exceeding 50sq m, 2.00 mm thick m2 37.00
"Carbofol" roof covering system.
E600051 m2 40.80
Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting,
upstand and the like exceeding 50sq m, 2.00 mm thick "Carbofol"
roof covering system.

E600052 No 21.80
Dressing around vent pipes/rainwater outlets and the like, 2.00
mm thick "Carbofol" roof covering system.

E600053 On flat surfaces laid to fall not exceeding 50sq m, 1.00 mm thick m2 63.00
"Skellurup Butyclad" roof covering system.

E600054 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 69.40
upstand and the like not exceeding 50sq m, 1.00 mm thick
"Skellurup Butyclad" roof covering system.

E600055 On flat surfaces laid to fall exceeding 50sq m, 1.00 mm thick m2 58.00
"Skellurup Butyclad" roof covering system.
BW-E19
E : ROOFING
m2 63.00
E600056 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting,
upstand and the like exceeding 50sq m, 1.00 mm thick "Skellurup
Butyclad" roof covering system.

BW-E20
E : ROOFING
ITEM NO. DESCRIPTION UNIT RATE
(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600057 Dressing around vent pipes/rainwater outlets and the like, 1.00 No 13.90
mm thick "Skellurup Butyclad" roof covering system.

E600058 On flat surfaces laid to fall not exceeding 50sq m, Traffigard roof m2 47.90
covering.

E600059 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 52.70
upstand and the like not exceeding 50sq m, Traffigard roof
covering.

E600060 On flat surfaces laid to fall exceeding 50sq m, Traffigard roof m2 32.80
covering.

E600061 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 35.30
upstand and the like exceeding 50sq m, Traffigard roof covering.

E600062 Dressing around vent pipes/rainwater outlets and the like, No 11.00
Traffigard roof covering.

E600063 On flat surfaces laid to fall not exceeding 50sq m, 4 mm thick m2 47.20
"Polygum" roof covering system.

E600064 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 50.30
upstand and the like not exceeding 50sq m, 4 mm thick "Polygum"
roof covering system.

E600065 On flat surfaces laid to fall exceeding 50sq m, 4 mm thick m2 38.90


"Polygum" roof covering system.

E600066 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 47.90
upstand and the like exceeding 50sq m, 4 mm thick "Polygum"
roof covering system.

E600067 Dressing around vent pipes/rainwater outlets and the like, 4 mm No 21.80
thick "Polygum" roof covering system.

E600068 On flat surfaces laid to fall not exceeding 50sq m, 4 mm thick m2 23.30
"Index" roof covering system.

E600069 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 25.60
upstand and the like not exceeding 50sq m, 4 mm thick "Index"
roof covering system.

E600070 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 24.50
upstand and the like exceeding 50sq m, 4 mm thick "Index" roof
covering system.
BW-E21
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600071 m2 21.50
On flat surfaces laid to fall exceeding 50sq m, 4 mm thick "Index"
roof covering system.
E600072 No 21.80
Dressing around vent pipes/rainwater outlets and the like, 4 mm
thick "Index" roof covering system.

E600073 On flat surfaces laid to fall not exceeding 50sq m, 4.50 mm thick m2 33.40
"Index Mineral Green" roof covering system.

E600074 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 36.70
upstand and the like not exceeding 50sq m, 4.50 mm thick "Index
Mineral Green" roof covering system.

E600075 On flat surfaces laid to fall exceeding 50sq m, 4.50 mm thick m2 30.80
"Index Mineral Green" roof covering system.

E600076 Supply & lay on wall, parapat wall, conc. plinth, rc gutter, skirting, m2 35.30
upstand and the like exceeding 50sq m, 4.50 mm thick "Index
Mineral Green" roof covering system.

E600077 No 21.80
Dressing around vent pipes/rainwater outlets and the like, 4.50
mm thick "Index Mineral Green" roof covering system.

E600078 On flat surfaces laid to fall not exceeding 50sq m, 0.9mm "Hypalon m2 42.20
Uniroof Membrane" - Fibre Backed roof covering system.

E600079 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 46.40
upstands and the like not exceeding 50sq m, 0.9mm "Hypalon
Uniroof Membrane" - Fibre Backed roof covering system.

E600080 On flat surfaces laid to fall exceeding 50sq m, 0.9mm "Hypalon m2 41.60
Uniroof Membrane" - Fibre Backed roof covering system.

E600081 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 45.80
upstands and the like exceeding 50sq m, 0.9mm "Hypalon Uniroof
Membrane" - Fibre Backed roof covering system.

E600082 Dressing around vent pipes/rainwater outlets and the like, 0.9mm No 21.90
"Hypalon Uniroof Membrane" - Fibre Backed roof covering system.

BW-E22
E : ROOFING
E600083 On flat surfaces laid to fall not exceeding 50sq m, 1.2mm "Hypalon m2 47.90
Uniroof Membrane" - Fibre Backed roof covering system.

BW-E23
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600084 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 52.70
upstands and the like not exceeding 50sq m, 1.2mm "Hypalon
Uniroof Membrane" - Fibre Backed roof covering system.

E600085 On flat surfaces laid to fall exceeding 50sq m, 1.2mm "Hypalon m2 46.70
Uniroof Membrane" - Fibre Backed roof covering system.

E600086 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 51.40
upstands and the like exceeding 50sq m, 1.2mm "Hypalon Uniroof
Membrane" - Fibre Backed roof covering system.

E600087 Dressing around vent pipes/rainwater outlets and the like, 1.2mm No 21.80
"Hypalon Uniroof Membrane" - Fibre Backed roof covering system.

E600088 On flat surfaces laid to fall not exceeding 50sq m, 0.9mm "Hypalon m2 50.20
Uniroof Reinforced Membrane" roof covering system.

E600089 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 55.20
upstands and the like not exceeding 50sq m, 0.9mm "Hypalon
Uniroof Reinforced Membrane" roof covering system.

E600090 On flat surfaces laid to fall exceeding 50sq m, 0.9mm "Hypalon m2 47.90
Uniroof Reinforced Membrane" roof covering system.

E600091 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 52.70
upstands and the like exceeding 50sq m, 0.9mm "Hypalon Uniroof
Reinforced Membrane" roof covering system.

E600092 Dressing around vent pipes/rainwater outlets and the like, 0.9mm No 21.80
"Hypalon Uniroof Reinforced Membrane" roof covering system.

E600093 On flat surfaces laid to fall not exceeding 50sq m, 1.2mm "Hypalon m2 51.70
Uniroof Reinforced Membrane" roof covering system.

E600094 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 56.90
upstands and the like not exceeding 50sq m, 1.2mm "Hypalon
Uniroof Reinforced Membrane" roof covering system.

E600095 On flat surfaces laid to fall exceeding 50sq m, 1.2mm "Hypalon m2 50.40
Uniroof Reinforced Membrane" roof covering system.

BW-E24
E : ROOFING
m2 55.40
E600096 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting,
upstands and the like exceeding 50sq m, 1.2mm "Hypalon Uniroof
Reinforced Membrane" roof covering system.

BW-E25
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600097 Dressing around vent pipes/rainwater outlets and the like, 1.2mm No 21.80
"Hypalon Uniroof Reinforced Membrane" roof covering system.

E600098 On flat surfaces laid to fall not exceeding 50sq m, 3mm "Uniflame" m2 34.10
Polyester Based Torch-On roof covering system.

E600099 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 37.40
upstands and the like not exceeding 50sq m, 3mm "Uniflame"
Polyester Based Torch-On rooof covering system.

E600100 On flat surfaces laid to fall exceeding 50sq m, 3mm "Uniflame" m2 32.40
Polyester Based Torch-On roof covering system.

E600101 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 35.60
upstands and the like exceeding 50sq m, 3mm "Uniflame"
Polyester Based Torch-On roof covering system.

E600102 Dressing around vent pipes/rainwater outlets and the like, 3mm No 21.80
"Uniflame" Polyester Based Torch-On roof covering system.

E600103 On flat surfaces laid to fall not exceeding 50sq m, 4mm "Uniflame" m2 36.60
Polyester Based Torch-On roof covering system.

E600104 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 40.30
upstands and the like not exceeding 50sq m, 4mm "Uniflame"
Polyester Based Torch-On rooof covering system.

E600105 On flat surfaces laid to fall exceeding 50sq m, 4mm "Uniflame" m2 33.60
Polyester Based Torch-On roof covering system.

E600106 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 37.00
upstands and the like exceeding 50sq m, 4mm "Uniflame"
Polyester Based Torch-On roof covering system.

E600107 Dressing around vent pipes/rainwater outlets and the like, 4mm No 21.80
"Uniflame" Polyester Based Torch-On roof covering system.

E600108 On flat surfaces laid to fall not exceeding 50sq m, "Duraroof" m2 39.10
Polyurethane Based Liquid Membrane roof covering system.

E600109 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 43.10
upstands and the like not exceeding 50sq m, "Duraroof"
Polyurethane Based Liquid Membrane roof covering system.
BW-E26
E : ROOFING
E600110 On flat surfaces laid to fall exceeding 50sq m, "Duraroof" m2 37.80
Polyurethane Based Liquid Membrane roof covering system.

BW-E27
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E6001 11 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 41.60
upstands and the like exceeding 50sq m, "Duraroof" Polyurethane
Based Liquid Membrane roof covering system.

E600112 No 21.80
Dressing around vent pipes/rainwater outlets and the like,
"Duraroof" Polyurethane Based Liquid Membrane roof covering
system.

E600113 On flat surfaces laid to fall not exceeding 50sq m, "Chevaline m2 33.00
Dexx" Liquid Applied Membrane Roof Covering System.

E600114 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 36.40
upstands and the like not exceeding 50sq m, "Chevaline Dexx"
Liquid Applied Membrane Roof Covering System.

E600115 On flat surfaces laid to fall exceeding 50sq m, "Chevaline Dexx" m2 30.40

Liquid Applied Membrane Roof Covering System.

E600116 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 33.40
upstands and the like exceeding 50sq m, "Chevaline Dexx" Liquid
Applied Membrane Roof Covering System.

E600117 m2 21.80
Dressing around vent pipes/rainwater outlets and the like,
"Chevaline Dexx" Liquid Applied Membrane Roof Covering
System.

E600118 On flat surfaces laid to fall not exceeding 50sq m, "Vulken 801" m2 52.90
Liquid Applied Elastomeric Membrane Roof Covering System.

E600119 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 58.20
upstands and the like not exceeding 50sq m, "Vulken 801" Liquid
Applied Elastomeric Membrane Roof Covering System.

E600120 On flat surfaces laid to fall exceeding 50sq m, "Vulken 801" Liquid m2 47.30
Applied Elastomeric Membrane Roof Covering System.

E600121 m2 52.10
Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting,
upstands and the like exceeding 50sq m, "Vulken 801" Liquid
Applied Elastomeric Membrane Roof Covering System.

BW-E28
E : ROOFING

E600122 Dressing around vent pipes/rainwater outlets and the like, "Vulken m2 11.00
801" Liquid Applied Elastomeric Membrane Roof Covering
System.

BW-E29
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600123 On flat surfaces laid to fall not exceeding 50sq m, 2 mm thick "L & m2 50.60
M Santac" Sheet.

E600124 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 56.30
upstands and the like not exceeding 50sq m, 2 mm thick "L & M
Santac" Sheet.

E600125 On flat surfaces laid to fall exceeding 50sq m, 2 mm thick "L & M m2 47.90
Santac" Sheet.

E600126 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 52.70
upstands and the like exceeding 50sq m, 2 mm thick "L & M
Santac" Sheet.
E600127 m2 18.00
Dressing around vent pipes/rainwater outlets and the like, 2 mm
thick "L & M Santac" Sheet.

E600128 On flat surfaces laid to fall not exceeding 50sq m, 3mm "Impec" m2 24.00
Roof Covering System.

E600129 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 26.40
upstands and the like not exceeding 50sq m, 3mm "Impec" Roof
Covering System.

E600130 On flat surfaces laid to fall exceeding 50sq m, 3mm "Impec" Roof m2 21.60
Covering System.

E600131 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 24.00
upstands and the like exceeding 50sq m, 3mm "Impec" Roof
Covering System.

E600132 Dressing around vent pipes/rainwater outlets and the l ike, 3mm m2 17.40
"Impec" Roof Covering System.

E600133 On flat surfaces laid to fall not exceeding 50sq m, 4mm "Impec" m2 25.80
Roof Covering System.

E600134 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 27.60
upstands and the like not exceeding 50sq m, 4mm "Impec" Roof
Covering System.

E600135 On flat surfaces laid to fall exceeding 50sq m, 4mm "Impec" Roof m2 23.50
BW-E30
E : ROOFING
Covering System.

BW-E31
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E600000 RAINWATER GOODS (CONT'D)

Repair Roof / Wall Leakages (Cont'd)

E600136 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 25.80
upstands and the like exceeding 50sq m, 4mm "Impec" Roof
Covering System.

E600137 Dressing around vent pipes/rainwater outlets and the like, 4mm m2 17.40
"Impec" Roof Covering System.

E600138 On flat surfaces laid to fall not exceeding 50sq m, 4.5 mm thick m2 34.20
"Imper" Mineral Green Roof Covering System.

E600139 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 36.60
upstands and the like not exceeding 50sq m, 4.5 mm thick "Imper"
Mineral Green Roof Covering System.

E600140 On flat surfaces laid to fall exceeding 50sq m, 4.5 mm thick m2 32.40
"Imper" Mineral Green Roof Covering System.

E600141 Supply & lay on wall, parapet wall, conc. Plinth, rc gutter, skirting, m2 34.80
upstands and the like exceeding 50sq m, 4.5 mm thick "Imper"
Mineral Green Roof Covering System.

E600142 Dressing around vent pipes/rainwater outlets and the like, 4.5 mm m2 18.70
thick "Imper" Mineral Green Roof Covering System.

E700000 FABRIC STRUCTURES

E700001 Design, supply and install fabric tension membrane canopy m2 1,024.70
comprising of poly tetra fluoro ethylene (PTFE) coated structural
fibreglass membranes; solar transmission of 13% with a visible
light transmission of 11% structures attached to galvanised mild
steel supporting framework with membrane base plates, clamp
bars and strands cables. (measured on 'plan' area)

Note:
i) The lump sum stated against each item below is for the whole
complex and for work done NOT in conjunction with General
Repairs and Redecoration works

ii) In the event other type of buildings are involved, these lump
sum cost shall serve as a basis for ascertaining for cost
variations considering the similarities in design and shape,
height, area, etc and the cost variations can be pro-rated
accordingly from the lump sum costs the decision of the SO
will be final
BW-E32
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E900000 WATERPROOFING SYSTEM

D esi g n , su p p l y an d l a y 5 - co at li q u i d ap p li ed acr yli c


waterproofing system in accordance to the manufacturer's
instructions.

Note:
Please refer to Preambles on warranty period.

E900001 On flat surfaces laid to fall m2 34.56


E900002 m2 37.80
Wall, parapet wall, conc. plinth, r.c. gutter, skirting, upstand and
the like

E900003 Dressing around vent pipes/rainwater outlets and the like No. 10.00

Design, supply and lay 4mm thick torch-on waterproofing


membrane system in accordance to the manufacturer's
instructions.

E900004 On flat surfaces laid to fall m2 42.12

E900005 m2 45.40
Wall, parapet wall, conc. plinth, r.c. gutter, skirting, upstand and
the like

BW-E27
E : ROOFING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

E900000 WATERPROOFING SYSTEM (CONT'D)

Design, supply and lay 5-coat elastomeric waterproofing


membrane system in accordance to the manufacturer's
instructions

E900006 Dressing around vent pipes/rainwater outlets and the like No 19.66

E900007 On flat surfaces laid to fall m2 30.24


E900008 m2 34.56
Wall, parapet wall, conc. plinth, r.c. gutter, skirting, upstand and
the like

E900009 Dressing around vent pipes/rainwater outlets and the like No 19.66

BW-E28
SECTION F: CARPENTRY & JOINERY
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION

Insulation

F100001 Taking out existing fibreglass / mineral wool and woodwool slabs
insulation including laminated with aluminium foil if any, carting m2 0.50
away from site and making good surround

F100002 Taking out existing aluminium foil insulation, carting away from site
and making good surround m2 0.50

Flooring

F100003 Taking out existing boarding (any type and thickness) and carting
away off site m2 2.30

F100004 Taking out existing boarding (any type and thickness ) in floors,
walls, partition, table tops, fitments, etc relaying and recramping m2 7.35
(bearers and new boarding measured separately)

F100005 Scrape off damaged parquet floor tiles and remove all adhesive
stains including remove debris from site m2

Bearers and framing

F100006 Cutting out lengths of existing beads, picture rails, skirtings,


m 1.50
architraves, fillets, cornices. etc (any size) removing off site and
where necessary preparing cut surfaces to receive new

F100007 Labour cutting existing framing to form grooves, rebates, throats,


etc not exceeding 1500 mm2 in sectional area m 3.00

Wall linings

F100008 Stripping out existing laminated plastic lining, removing off site and
m2 3.40
preparing surfaces to receive new

F100009 Taking out existing linings (any type and thickness) from partitions,
counter tops, fitments, wall panels and the like, removing old m2 2.30
boards off site and preparing surrounds to receive new

F100010 Taking out existing linings (any type and thickness) from partitions,
counter tops, fitments, wall panels and the like, set aside for reuse m2 1.90
and preparing surrounds to receive new

F100011 Taking from stack and refixing lining including new fasteners
m2 4.54
F100012 Take from stack and refix old lining (not exceeding 6mm m2 3.55

thick)
including new fasteners

BW-F1
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Wall linings

F100013 Take from stack and refix old lining (exceeding 6mm thick and not
exceeding 15mm thick) including new fasteners m2 4.40

F100014 Take from stack and refix old lining (exceeding 15mm thick)
including new fasteners m2 5.30

Partitions

F1 00015 Taking down existing timber partitions and removing off site
m2 7.35
F100016 Taking down existing timber partitions and rebuild in large sections m2 16.80
using the same material and carting away remaining off site

F100017 Labour and materials for cutting opening in partitions to receive air-
condition frame, ducts, telephone tray, etc (any size) and including No 23.65
additional bearers (new air-condition frame and telephone tray
measured separately)

F100018 Labour and materials for cutting opening in partitions to receive ducts,
telephone tray, etc (any size) and including additional bearers No 64.10
(new opening frame and telephone tray/ducting measured
separately)

F100019 Making opening in existing partition and fixing frames (any size)
for air-conditioner including making good surrounds and carting No 59.90
away debris off site. (frames for air-condition supplied)

Door repairs

Taking down ledged and braced shutters or doors (any type)


replacing not more than three ledges and/or braces by new
and rehanging including carting away old materials (area of
door measured)

F100020 Not exceeding 3.00 m2


m2 17.29
F100021 Exceeding 3.00 m2
m2 23.50

Replacing boarding in ledged and braced shutters or doors


including taking down, re-hanging and carting away old
materials (area of door measured)

F100022 Not exceeding 0.20 m2 (any type)


m2 17.29
F100023 Exceeding 0.20 m2 and but exceeding 3.00 m2 (any type)
m2 26.43

BW-F2
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Door repairs (Cont'd)

Taking down framed, ledged and braced shutters replacing


not more than three ledges, frames and/or braces, glazing bars
by new and rehanging including carting away old materials

F100024 Not exceeding 3.00 m2 (any type) m2 20.80


m2 25.43
F100025 Exceeding 3.00 m2 (any type)

Replacing boarding in framed, ledged and braced shutters or


doors not exceeding 3.00 m2 i ncluding taking down,
rehanging and removing old boards off site
m2 25.70
F100026 Not exceeding 0.20 m2 (any type) m2 33.35
F100027 Exceeding 3.00 m2 (any type)

Taking down casement windows, shutters or doors, etc,


removing ironmongery and removing remainder off site, or
carting away off site
No 4.15
F100028 Not exceeding 3.00m2 (rate measured by per leaf )
m2 1.25
F1 00029 Exceeding 3.00 m2 (rate measured by area of leaf) No 14.35

F100030 Not exceeding 3.00 m2 per leaf but replacing, wedging, cramping
u p , s e c u ri n g a l l jo i n t s , r e f i xi n g , re h a n g i n g a n d a d ju s t i n g
ironmongery (new ironmongery measured separately) m2 6.00

F100031 Exceeding 3.00 m2 per leaf but replacing, wedging, cramping up,
securing all joints, refixing, rehanging and adjusting ironmongery
(new ironmongery measured separately) (rate measured by area
of leaf)

Fixing and hanging only casement windows, shutters or


doors (excluding supply of new ironmongery and frames)
No 7.05
F100032 Not exceeding 3.00 m2 (excluding supply of new ironmongery and
frames) (rate measured by per leaf)
m2 2.95
F100033 Exceeding 3.00 m2 (excluding supply of new ironmongery and
frames) (rate measured by area of door)

BW-F3
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Door repairs (Cont'd)

Taking down casement windows or doors, taking out part or


whole panels or louvres, preparing rails, stiles and muntins
as necessary for glazing including providing beads, replacing
wedges, cramping up, securing all joints, refixing, rehanging
and adjusting ironmongery (new ironmongery measured
separately)
No 47.20
F100034 Not exceeding 3.00 m2 (any type) (rate measured by per leaf of
windows or doors)
m2 19.70
F1 00035 Exceeding 3.00 m2 (any type) (rate measured by area of windows
or doors)

Taking down existing timber doors, trimming to reduce height


not exceeding 50 mm, adjusting door and rehanging. (new
ironmongery measured separately)

F100036 Not exceeding 3.00 m2 (rate measured by per leaf of doors)


No 25.20
m2 10.50
F1 00037 Exceeding 3.00 m2 (rate measured by area of windows or doors)

Taking out one only of either stiles, muntins or glazing bars in


wrought panelled, glazed or louvred casements, shutters or
doors (any type) removing off site and replacing the rails, etc
by new to match including taking down, splicing, framing up
and rehanging as necessary (new ironmongery measured
separately)

F100038 Per leaf of casement, shutters or doors


No 41.15
F100039 Taking out one only of either stiles, muntins or glazing bars in No 31.15
wrought panelled, glazed or louvred casements, shutters or doors
(any type) not exceeding 3.00 sq m, removing off site and
replacing the rails, etc by new to match including taking down,
splicing, framing up and rehanging as necessary (new
ironmongery measured separately)

Replacing one side or both sides plywood (any thickness)


panels or solid wrought timber panels in windows, shutters
or doors including taking down, framing up and rehanging as
necessary, and removing panels off site (rate measured by
area of windows, shutters or doors)

F1 00040 Panels (rate measured by area of windows, shutters or doors) m2 25.38

F100041 Not exceeding 3 louvres m2 27.54

BW-F4
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Door repairs (Cont'd)

Replacing one side or both sides plywood (any thickness)


panels or solid wrought timber panels in windows, shutters
or doors including taking down, framing up and rehanging as
necessary, and removing panels off site (rate measured by
area of windows, shutters or doors) (Cont'd)
No 31.45
F100042 Taking out existing f rames for door, window, etc providing
temporary support if necessary, removing off site and making good
reveals

F100043 Replace plywood ( any thickness) panels or solid wrot timber m2 19.20
panels in windows, shutters or doors exceeding 3.00 sq m
including taking down, framing up and rehang as necessary, and
removing old panels off site (new ironmongery measured
separately) (area of door measured)

F100044 Replace small area (not exceeding 3 louvres) of louvre s in m2 20.80


window, shutters or doors exceeding 3.00 sq m, including taking
down, framing up and rehang as necessary, and removing old
panels off site (new ironmongery measured separately)(area of
door measured)

F100045 Taking out existing frames for door, window , etc providing No 28.93
temporary support if necessary, cramping up, re-wedging joints
and refixing and making good reveals

F100046 Easing and adjusting doors and windows (any type and size) No 12.78
including taking down and rehanging as necessary

F100047 Easing and adjusting doors and windows (any type and size) No 13.90
without taking down including making good disturbed areas as
necessary

F1 00048 Labour for preparing existing door jambs to receive new work.
No 4.00
No 68.45
F100049 Labour for cutting holes in door (any size and shape) and fixed with
louvres

F1 00050 1mm aluminium or galvanised iron sheeting on surface of doors m2 22.25


including pinning with non-ferrous nails

F100051 1mm aluminium or galvanised iron sheeting including pinning with m2 25.16
non-ferrous nails, preparation, taking down and rehanging doors

F100052 2mm aluminium or galvanised iron sheeting on surface of doors m2 27.86


including pinning with non-ferrous nails

BW-F5
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Door repairs (Cont'd)

Replacing one side or both sides plywood (any thickness)


panels or solid wrought timber panels in windows, shutters
or doors including taking down, framing up and rehanging as
necessary, and removing panels off site (rate measured by
area of windows, shutters or doors) (Cont'd)
m2 31.20
F100053 2mm aluminium or galvanised iron sheeting including pinning with
non-ferrous nails, preparation of surfaces, taking down and
rehanging doors

F100054 0.5mm aluminium or galvanised iron sheeting on surface of doors m2 21.90


including pinning with non-ferrous nails

F100055 0.5mm aluminium or galvanised iron sheeting on surface of doors m2 24.80


including pinning with non-ferrous nails, preparation, taking down
and rehanging doors

F100056 0.8mm aluminium or galvanised iron sheeting on surface of doors m2 24.95


including pinning with non-ferrous nails

F100057 0.8mm aluminium or galvanised iron sheeting on surface of doors m2 27.90


including pinning with non-ferrous nails, preparation, taking down
and rehanging doors

Stainless steel linings fixed to new or existing surfaces of


doors, partitions including preparation of surfaces, taking
down and rehanging doors

F100058 1 mm thick
m2 136.55
F100059 2 mm thick m2 168.10

F100060 3 mm thick m2 199.18

Fitments

F100061 Taking out existing counters, kitchen cabinets, etc and removing m 5.90
off site

F100062 Taking out existing counters (any type)/ kitchen cabinets and m 7.30
removing off site

F100063 Repairing to existing counters, kitchen sink cabinets and the like not m 42.60
exceeding 1 metre wide by replacing short lengths of damaged
timbers, plywood or plastic laminated lining not exceeding 0.50 m2
per spot and recramping drawers or doors. (short length not
exceeding 750 mm long)

BW-F6
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Fitments (Cont'd)
F100064 m2 3.50
Taking out existing counter tops, removing off site and preparing
surfaces to receive new
F100065 m2 28.00
Repair to existing cabinet, wardrobe, counter, etc including
stripping the existing veneer lining and prepare surface to receive
new finishes
F100066 m 35.00
Dismantle existing cabinet, wardrobe, counter, etc and reinstall to
new location

F100067 no 37.05
Make opening (any size) in new or existing counter top for sit-in
sink including additional bearers and makng good

Noticeboards, chalkboards

F100068 Taking out only existing chalkboards, white boards or noticeboards No 7.70
(any size), stack aside or removing off site and making good
surround

F100069 Taking out only existing chalkboards, white boards or noticeboards No 17.80
(any size), and refixing including providing new fasteners and
making good surround

Timber pelmets

F1 00070 Taking out existing pelmets and removing off site m 1.80

Curtains and blinds


F100071 No 15.10
Replacing magic baton for venetian blind (taking down and refixing
blind measured separately)

Chicks/blinds
F100072 m2 2.30
Taking down and carting away chicks, venetian blinds or vertical
blinds and making good to disturbed work (any size)
F100073 set 1.10
Take down existing venetian blinds including brackets and cut
away off site

F100074 Take down and cart away chicks and make good to work disturbed no 3.20
(any size)
F100075 m2 6.40

Taking down existing chicks or venetian blinds, repairing and


refixing including replacing new ropes or nylon chord, pulleys,
cleats, etc as necessary but excluding painting and linings

BW-F7
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Chicks/blinds (Cont'd)

F100076 Take down existing venetian blinds, repair without replacing any m2 3.90
accessories and refix

F100077 Take down existing venetian blinds, repair and refix including set 13.20
replacing the necessary cord lock, ladder cord, string, tilter rod etc
(not more than three (3) components for each set)

F100078 Without taking down existing venetian blinds, repair and refix set 2.80
including replacing the necessary cord lock, ladder cord, string,
tilter rod etc (not more than one (1) components for each set)

F100079 Take out as necessary, repair and refix the plastic chicks including m2 13.20
replacing all the necessary accessories

F100080 Take down existing chicks, repair new ropes or nylon chord, m2 8.70
pulleys, cleats, etc as necessary but excluding painting and lining

F100081 Taking down existing chicks, venetian blinds or vertical blinds and m2 3.80
refixing in position as directed

F1 00082 Rehang any set of venetian blinds set 2.20

m2 5.20
F100083 Take down existing chicks and refix only in new or same position
as directed

F100084 Ta ki n g d o wn exis ti n g ch ic ks o r ven e ti an bli n ds i nc lu di n g m2 6.50


shortening existing lengths and refixing

m2 9.65
F100085 Taking down existing chicks and refixing in position as directed
including cleaning down one side of existing chicks, reconditioning,
touching up with primer where chicks is exposed and applying one
undercoat and one finishing coat of enamel paint

F100086 Taking down existing chicks and refixing in positions as directed m2 14.27
including 2 coats of painting and replacing cloth lining on the other
side

F100087 6 mm diameter nylon rope


m 0.95
F100088 Replacing metal pulley for chicks (taking down and refixing chicks No 1.65
measured separately)

Curtain rails

F1 00089 Taking out existing curtain rails and carting away off site
m 0.60
F100090 Taking out existing curtain rails and refixing m 2.30

BW-F8
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 00000 DEMOLITION (CONT'D)

Sundries
F100091 m2 1.35
Taking out existing chicken wire netting in fence including any
framing or posts (any type) with foundations, removing off site and
including making good work disturbed
F100092 m2 1.20
Take down existing chicken wire netting, cart away from site or lay
aside for re-use

F100093 Taking from stack and fix only chicken wire netting m2 2.45
F100094 m2 1.40
Taking out existing weldmesh/netting and the like including or
excluding beadings, carting away from site and making good
surround
F100095 m2 0.80
Take out and cart away nylon fly-proof netting (14 mesh x 31
gauge) and prepare surrounds to receive new
F100096 m2 2.00
Take out existing weldmesh and the like including or excluding
beadings, carting away from site and making good surrounding
F100097 m2 2.27
Wiping down existing partition, ceiling (any type) etc with soap and
water

F100098 Removing existing timber or steel or stone tables, stools any size, No 18.68
etc and carting away off site including making good floor and wall
finishes to match existing

F200000 STRUCTURAL TIMBER

Sawn timber in carpentry work

F200001 Kempas m3 1,022.55

F200002 Keruing m3 1,188.68

F200003 Kapoh m3 1,278.60

F200004 Balau m3 1,435.50

F200005 Chengal m3 1,899.40

Wrought timber in carpentry work

F200006 Kempas m3 1,089.95

F200007 Keruing m3 1,185.80

F200008 Kapoh m3 1,540.05


BW-F9
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F200000 STRUCTURAL TIMBER (CONT'D)

Wrought timber in carpentry work (Cont'd)

F200009 Balau m3 1,850.87

F200010 Chengal m3 2,094.68

Add to above items (F200001) to (F20001 0) if in prefabricated roof


trusses for transporting, hoisting and fixing in position and
including bolts, screws, fixing plates, etc

F20001 1 Not exceeding 6 m high m3 183.90

F200012 Exceeding 6 m and not exceeding 9 m high m3 184.91

F200013 Exceeding 9 m and not exceeding 12 m high m3 202.25


F200014 m3 219.48
Add to above items (F200001) to (F200010) for fixing in repairing
to replace old and decayed timber, removing off site and including
all strutting, steel straps splicing etc and making good damaged or
missing timber
F200015 m3 108.80
Add to above items (F200001) to (F200010) if pressure impregnated
tmber is used

F200016 Add to above items (F200001) to (F200010) for pressure impregnated m3 66.15
timber with suitable wood preservative to an average dry salt
retention of 5.6kg/m2 and complying with SS 72 and treated in
accordance with SS CP 1

F300000 INSULATION

Fibreglass blankets or batts including extra labour dressing


insulation sheet over roof purlins, ceilings, partitions etc
(measured nett, no allowance made for laps)

F300001 50 mm thick (13 - 16 kg/m3 density) m2 7.70

F300002 50 mm thick (32 kg/m3 density) m2 9.10

F300003 50 mm thick (48 kg/m3 density) m2 16.35


F300004 m2 5.55
Add to above items (F300001) to (F300003) for laminated with
aluminium foil

BW-F10
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F300000 INSULATION (CONT'D)

Rock/mineral wool blankets or batts including extra labour


dressing insulation sheet over roof purlins, ceilings,
partitions etc (measured nett, no allowance made for laps)

F300005 25 mm thick (80 kg/m3 density) m2 9.29

F300006 25 mm thick (100 kg/m3 density) m2 8.80

F300007 50 mm thick (48 kg/m3 density) m2 12.09

F300008 50 mm thick (50 kg/m3 density) m2 10.50

F300009 50 mm thick (60 kg/m3 density) m2 12.53

F300009 50 mm thick (80 kg/m3 density) m2 16.31

F300010 50 mm thick (100 kg/m3 density) m2 18.00


F300011 m2 4.86
Add to above items (F300008) to (F300010) for laminated with
aluminium foil

Woodwool slabs pinned or screwed to bearers. (bearers


measured separately)

F300012 25 mm thick m2 17.30

F300013 50 mm thick m2 20.60

F300014 75 mm thick m2 28.75

Fire resistant aluminium foil; well lapped 150mm at joints,


including extra labour dressing over roof purlins, bearers of
ceilings, partitions, etc (measured nett, no allowance made
for laps)

F300015 Single-sided m2 2.27

F300016 Double-sided m2 4.75


F300017 m2 4.35
One layer of 'Sisalation 450' or other equal and approved double
sided, double reinforced fire resistant aluminium foil
F300018 m2 3.45
One layer of 'Sisalation 431' or other equal and approved double
sided, double reinforced fire resistant aluminium foil
F300019 m2 3.80
One layer of 'Sisalation 525' or other equal and approved double
sided, double reinforced fire resistant aluminium foil

F300020 m2 2.00
One layer of 'Sisalation 901' or other equal and approved single
sided, double reinforced fire resistant aluminium foil

BW-F11
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F300000 INSULATION (CONT'D)

Fire resistant aluminium foil; well lapped 150mm at joints,


including extra labour dressing over roof purlins, bearers of
ceilings, partitions, etc (measured nett, no allowance made
for laps) (Cont'd)

F300021 One layer of 'Thermofoil 750' or other equal and approved double m2 3.75
sided, reinforced aluminium foil

F300022 One layer of 'Thermofoil 731' or other equal and approved double m2 3.02
sided, reinforced aluminium foil

F300023 One layer of 'Thermofoil 600' or other equal and approved single m2 2.45
sided, reinforced aluminium foil

F400000 FLOORING

Teak parquetry flooring laid in pattern on prepared floor


surfaces with adhesive; including all cutting and sanding
(sealing and polishing measured separately)

F400001 12 mm thick
m2 48.94
F400002 20 mm thick m2 58.69

F400003 10mm thick teak parquet flooring fixed with adhesive including m2
sanding in skirting, plinths, upstands,etc including rounded top,
plugging and screed to walls (measured flat superficial unless
otherwise specified) (screed and polishing measured separately)

F400004 13mm thick teak parquet flooring fixed with adhesive including m2
sanding in skirting, plinths, upstands,etc including rounded top,
plugging and screed to walls (measured flat superficial unless
otherwise specified) (screed and polishing measured separately)

Wrought plain edge boarded floorings in 75mm or 100mm


widths fixed to timber including all cuttin g and sanding
(sealing and polishing measured separately)

F400005 19mm thick teak m2 167.24


F400006 25mm thick teak m2 206.93

F400007 19mm thick chengal m2 158.87

F400008 25mm thick chengal m2 196.56

BW-F12
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F400000 FLOORING (CONT'D)

Wrought tongued and grooved boarded floorings in 75mm or


100mm widths fixed to timber including all cutting and
sanding (sealing and polishing measured separately)

F400009 19mm thick teak m2 190.50

F400010 25mm thick teak m2 236.25

F40001 1 19mm thick chengal m2 62.15

F400012 25mm thick chengal m2 76.84

Air thrust flooring system comprising 150um clear polythene


vapour proof barrier; 70 x 45mm sawn pressure impregnated
timber floor battens; 9mm thick fully formed air cell resilient
pads and finished with 20mm thick tongued and grooved
flooring in 57mm width

F400013 Grade 1 maple m2 111.78

F400014 Grade 2 maple m2 101.84

F400015 18mm x 100mm high maple vented skirtings m 28.62

20mm thick cross-tongued, grooved and rebated threads and


risers with rounded nosings screwed together with and including
75 x 25mm sawn kapoh ground

F400016 Grade 1 maple 300mm wide treads m 155.30

F400017 Grade 2 maple 300mm wide treads m 147.20

F400018 Grade 1 maple 170mm high risers m 93.20


F400019 Grade 2 maple 300mm high risers m 85.10

F500000 BEARERS AND FRAMING

Beads, picture rails, skirtings, architraves, fillets, cornices


and the like in wrought timber including gluing and nailing

F500001 Kapoh not exceeding 500 mm2 sectional area m 6.48


F500002 m 2.16
Add to above items (F500001) for each additional increase of 500
mm2 sectional area

F500003 Chengal not exceeding 500 mm2 sectional area m 6.80


F500004 m 2.27
Add to above items (F500003) for each additional increase of 500
mm2 sectional area

BW-F13
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F500000 BEARERS AND FRAMING (CONT'D)

Beads, picture rails, skirtings, architraves, fillets, cornices


and the like in wrought timber including gluing and nailing
(Cont'd)

F500005 Teak not exceeding 500 mm2 sectional area m 7.56


F500006 m 2.60
Add to above items (F500005) for each additional increase of 500
mm2 sectional area

F500007 Remin not exceeding 500 mm2 sectional area m 5.45


F500008 m 0.80
Add to above items (F500007) for each additional increase of 500
mm2 sectional area

F500009 m 0.50
Add to any of above items (F500001) to (F500007) for pressure
impregnated

Frames, head, mullions, transomes, studs, sills fitments, joinery,


and the like in wrought timber worked to the required shapes
including forming grooves, rebates, throats, weathered
edges etc
(Frame not exceeding 2,000 sq mm cross-sectional area)

F500010 Ramin m 7.25

F500011 Kapur m 6.90

F500012 Chengal m 7.75

F500013 Balau m 6.90

(Frame exceeding 2,000 sq mm and not exceeding 4,000 sq


mm cross-sectional area)

F500014 Ramin m 11.05

F500015 Kapur m 9.40

F500016 Chengal m 11.10

F500017 Balau m 10.20

(Frame exceeding 4,000 sq mm and not exceeding 6,000 sq


mm cross-sectional area)

F500018 Ramin m 16.30

F500019 Kapur m 13.95

BW-F14
F : CARPENTRY & JOINERY
F500020 Chengal m 17.75

BW-F15
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F500000 BEARERS AND FRAMING (CONT'D)

(Frame exceeding 4,000 sq mm and not exceeding 6,000 sq


mm cross-sectional area) (Cont'd)

F500021 Balau m 16.85

(Frame exceeding 6,000 sq mm cross-sectional area)

F500022 Ramin m 20.05

F500023 Kapur m 21.95

F500024 Chengal m 26.15

F500025 Balau m 24.10

F500026 Add to any above items if pressure impregnated m 0.60

Frames, head, mullions, transomes, studs, sills fitments, joinery,


and the like per 1,000 mm2 sectional area in wrought timber
worked to the required shapes including forming grooves,
rebates, throats, weathered edges etc

F500027 Kapoh m 4.20

F500028 Balau m 3.89

F500029 Chengal m 6.15

F500030 Teak m 8.86

Sawn kapoh stud partition framing fixed at 600mm centres


bothways

F500031 50 x 50mm cross section m2 22.03

F500032 50 x 75mm cross section m2 26.46

Supply and install standard partition not exceeding 4,000 sq


mm in sectional area fixed at 600mm centre both ways (lining
measured separately)

F500033 Kapur m2 14.25

F500034 Chengal m2 20.35

Supply and install standard partition exceeding 4,000 sq mm


and not exceeding 6,500 sq mm in sectional area fixed at
600mm centre both ways (lining measured separately)

F500035 Kapur m2 17.15

F500036 Chengal m2 27.20

BW-F16
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F500000 BEARERS AND FRAMING (CONT'D)

Cut out lengths of framing to existing doors, windows,


partitions, studding, staircases, joinery, fitments, etc
removing off site, and where necessary preparing cut
surfaces to receive new

F500017 Not exceeding 2000 mm2 cross-sectional area m 2.30


F500017 m 3.00
Exceeding 2000 mm2 and not exceeding 4000 mm2 cross -
sectional area

F500017 Exceeding 4000 mm2 cross-sectional area m 3.50

F600000 WALL LININGS

Calcium silicate board reinforced with cellulose for


INTERNAL USE only and including fixing to bearers (Bearers
measured separately)

F600001 6 mm thick m2 16.20

F600002 9 mm thick m2 21.30

F600003 12 mm thick m2 26.70

F600004 15 mm thick m2 53.70

Calcium silicate board reinforced with selected fibres and


fillers for INTERNAL AND EXTERNAL USE and including
fixing to bearers (Beares measured separately)

F600005 4.5 mm thick m2 25.70

F600006 6 mm thick m2 33.30

F600007 9 mm thick m2 51.20

F600008 12 mm thick m2 92.55

Top gradefibre resistance calcium silicate board reinforced


with selected fibres and fillers for INTERNAL USE and
including fixing to bearers (Beares measured separately)

F600009 6 mm thick m2 24.65

F600010 9 mm thick m2 31.45

F600011 12 mm thick m2 38.20

BW-F17
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F600000 WALL LININGS (CONT'D)

Calcium silicate board reinforced with selected fibres and


fillers (Class 0) sheeting fixed to timber framing including
pointing

F600012 6 mm thick m2 19.98

F600013 9 mm thick m2 22.46

F600014 12 mm thick m2 24.95

Fibre cement board sheeting fixed to timber framing including


jointing compound, paper tape where necessary

F600015 4.5 mm thick m2 17.60

F600016 6 mm thick m2 16.70

F600017 9 mm thick m2 25.65

F600018 12 mm thick m2 25.90


F600019 m 1.60
Extra over above items (F600015) to (F600018) for corner
metal/plastic angles

Top grade fire-resistance fibre-reonforced cement building


board fixed to bearers (Bearers measured separately)

F600020 6 mm thick m2 14.55

F600021 9 mm thick m2 19.95

F600022 12 mm thick m2 24.10

Cement building board fixed to bearers (Bearers measured


separately)

F600023 6 mm thick m2 14.40

F600024 8 mm thick m2 15.65

F600025 10 mm thick m2 17.10

F600026 12 mm thick m2 20.15

F600027 16 mm thick m2 25.80

F600028 18 mm thick m2 32.10

F600029 24 mm thick m2 37.80

BW-F18
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F600000 WALL LININGS (CONT'D)

Bare finish gypsum board sheeting fixed to timber framing


including jointing compound, paper tape where necessary

F600030 10 mm thick m2 13.17

F600031 13 mm thick m2 15.30

F600032 16 mm thick m2 21.28


F600033 m2 226.90
2mm thick lead sheet lining covered with and including laminated
gypsum board

Plain grade plywood fixed to timber framing

F600034 4 mm thick m2 5.45

F600035 6 mm thick m2 6.95

F600036 9 mm thick m2 9.65

Cement building board fixed to bearers (Bearers measured


separately)

F600037 12 mm thick m2 13.47

F600038 15 mm thick m2 14.25

F600039 18 mm thick m2 15.40

F600040 25 mm thick m2 20.05


F600041 m2 11.34
Extra over above items (F600037) to (F600041) for sliced cut
veneers

Waterproof plywood fixed to timber framing

F600042 4 mm thick m2 6.60

F600043 6 mm thick m2 10.34

F600044 9 mm thick m2 12.48

F600045 12 mm thick m2 13.94

F600046 15 mm thick m2 15.40

F600047 18 mm thick m2 19.28

F600048 25 mm thick m2 20.80

BW-F19
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F600000 WALL LININGS (CONT'D)

Marine plywood fixed to timber framing

F600049 4 mm thick m2 11.88

F600050 3 mm thick m2 13.20

F600051 6 mm thick m2 18.55

F600052 9 mm thick m2 26.46

F600053 12 mm thick m2 28.44

F600054 15 mm thick m2 35.90

F600055 18 mm thick m2 44.70

F600056 25 mm thick m2 57.60


F600057 m2 6.60
Decorative vinyl or veneer (any thickness) to gypsum board,
plywood, etc)

Laminated plastic sheeting complying to BS 3796 glued to


timber surfaces with compatible adhesive including preparing
surfaces

F600058 0.80mm thick m2 18.96

F600059 1.00 mm thick m2 19.30

F600060 1.30 mm thick m2 24.22


1mm thick decorative steel plate formica fixed to timber surfaces m2 88.25
with approved adhesive compound including preparing surface

F700000 PARTITIONS

Toilet partitions
F700001 m2 #REF!
Toilet compartment consisting of 12 mm thick s olid compact
laminate (phenolic core) finished with melamine on both sides

F700002 Supply and install approved toilet compartment consisting of m2 225.65


10mm thick solid compact laminate finished with melamine on
both sides c/w stainless steel leg supports etc (colour of lamination
to be approved)

F700003 Supply and install approved toilet compartment consisting of m2 308.00


13mm thick solid compact laminate finished with melamine on
both sides c/w stainless steel leg supports etc (colour of lamination
BW-F20
F : CARPENTRY & JOINERY
to be approved)

BW-F21
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F700000 PARTITIONS (CONT'D)

Toilet partitions (Cont'd)

F700004 Doors consisting of 12 mm thick solid compact laminate finished m2 234.68


with melamine on both sides and complete with stainless steel leg
supports, heavy duty gravity hinges, indicator bolt, aluminium
trimming, etc

F700005 Supply and install door consisting of 10mm thick solid compact m2 242.65
laminate finished with melamine on both sides c/w stainless steel
leg supports, heavy duty gravity hinges, indicator bolt, aluminium
trimmings etc

F700006 Supply and install door consisting of 13mm thick solid compact m2 326.70
laminate finished with melamine on both sides c/w stainless steel
leg supports, heavy duty gravity hinges, indicator bolt, aluminium
trimmings etc

F700007 Standard size toilet compartment (average of 1 .80m deep and Per 2,160.00
1.80m high) consisting of 12 mm thick solid compact laminate Cubicle
(phenolic core) finished with melamine on both sides including
doors consisting of 12 mm thick solid compact laminate finished
with melamine on both sides and complete with stainless steel leg
supports, heavy duty gravity hinges, indicator bolt, aluminium
trimming, etc

F800000 WINDOWS AND DOORS

Note:
Rates for doors, casements and shutters excludes frames,
glazing, wire gauze and ironmongery

Ledged and braced shutters or doors with 19 mm butt jointed


boarding on 19mm ledges and braces hung in frames

F800001 Sawn kapoh m2 60.30


m2 74.10
F800002 W rought kapoh

Wrought framed, ledged and braced shutters or doors (partly


glazed if necessary) comprising of tongued, grooved and v-
jointed to match boarding fixed to frames, ledges and braces
to make up the total thickness stated in the schedule below
including hanging onto door frames

F800003 25 mm thick chengal m2 121.25


m2 143.44
F800004 38 mm thick chengal

BW-F22
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F800000 WINDOWS AND DOORS (CONT'D)

Wrought framed, ledged and braced shutters or doors (partly


glazed if necessary) comprising of tongued, grooved and v-
jointed to match boarding fixed to frames, ledges and braces
to make up the total thickness stated in the schedule below
including hanging onto door frames (Cont'd)

F800005 44 mm thick chengal m2 153.18

F800006 50 mm thick chengal m2 157.47

F800007 25 mm thick kapoh m2 85.47

F800008 38 mm thick kapoh m2 97.66

F800009 43 mm thick kapoh m2 96.91

F800010 44 mm thick kapoh m2 119.90

F80001 1 48 mm thick kapoh m2 106.90

F800012 50 mm thick kapoh m2 129.80

Wrought framed, ledged and braced shutters or doors (partly


glazed if necessary) comprising of butt jointed boarding fixed
to frames, ledges and braces to make up the total thickness
stated in the schedule below including hanging on to door
frames

F800013 25 mm thick chengal m2 110.85

F800014 38 mm thick chengal m2 127.10

F800015 43 mm thick chengal m2 109.40

F800016 44 mm thick chengal m2 154.00

F800017 48 mm thick chengal m2 113.30

F800018 50 mm thick chengal m2 158.40

F800019 25 mm thick kapoh m2 69.85

F800020 38 mm thick kapoh m2 86.20

F800021 43 mm thick kapoh m2 75.70

F800022 44 mm thick kapoh m2 107.80

F800023 48 mm thick kapoh m2 82.70

F800024 50 mm thick kapoh m2 117.70

BW-F23
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F800000 WINDOWS AND DOORS (CONT'D)

Casement or door in panels open to receive glass, waterproof


plywood or wire gauze with rebated and moulded rails, stiles,
glazing or dividing bars and pinned heads including hanging
on to door frames (Note : Infill panels of glass/plywood/wire
gauze, etc

F800025 25 mm thick chengal m2 78.10

F800026 38 mm thick chengal m2 88.85

F800027 43 mm thick chengal m2 76.60

F800028 44 mm thick chengal m2 108.90

F800029 48 mm thick chengal m2 79.90

F800030 50 mm thick chengal m2 113.40

F800031 25 mm thick kapoh m2 62.90

F800032 38 mm thick kapoh m2 69.90

F800033 43 mm thick kapoh m2 60.40

F800034 44 mm thick kapoh m2 86.90

F800035 48 mm thick kapoh m2 63.80

F800036 50 mm thick kapoh m2 91.30


Panelled casements or doors partly panelled with solid timber
or plywood not exceeding 12 mm thick partly open for glazing
with rebated and moulded rails stiles, glazing beads including
hanging on to door frames (glass panel measured separately)

F800037 25 mm thick chengal m2 96.50

F800038 38 mm thick chengal m2 100.50

F800039 43 mm thick chengal m2 86.80

F800040 44 mm thick chengal m2 123.20

F800041 48 mm thick chengal m2 91.90

F800042 50 mm thick chengal m2 129.80

F800043 25 mm thick kapoh m2 70.75

F800044 38 mm thick kapoh m2 84.43

BW-F24
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F800000
WINDOWS AND DOORS (CONT'D)

Panelled casements or doors partly panelled with solid timber


or plywood not exceeding 12 mm thick partly open for glazing
with rebated and moulded rails stiles, glazing beads including
hanging on to door frames (glass panel measured separately)

F800045 43 mm thick kapoh m2 84.70

F800046 44 mm thick kapoh m2 96.80

F800047 48 mm thick kapoh m2 91.35

F800048 50 mm thick kapoh m2 101.20

Louvred casements or doors comprising of twice splayed


louvres fixed at an angle of 60 degrees and not more than 40
mm apart and rebated and moulded rails and stiles including
handing onto door frames

F800049 38 mm thick chengal m2 99.13

F800050 43 mm thick chengal m2 100.90

F800051 44 mm thick chengal m2 117.70

F800052 48 mm thick chengal m2 85.90

F800053 50 mm thick chengal m2 122.10

F800054 38 mm thick kapoh m2 62.23

F800055 43 mm thick kapoh m2 56.95

F800056 44 mm thick kapoh m2 92.40

F800057 48 mm thick kapoh m2 65.50

F800058 50 mm thick kapoh m2 93.50

Hollow flush doors complying with BS 459 comprising of


kapoh skeleton framing and lippings all round including
hanging on to door frames

F800059 m2 45.20
21 mm thick covered on both sides with 4 mm thick waterproof
plywood

F800060 m2 62.95
27 mm thick covered on both sides with 4 mm thick waterproof
plywood

F800061 m2 69.50
31 mm thick covered on both sides with 6 mm thick waterproof
plywood

BW-F25
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F800000 WINDOWS AND DOORS (CONT'D)

Hollow flush doors complying with BS 459 comprising of


kapoh skeleton framing and lippings all round including
hanging on to door frames (Cont'd)

F800062 40 mm thick covered on both sides with 6mm thick waterproof m2 99.00
plywood

F800063 43 mm thick covered on both sides with 9mm thick waterproof m2 110.10
plywood

F800064 38 mm thick covered on both sides with 6mm thick plywood m2 74.30

F800065 48 mm thick covered on both sides with 6mm thick plywood m2 80.35
m2 76.20
F800066 38 mm thick covered on both sides with 6mm thick waterproof
plywood
m2 84.57
F800067 48 mm thick covered on both sides with 6mm thick waterproof
plywood

F800068 38 mm thick covered on both sides with 6mm thick plywood m2 102.49
including fixed aluminium louvres

F800069 48 mm thick covered on both sides with 6mm thick plywood m2 105.78
including fixed aluminium louvres

F800070 38 mm thick covered on both sides with 6mm thick waterproof m2 178.31
plywood including fixed aluminium louvres

F800071 48 mm thick covered on both sides with 6mm thick waterproof m2 185.33
plywood including fixed aluminium louvres

F800072 37 mm thick covered on both sides with 6mm thick waterproof m2 92.40
plywood including fixed aluminium louvres

F800073 43 mm thick covered on both sides with 9mm thick waterproof m2 96.80
plywood including fixed aluminium louvres

F800074 48 mm thick covered on both sides with 9mm thick waterproof m2 100.50
plywood including fixed aluminium louvres

F800075 Extra over for above items for constructing fixed aluminium louvre m2 11.60

F800076 Extra over for above items for glazed peephole m2 6.90
m2 63.90
F800077 38 mm thick covered on both sides with 6mm thick plywood
including glazed observation panels

F800078 48 mm thick covered on both sides with 6mm thick plywood m2 78.60
including glazed observation panels

BW-F26
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F800000 WINDOWS AND DOORS (CONT'D)

Hollow flush doors complying with BS 459 comprising of


kapoh skeleton framing and lippings all round including
hanging on to door frames (Cont'd)

F800079 38 mm thick covered on both sides with 6mm thick waterproof m2 201.85
plywood including glazed observation panels

F800080 48 mm thick covered on both sides with 6mm thick waterproof m2 208.87
plywood including glazed observation panels

F800081 38 mm thick covered on both sides with 6mm thick plywood m2 76.60
including glazed observation panels and fixed aluminium louvres

F800082 48 mm thick covered on both sides with 6mm thick plywood m2 92.00
including glazed observation panels and fixed aluminium louvres

F800083 38 mm thick covered on both sides with 6mm thick waterproof m2 240.73
plywood including glazed observation panels and fixed aluminium
louvres

F800084 48 mm thick covered on both sides with 6mm thick waterproof m2 247.75
plywood including glazed observation panels and fixed aluminium
louvres

(Note: Rates will be pro-rated for other types of linings)

Semi-flush doors complying with BS 459 comprising of


hardwood skeleton framing and lippings all round including
hanging on to door frame

F800085 38 mm thick kapoh including rebated V-jointed panels


m2 86.53
F800086 39 mm thick kapoh including rebated V-jointed panels m2 109.80

F800087 48 mm thick kapoh including rebated V-jointed panels m2 100.05

F800088 38 mm thick chengal including rebated V-jointed panels m2 129.50

F800089 39 mm thick chengal including rebated V-jointed panels m2 167.50


m2 161.80
F800090 48 mm thick chengal including rebated V-jointed panels

Solid core flush doors complying with BS 459 comprising of


hardwood lippings around vertical core strips glued and well
cramped together with strengthening rods including hanging
on to door frames

F800091 38 mm thick kapoh covered on both sides with 6mm thick plywood m2 122.90

BW-F27
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F800000 WINDOWS AND DOORS (CONT'D)

Solid core flush doors complying with BS 459 comprising of


hardwood lippings around vertical core strips glued and well
cramped together with strengthening rods including hanging
on to door frames

F800092 48 mm thick kapoh covered on both sides with 6mm thick plywood m2 127.56

F800093 50 mm thick kapoh covered on both sides with 6mm thick plywood m2 147.80

F800094 38 mm thick chengal covered on both sides with 6mm thick m2 186.40
plywood

F800095 m2 169.70
48 mm thick chengal covered on both sides with 6mm thick
plywood
F800096 m2 219.50
50 mm thick chengal covered on both sides with 6mm thick
plywood

F800097 38 mm thick kapoh m2 110.60

F800098 48 mm thick kapoh m2 118.40

F800099 38 mm thick kapoh including glazed observation panels m2 110.97

F800100 48 mm thick kapoh including glazed observation panels m2 130.40

F800101 38 mm thick chengal m2 178.70

F800102 48 mm thick chengal m2 185.80

F800103 38 mm thick chengal including glazed observation panels m2 184.00

F800104 48 mm thick chengal including glazed observation panels m2 189.40

Timber fire-rated doors complying with SS 332 to meet Fire


Service Bureau Requirements, tested and inspected by PSB
and affixed with PSB's approval labels complete with fire
proofed lockset, stainless steel ball bearing hinges, flush
bolts, door closers

F800105 Half hour fire-rated single leaf m2 355.70

F800106 900 x 2100 x 45mm thick, single leaf, Polynorm 1/2 hour rated no 935.00

F800107 900 x 2100 x 46mm thick, single leaf, Pyropanel 1/2 hour rated no 990.00

BW-F28
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F800000 WINDOWS AND DOORS (CONT'D)

Timber fire-rated doors complying with SS 332 to meet Fire


Service Bureau Requirements, tested and inspected by PSB
and affixed with PSB's approval labels complete with fire
proofed lockset, stainless steel ball bearing hinges, flush
bolts, door closers (Cont'd)

F800108 One hour fire-rated single leaf m2 439.22

F8001 09 900 x 2100 x 48mm thick, single leaf, Pyropanel 1 hour rated no 1,285.00

F8001 10 1200 x 2100 x 48mm thick, single leaf, Pyropanel 1 hour rated no 1,493.80

F8001 11 Two hour fire-rated single leaf m2 569.20

F8001 12 900 x 2100 x 48mm thick, single leaf, Pyropanel 1 hour rated no 1,417.90

F8001 13 1200 x 2100 x 48mm thick, single leaf, Pyropanel 1 hour rated no 1,645.60

F8001 14 Half hour fire-rated double equal leaves m2 380.10

F8001 15 Half hour fire-rated double unequal leaves m2 344.25


F800116 no 1,628.00
1200 x 2100 x 45mm thick, double unequal leaf, Polynorm 1/2
hour rated
F800117 no 1,265.00
1200 x 2100 x 48mm thick, double unequal leaf, Pyropanel 1/2
hour rated

F8001 18 One hour fire-rated double equal leaves m2 364.50

F8001 19 One hour fire-rated double unequal leaves m2 409.05

F800120 Two hour fire-rated double equal leaves m2 396.90

F800121 Two hour fire-rated double unequal leaves m2 445.50


F800122 Labour only to form observation panels (any size and shapes) No 34.73
including necessary glass and beading in doors

F900000 SLATTED PANELS

F900001 m2 23.90
Slatted panels consisting of kapoh battens not exceeding 500
mm2 sectional area fixed not more than 20 mm apart on timber
bearers (bearers measured separately)

F900002 m2 18.80
Slatted panels consisting of kapoh battens not exceeding 500
mm2 sectional area fixed not more than 20 mm apart on and
including 6 mm thick plywood backing

BW-F29
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F900000 SLATTED PANELS (CONT'D)

F900003 m2 32.30
Slatted panels consisting of kapur battens not exceeding 1 000sq
mm sectional area fixed not more than 20mm apart on and
including 6mm thick plywood backing

F900004 Slatted panels consisting of on timber bearers (bearers measured m2 25.40


separately) not exceeding 1000sq mm sectional area fixed not
more than 20mm apart on and including 6mm thick plywood
backing

F1 000000 FITMENTS

Fitments fixed to walls and grouted onto concrete base or


timber supports including all necessary ironmongery

(Note: Fitments not mentioned herein shall be measured and


rate built-up accordingly)
F1000001 m 146.77
Teacher's workstation not exceeding 600mm wide and 750mm
high (Acid resistant polyester resin worktop measured separately)
(Cookery preparation room/store)

F1000002 Teacher's demonstration table not exceeding 600mm wide and m 123.55
900mm high (Acid resistant polyester resin worktop measured
separately) (Kitchen)

F1000003 Student's workbench not exceeding 600mm wide and 900mm high m 111.24
(Acid resistant polyester resin worktop measured separately)
(Kitchen)
F1000004 m 294.08
Long timber workbench not exceeding 600mm wide and 900mm
high (Acid resistant polyester resin worktop measured separately)
(Kitchen)

F1000005 Teacher's bench not exceeding 900mm wide and 900mm high m 345.92
(science laboratory) (acid resistant polyester resin worktop
measured separately) (Science laboratory)

F1000006 Student's bench not exceeding 900mm wide and 900mm high m 328.00
(science laboratory) (acid resistant polyester resin worktop
measured separately) (Science laboratory)

F1000007 Long workbench not exceeding 900mm wide and 900mm high m 291.92
(Acid resistant polyester resin worktop measured separately)
(Science Laboratory)
F1000008 F1000009
Workbench with high storage cabinet not exceeding 900mm wide Workbench
and 2100mm high (Staff workroom) with sink
not
BW-F30
F : CARPENTRY & JOINERY
exceeding 900mm wide and 2100mm high (Solid surfacing m 479.95
material counter top and sink measured separately) (Staff
workroom)
m 333.61

BW-F31
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Fitments fixed to walls and grouted onto concrete base or


timber supports including all necessary ironmongery (Cont'd)

(Note: Fitments not mentioned herein shall be measured and


rate built-up accordingly)

F1000010 m 333.61
Workbench with sink not exceeding 900mm wide and 2100mm
high (Solid surfacing material counter top and sink measured
separately) (Staff workroom)

F1000011 Student's bench, island bench with three sinks not exceeding m 660.85
1650mm wide and 900mm high (science laboratory) (acid resistant
polyester resin worktops and sinks measured separately) (Science
laboratory)

F1000012 m 209.95
Timber counter cabinet not exceeding 600mm wide and 750mm
high (Bookshop)

F1000013 m 134.35
Display cabinet type 'F' not exceeding 600mm wide and 750mm
high (Needlework room)

F1000014 Resource counter not exceeding 600mm wide and 900mm high m 145.04
(Kitchen)
F1000015 m 337.61
Wall hung display cabinet not exceeding 600mm wide and 900mm
high (concrete top and sink measured separately) (Cookery
preparation room/store)

F1000016 Media island for 3 terminals not exceeding 600mm wide and m 728.35
1050mm high (Media resource library)

F1000017 Timber counter not exceeding 600mm wide and 1200mm high m 458.35
(General office)
F1000018 m 656.32
Book chute not exceeding 600mm wide and 1200mm high (Media
resource library)

F1000019 Enclosed rifle rack not exceeding 600mm wide and 1500mm high m 212.54
(Armoury)

F1000020 Dressing table and mirror not exceeding 600mm wide and m 326.38
1650mm high (Multi-purpose hall changing room)
F1000021 m 735.60
Non-print media cabinet not exceeding 600mm wide and 2100mm
high (Media resource library)

BW-F32
F : CARPENTRY & JOINERY
F1000022 Music rack and cabinets for band instruments not exceeding m 390.85
600mm wide and 2100mm high (Music store)

BW-F33
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Fitments fixed to walls and grouted onto concrete base or


timber supports including all necessary ironmongery (Cont'd)

(Note: Fitments not mentioned herein shall be measured and


rate built-up accordingly)

F1000023 Music rack and cabinets for curriculum music not exceeding m 503.39
600mm wide and 2100mm high (Music store)
F1000024 m 278.32
AV equipment worktop not exceeding 750mm wide and 750mm
high (Media resource library)

F1000025 Circulation counter not exceeding 750mm wide and 750mm high m 527.80
(Media resource library)

F1000026 Single seat computer table not exceeding 750mm wide and m 177.55
750mm high (Media resource library)

F1000027 Double seat computer table not exceeding 750mm wide and m 177.55
750mm high (Media resource library)
F1000028 m 220.75
Low cabinet not exceeding 600mm wide and 900mm high (Casting
room)
F1000029 m 220.75
Low cabinet not exceeding 600mm wide and 900mm high (Art
store)

F1000030 Low cabinet not exceeding 600mm wide and 900mm high m 145.15
(Kitchen)
F1000031 m 313.85
Timber cabinet with wall hung display not exceeding 600mm wide
and 900mm high (Concrete top and sink measured separately)
(Cookery preparation room/store)

F1000032 Low timber cabinet not exceeding 600mm wide and 900mm high m 209.95
(Printing, Meeting, Health & Fitness, Career guidance rooms,
AVA/Dance store)
F1000033 m 270.00
Timber cabinet with sink not exceeding 600mm wide and 900mm high
( Solid surfacing material counter top measured separately)
(Staff lounge)
F1000034 m 223.24
Low timber cabinet with timber shelves not exceeding 600mm
wide and 1050mm high (Casting room)
F1000035 m 222.05
Timber cabinet not exceeding 750mm wide and 750mm high (Acid
resistant polyester resin worktop measured separately) (Cookery
preparation room/store)

BW-F34
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Fitments fixed to walls and grouted onto concrete base or


timber supports including all necessary ironmongery (Cont'd)

(Note: Fitments not mentioned herein shall be measured and


rate built-up accordingly)

F1000036 Concrete counter with cabinet not exceeding 750mm wide and m 195.48
900mm high (Concrete top measured separately) (Design and
technology workshop)

F1000037 Timber drill bench with cabinets not exceeding 750mm wide and m 314.39
900mm high (Design and technology workshop)

F1000038 Low timber cabinet not exceeding 750mm wide and 900mm high m 220.75
(Art & crafts room)

F1000039 Low timber cabinet not exceeding 750mm wide and 900mm high m 296.35
(Acid resistant polyester resin worktop measured separately)
(Kitchen)

F1000040 Low concrete top cabinet with sink not exceeding 750mm wide and m 188.14
900mm high (Concrete top and sink measured separately) (Art &
crafts, project rooms)
F1000041 m 296.24
Low timber cabinet with timber shelves not exceeding 750mm
wide and 1050mm high (Project room)

F1000042 m 178.50
Low cabinet not exceeding 900mm wide and 900mm high (Acid
resistant polyester resin worktop measured separately) (Science
laboratory)

F1000043 High timber cabinet and wall hung display cabinet not exceeding m 361.20
600mm wide and 1350mm high (Acid resistant polyester resin
worktop measured separately) (Cookery preparation room/store)
F1000044 m 177.55
Microscope cupboard not exceeding 600mm wide and 1200mm
high (Science laboratory)

F1000045 Timber cabinet with built-in safe not exceeding 750mm wide and m 421.63
2100mm high (R.C. Support & safe measured separately)
(Principal's office)

F1000046 High timber cabinet not exceeding 600mm wide and 2100mm high m 436.75
(Art & crafts room)

F1000047 Timber cabinet not exceeding 600mm wide and 1250mm high m 221.94
(Acid resistant polyester resin worktop measured separately)
high
F1000048 (Science
Timber storage cabinet not exceeding 600mm wide and 2100mm
BW-F35
F : CARPENTRY & JOINERY
preparation room/store) m 424.60

BW-F36
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Fitments fixed to walls and grouted onto concrete base or


timber supports including all necessary ironmongery (Cont'd)

(Note: Fitments not mentioned herein shall be measured and


rate built-up accordingly)

F1000049 Timber cabinet not exceeding 600mm wide and 2250mm high m 415.15
(Needlework room)

F1000050 m 422.39
High timber cupboard not exceeding 600mm wide and 2250mm
high (Needlework room)

F1000051 High timber cabinet not exceeding 600mm wide and 2250mm high m 415.15
(Cookery preparation room/store)

F1000052 High storage with whiteboard & pin-up board not exceeding m 410.40
600mm wide and 2400mm high (Mother tongue language,
Geography, History AVA/Dance, Computer Lab & IT Resource,
Commerce, Music, Art & Craft rooms)

F1000053 High timber cabinet not exceeding 600mm wide and 2550mm high m 418.61
(Non-teaching staff room, Games equipment store)

F1000054 Two-tier cabinet and wall hung storage cabinet not exceeding m 386.32
900mm wide and 2100mm high (Acid resistant polyester resin
worktop measured separately) (Science preparation room/store)
F1000055 m 227.02
Two-tier open rifle rack not exceeding 600mm wide and 2700mm
high (Armoury)

F1000056 Open timber shelves not exceeding 750mm wide and 750mm high m 328.75
(Librarian's workroom)

F1000057 Timber shelves not exceeding 600mm wide and 2100mm high m 494.32
(General office)

F1000058 Timber shelves not exceeding 600mm wide and 1200mm high m 220.75
(Needlework room)
F1000059 m 458.35
Open timber shelves not exceeding 600mm wide and 2100mm
high (Office, AVA/dance store)

F1000060 High timber open shelves not exceeding 600mm wide and m 422.39
2100mm high (Bookshop)

F1000061 High timber open shelves not exceeding 600mm wide and m 398.41
2550mm high (Games equipment store)

BW-F37
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Fitments fixed to walls and grouted onto concrete base or


timber supports including all necessary ironmongery (Cont'd)

(Note: Fitments not mentioned herein shall be measured and


rate built-up accordingly)

F1000062 Extra over counters, kitchen cabinets, built-in cupboards, and the m 92.40
like the rates of which are built-up against the break down items
for extra handling, transportation, prefabrication, etc (length of
fitments measured irrespective of width and height)

F1000063 12mm thick approved acid resistant polyes ter resin worktops m2 427.70
50mm high backsplash, 40mm front edge mounted on fitments
including sealing joints between worktops and walls with matching
sealants (measured area on plan)

F1000064 12mm thick approved acid resistant epoxy resin worktops 50mm m2 475.20
high backsplash, 40mm front edge mounted on fitments including
sealing joints between worktops and walls with matching sealants
(measured area on plan)

F1000065 19mm Standard postformed shelf with 40mm edges complete with m 48.70
fixing accessories not exceeding 300mm wide

F1000066 12mm Solid surfacing shelf with 40mm edges complete with fixing m 75.60
accessories not exceeding 300mm wide

Drawers consisting of 19 mm front, 13 mm sides and back


and butt jointed bottom, all dovetailed housed and glued
together to a depth not exceeding 75 mm internally and the
bottom shall be 9 mm thick plywood. The internal and
external finishes shall be painted or finished with laminated
plastic

F1000067 Chengal drawers not exceeding 0.10 m2 internal area


No 12.70
No 17.40
F1000068 Chengal drawers exceeding 0.10 m2 and not exceeding 0.20 m2
internal area

F1000069 Chengal drawers exceeding 0.20 m2 and not exceeding 0.30 m2 No 18.63
internal area

F1000070 Add for each addition 0.10 m2 in area for chengal drawers No 4.30

F1000071 Kapoh drawers not exceeding 0.10 m2 internal area No 8.91

No 13.40
F1000072 Kapoh drawers exceeding 0.10 m2 and not exceeding 0.20 m2
internal area

BW-F38
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Drawers consisting of 19 mm front, 13 mm sides and back


and butt jointed bottom, all dovetailed housed and glued
together to a depth not exceeding 75 mm internally and the
bottom shall be 9 mm thick plywood. The internal and
external finishes shall be painted or finished with laminated
plastic (Cont'd)

F1000073 Kapoh drawers exceeding 0.20 m2 and not exceeding 0.30 m2 No 14.58
internal area

F1000074 Add for each additional 0.10 m2 in area for kapoh drawer No 3.30

F1 000075 Shaped drawers pull handle (any shape, length and type of timber) No 2.15
screwed to drawer front

F1000076 Drawers consisting of Teak timber 19 mm front, 13 mm sides and


No 41.50
back and butt jointed bottom, all dovetailed housed and glued
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Teak timber. The internal and external
finishes shall be painted or finished with laminated plastic with
internal area not exceeding 0.10sq m

F1000077 Drawers consisting of Teak timber 19 mm front, 13 mm sides and no 59.30


back and butt jointed bottom, all dovetailed housed and glued
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Teak timber. The internal and external
finishes shall be painted or finished with laminated plastic with
internal area exceeding 0.20sq m & not exceeding 0.30sq m

F1000078 Drawers consisting of Teak timber 19 mm front, 13 mm sides and


back and butt jointed bottom, all dovetailed housed and glued no 69.10
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Teak timber. The internal and external
finishes shall be painted or finished with laminated plastic with
internal area exceeding 0.20sq m & not exceeding 0.30sq m

F1000079 Add for each additional 0.10 m2 in area for teak drawer
No 13.00

F1000080 Add for each additional 75 mm in depth for teak drawer No 5.40

No 22.10
F1000081 Drawers consisting of plywood with Polyken 19 mm front, 13 mm
sides and back and butt jointed bottom, all dovetailed housed and
glued together to a depth of between 75 mm to 200mm internally
and the bottom shall be 9 mm thick plywood with Polyken. The
internal and external finishes shall be painted or finished with
laminated plastic with internal area exceeding 0.10sq m & not
exceeding 0.20sq m

BW-F39
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Drawers consisting of 19 mm front, 13 mm sides and back


and butt jointed bottom, all dovetailed housed and glued
together to a depth not exceeding 75 mm internally and the
bottom shall be 9 mm thick plywood. The internal and
external finishes shall be painted or finished with laminated
plastic (Cont'd)

F1000082 Drawers consisting of plywood with Polyken 19 mm front, 13 mm No 31.00


sides and back and butt jointed bottom, all dovetailed housed and
glued together to a depth of between 75 mm to 200mm internally
and the bottom shall be 9 mm thick plywood with Polyken. The
internal and external finishes shall be painted or finished with
laminated plastic with internal area exceeding 0.20sq m & not
exceeding 0.30sq m

F1000083 Drawers consisting of plywood with Polyken, 19 mm front, 13 mm No 36.80


sides and back and butt jointed bottom, all dovetailed housed and
glued together to a depth of between 75 mm to 200mm internally
and the bottom shall be 9 mm thick plywood with Polyken. The
internal and external finishes shall be painted or finished with
laminated plastic with internal area exceeding 0.20sq m & not
exceeding 0.30sq m

F1000084 Add for each additional 0.10 m2 in area for plywood with Polyken No 5.80
drawer

F1000085 Add for each additional 75 mm in depth for plywood with Polyken No 2.00
drawer

F1000086 Drawers consisting of Kapur timber 19 mm front, 13 mm sides and No 17.30


back and butt jointed bottom, all dovetailed housed and glued
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Kapur plywood. The internal and
external finishes shall be painted or finished with laminated plastic
with internal area not exceeding 0.10sq m

F1000087 Drawers consisting of Kapur plywood 19 mm front, 13 mm sides No 23.40


and back and butt jointed bottom, all dovetailed housed and glued
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Kapur plywood. The internal and
external finishes shall be painted or finished with laminated plastic
with internal area exceeding 0.10sq m & not exceeding 0.20sq m

F1000088 Drawers consisting of Kapur timber, 19 mm front, 13 mm sides no 28.20


and back and butt jointed bottom, all dovetailed housed and glued
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Kapur plywood. The internal and
external finishes shall be painted or finished with laminated plastic
with internal area exceeding 0.20sq m & not exceeding 0.30sq m

BW-F40
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 000000 FITMENTS (CONT'D)

Drawers consisting of 19 mm front, 13 mm sides and back


and butt jointed bottom, all dovetailed housed and glued
together to a depth not exceeding 75 mm internally and the
bottom shall be 9 mm thick plywood. The internal and
external finishes shall be painted or finished with laminated
plastic (Cont'd)

F1000089 Add for each additional 0.10 m2 in area for Kapur drawer
No 4.50
F1000090 Add for each additional 75 mm in depth for Kapur drawer No 0.70
no 13.90
F1000091 Drawers consisting of Dark Red Meranti, 19 mm front, 13 mm
sides and back and butt jointed bottom, all dovetailed housed and
glued together to a depth of between 75 mm to 200mm internally
and the bottom shall be 9 mm thick Dark Red Meranti plywood.
The internal and external finishes shall be painted or finished with
laminated plastic with internal area not exceeding 0.10sq m

F1000092 Drawers consisting of Dark Red Meranti 19 mm front, 13 mm sides no 19.00


and back and butt jointed bottom, all dovetailed housed and glued
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Dark Red Meranti plywood. The
internal and external finishes shall be painted or finished with
laminated plastic with internal area exceeding 0.10sq m & not
exceeding 0.20sq m

F1000093 Drawers consisting of Dark Red Meranti 19 mm front, 13 mm sides no 23.00


and back and butt jointed bottom, all dovetailed housed and glued
together to a depth of between 75 mm to 200mm internally and the
bottom shall be 9 mm thick Dark Red Meranti plywood. The
internal and external finishes shall be painted or finished with
laminated plastic with internal area exceeding 0.20sq m & not
exceeding 0.30sq m

F1000094 Add for each additional 0.10 m2 in area for Dark Red Meranti No 4.40
drawer

F1000095 Add for each additional 75 mm in depth for Dark Red Meranti No 0.70
drawer

F1 100000 NOTICE BOARDS, CHALKBOARDS

Coloured felt noticeboards pinned to wall complete with


softboard backing and with anodised aluminium frames
surround

F1100001 600 x 900mm


No 22.20
F1100002 900 x 1200mm No 44.50

BW-F41
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 100000 NOTICE BOARDS, CHALKBOARDS (CONT'D)

Coloured felt noticeboards pinned to wall complete with


softboard backing and with anodised aluminium frames
surround (Cont'd)

F1100003 900 x 1500mm No 55.50

F1100004 900 x 1800mm No 59.94

F1100005 1200 x 1500mm No 74.10

F1100006 1200 x 1800mm No 88.80

F1100007 1200 x 2400mm No 118.50

F1100008 Other sizes not stated in items (F1100001) to (F1100007) m2 41.10

Coloured felt noticeboards pinned to wall complete with


softboard backing and 3mm plywood backing and anodised
aluminium frames surround

F1100009 600 x 900mm No 66.00

F1100010 900 x 1200mm No 105.60

F1100011 900 x 1500mm No 121.00

F1100012 900 x 1800mm No 137.50

F1100013 1200 x 1500mm No 176.00

F1100014 1200 x 1800mm No 192.50

F1100015 1200 x 2400mm No 253.00

Coloured felt noticeboards pinned to wall complete with


softboard backing and with timber frames surround

F1100016 600 x 900mm No 13.77

F1100017 900 x 1200mm No 27.54

F1100018 900 x 1500mm No 38.30

F1100019 900 x 1800mm No 41.31

F1100020 1200 x 1500mm No 51.00

F1100021 1200 x 1800mm No 55.08

F1100022 1200 x 2400mm No 81.60

F1 100023 Other sizes not stated in items (F1 100016) to (F1 100022) m2 28.40

BW-F42
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 100000 NOTICE BOARDS, CHALKBOARDS (CONT'D)

Coloured felt noticeboards pinned to wall complete with


softboard backing and 3mm plywood backing and wooden
frames surround (thickness not exceeding 100mm)

F1100024 600 x 900mm No 37.40

F1100025 900 x 1200mm No 70.40

F1100026 900 x 1500mm No 88.00

F1100027 900 x 1800mm No 105.60

F1100028 1200 x 1500mm No 118.80

F1100029 1200 x 1800mm No 140.80

F1100030 1200 x 2400mm No 187.00

Coloured felt noticeboards pinned to wall complete with


softboard backing and with timber frames surround, sliding
glass panel and locks

F1100031 900 x 1200mm No 169.13

F1100032 900 x 1800mm No 253.69

F1100033 1200 x 2400mm No 451.01

Coloured felt noticeboards pinned to wall complete with


softboard backing and 3mm plywood backing and aluminium
frame backing and aluminium frames metal sliding tracks,
metal rollers, 5mm thick glass panels and glass lockset etc
(thickness not exceeding 100mm)

F1100034 600 x 900mm No 127.60

F1100035 900 x 1200mm No 189.20

F1100036 900 x 1500mm No 220.00

F1100037 900 x 1800mm No 246.40

F1100038 1200 x 1500mm No 270.60

F1100039 1200 x 1800mm No 310.20

F1100040 1200 x 2400mm No 391.60

BW-F43
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 100000 NOTICE BOARDS, CHALKBOARDS (CONT'D)

12mm Softboards faced noticeboard pinned to wall with


timber frames surround

F1100041 600 x 900mm No 18.10

F1100042 900 x 1200mm No 36.20

F1100043 900 x 1500mm No 43.94

F1100044 900 x 1800mm No 54.20

F1100045 1200 x 1500mm No 58.58

F1100046 1200 x 1800mm No 72.25

F1100047 1200 x 2400mm No 97.40

F1100048 Other sizes not stated in items (F1100041) to (F1100047) m2 16.20

12mm Softboards faced noticeboard pinned to wall with


natural anodised aluminium frames surround

F1100049 600 x 900mm No 25.10

F1100050 900 x 1200mm No 45.90

F1100051 900 x 1500mm No 58.45

F1100052 900 x 1800mm No 72.10

F1100053 1200 x 1500mm No 96.60

F1100054 1200 x 1800mm No 100.29

F1100055 1200 x 2400mm No 128.20

F1 100056 Other sizes not stated in items (F1 100049) to (F1 100055) m2 25.11

Pin boards consisting of 12mm thick softboard on 9mm thick


plywood backing board in fabric faced finish complete with
natural anodised aluminium frames with black moulded pvc
corner capping

F1100057 1200 x 1200mm No 90.72

F1100058 1350 x 1200mm No 105.62

F1100059 2400 x 1200mm No 162.76

BW-F44
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 100000 NOTICE BOARDS, CHALKBOARDS (CONT'D)

Pin boards consisting of 12mm thick softboard on 9mm thick


plywood backing board in fabric faced finish complete with
natural anodised aluminium frames with black moulded pvc
corner capping (Cont'd)

F1100060 3600 x 1200mm No 222.37

F1 100061 Other sizes not stated in items (F1 100057) to (F1 100060) m2 56.70

Chalk-boards on timber backing complete with chalk-ledges


and anodised aluminium frames surrounds

F1100062 600 x 900mm No 36.35

F1100063 900 x 1200mm No 72.65

F1100064 900 x 1500mm No 90.80

F1100065 900 x 1800mm No 109.00

F1100066 1200 x 1500mm No 121.85

F1100067 1200 x 1800mm No 145.35

F1100068 1200 x 2400mm No 194.50

F1100069 1200 x 3600mm No 290.65

F1 100070 Other sizes not stated in items (F1 100062) to (F1 100069) m2 57.20

Chalk-boards on timber backing complete with chalk-ledges


and timber frames surrounds

F1100071 600 x 900mm No 27.20

F1100072 900 x 1200mm No 55.50

F1100073 900 x 1500mm No 69.10

F1100074 900 x 1800mm No 83.20

F1100075 1200 x 1500mm No 92.65

F1100076 1200 x 1800mm No 111.50

F1100077 1200 x 2400mm No 148.65

F1100078 1200 x 3600mm No 223.00

F1 100079 Other sizes not stated in items (G1000047) to (G1000054) m2 43.70

BW-F45
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


F1 10000 0 NOTICE BOARDS, CHALKBOARDS (CONT'D)
(S$)
Wall mounted magnetic whiteboard complete with anodised
aluminium frames and penledges (laminated)

F1100080 600 x 900mm


No 27.30
F1100081 900 x 1200mm No 55.15

F1100082 900 x 1500mm No 72.10

F1100083 900 x 1800mm No 86.30

F1100084 1200 x 1500mm No 98.35

No 116.35
F1100085 1200 x 1800mm
No 157.35
F1100086 1200 x 2400mm
No 236.00
F1100087 1200 x 3600mm

F1 100088 Other sizes not stated in items (F1 100080) to (F1 m2 48.20
100087)

Wall mounted magnetic whiteboard complete with anodised


aluminium frames and penledges (coated or painted)

No 75.60
F1100089 600 x 900mm No 137.50
F1100090 900 x 1200mm No 178.80
F1100091 900 x 1500mm
No 206.30
F1100092 900 x 1800mm
No 226.90
F1100093 1200 x 1500mm
No 275.00
F1100094 1200 x 1800mm
No 364.40
F1100095 1200 x 2400mm
No 563.80
F1100096 1200 x 3600mm

Wall mounted enamelled magnetic w hite/green board


consisting of ceramicsteel writing surfaces with 0.4mm thick
aluminium backing sheet laminated to paper honeycomb core
infill glued to 12mm plywood backing complete with anodised
aluminium frames and penle

F1100097 900 x 1200mm No 103.10


No 294.70
F1100098 1200 x 2400mm
F1100099 1200 x 3050mm No 377.99

BW-F46
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 100000 NOTICE BOARDS, CHALKBOARDS (CONT'D)

Wa mounted enamelled magnetic white/green board


consisting of ceramicsteel writing surfaces with 0.4mm thick
aluminium backing sheet laminated to paper honeycomb core
infill glued to 12mm plywood backing complete with anodised
aluminium frames and penle (Cont'd)

F1100100 1200 x 3600mm No 412.00

F1100101 1200 x 4850mm No 603.20

F1100102 Other sizes not stated in items (F1100097) to (F11000101) m2 85.86

F1 100103 3600 x 1200mm with 1 m manuscript lines No 1,242.00


F1 100104 1200 x 1200mm with sliding graphboard No 745.20

F1 200000 TIMBER PELMETS

Supply new or in replacement 150 x 150mm timber pelmets to


curtain rails, sliding partitions, etc

F1200001 Kapoh m 7.05


F1200002 Teak ply m 8.55

F1 300000 CURTAINS AND BLINDS

Perforated pvc vertical blinds of approved brand fixed


complete with cleats, pulleys, cords, etc

F1300001 Not exceeding 2.00 m2 m2 33.91

F1300002 Exceeding 2.00 m2 m2 28.30


F1300003 m2 46.40
Supply and fix approved vertical blinds complete with all necessary
accessories
Supply and fix the following components (vertical blind) (Rate
shall be inclusive of taking out and disposing existing)

F1300004 Louvres m2 44.00

F1300005 Head unit control ball chain no 6.60

F1300006 Carrier no 3.10

F1300007 Louvre hanger no 0.60

BW-F47
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 300000 CURTAINS AND BLINDS (CONT'D)

Supply and fix the following components (vertical blind) (Rate


shall be inclusive of taking out and disposing existing)
(Cont'd)

F1300008 Polyester ball chain with clip m 4.40

F1300009 Polyester ball chain connector m 0.80

F1300010 Weight no 3.30

F1300011 Drawing cord m 1.10


F1300012 set 5.50
Check and service the vertical blinds (excluding change the
components) necessary accessories

Venetian blind of approved brand fixed complete with cleats,


pulleys, cords, etc

F1 300013 Not exceeding 1.00 m2 m2 36.30

F1300014 Not exceeding 2.00 m2 m2 49.20

F1300015 Exceeding 2.00 m2 m2 42.55

Venetian blind with magic baton of approved brand fixed


complete with cleats, pulleys, cords, etc

F1300016 Not exceeding 2.00 m2 m2 86.70

F1300017 Exceeding 2.00 m2 m2 71.30

Supply, sew and hang heavy duty PVC blackout curtain (any
colour) including double pleats, folding edges, hooks and all
necessary accessories

F1300018 Not exceeding 2.00 m2 m2 40.07

F1300019 Exceeding 2.00 m2 m2 33.37

Stage curtains

Motorised operated proscenium stage curtains; super quality


100% cotton velvet in 50% fullness, durable, flame resistance
stage curtain, fitted with tie tapes, hemmed and chain
weighted at base and stage track, suspension pipes and all
necessary accessories

F1300020 Stage curtains m2 169.56

F1300021 Fly border curtains m2 93.64

BW-F48
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 300000 CURTAINS AND BLINDS (CONT'D)

Stage curtains

Motorised operated proscenium stage curtains; super quality


100% cotton velvet in 50% fullness, durable, flame resistance
stage curtain, fitted with tie tapes, hemmed and chain
weighted at base and stage track, suspension pipes and all
necessary accessories (Cont'd)

F1300022 Dress leg curtains


m2 73.44
F1300023 Backdrop m2 211.36
m2 193.00
F1300024 Motorised stage fly bars including all necessary structural
members, suspension accessories etc. all in galvanised steel

F1400000 CHICKS/BLINDS

F1400001 Unpainted and unlined split chicks properly and stro ngly m2 18.70
constructed with ropes of No 8 white glazed cord or nylon cord, 25
mm diameter galvanised pulleys secured to galvanised screw
hooks, size 18 mm x 100 mm brass cleat fixed with brass screws,
additional brass cleat or cup hooks are to be provided and
securely fixed at the bottom of the chicks on the outside to prevent
the chicks being blown out. (rate includes for all cutting and
plugging to brickwork, concrete, etc required and for all making
good of plaster, woodwork and decoration as necessary)

F1400002 Add to above item (F1400001) for painting one side with one coat m2 4.35
of primer, one undercoat and one finishing coat of enamel paint

F1 300003 Add to above item (F1 300001) for lining one side with first quality m2 4.35
approved blue drill cloth or approved plastic cloth including
properly binding the edges and allowing for all cutting and waste

F1500000 CURTAIN RAILS

White plastic curtain rail complete with brackets, stops and


gliders

F1 500001 For light weight fabric curtain


m 11.85
F1500002 For heavy fabric curtain m 17.40

F1500003 For heavy fabric curtain (double tracks) m 38.50

BW-F49
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1500000 CURTAIN RAILS (CONT'D)

Approved aluminium curtain straight track complete with


transverse cords, overlap rails, brackets, pulley seats, curtain
hooks, etc

F1500004 For light weight fabric curtains m 25.55

F1500005 For heavy draperies m 33.30


F1500006 No 21.40
Extra over aluminium straight track for 400 x 400 mm single curve
rail sections
F1500007 No 29.00
Extra over aluminium straight track for 400 x 400 mm single curve
rail sections include extra hanger rod where necessary
F1500008 No 28.90
Extra over aluminium straight track for 910 x 910 mm single curve
rail sections
F1400009 No 39.10
Extra over aluminium straight track for 910 x 910 mm single curve
rail sections include extra hanger rod where necessary

F1 500010 Extra over aluminium straight track for double connector No 71.30

F1500011 Extra over aluminium straight track for double connector include No 96.80

Approved aluminium curtain straight track complete with


transverse cords, overlap rails, brackets, pulley seats, curtain
hooks, etc

Extra over aluminium straight track for suspension adjustable rod


hangers

F1 500011 Not exceeding 500 mm length No 11.90

F150001 1 Exceeding 500 mm and not exceeding 700 mm length No 12.15

F150001 1 Exceeding 700 mm and not exceeding 1100 mm length No 15.90

F150001 1 Exceeding 1100 mm and not exceeding 1600 mm length No 17.50

Approved aluminium curtain track in curved section


(continual bending rail) including bending and all necessary
wall brackets, rollers, end caps, chord, fittings etc

F1500012 For heavy draperies m 17.90

BW-F50
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1500000 CURTAIN RAILS (CONT'D)

90 degree curvature monotrack

F1500013 90 degree curvature monotrack including aluminium solid tracks, m 53.50


suspension covers, tube suspension collars and complete with
fittings

F1 600000 PROJECTION SCREENS

Manually operated wall mounted retractable projection screen


with tear proof fibreglass matt-white screen attached to rigid
steel roller encased in heavy gauge steel case with built-in
tensioning devices and including all necessary wall or ceiling
bracket and additional stainless steel cable tile as secondary
tying

F1600001 1500mm x 1500mm


No 169.29
F1600002 1800mm x 1800mm No 188.10

F1600003 2100mm x 2100mm No 320.76


F1600004 2400mm x 2400mm No 409.86

Wall mounted motorised projection screen with tear proof


fibreglass matt-white screen attached to rigid steel roller
encased in heavy gauge steel case with built-in tensioning
devices and additional stainless steel cable tile as secondary
tying

F1 600005 3000mm x 3000mm


No 1,490.40
F1600006 4880mm x 4880mm No 4,719.60

F1600007 6000mm x 6000mm No 5,961.60


Set 800.00
F1600008 Supply and install approved motorized projection screen with
motor,high and low limit switch and control switch or remote
control, size L2000mm x 2700mm

F1600009 Supply and install approved motorized projection screen, size m2 180.00
more than L2000mm with approved motor, high and low limit
switch and control switch or remote control with different type of
size includes set up staging for the work

F1600010 Supply and install additional control switch for motorized projection Set 100.00
screen with all necessary wiring, drilling of hole etc at teaching
console or wall

F1600011 Supply and replace existing screen only w/o replacement of Set 165.00
brackets including removal and disposal
BW-F51
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 700000 SYSTEM FURNITURE

System furniture consisting of partition panel finish in ap


p r o v e d f ab r i c s an d t i mb er v en e er s, h ar d w ar e s,
connections, end pieces, tables, storage units, drawers, trays,
signages, bins, metal cupboards, tasklights complete with all
other components

Modular screens covered with fabric (Class O) complete with stop


end panels and posts

F1700001 750mm x 1200mm High No 182.63

F1700002 750mm x 1650mm High No 229.82

F1700003 750mm x 1800mm high No 239.76

F1700004 900mm x 1800mm high No 277.02

Low level partitions panel with clear view glass panel

F1700005 450mm x 1200mm high No 173.88

F1700006 750mm x 1800mm high No 291.92

F1700007 900mm x 1200mm high No 229.82

F1700008 900mm x 1800mm high No 335.34

Worktops

F1700009 1500 x 750 x 750mm high worktops with metal modesty panels No 273.24
and metal support legs

F1700010 1500 x 600 x 750mm high side returns worktops No 132.95


F1700011 No 187.60
1500 x 600 x 750mm high side returns worktops with metal
support legs

F1700012 Factory baked enamel finish steel hanging open book shelf 750 x No 49.68
375mm

F1700013 Factory baked enamel finish steel hanging flipper door cabinets No 222.37
750 x 375mm

F1700014 Factory baked enamel finish steel mobile pedestal with 2-box and No 124.20
1-file floor standing pedestal complete with lateral file drawers with
locks

Factory baked enamel finish steel storage cabinets with storage


insert components and file drawers and locks

BW-F52
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 700000 SYSTEM FURNITURE (CONT'D)

System furniture consisting of partition panel finish in


a p p r o ve d fa b r i c s a n d t i m b e r ve ne e r s , h a r dw a r e s ,
connections, end pieces, tables, storage units, drawers, trays,
signages, bins, metal cupboards, tasklights complete with all
other components (Cont'd)

F1700015 915 x 457 x 1480mm High No 223.56

F1700016 915 x 457 x 1830mm High No 242.24

F1700017 250 x 350 x 55mm IN/OUT/KIV robust tinted perspex stackable No 37.26
tray with rounded edges; in set of three complete with risers and
signage for 'IN', 'OUT' AND 'KIV'

F1700018 Wall signage with a base, grooved insert, clear protective tamper No 11.40
resistant lens cover, 3 sprues of 5/16" characters, 6 sprues of 1/2"
characters. Mounting hardware and double sided taped.

F1700019 285 x 210 x 310mm high plastic waste bins of approved colour No 12.42
with rounded edges

F1700020 Twin 13A switched socket outlets, connectors and 3-pin plugs No 18.70

F1700021 Single telephone outlets No 9.94

F1700022 Single data outlets No 9.94

F1700023 Task light (1x1 8W) fitted with energy efficient compact fluorescent No 111.78
lamp with excellent colour rendering CRI of more than 85 and
400K

Office chairs consisting of approved fabric upholstery, moul


de d foa m, cas tor s, ar mres ts, pne umati c he ight
adjustment, swivel and back tilt with upright lock including all
other components and accessories

F1700024 High back chairs with armrest and wheels No


146.56
F1700025 Mid back chairs with armrest and wheels No 139.10
F1 700026 Mid back chairs with wheels No 101.30

BW-F53
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 700000 SYSTEM FURNITURE (CONT'D)

F1700027 System furniture for HOD, AM, OM (cubicle space of 8m2) set 2,400.00
consisting of partition panel (1 .80m high) finish in approved fabrics and
timber veneers, hardwares, connections, end pieces, tables,
storage units, drawers, open hanging shelves, hanging locked
cabinets, pedestal cabinets, signages, bins, metal cupboards, high
back fabric chair with armrest and wheels (1no), low back fabric
chairs with armrest and wheels (2nos), tasklights complete with all
other components panel finish in approved fabrics, connections,
end pieces, tables, storage units, drawers, trays, signages,
tasklights complete with all other components and 1 no. of staff
chair and 2 nos. of visitor chairs

F1700028 System furniture for teachers (cubicle space of 4m2) consisting ofset 1,800.00
partition panel (1.50m to 1.80m high) finish in approved fabrics
and timber veneers, hardwares, connections, end pieces, tables,
storage units, drawers, open hanging shelves, hanging locked
cabinets, pedestal cabinets, signages, bins, metal cupboards, low
back fabric chair with armrest and wheels, tasklights complete with
all other components

F1 800000 SUNDRIES

Chicken wire netting

F1800001 24 gauge galvanised iron hex chicken wire netting (13 mm each) (fillets m2 4.95
measured separately)

F1800002 Supply only 13mm x 13mm x 1.2mm thick stainless steel chicken wire m2 34.70
mesh

F1800003 Install only stainless steel chicken wire mesh m2 5.50

Fly-proof netting to windows, doors, panels, etc

F1800004 Nylon fly-proof netting m2 4.10

F1800005 Aluminium fly proof netting m2 7.50

Gal v an i sed f ab r i c an d wel d m esh i n ven t g r il l ewo r k,

undersides of eaves, etc (fixed to timber or metal frames)


(fillets measured separately)

Expanded steel ornamesh

F1800006 16 x 38 mm x 1 mm thick m2 5.05

F1800007 22 x 57 mm x 2 mm thick m2 12.80

F1800008 35 x 76 mm x 2 mm thick m2 8.90

BW-F54
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 800000 SUNDRIES (CONT'D)

Galvanised fabric and weldmesh in vent grillework,


undersides of eaves, etc (fixed to timber or metal frames)
(fillets measured separately) (Cont'd)

Expanded steel ornamesh (Cont'd)

F1800009 35 x 76 mm x 3 mm thick m2 20.30

Expanded steel balustrade mesh

F1800010 25 x 40 mm x 3 mm thick m2 18.15

F180001 1 33 x 102 mm x 3 mm thick m2 12.00

Expanded steel grid mesh

F1800012 42 x 135 mm x 5 mm thick m2 36.70

F1800013 43 x 135 mm x 5 mm thick m2 49.70

F1800014 30 x 75 mm x 3 mm thick m2 38.40

F1800015 30 x 75 mm x 5 mm thick m2 75.85

Square weldmesh

F1800016 50 x 50 mm x 4.10 mm thick m2 7.05

F1800017 50 x 50 mm x 3.25 mm thick m2 4.95

Fine mesh

F1 800018 12.5 x 12.5 mm 1.5 mm thick m2 5.85

F1800019 12.5 x 12.5 mm x 1.2 mm thick m2 4.80

F1800020 12.5 x 25 mm x 1.5 mm thick m2 4.60

F1800021 12.5 x 25 mm x 1.2 mm thick m2 3.40

F1800022 25 x 25 mm x 1.5 mm thick m2 3.40

F1800023 25 x 25 mm x 1.2 mm thick m2 2.40

F1800024 50 x 50 mm x 1.5 mm thick m2 1.80

F1800025 50 x 25 mm x 2.0 mm thick m2 4.25

F1800026 50 x 50 mm x 2.0 mm thick m2 3.05

BW-F55
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 800000 SUNDRIES (CONT'D)

Galvanised fabric and weldmesh in vent grillework,


undersides of eaves, etc (fixed to timber or metal frames)
(fillets measured separately) (Cont'd)

Roof mesh

F1800027 75 x 75 mm x 1.5 mm thick m2 1.35


F1800028 m2 2.90
Extra over above items (G1700004) to (G1700024) for tack
welding to metal frames (welding equipment measured separately)
(area of mesh measured)

Woven wire or perforated zinc cut to required sizes and fixed


complete including metal or wooden bead and 2 coats of
paint to bead

F1800029 Tinned wire gauze m2 8.80

F1800030 Aluminium, brass or copper m2 15.65

F1800031 Perforated zinc m2 4.85

Brackets for adjustable shelves including drilling holes

F1 800032 Approved nylon brackets No 0.30

F1800033 Approved steel plugs No 0.55


F1800034 No 3.02
Black Japanned brackets for shelves, 225 mm x 225 mm including
matching screws

F1800035 Black Japanned brackets for shelves, 300 mm x 300 mm including No 6.30
matching screws

F1 900000 SUNDRY FIXINGS, BOLTS

Mild steel hex bolts with nuts and washers including drilling
holes in metal or wood, if necessary
F1900001 No 0.30
5 mm diameter, exceeding 16 mm and not exceeding 50mm shank
length

F1900002 5 mm diameter, 16 mm - 40mm shank length No 0.30

F1900003 5 mm diameter, 45 mm shank length No 0.40

F1900004 5 mm diameter, 50 mm shank length No 0.50

BW-F56
F : CARPENTRY & JOINERY
No 0.30
F1900005
6 mm diameter, exceeding 20 mm and not exceeding 50mm shank
length

BW-F57
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 900000 SUNDRY FIXINGS, BOLTS (CONT'D)

Mild steel hex bolts with nuts and washers including drilling
holes in metal or wood, if necessary (Cont'd)

F1900006 6 mm diameter, 20 mm - 40mm shank length No 0.30

F1900007 5 mm diameter, 45 mm shank length No 0.40

F1900008 5 mm diameter, 50 mm shank length No 0.50


F1900009 No 0.50
10 mm diameter, exceeding 20 mm and not exceeding 50mm
shank length

F1900010 10 mm diameter, 20 mm - 25 mm shank length No 0.50

F190001 1 10 mm diameter, 30 mm - 50 mm shank length No 0.60


F1900012 No 0.70
13 mm diameter, exceeding 50 mm and not exceeding 75mm
shank length

F1 900013 13 mm diameter, 50 mm - 60 mm shank length No 1.20

F1900014 13 mm diameter, 63 mm - 75 mm shank length No 1.40

F1900015 13 mm diameter, 90 mm shank length No 1.70

F1900016 13 mm diameter, 100 mm shank length No 1.80

F1900017 13 mm diameter, 115 mm shank length No 2.10

F1900018 13 mm diameter, 125 mm shank length No 2.30


F1900019 No 1.30
13 mm diameter, exceeding 75 mm and not exceeding 125mm
shank length
F1900020 No 2.95
13 mm diameter, exceeding 125 mm and not exceeding 250 mm
shank length
F1900021 No 0.81
16 mm diameter, exceeding 50 mm and not exceeding 75mm
shank length

F1 900022 16 mm diameter, 50 mm - 63 mm shank length No 1.40

F1900023 16 mm diameter, 75 mm shank length No 1.70

F1900024 16 mm diameter, 90 mm shank length No 1.80

F1900025 16 mm diameter, 100 mm shank length No 2.10

F1900026 16 mm diameter, 115 mm - 125 mm shank length No 2.30

BW-F58
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 900000 SUNDRY FIXINGS, BOLTS (CONT'D)

Mild steel hex bolts with nuts and washers including drilling
holes in metal or wood, if necessary (Cont'd)
F1900027 No 5.10
16 mm diameter, exceeding 125mm & not exceeding 250mm
shank length
F1900028 No 1.30
16 mm diameter, exceeding 75 mm and not exceeding 125mm
shank length
F1900029 No 0.81
19 mm diameter, exceeding 50 mm and not exceeding 75mm
shank length

F1 900030 19 mm diameter, 60 mm - 75 mm shank length No 1.70

F1900031 19 mm diameter, 90 mm shank length No 1.80

F1900032 19 mm diameter, 100 mm shank length No 2.10

F1900033 19 mm diameter, 115 mm shank length No 2.30

F1900034 19 mm diameter, 125 mm shank length No 2.70


F1900035 No 1.40
19 mm diameter, exceeding 75 mm and not exceeding 125mm
shank length
F1900036 No 4.85
19 mm diameter, exceeding 125 mm and not exceeding 250 mm
shank length

F1900037 No 0.25
Add to above items (F1900001) to (F1900036) if including taking
out and making good work disturbed

Hot dipped galvanised bolts with nuts and washers or other


equal and approved type including drilling holes in metal or
wood, if necessary
F1900038 No 1.70
16 mm diameter, exceeding 45 mm and not exceeding 75mm
shank length

F1900039 16 mm diameter, 45 mm shank length No 3.20

F1900040 16 mm diameter, 50 mm - 63 mm shank length No 3.40


F1900041 No 2.80
19 mm diameter, exceeding 50 mm and not exceeding 75 mm
shank length

F1900042 19 mm diameter, 50 mm shank length No 4.40

F1900043 19 mm diameter, 58 mm shank length No 4.50

BW-F59
F : CARPENTRY & JOINERY
F1900044 19 mm diameter, 63 mm shank length No 4.80

BW-F60
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 900000 SUNDRY FIXINGS, BOLTS (CONT'D)

Hot dipped galvanised bolts with nuts and washers or other


equal and approved type including drilling holes in metal or
wood, if necessary (Cont'd)

F1900045 19 mm diameter, 75 mm shank length No 5.10


No 3.70
F1900046 22 mm diameter, exceeding 50 mm and not exceeding 75 mm
shank length
No 6.20
F1900047 22 mm diameter, 50 mm - 58 mm shank length
No 6.30
F1900048 22 mm diameter, 63 mm shank length
No 6.90
F1900049 22 mm diameter, 75 mm shank length
No 0.78

F1900050 25 mm diameter, exceeding 50 mm and not exceeding 75 mm


shank length No 8.70

F1900051 25 mm diameter, 75 mm shank length

Rawl bolt loose type or other equal and approved retraction


bolt with nut and washer including drilling holes in concrete,
brickwork, metal or wood as required
No 2.55
F1900052 5 mm diameter, 50 mm bolt length and 36 mm shield length with
nut
No 2.75
F1900053 6 mm diameter, 65 mm bolt length and 46 mm shield length with
nut
No 2.70
F1900054 6 mm diameter, 75 mm bolt length and 46 mm shield length with
nut
No 2.80
F1900055 6 mm diameter, 120 mm bolt length and 46 mm shield length with
nut
No 4.10
F1900056 6 mm diameter, 115 mm bolt length and 46 mm shield length with
nut
No 2.90
F1900057 8 mm diameter, 75 mm bolt length and 52 mm shield length with
nut
No 3.75
F1900058 8 mm diameter, 100 mm bolt length and 52 mm shield length with
nut
No 3.10
F1900059 10 mm diameter, 85 mm bolt length and 62 mm shield length with
nut
No 3.70
F1900060 10 mm diameter, 110 mm bolt length and 62 mm shield length with
nut

BW-F61
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 900000 SUNDRY FIXINGS, BOLTS (CONT'D)

Rawl bolt loose type or other equal and approved


retraction bolt with nut and washer including drilling holes
in concrete, brickwork, metal or wood as required (Cont'd)

F1900061 10 mm diameter, 130 mm bolt length and 62 mm shield length No 3.95


with nut

F1900062 10 mm diameter, 110 mm bolt length and 78 mm shield length No 3.95


with nut

F1900063 10 mm diameter, 130 mm bolt length and 78 mm shield length No 4.00


with nut

F1900064 12 mm diameter, 95 mm bolt length and 72 mm shield length No 4.70


with nut

F1900065 12 mm diameter, 120 mm bolt length and 72 mm shield length No 5.10


with nut

F1900066 12 mm diameter, 120 mm bolt length and 96 mm shield length No 5.90


with nut

F1900067 12 mm diameter, 185 mm bolt length and 96 mm shield length No 6.40


with nut

F1900068 16 mm diameter, 130 mm bolt length and 110 mm shield No 7.95


length with nut

F1900069 16 mm diameter, 140 mm bolt length and 110 mm shield No 8.05


length with nut

F1900070 16 mm diameter, 160 mm bolt length and 110 mm shield No 8.40


length with nut

F1900071 16 mm diameter, 210 mm bolt length and 110 mm shield No 9.85


length with nut

F1900072 16 mm diameter, 210 mm bolt length and 158 mm shield No 10.70


length with nut

F1900073 20 mm diameter, 165 mm bolt length and 130 mm shield No 10.70


length with nut

F1900074 20 mm diameter, 185 mm bolt length and 130 mm shield No 10.70


length with nut

F1900075 25 mm diameter, 260 mm bolt length and 180 mm shield No 19.45


length with nut

F1900076 25 mm diameter, 310 mm bolt length and 180 mm shield No 21.45


length with nut

BW-F62
F : CARPENTRY & JOINERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1 900000 SUNDRY FIXINGS, BOLTS (CONT'D)

Approved drive pins fixed to timber, sheet metal etc to


structural steel

F1900077 3.7 mm shank diameter, 10 mm to 27 mm shank length No 0.45

F1900078 3.7 mm shank diameter, 32 mm to 47 mm shank length No 0.45

F1900079 3.7 mm shank diameter, 52 mm to 72 mm shank length No 0.60

F1 900080 3.7 mm shank diameter, 82 mm to 117 mm shank length No 0.80

BW-F63
SECTION G: IRONMONGERY
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G100000 DEMOLITION / ALTERATIONS

Taking out existing door ironmongery; cart away and make


good work disturbed

G100001 Hinges (any kind and size)


No 0.60
No 2.16
G100002 Locks and latches (any kind and size) including furniture (i.e. lever
handles, rebated kits and escutcheon)

G100003 Lock (any type and size) including furniture, cart away and make No 3.80
good work disturbed

G100004 Latch (any type and size) including furniture, cart away and make No 2.30
good work disturbed

G100005 Door closers with or without backcheck and parallel arm brackets No 3.13

G100006 Door stops No 0.50

G100007 Coat hooks No 0.50

G100008 Cabin hook and eye or hasp and staples No 0.50


No 0.70
G100009 Hook (any type) eye or hasp and staple, remove off site and make
good work disturbed

G100010 Floor springs No 28.10

Set 60.50
G100011 Take out existing floor spring and remove off site including taking
down door leaf and making good work disturbed

G100012 Floor springs including repairing and replacing any defective Set 110.60
components including taking down and rehanging door leaf where
necessary

G100013 Take out existing floor spring, repair/service without replacing any Set 121.00
components, fix back floor spring including taking down and
rehanging door leaf and making good work disturbed

G100014 Sliding door assembly complete with tracks, channel brackets, Set 24.30
hangers, guides and accessories

G100015 Adjusting, easing, oiling and making good sliding door gear m2 27.22
assembly (any type) and including replacing any missing or
damaged rollers, guides, brackets and accessories; taking out and
rehanging door as necessary

G100016 Adjusting, easing, oiling and making good sliding and folding door gear m2 31.10
assembly (any type) and including replacing any missing or
damaged rollers, guides, brackets and accessories; taking out and
rehanging door as necessary

BW-G1
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G100000 DEMOLITION / ALTERATIONS (CONT'D)

Taking out existing door ironmongery; cart away and make


good work disturbed (Cont'd)

G100017 Casement friction stays No 0.60

G100018 Casement fasteners No 0.60

Taking out existing fitment ironmongery; cart away and make


good work disturbed

G100019 Hinges No 0.50

G100020 Cupboard and drawer locks No 1.10

G100021 Fitments knobs, handles and pulls No 0.50


G100022 Fitments magnetic catches No 0.50

G200000 DOOR IRONMONGERY

Hinges to timber or steel doors in timber or steel frames with


matching screws

G200001 100mm high brass butt hinges No 5.29

G200002 127mm high brass butt hinges No 5.72

G200003 100mm high stainless steel butt hinges No 5.72

G200004 100mm high ball bearing stainless steel butt hinges No 6.26

G200005 127mm high stainless steel butt hinges No 7.02

G200006 125mm high stainless steel butt hinges No 15.29

G200007 127mm high ball bearing stainless steel butt hinges No 7.70

G200008 100mm high brass parliament hinges No 8.75

Mortise locks and latches with strike plates

G200009 Stainless steel 7 pin single cylinder No 53.10

G200010 Stainless steel 7 pin double cylinder No 56.30

G20001 1 Stainless steel 7 pin single thumbturn cylinder No 52.91


G200012 No 55.70
Stainless steel 7 pin single thumbturn cylinder with master key and
key alike system

BW-G2
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Mortise locks and latches with strike plates (Cont'd)


G200013 No 57.78
Stainless steel 7 pin double thumbturn cylinder with master key
and key alike system

G200014 Stainless steel standard pattern cylinder rim night latches No 23.78

G200015 Stainless steel single cylinder rim night latches No 32.62

G200016 Stainless steel double cylinder rim night latches No 33.70

G200017 Stainless steel single cylinder mortise latches No 32.62

G200018 Stainless steel double cylinder mortise latches No 33.70

G200019 Stainless steel rebated single cylinder mortise latches No 34.78

G200020 Stainless steel rebated double cylinder mortise latches No 35.86

G200021 Stainless steel single cylinder mortise entrance locks No 33.26

G200022 Stainless steel double cylinder mortise entrance locks No 34.34

G200023 Stainless steel single cylinder mortise deadlocks No 42.55

G200024 Stainless steel double cylinder mortise deadlocks No 43.63

G200025 Stainless steel single cylinder mortise nightlatch locks No 42.55

G200026 Stainless steel double cylinder mortise nightlatch locks No 43.63

Handles

G200027 150mm aluminum pull handles No 6.90

G200028 250mm aluminum pull handles No 21.92

G200029 Stainless steel fixed knob handle on rose No 24.84

G200030 Stainless steel lever handle on rose No 37.26

G200031 Stainless steel cup handles No 7.45

G200032 200mm stainless steel pull handles No 17.49

G200033 600mm stainless steel pull handles No 88.00

BW-G3
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Escutcheon

G200034 Stainless steel cylinder escutcheon No 4.85

G200035 Stainless steel blank escutcheon No 4.86

Matching rebated kits for locksets

G200036 Matching rebated kits No 8.75

Jimmy proof locksets with strike plates complete with


restricted rim cylinder and master keys systems

G200037 Jimmy proof locksets No 131.22

Sliding door locks

G200038 Single cylinder mortise sliding door locks No 39.69

G200039 Double cylinder mortise sliding door locks No 48.80

G200040 Rebated single cylinder mortise sliding door locks No 74.73

G200041 Rebated double cylinder mortise sliding door locks No 76.89

Roller shutter locks

G200042 Roller shutter mortise locks No 27.30

Brass padlocks

G200043 40mm wide padlocks No 9.00

G200044 50mm wide padlocks No 13.60

G200045 60mm wide padlocks No 18.70

Door closers with matching screws

G200046 Door closers No 60.80

G200047 Door closers with back check No 62.96

G200048 Door closers with back check and delay action No 86.72

G200049 Parallel arm brackets No 7.56

Door selectors with matching screws

G200050 Stainless steel door selectors No 33.20

BW-G4
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Emergency exit hardware including latch devices, cylinder


panic locks and split spindle

G200051 For single leaf doors No 122.10

G200052 For double leaves doors No 175.50

Floor springs (150 kg) with accessories and covers (per leaf
per door)

G200053 Single action floor springs Set 332.60


G200054 Set 361.90
Supply only 'Union' duo-check single action heavy duty floor
springs (per set of two)

G200055 Double action floor springs Set 336.70

Top and bottom patch fittings and patch locks complete with
accessories and covers (per leaf per door)

G200056 Patch fittings and patch locks Set 328.30

G200057 Supply only Dorma PT10 insert for patch fitting glass door No 66.00
G200058 No 132.00
Supply only Dorma PT10 lower patch c/w insert, base and cover
for patch fitting glass door

G200059 Supply only Dorma PT20 insert for patch fitting glass door No 66.00
G200060 No 132.00
Supply only Dorma PT20 upper patch c/w insert, base and cover
for patch fitting glass door

G200061 Supply only Dorma PT24 top pivot for patch fitting glass door No 66.00
G200062 No 99.00
Supply only Dorma PC91 cylinder - Nikel for patch fitting glass
door

G200063 Supply only Dorma AL door strap - 7422 for glass door No 66.00

G200064 Supply only Dorma AL top centre for glass door No 66.00

G200065 Supply only Dorma AL receiver for glass door No 66.00

G200066 Supply only Dorma GD door strap - 8023 for top and bottom APG No 66.00
Shoe for glass door
G200067 No 66.00
Supply only Dorma GD top centre for top and bottom APG Shoe
for glass door

BW-G5
G : IRONMONGERY
No 66.00
G200068
Supply only Dorma GD receiver for top and bottom APG Shoe for
glass door

BW-G6
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Top and bottom patch fittings and patch locks complete with
accessories and covers (per leaf per door) (Cont'd)

G200069 Supply only Dorma door strap - 7421 for top and bottom APG No 66.00
Shoe for glass door

Door stops with matching screws

G200070 38mm diameter rubber door stops No 1.93

G200071 Stainless steel floor mounted door stops No 11.27

G200072 Stainless steel wall mounted door stops No 11.27

G200073 Stainless steel spherical magnetic door holders No 6.47

Buffer coat hooks with matching screws

G200074 Aluminium coat hooks with black inserts No 3.45

G200075 Stainless steel buffer coat hooks No 5.25

Dust proof sockets

G200076 Stainless steel dust proof sockets No 10.90

Ball catches

G200077 Stainless steel ball catches No 8.53

Door bolts with matching screws

G200078 150mm diameter brass barrel bolts No 3.92

G200079 250mm diameter brass barrel bolts No 5.36

G200080 150mm diameter stainless steel flush bolts No 9.43

G200081 200mm diameter stainless steel flush bolts No 12.05

G200082 300mm diameter stainless steel flush bolts No 13.35

G200083 Stainless steel toilet indicating bolts No 29.05

G200084 Supply and fix Showa 11 00P stainless steel indicating bolts no 24.30

G200085 Supply and fix M & B stainless steel indicating bolt for toilet cubilce no 37.40

BW-G7
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Cabin hooks and eyes with matching screws

G200086 75mm high brass hooks and eyes

G200087 150mm high brass hooks and eyes


No 5.17
G200088 200mm high brass hooks and eyes No 6.10

G200089 250mm high brass hooks and eyes No 9.10


G200090 3000mm high brass hooks and eyes
No 13.10
G200091 75mm high stainless steel hooks and
No 17.30
eyes
No 2.59
G200092 150mm high stainless steel hooks and eyes
No 4.64
G200093 200mm high stainless steel hooks and eyes
No 7.67
Hasps and staples with matching screws

G200094 75mm brass hasps and staples

G200095 100mm brass hasps and staples No 11.16


No 13.75
G200096 125mm brass hasps and staples
No 18.45
G200097 75mm steel hasps and staples

G200098 100mm steel hasps and staples No 7.24

G200099 125mm steel hasps and staples No 8.64


No 12.74
Sliding door gear assembly

G200100 Sliding door gear assembly complete with tracks, channel


brackets, hangers, guides and accessories (any width and
height of door) (length of opening measured) m 218.80
G200101 Sliding and folding door gear assembly complete with tracks
channel brackets, hangers, guides and accessories (any width and
height of door) (length of opening measured)
m 358.30
G200102 Supply only spring loaded sliding glass door lock including tw
keys

no. 5.50
G2001 02 Supply only sliding glass door lock (YKK YB 3K-631 1 B)
G200102 Supply only sliding glass door lock (Reliance J-6)
no. 33.00

no. 28.60

BW-G8
G : IRONMONGERY
ITEM NO. DESCRIPTION UNIT RATE
(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Door and window seals to bottom, head, jamb and meeting


stiles of doors and windows

G2001 02 Acoustic door seals m 11.34

Push plates and kicking plates

G200103 75 x 300 x 1.5mm thick - aluminium push plate No 7.40

G200104 100 x 300 x 1.2mm thick No 10.58

G200105 100 x 300 x 1.5mm thick - aluminium push plate No 9.20

G200106 110 x 50 x 1.2mm thick No 15.12

G200107 200 x 200 x 1.5mm thick - aluminium push plate No 9.50

G200108 200 x 300 x 1.2mm thick No 18.52

G200109 200 x 300 x 1.5mm thick - aluminium push plate No 20.40

G200110 200 x 900 x 1.2mm thick No 35.53

G2001 11 200 x 900 x 1.5mm thick - aluminium push plate No 49.50

G2001 12 200 x 300 x 1.5mm thick - aluminium kick plate No 20.40

G2001 13 200 x 900 x 1.5mm thick - aluminium kick plate No 49.50

Keys
G200114 No 2.40
Making and supplying keys for rim locks, mortise locks, night
latches, drawer locks, padlocks, etc

G2001 15 Duplicating keys for locksets No 3.30

G2001 16 Duplicating keys for 'KABA' lockset No 33.00

G2001 17 Duplicating keys for 'EWA DPI' security lockset 8181X series No 19.80
G200118 No 9.84
Labour and material for incorporation of master key system to
locks

G200119 Labour and material for incorporation of key alike system to locks No 9.03

BW-G9
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Fix only ironmongery to timber or steel doors in timber or


steel frames with matching screws

G200120 Hinges (any kind and size) No 1.20


G200121 No 9.83
Locks and latches (any kind and size) including furniture (i.e. lever
handles, rebated kits and escutcheon)
G200122 No 9.20
Rim lock or latch,deadlock or night latch etc c/w handle or knob, if
any (lock or latch provided)
G200123 No 10.60
Rebate type rim lock or latch,deadlock or night latch etc c/w handle
or knob, if any (lock or latch provided)
G200124 No 11.20
Mortice lock or latch c/w handle or knob, if any (lock or latch
provided)
G200125 No 12.50
Rebate type mortice lock or latch c/w handle or knob, if any (lock
or latch provided)
G200126 No 37.80
Jimmy proof locksets with strike plates complete with restricted
rim cylinder

G200127 Sliding door locks (any kind and size) No 3.78

G200128 Roller shutter locks No 6.70

G200129 Pull handles No 2.70


G200130 No 9.83
Single or dual control door closers with or without backcheck and
parallel arm brackets

G200131 Door closer or bracket to door and frame (door closer provided) No 7.70
G200132 No 12.10
Concealed type door closer or bracket to door and frame (door
closer provided)

G200133 Emergency exit device hardware for single doors No 22.68

G200134 Emergency exit device hardware for double leaves doors No 30.24

G200135 Single or double action floor springs No 9.83


G200136 No 71.50
Floor spring including preparing floor to receive floor spring,
making good work disturbed and rehanging door leaf (floor spring
provided separately)

G200137 Patch fittings and patch locks for single doors No 19.44

BW-G10
G : IRONMONGERY
G200138 Patch fittings and patch locks for double leaves doors No 27.00

BW-G11
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G200000 DOOR IRONMONGERY (CONT'D)

Fix only ironmongery to timber or steel doors in timber or


steel frames with matching screws

G200139 Door stops No 2.27

G200140 Dust proof sockets No 4.32

G200141 Ball catches No 2.70

G200142 Door bolts (any kind and size) No 3.78

G200143 Indicating bolt (bolt provided) No 5.30

G200144 Barrel or flush bolt (bolt provided) No 2.60

G200145 Hooks and eyes No 2.48


G200146 Hasps and staples No 2.81

G300000 WINDOW IRONMONGERY

Casement friction stays to timber or steel windows in timber


or steel frames with matching screws

G300001 250mm galvanised steel No 5.90

G300002 300mm galvanised steel No 7.55

G300003 200mm brass No 8.80

G300004 250mm brass No 10.90

G300005 300mm brass No 11.35

Casement fasteners to timber or steel windows in timber or


steel frames with matching screws

G300006 Galvanised steel fasteners with hook plates or mortise plates No 4.85
Combination of casement hinges and stays to timber or steel
windows in timber or steel frames with matching screws

G300007 300mm galvanised steel Set 12.50

G300008 500mm galvanised steel Set 21.70

BW-G12
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G300000 WINDOW IRONMONGERY (CONT'D)

Fix only window ironmongery to timber or steel doors in


timber or steel frames with matching screws

G300009 Casement friction stays No 2.00


G300010 Casement fasteners No 2.30

G400000 FITMENT IRONMONGERY

Hinges to fitments with matching screws

G400001 Chromium plated hinges No 7.67

G400002 Brass hinges No 6.90

G400003 Supply & fix 38mm diameter brass ring fitments hinges Pair 8.70

G400004 Nylon arch hinges No 5.90

G400005 Supply & fix 44mm long nylon arch fitments hinges Pair 8.00

G400006 Supply & fix 44mm long brass arch fitments hinges Pair 9.50

G400007 Brass hinges No 3.89

G400008 Supply & fix 50mm solid drawn brass with steel pins hinges Pair 5.50

G400009 Supply & fix 65mm solid drawn brass with steel pins hinges Pair 6.40

G400010 Supply & fix 75mm solid drawn brass with steel pins hinges Pair 7.30

G40001 1 Supply & fix 90mm solid drawn brass with steel pins hinges Pair 7.30

G400012 Supply & fix 100mm solid drawn brass with steel pins hinges Pair 8.70

G400013 Supply & fix 125mm solid drawn brass with steel pins hinges Pair 22.00

G400014 Supply & fix 150mm solid drawn brass with steel pins hinges Pair 36.30

G40001 5 Stainless steel concealed hinges with 180 degree swing No 11.34
G400016 No 14.58
Nickel plated concealed self closing type with 180 degree swing
spring loaded hinged arm

BW-G13
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G400000 FITMENT IRONMONGERY (CONT'D)

Cupboard / drawer locks

G400017 Drawer locks No 6.48

G400018 Supply only drawer lock (Union 4046) including two keys) No 14.55
G400019 No 19.10
Supply only cupboard/drawer lock (Union 4137) including two
keys)

G400020 No 11.00
Supply only cupboard/drawer lock (Viro No 69032 or 69033) or
equivalent including two keys

G400021 Cupboard locks No 6.48


G400022 No 15.20
Supply only cupboard lock (Union 4138 or 4148) including two
keys)

G400023 Supply only cupboard lock (Union 4146) including two keys) No 14.55

G400024 Supply only cupboard lock (Union 4147) including two keys) No 22.70

G400025 Supply only cupboard lock (Viro 1055) including two keys) No 8.30

G400026 Sliding cupboard locks No 27.70

G400027 Supply & install cupboard/drawer lock (Globe or Diamond) No 2.60

G400028 Supply & install cupboard lock (Ocean Camlock) No 4.10

Cupboard or drawer knobs with matching escutcheon and


screws
G400029 No 4.10
25mm diameter chromium plated , brass or bronze drawers or
cupboards dead knobs
G400030 No 5.10
38mm diameter chromium plated , brass or bronze drawers or
cupboards dead knobs
G400031 No 6.10
50mm diameter chromium plated , brass or bronze drawers or
cupboards dead knobs

G400032 40mm diameter plastic cupboard or drawer knobs No 4.02


Cupboard or drawer handles and pulls with matching screws
G400034
100 mm
long
G400033 100 mm long nylon bow handles without plate or 'U' shaped door aluminium
handles bow
handles
BW-G14
G : IRONMONGERY
without plate or 'U' shaped door handles No 1.65

No 2.15

BW-G15
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G400000 FITMENT IRONMONGERY (CONT'D)

Cupboard or drawer handles and pulls with matching screws


(Cont'd)
G400035 No 6.90
150 mm long aluminium bow handles without plate or 'U' shaped
door handles
G400036 No 8.20
200 mm long aluminium bow handles without plate or 'U' shaped
door handles
G400037 No 10.15
100 mm long brass bow handles without plate or 'U' shaped door
handles
G400038 No 10.90
150 mm long brass bow handles without plate or 'U' shaped door
handles
G400039 No 21.30
200 mm long brass bow handles without plate or 'U' shaped door
handles
G400040 No 5.40
100 mm long chromium bow handles without plate or 'U' shaped
door handles
G400041 No 6.30
150 mm long chromium bow handles without plate or 'U' shaped
door handles

G400042 No 6.70
200 mm long aluminium bow handles without plate or 'U' shaped
door handles

G400043 100mm Aluminium flush pulls No 3.90

G400044 100mm Brass flush pulls No 3.80

G400045 100mm Plastic flush pulls No 4.10

G400046 100mm Stainless steel flush pulls No 4.43

G400047 100mm aluminium angle handles to drawers No 5.08

G400048 100mm aluminium drawer pulls No 2.75

G400049 100mm brass drawer pulls No 3.45

G400050 100mm chromium plated drawer pulls No 4.60

G400051 100mm stainless steel drawer pulls No 5.18

G400052 U' shaped plastic drawer handles No 5.08

Cupboard magnetic catch with matching screws

G400053 Plastic pressure catches No 4.80

G400054 Steel magnetic pressure catches No 3.80

BW-G16
G : IRONMONGERY

ITEM NO. DESCRIPTION UNIT RATE


(S$)

G400000 FITMENT IRONMONGERY (CONT'D)

Fix only fitment ironmongery with matching screws

G400055 Hinges (any kind and size) No 1.62

G400056 Cupboard and drawer locks No 4.80

G400057 Fitments knobs, handles and pulls No 1.62

G400058 Fitments magnetic catches No 1.62

BW-G17
SECTION H: STRUCTURAL STEELWORK
H : STRUCTURAL STEELWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

H 100000 DEMOLITION / ALTERATIONS

H100001 Cutting off existing projecting metal hollow section, T-bearers, I-


beams, etc. not exceeding 100mm girth (cutting machine No 5.90
measured separately) (Rate measured per spot)

H100002 Add to item (H100001) above for each 25mm increase in girth
No 0.50
H100003 Cutting off existing projecting reinforcing bar (any size) and No 1.50
remove debris off site (hacking up concrete and cutting machine
measured separately)

H100004 Building end of steel joists, bearers, etc. into concrete work,
brickwork, etc. and making good surround with and including No 7.20
materials to match (making holes measured separately)

H200000 STRUCTURAL STEELS, BS 4360, GRADE 43A

H200001 Rolled steel of any sections or sizes including cutting, welding


including painting one coat of inhibitive primer before delivery in kg 2.64
stanchions, beams, girders, roof trusses, purlins, cleats, brackets,
etc.

H200002 Mild steel tubular or rectangular or square or circular hollow


sections of any sections or sizes including cutting, welding kg 3.20
including painting one coat of inhibitive primer before delivery, in
stanchions, beams, girders, roof trusses, purlins, cleats, brackets,
etc.

H200003 Mild steel rods, plates, angles, channels, flats, etc. cut in lengths
including all labour, bending, welding, drilling including painting kg 2.88
one coat of inhibitive primer before delivery

H300000 BOLTS

Black steel bolts (grade 8.8)

H300001 12mm diameter bolts not exceeding 75mm long


No 1.30
H300002 12mm diameter bolts exceeding 75mm and not exceeding 150mm No 1.94
long

H300003 16mm diameter bolts not exceeding 75mm long


No 1.62
H300004 16mm diameter bolts exceeding 75mm and not exceeding 150mm No 2.48
long

H300005 20mm diameter bolts not exceeding 75mm long


No 1.94

BW-H1
H : STRUCTURAL STEELWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

H300000 BOLTS (CONT'D)

Black steel bolts (grade 8.8) (Cont'd)


H300006 No 3.02
20mm diameter bolts exceeding 75mm and not exceeding 150mm
long

H300007 24mm diameter bolts not exceeding 75mm long No 3.02


H300008 No 4.21
24mm diameter bolts exceeding 75mm and not exceeding 150mm
long

Galvanised black steel bolts (grade 8.8)

H300009 12mm diameter bolts not exceeding 75mm long No 1.94


H300010 No 2.81
12mm diameter bolts exceeding 75mm and not exceeding 150mm
long

H300011 16mm diameter bolts not exceeding 75mm long No 2.81


H300012 No 3.89
16mm diameter bolts exceeding 75mm and not exceeding 150mm
long

H300013 20mm diameter bolts not exceeding 75mm long No 3.67


H300014 No 5.72
20mm diameter bolts exceeding 75mm and not exceeding 150mm
long

H300015 24mm diameter bolts not exceeding 75mm long No 5.83


H300016 No 8.32
24mm diameter bolts exceeding 75mm and not exceeding 150mm
long

High strength friction grip bolts

H300017 16mm diameter bolts not exceeding 75mm long No 2.16


H300018 No 3.46
16mm diameter bolts exceeding 75mm and not exceeding 150mm
long

H300019 20mm diameter bolts not exceeding 75mm long No 2.05


H300020 No 3.46
20mm diameter bolts exceeding 75mm and not exceeding 150mm
long

H300021 24mm diameter bolts not exceeding 75mm long No 3.24

BW-H2
H : STRUCTURAL STEELWORK
No 4.64
H300022
24mm diameter bolts exceeding 75mm and not exceeding 150mm
long

BW-H3
H : STRUCTURAL STEELWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

H300000 BOLTS (CONT'D)

Steel holding down bolt, grade 8.8 including setting in


concrete

H300023 16mm diameter bolts x 300mm long No 13.72

H300024 16mm diameter bolts x 400mm long No 14.90

H300025 16mm diameter bolts x 500mm long No 15.98

H300026 20mm diameter bolts x 300mm long No 18.47

H300027 20mm diameter bolts x 400mm long No 20.09

H300028 20mm diameter bolts x 500mm long No 21.49

H300029 24mm diameter bolts x 300mm long No 22.14

H300030 24mm diameter bolts x 400mm long No 24.52

H300031 24mm diameter bolts x 500mm long No 26.57


Holding down bolts U shaped, including setting in concrete

H300032 16mm diameter bolts x 500mm girth No 28.90

H300033 16mm diameter bolts x 700mm girth No 31.97

H300034 16mm diameter bolts x 900mm girth No 35.10

H300035 20mm diameter bolts x 500mm girth No 35.70

H300036 20mm diameter bolts x 700mm girth No 39.96

H300037 20mm diameter bolts x 900mm girth No 40.82

H300038 24mm diameter bolts x 500mm girth No 41.90

H300039 24mm diameter bolts x 700mm girth No 46.60


H300040 24mm diameter bolts x 900mm girth No 51.19

H400000 SUNDRIES

Site weld and cutting


H400001 m 1.71
Site fillet weld joints, any thickness of steel or width (weldin g
machine measured separately) (length of girth of joint measured)

BW-H4
H : STRUCTURAL STEELWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

H400000 SUNDRIES (CONT'D)

Site weld and cutting (Cont'd)

H400002 Continuous fillet weld for welding loose, corroded or new METAL m 17.70
WORK including the provision of welding rods, plant etc filing
smooth, repainting to match existing and the cutting and
removal of corroded parts, if any. (New metal work measured
separately)

H400003 Continuous fillet weld for welding loose, corroded or new m 32.90
STAINLESS STEEL members including the provision of welding
rods, plant etc filing smooth, repainting to match existing and the
cutting and removal of corroded parts, if any. (New metal work
measured separately)

H400004 Spot weld ends of wire to frames (welding machine measured No. 0.26
separately)

H400005 Spot weld for welding loose, corroded or new METAL W ORK No. 0.62
including the provision of welding rods, plant etc filing smooth,
repainting to match existing and the cutting and removal of
corroded parts, if any. (New metal work measured separately).

H400006 Spot weld for welding loose, corroded or new STAINLESS STEEL No. 3.50
members including the provision of welding rods, plant etc filing
smooth, repainting to match existing and the cutting and removal
of corroded parts, if any. (New metal work measured separately)

Grouting up gap between structural steel members and


brickwork with dry -pack cement mortar (1:1) to the
satisfaction of SO and leave clean on completion

H400007 Not exceeding 300mm wide x 50mm thick m


4.25
H400008 Exceeding 300mm wide x 50mm thick m 9.01

Wedges and grouting


Steel wedges and grouting up under steel base and bearing
plates with dry-pack cement mortar well rammed in :

H400009 25mm thick m2


32.82
H400010 50mm thick m2 33.26

BW-H5
H : STRUCTURAL STEELWORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

H500000 SURFACE TREATMENTS

H500001 Hot dipped galvanising complying with SS 117 to steel members Kg 0.97

H500002 Acid cleaning to steel members Kg 0.38

BW-H6
SECTION I: METAL WORK
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I100000 FLOOR MATS

I100001 Floor mats of floor grid assembly system comprising b ronze m2 683.10
anodised extruded aluminium rails with carpet tread finish locked
together with continuous vinyl hinges and exposed edges with
vinyl frame edging to floors irrespective of size

I200000 WINDOWS

Aluminium framed fixed windows complete with


ironmongery, fixing straps, vinyl weather strips including
building-in and pointing frames (glass measured separately)

I200001 Natural anodised finish m2 76.03

I200002 Bronze anodised finish m2 101.09

I200003 Black anodised finish m2 110.05

I200004 Polyester powder coated finish m2 93.31

I200005 Fluorocarbon coated finish m2 112.86


Aluminium framed sliding windows in single lights complete
with ironmongery, fixing straps, vinyl weather strips including
building-in and pointing frames (glass measured separately)

I200006 Natural anodised finish m2 114.59

I200007 Bronze anodised finish m2 131.76

I200008 Black anodised finish m2 138.67

I200009 Polyester powder coated finish m2 152.60

I200010 Fluorocarbon coated finish m2 172.58

Aluminium framed top / side hung casement windows in


single lights complete with ironmongery, fixing straps, vinyl
weather strips including building-in and pointing frames
(glass measured separately)

I200011 Natural anodised finish m2 163.30

I200012 Bronze anodised finish m2 186.19

I200013 Black anodised finish m2 200.56

I200014 Polyester powder coated finish m2 187.81

BW-I1
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I200000 WINDOWS (CONT'D)

Aluminium framed top / side hung casement windows in


single lights complete with ironmongery, fixing straps, vinyl
weather strips including building-in and pointing frames
(glass measured separately)

I200015 Fluorocarbon coated finish m2 207.79

Aluminium framed fixed glass louvres windows complete with


polyproylene glass holders with UV stabiliser, fixing straps,
vinyl weather strips including building-in and pointing frames
(glass measured separately)

I200016 Natural anodised finish m2 123.88

I200017 Bronze anodised finish m2 156.92

I200018 Black anodised finish m2 164.48

I200019 Polyester powder coated finish m2 161.57

I200020 Fluorocarbon coated finish m2 180.14


Aluminium framed adjustable glass louvres windows complete
with aluminium hollow section frames around and
intermediate section, polypropylene glass holders with UV
stabiliser, fixing straps, vinyl weather strips including
building-in and pointing frames (glass measured separately)

I200021 Natural anodised finish m2 141.59

I200022 Bronze anodised finish m2 162.65

I200023 Black anodised finish m2 170.42

I200024 Polyester powder coated finish m2 166.10

I200025 Fluorocarbon coated finish m2 186.08

Galvanised steel adjustable louvred window frames with 6mm


thick clips to receive 150mm louvre blades including screws
to match (louvre blades measured separately)

I200026 Set of galvanised steel frames (control measured separately) m 15.60

I200027 Extra over for frames for each control mechanism No. 1.51

BW-I2
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I200000 WINDOWS (CONT'D)

Aluminium adjustable louvred window frames complying with


SS 212 with polypropylene glass holders/blade clips including
screws to match (louvre blades measured separately)

I200028 Set of natural anodised aluminium frames (control measured m 36.94


separately)

I200029 m 38.88
Set of bronze or black anodised aluminium frames (control
measured separately)
I200030 m 42.77
Set of powder coated aluminium frames (control measured
separately)

I200031 Extra over items (I200028) - (I200030) for each control mechanism No 1.94

1.63mm (16 gauge) aluminium louvre blades fixed to blade


clips of frames or grooves in timber with aluminium rivets or
bolts and washers including preparing or cleaning clips or
grooves and drilling

I200032 100mm wide natural anodised aluminium louvre blades m 9.29

I200033 150mm wide natural anodised aluminium louvre blades m 13.07

I200034 150mm wide bronze or black anodised aluminium louvre blades m 14.36

I200035 150mm wide powder coated aluminium louvre blades m 14.36

Burglar-proof bars fixed to and including holders of aluminium


louvred frames

I200036 10mm square mild steel bars m 2.81

I200037 12.5mm diameter aluminium bars m 3.46

Weather strips
I200038 m 4.10
0.56mm (24 gauge) approved metal weather strips (any approved
type and width) fixed to window sills

BW-I3
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I300000 DOORS

Heavy duty aluminium framed louvred doors comprising of 50


x 45 x 1.83mm thick aluminium vertical stiles, 80 x 45 x 2.3mm
thick aluminium top and centre rails, 50 x 45 x 2.3mm thick
aluminium bottom rails, 75mm girth x 3mm thick aluminium
louvred blade infills, 38 x 3mm thick aluminium bracing
complete with approved hinges, 150mm bolts and heavy duty
hasp and staple including 102 x 50 x 3mm thick and 50 x 25 x
2mm thick aluminium hollow section door frames and
including fixing frames to walls

I300001 Natural anodised finish


m2 339.34
I300002 Bronze anodised finish m2 363.53

I300003 Black anodised finish m2 399.92

I300004 Polyester powder coated finish m2 372.06


m2 427.90
I300005 Fluorocarbon coated finish

Aluminium framed sliding doors (approved thickness) in


single or multiple leaves with vinyl glazing gasket to receive
glass, complete with door frames including waterproof
cement fillet, vinyl weather strip all round, tracks, channels,
nylon rollers, guides, concealed hook, cylinder lock operated
by latch or by key and all other necessary accessories (glass
measured separately)

I300006 Natural anodised finish


m2 143.96
I300007 Bronze anodised finish m2 151.20

I300008 Black anodised finish m2 158.76

I300009 Polyester powder coated finish m2 157.90


m2 173.66
I300010 Fluorocarbon coated finish

Aluminium framed glazed swing door and frames with


weather strip all round and gasket to receive glass complete
with all necessary floor springs, locks and 200mm high
push/pull plates (glass measured separately)

I300011 Natural anodised finish


m2 207.90
I300012 Bronze anodised finish m2 215.14

I300013 Black anodised finish m2 222.91

BW-I4
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I300000 DOORS (CONT'D)

Aluminium framed glazed swing door and frames with


weather strip all round and gasket to receive glass complete
with all necessary floor springs, locks and 200mm high
push/pull plates (glass measured separately) (Cont'd)

I300014 Polyester powder coated finish m2 221.51


m2 237.28
I300015 Fluorocarbon coated finish

Aluminium toilet doors

I300016 40mm thick aluminium flush doors fabricated of foam infill lined m2 188.14
both sides with 1.20mm (18 gauge) natural anodised aluminium
lining complete with hinges and locks

I300017 1.22mm (18 gauge) aluminium doors in one or two leaves m2 83.59
complete with hinges, bolts and all necessary fittings

Mild steel grille doors and frames in welded construction


including applying one coat of inhibitive primer before
delivery and one undercoat and one finishing coat of enamel
paint after installation

I300018 Swing grille doors fabricated of 25 x 25 x 2mm hollow sections m2 76.46


surround and 25 x 6mm flats fixed vertically spaced at 500mm
centres infilled with 19 x 6mm flats arranged diagonally spaced at
80mm centres complete with hinges, locks and including 25 x 25 x
3mm angle door frames

m2 118.69
I300019 Swing grille doors fabricated of 25 x 25 x 2mm hollow sections
surround and fixed vertically spaced at 500mm centres infilled with
19 x 6mm flats spaced at 100mm centres complete with hinges,
locks and including 32 x 32 x 3mm angle door frames

I300020 Sliding grilled doors fabricated of 25 x 25 x 2mm hollow sections m2 130.90


surround and 25 x 6mm flats fixed vertically spaced at 500mm
centres infilled with 19 x 6mm flats arranged diagonally spaced at
80mm centres complete with locks, sliding track consisting 65 x
38mm 'U' channel at top and 30 x 18mm 'U' channel at the bottom,
rollers and guides including 50 x 50 x 4mm hollow section door
frames

I300021 Sliding grille doors fabricated of 38 x 38 x 3mm hollow sections m2 92.62


surround infilled with 19 x 4.5mm flat bars bent to approved
ornamental shape or design, complete with locks, sliding track,
rollers and guides including 38 x 38 x 3mm thick angle door
frames

BW-I5
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I300000 DOORS (CONT'D)

Mild steel grille doors and frames in welded construction


including applying one coat of inhibitive primer before
delivery and one undercoat and one finishing coat of enamel
paint after installation (Cont'd)

I300022 Sliding grille doors fabricated of 38 x 38 x 3mm hollow sections m2 118.47


surround with 25 x 6mm flats fixed vertically spaced at 600mm
centres infilled with 19 x 6mm flats spaced at 80mm centres
complete with locks, sliding tracks consisting of 65 x 38mm 'U'
channel at top and 36 x 19mm hollow section at bottom, rollers
and guides including 38 x 38 x 3mm thick angle door frames

I300023 Sliding grille doors fabricated of 25 x 25 x 3mm thick hollow m2 83.38


sections surround, 25mm x 6mm flats fixed vertically spaced at
600mm centres infilled with 10 x 10mm square bars arranged
diagonally spaced at 80mm centres complete with locks, sliding
track, roller and guides including 25 x 25mm x 3mm thick hollow
section door frames

Cellular foam pvc flush doors complete with upvc door


frames

I300024 Folding doors complete with hinges and approved locksets


m2 121.18
m2 151.20
I300025 Flush doors complete with hinges and approved locksets

Fibreglass doors complete with door frames

I300026 Fibreglass doors complete with hinges and approved locksets m2 134.68

Door frames

I300027 1.30mm thick zinc coated steel sheet pressed door frames, twice m 38.90
rebated, built into concrete or brick walls and grouted to solid with
cement mortar

BW-I6
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I400000 ROLLER SHUTTERS

Manually operated aluminium roller shutters with 1.2mm thick


laths complete with spring barrel assembly on top, bolted to
concrete lintol and encased with not less than 1mm thick
sheet including guides and brackets to concrete, lifting
handles at bottom rails and fitting with roller shutter locks or
brass slop bolts at both ends of bottom rail with padlock
brackets and necessary punching of holes on slats. (padlock
measured separately) (extreme size of roller shutter including
box assembly and side frames shall be measured)

I400001 Natural anodised finish


m2 171.72
I400002 Bronze anodised finish m2 194.40

I400003 Black anodised finish m2 210.60

I400004 Powder coated finish m2 183.60

Manually operated colorbond zincalume steel roller shutters


with 1.2mm thick perforated slats complete with spring barrel
assembly on top, bolted to concrete lintol and encased with
not less than 1mm thick sheet including guides and brackets
to concrete, lifting handles at bottom rails and fitting with
roller shutter locks or brass slop bolts at both ends of bottom
rail with padlock brackets and necessary punching of holes
on slats. (padlock measured separately) (extreme size of roller
shutter including box assembly and side frames shall be
measured)

I400005 Powder coated finish


m2 297.00
I400006 Natural anodised finish m2 145.15

I400007 Bronze anodised finish m2 167.40

I400008 Powder coated finish m2 272.16

I400009 Extra over chain block operated type roller shutters No 594.00
No 1,603.80
I400010 Extra over app ro ve d ele ctrically ope rat ed moto r f or rolle r
shutter/grilles including up-down-stop push button control with
locking device, short length of electrical cable connection but
excluding power point

BW-I7
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I400000 ROLLER SHUTTERS (CONT'D)

Manually operated aluminium roller grilles with 1.2mm thick


slats complete with spring barrel assembly on top, bolted to
concrete lintol and encased with not less than 1mm thick
sheet including guides and brackets to concrete, lifting
handles at bottom rail with padlock brackets and necessary
punching of holes on slats. (padlock measured separately)
(extreme size of roller shutter including box assembly and
side frames shall be measured)

I400011 Additional up-down-stop push button control switch in control room No 237.60
including wiring from roller shutter/grilles

I500000 ANGLE GUARDS

I500001 50 x 50 x 6mm thick mild steel angle guards 1000mm high with No 19.98
two 25 x 3mm x 225mm long fixing lugs, set flush cast into
concrete or drilled and bolted to brickwork

I600000 BALUSTRADES AND HANDRAILS

Mild steel balustrades in welded construction including


labours for forming bends, ramps, wreaths, etc

I600001 50mm tubular handrails or bottom rails welded to balusters m 38.12


including running joint

I600002 38mm tubular balusters x 900mm long, one end split and cast into No 26.89
concrete stringer and grouted in cement mortar (1:3)
No 7.34
I600003 20 x 5mm flat balusters x 600mm long

Hairlined stainless steel balustrades or railings in welded


construction including labours for forming bends, ramps,
polishing and hacking off concrete

I600004 20mm tubular x 1.6 mm thick handrails, balustrades, etc. m 34.02


I600005 32mm tubular x 1.6 mm thick handrails, balustrades, etc. m 46.66

I600006 38mm tubular x 1.6 mm thick handrails, balustrades, etc. m 56.38

I600007 50mm tubular x 1.6 mm thick handrails, balustrades, etc. m 66.10

I600008 75mm tubular x 1.6 mm thick handrails, balustrades, etc. m 77.76


No 14.58
I600009 Stainless steel brackets with bolts and nuts including chasing in
concrete if necessary

BW-I8
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I600000 BALUSTRADES AND HANDRAILS (CONT'D)

Hairlined stainless steel balustrades or railings in welded


construction including labours for forming bends, ramps,
polishing and hacking off concrete (Cont'd)

I600010 Supply and fix 20 mm diameter x 1.6mm thick stainless steel rails, m 34.10
balustrades etc including bend, ramps including full welded joints,
polish and hacking of concrete

I600011 Ditto 32mm diameter x 1.6mm thick ditto


m 46.70
I600012 Ditto 38mm diameter x 1.6mm thick ditto m 56.40

I600013 Ditto 50mm diameter x 1.6mm thick ditto m 66.10


m 77.76
I600014 Ditto 75mm diameter x 1.6mm thick ditto

Galvanised mild steel safety railings in welded construction

I600010 Galvanised mild steel safety railings in welded construction not m 118.80
exceeding 1000mm high; each section comprising of 40mm
tubular framings surround not exceeding 3.00m centres to centres
and infilled with vertical 12mm square bars fixed at 150mm
centres and and welded to 40 x 6mm flat bars surround; each
section of the railing shall be provided with two 40mm tubular
posts not exceeding 250mm high welded to 200 x 200 x 8mm thick
base plates embedded into and including concrete foundation, four
rail bolts to each foundation and applying one coat of inhibitive
primer and two finishing coats of enamel paint

I700000 GRATINGS, COVERS AND FRAMES

Mild steel gratings and frames in welded constru ction


including painting with one coat of inhibitive primer prior to
delivery

I700001 Mild steel gratings in panels fabricated of 25 x 25 x 3mm angle m2


framing infilled with 20 x 3mm flats and 20 x 5mm flats (angle
frames to receive gratings measured separately) 60.59

I700002 Mild steel gratings in panels fabricated of 50 x 50 x 4mm angle


framing infilled with 50 x 8mm flats and 13mm diameter transverse
bars threaded across (angle frames to receive gratings measured m2
separately) 188.35

BW-I9
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I700000 GRATINGS, COVERS AND FRAMES (CONT'D)

Mild steel gratings and frames in welded construction


including painting with one coat of inhibitive primer prior to
delivery (Cont'd)

I700003 Mild steel gratings in panels fabricated of 40 x 10mm flat surround m2 157.46
infilled with 40 x 10mm flats spaced at 50mm centres and 13mm
diameter transverse bars threaded across spaced at 200mm
centres (angle frames to receive gratings measured separately)

I700004 Add to above items (I700001) to (I700003) f or hot -dipped m2 42.88


galvanised steel

I700005 Heavy duty mild steel gratings and frames consisting of 40 x m2 306.07
15mm flats surround infilled with 25 x 15mm flats spaced at 40mm
centres and 25 x 6mm transverse flats including 50 x 50 x 6mm
angle frames embedded in concrete

I700006 Light duty mild steel gratings in panels fabricated of 50 x 50 x 6mm m2 112.00
angle framing infilled with 40 x 6mm flats spaced at 46mm centres

I700007 Add to abo ve ite ms (I 70 0005 ) & (I7 000 06) f or h o t -dip ped m2 65.99
galvanising steel

I700008 Galvanised mild steel gratings in panels fabricated of 50 x 6mm m2 241.81


flats surround infilled with 50 x 6mm flats spaced at 50mm centres
and two 13mm diameter transverse bars threaded across including
65 x 65 x 6mm angle framing embedded in concrete

I700009 Galvanised steel gratings in panels fabricated of 34 x 6mm flats m2 288.79


surround infilled with 34 x 6mm flats spaced at 25mm centres and
10mm diameter transverse bars threaded across including 40 x 40
x 6mm angle frames embedded in concrete

I700010 Galvanised hinged mild steel gratings in panels fabricated of 32 x m2 290.63


6mm flat perimeter framing infilled with 32 x 6mm flats spaced at
25mm centres and 10mm diameter transverse bars threaded
across fitted with hinged devices on the other side, 3mm thick
chequered plate placing on including 51 x 38 x 6mm angle
framings embedded in concrete

I700011 Galvanised hinged mild steel gratings in panels fabricated of 34 x m2 305.96


6mm flats surround infilled with 34 x 6mm flats spaced at 25mm
centres and 10mm diameter transverse bars threaded across fitted
with hinged devices on the other side including 50 x 40 x 6m angle
framings embedded in concrete

I700012 Galvanised steel gratings in panels fabricated of 34 x 6mm flats m2 201.10


surround infilled with 25 x 6mm flats spaced at 25mm centres
including 40 x 40 x 6mm angle frames embedded in concrete

BW-I10
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I700000 GRATINGS, COVERS AND FRAMES (CONT'D)

Mild steel angle framings to receive gratings with 25 x 6mm


fishtailed flat bar 75mm long as holding down lugs welded at
600mm centres and built into concrete surround including
forming mortices, grouting around lugs in cement mortar
(1:3); making good work disturbed and painting with one coat
of inhibitive primer

I700013 40 x 40 x 6mm thick


m 6.37
m 8.10
I700014 50 x 50 x 6mm thick

Galvanised steel angle framings to receive gratings with 25 x


6mm fishtailed flat bar 75mm long as holding down lugs
welded at 600mm centres and built into concrete surround
including forming mortices, grouting around lugs in cement
mortar (1:3); making good work disturbed and painting with
one coat of inhibitive primer

I700015 40 x 40 x 6mm thick


m 7.56
m 9.72
I700016 50 x 38 x 6mm thick

Nylon reinforced fibreglass gratings and frames

I700017 Nylon fibreglass reinforced grating with nylon reinforced fibreglass m 278.64
heavy-duty angle frame 650mm wide x 600 kg

I 8 0 0 0 0 0 G RI L LE S

Mild steel grilles in welded construction, fixing to woodwork,


brickwork, concrete work or counter top etc. and applying
one coat of inhibitive primer before delivery and one
undercoat and one finishing coat of enamel paint after
installation

I800001 Mild steel grilles comprising of 25 x 6mm flats surround and fixed m2 64.69
vertically at 500mm centres and infilled with 9mm square bars
arranged diagonally at 80mm centres

I800002 Mild steel grilles fabricated of 17 x 4mm flats surround and fixed m2 53.46
vertically at 750mm centres and infilled with 17 x 4mm flats
arranged diagonally at 82mm centres

I800003 Mild steel grilles fabricated of 25 x 6mm flats surround and 20 x m2 72.90
4.5mm flats fixed vertically at 350mm centres and horizontally at
105mm centres

I800004 Mild steel grilles fabricated of 19 x 6.4mm flats vertically at 120mm m2 82.62
centres and horizontally at 300mm centres and including 6mm
diameter x 50mm retraction bolts placed at 300mm centres

BW-I11
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I800000 GRILLES (CONT'D)

Mild steel grilles in welded construction, fixing to woodwork,


brickwork, concrete work or counter top etc. and applying
one coat of inhibitive primer before delivery and one
undercoat and one finishing coat of enamel paint after
installation (Cont'd)

I800005 Mild steel grilles fabricated of 20 x 6mm flats surround and fixed m2 58.32
vertically at 800mm centres and infilled with 16 x 4mm flats
arranged diagonally

I800006 Mild steel grilles fabricated of 25 x 6mm flats surround infilled with m2 69.98
19 x 4mm flats bent to approved ornamental shape or design

I800007 Mild steel grilles fabricated of 25 x 6mm flats surround infilled with m2 63.18
17 x 4mm flats bent to approved ornamental shape or design

I800008 Mild steel grilles fabricated of 15 x 4.5mm flats surround infilled m2 82.30
with 15 x 4.5mm flats bent to approved ornamental shape or
design

Aluminium grilles fixing to woodwork, brickwork, concrete


work or counter top etc.

I800009 Natural anodised fixed aluminium grilles fabricated of 15 x 15mm m2 91.80


square hollow section surrounds and infilled with 8mm diameter
mild steel insets spaced at 150mm centres

I800010 Powder coated fixed aluminium grilles fabricated of 15 x 15mm m2 100.98


square hollow section surrounds and infilled with 8mm diameter
mild steel insets spaced at 150mm centres

I800011 1.22mm thick (18 gauge) fixed aluminium ornamental grilles m2 83.80
fabricated of 76 x 44mm hollow sections surround infilled with 19 x
3mm flats bent to approved ornamental shape or design

I800012 Bronze anodised fixed aluminium grilles fabricated of 30 x 30mm m2 136.08


hollow section surround infilled with approved ornamesh including
U-channel edging and rivets

I800013 Bronze anodised sliding aluminium grilles fabricated of 30 x 30mm m2 146.99


hollow section surround infilled with approved ornamesh with and
including approved lock, tracks, roller guides and all necessary
accessories

I800014 Bronze anodised sliding aluminium grille doors and frames m2 197.96
fabricated of 30 x 30mm hollow section surround infilled with
approved ornamesh and door frames with and including approved
lock, tracks, roller guides and all necessary accessories

BW-I12
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I900000 METAL STUD PARTITION FRAMING

Demountable partition framing (for full height lining) with an


overall thickness of not more than 75mm, comprising of mild
steel studs or galvanised steel studs with exposed anodised
aluminium framing spaced at 600mm centres at both ways,
corner and end posts, anodised aluminium ceiling and floor
tracks to receive lining and fixed complete with approved
vinyl insert, door frames, if any, 100mm high aluminium
skirting and other recommended accessories. (wallboard
lining measured separately)

I900001 Demountable stud partition framing


m2 22.33
I900002 Demountable stud partition framing with fanlights m2 28.30
m2 #REF!
I900003 Demountable stud partition framing in two panels with top or both
panels open to receive glass and bottom panels open to receive
lining and fixed complete with approved vinyl insert, 100mm high
aluminium skirting, door frames, if any, transomes and other
recommended accessories

I900004 Demountable stud partition framing with fanlights in two panels m2 28.30
with top or both panels open to receive glass and bottom panels
open to receive lining and fixed complete with approved vinyl
insert, 100mm high aluminium skirting, door frames, if any,
transomes and other recommended accessories

I900005 Vinyl 'U' shaped gasket to receive glass in new or in replacement m 0.38
including taking out existing and making good surround

J900006 75mm high black vinyl skirtings to demountable partitions including m 1.73
adhesive

I900007 100mm high black vinyl skirtings to demountable partitions m 2.16


including adhesive

I900008 100mm high anodised aluminium skirtings with vinyl insert to m 4.10
demountable aluminium partitions

I900009 100mm high anodised aluminium skirtings with vinyl insert to m 4.43
demountable aluminium partitions but in replacement including
taking down existing and removing off site

Extra over demountable partitions for 40mm thick door


covered on both sides with and including 13mm thick plain
gypsum wallboard linings finished with 2 coats of emulsion
paint (ironmongery measured separately)

I900010 Single leaf flush doors with or without vision panels


m2 92.02
I900011 Single leaf flush doors with louvred vent not exceeding 0.50m2 m2 135.65

BW-I13
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I900000 METAL STUD PARTITION FRAMING (CONT'D)

Extra over demountable partitions for 40mm thick door


covered on both sides with and including 13mm thick plain
gypsum wallboard linings finished with 2 coats of emulsion
paint (ironmongery measured separately) (Cont'd)

I900012 Double leaf flush doors with or without vision panels m2 131.76

I900013 m2 145.37
Single or double leaf panelled doors top panel opened to receive
glass (rate includes glass) and bottom to receive lining including
vinyl glazing gaskets

I900014 Extra over single leaf doors for aluminium edging m2 17.17

I900015 Extra over double leaf doors for aluminium edging m2 19.55

Extra over demountable partitions for 40mm thick door


covered on both sides with and including 13mm thick vinyl
faced gypsum wallboard linings

I900016 Single leaf flush doors with or without vision panels m2 103.57

I900017 Single leaf flush doors with louvred vent not exceeding 0.50m2 m2 146.88

I900018 Double leaf flush doors with or without vision panels m2 139.86
I900019 m2 154.87
Single or double leaf flush doors, top panel opened to receive
glass (rate includes glass) and bottom to receive lining including
vinyl glazing gasket

Extra over demountable partitions for 40mm thick door


covered on both sides with and including 6mm thick teak
veneered plywood

I900020 Single leaf flush doors with or without vision panels m2 92.02

I900021 Single leaf flush doors with louvred vent not exceeding 0.50m2 m2 135.65

I900022 Double leaf flush doors with or without vision panels m2 131.76
I900023 m2 145.37
Single or double leaf flush doors, top panel opened to receive
glass (rate includes glass) and bottom to receive lining including
vinyl glazing gasket

I900024 Extra over single leaf doors for aluminium edging m2 17.17

I900025 Extra over double leaf door for aluminium edging m2 19.55

BW-I14
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I900000 METAL STUD PARTITION FRAMING (CONT'D)

Natural anodised aluminium framed glazed partition divided


into one or multiple panels and fan lights comprising 75 x
40mm stud framings spaced at not more than 1200mm
centres complete with weather strip all round, gasket to
receive glass and 100mm high aluminium skirtings (glass
measured separately)

I900026 Stud partition framing m2 94.07

I900027 Stud partition framing with aluminium fascia m2 121.07

I900028 Stud partition framing with 100 x 40mm studs m2 118.15

I1000000 PROPRIETARY DEMOUNTABLE PARTITIONS

I1000001 Movable acoustic partition system (STC 51dB) constructed from m2 631.26
100mm thick panel with 16mm thick free-oscillating particle board
on both sides and incorporating with mechanical operated top and
bottom retractable sound seals and suspended at two points by
ball rollers; all aluminium sides trims shall be natural anodised
incorporating interpolating magnetic strips and vinyl seals

I1000002 Extra over partitions for pass door


No 1,944.00

I1100000 AWNING

0.56mm thick (24 gauge) crimped pattern multi -coloured


aluminium awning comprising of sheeting in narrow widths
with ends and side laps and over -hangs, fixed on and
including framing and welded trusses, or on other approved
steel framed and welded trusses

I1100001 Awning fixed on and including 25mm tubular or 25 x 25mm square


hollow section framing
m2 75.82
I1100002 Awning fixed on and including 38mm tubular or 38 x 38mm square
hollow section framing

Eclipse awning of approved type consisting of aluminium m2 83.48


panels fixed to and including stringers/carriers, painted mild
steel hollow section frames and trusses (area measured on
plan)

I1100003 0.50mm thick


I1100004 0.60mm thick

m2 117.61
m2 138.56

BW-I15
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I1200000 ALUMINIUM FASCIA

I1200001 0.91mm (20 gauge) rolled aluminium sheet panelling well lapped
at joints and fixed to hollow section railing with stainless steel self m2 194.40
tapping screws, as fascia, railing, etc. including all cutting, waste
and drilling. (measured nett - no allowance made

I1300000 ALUMINIUM SUNBREAKER

I1300001 Sunbreaker comprising of 1.20mm (18 gauge) fixed plai n or


extruded aluminium louvres 100mm wide, bent as necessary with m2 158.44
all edges beaded, soldered fixed at 60 degrees to and including 75
x 45mm aluminium hollow sections surround and mullions
consisting of 75 x 25mm 'U' channel fixed to and including 75 x
45mm aluminium hollow sections at 900mm centres

I1300002 Approved aluminium sunbreaker ('U' profile) comprising of baked


enamelled louvred panels (0.6mm thick) and stringers, complete m2 9.04
with anodised aluminium hollow section frames and struts, wall
brackets, approved bolts, screws, etc. and all other necessary
accessories

I1300003 Approved aluminium sunbreaker ('Z' profile) comprising of


extruded aluminium louvred panels (0.6mm thick) complete with m2 138.24
anodised aluminium frames, profile cap, panel locks, brackets
locks, panel brackets and all other necessary accessories

I1400000 MISCELLANEOUS METALWORK

Natural anodised aluminium section cut to required lengths,


fixed to brickwork, concrete etc including bending, welding
and drilling holes, etc

I1400001 20 x 20 x 1mm square hollow sections


m 6.70
I1400002 25 x 25 x 1mm square hollow sections
m 7.99
I1400003 50 x 50 x 2mm square hollow sections
m 26.57
I1400004 75 x 75 x 2mm square hollow sections
m 28.62
I1400005 100 x 100 x 3mm square hollow sections
m 30.67
I1400006 13 x 25 x 1.5mm rectangular hollow sections
m 5.72
I1400007 38 x 25 x 1.5mm rectangular hollow sections
m 7.78
I1400008 50 x 25 x 1.5mm rectangular hollow sections

I1400009 75 x 25 x 3mm rectangular hollow sections m 8.42

m 21.38

BW-I16
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I1400000 MISCELLANEOUS METALWORK (CONT'D)

Natural anodised aluminium section cut to required lengths,


fixed to brickwork, concrete etc including bending, welding
and drilling holes, etc (Cont'd)

I1400010 75 x 50 x 3mm rectangular hollow sections m 26.78

I1400011 100 x 50 x 3mm rectangular hollow sections m 32.18

I1400012 6 x 6 x 1.2mm channels m 3.13

I1400013 10 x 10 x 1.2mm channels m 5.51

I1400014 13 x 13 x 1.2mm channels m 5.83

I1400015 16 x 16 x 1.2mm channels m 6.26

I1400016 19 x 19 x 1.2mm channels m 6.80

I1400017 25 x 25 x 1.2mm channels m 7.67

I1400018 50 x 25 x 1.2mm channels m 8.21

I1400019 75 x 25 x 1.2mm channels m 11.12

I1400020 10 x 10 x 1.2mm angles m 5.18

I1400021 13 x 13 x 1.2mm angles m 5.40

I1400022 16 x 16 x 1.2mm angles m 5.62

I1400023 19 x 19 x 1.2mm angles m 5.83

I1400024 25 x 25 x 3mm angles m 6.59

I1400025 32 x 32 x 3mm angles m 6.48

I1400026 38 x 38 x 3mm angles m 8.10

I1400027 50 x 50 x 3mm angles m 9.29

Chequer plates cut to required sizes and fixed to concrete,


etc including bending, welding and drilling holes, etc

I1400028 3mm thick mild steel chequer plates m2 96.55

I1400029 6mm thick mild steel chequer plates m2 185.65

I1400030 3mm thick aluminium chequer plates m2 158.65

I1400031 6mm thick aluminium chequer plates m2 310.39

BW-I17
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I1400000 MISCELLANEOUS METALWORK (CONT'D)

Sundries

I1400032 38 x 3mm galvanised wrought iron or primed mild steel holdfast No 0.65
225mm long, one end turned up and screwed to timber and other
end split and built into brickwork
I1400033 No 0.65
Mild steel dowels not exceeding 12mm diameter x 150mm long
fixed to foot of wood frames

I1400034 No 0.76
40 x 3mm mild steel cramps 225mm girth once bent, one end split
and fixed in brickwork and other end screwed to wood frame

I1400035 Mild steel straps (to fasten foot of wooden posts etc) not exceeding No 8.53
50 x 6mm x 600mm long holed for and including two steel bolts
with nuts and washers including casting one end in concrete

I1400036
6mm thick mild steel shoe of purpose-made design (any size) for
No #REF!
holding timber purlins, rafters, joists, etc.

I1400037 Aluminium rivets to linings (any type) No #REF!


I1400038 kg #REF!
Mild steel rag bolts (irrespective of sizes and lengths) with nut and
washers including temporary boxing to form holes, building in and
grouting

I1400039 75 x 75 x 6mm mild steel angle cleats not exceeding 200mm long No 3.24

I1500000 CLADDING SYSTEMS


Wall claddings with and including galvanised mild steel sub-
frame brackets or runners

I1500001 3mm powder coated aluminium panels m2 186.73


I1500002 3mm fluorocarbon coated aluminium panels m2 203.04

I1600000 SHELVINGS

Approved stove enamel slotted angle in shelving and


equipment frames, etc. (any size and design)
Note: Any length under (300mm) shall be counted as
(300mm)

I1600001 40 x 40 x 2mm slotted angles m 3.46

BW-I18
I : METAL WORK
I1600002 62 x 41 x 2mm slotted angles m 4.21

BW-I19
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I1600000
SHELVINGS (CONT'D)

Approved stove enamel slotted angle in shelving and


equipment frames, etc. (any size and design) (Cont'd)
Note: Any length under (300mm) shall be counted as
(300mm)

I1600003 38 x 2mm with 10mm holes punched steel strap angles No 4.21

I1600004 34 x 15 x 2mm with 10mm holes bracing angles No 4.21

Approved steel panels (shelves) with zinc phosphated or


stove enamelled battleship grey finish for use with slotted
angle sections

I1600005 750 x 300mm No 11.66

I1600006 750 x 450mm No 12.31

I1600007 900 x 300mm No 13.28

I1600008 900 x 450mm No 19.66

I1600009 900 x 600mm No 21.92

I1600010 900 x 900mm No 33.37

Approved steel panels (shelves) for heavy shelving bolted


directly to horizontal beams

I1600011 900 x 150mm panels with stove enamelled finish No 5.50

I1600012 900 x 150mm panels with aluminium alloy finish No 7.34

Approved perforated steel shelf dividers with etch-primed or


stove enamelled battleship grey finish

I1600013 300 x 140mm No 2.81

I1600014 300 x 215mm No 3.20

I1600015 450 x 140mm No 3.70

I1600016 450 x 215mm No 4.00

I1600017 Approved zinc plated steel adjuster clips No 0.54

I1600018 Approved stove enamelled finished steel corner plates No 0.32

BW-I20
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I 1 7 00 0 0 0 S AFE

I1700001 Safe 880 x 616 x 629mm secured by one key lock and keyless No 2,235.60
combination locks

I1800000 RAISED ACCESS FLOOR SYSTEM

600 x 600mm cementitious infill steel panels with flathead


pedestals and galvanised steel stringer free -laid onto
pedestal heads finished floor height 150mm

I1800001 Bare finish


m2 132.00
I1800002 High pressure laminate finish m2 114.00

Supply and install 600mm x 600mm perforated raised floor with m2 252.00
cement infill and finish high pressure lamination
-
*
Underflow insulations
m2
I1800003 25mm thick close-cell rigid phenolic foam (40kg/m3 density) with 62.10
0.40mm thick laminated glass fibre reinforced aluminium foil and
glass tissue

I1800004 Supply of double cup panel lifter


No 95.37
I1800005 Labour and tools to cut opening to fit compartment service outlet No 26.40
boxes and the likes

I1900000 FLAGPOLES

I1900001 Galvanised mild steel tapered flagpoles of 6000mm high from No 1,570.75
ground with 90mm bottom diameter x 75mm top diameter
complete with belaying cleats, brass pulley , approved woven
nylon halyard, brackets and setting flagpoles not exceeding
1000mm into ground including concrete base (grade 20),
excavation and painting with three coats of paint

I1900002 Anodised aluminium tapered flagpoles of 6000mm high from No 1,657.15


ground with 100mm bottom diameter x 75mm top diameter
complete with belaying cleats, brass pulley , approved woven
nylon halyard, brackets and setting flagpoles not exceeding
1000mm into ground including concrete base (grade 20),
excavation and painting with three coats of paint

I1900003 Stainless steel tapered flagpoles of 6000mm high from ground with No 1,799.93
100mm bottom diameter x 75mm top diameter complete with
belaying cleats, brass pulley , approved woven nylon halyard,
brackets and setting flagpoles not exceeding 1000mm into ground
including concrete base (grade 20) and excavation

BW-I21
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I2000000 LECTURE THEATRES SEATINGS

I2000001 Beam mounted one piece injection moulded polypropylene seat No 207.90
complete with A3 size foldable 300 x 425 x 10mm injected
moulded polypropylene writing tablet with epoxy powder coated
finish heavy duty die cast aluminium alloy, fitted with anti-shock
end caps

I2100000 FABRIC ACOUSTIC WALL LINING SYSTEM

I2100001 Acoustic fabric wall lining system consisting 50 x 50mm tanalised m2 211.14
timber battens fixed to concrete or brickwalls with 50mm thick
fibreglass of 60 kg/m3 density) infill secured onto timber stud lined
with fabric and 9mm thick flange pvc perimeter frame

I2200000 ACOUSTIC WALL PANELLING

I2200001 Acoustic wall panelling consisting of prefinished vinyl coated steel m2 118.48
slats complete with hot dipped galvanised fixing channels,
compressible glass fibre infills, capping, textile inlay and 25mm
thick rockwool inlay (60kg/m3 density)

I2300000 BOLLARDS

I2300001 150mm diameter mild steel tubular bollards 1200mm high from No 48.60
ground level including embedding 300mm in concrete foundation
including painting with one coat inhibitive primer and two finishing
coats of aluminium/enamel paint (concrete foundation measured
separately)

I2300002 230mm diameter fibreglass bollards with reflective sheetings No 432.00


1000mm high housed into 205mm diameter x 6mm mild steel
tubular with 300 x 300 x 6mm flange plates with four 12mm
diameter masonry bolts bolted to concrete

I2400000 BOLTS WITH NUTS AND WASHERS

I2400001 6mm diameter zinc plated hexagonal headed type No 0.38


I2400002 8mm diameter zinc plated hexagonal headed type No 0.38

I2400003 8mm diameter zinc plated or sheradized type No 0.27


I2400004 8mm diameter high tensile type No 0.38
I2400005 9mm diameter stainless steel type x 350mm long No 19.44

BW-I22
I : METAL WORK

ITEM NO. DESCRIPTION UNIT RATE


(S$)

I2500000 ROOF TRAP DOORS

I2500001 6mm thick mild steel roof trap doors with 38 x 38mm mild steel angle
framing all round complete with hinges, hasp and staple (padlock m2 224.21
measured separately) rest on and including 50 x 50mm mild steel
angle fixed to concrete work or the like and three coats

I2500002 Roof trap doors with 18mm thick plywood backing, and covered all
round with 0.56mm (SWG 24) aluminium sheeting, complete with m2 139.21
hinges, hasp and staple (padlock measured separately), rest on
and including 50 x 50 x 6mm mild steel angle fixed to concrete
work or the like and three coats of enamel paint

I2500003 50mm thick access trap door comprising of 1.2mm thick anodised
aluminium alloy sheets on both faces supported with 38 x 20 x m2 391.82
1.2mm thick galvanised steel "C" channel bracings and 60 x 38 x
1.2mm thick galvanised steel "C" channel framings infilled with
rockwool insulation complete with guides, tracks, rollers, bolts, etc
including hasp and staple

I2600000 MILD STEEL VEHICULAR RAMPS

J2600001 Mild steel vehicular ramps fabricated on 6mm chequer plates


complete with framings m2 302.40

BW-I23
SECTION J: WALL & CEILING FINISHINGS
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J100000 DEMOLITION / ALTERATIONS

Removing existing wall finishes of any thickness in whole or


in patch including removing debris off site and preparing
surfaces to receive new

J100001 Existing plastering


m2 4.80
m2 6.16
J100002 Existing wall tiling, granite/marble cladding or other similar
materials including rendered backing

J100003 Existing moulded cornice, architrave, etc. not exceeding 150mm m 0.54
girth

J100004 Removing damaged pointing and repointing in ordinary Portland m2 3.72


cement, white or coloured cement to joints of existing wall tilings or
stone finishes

J100005 Taking out fabric or vinyl coverings on wall; removing off site and m2 2.40
preparing surfaces to receive new

Removing existing ceiling linings in whole or in patch


including removing debris off site and preparing to receive
new

J100006 Existing ceiling board linings


m2 1.08
J100007 Existing ceiling board linings including suspension system m2 3.24

J100008 Taking out existing ceiling board linings; set aside for reuse m2 0.76

J 100009 Taking from stack and refixing suspended ceiling board linings m2 1.30
m2 12.42
J100010 Taking down false ceiling including timber or metal bearers and
rebuild, using the same materials and removing debris off site
(new materials measured separately)

J100011 Replacing defective or missing aluminium or galvanised steel m 3.89


suspension tees including annealed wire and removing old
materials off site

J200000 IN-SITU FINISHES

Cement and sand (1:4) plastering with approved plasticiser


on concrete or brick walls, columns, ceilings, beams,
windows, sills, etc

J200001 13mm thick in one coat with steel trowelled finish


m2 9.00
J200002 20mm thick in two coats with steel trowelled finish m2 10.32

BW-J1
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J200000 IN-SITU FINISHES (CONT'D)

Cement and sand (1:4) plastering with approved plasticiser


on concrete or brick walls, columns, ceilings, beams,
windows, sills, etc

J200003 Extra over above items (J200001) & (J200002) for laying in m2 0.60
patches, each patch not exceeding 1 m2

Labour and materials for forming moulded cornice,


architrave, etc.

J200004 Not exceeding 150mm girth


m 3.36
J200005 Ditto including hacking out existing and removing debris off site m 3.72

J200006 Exceeding 150mm and not exceeding 300mm girth m 7.20


m 8.04
J200007 Ditto including hacking out existing and removing debris off site

Cement and sand (1:4) plastering with approved plasticiser


and waterproofing compound on concrete or brickwork walls,
columns, ceilings, beams, windows, sills, etc

J200008 13mm thick in one coat with steel trowelled finish


m2 16.10
J200009 20mm thick in two coats with steel trowelled finish m2 18.70
m2 0.97
J200010 Extra over above items (J200008) & (J200009) for laying in
patches, each patch not exceeding 1 m2

Rough cast cement and sand (1:4) plastering with approved


plasticiser on concrete or brick walls, columns, etc

J20001 1 20mm thick in two coats


m2 10.92
m2 0.60
J200012 Extra over plastering for laying in patches, each patch not
exceeding 1m2

Skim coat plastering on concrete or blockwalls, columns, etc

J 2 00 0 13 6 mm t hi ck m2 5.40

Granite aggregate plastering consisting of cement and


granite chippings (1:2) with approved plasticiser on concrete
or brick walls, columns, etc, including scrubbing to produce
exposed aggregate finish

J200014 20mm thick in two coats m2 22.38

BW-J2
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J200000 IN-SITU FINISHES (CONT'D)

Granite aggregate plastering consisting of cement and granite


chippings (1:2) with approved plasticiser on concrete or brick
walls, columns, etc, including scrubbing to produce exposed
aggregate finish (Cont'd)

J200015 25mm thick in two coats m2 24.12


J200016 m2 1.63
Extra over above items for laying in patches, each patch not
exceeding 1m2

Non-shrink cementitious plastering

J200017 20 mm thick to vertical faces of beams, walls, etc m2 45.90

J200018 Ditto to soffit of slab, beams, canopies, etc m2 58.50

Cementitious plastering on concrete or brick walls, columns,


ceilings, beams, windows, sills, etc

J200019 3mm thick in one coat with steel trowelled finish m2 8.32

J200020 10mm thick in two coats with steel trowelled finish m2 12.10
J200021 m2 21.17
20mm thick in three coats consisting 17mm cement and sand (1:3)
rendered backing in two coats and 3mm thick cementitious
plastering with steel trowelled finish

Vermiculite plaster on concrete or brick walls, columns,


ceilings, etc

J200022 13mm thick in sprayed finish m2 22.36

Hardwall plastering consisting of 9mm thick levelling course


and 3mm thick finishing coat of armourcoat plaster system
on concrete or brickwork walls (squash court front and sides
walls)

J200023 12mm thick in two coats with plastic trowelled finish m2 104.33

J300000 WALL TILING

Cement and sand (1:4) rendered backing on concrete or brick


walls, columns, etc to receive wall tiling, stone finishes, etc

J300001 13mm thick in one coat with wood floated finish m2 8.96

J300002 20mm thick in two coats with wood floated finish m2 9.50

BW-J3
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J300000 WALL TILING (CONT'D)


White glazed wall tiles complying with SS 301; bedding in
cement mortar (1:3) grouting, including angles, rounded
edges for forming pattern, etc laid and pointing neat with
white or tinted cement on rendered backing (screed
measured separately)

J300003 100 x 100 x 6mm thick white glazed wall tiles m2 33.60

J300004 100 x 100 x 6mm thick coloured glazed wall tiles m2 34.58

J300005 150mm x 150mm x 6mm thick coloured glazed wall tiling m2 54.00
J300006 m2 1.63
Extra over above items (J300003) to (J300005) for laying in
patches, each patch not exceeding 1 m2

J300007 m2 2.50
Extra over above items (J300003) to (J300005) for laying tiles with
compatible adhesive

J300008 Other sizes not specified above (any type and thickness) m2 40.71

Glazed ceramic wall tiles complying with SS 57; bedding in


cement mortar (1:3) grouting and pointing with white or tinted
cement on rendered backing (measured separately)

J300009 200 x 200 x 8mm thick glazed ceramic wall tiles m2 45.00
J300010 m2 1.70
Extra over above item for laying in patches, each patch not
exceeding 1m2

J30001 1 Extra over above itemfor laying tiles with compatible adhesive m2 2.50

J30001 2 Other sizes not specified above (any type and thickness) m2 49.00

Homogeneous stoneware porcelain wall tiles complying with


SS 57; bedding in cement mortar (1:3) grouting and pointing
with white or tinted cement on rendered backing (measured
separately)

J300013 m2 39.90
200 x 200 x 8mm thick matt homogeneous stoneware porcelain
wall tiles
J300014 m2 45.30
200 x 200 x 8mm thick polished homogeneou s stoneware
porcelain wall tiles
J300015 m2 45.30
300 x 300 x 8mm thick matt homogeneous stoneware porcelain
wall tiles

J300016 m2 69.70
300 x 300 x 8mm thick polished homogeneous stoneware
porcelain wall tiles

BW-J4
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J300000 WALL TILING (CONT'D)

Homogeneous stoneware porcelain wall tiles complying with


SS 57; bedding in cement mortar (1:3) grouting and pointing
with white or tinted cement on rendered backing (measured
separately) (Cont'd)

J300017 m2 1.70
Extra over above items for laying in patches, each patch not
exceeding 1m2

J30001 8 Other sizes not specified above (any type and thickness) m2 50.05

Mosaic tiles in sheet; bedding in cement mortar (1:3) grouting


and pointing with white or tinted cement on rendered backing
(screed measured separately)
J300019 m2 33.65
20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous unglazed
mosaic tiles with borders if directed
J300020 m2 34.42
20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous semi-glazed
mosaic tiles with borders if directed
J300021 m2 40.55
20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous glazed
mosaic tiles with borders if directed
J300023 m2 1.63
Extra over mosaic (any type) for laying in patches, each patch not
exceeding 1m2

J300024 Other sizes not specified above (any type and thickness) m2 41.57

Labour and cement mortars for laying of tiles (any type and
size) bedding in cement mortar (1:3); grouting and pointing
with white or tinted cement on rendered backing (measured
separately)

J300025 On wall surfaces m2 17.32


J300026 On wall surfaces with compatible tile adhesive m2 19.60

J300000 SUSPENDED CEILINGS

Heavy duty hot dipped galvanised steel exposed grid


suspension system comprising of 14mm wide galvanised steel
tees capped with precoated aluminium or steel strips
arranged in grid; suspended by 4mm diameter galvanised
steel rod hangers complete with adjustable clips, wall angles
and rivetting to all ends of grids along the boundary of ceiling

J600001 600 x 600 x 15mm thick prefinished face pattern panels mineral m2 23.80
fibre acoustic ceilings with narrow reveal edges in exposed grid
suspension system

BW-J5
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J600000 SUSPENDED CEILINGS (CONT'D)

Heavy duty hot dipped galvanised steel exposed grid


suspension system comprising of 14mm wide galvanised steel
tees capped with precoated aluminium or steel strips arranged
in grid; suspended by 4mm diameter galvanised steel rod
hangers complete with adjustable clips, wall angles and
rivetting to all ends of grids along the boundary of ceiling
(Cont'd)

J600002 600 x 600 x 20mm thick prefinished face pattern panels mineral m2 25.80
fibre acoustic ceilings with narrow reveal edges in exposed grid
suspension system

J600003 600 x 600 x 9mm thick fibrous plasterboard ceiling linings in m2 21.80
exposed grid suspension system

J600004 600 x 600 x 12mm thick fibrous plasterboard ceiling linings in m2 22.00
exposed grid suspension system

J600005 1200 x 600 x 9mm thick fibrous plasterboard ceiling linings in m2 21.40
exposed grid suspension system

J600006 1200 x 600 x 12mm thick fibrous plasterboard ceiling linings in m2 21.50
exposed grid suspension system

J600007 600 x 600 x 6mm thick calcium silicate board ceiling linings in m2 26.50
exposed grid suspension system

J600008 1200 x 600 x 6mm thick calcium silicate board ceiling linings in m2 26.00
exposed grid suspension system

Heavy duty hot dipped galvanised steel concealed suspension


system comprising of furring channels; suspended by
4mm diameter galvanised steel rod hangers complete with
adjustable clips, and rivetting to all ends of grids along the
boundary of ceiling

J600009 m2
9mm thick fibrous plasterboard ceiling linings in concealed 48.26
suspension system

J600010 9mm thick fibrous plasterboard drop ceiling linings not exceeding m 32.57
300mm girth in concealed suspension system
J600011 m2
12mm thick fibrous plasterboard ceiling linings in concealed 52.44
suspension system

J600012 12mm thick fibrous plasterboard drop ceiling linings not exceeding m 34.80
300mm girth in concealed suspension system
J600013 m2
6mm thick calcium silicate board ceiling linings in concealed 38.09
suspension system

BW-J6
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J600000 SUSPENDED CEILINGS (CONT'D)

Heavy duty hot dipped galvanised steel concealed suspension


system comprising of furring channels; suspended by
4mm diameter galvanised steel rod hangers complete with
adjustable clips, and rivetting to all ends of grids along the
boundary of ceiling (Cont'd)

J600014 6mm thick calcium silicate board drop ceiling linings not exceeding m 34.19
300mm girth in concealed suspension system
J600015 m2 38.28
9mm thick calcium silicate board ceiling linings in concealed
suspension system

J600016 9mm thick calcium silicate board drop ceiling linings not exceeding m 37.57
300mm girth in concealed suspension system
J600017 m2 49.27
12mm thick calcium silicate board ceiling linings in concealed
suspension system
J600018 m 37.48
12mm thick calcium silicate board drop ceiling linings not
exceeding 300mm girth in concealed suspension system

J600019 m2 25.00
600 x 600 x 6mm thick perforated ceiling linings in exposed grid
suspension system

J600020 m2 29.00
600 x 600 x 9mm thick perforated ceiling linings in exposed grid
suspension system
J600021 m2 33.00
600 x 600 x 12mm thick fibrous plasterboard ceiling linings in
exposed grid suspension system
J600022 m2 27.50
1200 x 600 x 6mm thick fibrous plasterboard ceiling linings in
exposed grid suspension system
J600023 m2 30.00
1200 x 600 x 9mm thick fibrous plasterboard ceiling linings in
exposed grid suspension system
J600024 m2 35.60
1200 x 600 x 12mm thick fibrous plasterboard ceiling linings in
exposed grid suspension system

Extra over ceiling linings for :

J600025 600 x 600mm access panels No 56.47

J600026 600 x 900mm access panels No 75.24

J600027 Downlight openings No 12.00

J600028 Air-conditioning diffuser openings No 23.94

BW-J7
J : WALL & CEILING FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

J600000 SUSPENDED CEILINGS (CONT'D)

Heavy duty hot dipped galvanised steel co ncealed


suspension system comprising of furring channels ;
suspended by 4mm diameter galvanised steel rod hangers
complete with adjustable clips, and rivetting to all ends of
grids along the boundary of ceiling (Cont'd)

Metal suspended ceiling system in polyester stoved


enamelled finish complete with modular carriers, hangers,
trims, adjustable clips and all necessary fixing accessories

J600023 600 x 600 x 0.70mm thick perforated lay-in aluminium tiles with m2 69.00
and including non-woven acoustic inlay

J600024 0.60mm thick linear perforated metal ceiling in 100mm or 200mm m2 71.20
module with and including 0.20mm thick black acoustic felt inlay

J700000 ALUMINIUM CEILING

J700001 Aluminium ceiling comprising of baked enamel coating aluminium m2 70.30


panels, aluminium carrier, black infill and all necessary fixing
accessories

J700002 Replace defective aluminium baked enamel coating panels m 4.40

J800000 SUNDRIES

J800001 Aluminium exposed grid suspension system comprising of main and m2 12.50
secondary tees arranged in grid; suspended by 4mm diameter
galvanised steel rod hangers complete with adjustable clips, wall
angles and rivetting to all ends of grids along the boundary of
ceiling

J800002 Aluminum concealed grid suspension system comprising of main m2 14.30


and secondary tees arranged in grid; suspended by 4mm diameter
galvanised steel rod hangers complete with adjustable clips, wall
angles and rivetting to all ends of grids along the boundary of
ceiling

J800003 Shackle clip and rawl bolt with ring for hanging adjustable rod m2 2.10
hanger to soffit of ceiling

J800004 Approved T-bars for strengthening ceiling board linings m 1.14

J800005 Silver finished reflective egg crate diffuser m2 88.27

J800006 White acrylic egg crate diffuser m2 30.78

BW-J8
SECTION K: FLOOR FINISHINGS
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K100000 DEMOLITION / ALTERATIONS

Removing existing floor finishes of any thickness in whole or


in patch including removing debris off site and preparing
surfaces to receive new

K100001 Taking out damaged pointing and repointing in ordinary Portland m2 3.48
cement, white or coloured cement to joints of existing floor tilings,
stone finishings, etc.

K1 00002 Cutting out cracks in any type of pavings to a width of at least m 3.84
15mm, form undercut edges, removing debris off site and
including making good with materials to match existing

Extra labour and materials for floor and wall finishings (any type
and thickness) for working into recess, groove

K100003 Not exceeding 75mm girth (For girth exceeding 300mm measured m 1.62
separately)

K100004 Working around sanitary fittings, ventilators, fixture etc. (measured m 4.86
only in patch work)

K100005 Hacking existing concrete surfaces to form keys, washing and m2 1.60
cleaning to receive finishings

K1 00006 Preparing existing floor surfaces by patching up small holes, minor m2 3.13
cracks, etc. and washing down to receive floor coating

K100007 Cutting damaged joint, hot weld with matching w elding rod, m 7.78
polishing and wax jointing area to match existing for vinyl floor tiles
or sheets (any type)

K100008 Labour, equipment to shampoo and clean existing carpet m2 3.02

Removing existing floor finishes of any thickness in whole or


in patch including removing debris off site and preparing
surfaces to receive new

K1 00009 Removing existing division strips (any type) and making good work m 1.19
disturbed (For replacement of dividing strip only)

K100010 Hacking existing screed, subsequently lay new average 50mm m2 48.60
thick granolithic paving including application of bonding agent and
saw cut into panels

K100011 Lay average 5mm thick epoxy mortar on the new screed in m2 75.60
accordance with the performance specification (screed to be cured
at least 7 days) including provision of crack inducing joints with
sealants

BW-K1
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K200000 IN-SITU FINISHES

Cement and sand (1:3) paving with steel trowelled finish on


concrete floors including forming angles, rounded edge, etc.

K200001 Average 20mm thick laid flat or to falls m2 7.68

K200002 Average 25mm thick laid flat or to falls m2 8.28

K200003 Average 32mm thick laid flat or to falls m2 9.24

K200004 Average 35mm thick laid flat or to falls m2 -

K200005 Average 38mm thick laid flat or to falls m2 9.72

K200006 Average 50mm thick laid flat or to falls m2 11.28


K200007 m2 0.36
Extra over above items for laying in patches, each patch not
exceeding 1m2
K200008 m2 0.36
Extra over above item for lining out paving in squares or
rectangles not exceeding 0.40m2
K200009 m 11.64
20mm thick to plinths, skirtings, risers, kerbs, and returns, etc. with
all necessary top splayed or rounded and bottom coved not
exceeding 300mm high

Cement and sand (1:3) paving mixed with waterproofing


compound; steel trowelled finish on concrete floors including
forming angles, rounded edge, etc.

K20001 0 Average 25mm thick laid flat or to falls m2 11.77

K20001 1 Average 35mm thick laid flat or to falls m2 14.36

K200012 Average 50mm thick laid flat or to falls m2 17.50


K200013 m2 0.65
Extra over above items for laying in patches, each patch not
exceeding 1m2
K200014 m2 0.65
Extra over above item for lining out paving in squares or rectangles
not exceeding 0.40m2
K200015 m 5.29
20mm thick to plinths, skirtings, risers, kerbs, and returns, etc. with
all necessary top splayed or rounded and bottom coved not
exceeding 300mm high

Cement and sand (1:3) paving mixed with integral floor


hardener additive at the rate of 3kg/m2; steel trowelled finish
on concrete floors

K200016 25mm thick m2 15.01

BW-K2
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K200000 IN-SITU FINISHES (CONT'D)

Cement and sand (1:3) paving mixed with integral floor


hardener additive at the rate of 3kg/m2; steel trowelled finish
on concrete floors (Cont'd)

K200017 50mm thick m2 16.41


K200018 m2 0.65
Extra over above items for laying in patches, each patch not
exceeding 1m2
K200019 m2 0.65
Extra over above item for lining out paving in squares or
rectangles not exceeding 0.40m2

Coloured cement and sand (1:3) topping with steel trowelled


finish on concrete floors including forming angles, rounded
edge, etc.

K200020 Average 13mm thick green coloured topping laid flat to falls m2 13.20

K200021 Average 13mm thick red coloured topping laid flat to falls m2 11.18
K200022 m2 0.43
Extra over above items for laying in patches each patch not
exceeding 1m2
K200023 m2 0.43
Extra over above items for lining out paving in squares or
rectangles not exceeding 0.40m2
K200024 m 16.92
13mm thick green coloured paving to plinths, skirtings, risers,
kerbs and returns with all necessary top splayed or rounded and
bottom coved not exceeding 300mm high
K200025 m 14.40
13mm thick red coloured paving to plinths, skirtings, risers, kerbs
and returns with all necessary top splayed or rounded and bottom
coved not exceeding 300mm high

Non-shrink cemetitous screed

K200026 Average 20 mm thick to floor including trowelling smooth m2 44.76

K200027 Add or deduct to/from above item for every consecutive layer of m2 11.28
5mm thick

Plain granolithic paving consisting of cement, sand and


granite chippings (2:1:5) with steel trowelled finish and
including angles, coves, etc.

K200028 Average 25mm thick topping laid flat or to falls m2 20.84

K200029 Average 32mm thick topping laid flat or to falls m2 21.80

BW-K3
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K200000 IN-SITU FINISHES (CONT'D)

Plain granolithic paving consisting of cement, sand and


granite chippings (2:1:5) with steel trowelled finish and
including angles, coves, etc. (Cont'd)

K200031 Extra over above items (K200028) to (K2 00030) for laying in m2 0.36
patches, each patch not exceeding 1 m2

K200032 Extra over above items (K200028) to (K200030) for lining out m2 0.36
paving in squares or rectangles not exceeding 0.40m2

K200033 Extra over above items (K200028) to (K200030) for exposed m2 3.24
aggregate granolithic finishing

K200034 20mm thick to plinths, skirtings, risers, kerbs, and returns, etc. with m 8.93
all necessary top splayed or rounded and bottom coved not
exceeding 300mm high

Granolithic exposed aggregate paving consisting of cement,


sand and granite chippings of 5mm gauge (1:2:5) set out in
panels with 15mm wide x 15mm deep recessed joints
laterally at approximately 1.20m centres including
scrubbing to produce exposed aggregate finish

K200035 Average 25mm thick toppings laid flat or to falls


m2 24.52
K200036 Average 32mm thick topping laid flat or to falls m2 25.38

K200037 Average 50mm thick toppings laid flat or to falls m2 26.78


m2 0.36
K200038 Extra over above items for laying in patches, each patch not
exceeding 1m2
m2 0.36
K200039 Extra over above items for lining out paving in squares or
rectangles not exceeding 0.40m2

Pebble wash paving consisting of 3 - 5mm graded natural


wash pebbles with cement and sand (1:3) on concrete floors
with steel trowelled and wood floated finish

K200040 50mm thick


m2 70.20
m2 74.50
K200041 Supply and lay 25mm thick pebble wash finish (pebble size 3mm
to 5mm) to floor, laid in section, providing all necessary copper or
Aluminium dividing strips.

K200042 Supply and lay 300mm x 300mm x 50mm thick pebble wash finish m2 75.60
slab

K200043 Supply and lay footpath side border 100 mm to 150mm girth with m 14.40
pebble wash finish (pebble size 3mm to 5mm) of 25mm thick
including all necessary copper or Aluminuim divding strips.

BW-K4
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K200000 IN-SITU FINISHES (CONT'D)

Pebble wash paving consisting of 3 - 5mm graded natural


wash pebbles with cement and sand (1:3) on concrete floors
with steel trowelled and wood floated finish (Cont'd)

K200044 Supply and lay border 100 mm to 150mm girth with pebble m 7.30
wash/colour grandolithic finish of 15mm thick

K200046 Supply and lay border 100 mm to 150mm girth with pebble m 12.30
wash/colour grandolithic finish of 15mm thick

K200045 Supply and lay footpath side border 150mm to 300mm girth with m 25.00
pebble wash finish (pebble size 3mm to 5mm) of 25mm thick
including all necessary copper or Aluminuim divding strips.

K300000 FLOOR TILING

Cement and sand (1:3) screed backing on concrete floors laid


flat or to falls to receive floor tiling, stone finishes, etc

K300001 Average 20mm thick


m2 7.44
K300002 Average 25mm thick m2 7.98

K300003 Average 35mm thick m2 8.74


K300004 Average 50mm thick m2 11.51

m2 0.38
K300005 Extra over above items for laying in patches, each patch not
exceeding 1m2

Ceramic floor tiles complying with SS 57; bedding in cement


mortar (1:3) grouting and pointing with white or tinted cement
on screed backing (measured separately)

K300006 200 x 200 x 8mm thick glazed ceramic floor tiles


m2 43.96
m2 1.62
K300007 Extra over above item for laying in patches, each patch not
exceeding 1m2

K300008 200 x 200 x 8mm thick glazed ceramic tiles to skirtings, plinths, m 9.29
risers, kerbs and returns, etc. including angles, rounded edge etc.
not exceeding 300mm high

K300009 Extra over flooring for 150 x 75 x 8.5mm thick fully vitreous m 6.05
bullnosed non-slip tiles

K3000010 300 x 300 x 8mm thick glazed ceramic floor tiles m2 46.87

K300001 1 Extra over above item for laying in patches, each patch not m2 1.62
exceeding 1m2

BW-K5
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K300000 FLOOR TILING (CONT'D)

Ceramic floor tiles complying with SS 57; bedding in cement


mortar (1:3) grouting and pointing with white or tinted cement
on screed backing (measured separately) (Cont'd)

K3000012 300 x 300 x 8mm thick glazed ceramic tiles to skirtings, plinths, m 9.83
risers, kerbs and returns, etc. including angles, rounded edge etc.
not exceeding 300mm high

K3000013 Extra over flooring for 150 x 75 x 8.5mm thick fully vitreous m 6.05
bullnosed non-slip tiles

Homogeneous stoneware porcelain floor tiles complying with


SS 57; bedding in cement mortar (1:3) grouting and pointing
with white or tinted cement on screed backing (measured
separately)

K3000014 200 x 200 x 8mm thick matt homogeneous stoneware porcelain m2 38.45
floor tiles

K3000015 Extra over above item for laying in patches, each patch not m2 1.62
exceeding 1m2

m 8.10
K300016 200 x 200 x 8mm thick matt homogeneous stoneware porcelain
floor tiles to skirtings, plinths, risers, kerbs and returns, etc.
including angles, rounded edge etc. not exceeding 300mm high

K300017 Extra over flooring for 150 x 75 x 8.5mm thick fully vitreous m 6.05
bullnosed non-slip tiles

K300018 200 x 200 x 8mm thick polished homogeneous stoneware m2 43.52


porcelain floor tiles

K300019 Extra over above item for laying in patches, each patch not m2 1.62
exceeding 1m2

m 9.18
K300020 200 x 200 x 8mm thick polished homogeneous stoneware
porcelain floor tiles to skirtings, plinths, risers, kerbs and returns,
etc. including angles, rounded edge etc, not exceeding 300mm
high.

K300021 Extra over flooring for 150 x 75 x 8.5mm thick full y vitreous m 6.05
bullnosed non-slip tiles

K300022 300 x 300 x 8mm thick matt homogeneous stoneware porcelain m2 43.63
floor tiles

K300023 Extra over above item for laying in patches, each patch not m2 1.62
exceeding 1m2

BW-K6
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K300000 FLOOR TILING (CONT'D)

Homogeneous stoneware porcelain floor tiles complying with


SS 57; bedding in cement mortar (1:3) grouting and pointing
with white or tinted cement on screed backing (measured
separately) (Cont'd)

K300024 300 x 300 x 8mm thick matt homogeneous stoneware porcelain m 9.29
floor tiles to skirtings, plinths, risers, kerbs and returns, etc.
including angles, rounded edge etc, not exceeding 300mm high

K300025 Extra over flooring for 150 x 75 x 8.5mm thick fully vitreous m 6.05
bullnosed non-slip tiles

K300026 300 x 300 x 8mm thick polished homogeneous s toneware m2 67.18


porcelain floor tiles

K300027 Extra over above item for laying in patches, each patch not m2 1.62
exceeding 1m2

K300028 300 x 300 x 8mm thick polished homogeneous stoneware m 14.15


porcelain floor tiles to skirtings, plinths, risers, kerbs and returns,
etc. including angles, rounded edge etc, not exceeding 300mm
high

K300029 Extra over flooring for 150 x 75 x 8.5mm thick fully vitreous m 6.05
bullnosed non-slip tiles

Quarry floor tiles bedding in cement mortar (1:3) grouting and


pointing with white or tinted cement on screed backing
(measured separately)

K300030 200 x 200 x 8mm thick quarry floor tiles


m2 34.78
m2 1.62
K300031 Extra over above item for laying in patches, each patch not
exceeding 1m2

K300032 200 x 200 x 8mm quarry floor tiles to skirtings, plinths, risers, m 7.34
kerbs and returns, etc. including angles, rounded edge etc, not
exceeding 300mm high

Mosaic tiles in sheet; bedding in cement mortar (1:3) grouting


and pointing with white or tinted cement on screed backing
(measured separately)

K300033 20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous unglazed m2 34.58


mosaic floor tiles with borders if directed

K300034 Extra over above item for laying in patches, each patch not m2 1.32
exceeding 1m2

BW-K7
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K300000 FLOOR TILING (CONT'D)

Mosaic tiles in sheet; bedding in cement mortar (1:3) grouting


and pointing with white or tinted cement on screed backing
(measured separately) (Cont'd)

K300035 20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous unglazed m 7.78


mosaic floor tiles to skirtings, plinths, risers, kerbs and returns, etc.
including angles, rounded edge etc, not exceeding 300mm high

K300036 20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous semi-glazed m2 43.10


mosaic floor tiles with borders if directed

K300037 Extra over above item (L200036) for laying in patches, each patch m2 2.05
not exceeding 1m2

K300038 20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous semi-glazed m 8.75


mosaic floor tiles to skirtings, plinths, risers, kerbs and returns, etc.
including angles, rounded edge etc, not exceeding 300mm high

K300039 20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitr eous glazed m2 36.48


mosaic floor tiles with borders if directed

K300040 Extra over above item for laying in patches, each patch not m2 1.32
exceeding 1m2

K300041 20 x 20 x 4.5mm thick or 25 x 25 x 5mm thick vitreous glazed m 9.94


mosaic floor tiles to skirtings, plinths, risers, kerbs and returns, etc.
including angles, rounded edge etc, not exceeding 300mm high

K300042 Extra over mosaic for 150 x 75 x 8.5mm thick fully vitreous m 6.05
bullnosed non-slip tiles

Labour and cement mortars for laying of tiles (tiles provided


by users; any type and size) bedding in cement mortar (1:3);
grouting and pointing with white or tinted cement on
rendered backing (measured separately)

K300043 On floors, treads, etc


m2 15.96
m 3.46
K300044 On skirtings, plinths, risers, kerbs and returns, etc. including
angles, rounded edge etc, not exceeding 300mm high

K300045 On floors, treads, etc with compatible tile adhesive m2 15.12

m 3.89
K300046 On skirtings, plinths, risers, kerbs and returns, etc. including
angles, rounded edge etc. with compatible tile adhesive not
exceeding 300mm high

K300047 Other sizes of tiles (any type and thickness) not mentioned above m2 53.50

BW-K8
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K400000 RESILIENT FINISHES

Heavy duty homogeneous vinyl sheeting laid with approved


adhesive with hot welding seam joints and matching welding
chord on prepared floor surfaces

K400001 2mm thick m2 50.98

K400002 3mm thick m2 51.62


K400003 m2 0.43
Extra over above items for laying in patches, each patch not
exceeding 1m2

Resilient sheet acoustic vinyl sheeting laid with approved


adhesive with hot welding seam joints and matching welding
chord on prepared floor surfaces

K400004 2mm thick m2 55.94

K400005 3mm thick m2 56.92


K400006 m2 0.43
Extra over above items for laying in patches, each patch not
exceeding 1m2

Sport vinyl sheeting laid with approved adhesive with hot


welding seam joints and matching welding chord on prepared
floor surfaces

K400007 5.50mm thick m2 99.36


K400008 m2 0.43
Extra over above item for laying in patches, each patch not
exceeding 1m2

Vinyl sports flooring inclusive of pvc foam backing on


prepared floor surfaces

K400009 6mm m2 100.00

K400010 8mm m2 115.00

K400011 11mm m2 130.00

K400012 13mm m2 145.00

PVC vinyl tiles (any size) laid with approved adhesive on


prepared floor surfaces

K4000013 2mm thick m2 34.13

K400014 3mm thick m2 43.09


exceeding
K400015
Extra over above items for laying in patches, each patch not 1m2
BW-K9
K: FLOOR FINISHINGS
m2 0.43

BW-
K10
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K400000 RESILIENT FINISHES (CONT'D)

Vinyl skirtings
K400016 m 19.87
Extend vinyl sheet and cove up to 100mm high complete with cove
former and cappings

K400017 100mm PVC sit-on skirtings m 8.75

Labour and compatible adhesive for laying of vinyl finishes


(any type and size) on prepared floor surfaces including hot
welding seam joints with matching welding chords

K400018 Vinyl tiles m2 7.10

K400019 Vinyl sheeting m2 13.30

Self levelling compound on top of cement and sand (1:3)


screed to receive vinyl tiles or sheeting

K400020 3mm to 5mm thick m2 16.10

Carpet tiles (100% dupont 6,6 nylon, graphic loop, solution-


dyed, pile weight 680 g/m2) (any size) laid with approved
adhesive on prepared floor surfaces

K400021 7mm thick m2 45.68


K400022 m2 0.43
Extra over above item for laying in patches, each patch not
exceeding 1m2

Broadloom carpet laid with approved adhesive on prepared


floor surfaces complete with foam rubber underlay and any
necessary carpet accessories

K400025 80% wool, 20% nylon, Axminister woven, pile weight 1200g/m2; m2 90.72
31.5dm x 27.6dm density, custom design and colours
K400026 m2 37.37
100% , solution dyed nylon; loop graphic; pile weight 28 oz/square
yd with woven polypropylene backing

Labour and compatible adhesive for laying carpet on


prepared floor surfaces

K400027 Carpet tiles m2 8.60

K400028 Broadloom carpets m2 9.60

BW-K10
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K400000
RESILIENT FINISHES (CONT'D)

Cast in-situ rubberised safety flooring comprising of 10mm


thick coloured ethylene propylene diene-poly nethylene
(EPDM) rubber granules top layer and 40mm thick black
shredded rubber bottom layer on concrete floors
50mm thick 98.17
K400029 m2

K500000 DUST-PROOF COATINGS

K500001 Preparing and applying three coats of dust-proof coatings on m2 2.37


concrete floors

K600000 WATERPROOFING MEMBRANE

K600001 1.50mm thick liquid applied two component cementitious m2 13.93


waterproofing membrane on concrete floors

K700000 EPOXY COATING

K700001 Preparing and applying one coat of primer and one finishing coat m2 11.23
of solvent-free 2 component epoxy resin coating on concrete floors

K800000 DIVISION STRIPS


Division strips set into different floor finishes

K800001 25mm wide x 3mm thick aluminium division strips m 6.45


K800002 38mm wide x 3mm thick aluminium division strips m 8.16

K900000 SUNDRIES

K900001 m2 29.70
Waterproofing coating system to properly prepared concrete floor
surface including forming up skirtings, plugging to wall and floor
joints, working in and around floor traps, joints between pipe lead-
ins and floor, etc. and including five (5) years manufacturer's
guarantee

year manufacturer's
K900002 warranty
Anti-slip system to exposed tiles or concrete surfaces in
accordance with the manufacturer's instructions including one (1)

BW-K11
K: FLOOR FINISHINGS
m2 36.61

K900003 Cove-former for vinyl floor tiles or sheets (any type) m 5.16

BW-K12
K: FLOOR FINISHINGS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

K900000 SUNDRIES (CONT'D)

K900004 PVC capping strip to the edge of skirting ditto (any type) m 3.58

K900005 PVC nosing to steps, doorways, etc. m 4.92

K900006 Aluminium nosing to steps, doorways, etc. m 10.32


K900007 m 4.80
25mm to 50mm wide x 1 .7m thick non-skid fixed vinyl profile strip
fixed with adhesive to threshold, treads, etc.

K900008 Labour and chemical to buff finished floor of vinyl sheet m2 3.73
K900009
Aluminium naplocks nailed to concrete floor to receive edge of
vinyl flooring

K900010 Single-sided naplocks m 10.26


K90001 1 m 14.36
Double-sided, to receive edge of vinyl flooring and the other side
to receive other floor finishing

K900012 100% natural rubber underlay (1 ,630gm/m2 weight) m2 4.00

BW-K13
SECTION L: PLUMBING
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING

Medium grade coated cast iron soil, waste, ventilating and


anti-syphonage pipes complying with SS 33 including spigot
and socket joints (in replacement including making good
works disturbed)

L100001 No 30.24
50 x 50mm equal and unequal tees with cleaning eye including
extra joints
L100002 No 29.61
50 x 50mm equal and unequal tees without cleaning eye including
extra joints

L1 00003 75mm diameter bends with cleaning eye including extra joints No 26.04

L1 00004 75mm diameter bends without cleaning eye including extra joints No 25.60
L100005 No 24.15
75mm diameter swanneck bends without cleaning eye including
extra joints
L100006 No 36.75
75mm equal and unequal junctions, etc without cleaning eye
including extra joints

L1 00007 75 x 75mm tees with cleaning eye including extra joints No 35.81

L100008 75 x 75mm tees without cleaning eye including extra joints No 35.18

L1 00009 100mm diameter bends with cleaning eye including extra joints No 32.87
L1 00010 100mm diameter bends without cleaning eye including extra joints No 28.25

L1 00011 75 x 50mm reducers including extra joints No 22.05

L1 00012 100 x 75mm reducers including extra joints No 26.88


L100013 100mm diameter swanneck bends, shoes, 100 to 75mm diameter No 30.24
reducer, etc. with or without cleaning eye including extra joints

L100014 100mm diameter equal and unequal junctions, etc, with or without No 47.57
cleaning eye including extra joints
L100015 No 42.74
100 x 100mm diameter tees with cleaning eye including extra
joints
L100016 No 42.74
100 x 100mm diameter tees without cleaning eye including extra
joints

L1 00017 150mm diameter bends with cleaning eye including extra joints No 52.40

L1 00018 150mm diameter bends without cleaning eye including extra joints No 50.93

BW-L1
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Medium grade coated cast iron soil, waste, ventilating and


anti-syphonage pipes complying with SS 33 including spigot
and socket joints (in replacement including making good
works disturbed) (Cont'd)

L100019 150mm diameter swanneck bends without cleaning eye including No 51.80
extra joints

L100020 150mm diameter equal and unequal junctions, etc, without No 86.21
cleaning eye including extra joints

L1 00021 150 x 75mm reducers without cleaning eye including extra joints No 39.27

No 84.21
L100022 150 x 150mm diameter tees with cleaning eye including extra
joints

L100023 150 x 150mm diameter tees without cleaning eye including extra No 73.71
joints

Galvanised iron ballon gratings fixed on top of pipes of any


types including painting

L100024 100mm
No 5.15
No 9.20
L100025 150mm

Floor traps

Coated cast iron floor traps 'P' or 'S' type with 75mm deep
seals, 150mm diameter raising piece, 75mm diameter outgo
and necessary side inlets, galvanised or UPV C hinged
gratings and frames and jointed in caulked lead including all
connections, cutting or coring through concrete floors

L1 00025 Setting in suspended slabs including all necessary formwork


No 131.54
No 127.01
L100026 Setting traps in floors and packing around with concrete (grade 15)
including all necessary excavation, disposal and formwork

L100027 Setting in suspended slabs including all necessary formwork No 113.85

No 107.16
L100028 Setting traps in floors and packing around with concrete (grade 15)
including all necessary excavation, disposal and formwork

L100029 100 mm diameter UPVC trap with riser and UPVC grating No 60.69
including all connection, excavation, formwork, cutting or coring
through concrete floor (if in existing building) packing around trap
with concrete (Grade 15) and making good surrounds

BW-L2
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Floor traps (Cont'd)

Unplasticised polyvinyl chloride floor traps 'P' or 'S' type with


75mm deep seals, 150mm diameter raising piece, 75mm or
100mm diameter outgo and necessary side inlets, uPVC
hinged gratings including all connections, cutting or coring
through concrete floors

L100030 Add to above items (d) for setting in suspended floor slab No 9.35

Floor trap gratings including making good work disturbed


and taking out existing
L100031 No 4.31
150mm square or circular UPVC floor trap gratings and frames
embedded in concrete

L100032 75mm diameter loose UPVC floor trap gratings No 3.05

L100033 150mm diameter loose UPVC floor trap gratings No 3.36

Water service pipework

Medium duty galvanised steel pipes complying with SS 17


with approved internal linings including screw joints (for
repairs works only)

L1 00034 13mm diameter elbows No 1.47

L100035 15mm diameter bends/elbows No 2.52

L100036 20mm diameter bends/elbows No 3.63

L100037 25mm diameter bends/elbows No 4.43

L100038 32mm diameter bends/elbows No 5.90

L100039 40mm diameter bends/elbows No 7.13

L100040 50mm diameter bends/elbows No 8.42

L100041 13mm diameter tees No 2.52

L100042 15 x 15 x 15mm diameter tees No 3.40

L100043 20 x 20 x 20mm diameter tees No 5.10

L1 00044 25 x 25 x 25mm diameter tees No 6.35

L1 00045 32 x 32 x 32mm diameter tees No 8.96

BW-L3
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Medium duty galvanised steel pipes complying with SS 17


with approved internal linings including screw joints (for
repairs works only) (Cont'd)

L1 00046 40 x 40 x 40mm diameter tees No 10.32

L1 00047 50 x 50 x 50mm diameter tees No 13.04

L100048 65mm diameter tees No 21.20

L1 00049 75mm diameter tees No 28.30

L100050 13mm diameter sockets No 1.40

L100051 15mm diameter sockets No 1.93

L100052 25mm diameter sockets No 4.42

L100053 40mm diameter sockets No 6.57

L100054 50mm diameter sockets No 8.50

L100055 65mm diameter sockets No 15.99

L100056 75mm diameter sockets No 16.66

L100057 80mm diameter sockets No 19.51

L1 00058 13mm diameter nipples No 1.58

L100059 15mm diameter nipples No 2.15

L100060 20mm diameter nipples No 3.63

L100061 25mm diameter nipples No 3.99

L100062 32mm diameter nipples No 5.90

L100063 40mm diameter nipples No 6.46

L100064 50mm diameter nipples No 8.39

L100065 65mm diameter nipples No 14.97

L100066 75mm diameter nipples No 15.70

L100067 80mm diameter nipples No 22.11

BW-L4
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Medium duty galvanised steel pipes complying with SS 17


with approved internal linings including screw joints (for
repairs works only) (Cont'd)

L100068 50 x 15mm diameter reducing bends/elbows No 13.27

L100069 50 x 40mm diameter reducing bends/elbows No 13.84

L100070 65 x 15mm diameter reducing bends/elbows No 24.38

L100071 65 x 50mm diameter reducing bends/elbows No 24.78

L100072 75 x 32mm diameter reducing tees No 37.49

L100073 25 x 13mm diameter reducing sockets No 8.40

L100074 25 x 15mm diameter reducing sockets No 9.35

L100075 50 x 25mm diameter reducing sockets No 12.70

L100076 50 x 40mm diameter reducing sockets No 16.22

L100077 65 x 50mm diameter reducing sockets No 19.39

Compression fittings complying with BS 864 Part 2 (for repair


works only)

L1 00078 15mm diameter bends/elbows No 11.34

L100079 22mm diameter bends/elbows No 13.61

L100080 28mm diameter bends/elbows No 17.01

L100081 35mm diameter bends/elbows No 22.68

L100082 42mm diameter bends/elbows No 28.35

L100083 54mm diameter bends/elbows No 39.69

L100084 15 x 15 x 15mm diameter tees No 6.35

L1 00085 22 x 22 x 22mm diameter tees No 7.71

L1 00086 25 x 25 x 25mm diameter tees No 12.70

L100087 28 x 28 x 28mm diameter tees No 14.06

L1 00088 35 x 35 x 35mm diameter tees No 23.02

BW-L5
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Compression fittings complying with BS 864 Part 2 (for repair


works only) (Cont'd)

L1 00089 42 x 42 x 42mm diameter tees No 28.01

L1 00090 54 x 54 x 54mm diameter tees No 46.49

L100091 75mm diameter tees No 153.62

L100092 75 x 75 x 50mm dimeter reducing tees No 143.12

L100093 76 x 76 x 50mm diameter reducing tees No 96.84

L100094 15mm diameter couplings No 4.88

L100095 22mm diameter couplings No 6.92

L100096 25mm diameter couplings No 9.41

L100097 28mm diameter couplings No 10.77

L100098 35mm diameter couplings No 14.06

L100099 42mm diameter couplings No 19.39

L100100 54mm diameter couplings No 26.20

Copper pipe holderbats


L100101 No 3.29
Taking out existing copper pipe holderbats (any diameter) and
replacing with new including making good works disturbed)

Copper Pipe complying with BS 2871 including compression


joints to BS 864 Part 2 B242 (Repair works) (including cutting,
adjustment to pipes and fittings, removal off site and make
good works disturbed)
L1 00102 15mm dia. Copper fitting elbow, reducing elbow or flanged elbow no 4.20

L1 00103 20mm dia. Copper fitting elbow, reducing elbow or flanged elbow no 6.30

L1 00104 25mm dia. Copper fitting elbow, reducing elbow or flanged elbow no 8.40

L1 00105 32mm dia. Copper fitting elbow, reducing elbow or flanged elbow no 12.08

BW-L6
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Copper Pipe complying with BS 2871 including compression


joints to BS 864 Part 2 B242 (Repair works) (including cutting,
adjustment to pipes and fittings, removal off site and make
good works disturbed) (Cont'd)
40mm dia. Copper fitting elbow, reducing elbow or flanged elbow
L1 00106 no 16.80

L1 00107 50mm dia. Copper fitting elbow, reducing elbow or flanged elbow no 28.35

L1 00108 67mm dia. Copper fitting elbow, reducing elbow or flanged elbow no 42.00

L1 00109 20mm dia copper fitting reducer to the next smaller diameter no 4.73

L1 00110 25mm dia copper fitting reducer to the next smaller diameter no 8.40

L1 00111 32mm dia copper fitting reducer to the next smaller diameter no 11.55

L1 00112 40mm dia copper fitting reducer to the next smaller diameter no 15.75

L100113 50mm dia copper fitting reducer to the next smaller diameter no 23.10

L100114 67mm dia copper fitting reducer to the next smaller diameter no 27.30

L1 00115 76mm dia copper fitting reducer to the next smaller diameter no 29.40

L1001 16 15mm dia copper fitting equal tee no 3.68

L1001 17 20mm dia copper fitting equal tee no 6.30

L1001 18 25mm dia copper fitting equal tee no 10.50

L1001 19 32mm dia copper fitting equal tee no 13.65

L100120 40mm dia copper fitting equal tee no 19.95

L100121 50mm dia copper fitting equal tee no 28.35

L100122 20mm dia copper fitting unequal tee no 6.30

L100123 25mm dia copper fitting unequal tee no 7.35

L100124 32mm dia copper fitting unequal tee no 13.65

L100125 40mm dia copper fitting unequal tee no 14.33

L100126 50mm dia copper fitting unequal tee no 15.05

BW-L7
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Copper Pipe complying with BS 2871 including compression


joints to BS 864 Part 2 B242 (Repair works) (including cutting,
adjustment to pipes and fittings, removal off site and make
good works disturbed) (Cont'd)

L100127 15mm dia. Copper fitting coupling no 3.68

L100128 20mm dia. Copper fitting coupling no 4.20

L100129 25mm dia. Copper fitting coupling no 8.40

L100130 32mm dia. Copper fitting coupling no 11.03

L100131 40mm dia. Copper fitting coupling no 12.60

L100132 50mm dia. Copper fitting coupling no 13.65

L100133 15mm dia. Copper fitting union or connector no 4.20

L100134 25mm dia. Copper fitting union or connector no 5.78

L100135 32mm dia. Copper fitting union or connector no 7.35

L100136 40mm dia. Copper fitting union or connecto no 8.93

L100137 50mm dia. Copper fitting union or connector no 12.18

Unplasticised polyvinyl chloride pipe complying with SS 141


including solvent cement joints (for repair works only)

L100138 13mm diameter bends/elbows No 5.56

L100139 20mm diameter bends/elbows No 5.95

L100140 25mm diameter bends/elbows No 6.52

L100141 32mm diameter bends/elbows No 7.37

L100142 40mm diameter bends/elbows No 8.96

L100143 50mm diameter bends/elbows No 11.51

L100144 65mm diameter bends/elbows No 12.43

L100145 75mm dIameter bends/elbows No 13.43

L100146 100mm diameter bends/elbows No 17.80

L100147 13 x 13 x 13mm diameter tees No 6.69

BW-L8
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Unplasticised polyvinyl chloride pipe complying with SS 141


including solvent cement joints (for repair works only)
(Cont'd)

L100148 20 x 20 x 20mm diameter tees No 6.97

L100149 25 x 25 x 25mm diameter tees No 7.82

L1 00150 32 x 32 x 32mm diameter tees No 9.53

L100151 40 x 40 x 40mm diameter tees No 11.23

L100152 50 x 50 x 50mm diameter tees No 15.59

L100153 65mm diameter tee No 26.89

L100154 75mm diameter tee No 18.25

L100155 100mm diameter tee No 37.43

L100156 20 x 13mm diameter reducers No 4.25

L100157 25 x 13mm diameter reducers No 4.82

L100158 25 x 20mm diameter reducers No 4.82

L100159 32 x 25mm diameter reducers No 5.27

L100160 40 x 32mm diameter reducers No 9.53

L100161 50 x 40mm diameter reducers No 15.59

L100162 65 x 50mm diameter reducers No 16.17

L100163 80 x 50mm diameter reducers No 17.18

L100164 100 x 80mm diameter reducers No 27.72

L100165 20 x 13 x 20mm diameter reducing tees No 8.22

L100166 25 x 13 x 25mm diameter reducing tees No 8.79

L100167 25 x 20 x 25mm diameter reducing tees No 8.79

L100168 32 x 13 x 32mm diameter reducing tees No 8.96

L100169 32 x 20 x 32mm diameter reducing tees No 8.96

L100170 32 x 25 x 32mm diameter reducing tees No 8.96

BW-L9
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Unplasticised polyvinyl chloride pipe complying with SS 141


including solvent cement joints (for repair works only)
(Cont'd)

L1 00171 40 x 13 x 40mm diameter reducing tees No 11.90

L1 00172 40 x 20 x 40mm diameter reducing tees No 11.90

L1 00173 40 x 25 x 40mm diameter reducing tees No 11.90

L1 00174 40 x 32 x 40mm diameter reducing tees No 11.90

L100175 50 x 13 x 50mm diameter reducing tees No 14.46

L100176 50 x 20 x 50mm diameter reducing tees No 14.46

L100177 50 x 25 x 50mm diameter reducing tees No 14.46

L100178 50 x 32 x 50mm diameter reducing tees No 14.46

L100179 50 x 40 x 50mm diameter reducing tees No 14.46

L100180 13mm diameter sockets No 5.39

L100181 20mm diameter sockets No 5.56

L100182 25mm diameter sockets No 6.24

L100183 32mm diameter sockets No 6.69

L100184 40mm diameter sockets No 9.07

L100185 50mm diameter sockets No 9.18

L100186 65mm diameter sockets No 9.91

L100187 75mm diameter sockets No 10.70

L100188 100mm diameter sockets No 13.70

Disconnecting, taking out existing cast iron water mains with


spigot and socket joints or with flanged joints and removing
off site

L100189 75mm diameter m 5.15

L100190 80mm diameter m 9.75

BW-L10
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Disconnecting, taking out existing cast iron water mains with


spigot and socket joints or with flanged joints and removing
off site

L100191 100mm diameter m 11.45

L100192 150mm diameter m 13.15

Cutting into pipes (any types), taking out length not


exceeding 2.00m, removing off site and preparing to receive
new

L100193 75mm diameter No 35.60

L100194 80mm diameter No 42.77

L100195 100mm diameter No 46.61

L100196 150mm diameter No 56.13


Drilling and tapping cast iron water mains including providing
all necessary fittings, ferrules, etc for branch connections

L100197 13mm diameter No 47.20

L100198 15mm diameter No 52.49

L100199 19mm diameter No 55.90

L100200 22mm diameter No 67.07

L100201 25mm diameter No 68.00

L100202 28mm diameter No 81.65

Cutting into pipes and remaking flanged joints including


providing new rubber flange washers

L100203 100mm diameter No 61.24

L100204 150mm diameter No 72.46

BW-L11
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water service pipework (Cont'd)

Repairing burst water pipes or damaged valves including


breaking up road or concrete surfaces, excavating not
exceeding 2.00m deep, cutting off pipe and replacing new to
match existing including stainless steel clamps or heavy
bolted collars with rubber rings, backfilling and
consolidating, flushing off and making good works disturbed
(reinstatement of road surfaces concrete hardstanding,
turfing, etc measured separately) (rate per job)

L100205 Pipes not exceeding 225mm diameter No 437.40


No 108.00
L100206 Extra over for each excavating not exceeding 2m deep for
detecting pipe burst

L100207 Replacing damaged sluice/butterfly valves not exceeding 150mm No 591.84


diameter

L1 00208 Pipe detection by licenced Cable detector worker day 216.00

Stopcocks or bib-cocks, gate valves

Bronze pressure relief valves

L100209 Taking out existing stop valves or bib-cocks (any type), removing No 4.00
off site and making good works disturbed or preparing to receive
new

L100210 Fixing only stop valves or bib-cocks complete with all connections No 4.64

L1 00211 Rubber washers to stopcocks or bib-cocks in replacement No 1.51

No 7.78
L100212 Taking out existing gate valves, non-return valves. Etc

removing
off site and making good works disturbed or preparing to receive
new No 38.88

L100213 Fixing only pressure relief valves including tapping and all
connections No 105.00

L100214 Supply and replace or install rubber wash pack for 75mm dia ball
float valve including dismantling , servicing and fixing back all
fitting etc No 126.00

L100215 Supply and replace or install rubber wash pack for 100mm dia ball
float valve including dismantling , servicing and fixing back all
fitting etc
L : PLUMBING
BW-L1 2
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Stopcocks or bib-cocks, gate valves (Cont'd)


Bronze pressure relief valves (Cont'd)

L100216 No 152.25
Supply and replace or install rubber wash pack for 150mm dia ball
float valve including dismantling , servicing and fixing back all
fitting etc

L1 00217 Servicing of check valve of any made or size No 21.00

L1 00218 Servicing of ball float of any made or size No 10.50

L100219 To service and to clean the strainer of 65mm dia or smaller No 10.50

L100220 To service and to clean the strainer of 75mm dia or above No 15.75

Waste fittings and traps

Waste fittings, rubber plug only to existing chain

L100221 32mm No 2.16


2.05
L100222 38mm No 2.05

L100223 50mm No 3.24


L100224 no 0.78
Supply and install or replace 34mm dia rubber plug to existing
chain
L100225 no 1.58
Supply and install or replace 50mm dia rubber plug to existing
chain

L100226 No 2.70
Chromium plated chain to waste fittings rubber plugs including
taking out existing and removi ng off site (plugs measured
separately)

L1 00227 Refixing existing sink/basin plugs No 1.62

L1 00228 Refixing existing chains and plugs No. 1.62

Acid and corrosion resistant waste fittings including all


connections
L100229 No 0.76
Disconnecting and taking out existing waste fittings, removing off
site and preparing to receive new

BW-L13
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Waste fittings and traps (Cont'd)

Chromium plated brass bottle traps in new or replacement


including all connections and adjustment to pipes

L100230 32mm diameter No 15.12


No 16.74
L100231 38mm diameter

uPVC bottle traps in new or replacement including all


connections and adjustment to pipes

L100232 32mm diameter No 7.78


No 8.40
L100233 38mm diameter

Acid and corrosion resist ant bottle trap s in new or


replacement including all connections and adjustment to
pipes
No 56.70
L100234 38mm diameter
Water tanks

Taking out existing storage tank, removing off site including


making good works disturbed and plugging pipes (making
good for ceiling measured separately) (For storage tank not
exceeding 1,818 litres)

L100235 In any position above ground No 48.60

L100236 In any position on ground No 24.30


No 23.63
L100237 Add to above items (L100235) & (L100236) tank capacity for each
additional stage of 1,818 litres
No 52.27
L100238 Labour for fixing only stainless steel water tank in any positions
including fixing of accessories and fittings, adjustment of existing
pipes, connection to piping, cleaning and making good works
disturbed (use of crane measured separately) (rate per panel of
1200 x 1200mm)

L100239 Labour for fixing only fibreglass water tank in any positions No 34.88
including fixing of accessories and fittings, adjustment of existing
pipes, connection to piping, cleaning and making good works
disturbed (use of crane measured separately) (rate per panel of
1200 x 1200mm)

BW-L14
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water tanks (Cont'd)

Taking out existing storage tank, removing off site including


making good works disturbed and plugging pipes (making
good for ceiling measured separately) (For storage tank not
exceeding 1,818 litres) (Cont'd)
No 1,176.12
L100240 100mm diameter approved high pressure brass ball valves
complete with brass arm and brass ball float in water tanks
including taking out existing set
no 205.80
L100241 Replace 40mm dia high pressure equilibrium ball float valve
(screw end complete with float to water tank ( DZR) type including
connection, adjustment to pipes and fittings, brackets, gaskets,etc

L100242 Replace 50mm dia high pressure equilibrium ball float valve no 236.25
(screw end complete with float to water tank ( DZR) type including
connection, adjustment to pipes and fittings, brackets, gaskets,etc

L100243 Supply and install or replace 400mm diameter copper ball float to no 346.50
water tanks including connection and making good work disturbed

L100244 Supply and install level stem to 75/1 00 diameter equilibrium ball no 23.10
float valve including connection and making good work disturbed

L100245 Supply labour and equipment to install only the dilution tank which no 48.51
including necessary connections and adjustment but extra material
used will be measured separately

L100246 Drilling holes in existing storage tanks for pipe connections, No 16.09
including all necessary fittings, etc. (rate for each hole)

Water tank covers

L100247 Approved stainless steel water tank cover factory coated with No 772.20
approved epoxy coating, not exceeding 1 .50m in area (measured
on plan) of pyramoidal shape with access opening beaded edges
turned down and fixing on existing water tanks

L100248 Add to above item (L100247) for each additional increase area to m2 475.20
a maximum of 1 .50m2 (measured on plan)

L100249 Taking out existing water tank covers in any positions and No 14.36
removing off site

BW-L15
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water tanks (Cont'd)

Cleaning / flushing / sterilising, etc. water storage tank

L100250 Labour and materials for cleaning with chlorine and flushing out No 64.80
existing water storage tanks (any type) not exceeding 1.816 cubic
metres capacity (size: 1.22 x 1.22 x 1.22mm high)

L100251 Labour and materials for cleaning with chlorine and flushing out No 106.81
existing water storage tanks (any type) not exceeding 1.816 cubic
metres capacity (size: 1.22 x 1.22 x 1.22mm high) including
washing, cleaning internal surfaces and structure of water tank to
remove rust, scales, etc by using power brush and tools

L100252 Labour and materials for cleaning with chlorine and flushing out No 264.60
existing water storage tanks (any type) not exceeding 1.816 cubic
metres capacity (size: 1.22 x 1.22 x 1.22mm high) including
washing, cleaning internal surfaces and structure of water tank to
remove rust, scales, etc by using power brush and tools, sterilising
water tanks and taking sample tests to ensure that water from the
tank is fit for human consumption (rate per tank including test
report)

L100253 Add to above items (L100250) to (L100252) for each additional No 41.04
stage of 1.816 cubic metres capacity

L100254 Washing, cleaning, reconditioning and painting internal surfaces of m2 97.20


existing water tanks with approved epoxy solution and lined the
water tanks with polyethylene (PE) or other equal and approved
medium density linings all in accordance with the manufacturer's
instructions inclusive of 5 years warranty

L100255 Washing and cleaning internal surfaces and structures of water m2 5.51
tanks to remove rust, scales, etc. by using power brush and tools

No 234.79
L100256 Sterilising existing water tanks and taking sample tests to ensure
that water from the water tank not exceeding 1.816 cubic metres
capacity is fit for human consumption (rate per tank including test
report)

L1 00257 Add to above item (L1 00257) for each additional stage of 1.816 No 9.72
cubic metres capacity

L100258 Supply technician to collect water sample from water tanks or tap No 108.00
points and send water samples to approved laboratory for testing
including all testing fees (rate per sample)

BW-L16
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Water tanks (Cont'd)

Cleaning / flushing / sterilising, etc. water storage tank


(Cont'd)
m 116.64
L100259 Replacing the water tank internal mild steel braces with stainless steel
grade 316 angle section (50 x 50 x 6mm thick) complete with cleats,
bolts and nuts all in accordance with the manufacturer's
instructions

L100260 100mm diameter UPVC trapped gully complete with riser, PVC No 114.91
grating including all connections, excavation, formwork, cutting or
coring through concrete floor (if in existing building) and packing
around traps with concrete (Grade 15A) or sand and making good
surround

L100261 100mm diameter UPVC trapped gully complete with riser, PVC No 108.54
grating, setting in suspended slabs including all connections,
formwork, cutting or coring through concrete floor (if in existing
building) and packing around traps with concrete (Grade 15A) or
sand and making good surround

L100262 Washing & disinfection of water tank using non-chlorine, Calerea m2 8.40
method. All work shall include preparation, draining, testing &
commissioning in compliance with Authority guidelines.

L1 00263 Supply chlorine powder


kg 21.00
L100264 Supply 90% chlorine tablet no 36.75

Gully

Hinged gratings and frames embedded in concrete floor


including making good surrounds and taking out existing if in
replacement

L100265 100mm diameter cast iron


No 7.56
L100266 150mm diameter cast iron No 8.86

L100267 150mm square cast iron No 10.04

L100268 100mm diameter chromium plated metal No 6.37

L100269 150mm square chromium plated metal No 8.32


L100270 100mm dia chromium plated brass
No 14.18
L100271 150mm dia chromium plated brass
No 14.44
L100272 150mm square or circular uPVC
No 4.73

BW-L17
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)


Gully (Cont'd)

Gully trap gratings and frames embedded in concrete floor


including making good surrounds and taking out existing if in
replacement

L100273 150mm square or circular stainless steel No 15.55

L100274 150mm square or circular loose cast iron No 4.86

L100275 150mm square or circular loose chromium plated metal No 4.43

L100276 150mm square or circular loose uPVC No 4.43


L100277 No 11.66
uPVC floor trap/gully gratings including dismantling existing,
repositioning, cutting pipes, necessary adjustment and making
good works disturbed
L100278 No 32.40
Breaking into existing floor traps or gullys, taking out, removing off
site and make good works disturbed

L100279 100mm dia chromium plated metal perforated plate pattern grating No 8.93

L100280 150mm dia chromium plated metal perforated plate pattern grating No 9.45

L100281 150mm square plastic gully or floor trap with perforated or non No 5.78
perforated
L100282 No 3.68
150mm circular plastic gully or floor trap with perforated or non
perforated
L100283 No 2.89
75mm circular plastic gully or floor trap with perforated or non
perforated
L100284 No 13.65
150mm dia or square stainless steel with perforated or non
perforated
L100285 No 26.25
150mm square or circular stainless steel with perforated or non
perforated
L100286 No 27.30
150mm square or circular chromium plated with perforated or non
perforated

L100287 100mm dia galvanised iron wire balloon grating No 3.15

L100288 150mm dia galvanised iron wire balloon grating No 4.73

BW-L18
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Gully (Cont'd)

Gully trap gratings and frames embedded in concrete floor


including making good surrounds and taking out existing if in
replacement (Cont'd)
No 12.08
L100289 Taking out existing manhole/inspection chamber cover (any type),
removing off site and preparing surf aces to receive new or
covering up opening temporary with 25mm thick used plywood

L100290 Taking out existing manhole/inspection chamber cover (any type), No 13.72
and preparing surfaces and providing new

Connection to existing inspection chambers/manholes


including making good works disturbed

L100291 100mm diameter drainlines


No 64.58
L100292 150mm diameter drainlines No 73.98
No 77.00
L100293 Breaking into side of existing manholes, cutting into benching and
laying one new 100mm or 150mm half section salt glazed
stoneware straight channels or bend channels, making good works
disturbed and removing debris off site

L100294 Extending size of existing manholes (any depth) including No 977.83


excavation, breaking up concrete cover, brick sides, concrete
benching as necessary, removing debris off site, providing new
concrete bottom, new concrete benching, new brickwork with
rendering, new concrete cover suitably reinforced in extension,
hacking old concrete to form key, cutting tooth and bonding new to
old brickwork. (area of extension internal size only mea sured)
(new channels measured separately)

Drainage work

L100295 Raising or lowering existing manholes not exceeding 300mm No 275.40


including breaking concrete, brickwork, precast tube, re -
concreting, refixing manhole covers and frames, making good
worksdisturbed after completion, removing debris off site, etc
(irrespective of manhole sizes)

L100296 Sewer connection in 150mm or 225mm diameter sewer to No 345.82


tumbling bays, backdrops, etc in any depth including excavation,
planking and strutting, return, backfilling and disposal of surplus
excavated material of site, and including pipes, concrete, etc and
making good works disturbed

BW-L19
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)


Drainage work (Cont'd)

L100297 Sewer connection in 150mm or 225mm diameter pipe joints etc in No 172.80
any depth including excavation, planking and strutting, return,
backfilling and disposal of surplus excavated material of site, and
including pipes, concrete, etc and making good works disturbed

L100298 Taking out existing grease trap covers and removing off site No 24.30

Wash hand basins

L100299 Fixing only new wash hand basins including plugging and screwing No 48.60
the brackets to wall, making good work disturbed and making
connections and adjustments to piping (basins and brackets
measured separately)

L100300 Taking out and refixing existing wash hand basins in existing/new No 54.00
position including any necessary cutting and pinning ends of
brackets, making good work disturbed and making all connections
and adjustments to piping

L100301 Adjusting loose basin by pinning end of brackets, patching up with No 14.58
white cement etc. and making good works disturbed

L100302 Cast iron brackets for wash hand basins Pair 8.75

No 6.80
L100303 Taking out existing basins including brackets, if any, removing off
site and making good works disturbed

L100304 Taking out existing basins including brackets, if any, set aside and No 5.83
making good works disturbed

Sinks

L100305 Fixing only new sinks complete including cutting and pinning in No 48.60
ends of brackets, making good work disturbed and making all
connections and adjustments to piping (sinks and br ackets
measured separately)

L100306 Taking out existing sinks including brackets, if any, set aside for No 5.83
reuse and making good works disturbed

L100307 Taking out and refixing existing sinks in existing/new positions No 54.00
including any necessary cutting and pinning ends of brackets,
making good works disturbed and making all connections and
adjustments to piping

L100308 Cast iron brackets for sinks or trough Pair 8.75

BW-L20
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Sinks (Cont'd)

L100309 Taking out existing sinks (any type) including bracke ts, if any,
removing off site and make good works disturbed No 6.80

L100310 3mm diameter x 75mm long brass grid screws in replacement to


sinks No 1.51

Troughs

L100311 Fixing only troughs (irrespective of size) complete including cutting


and pinning in ends of brackets to walls, making good to piping No 145.80
work (trough and brackets measured separately)

L100312 Taking out existing troughs (irrespective of size) including


brackets, if any, removing off site and making good works No 12.96
disturbed

L100313 Taking out existing troughs (irresp ective of size) including


brackets, if any, set aside for reuse and making good works No 11.88
disturbed

Water closets

L100314 Fixing only squatting water closets including making connections


and adjustments to piping and making good works disturbed No 77.76

L100315 Taking out existing squatting water closets, removing off site,
preparing to receive new or stopping up drains and making good No 19.44
works disturbed

L100316 Taking out existing squatting pans, removing off site, altering soil,
waste and vent pipes connections and prepa ring surfaces to No 77.76
receive pedestal type water closet including offset, bend, etc.

L100317 Taking out existing white vitreous china foot tread plates for
squatting water closets, removing off site and replacing new Pair 19.44
including lining joints between treads and floor finishes with white
cement

L100318 White vitreous china foot tread plates for squatting water closets,
including lining joints between treads and floor finishes with white Pair 17.50
cement

L100319 Fixing only pedestal water closets including making connections


and adjustments to piping and making good works disturbed No. 68.04

L100320 Taking out and refixing pedestal water closets including making
connections and adjustments to piping and making good works No 82.62
disturbed

BW-L21
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)


Water closets (Cont'd)

L100321 Taking out existing pedestal water closet pans, removing off site, No 87.48
altering soil, waste and vent pipes connections and preparing
surfaces to receive squatting water closet pans including offset,
bend, etc.

L100322 Labour and materials for cleaning white glazed water closet pans No 4.86
or other white glazed sanitary fittings to a satisfactory finish free
from stain

L100323 Cleaning eye to water closet pan in replacement


No 4.32
Water closet seats and covers

L100324 Fixing only water closet seats and covers

L1 00325 Taking out existing lavatory seats and covers and removing off site No 2.92
No 1.08

Cisterns

L100326 Fixing only cisterns and brackets including any necessary cutting No 19.44
and pinning of brackets, and making all connections and
adjustments to piping and making good works disturbed

L100327 Fix only cistern on existing brackets including making connections No 14.58
and adjustments to piping and making good works disturbed

L100328 Taking out existing high or low level cisterns, removing off site and No 4.86
making good works disturbed

L100329 Cast iron brackets for cisterns Pair 8.75

No 21.38
L100330 Labour and materials for overhauling flushing cisterns (any type)
including replacement of small defective parts, (excluding
ballcock) and painting internally and externally if necessary

L100331 Taking out existing system syphon fittings including ball floats, ball No 29.16
valves, handles, chains and internal fittings, etc. removing off site
and replacing with new to match existing including all necessary
connections and adjustments to piping and making good works
disturbed

L100332 Taking out cistern syphon washers and replacing with new to No 2.92
match existing

L100333 Taking out existing cistern ball floats and replacing with new No 7.78
plastic ball floats including connections

BW-L22
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Flush arm/handles for cisterns


L100334 No 9.72
Approved chromium plated handles for low level cisterns in
replacement

L100335 Approved plastic handles for low level cisterns in replacement No 7.78

L100336 Approved plastic flush arm for low level cisterns No 7.78

L100337 Cast aluminium chain with handles for high level cisterns No 8.75

L1 00338 25mm dia polyvinyl chloride ball valve No 131.25

L100339 50mm dia polyvinyl chloride ball valve No 218.40

L1 00340 Cistern ball valve washer of the same size No 2.00

Flush pipes

L1 00341 Rubber cone for flush pipes to pedestal water closet connections No 4.86
L100342 No 34.02
Stainless steel flush pipe for urinal cisterns including all
connections

Urinals

Taking out existing sparge pipes for urinal and replacing with
new sparge pipes with brackets to match and connection
(rate per length of 1000mm)

L100343 13mm diameter copper sparge pipes m 9.72

L1 00344 13mm diameter chromium plated copper sparge pipes m 11.66

L1 00345 13mm diameter stainless steel sparge pipes m 11.66


Taking out existing urinal flush pipes and replacing with new
flush pipes including providing necessary tee connections

L1 00346 30mm diameter chromium plated copper flush pipes No 36.94

L100347 30mm diameter stainless steel flush pipes No 36.94

L100348 30mm diameter upvc flush pipes No 7.78

L1 00349 Taking out existing traps to urinal and removing off site No 1.51

L100350 Brass waste and domical gratings for urinals No 24.30

BW-L23
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Urinals (Cont'd)

Taking out existing urinal flush pipes and replacing with new
flush pipes including providing necessary tee connections
(Cont'd)
No 19.44
L100351 Chromium plated waste and domical gratings for urinals

Flush valves

L100352 Fixing only exposed flush valves including making connections No 23.22
and adjustments to piping and making good works disturbed

L100353 Fixing only concealed flush valves including making connections No 27.86
and adjustments to piping and making good works disturbed

Soap holders

L100354 Taking out existing soap holders built-in wall, removing off site and No 11.34
preparing to receive new or making good with wall tiles to match
existing including cutting out wall tiles and making good works
disturbed

Toilet paper holders

L100355 Taking out existing white glazed vitreous china toilet paper holders No 4.86
built in wall, removing off site and preparing to receive new or
making good with wall tiles to match existing including cutting out
wall tiles and making good works disturbed

L100356 Taking out existing chromium plated toilet paper holders built in No 4.86
wall, removing off site and preparing to receive new or making
good with wall tiles to match existing including cutting out wall tiles
and making good works disturbed

L100357 Approved wooden or plastic rollers fixed to existing brackets No 2.16

Towel rails

L100358 Fixing only towel rails including plugging and screwing to walls
No 3.89
No 1.94
L100359 Taking out towel rails including brackets, removing off site

and
making good works disturbed No 5.83

L100360 Taking out towel rails including brackets, refixing with new
chromium plated screws and making good works disturbed

BW-L24
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Shower fittings

L1 00361 Taking out adjustable shower roses and removing off site No 1.94
L100362 No 1.94
Taking out shower mixer or spray shower completely and
removing off site
L100363 No 9.72
Fixing only shower mixer or spray shower complete including
plugging and screwing to wall, making connections and adjustment
to piping
L100364 No 4.86
Fixing only fixed shower head with ball swivel arm and flanges
including connections and adjustments to piping
L100365 No 44.71
50mm to 150mm diameter chromium plated brass adjustable
shower rose including connections

L100366 Remove shower mixer tap for shower spray set no 2.63

Sundries

Labour for fixing of sanitary appliances or fittings

L100367 Squatting pan water closets No 162.00

L100368 Pedestal water closets No 135.00

L100369 Single bowl urinals No 75.06

L1 00370 Undercounter / wall hung wash hand basins No 72.50

L100371 Sinks No 73.76

L100372 Exposed flush valves No 37.48

L100373 Concealed flush valves No 46.33

L100374 Taps No 8.40

Labour for clearing blockage

L100375 Gully or floor traps (ground floor) No 45.00

L100376 Floor traps on upper floor No 50.00

L1 00377 Soil and waste stack and branches (rate per job) No 71.00
L100378 No 90.00
Reusing stack and branches (rate per stack) (new material
measured separately)

BW-L25
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Sundries (Cont'd)

Labour for clearing blockage (Cont'd)

L100379 Waste pipe to wash basin or sink (rate per job) No 27.00

L100380 Water closet pans No 30.00

Manholes

L1 00381 Not exceeding 1 .50m deep (rate per job) No 97.20

L1 00382 Manhole not exceeding 1.25 m deep (rate per job) No 98.00

L100383 Exceeding 1 .50m and not exceeding 3.00m deep No 121.50

L1 00384 Ditto exceeding 1.25 m and not exceeding 2.50 m deep (ditto) No 112.50

L100385 Exceeding 3.00m and not exceeding 4.00m deep No 174.96

L100386 Ditto exceeding 2.50 m and not exceeding 3.75 m deep (ditto) No 157.00

Drainlines (measured from maholes to manholes (rate per


job)

L100387 100mm drain pipe not exceeding 50m length No 100.00

L100388 150mm drain pipe not exceeding 50m length No 135.00

High power vacuum clearing and cleaning of grease traps

L100393 Not exceeding 2.00m deep No 102.60

L100394 Exceeding 2.00mm and not exceeding 4.00m deep No 145.80

Other sundry works


L100395 m 1.19
Taking out existing pipes (any types and sizes) fixed to wall,
chased in floor or laid in trench including taking out holder bolts
and removing debris off site (trench measured separately)

L100396 No 3.85
Repairing leaking joints of galvanised steel, copper, and other
pipes (except asbestos) (number of joints measured)

L100397 No 29.16
Hacking and making good leaks in concrete surround to floor traps
on upper floors with waterproof cement mortars
L100398 Providing and forming cement surrounds at base of water closets, No 5.83
flush pipes and squatting pans joints to cure leaks

BW-L26
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 00000 PLUMBING (CONT'D)

Sundries (Cont'd)

Other sundry works (Cont'd)

L1 00399 No 3.24
Hacking out existing pointing at joints between sinks or basins and
walls and repointing with white cement

L100400 O' rings for self closing tap No 2.10

L1 00401 Nut or washer for self closing tap No 6.30

L1 00402 Filter or plate for self closing tap No 6.30


L100403 No 5.25
Remove, dismantle, service, assemble and refix for taps (any
type) (parts replacement measured separately)

L100404 Water tap box No 10.50

L100405 Brass padlock for tap box No 4.20

L100406 To vacuum waste from gully trap No 157.50


L100407 Disconnect and take out existing waste fitting, remove off site and No 2.10
prepare to receive new work

L200000 SANITARY PIPEWORK

Medium grade coated cast iron soil, waste, ventilating and


anti-syphonage pipes complying with SS 33 including spigot
and socket joints

L200001 50mm diameter pipes fixed to walls or ceilings with holderbats m 28.19
L200002 m 26.78
50mm diameter pipes laid in trenches or chased in floors (trench
excavation and chasing floor measured separately)

L200003 75mm diameter pipes fixed to walls or ceilings with holderbats m 31.43
L200004 m 30.02
75mm diameter pipes laid in trenches or chased in floors (trench
excavation and chasing floor measured separately)

L200005 100mm diameter pipes fixed to walls or ceilings with holderbats m 41.69
L200006 m 40.28
100mm diameter pipes laid in trenches or chased in floors (trench
excavation and chasing floor measured separately)

BW-L27
L : PLUMBING

L200007 150mm diameter pipes fixed to walls or ceilings with holderbats m 56.92
L200008 m 47.29
150mm diameter pipes laid in trench or cahsed in floor (trench
excavation and chasing floor measured separately)

BW-L28
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L200000 SANITARY PIPEWORK (CONT'D)

Medium grade coated cast iron soil, waste, ventilating and


anti-syphonage pipes complying with SS 33 including spigot
and socket joints (Cont'd)

Extra over pipes for fittings

L200009 75mm diameter bends/elbows No 19.77

L20001 0 100mm diameter bends/elbows No 21.60

L20001 1 150mm diameter bends/elbows No 50.00

L20001 2 75 x 75 x 75mm diameter tees No 28.30

L200013 100 x 100 x 100mm diameter tees No 34.34

L200014 150 x 150 x 150mm diameter tees No 67.18

L200015 75 x 50mm diameter reducers No 36.29

L200016 100 x 75mm reducers No 41.15

L200017 150 x 100mm diameter reducers No 66.64

Hubless cast iron soil, waste, ventilating and anti-syphonage


pipes

L200018 50mm diameter pipes fixed to walls or ceilings with holderbats m 68.04
L200019 m 64.80
50mm diameter pipes laid in trenches or chased in floors (trench
excavation and chasing floor measured separately)

L200020 75mm diameter pipes fixed to walls or ceilings with holderbats m 73.44
L200021 m 70.20
75mm diameter pipes laid in trenches or chased in floors (trench
excavation and chasing floor measured separately)

L200022 100mm diameter pipes fixed to walls or ceilings with holderbats m 102.60
L200023 m 100.44
100mm diameter pipes laid in trenches or chased in floors (trench
excavation and chasing floor measured separately)

L200024 150mm diameter pipes fixed to walls or ceilings with holderbats m 136.08
L200025 m 135.00
150mm diameter pipes laid in trench or chased in floor (trench
excavation and chasing floor measured separately)

BW-L29
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L200000 SANITARY PIPEWORK (CONT'D)

Hubless cast iron soil, waste, ventilating and anti-syphonage


pipes (Cont'd)

Extra over pipes for fittings

L200026 75mm diameter bends/elbows No 19.76

L200027 100mm diameter bends/elbows No 21.60

L200028 150mm diameter bends/elbows No 50.00

L200029 75 x 75 x 75mm diameter tees No 31.32

L200030 100 x 100 x 100mm diameter tees No 36.72

L200031 150 x 150 x 150mm diameter tees No 88.56

L200032 75 x 50mm diameter reducers No 16.20

L200033 100 x 75mm reducers No 20.52

L200034 150 x 100mm diameter reducers No 28.08

Unplasticised polyvinyl chloride soil, waste, ventilating and


anti-syphonage pipes complying with SS 272 including
solvent cement joints

Rates for pipes 50mm diameter and below shall be deemed to


include all elbow s, bends, tees, juctions, inspection
openings, reducers and similar pipe fittings

Pipes fixed in any positions

L200035 32mm diameter m 10.80

L200036 40mm diameter m 13.82

L200037 50mm diameter m 14.80

L200038 65mm diameter m 16.63

L200039 80mm diameter m 17.60

L200040 75mm diameter m 62.64

L200041 100mm diameter m 79.92

BW-L30
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L200000 SANITARY PIPEWORK (CONT'D)

Unplasticised polyvinyl chloride soil, waste, ventilating and


anti-syphonage pipes complying with SS 272 including
solvent cement joints (Cont'd)

L200042 150mm diameter m 108.00

Extra over pipes for fittings

L200043 65mm diameter bends/elbows No 11.02

L200044 80mm diameter bends/elbows No 11.56

L200045 100mm diameter bends/elbows No 14.15

L200046 150mm diameter bends/elbows No 33.05

L200047 65 x 65 x 65mm diameter tees No 23.54

L200048 80 x 80 x 100mm diameter tees No 24.52

L200049 100 x 100 x 100mm diameter tees No 25.06

L200050 150 x 150 x 150mm diameter tees No 39.96

L200051 80 x 50mm diameter reducers No 14.15

L200052 100 x 80mm diameter reducers No 19.22

L200053 150 x 100mm diameter reducers No 23.54

Unplasticised polyvinyl chloride vent cowls

L200054 100mm diameter No 11.23

L200055 150mm diameter No 14.47

Acid and corrosion resistant pipes complying with BS 4991


including mechanical joints fixed to walls or ceilings with
holderbats or laid in chased concrete or in trenches (chasing
concrete or trench excavation measured separately)

Rates for pipes 50mm diameter and below shall be deemed to


incl ude a ll el bow s, be nds, tees , j uctions, inspec ti on
openings, reducers and similar pipe fittings

L200056 40mm diameter m 45.36

L200057 50mm diameter m 57.24

L200058 75mm diameter m 113.40

BW-L31
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L200000 SANITARY PIPEWORK (CONT'D)

Acid and corrosion resistant pipes complying with BS 4991


including mechanical joints fixed to walls or ceilings w ith
holderbats or laid in chased concrete or in trenches (chasing
concrete or trench excavation measured separately) (Cont'd)

Rates for pipes 50mm diameter and below shall be deemed to


include all elbow s, bends, tees, juctions, inspection
openings, reducers and similar pipe fittings (Cont'd)

Extra over pipes for fittings

L200059 75mm diameter bends/elbows No 113.40

L200060 75 x 75 x 75mm diameter tees No 125.28

L200061 76 x 50mm diameter reducers No 57.24

Acid and corrosion resistant floor traps 'P' or 'S' type with
75mm deep seals, 150mm diameter raising piece, 75mm or
100mm diameter outgo and necessary side inlets, uPVC
hinged gratings including all connections, cutting or coring
through concrete floors

L200062 Setting in suspended slabs including all necessary formwork No 320.11


L200063 Setting traps in floors and packing around with concrete (grade 15) No 399.60
including all necessary excavation, disposal and formwork

L300000 WATER SERVICE PIPEWORK

Medium duty galvanised steel pipes complying with SS 17


with approved internal linings including screw joints fixed to
walls or ceilings with holderbats or laid in chased concrete or
in trenches (chasing concrete or trench excavation measured
separately)

Rates for pipes 50mm diameter and below shall be deemed to


include all elbows, bends, tees, junctions, inspection
openings, reducers and similar pipe fittings

L300001 15mm diameter m 36.72

L300002 20mm diameter m 43.20

L300003 25mm diameter m 49.68

L300004 32mm diameter m 56.16

BW-L32
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L300000 WATER SERVICE PIPEWORK (CONT'D)

Medium duty galvanised steel pipes complying with SS 17


with approved internal linings including screw joints fixed to
walls or ceilings with holderbats or laid in chased concrete or
in trenches (chasing concrete or trench excavation measured
separately) (Cont'd)

Rates for pipes 50mm diameter and below shall be deemed to


include all elbows, bends, tees, junctions, inspection
openings, reducers and similar pipe fittings (Cont'd)

L300005 40mm diameter m 60.48

L300006 50mm diameter m 71.28

L300007 65mm diameter m 91.80

L300008 80mm diameter m 104.76

L300009 100mm diameter m 129.60

Extra over pipes for fittings

L300010 65mm diameter bends/elbows No 19.66

L30001 1 80mm diameter bends/elbows No 29.05

L300012 100mm diameter bends/elbows No 35.75

L30001 3 65 x 65 x 65mm diameter tees No 28.40

L300014 80 x 80 x 80mm diameter tees No 37.58

L300015 100 x 100 x 100mm diameter tees No 51.84

L30001 6 65 x 50mm diameter reducers No 21.28

L300017 80 x 65mm diameter reducers No 25.49

L300018 100 x 80mm diameter reducers No 30.56

BW-L33
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L300000 WATER SERVICE PIPEWORK (CONT'D)

Stainless steel pipes complying with BS 2127 Type 304


including compression joints to BS 864 Part 2 fixed to walls
or ceilings with holderbats or laid in chased concrete or in
trenches (chasing concrete or trench excavation measured
separately)

Rates for pipes 50mm diameter and below shall be deemed to


include all elbows, bends, tees, junctions, in spection
openings, reducers and similar pipe fittings

L300019 20mm diameter m 31.32

L300020 25mm diameter m 34.56

L300021 32mm diameter m 39.96

L300022 40mm diameter m 44.28

L300023 50mm diameter m 63.72

L300024 76mm diameter m 84.24

Extra over pipes for fittings

L300025 76mm diameter bends/elbows No 50.76

L300026 76 x 76 x 76mm diameter tees No 72.36

L300027 76 x 65mm diameter reducers No 68.04

Copper pipes complying with BS 2871 Part 1 Table


X including compression joints to BS 864 Part 2 fixed to walls
or ceilings with holderbats or laid in chased concrete
(chasing concrete measured separately)

Rates for pipes 50mm diameter and below shall be deemed to


include all elbows, bends, tees, junctions, inspection
openings, reducers and similar pipe fittings

L300028 15mm diameter m 22.68

L300029 20mm diameter m 27.00

L300030 25mm diameter m 30.24

L300031 32mm diameter m 36.72

L300032 40mm diameter m 45.00

L300033 50mm diameter m 54.00

BW-L34
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L300000 WATER SERVICE PIPEWORK (CONT'D)

Copper pipes complying with BS 2871 Part 1 Table X


including compression joints to BS 864 Part 2 fixed to walls
or ceilings with holderbats or laid in chased concrete
(chasing concrete measured separately) (Cont'd)

Rates for pipes 50mm diameter and below shall be deemed to


include all elbows, bends, tees, junctions, inspection
openings, reducers and similar pipe fittings (Cont'd)
L300034 m 64.00
67mm diameter
L300035 76mm diameter m 108.00

Copper pipes complying with BS 2871 Part 1 Table Y


including compression joints to BS 864 Part 2 B242

Rates for pipes 50mm diameter and below shall be deemed to


include all elbows, bends, tees, juctions, inspection
openings, reducers and similar pipe fittings

L300036 15mm diameter m 23.76

L300037 20mm diameter m 28.08

L300038 25mm diameter m 36.00

L300039 32mm diameter m 38.88

L300040 35mm diameter m 50.00

L300041 40mm diameter m 55.00

L300042 50mm diameter m 63.00

L300043 65mm diameter m 75.00

L300044 76mm diameter m 111.24

Extra over pipes for compression fittings (Table X and Y)

L300045 65mm diameter bends/elbows No 39.96

L300046 76mm diameter bends/elbows No 50.76

L300047 65 x 65 x 65mm diameter tees No 57.24

L300048 76 x 76 x 76mm diameter tees No 73.44

BW-L35
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L300000 WATER SERVICE PIPEWORK (CONT'D)

Copper pipes complying with BS 2871 Part 1 Table Y


including compression joints to BS 864 Part 2 B242 (Cont'd)

Extra over pipes for compression fittings (Table X and Y) (Cont'd)

L300049 76 x 50mm diameter reducers No 61.56

L300050 76 x 65mm diameter reducers No 73.44

L300051 65mm diameter couplings No 50.76

L300052 76mm diameter couplings No 57.24


Unplasticised polyvinyl chloride pipe complying with SS 141
including solvent cement joints fixed to walls or ceilings with
holderbats or laid in chased concrete or in trenches (chasing
concrete or trench excavation measured separately)

Rates for pipes 50mm diameter and below shall be deemed to


include all elbow s, bends, tees, juctions, inspection
openings, reducers and similar pipe fittings

Pipes fixed in any positions

L300053 15mm diameter m 10.80

L300054 20mm diameter m 12.96

L300055 25mm diameter m 16.20

L300056 32mm diameter m 22.68

L300057 40mm diameter m 27.00

L300058 50mm diameter m 30.24

L300059 65mm diameter m 43.20

L300060 80mm diameter m 64.80

L300061 100mm diameter m 84.24

L300062 150mm diameter m 95.04

BW-L36
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L300000 WATER SERVICE PIPEWORK (CONT'D)

Unplasticised polyvinyl chloride pipe complying with SS 141


including solvent cement joints fixed to walls or ceilings with
holderbats or laid in chased concrete or in trenches (chasing
concrete or trench excavation measured separately) (Cont'd)

Rates for pipes 50mm diameter and below shall be deemed to


include all el bow s, bends, tees, juctions, inspection
openings, reducers and similar pipe fittings (Cont'd)

Extra over pipes for fittings

L300063 65mm diameter bends/elbows No 20.74

L300064 80mm diameter bends/elbows No 21.92

L300065 100mm diameter bends/elbows No 30.56

L300066 150mm diameter bends/elbows No 37.69

L300067 65 x 65 x 65mm diameter tees No 22.14

L300068 80 x 80 x 80mm diameter tees No 24.08

L300069 100 x 100 x 100mm diameter tees No 57.24

L300070 150 x 150 x 150mm diameter tees No 68.04

L300071 80 x 65mm diameter reducers No 24.84

L300072 100 x 80mm diameter reducers No 27.00

L300073 150 x 100mm diameter reducers No 52.92

L300074 80mm diameter sockets No 25.38

L300075 100mm diameter sockets No 48.60

L300076 150mm diameter sockets No 54.00

BW-L37
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L300000 WATER SERVICE PIPEWORK (CONT'D)

Ductile iron pipe complying with BS 4772 Class K9 with


internal linings including spigot and socket joints fixed to
walls or ceilings with holderbats or in trenches (trench
excavation measured separately)

L300077 60mm diameter m 88.00

L300078 80mm diameter m 102.60

L300079 100mm diameter m 113.40

L300080 125mm diameter m 136.80

L300081 150mm diameter m 170.64

Extra over pipes for fittings

L300082 80mm diameter bends/elbows No 62.64

L300083 100mm diameter bends/elbows No 73.44

L300084 150mm diameter bends/elbows No 130.68

L300085 80 x 80 x 80mm diameter tees No 79.92

L300086 100 x 100 x 100mm diameter tees No 136.08

L300087 150 x 150 x 150mm diameter tees No 227.88

L300088 100 x 80mm diameter reducers No 96.12

L300089 150 x 100mm diameter reducers No 125.28

Ductile iron pipe complying with BS 4772 Class K9 with


internal linings with flanged joint type fixed to walls or
ceilings with holderbats or in trenches (trench excavation
measured separately)

L300090 60mm diameter m 78.90

L300091 80mm diameter m 97.85

L300092 100mm diameter m 118.80

L300093 125mm diameter m 133.67

L300094 150mm diameter m 167.51

BW-L38
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L300000 WATER SERVICE PIPEWORK (CONT'D)

Ductile iron pipe complying with BS 4772 Class K9 with


internal linings with flanged joint type fixed to walls or
ceilings with holderbats or in trenches (trench excavation
measured separately) (Cont'd)

Extra over pipes for fittings

L300095 80mm diameter bends/elbows No 47.00

L300096 100mm diameter bends/elbows No 82.30

L300097 150mm diameter bends/elbows No 129.06

L300098 80 x 80 x 80mm diameter tees No 91.48

L300099 100 x 100 x 100mm diameter tees No 118.91

L300100 150 x 150 x 150mm diameter tees No 170.42

L300101 100 x 80mm diameter reducers No 96.12

L300102 150 x 100mm diameter reducers No 150.66

L300103 80mm diameter blank flanges No 30.56

L300104 100mm diameter blank flanges No 45.90

L300105 150mm diameter blank flanges No 75.49

L300106 80mm diameter sockets No 40.93

L300107 100mm diameter sockets No 62.10

L300108 150mm diameter sockets No 87.91

L3001 09 80mm diameter flange drilled to size No 62.53

L3001 10 100mm diameter flange drilled to size No 43.63


L3001 11 150mm diameter flange drilled to size No 61.99

L400000 VALVES

Cast iron sluice valves complying with BS 5163

L400001 80mm diameter No 170.10

L400002 100mm diameter No 206.60

BW-L39
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L400000 VALVES (CONT'D)

Cast iron sluice valves complying with BS 5163 (Cont'd)

L400003 150mm diameter No 307.80

L400004 200mm diameter No 526.50

Bronze non-return valves

L400005 80mm diameter No 243.00

L400006 100mm diameter No 299.70


L400007 150mm diameter No 433.40

L500000 STOPCOCKS OR BIB-COCKS, GATE VALVES

Brass screwdown bibcocks / stopcocks complying with SS 75


including crutch handles and accessories

L500001 13mm diameter No 8.10

L500002 15mm diameter No 24.84

L500003 20mm diameter No 33.48

L500004 25mm diameter No 41.04

L500005 32mm diameter No 55.08

L500006 40mm diameter No 83.16

L500007 50mm diameter No 95.04

L500008 65mm diameter No 275.40

Brass high pressure screwdown stopcock/ bibcock with


crutch handle include connection, adjustment to pipes and
fittings, brackets, painting etc

L500009 15mm diameter No 12.08

L500010 20mm diameter No 18.90

L50001 1 25mm diameter No 42.00

L500012 65mm diameter No 173.25

L500013 32mm diameter No 89.25

L500014 50mm diameter No 163.08

BW-L40
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L500000 STOPCOCKS OR BIB-COCKS, GATE VALVES (CONT'D)

Brass taps with hose nozzle

L500015 13mm diameter No 12.64

Chromium plated easy clean stopcocks or bibcocks with


crutch or approved handles

L500016 13mm diameter No 15.55

L500017 15mm diameter no 17.00

L500018 20mm diameter no 23.00

Chromium plated capstan heed stopcocks or bibcocks

L500019 13mm diameter No. 15.55

Brass gate valves complying with BS 5154 including wheel


handles

L500020 15mm diameter No 14.80

L500021 20mm diameter No 18.04

L500022 25mm diameter No 23.33

L500023 32mm diameter No 25.92

L500024 40mm diameter No 33.00

L500025 50mm diameter No 46.80

L500026 65mm diameter No 64.90

L500027 80mm diameter No 184.68

L500028 100mm diameter No 214.92

L500029 75mm diameter No 71.00

Brass non-return valves/check valves

L500030 15mm diameter No. 18.36

L500031 20mm diameter No. 20.52

L500032 25mm diameter No. 27.00

L500033 32mm diameter No. 40.00

L500034 40mm diameter No. 43.20

BW-L41
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L500000 STOPCOCKS OR BIB-COCKS, GATE VALVES (CONT'D)

Brass non-return valves/check valves (Cont'd)

L500035 50mm diameter No. 55.08

L500036 65mm diameter No. 214.92

L500037 80mm diameter No. 302.40

L500038 100mm diameter No. 378.00

Bronze pressure relief valves

L500039 240 - 600 kpa (30 - 75 psi) No 268.27

L500040 1000 - 1600 kpa (75 - 125 psi) No 621.15

Approved high pressure brass ball valves complying with BS


1212 complete with copper arms and plastic ball float to BS
2456 (in new or replacement)

L500041 13mm diameter No 29.91

L500042 19mm diameter No 44.93

L500043 25mm diameter No 74.74

Approved high pressure brass ball valves complying with BS


1212 complete with copper arms and copper ball float to BS
1968

L500044 13mm diameter No 32.07

L500045 19mm diameter No 76.57

L500046 25mm diameter No 116.21

L500047 32mm diameter No 210.17

L500048 38mm diameter No 240.62

L500049 50mm diameter No 301.64

Approved high pressure brass ball valves complete with


copper arm, copper ball float, stainless steel flange with
copper socket

L500050 75mm diameter No 855.36

L500051 100mm diameter No 980.10

L500052 150mm diameter No 1,166.40

BW-L42
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L600000 WASTE FITTINGS AND TRAPS

Waste fittings, rubber plug with chromium plated chain

L600001 32mm No 4.86

L600002 38mm No 7.99

L600003 50mm No 9.07

L600004 34mm dia rubber plug with chrominium plated fitting no 2.10

L600005 44mm dia rubber plug with chrominium plated fitting no 2.89
L600006 no 33.60
Supply and replace or install 32mm dia pop up waste fitting for
wash basin complete with PVC bottle trap

Chromium plated waste fittings including all connections

L600007 32mm diameter No 3.35

L600008 38mm diameter No 3.85

Plastic waste fittings including all connections

L600009 32mm diameter No 5.95

L600010 38mm diameter No 7.40

Acid and corrosion resistant waste fittings including all


connections

L60001 1 38mm diameter No 26.24

Chromium plated brass bottle traps in new including all


connections and adjustment to pipes

L600012 32mm diameter No 15.12


L600013 No 16.74
38mm diameter

uPVC bottle traps in new including all connections and


adjustment to pipes

L600014 32mm diameter No 7.78

L600015 38mm diameter No 7.78

Acid and corrosion resistant bottle traps in new including all


connections and adjustment to pipes

L600016 38mm diameter No 56.70

BW-L43
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L600000 WASTE FITTINGS AND TRAPS (CONT'D)

Strainer in new or replacement including brackets,


connection, adjustment to pipes and fittings and painting

L600017 15mm diameter no 21.00

L600018 20mm diameter no 26.25

L600019 25mm diameter no 36.75

L600020 32mm diameter no 47.30

L600021 40mm diameter no 63.00

L600022 50mm diameter no 78.80

L600023 65mm diameter no 110.25

L600024 75mm diameter no 220.50

L600025 100mm diameter no 399.00

L600026 150mm diameter no 682.50


L600027 200mm diameter no 966.00

L700000 FLEXIBLE TUBES

L700001 No 5.60
13mm diameter x 300mm stainless steel flexible tube complete
with two washers and connectors
L700002 no 3.00
13mm dia x 100mm stainless steel flexible tube complete with 2
nos. of washers and connectors

L700003 13mm dia up to 600mm stainless steel flexible tube complete with no 5.00
2 nos. of washers and connectors
L700004 no 8.00
13mm dia exceeding 600mm stainless steel flexible tube complete
with 2 nos. of washers and connectors
L700005 No 4.32
13mm diameter x 300mm chromium plated flexible tube complete
with two washers and connectors

L700006 No 8.00
Stainless steel flexible tube for shower complete with 2 nos. of
washers and connectors

BW-L44
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L800000 WATER TANKS

2.5mm thick pressed stainless steel (grade 316) water tank,


complete with stainless steel covers, access openings,
stainless steel cleats, stays, bolts, nuts, washers, flanges,
fittings, external aluminium ladders and internal stainless
steel ladders and all other accessories and fittings (use of
crane measured separately)

L800001 4800 mm x 2400 mm x 2400 mm No 26,100.00

L800002 3600 mm x 2400 mm x 2400 mm No 20,880.00

L800003 2400 mm x 2400 mm x 2400 mm No 15,660.00

L800004 1200 x 1200 x 1200mm high (without ladders) No 5,045.76

L800005 2400 x 1200 x 1200mm high No 7,989.08

L800006 3600 x 1200 x 1200mm high No 11,668.21

L800007 4800 x 1200 x 1200mm high No 14,779.26

L800008 2400 x 2400 x 2400mm high No 21,780.58

L800009 3600 x 2400 x 2400mm high No 24,892.27

L800010 4800 x 2400 x 2400mm high No 30,824.28


L80001 1 No 106.92
Add for above items for tank factory coated with approved epoxy
coating (rate per panel of 1200 x 1200mm)

Glass reinforced plastic press-moulded sectional water tank


complying with SS 245 complete with inlets, outlets, drains,
airvent covers, internal and external ladders (use of crane
measured separately)

L800012 1000 mm x 1000 mm x 2500 mm high No 4,832.10

L800013 1000 mm x 2000 mm x 2500 mm high No 7,392.60

L800014 1000 mm x 3000 mm x 2500 mm high No 9,693.00

L800015 1000 mm x 4000 mm x 2500 mm high No 12,074.40

L800016 1000 mm x 5000 mm x 2500 mm high No 14,454.00

L800017 2000 mm x 2000 mm x 2500 mm high No 10,494.00

L800018 2000 mm x 3000 mm x 2500 mm high No 13,592.70

L800019 2000 mm x 4000 mm x 2500 mm high No 16,718.40

BW-L45
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L800000 WATER TANKS (CONT'D)

Glass reinforced plastic press-moulded sectional water tank


complying with SS 245 complete with inlets, outlets, drains,
airvent covers, internal and external ladders (use of crane
measured separately) (Cont'd)

L800020 2000 mm x 5000 mm x 2500 mm high No 19,790.10

L800021 1000 mm x 1000 mm x 2000 mm high No 3,462.30

L800022 1000 mm x 2000 mm x 2000 mm high No 5,539.50

L800023 1000 mm x 4000 mm x 2000 mm high No 9,694.80

L800024 1000 mm x 1000 mm x 1500 mm high No 2,653.20

L800025 2000 mm x 1500 mm x1 500 mm high No 5,713.20

L800026 2000 mm x 2000 mm x1 500 mm high No 8,695.80

L800027 1000 x 1000 x 1000mm high (without ladders) No 1,978.20

L800028 1000 x 2000 x 1000mm high No 3,303.00

L800029 1000 x 3000 x 1000mm high No 4,624.20

L800030 1000 x 4000 x 1000mm high No 6,606.00

L800031 2000 x 2000 x 1000mm high No 5,284.00

L800032 2000 x 3000 x 1000mm high No 7,266.60

L800033 2000 x 4000 x 1000mm high No 9,248.40

L800034 2000 x 1000 x 2000mm high No 5,284.80

L800035 3000 x 1000 x 2000mm high No 7,266.60

L800036 4000 x 1000 x 2000mm high No 9,248.40

L800037 2000 x 2000 x 2000mm high No 10,830.78

L800038 3000 x 2000 x 2000mm high No 13,925.30

L800039 4000 x 2000 x 2000mm high No 18,399.74


L800040 m 110.16
Aluminium ladders of approved design and size for use in water
tank

BW-L46
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L800000 WATER TANKS (CONT'D)

Water tank covers

L800041 Approved stainless steel water tank cover factory coated with
approved epoxy coating, not exceeding 1 .50m2 in area (measured No 772.20
on plan) of pyramoidal shape with access opening beaded edges
turned down and fixing on existing or new water tanks

L800042 Add to above item (L8000041) for each additional increase area
to a maximum of 1 .50m2 (measured on plan) m2 475.20

Epoxy coating to water tanks

L800043 Preparing and applying 0.30mm - 0.50mm thick epoxy coating to


internal surfaces and structure of water tanks m2 46.80

Lining internal faces of tank walls and bases with 2mm thick
approved HDPE high density polyethylene sheet all in
accordance with the manufacturer's instructions including
dismantling all tank covers, cleaning, scraping/brushing to
remove loose rust and scales, applying one coat of approved
rust converter. (inclusive of 5 years warranty)

L800044 Height of tanks 1200mm or up to 2400mm


m2 108.00
L800045 Height of tanks 2400mm and above
m2 120.20
m2 10.69
L800 046 Preparing a nd applying one co at of appro ved ru st
converter/transformer to the internal surfaces and structure of
water tanks

L900000 DILUTION TANK

L900001 Supplying only 737 x 559 x 559mm deep fibreglass dilution tanks
(grey colour) complete with waste pipes (extra piping measured No 605.56
separately)

L1 000000 STOPCOCK PITS

L1000001 Cast iron stopcock pits 225 x 225 x 225mm with locking devices of
approved patterns including necessary excavation, concrete base No 132.30
and brickwork

BW-L47
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1100000 STOPCOCK BOXES

L1100001 No 58.32
Galvanised steel stopcock boxes 125 x 125 x 125mm complete
with hinges and hooks to receive and including 25mm brass
padlocks

L1100002 125mm x 125mm x 125mm PVC stopcock box with hinges and No 44.00
hooks including 25mm brass padlock

L1 200000 VALVE CHAMBERS

L1200001 Approved cast iron valve chambers with covers and frames 225 x No 191.38
225 x 400mm including 25mm brass padlocks

L1 300000 STOPCOCK CHAMBERS

L1300001 No 62.80
Concrete chambers 225 x 225 x 225mm for stopcocks including
precast concrete cover slabs

L1300002 Concrete chambers 225 x 225 x 225mm for stopcocks including 150 No 108.00
x 150mm cast iron covers

L1300003 225m x 225mm x 225mm concrete chamber for stopcock with No 135.00
6mm thick 150mm x150mm aluminium checker plate cover
including necessary excavation, concrete base and brickwork
L1300004 225m x 225mm x 225mm PVC stopcock pit with locking device of No 96.00
approved pattern including necessary excavation, concrete base
and brickwork

L1 400000 DRAINAGE WORK

Drain excavation

Excavating trenches minimum 340mm wide for 100mm


diameter pipes including backfilling and disposal of surplus
excavated material

L1400001 Not exceeding 2.00m deep, average 1000mm deep m 14.26

L1400002 Add or deduct for each stage of 250mm average depth m 3.56

Trench minimum 450 mm wide and Not exceeding 2.00 m


deep commencing from Formation level

L1400003 Average 1.50 m deep to fall m 8.20

L1400004 Add / Deduct for each stage of 200 mm average depth m 1.10

BW-L48
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

Trench minimum 600 mm wide and exceeding 2.00 m and not


exceeding 4.00 m deep commencing from formation level

L1400005 Average 3.00 mm deep to falls


m 20.80
m 1.40
L1400006 Add / Deduct for each stage of 200 mm average depth

Trench minimum 750 mm wide and exceeding 4.00 m deep


and not exceeding 6.00 m deep commencing from formation
level

L1400007 Average 5.00 mm deep to falls


m 42.50
m 1.70
L1400008 Add / Deduct for each stage of 200 mm average depth

Excavating trenches minimum 490mm wide for 150mm


diameter pipes including backfilling and disposal of surplus
excavated material

L1400009 Not exceeding 2.00m deep, average 1000m deep


m 16.42
L1400011 Exceeding 2.00 and not exceeding 4.00m deep, average 3000mm m 4.10
L1400010 Add or deduct for each stage of 250mm average depth
deep
m 65.34
L1400012 Add or deduct for each stage of 250mm average depth

Trench minimum 600 mm wide and not exceeding 2.00 m m 5.51


deep commencing from Formation Level

L1400013 Average 1.50 m deep to fall

L1400014 Add / Deduct for each stage of 200 mm average depth


m 11.80
Trench minimum 750 wide and exceeding 2.00 m and not m 1.60
exceeding 4.00 m deep commencing from Formation Level

L1400015 Average 3.00 mm deep to falls

L1400016 Add / Deduct for each stage of 200 mm average depth


m 30.10
m 2.10

BW-L49
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

Drain excavation (Cont'd)

Trench minimum 900 mm wide and exceeding 4.00 m and not


exceeding 6.00 m deep commencing from formation level

L1400017 Average 5.00 mm deep to falls m 61.30


m 2.40
L1400018 Add / Deduct for each stage of 200 mm average depth

Excavating trenches minimum 720mm wide for 225mm


diameter pipes including backfilling and disposal of surplus
excavated material

L1400019 Not exceeding 2.00m deep, average 1000m deep


m 29.92
L1400020 Add or deduct for each stage of 250mm average depth m 4.97
L1400021 Exceeding 2.00 and not exceeding 4.00m deep, average 3000mm m 97.96
deep

Excavating trenches minimum 720mm wide for 225mm


diameter pipes including backfilling and disposal of surplus
excavated material (Cont'd)

L1400022 Add or deduct for each stage of 250mm average depth


m 6.80
Trench minimum 600 mm wide and not exceeding 2.00 m
deep commencing from formation level

L1400023 Average 1.50 m deep to falls


m 15.50
L1400024 Add / Deduct for each stage of 200 mm depth m 2.10

Trench minimum 750 mm wide and exceeding 2.00 m and not


exceeding 4.00 m deep commencing from formation level

L1400025 Average 3.00 m deep to falls


m 39.20
L1400026 Add / Deduct for each stage of 200 mm depth
m 2.60
Trench minimum 900 mm wide and exceeding 400 m and not
exceeding 6.00 m deep commencing from formation level

L1400027 Average 5.00 mm deep to falls


m 79.80
L1400028 Add / Deduct for each stage of 200 mm depth
m 3.20

BW-L50
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

Drain excavation (Cont'd)

Beds, haunchings, surrounds and coverings

150mm thick concrete (grade 20) bed under drain pipe


including haunching to half height of pipe carried up and
splayed tangentially and all necessary formwork

L1400029 340mm wide, under 100mm diameter drain pipes m 20.20

L1400030 490mm wide, under 150mm diameter drain pipes m 29.05

L1400031 720mm wide, under 225mm diameter drain pipes m 42.77

Concrete (grade 20) benching finished with 15mm thick


cement and sand (1:3) rendering, the whole finished off at an
angle of 45 degree and trowelled smooth including working
around walls and channels

L1400032 Average 200mm thick m2 37.58

L1400033 m3 105.50
Concrete Grade 25A in bed and haunching or bed and surround to
sewer line including break joints (measured with no adjustment
made for voids)

L1400034 m2 181.35
Granolithic concrete in benching including shaping of inverts,
channels, bends and finishing with 20 mm thick waterproofed
cement and sand (1:3) rendering

Heavy duty ductile iron drain pipe complying with BS 4772


Class K9 with internal lining including spigot and socket
rubber ring joints

L1400035 100mm diameter m 42.66

L1400036 150mm diameter m 61.99

Extra over for fitting

L1400037 100mm diameter bend No 47.74

L1400038 150mm diameter bend No 84.89

L1400039 100 x 100 x 100mm diameter tee No 78.73

L1400040 150 x 150 x 150mm diameter tee No 130.79

BW-L51
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

Vitrified clay drain pipe complying with BS 65 and 540


including spigot and socket rubber ring joints

L1400041 100mm diameter


m 34.13
L1400042 150mm diameter
m 44.82
Extra over for fitting

L1400043 100mm diameter bend


No 32.08
L1400044 150mm diameter bend
No 53.03
L1400045 100 x 100 x 100mm diameter tee
No 43.63
L1400046 150 x 150 x 150mm diameter tee
No 82.19
Gully

Vitrified clay trapped gully with back and side inlets, raising
piece including concrete (grade 15) surround, additional
excavation, disposal of excavated material and jointing outlet
and inlets with rubber rings

L1400047 100mm diameter outlet with 150 x 150mm galvanised iron hinged
grating and frames No 59.94

L1400048 100mm diameter UPVC trapped gully complete with riser, PVC
grating including all connections, excavation, formwork, cutting or No 114.91
coring through concrete floor (if in existing building) and packing
around traps with concrete (Grade 15A) or sand and making good
surround

L1400049 100mm diameter UPVC trapped gully complete with riser, PVC
grating, setting in suspended slabs including all connections, No 110.40
formwork, cutting or coring through concrete floor (if in existing
building) and packing around traps with concrete (Grade 15A) or
sand and making good surround

L1400050 100mm dia salt glazed stoneware gully trap, 150mm x 150mm
galvanised iron or chrome plated hinged grating and frame or No 52.00
150mm dia circular grating to BS 539 including all necessary
inlets, with raising piece where necessary and setting gully on and
surround with concrete grade 15A and all necessary excavation,
formwork, disposal of excavated materials and jointing of drains in
cement and sand (1:1)

L1400051 225mm x 100mm cast iron street gully including connections

L1400052 368mm x 150mm cast iron street gully including connections No 161.00
No 571.00

BW-L52
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)
L1 400000
DRAINAGE WORK (CONT'D)

Inspection chambers/ manholes

Precast concrete inspection chambers / manholes constructed


of 75mm thick lean concrete (grade 15) blinding, 150mm thick
in-situ concrete (grade 20) bases, 215mm thick brickwalls with
20mm cement and sand (1:3) rendering both sides, 200mm
(average) granolithic concrete (grade 20) benching, 150mm
thick in-situ concrete (grade 20) top slabs
reinforced with 13mm diameter mild steel rod reinforcement
finished steel trowelled smooth (cover, main and branch
channel measured separately)

L1400053 900 x 750mm (internal) x 750mm deep No 727.20

L1400054 Add or deduct to/from above item (L1400053) for every stage of No 19.55
25mm in depth of inspection chambers

L1400055 900 x 900mm (internal) x 900mm deep No 1,047.92

L1400056 Add or deduct to/from above item (L1400055) for every stage of No 22.70
25mm in depth of inspection chambers

L1400057 900 x 11250mm (internal) x 900mm deep No 1,098.70

L1400058 Add or deduct to/from above item (L1400057) for every stage of No 23.76
25mm in depth of inspection chambers

L1400059 900 x 1200mm (internal) x 900mm deep No 1,562.33

L1400060 Add or deduct to/from above item (L1400059) for every stage of No 24.30
25mm in depth of inspection chambers

Manholes / inspection chamber covers and frames


Cast iron manhole / inspection chamber covers and frames
complying with SS 30 including bedding frame in cement and
sand (1:3) and sealing cover with grease and sand

L1400060 600 x 450mm, light duty; weighing approximately 37kg No. 81.97

L1400061 710 diameter, medium duty; weighing approximately 114kg No. 242.78
L1400062 No. 420.00
800 x 800mm, double triangular, medium duty; weighing
approximately 205kg

L1400063 600 x 450mm, light duty; weighing approximately 50kg No 100.66

L1400064 710 diameter, heavy duty; weighing approximately 135kg No 261.47

BW-L53
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

Manholes / inspection chamber covers and frames (Cont'd)

Cast iron manhole / inspection chamber covers and frames


complying with SS 30 including bedding frame in cement and
sand (1:3) and sealing cover with grease and sand (Cont'd)

L1400065 800 x 800mm, double triangular, heavy duty; weighing No 471.31


approximately 235kg

L1400066 22kg light duty manhole cover (excluding frame) No 30.00

L1400067 22kg medium duty cast iron manhole cover(excluding frame) No 44.50

L1400068 32kg light duty manhole cover(excluding frame) No 34.00

L1400069 32kg light duty cast iron manhole cover (excluding frame) No 54.70

L1400070 114kg heavy duty cast iron manhole cover and frame including No
setting in cement mortar and sealing cover in grease and fine sand
(excluding frame) including removal off site and making good work 281.00
disturbed

L1400071 710kg heavy duty cast iron manhole cover and frame including
setting in cement mortar and sealing cover in grease and fine sand
(excluding frame) No
225.00
Standard coated ductile cast iron manhole covers and frames
complying with BS 497 including bedding frames in cement
and sand (1:3) mortar and sealing cover in grease sand

L1400072 850 x 850mm No. 355.86

Precast reinforced concrete manhole chamber rings and


cover slab for manholes (rate excludes excavation)

L1400072 1050mm nominal diameter, 0.60m length No 240.62

L1400073 1050mm nominal diameter, 0.90m length No 364.39

L1400074 1050mm nominal diameter, 1 .50m length No 485.57

L1400075 1200mm nominal diameter, 0.60m length No 291.82

L1400076 1200mm nominal diameter, 0.90m length No 445.61

L1400077 1200mm nominal diameter, 1 .50m length No 592.49

BW-L54
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

Manholes / inspection chamber covers and frames (Cont'd)

Precast reinforced concrete manhole chamber rings and


cover slab for manholes (rate excludes excavation) (Cont'd)

L1400078 1.35 m nominal diameter, 1.50 m length No 551.30

L1400079 1.35 m nominal diameter, 0.90 m length No 406.20

L1400080 1.35 m nominal diameter, 0.60 m length No 276.30

L1400081 1.50 m nominal diameter, 1.50 m length No 640.50

L1400082 1.50 m nominal diameter, 0.90 m length No 472.80

L1400083 1.50 m nominal diameter, 0.60 m length No 322.20

L1400084 1.80 m nominal diameter, 1.50 m length No 893.10

L1400085 1.80 m nominal diameter, 0.90 m length No 668.60

L1400086 1.80 m nominal diameter, 0.60 m length No 445.80

Precast reinforced concrete manhole cover slabs with


approved linings

L1400087 1050mm nominal diameter, 150mm thick No 771.44

L1400088 1200mm nominal diameter, 150mm thick No 1,143.94

L1400089 1.05 m normal diameter, 125 mm thick No 535.10

L1400090 1.20 m normal diameter, 125 mm thick No 733.30

L1400091 1.35 m normal diameter, 125 mm thick No 968.70

L1400092 1.50 m normal diameter, 150 mm thick No 1,501.10

L1400093 1.80 m normal diameter, 150 mm thick No 1,802.20


L1400094 m 113.20
150 mm thick concrete (Grade 20) surround to 675 mm diameter
precast concrete access shaft including all formwork

L1400095 Ditto but to 750 mm diameter m 120.00

BW-L55
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

Manholes / inspection chamber covers and frames (Cont'd)

150mm thick concrete (Grade 20) surrounds to precast


concrete chamber rings including all necessary formwork

L1400096 1050mm diameter m 213.19

L1400097 1200mm diameter m 232.74

L1400098 1350mm diameter m 251.36

L1400099 1500mm diameter m 271.47

L1400100 1800 diameter m 293.19

Accessories
L1400101 m 129.60
Aluminium ladder 375mm wide including stringers, rungs, brackets
and stiffeners
L1400102 No 39.00
Aluminium step rungs fabricated of 30mm tubular x 1500mm long
with both ends bent
L1400103 m 86.50
Provide and fix aluminium hand railing 40 mm external diameter,
900 mm high with and including screwed bends, junctions and
flanged bottom

L1400104 Provide and fix aluminium hand hold 30 mm external diameter No 31.80
1.50 m long with both ends bent
L1400105 m 49.75
Provide and fix aluminium safety link chain including hooks and
end rings

Note

Manholes or inspection chambers which cannot be resonably pro-


rated against the schedule above shall be rated in detail

British Standard tested salt glazed stoneware channels to BS


65 as specified in bottom of manholes or inspection
chambers

L1400106 100mm diameter straight channels m 6.05

L1400107 150mm diameter straight channels m 8.42

L1400108 225mm diameter straight channels m 13.28

L1400109 100mm diameter channel bends No 5.62


BW-L56
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 400000 DRAINAGE WORK (CONT'D)

British Standard tested salt glazed stoneware channels to BS


65 as specified in bottom of manholes or inspection
chambers (Cont'd)

L1400110 150mm diameter channel bends No 7.13

L1400111 225mm diameter channel bends No 16.63

L1400112 100mm to 150mm diameter tapered straight main channels m 16.63

L1400113 100mm to 150mm diameter tapered channel bends m 18.79


L1400114 m 21.17
150mm to 225mm diameter tapered straight channels or taper
channel bends

L1400115 100mm on 150mm diameter channel junctions m 12.10

L1400116 100mm on 225mm diameter channel junctions m 30.35

L1400117 150mm on 150mm diameter channel junctions m 13.61


L1400118 150mm on 225mm diameter channel junctions m 33.59

L1 500000 GREASE, PETROL AND SILT INTERCEPTOR

Standard grease interceptors as per Drawing No.


ENV/SEW/76/82-4 comprising of 1050mm diameter precast
chamber rings, aluminium alloy strainers, buckets, aluminium
alloy chequered plate covers welded to grating etc (covers
measured separately)

L1500001 Not exceeding 1.50 m deep No 4,752.00

L1500002 Exceeding 1.50 m and not exceeding 2.00 m No 5,140.80

L1500003 Exceeding 2.00 m and not exceeding 2.50 m No 5,529.60

L1500004 Exceeding 2.50 m and not exceeding 3.00 m No 5,907.60

L1500005 Exceeding 3.00 m and not exceeding 3.50 m No 6,285.60

L1500006 Exceeding 3.50 m and not exceeding 4.00 m No 6,696.00

BW-L57
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 500000
GREASE, PETROL AND SILT INTERCEPTOR (CONT'D)

Standard grease interceptor as per Drawing No.


ENV/SEW/76/82-3B comprising of 1800mm diameter precast
chamber rings, aluminium alloy strainers, buckets, etc of
depth not exceeding 1500mm (covers measured separately)

L1 500007 Not exceeding 1.50 m deep No 6,912.00

L1500008 Exceeding 1.50 m and not exceeding 2.00 m No 7,516.80

L1500009 Exceeding 2.00 m and not exceeding 2.50 m No 8,100.00

L1500010 Exceeding 2.50 m and not exceeding 3.00 m No 8,672.40

L150001 1 Exceeding 3.00 m and not exceeding 3.50 m No 9,244.80

L1500012 Exceeding 3.50 m and not exceeding 4.00 m No 9,849.60

Grease interceptor covers

L1500013 1800mm diameter x 15mm thick glass fibre reinforced plastic No 1,512.00
(GRP) cover complete

L1500014 1800mm diameter x 15mm thick glass fibre reinforced plastic No 2,538.00
(GRP) cover with 10mm thick mild steel chequered plate with
angles skeleton frames with bituminous painted on both sides
L1500015 Approved 1800mm diameter chequered aluminium grease 3-piece No 1,657.80
type trap covers including locking and all necessary accessories

L1500016 Approved 1800mm diameter chequered aluminium grease 9-piece No. 2,052.00
type trap covers including locking and all necessary accessories

L1 600000 BASINS
Note :
Extra piping for the following sanitary fittings shall be measured
separately

Glazed vitreous china wash hand basins complete with


chromium plated waste and chain with plug, chromium plated
bottle traps and brackets to wall, making good work
disturbed and making connections and adjustments to piping

L1600001 Wall hung type (white colour) No 159.30

BW-L58
L : PLUMBING
L1600002 Wall hung type (standard colour) No 171.29

BW-L59
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 600000 BASINS (CONT'D)

Note (Cont'd):
Extra piping for the following sanitary fittings shall be
measured separately

Glazed vitreous china wash hand basins complete with


chromium plated waste and chain with plug, chromium plated
bottle traps and brackets to w all, making good w ork
disturbed and making connections and adjustments to piping
(Cont'd)

L1600003 Under-counter type (white colour) No 163.40

L1600004 Under-counter type (standard colour) No 175.72

L1 600005 Overcounter type wash basin No 121.00


Stainless steel basin overall size 550 x 450mm with weir overflow No 191.00
complete with painted steel or hot dipped galvanised brackets ,
38mm dia chromium plated brass waste and chain

L1700000 SINKS

Note :
Extra piping for the following sanitary fittings shall be
measured separately

White enamelled fire clay sinks complete with chromium


plated waste fittings and chains with plugs, chromium plated
bottle traps and brackets to w all, making good w ork
disturbed and making connections and adjustments to piping

L1700001 610 x 472 x 162mm deep service sinks No 554.90

L1700002 760 x 472 x 165mm deep service sinks No 573.26

0.70mm (22 SWG) stainless steel sinks complying with SS 40


complete with 38mm diameter chromium plated waste fittings
and chains with plugs, chromium plated bottle traps and
brackets to walls, making good work disturbed and making
connections and adjustments to piping

L1 700003 Single bowl, single drainer sink overall size 1,070 mm x 450 mm x No 200.85
150 mm deep

L1700004 Ditto 1,070 mm x 530 mm x 150 mm deep No 211.15

BW-L60
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1700000 SINKS (CONT'D)

Note (Cont'd):
Extra piping for the following sanitary fittings shall be
measured separately

0.70mm (22 SWG) stainless steel sinks complying with SS 40


complete with 38mm diameter chromium plated waste fittings
and chains with plugs, chromium plated bottle traps and
brackets to walls, making good work disturbed and making
connections and adjustments to piping (Cont'd)

L1700005 Single bowl, double drainer sink overall size 1,200 mm x 450 mm No 208.80
x 150 mm deep

L1 700006 Ditto 1,200 mm x 530 mm x 150 mm deep No 221.40

L1700007 Ditto 1,300 mm x 530 mm x 150 mm deep No 243.15

L1700008 Ditto 1,350 mm x 450 mm x 150 mm deep No 225.45

L1700009 Ditto 1,500 mm x 450 mm x 150 mm deep No 232.05

L1 700010 Ditto 1,500 mm x 530 mm x 150 mm deep No 248.40


L1 700011 No 280.85
Double bowl, double drainer sink overall size 1,500 mm x 450 mm
x 150 mm deep

L1700012 Ditto 1,524 mm x 530 mm x 150 mm deep No 313.05

L1700013 Ditto 1,800 mm x 450 mm x 150 mm deep No 306.75

L1700014 Ditto 1,829 mm x 530 mm x 150 mm deep No 335.30

L1700015 Single bowl, single drainer sink overall size 762 mm x 500 mmx No 131.40
165 mm deep

L1 700016 Ditto but overall size 800 mm x 500 mmx 165 mm deep No 131.40

L1700017 Single bowl, single drainer sinks 900 x 500 x 165mm deep No 178.85

L1700018 Single bowl, single drainer sinks 1000 x 500 x 165mm deep No 192.78

L1 700019 Ditto but overall size 1,067 mm x 533 mmx 165 mm deep No 208.20

L1700020 Single bowl, single drainer sinks 1500 x 500 x 165mm deep No 238.57
L1700021 No 419.47
Double bowl, double drainer sinks 1500 x 500 x 165mm deep (lay-
on type)

BW-L61
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1700000 SINKS (CONT'D)

Note (Cont'd):
Extra piping for the following sanitary fittings shall be
measured separately

0.70mm (22 SWG) stainless steel sinks complying with SS 40


complete with 38mm diameter chromium plated waste fittings
and chains with plugs, chromium plated bottle traps and
brackets to walls, making good work disturbed and making
connections and adjustments to piping (Cont'd)

L1700022 Double bowl, double drainer sinks 1800 x 500 x 165mm deep (lay- No 456.51
on type)

No 114.75
L1700023 Single bowl sink overall size 406 mm x 355 mm x 180 mm deep
No 126.00
L1700024 750mm x 450mm x 170mm single bowl, stainless steel sink, single
drainer sink complete with 40mm dia waste fittings, chromium
plated chain and plug, and a set of hot dipped galvanised brackets

L1700025 900mm x 450mm x 170mm single bowl, stainless steel sink, single No 131.00
drainer sink complete with 40mm dia waste fittings, chromium
plated chain and plug, and a set of hot dipped galvanised brackets

L1700026 1050mm x 450mm x 170mm single bowl stainless steel sink, No 135.00
single drainer sink complete with 40mm dia waste fittings,
chromium plated chain and plug, and a set of hot dipped
galvanised brackets

L1700027 1050mm x 525mm x 170mm single bowl stainless steel sink, No 153.00
single drainer sink complete with 40mm dia waste fittings,
chromium plated chain and plug, and a set of hot dipped
galvanised brackets

L1700028 1000mm x 500mm x 170mm single bowl , stainless steel sink, No 135.00
single drainer sink complete with 40mm dia waste fittings,
chromium plated chain and plug, and a set of hot dipped
galvanised brackets

L1700029 1500mm x 500mm x 170mm single bowl stainless steel sink, No 157.00
single drainer sink complete with 40mm dia waste fittings,
chromium plated chain and plug, and a set of hot dipped
galvanised brackets

BW-L62
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1700000 SINKS (CONT'D)

Note (Cont'd):
Extra piping for the following sanitary fittings shall be
measured separately

0.70mm (22 SWG) stainless steel sinks complying with SS 40


complete with 38mm diameter chromium plated waste fittings
and chains with plugs, chromium plated bottle traps and
brackets to walls, making good work disturbed and making
connections and adjustments to piping (Cont'd)

L1700030 1500mm x 500mm x 170mm double bowl , stainless steel sink, No 225.00
single drainer sink complete with 40mm dia waste fittings,
chromium plated chain and plug, and a set of hot dipped
galvanised brackets

L1700031 1800mm x 500mm x 170mm double bowl stainless steel sink, No 270.00
single drainer sink complete with 40mm dia waste fittings,
chromium plated chain and plug, and a set of hot dipped
galvanised brackets

No 126.00
L1700032 305mm x 305mm x 178mm white glazed laboratory sinks,
complete with weir overflow, 38mm dia plug and chain, 40mm dia
waste fittings and a set of hot dipped galvanized brackets including
adjustment, connections to existing pipes and fittings, otherwise
stated but extra piping to sanitary fittings will be measured
separately

L1700033 360mm x 360mm x 255mm white glazed laboratory sinks, No 96.00


complete with weir overflow, 38mm dia plug and chain, 40mm dia
waste fittings and a set of hot dipped galvanized brackets including
adjustment, connections to existing pipes and fittings, otherwise
stated but extra piping to sanitary fittings will be measured
separately

L1700034 560mm x 360mm x 255mm white glazed laboratory sinks, No 141.00


complete with weir overflow, 38mm dia plug and chain, 40mm dia
waste fittings and a set of hot dipped galvanized brackets including
adjustment, connections to existing pipes and fittings, otherwise
stated but extra piping to sanitary fittings will be measured
separately

L1700035 700(L) x 380(W) x 270(D)mm phenol resistance epoxy laboratory set 400.00
sink and accessories. It shall be underhung sink type and include
all waste outlets, overflows and other compatible accessories in
polypropylene

BW-L63
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 800000 TROUGHS

Note :
Extra piping to sanitary fittings shall be measured separately

1.22mm (18 SWG) stainless steel trough (grade 304) complete


with chromium plated waste fittings and chains with plugs,
chromium plated bottle traps and brackets to wall, making
go o d wor k di st urb ed and makin g co nn ecti on s an d
adjustments to piping

L1800001 1200 x 500 x 228mm deep stainless steel trough No 841.10

L1800002 1350 x 500 x 228mm deep stainless steel trough No 903.96

L1800003 1372 x 500 x 228mm deep stainless steel trough No 914.76

L1 800004 1800 x 500 x 228mm deep stainless steel trough No 1,002.24

L1 800005 2400 x 500 x 228mm deep stainless steel trough No 1,213.92

L1 800006 3000 x 500 x 228mm deep stainless steel trough No 1,470.96

L1 800007 3400 x 500 x 228mm deep stainless steel trough No 1,661.04

L1 800008 Custom made 700 x 650 x 300mm deep stainless steel trough No 421.20

L1800009 Custom made 800 x 800 x 300mm deep stainless steel trough No 626.40

L1800010 Custom made 915 x 750 x 406mm deep stainless steel trough No 807.30

L1 800011 1500mm x 300mm x 228mm deep stainless steel trough No 871.88

Polythene bench troughs complete with waste fittings and


chains with plugs, bottle traps and brackets to wall, making
go o d wor k di st urb ed and makin g co nn ecti on s an d
adjustments to piping

L1800012 140 x 140mm deep polythene bench troughs m 106.92

BW-L64
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 900000 WATER CLOSETS

Note :
Extra piping for the following sanitary shall be measured
separately

Squatting water closets


L1900001 No 161.45
Approved white glazed vitreous china squatting water closets
complete with 'S' or 'P' trap and cleaning eyes (flushing cisterns
measured separately)

L1900002 No 170.00
Approved white glazed vitreous china squatting water closets
complete with 'S' or 'P' trap, cleaning eyes, flush pipes and tread
plates (flushing cisterns measured separately)

Pedestal water closets

Vitreous china close - coupled washdown water closet suite


complying with SS 205 complete with 'S' or 'P' traps,
matching plastic hinged seat and covers

L1900003 Pedestal close-coupled washdown type (white colour) No 270.90

L1900004 Pedestal close-coupled washdown type (standard colour) No 296.10

Approved vitreous china wall hung washdown water closet


suite complying with SS 205 complete with stainless steel
brackets fixing with 'P' traps, matching plastic hinged seat
and covers

L1900005 Wall hung type (white colour) No 381.67

L1900006 Wall hung type (standard colour) No 410.29

Water closet seats and covers

Approved heavy duty hinged seats and covers inclusive of


brackets, bolts and nuts

L1900007 Children's pedestal water closet seats and covers No 28.62

L1900008 Pedestal water closet seats and covers (white colour) No 14.15

L1900009 Pedestal water closet seats and covers (standard colour) No 15.66

BW-L65
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L1 900000 WATER CLOSETS (CONT'D)

Water closet seats and covers (Cont'd)

Approved 4.5 litres cisterns for water closets or urinals


including a set of stainless steel or painted brackets and all
necessary covers, feeding pipes, valveless syphon, outlets,
overflows, ball valves, floats and handles

L1 900010 PVC flushing cisterns (white colour) No 51.84

L1900011 Vitreous china flushing cisterns (white colour) No 135.00

L1900012 Vitreous china flushing cisterns (standard colour) No 158.76

Flush pipes
L1900013 No 14.48
38mm diameter galvanised steel flush pipe for high level water
closet cistern including all connections and painting with two coats
of enamel paints
L1900014 No 8.75
38mm diameter approved UPVC flush pipe for high level cisterns
including all connections
L1900015 No 10.69
38mm diameter galvanised steel flush pipe including rubber cone
for low level cisterns

L1900016 30mm diameter approved UPVC flush pipe including rubber cone No 8.53
for low level cisterns

L2000000 URINALS

Note :
Extra piping for the following sanitary shall be measured
separately

Approve d vi tre ous c hi na uri nal bow l w ith back i nle t


complying with integral strainer waste, chromium plated
bottle traps and brackets to walls

L2000001 Wall hung urinal bowls No 249.90

18/8 stainless steel urinals 1060mm high x 320mm wide in one


piece assembly, complete with end return, channel, 80mm
diameter domical outlet fitting, stainless steel flush pipe
(concealed) and spreader nozzle, etc. including all necessary
connections and adjustments (flushing cisterns measured
separately)

L2000002 600mm long single stall type No 574.78

BW-L66
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)
L2000000
URINALS (CONT'D)

Note (Cont'd):
Extra piping for the following sanitary shall be measured
separately

18/8 stainless steel urinals 1060mm high x 320mm wide in one


piece assembly, complete with end return, channel, 80mm
diameter domical outlet fitting, stainless steel flush pipe
(concealed) and spreader nozzle, etc. including all necessary
connections and adjustments (flushing cisterns measured
separately) (Cont'd)

L2000003 1200mm long slab type No 784.08

L2000004 1800mm long slab type No 1,084.32

L2000005 2400mm long slab type No 1,358.64

L2000006 3000mm long slab type No 1,620.00

L2000007 3600mm long slab type No 1,922.29


L2000008 4200mm long slab type No 2,181.60

L2100000 TAPS AND VALVES AND CONSTANT FLOW REGULAR

Chromium plated taps including connections

L2100001 13mm pillar taps No 35.32

L2100002 20mm pillar taps No 38.14

L2100003 13mm lever type pillar taps No 86.94

L2100004 13mm wall mounted bib taps No 34.02

L2100005 13mm dia wall bib tap c/w allen key No 16.00

L2100006 15mm brass bib-tap c/w hose nozzle No 9.00

L2100007 15mm chromium coated bib- tap c/w hose nozzle No 9.00
L2100008 No 12.00
15mm chromium coated bib-tap c/w hose nozzle with padlock
device

L2100009 13mm wall mounted bib taps with goose-neck swivel spout No 74.63

L2100010 13mm dia chromium plated single swanneck tap No 25.00

L210001 1 Approved self closing delayed action taps No 80.00

BW-L67
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L2100000 TAPS AND VALVES AND CONSTANT FLOW REGULAR


(CONT'D)

Chromium plated taps including connections (Cont'd)


L2100012 No 77.54
13mm chromium plated combined supply fitting with elbow action
levers, antisplash nozzle and extended inlets

L2100013 20mm - ditto No 50.00


L2100014 No 15.00
Constant flow regulator with 6, 8 or 12 litres /mins including
connection, adjustment to pipes and fittings.

L2100015 No 10.00
Constant flow regulator with 2 litres/mins including connection,
adjustment to pipes and fittings.

L21 00016 15mm stainless steel coated lever tap c/w hose nozzle No 9.00
L2100017 Supply and install or replace 20mm dia brass tap with hose nozzle No 24.00

L2100018 Two-Way Taps No 16.50

L2100019 Handicapped tap c/w Hose coupling No 34.00

L2100020 Brass hose connector to tap No 4.00

L2100021 Plug nut No 4.00


L2100022 No 180.00
13mm dia chromium plated hot and cold basin mixer tap complete
with pop-up waste fitting

L2100023 20mm dia - Ditto No 90.00


L2100024 No 110.00
13mm dia chromium plated hot and cold pillar or wall type tap with
adjustable spout

L2100025 No 42.00
13mm dia chromium plated push button pillar tap including
connection and adjustment

13mm laboratory fittings (oxidised) with swanneck, anti-


splash nozzle and desk flanges

L2100026 One way type No 87.80

L2100027 Two way type No 119.25

L2100028 Three way type No 125.82

BW-L68
L : PLUMBING
L2100029 Approved 13mm diameter approved constant flow regulator No 8.75

L2100030 13mm diameter mini ball valve No 5.40

BW-L69
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L2200000 FLUSH VALVES

Approved flush valves complete with back check, valves, stop


valves, vacuum breakers and stainless steel flush pipes

L2200001 Exposed type for water closet pans No 255.10

L2200002 Push button concealed type for water closet pans No 351.11

L2200003 Exposed flush type for urinals No 98.93

L2200004 Push button concealed type for urinals No 220.00

L2200005 Battery operated exposed sensor type for urinal No 685.80

L2200006 Exposed sensor type for water closets No 410.40


L2200007 Concealed sensor type for water closets No 518.40

L2300000 SOAP HOLDERS

150 x 150mm vitreous china semi-recessed or recessed type


soap holders built into existing or new wall including cutting
out wall tiles and making good works disturbed

L2300001 150 x 150mm soap holders (white colour) No 22.68


L2300002 150 x 150mm soap holders (standard colour) No 23.87

L2400000 TOILET ROLL HOLDERS

Semi-recessed or recessed type toilet paper holders built into


existing or new wall including cutting out wall tiles and
making good works disturbed

L2400001 150 x 150mm vitreous china toilet paper holders (white colour) No 22.68

L2400002 150 x 150mm vitreous china toilet paper holder (standard colour) No 23.87

Toilet paper holders screwed or plugged to walls


L2400003 No 30.67
Approved chromium plated toilet paper holders with locking
devices
L2400004 No 25.60
Approved recessed chromium plated toilet paper holder 300 x 160
x 55mm

L2400005 No 15.34
Approved surface-mounted chromium plated toilet paper holder
with plastic rollers

BW-L70
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L2400000 TOILET ROLL HOLDERS (CONT'D)

Toilet paper holders screwed or plugged to walls (Cont'd)


L2400006 No. 9.00
Approved surface-mounted plastic toilet paper holder with plastic
rollers
L2400007 No 20.41
Approved surface-mounted stainless steel single roller toilet paper
holders

L2400008 273 x 273 x 120mm stainless steel jumbo size toilet paper No 65.88
dispenser with key

L2500000 TOWEL RAILS

16mm diameter towel rails complete with two brackets


including plugging and screwing to walls

L2500001 600mm long chromium plated brass towel rails No 25.27


L2500002 532mm long approved plastic towel rails No 19.44

L2600000 SOAP DISPENSERS

L2600001 Stainless steel surface mounted vertical soap dispensers No 93.42


L2600002 Stainless steel deck mounted liquid soap dispensers No 93.96

L2700000 WASTE RECEPTACLES

Waste receptacles including plugging and screwing to walls

L2700001 460 x 330 x 125mm stainless steel surface mounted waste No 156.81
receptacles

L2800000 HAND DRYERS

Hand dryers including plugging and screwing to walls

L2800001 Sensor auto hand dryer No 222.70


L2800002 No 230.00
Supply and deliver solomon SHD-1100 automatic hand dryer,
Size: 283 x 220 x 158mm

L2800003 No 320.00
Supply and deliver EM "Air Steam 2000" automatic hand dryer,
Size: 270 x 265 x 141mm
BW-L71
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L2800000 HAND DRYERS (CONT'D)

Hand dryers including plugging and screwing to walls


(Cont'd)
L2800004 Supply and deliver MEDICLINIC M88A junior automatic hand dryer No 180.00

L2800005 Supply and deliver Initial (Applause) hand dryer No 380.00

L2900000 GRAB BARS

L2900001 Stainless steel grab bars fabricated of 38mm tubular consisting of No 335.34
L-shaped bar 1200 x 840mm and two straight bars 650mm in
length
L2900002 Stainless steel grab bars fabricated of 38mm tubular and No 318.60
consisting of two V shaped bar 700 x 700mm (135 degree) and
one straight bar 650mm in length

L3000000 SHOWER FITTINGS

L3000001 No 29.50
Approved fixed shower head with ball swivel arm and flanges
including connections and adjustments to piping

L3000002 No 109.30
Approved chromium plated spray shower mixers with sliding rail,
brackets and telephone shower attachment

L3000003 no 24.00
Approved plastic shower spray complete with sliding rail , brackets
and telephone shower attached
L3000004 no 35.00
Approved adjustable telephone shower set including brackets and
flexible rubber tubing not exceeding 1 .2m
L3000005 no 9.50
Approved stainless steel coated sliding shower head holder
including making good work disturbed and removal off site

L3000006 Approved plastic shower holder for shower rail no 17.00

L3000007 Approved chrome plated wall plate elbow for shower mixer 15.00

L3000008 Approved plastic telephone shower head no 8.00


L3000009 no 10.00
Approved chrome plated telephone head shower holder on wall or
mixer tap

L3000010 no 33.00
Approved chrome plated shower head including making good work
disturbed and removal off site.(tiles measure separately)

BW-L72
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L3000000 SHOWER FITTINGS (CONT'D)

L300001 1 Approved spray gun head only complete with 2 nos. of washers
and connectors including making good work disturbed and no 7.50
removal off site

L3000012 Approved spray gun head only complete with 2 nos. of washers
and connectors including making good work disturbed and no 10.00
removal off site

L3000013 Approved spray gun set complete with 2 nos. of washers and
connectors, flexible tube including making good work disturbed no 10.00
and removal off site (New/ Replacement)

L3000014 Approved spray gun set complete with 2 nos. of washers and
connectors, stainless steel flexible tube including making good no 17.00
work disturbed and removal off site (New/ Replacement)

L3000015 Approved chrome plated shower arm 0.5 inch dia x 5 inch length
complete with flange no 20.00

L3000016 Supply and install or replace 50mm dia chromium plated plastic
adjustable shower rose no 12.00

L3000017 Supply and install or replace 100mm dia galvanised iron shower
hose no 11.00

L3000018 Supply and install or replace 100mm dia swivel chromium plated
brass shower hose no 42.00

L3000019 Supply and install or replace 50mm dia chromium plated brass
adjustable shower rose no 19.00

L3000020 Supply and install Single-lever mixer for shower, wall mtg including
making good work disturbed and removal off site.(tiles measure no 80.00
separately)

L3000021 Supply and instal or replace exposed or concealed delay action


stop-cock for shower including making good work disturbed and no 63.00
removal off site.

L31 00000 LABORATORY FITTINGS

L3100001 Eye showers complete with built-in flow fix regulator, ball valves and
No 478.22
fixing accessories

L3100002 Emergency drench shower complete with discharge pipes, shower


rose, integrated stopcock and fixing accessories No 398.74

BW-L73
L : PLUMBING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

L3200000 WATER COOLER

L3200001 Supplying only wall mounted lead-free with filter water coolers in
stainless steel casting/body having 30 litres per hour capacity No 765.07
complete with compressor, mould pressed stainless steel splash
resistant basin, chromium plated bubblers with mouth guard, self-
closing push button and steam regulator

L3200002 Supplying only wall mounted / floor standing lead-free with filter
hot and cold water dispenser in stainless steel casting/body having No 959.90
15 litres per hour for cold and 20 litres per hour for hot capacity
complete with compressor, mould pressed stainless steel splash
resistant basin, chromium plated bubblers with mouth guard, self-
closing push button and steam regulator

L3200003 Fixing of water coolers / dispensers complete with piping not


exceeding 3.00m No 62.10

L3200004 Add to above item (L3200003) for additional piping exceeding 3m


m 24.84
L3300000 CULTURE MARBLE VANITY TOPS

12mm thick appr

oved culture marble vanity tops consisting of integrated basins,


100mm high backsplash, 200mm front apron mounted on
galvanised mild steel brackets bolted to walls including sealing
joints between vanity top and walls with matching sealants
(measured area on plan)

Vanity tops m2 434.70


L3300001 Vanity Top (Not exceeding 1 .00m length) m2 792.00

L3300002 Vanity Top (Exceeding 1 .00m length) m2 702.00

L3400000 SPRINKLER SYSTEM

Hockey Field
Job 17,500.00
L3400001 Supply and install new sprinkler system to synthetic field complete
with water tanks, pumps, sprinkler heads, pipings and all other
necessary accessories and works etc

L3400002 Replace existing damaged / missing sprinkler head and complete No. 4,500.00
with all necessary installation and accessories etc

BW-L74
L : PLUMBING
ITEM NO. DESCRIPTION UNIT RATE
(S$)

SUB SECTION L: PLUMBING


L35 00000 MISCELLANEOUS

L35 00001 To supply labour, material, transport and equipment service Job 60.00
existing WC or urinal sensor flush valve

L35 00002 To supply all materials, labour, transport to replace or install Job 150.00
adaptor for WC or urinal flush valve

L35 00003 To supply all labour, materials, transport and equipment to Job 200.00
install WC/ urinal sensor eye

L35 00004 To supply all materials, labour, transport to replace or insall Job 100.00
piston

L35 00005 To supply all materials, labour, transport to replace push Job 120.00
button for flush valve

L35 00006 To supply all materials, labour, transport to replace or install Job 65.00
micro switch

L35 00007 To supply labour, material, transport and equipment to install Job 150.00
solenoid valve

L35 00008 To supply all materials, labour, transport to replace or install Job 60.00
hydraulic fitting – Elbow

L35 00009 To supply all materials, labour, transport to replace or install Job 80.00
hydraulic fitting – Tee

L35 00010 To supply all materials, labour and transport to replace or Job 100.00
install hydraulic valve

L35 00011 To supply all materials, labour, transport to replace or install Job 60.00
sensor battery / Lithium battery

L35 00012 To supply all materials, labour, transport to replace or install Job 130.00
WC or urinal face plate

L35 00013 To supply all materials, labour, transport to replace or install Job 30.00
hydraulic tube

L35 00014 Take out existing and fix back existing urinal bowl with new Job 180.00
sealant

L35 00015 Take out existing back to wall WC, check for leaking, repair Job 220.00
or replace all necessary part to stop leak and fix back
existing WC

BW-L75
L : PLUMBING
ITEM NO. DESCRIPTION UNIT RATE
(S$)

L35 00016 To supply and replace battery operated concealed sensor Job 480.00
type for urinal brand: AWS/ Gobal (WELS Mark)

L35 00017 To supply confined space safety assessor to check, test and Job 500.00
to approve permit to entry and work in water tank c/w blower
and ducting

L35 00018 Stainless steel mesh for water tank Job 20.00

BW-L76
SECTION M: GLAZING
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M100000 DEMOLITION / ALTERATIONS

Taking out existing glass or louvres either whole or broken, in


casements, doors, frames, vents, cart away and preparing to
receive new

M100001 Taking out existing glass m2 3.05


M100002 No 0.40
Taking out existing glass louvres (any size) as directed or set
aside for re-use
M100003 m2 9.55
Refixing existing glass to wood or metal frames with and including
glazing beads.

M100004 Ditto including cutting to required size m2 12.60


M100005 Refixing existing glass louvres (any size) to wood or metal frames No 0.60

Labour for cutting in glazing and polishing edges

M100006 Cutting to required sizes m 3.24


M100007 No 7.35
Cutting holes to form square openings irrespective of sizes to
receive fittings
M100008 No 9.05
Cutting holes to form circular openings irrespective of sizes to
receive fittings

M1 00009 Labour for polishing edges m 1.25


M100010 m2 3.30
Removal of existing solar protective film including cleaning of the
glass panels

M100011 no 7.70
Supply labour and equipment to cut existing table glass panel (any
size)

Mirrors
M100012 No 1.60
Taking out existing mirrors, including necessary plywood backing,
removing off site and making good works disturbed
M100013 No 4.90
Taking out existing chromium plated brass mirror screws and
refixing including replacing with new mirror screws including
plugging

M100014 U' shaped aluminium frames to mirror m 6.25

BW-M1
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M100000 DEMOLITION / ALTERATIONS (CONT'D)

Glass shelf (Cont'd)


M100015 No 1.60
Taking out glass shelf and brackets, removing off site and making
good works disturbed
M100016 No 1.30
Taking out existing chromium plated brackets, refixing with new
chromium plated screws and making good works disturbed
M100017 No 5.40
600 x 125 x 6mm thick glass shelf with edges around fixed on
existing brackets

M100018 Chromium plated galvanised iron brackets for glass shelves, in Pair 6.80
replacement

M200000 STANDARD GLASS IN PANES

Clear float glass to metal or wood frames

M200001 3mm thick m2 29.30

M200002 4mm thick m2 31.30

M200003 5mm thick m2 32.83

M200004 6mm thick m2 36.35

M200005 8mm thick m2 57.35

M200006 10mm thick m2 110.75

M200007 12mm thick m2 180.65

Tinted float glass to metal or wood frames

M200008 5mm thick m2 40.08

M200009 6mm thick m2 47.13

M200010 8mm thick m2 93.70

M200011 10mm thick m2 194.75

M200012 12mm thick m2 230.70

Frosted glass to metal or wood frames

M200013 4mm thick m2 52.30

M200014 5mm thick m2 43.70

BW-M2
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M200000 STANDARD GLASS IN PANES (CONT'D)

Frosted glass to metal or wood frames (Cont'd)

M200015 6mm thick m2 47.15

M200016 8mm thick m2 79.70

M200017 10mm thick m2 128.20

M200018 12mm thick m2 146.02

Obscured glass to metal or wood frames

M200019 4mm thick m2 35.90

M200020 5mm thick m2 39.95

M200021 6mm thick m2 44.33

Clear tempered float glass to metal or wood frames

M200022 6mm thick m2 99.47

M200023 8mm thick m2 150.25

M200024 10mm thick m2 168.26

M200025 12mm thick m2 209.70

Tinted tempered float glass to metal or wood frames

M200026 6mm thick m2 113.10

M200027 8mm thick m2 177.67

M200028 10mm thick m2 216.38

M200029 12mm thick m2 247.26

Clear laminated float glass to metal or wood frames

M200030 6mm thick m2 105.00

M200031 8mm thick m2 156.10

M200032 10mm thick m2 175.90

M200033 12mm thick m2 243.80

BW-M3
M : GLAZING
ITEM NO. DESCRIPTION UNIT RATE
(S$)

M200000 STANDARD GLASS IN PANES (CONT'D)

Figured wired glass to metal or wood frames

M200034 5.5mm thick m2 33.80

M200035 6mm thick m2 44.30

Georgian wired polished glass to metal or wood frames

M200036 6mm thick m2 139.80

Tinted laminated float glass to metal or wood frames

M200037 6mm thick m2 113.80

M200038 8mm thick m2 149.78

M200039 10mm thick m2 184.00

M200040 12mm thick m2 210.30

Tinted heat strengthened laminated float glass

M200041 10mm m2 400.00


M200042 12mm m2 450.00

M300000 STANDARD GLASS IN LOUVRES

Clear float glass louvres with ground and polished edges and
with ends housed in grooves of timber frames or fixed to
metal clips

M300001 100mm wide x 5mm thick m 4.10

M300002 150mm wide x 5mm thick m 5.25

M300003 Add or deduct for each 25mm in width for item (M300001) and m 0.60
(M300002)

M300004 100mm wide x 6mm thick m 4.43

M300005 150mm wide x 6mm thick m 5.83

M300006 Add or deduct for each 25mm in width for item (M300004) and m 0.75
(M300005)

M300007 100mm wide x 4mm thick m 3.50

M300008 150mm wide x 4mm thick m 5.40

M300009 Add or deduct for each 25mm in width m 0.90

BW-M4
M : GLAZING

BW-M5
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M300000 STANDARD GLASS IN LOUVRES (CONT'D)

Clear float glass louvres with ground and polished edges and
with ends housed in grooves of timber frames or fixed to
metal clips (Cont'd)

M300010 100mm wide x 8mm thick M30001 m 6.60


1 150mm wide x 8mm thick M30001 2 Add or m 9.90
deduct for each 25mm in width
m 1.70

M300013 100mm wide x 10mm thick M300014 m 12.70


150mm wide x 10mm thick M300015 Add or
m 19.00
deduct for each 25mm in width
m 2.50

m 19.40
M300016 100mm wide x 12mm thick M300017
150mm wide x 12mm thick M300018 Add or m 29.20

deduct for each 25mm in width m 4.80

Tinted float glass louvres with ground and polished edges


and with ends housed in grooves of timber frames or fixed to
metal clips

M300019 100mm wide x 5mm thick m 4.42


M300020 150mm wide x 5mm thick m 5.83
m 0.80
M300021 Add or deduct for each 25mm in width for item (M300019) and
(M300020)

M300022 100mm wide x 6mm thick m 5.72


M300023 150mm wide x 6mm thick
m 7.55
M300024 Add or deduct for each 25mm in width for item (M300022) and m 1.10
(M300023)
M300025 100mm wide x 8mm thick
m 7.90
M300026 150mm wide x 8mm thick
m 11.80
M300027 Add or deduct for each 25mm in width
M300028 100mm wide x 10mm thick m 2.00

M300029 150mm wide x 10mm thick m 22.40


M300030 Add or deduct for each 25mm in width m 33.70

m 5.60

BW-M6
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M300000 STANDARD GLASS IN LOUVRES (CONT'D)

Tinted float glass louvres with ground and polished edges


and with ends housed in grooves of timber frames or fixed to
metal clips (Cont'd)

M300031 100mm wide x 12mm thick m 26.80

M300032 150mm wide x 12mm thick m 40.30

M300033 Add or deduct for each 25mm in width m 6.70

Frosted glass louvres with ground and polished edges and


with ends housed in grooves of timber frames or fixed to
metal clips

M300034 100mm wide x 5mm thick m 4.97

M300035 150mm wide x 5mm thick m 6.55

M300036 Add or deduct for each 25mm in width for item (M300034) and m 0.95
(M300035)

M300037 100mm wide x 6mm thick m 5.29

M300038 150mm wide x 6mm thick m 7.10

M300039 Add or deduct for each 25mm in width for item (M300037) and m 1.00
(M300038)

M300040 100mm wide x 4mm thick m 5.20

M300041 150mm wide x 4mm thick m 7.70

M300042 Add or deduct for each 25mm in width m 1.30

Obscured glass louvres with ground and polished edges and


with ends housed in grooved in grooves of timber frames or
fixed to metal clips

M300043 100mm wide x 4mm thick m 4.30

M300044 150mm wide x 4mm thick m 6.40

M300045 Add or deduct for each 25mm in width m 1.10

M300046 100mm wide x 5mm thick m 4.97

M300047 150mm wide x 5mm thick m 7.34

M300048 Add or deduct for each 25mm in width for item (M300046) and m 0.86
(M300047)

BW-M7
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M300000 STANDARD GLASS IN LOUVRES (CONT'D)

Obscured glass louvres with ground and polished edges and


with ends housed in grooved in grooves of timber frames or
fixed to metal clips (Cont'd)

M300049 100mm wide x 6mm thick m 6.16

M300050 150mm wide x 6mm thick m 9.18

M300051 Add or deduct for each 25mm in width for item (M300049) and m 1.08
(M300050)

Georgian wire polished glass louvres with ground and


polished edges and with ends housed in grooved in grooves
of timber frames or fixed to metal clips

M300052 100mm wide x 5mm thick m 16.50

M300053 150mm wide x 5mm thick m 24.80

M300054 Add or deduct for each 25mm in width for item (M300052) and m 4.20
(M300053)

M300055 100mm wide x 6mm thick m 17.50

M300056 150mm wide x 6mm thick m 25.38

M300057 Add or deduct for each 25mm in width for item (M300056) and m 2.81
(M300057)

Figured wired glass louvres with ground and polished edges


and with ends housed in grooved in grooves of timber frames
or fixed to metal clips

M300058 100mm wide x 5.5mm thick m 3.40

M300059 150mm wide x 5.5mm thick m 5.10

M300060 Add or deduct for each 25mm in width m 0.80

M300061 100mm wide x 6mm thick m 4.40

M300062 150mm wide x 6mm thick m 6.60

M300063 Add or deduct for each 25mm in width m 1.10

BW-M8
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M400000 STANDARD GLASS IN PANELS / DOORS

Clear tempered float glass to metal or wood frames

M400001 6mm thick m2 70.31

M400002 8mm thick m2 98.50

M400003 10mm thick m2 162.32

M400004 12mm thick m2 188.68

M400005 6mm thick m2 79.38

M400006 8mm thick m2 108.11

M400007 10mm thick m2 173.77


M400008 12mm thick m2 202.93

M500000 MIRRORS

Note:
All mirrors shall include plywood backing glued to back of
mirror.

Polished plate glass mirror with copper backing plugged to


walls including chromium plated mirrors screws and flet
washers

M500001 6mm thick m2 183.82

M500002 450 x 400 x 6mm thick with or without bevelled edges No 35.90

Bevelling to straight or circular edges including mitres and


scallops

M500003 8mm wide m 58.10

M500004 10mm wide m 61.67

M500005 12mm wide m 68.90

Convex mirrors with brackets

M500006 400mm diameter No 154.35

M500007 620mm diameter No 307.80

M500008 700mm diameter No 150.00

BW-M9
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M500000 MIRRORS (CONT'D)

Note (Cont'd):
All mirrors shall include plywood backing glued to back of
mirror.

One way mirror of approved type

M500009 6mm thick m2 90.10

Polished plate tinted glass mirror with copper backing


plugged to wall including chromium plated mirror screws and
felt washers

M500010 6mm thick m2 164.10

M600000 GLASS SHELVES

6mm thick glass shelf with edges around complete with


chromium plated brass brackets screwed to wall

M600001 600 x 125mm wide No 14.58

M700000 SOLAR CONTROL FILM

M700001 Solar control film (light transmission 75%; infra-red rejection 85%; m2 90.94
ultra-violet rejection 99%; solar energy rejected 50%)

M700002 Supply and line new or existing glass louvres and panels with m2 21.10
approved insulating film in accordance with the manufacturer's
instructions

M700003 Supply and line new or existing glass louvres and panels with m2 47.30
approved frosty silver, bronze or gold insulating film in accordance
with the manufacturer's instructions

M700004 Supply and install solar protective film on existing metal framed m2 22.00
top hung window

M700005 Supply and install 0.1mm thick approved (clear & exposed to m2 37.40
weather) shatter resistant film on existing glass panel

M700006 Supply and install 0.1mm thick approved (clear & not exposed to m2 29.80
weather) shatter resistant film on existing glass panel

M700007 Supply and install 0.1mm thick approved (tinted & not exposed to m2 33.80
weather) shatter resistant film on existing glass panel

BW-M10
M : GLAZING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

M800000 POLYCARBONATE SHEET


m2
M800001 Supply and install in new polycarbonate sheet (any type and 345.80
thickness) completed with supporting frames/ bearers, etc,

M800001 Replacement polycarbonate sheet (any type and thickness) m2


completed with supporting frames/ bearers, etc, include dismantle
existing and remove off site, make good to affected areas. 95.04

BW-M11
SECTION N: PAINTING & DECORATING
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N 100000 DEMOLITION / ALTERATIONS

N 100001 m2 2.10
Taking down existing metal or plastic signboard, removing off site
and making good works disturbed

N 100002 Taking out existing signboard posts including grubbing up concrete m 2.00
foundations as directed removing off site and filling voids with
earth well rammed (length measured from top of concrete base)

N200000 PREPARATION OF EXISTING SURFACES


Stripping out existing paintwork to substrate; including
making good damaged surfaces and preparing to receive new

N200001 Manually scraping down existing paintwork m2 1.20

N200002 Burning off existing oil paintwork m2 2.30


N200003 m2 3.65
Mechanically grinding down existing paintwork to bare plaster
including washing surfaces
N200004 m2 2.50
High pressure water jet cleaning to remove existing paintwork
including washing down surfaces

N200005 m2 0.76
Sandpapering existing paintwork on woodwork including rubbing
down, stopping, knotting and bare patches

N200007 Stripping out existing paintwork on metalwork including cleaning with m2 1.20
rust remover, washing, wire brushing and priming bare
patches

N300000 MASONRY, CEMENT AND PLASTER

N300001 Preparing and applying two coats of anti-fungus solution m2 2.20

N300002 Preparing and applying two coats of water repellant solution m2 2.20

N300003 Preparing and applying two coats of cement paint m2 1.80


N300004 m2 0.97
Preparing and applying one coat of anti-alkaline water-based wall
sealer
N300005 m2 1.19
Preparing and applying one coat of anti-alkaline oil-based wall
sealer

BW-N1
N : PAINTING & DECORATING
m2 1.19
N300006
Preparing and applying one coat of solvent-based acrylic wall
sealer

BW-N2
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N300000 MASONRY, CEMENT AND PLASTER (CONT'D)

N300007 Preparing and applying one coat of two pack epoxy-polyamide


coating m2 2.70

N300008 Preparing and applying one coat of two-component polyurethane


wall sealer m2 3.46

N300009 Preparing and applying one base coat 20% dilution of acrylic
emulsion paint m2 11.10

N30001 0 Preparing and applying one undercoat of acrylic emulsion paint


m2 1.08
N30001 1 Preparing and applying one finishing coat of acrylic emulsion paint m2 1.19
used for bother interior and exterior decoration

N300012 Preparing and applying two finishing coats of acrylic emulsion


paint m2 2.27

N30001 3 Preparing and applying one undercoat of vinyl silk emulsion paint
m2 1.30
N300014 Preparing and applying one body texture coat of vinyl silk emulsion m2 1.51
paint

N300015 Preparing and applying one finishing coat of vinyl silk emulsion
paint m2 1.30

N300016 Preparing and applying two finishing coats of vinyl silk emulsion
paint m2 2.48

N300017 Preparing and applying one undercoat of weather shield/borne


acrylic emulsion paint m2 1.30

N300018 Preparing and applying one finishing coat weather shield/borne of


acrylic emulsion paint m2 1.40

N300019 Preparing and applying two finishing coats of weather shield/bond


acrylic emulsion paint m2 2.70

N300020 Preparing and applying one undercoat of solvent -based acrylic


enamel paint m2 2.16

N300021 Preparing and applying one finishing coat of solvent-based alkyd


enamel paint m2 2.16

N300022 Preparing and applying two finishing coats of solvent-based alkyd


enamel paint m2 4.10

N300023 Preparing and applying one finishing coat of two pack epoxy -
polyamide cured primer m2 2.59

N300024 Preparing and applying one sprayed body texture coat of two -
component polyurethane coating m2 2.81

BW-N3
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N300000 MASONRY, CEMENT AND PLASTER (CONT'D)

N300025 m2 2.27
Preparing and applying one sealer coat of two - component
polyurethane coating
N300026 m2 3.67
Preparing and applying one finishing coat of two component
polyurethane coating

N300027 m2 7.24
Preparing and applying two finishing coats of two-component
polyurethane coating

N300028 Preparing and applying one sprayed coat of acrylated m2 2.92


polyso/isocyanate cured two-pack polyurethane resin enamel paint

N300029 Preparing and applying two sprayed coat of acrylated m2 5.94


polyso/isocyanate cured two-pack polyurethane resin enamel paint

N300030 Preparing and applying one sealer coat of water-based acrylic m2 2.27
resin fine spray texture coating
N300031 m2 2.59
Preparing and applying one sprayed body texture coat of water-
borne modified acrylic resin fine spray texture coating
N300032 m2 3.46
Preparing and applying one finishing coat of water-based reactive
acrylic resin fine spray textured coating

N300033 m2 5.62
Preparing and applying one coat of acrylic primer and two finishing
coats of high performance acrylic emulsion paint

N300034 Preparing and applying one sprayed coat of primer and one m2 12.74
finishing coats of stucco cementitious coating

N400000 WOODWORK

N400001 Preparing and applying one coat of wood preservative m2 2.60

N400002 Preparing and applying two coats of wood preservative m2 5.10

Knotting, priming, stopping, rubbing down, sanding and


applying one coat of aluminium wood primer on :

N400003 General surfaces m2 1.84

N400004 General surfaces of chicks, flush, panelled or louvred m2 2.10


doors/windows, fanlights, partitions including frames, mullions and
BW-N4
N : PAINTING & DECORATING
transomes, with one panel glazed (Measured flat overall between
external edges of frames or external edges of doors and
windows)(measured flat overall on both sides)

BW-N5
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N400000 WOODWORK (CONT'D)

Knotting, priming, stopping, rubbing down, sanding and


applying one coat of aluminium wood primer on (Cont'd):
N400005 m2 2.27
General surfaces of wooden trelliswork (measured flat overall on
both sides)

N400006 Surfaces not exceeding 100mm girth m 0.54

N400007 Surfaces exceeding 100mm and not exceeding 200mm girth m 0.86

N400008 Surfaces exceeding 200mm and not exceeding 300mm girth m 1.40

Preparing and applying one undercoat of synthetic enamel


paint on :

N400009 General surfaces m2 1.40

N400010 m2 1.62
General surfaces of chicks, flush, panelled or louvred
doors/windows (measured flat overall on both sides)
N40001 1 m2 1.84
General surfaces of wooden trelliswork (measured flat overall on
both sides)

N400012 Surfaces not exceeding 100mm girth m 0.43

N400013 Surfaces exceeding 100mm and not exceeding 200mm girth m 0.65

N400014 Surfaces exceeding 200mm and not exceeding 300mm girth m 1.08

Preparing and applying one finishing coat of synthetic enamel


paint on :

N400015 General surfaces m2 1.84

N400016 m2 2.05
General surfaces of chicks, flush, panelled or louvred
doors/windows (measured flat overall on both sides)
N400017 m2 2.27
General surfaces of wooden trelliswork (measured flat overall on
both sides)

N400018 Surfaces not exceeding 100mm girth m 0.54

N400019 Surfaces exceeding 100mm and not exceeding 200mm girth m 0.86

N400020 Surfaces exceeding 200mm and not exceeding 300mm girth m 1.40

Preparing and applying two finishing coats of synthetic


enamel paint on :

N400021 General surfaces m2 3.56

BW-N6
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N400000 WOODWORK (CONT'D)

Preparing and applying two finishing coats of synthetic


enamel paint on (Cont'd):

N 4 0 0 0 2 2 G e n e r a l s u r f a c e s of c h i c k s , f l u s h, p a n e l l e d o r l o u v r e d
doors/windows (measured flat overall on both sides)
m2 4.00
N400023 General surfaces of wooden trelliswork (measured flat overall on
both sides)
N400024 Surfaces not exceeding 100mm girth m2 4.43

N400025 Surfaces exceeding 100mm and not exceeding 200mm girth


m 1.08
N400026 Surfaces exceeding 200mm and not exceeding 300mm girth
m 1.62
Preparing and applying one coat of water based polyurethane
primer on : m 2.70

N400027 General surfaces

Preparing and applying one coat of varnish on :

N400028 General surfaces m2 4.10

N 40 00 29 G en eral s urf ac es of c hi c ks , f l us h, pan el l ed or l ouv re d


doors/windows, fitments, partitions including frames, mullions and
transomes (measured flat overall between external edges of
frames or external edges of door and windows) (measured flat m2 2.70
overall on both sides) m2 2.81
N400030 General surfaces of wooden trelliswork (measured flat overall on
both sides)
N400031 Surfaces not exceeding 100mm girth

N400032 Surfaces exceeding 100mm and not exceeding 200mm girth m2 2.92
N400033 Surfaces exceeding 200mm and not exceeding 300mm girth
m 0.86
Preparing and applying two coats of varnish on :
N400034 General surfaces m 1.19

N 4 0 0 0 3 5 G e n e r a l s u r f a c e s of c h i c k s , f l u s h, p a n e l l e d o r l o u v r e d m 2.05
doors/windows (measured flat overall on both sides)

N400036 General surfaces of wooden trelliswork (measured flat overall on


both sides)
m2 5.18
N400037 Surfaces not exceeding 100mm girth m2 5.29

m2 5.40

m 1.62

BW-N7
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N400000 WOODWORK (CONT'D)

Preparing and applying two coats of varnish on (Cont'd):

N400038 Surfaces exceeding 100mm and not exceeding 200mm girth m 2.38

N400039 Surfaces exceeding 200mm and not exceeding 300mm girth m 3.89

Preparing and applying one coat of polyurethane based


varnish on:

N400040 General surfaces m2 5.72


N400041 m2 5.83
General surfaces of chicks, flush, panelled or louvred
doors/windows (measured flat overall on both sides)
N400042 m2 5.94
General surfaces of wooden trelliswork (measured flat overall on
both sides)

N400043 Surfaces not exceeding 100mm girth m 1.73

N400044 Surfaces exceeding 100mm and not exceeding 200mm girth m 2.59

N400045 Surfaces exceeding 200mm and not exceeding 300mm girth m 4.32

N400046 General surfaces m2 11.34

N400047 m2 11.56
General surfaces of chicks, flush, panelled or louvred
doors/windows (measured flat overall on both sides)
N400048 m2 11.77
General surfaces of wooden trelliswork (measured flat overall on
both sides)

N400049 Surfaces not exceeding 100mm girth m 3.46

N400050 Surfaces exceeding 100mm and not exceeding 200mm girth m 5.08

N400051 Surfaces exceeding 200mm and not exceeding 300mm girth m 8.53
N400052 m2 1.73
Sand wood surfaces with sanding machine to a perfect even
surface and leave clean to receive polish or other decoration
(measured flat overall)
N400053 m2 5.40
Prepare and apply 2 coats of clear polyurethane coating on
woodwork (2 component system) (ditto)

N400054 Add to item (N400053) above for each additional coat of ditto m2 2.16
(ditto)

BW-N8
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N500000 METALWORK

Preparing and applying one coat of inhibitive primer on :

N500001 General surfaces m2 1.70


N500002 m2 1.40
General surfaces of glazed metal windows or doors (measured flat
overall both sides)

N500003 General surfaces of collapsible gates, metal gates, grille works etc m2 3.60
(measured flat overall on both sides)

N500004 Surfaces not exceeding 100mm girth m 0.30

N500005 Surfaces exceeding 100mm and not exceeding 200mm girth m 0.40

N500006 Surfaces exceeding 200mm and not exceeding 300mm girth m 0.50

N500007 Small pipes m 1.30

N500008 Large pipes m 2.40


Preparing and applying one coat of zinc chromate primer on :

N500009 General surfaces (measured flat overall) m2 1.75

N500010 m2 1.50
General surfaces of glazed metal windows or doors, and metal
surround or jambs, head and cill (Measured flat overall between
external edges of frames) (measured flat overall both sides)

N50001 1 General surfaces of wiremesh, expanded metal, BRC fabric etc m2 2.40
(Measured flat overall and rates inclusive of painting to both sides)

N500012 General surfaces of collapsible gates, metal gates, grille works etc m2 3.90
(measured flat overall and rates inclusive of painting to both sides)

N500013 Surfaces not exceeding 100mm girth m 0.25

N500014 Surfaces exceeding 100mm and not exceeding 200mm girth m 0.45

N500015 Surfaces exceeding 200mm and not exceeding 300mm girth m 0.60

N500016 Small pipes m 1.08

N500017 Large pipes m 2.05

BW-N9
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N500000 METALWORK (CONT'D)

Preparing and applying two coats of zinc chromate primer on


:

N500018 General surfaces m2 3.13


N500019
General surfaces of glazed metal windows or doors (measured flat m2 3.02
overall both sides)
N500020
General surfaces of wiremesh, expanded metal, etc (measured flat m2 5.94
overall both sides)

N500021 General surfaces of collapsible gates, metal gates, grille works etc m2 7.67
(measured flat overall on both sides)

N500022 Surfaces not exceeding 100mm girth m 0.97

N500023 Surfaces exceeding 100mm and not exceeding 200mm girth m 1.40

N500024 Surfaces exceeding 200mm and not exceeding 300mm girth m 2.38

N500025 Small pipes m 1.94

N500026 Large pipes m 3.56

Preparing and applying one coat of etch primer on :

N500027 General surfaces (measured flat overall) m2 2.05


N500028 m2 1.51
General surfaces of glazed metal windows or doors (measured flat
overall both sides)

N500029 General surfaces of wiremesh, expanded metal, BRC fabric etc m2 3.15
(Measured flat overall and rates inclusive of painting to both
sides).

N500030 General surfaces of collapsible gates, metal gates, grille works etc m2 3.85
(measured flat overall and rates inclusive of painting to both sides)

N500031 Surfaces not exceeding 100mm girth m 0.54

N500032 Surfaces exceeding 100mm and not exceeding 200mm girth m 0.75

N500033 Surfaces exceeding 200mm and not exceeding 300mm girth m 1.30

N500034 Small pipes m 0.97

N500035 Large pipes m 2.05

BW-N10
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N500000 METALWORK (CONT'D)

Preparing and applying one undercoat of synthetic enamel


paint on :

N500036 General surfaces m2 2.27


N500037 m2 2.16
General surfaces of glazed metal windows or doors (measured flat
overall both sides)
N500038 m2 4.21
General surfaces of wiremesh, expanded metal, etc (measured flat
overall both sides)

N500039 General surfaces of collapsible gates, metal gates, grille works etc m2 5.51
(measured flat overall on both sides)

N500040 Surfaces not exceeding 100mm girth m 0.65

N500041 Surfaces exceeding 100mm and not exceeding 200mm girth m 0.97

N500042 Surfaces exceeding 200mm and not exceeding 300mm girth m 1.62

N500043 Small pipes m 1.08

N500044 Large pipes m 2.16

Preparing and applying one finishing coat of synthetic enamel


paint on :

N500045 General surfaces m2 2.38


N500046 m2 2.27
General surfaces of glazed metal windows or doors (measured flat
overall both sides)
N500047 m2 4.43
General surfaces of wiremesh, expanded metal, etc (measured flat
overall both sides)

N500048 General surfaces of collapsible gates, metal gates, grille works etc m2 5.83
(measured flat overall on both sides)

N500049 Surfaces not exceeding 100mm girth m 0.76

N500050 Surfaces exceeding 100mm and not exceeding 200mm girth m 1.08

N500051 Surfaces exceeding 200mm and not exceeding 300mm girth m 1.84

N500052 Small pipes m 1.19

N500053 Large pipes m 2.27

BW-N11
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N500000 METALWORK (CONT'D)

Preparing and applying two finishing coats of synthetic


enamel paint on :

N500054 General surfaces m2 4.90


N500055 m2 4.70
General surfaces of glazed metal windows or doors (measured flat
overall both sides)
N500056 m2 8.96
General surfaces of wiremesh, expanded metal, etc (measured flat
overall both sides)

N500057 General surfaces of collapsible gates, metal gates, grille works etc m2 11.90
(measured flat overall on both sides)

N500058 Surfaces not exceeding 100mm girth m 1.51

N500059 Surfaces exceeding 100mm and not exceeding 200mm girth m 2.16

N500060 Surfaces exceeding 200mm and not exceeding 300mm girth m 4.75

N500061 Small pipes m 2.48


N500062 Large pipes m 4.97

N600000 SIGNWRITING

4mm thick acrylic plates with bevelled edges and polished


surfaces; reversed silkscreen with printed text and spray
coloured background including approved hooks fixed on for
hanging or secured with approved fastener to metal, brick or
concrete backing or glued with an approved adhesive
(backing measured separately)

N600001 100 x 30mm No 14.90

N600002 150 x 150mm No 17.39

N600003 300 x 300mm No 31.64

N600004 315 x 170mm No 18.68

N600005 440 x 150mm No 18.68

N600006 1030 x 60mm No 45.36

BW-N12
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N600000 SIGNWRITING (CONT'D)

Plastic lettering cut to size


N600007 No 1.90
25 mm high plastic moveable or Numeral, cut out from 5 mm thick
plastic sheet of approved quality and colour by a Specialist,
including approved hooks fixed on for hanging or screws for
securing to timber, brickwall, concrete, etc or glued with an
approved adhesive to plastic, etc backing and finished smooth all
edges (backing measured separately)

N600008 Add for each additional 13 mm in height No 0.80

Plastic lettering engraved on plastic sheet

N600009 25 mm high plastic letterings (any colour) in bold English Capital No 0.70
Alphabet or Numeral engraved on Plastic sheet by a specialist
including finished to approval (plastic sheet to be measured
separately)

N600010 Add for each additional 13 mm in height No 0.50

Embossing lettering on metal plate

N60001 1 Embossing English Roman letter or numeral 50 mm high No 2.60

N600012 Add or Deduct for each 13 mm in height No 1.00

N600013 Embossing one FULL STOP or COMMA or DASH etc No 0.40

Lettering in bold english capital alphabet or numeral


engraved on 16 gauge aluminium sheet and paint letter with
approved paint by a specialist including finished to approval
(aluminium sheet to measured separately)

N600014 25 mm high lettering No 1.70

N600015 Add for each additional stage of 13 mm in height No 0.30

Write or stencil roman letter or numeral, chinese, tamil or jawi


character, circle, full stop, comma, colon using enamel or
aluminium paint on any type of surface in any position

N600016 Writing not exceeding 25 mm high No 2.00

N600017 Add for each extra 13 mm in height No 0.20

Ditto using gold paint ditto

N600018 Writing not exceeding 25 mm high No 2.40

N600019 Add for each extra 13 mm in height No 0.30

BW-N13
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N600000 SIGNWRITING (CONT'D)

Write or stencil roman letters or figures, chinese, tamil or jawi


characters or circles, full stop, comma, colon using approved
colour "scotch" light ink or other approved transparent ink on
retro-reflective sheeting surface in any position

N600020 Writing not exceeding 25 mm high No 6.50

N600021 Add for each extra 13 mm in height No 2.90


30mm thick acrylic block cut-out letterings with spray painted
colour mounted on 2mm thick aluminium 'U' tray with 50mm
built-up in sprayed colours including fixing accessories

N600022 300 x 100mm No 217.40

30mm thick acrylic block cut-out letterings with spray painted


colour mounted on 3mm thick aluminium plate including
fixing accessories

N600023 100 x 150mm No 93.20


3mm thick transparent acrylic state flag with bevelled edges
and reverse silkscreen printing including fixing accessories

N600024 460 x 690mm No 55.94

Vinyl self-adhesive signages on glass surfaces

N600025 Double continuous each bands 50mm wide m 19.30

N600026 'Push' and 'Pull' signs 150mm length and 30mm wide No 11.80

N600027 Fireman access panel 'triangular symbol' 150mm high No 9.94

N600028 75 mm high die-cut vinyl letterings No 2.10

N600029 55 mm high die-cut vinyl letterings No 1.20

N600030 20 mm high ditto No 0.50

N600031 50 mm high type set and hand cut chinese characters No 1.80

N600032 200 mm high die-cut vinyl numerals No 4.50

N600033 100 mm high ditto No 2.30

BW-N14
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N600000 SIGNWRITING (CONT'D)

Retro-reflective and reflective sign


N600034 m2 89.30
Supply and paste high intensity retro-reflective sheeting (any
colour) on any surfaces, in any position

N600035 Ditto engineering grade reflective base ditto m2 37.10

N600036 Extra over above items (e) & (f) for area less than 0.50 m2 m2 11.00

N600037 50 mm lettering using high intensity base sheeting No 4.70

Retro-reflective and reflective sign (Cont'd)

N600038 Add or Deduct for each 10 mm height No 0.80

N600039 Arrow using high intensity base sheeting No 4.20


N600040 No 0.50
50 mm high lettering using engineering grade reflective base
sheeting

N600041 Add or Deduct for each 10 mm height No 0.10

N600042 Arrow using engineering grade reflective base sheeting No 0.40

3mm thick natural anodised aluminium box lettering in bold


capital alphabet or numeral fabricated from approved quality
by a specialist, including approved hooks fixed on for
hanging or secured with approved fastener to metal, brick or
concrete backing and finished smooth all edges (backing
measured separately)

N600043 200mm high lettering in four official languages No 97.20

N600044 450mm high lettering in English language No 124.20

N600045 100 mm high English/Tamil lettering No 27.90

N600046 150 mm high ditto No 33.60

N600047 150 mm high Chinese Character No 51.30

N600048 180 mm high ditto No 58.30

BW-N15
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N600000 SIGNWRITING (CONT'D)

50mm thick fluorocarbon coated aluminium box lettering in


bold capital alphabet or numeral fabricated from approved
quality by a specialist, including approved hooks fixed on for
hanging or secured with approved fastener to metal, brick or
concrete backing and finished smooth all edges (backing
measured separately)

N600049 450mm high lettering in English language No 198.72

Dark bronze/bronze aluminium box lettering in bold capital


alphabet or numeral fabricated from approved quality by a
specialist, including approved hooks fixed on for hanging or
secured with approved fastener to metal, brick or concrete
backing and finished smooth all edges

N600050 100 mm high English/Tamil lettering No 29.70

Dark bronze/bronze aluminium box lettering in bold capital


alphabet or numeral fabricated from approved quality by a
specialist, including approved hooks fixed on for hanging or
secured with approved fastener to metal, brick or concrete
backing and finished smooth all edges (Cont'd)

N600051 150 mm high ditto


No 38.30
No 49.50
N600052 200 mm high ditto

Stainless steel polished finish box lettering in bold capital


alphabet or numeral fabricated from approved quality by a
specialist, including approved hooks fixed on for hanging or
secured with approved fastener to metal, brick or concrete
backing and finished smooth all edges

N600053 100 mm high lettering No 24.30

N600054 150 mm high lettering No 30.80

N600055 200 mm high lettering No 36.50

N600056 250 mm high lettering No 40.50

N600057 300 mm high lettering No 44.60

N600058 600 mm high lettering No 97.20

N600059 750 mm high lettering No 105.30

BW-N16
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N600000 SIGNWRITING (CONT'D)

1mm thick stainless steel plates with bevelled edges and


polished surfaces; with chemical etching text in spray
coloured including approved hooks fixed on for hanging or
secured with approved fastener to metal, brick or concrete
backing or glued with an approved adhesive (backing
measured separately)

N600068 Not exceeding 0.5 m2 No 336.00

N600069 Exceed 0.5 m2 but not exceeding 1 m2 No 840.00

N600070 Exceeding 2 m2 and not exceeding 3 m2 No 1,050.00

Signboards

N600071 2mm thick aluminium signboard 1800 x 500mm with letterings No 245.92

Aluminium plate
N600072 m2 63.50
3 mm (gauge 10 BG) anodised aluminium plate bolted on to brick
or concrete walls (bolts and nuts included) with letterings
(measured separately) and sprayed with luminous painting
N600073 m2 11.60
24 gauge (0.56 mm) aluminium sheeting and labour in signboard,
etc

N600074 14 gauge (2.032 mm) ditto m2 44.20

N600075 16 gauge (1.63 mm) ditto m2 35.80

N600076 18 gauge (1.432 mm) ditto m2 28.90

N600077 24 gauge copper sheeting and labour in signboards etc m2 42.60


N600078 m2 12.80
Add to above items (i) to (n) for plate/sheet of area less than 0.50
m2
N600079 m2 279.50
2 mm thick natural anodised aluminium plate sign with engraved
coloured letterings (any height and width) in four languages all to
the approval of the SO

N600080 Ditto but with spray painted letterings (any height and width) m2 251.10
N600081 m2 344.30
Ditto but with aluminium cut-out letterings (any height and width)
including steel frame sections, brackets and plywood backing in
four languages ditto

BW-N17
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N600000 SIGNWRITING (CONT'D)

Mild steel post not exceeding 2m high from ground level, one
end cast in and including concrete (Grade 20A) foundation
and other end with all necessary supporting mild steel braces
and plates holed to receive signboard. (rate includes
excavation, formwork and removal of excavated materials off
site)

N600082 50mm diameter single post No 125.60


N600083 100mm diameter single post No 162.00

N600084 50mm diameter double posts Set 166.10


N600085 100mm diameter double posts Set 210.60
N600086 Add to above item (N600082) for each additional sta ge of 100mm No 1.60
in length
N600087 Add to above item (N600083) for each additional stage of 100mm
in length No 2.40

N600088 Add to above item (N600084) for each additional stage of 100mm
in length Set 3.20
N600089 Add to above item (N600085) for each additional stage of 100mm
in length Set 4.90

Uni-Sign complete with cappings and frames, natural


anodised aluminium face plate and black die-cut vinyl text

N600090 50mm high x 250mm wide


N600091 100mm high x 500mm wide
No 28.40
Uni-Sign complete with cappings and frames, reversed No 51.00
silkscreen printed text and sprayed painted background

N600092 75mm high x 300mm wide

N600093 75mm high x 400mm wide


No 28.40
N600094 150mm high x 150mm wide
No 35.60
N600095 3 mm thick acrylic sheet of approved quality and standard colour,
cut to sizes for name plates, door lining, etc including finishing No 22.30
smooth all edges to approval and all cutting and waste
m2 26.00

N600096 5 mm thick ditto


N600097 6 mm thick ditto

m2 42.80
m2 52.00

BW-N18
N : PAINTING & DECORATING

ITEM NO. DESCRIPTION UNIT RATE


(S$)

N600000 SIGNWRITING (CONT'D)

Uni-Sign complete with cappings and frames, reversed


silkscreen printed text and sprayed painted background
(Cont'd)

N600098 Add to above item for sheet of area less than 0.50 m2 m2 15.80
N600099 250 mm high die-cut pictogram of foot-print pair 13.00

N700000 WALLPAPER

Supply only wall covering with backing

N700001 Vinyl wall covering with paper backing m2 12.50

N700002 Vinyl wall covering with fabric backing m2 15.80

Sundries
N700003 m2 4.85
Lay only decorative fabric or vinyl covering; preparing, sizing
background; hanging with compatible adhesive including cutting
border strips, corners and mortices to profile

BW-N19
SECTION P: EXTERNAL WORKS
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 00000 EXTERNAL WORKS

Breaking up brick paving, asphaltic concrete layer or stone road


base, tarmacadam paved road, carpark and removing debris off
site

P100001 Not exceeding 450mm thick


m3 28.71
P100002 Exceeding 450mm thick m3 36.63
m 8.42
P100003 Cutting of tarmacadam surface, brick pavement etc using powered
diamond cutter to achieve a straight edge not exceeding 150mm
depth

P100004 Cutting of concrete pavement using powered diamond cutter to m 5.97


achieve a straight edge up to 150mm deep

P100005 Hacking out damaged pointing and repointing in cement mortar to m 3.36
existing precast slabs and pavements not exceeding 63mm thick
irrespective of widths of gaps between slabs and pavements

Road markings

P100006 Erasing existing thermoplastic road lines and markings including m2 7.70
clearing all shavings and making good surrounds

Road humps

P100007 Removing existing standard road hump and making good the m 54.00
existing road surfaces, all to the satisfaction of the S.O.

Potholes

Patching potholes with W3 hot asphalt premix of instant cold mix


including all necessary power saw cutting, cleaning and removing
loose materials, applying one layer of tack coat and compacting
premix with a mechanical hand compacter etc.

P100008 Not exceeding 0.09m2


No 22.50
P100009 Exceeding 0.09m2 and not exceeding 0.36m2 No 27.00

Notes for items (P100008) & (P100009)

In case there are more than one pothole next to each other, the
contractor is required to power saw cut the few potholes together
and patch them up as one pothole, if the area does not exceed
0.09m2 or 0.36m2 respectively instead of paying them as separate
potholes

BW-P1
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 00000 EXTERNAL WORKS (CONT'D)

Notes for items (P100008) & (P100009) (Cont'd)

If the pothole area to be patched is more than 0.36m2, then the


area shall be divided by 0.36 to work out the equivalent number of
potholes e.g. 1 .00m2 ÷ 0.36 = 2.7 Nos. only

Surface peeling off should not be considered as potholes, if


patching is required the contractor must break up and remove the
present layer to a depth of 75mm below the carriageway level
before considering it as a pothole for patching

Aeration precast concrete slabs

P100010 Taking out existing precast slab/aeration slabs and removing off m2 2.61
site

P100011 Taking out existing precast slab/aeration slabs, stack up for re-use m2 3.16
and removing damaged pieces off site
m2 3.77
P100012 Selecting from stack and laying aeration precast concrete slabs
including filling all voids with top soil and turf, excavating to
formation, trimming and removing surplus excavated material off
site

m2 3.70
P100013 Selecting from stack and laying only precast slab including jointing
in cement mortar (1:3), excavation and trimming to formation and
removing surplus excavation materials off site (new slabs
measured separately)

Interlocking concrete blocks

m2 2.59
P100014 Taking out existing interlocking concrete blocks and removing off
site

P100015 Taking out existing interlocking concrete blocks, stack up for re- m2 3.24
use and removing damaged pieces off site
m2 4.00
P100016 Selecting from stack and laying interlocking concrete blocks
excavating to formation, trimming and removing surplus excavated
material off site

Precast concrete kerbs

m 2.20
P10001 7 Taking out and stack on sit e f or reuse precast concrete
divider/kerbs (any size) and removing damaged pieces off site

P100018 Selecting from stack, laying and jointing divider/kerb in cement and m 4.01
sand (1:3) including excavating to formation backfill and removing
surplus excavated materials off site

BW-P2
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 00000 EXTERNAL WORKS (CONT'D)

Precast concrete kerbs


P100019 m 2.24
Taking out existing precast concrete kerbs/divider and removing
off site

Surface water drains

Surface water drains in replacement including hacking up


existing, removing debris, joining up to existing and
temporarily diverting drains as necessary and making good
(Note: For depth exceeding 300mm, the sides should be
150mm thick)

P100020 150mm wide internally and not exceeding 150mm deep to invert m 40.02

P100021 Add to above for each additional stage of 25mm depth to invert m 2.27

P100022 225mm wide internally and not exceeding 225mm deep to invert m 54.25

P100023 Add to above for each additional stage of 25mm depth to invert m 2.88

P100024 300mm wide internally and not exceeding 225mm deep invert m 57.69

P100025 Add to above for each additional stage of 25mm depth to invert m 3.30

Extra over surface water drains in replacement (any width) for


forming cascade

P100026 Not exceeding 150mm drop m 3.90

P100027 Exceeding 150mm and not exceeding 300mm drop m 6.80


P100028 m 3.97
Hacking up existing surface water drains and removing debris off
site
P100029 m 3.76
Cutting out cracks in surface water channels or drains (any type &
size) including removing silt and cutting grass on banks

Hacking up, regrading and recement inverts, sides and tops of in-
situ concrete drains (length of drain measured)

P100030 Not exceeding 300mm internal width m 13.50

P100031 Exceeding 300mm and not exceeding 450mm thick internal width m 20.41

BW-P3
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 00000 EXTERNAL WORKS (CONT'D)

Surface water drains (Cont'd)

Surface water drains in replacement including hacking up


existing, removing debris, joining up to existing and
temporarily diverting drains as necessary and making good
(Note: For depth exceeding 300mm, the sides should be
150mm thick) (Cont'd)

P100032 Precast concrete covers 50mm thick over drains, sumps, septic m2 25.06
tanks, etc complete with recesses, rebates, grooves, holes, hand-
holds, mild steel flush lifting rings, etc with and including approved
fabric reinforcement and top surface rendered smooth to falls

P100033 Add or deduct to/from item (P100029) above for each additional m2 3.78
stage of 15mm in thickness

P100034 Taking out precast concrete channel drains (any width and type) m 12.96
including side slabs if any, removing debris off site, temporarily
divert drains as necessary and making good surround (new sand
beds and channels shall be measured separately)

P100035 Taking out precast concrete channel drains (any width and type), m 19.44
including side slabs if any, trim earth to fall, relay existing channel
drains, removing debris off site; jointed in cement mortar (1.3) and
temporarily divert drains as necessary and making good (new
sand beds and channels shall be measured separately)

P100036 Break up damaged half-round precast drain channels and relay m 11.00
225mm diameter new channels in cement mortar (1:3) to falls
including makiong good sides of channels and removuing debris to
ENV's dumping ground

P100037 Break up damaged half-round precast drain channels and relay m 13.00
300mm diameter new channels in cement mortar (1:3) to falls
including makiong good sides of channels and removuing debris to
ENV's dumping ground

Chain link fencings

P100038 Removing existing fences (any type) complete with posts, struts, m2 2.86
foundations, anti-climb arm, creepers, etc. as directed and
removing off site including making good work disturbed. (length of
fence measured but height measured from top of foundation to
apex of post or anti-climb arm if applicable)

P100039 Taking out existing chain link mesh only (any type) and removing m2 0.99
off site (measured nett area of mesh)

BW-P4
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 00000 EXTERNAL WORKS (CONT'D)

Chain link fencings (Cont'd)

P100040 Taking out as necessary and tighten existing chain link mesh only
or refixing in new position including providing new straining wires, m2 3.63
bolts, and staples to match existing. (measured nett area of mesh)

P100041 Taking out existing chain link fencing complete with posts, struts,
concrete bases, etc. and set aside for re-use including removing m2 3.19
debris off site and making good works disturbed (measured nett
area of mesh)

P100042 Taking from stack and fix only existing chain link fencing in new
positions complete with posts, struts, beading, etc. including m2 3.74
providing new straining wires, bolts and staples to match existing
(measured nett area of mesh) (new foundation measured
separately)

P100043 Cutting and removing grass, shrubs, creepers and hedges on one
side of fence and clearing away of site (measured nett) m2 1.10

P100044 Taking out existing tubular or mild steel angle fence posts, struts,
etc. (any height) including foundations when directed, removing off No 3.41
site, making good work disturbed or preparing to receive new

P100045 Cutting and removing part of tubular or mild steel angle fence strut, post
or anti-climb arm not exceeding 1 m in length and replacing with No 9.79
new to match existing including removing existing concrete
foundations, taking out fence (any type), site welding, refixing,
tightening, providing new bolts, staples, etc. and 3 coats of
aluminium or enamel paint

P100046 Add to above item (P100042) for each additional stage of 100mm
in height No. 1.10

P100047 Refixing existing tubular or angle fence posts (any size and any
height) (foundation measured separately) m 1.70

Replacing mild steel angle posts/struts in isolated position


including taking out existing if any and with minimum 300mm long
posts/struts embedded in concrete foundation and all necessary
tying wires, split pins, drilling holes and 3 coats of aluminium or
enamel paint

P100048 50 x 50 x 6mm mild steel angle posts/struts

P100049 65 x 65 x 6mm mild steel angle posts/struts m 11.11

P100050 75 x 75 x 6mm mild steel angle posts/struts m 12.80

m 14.70

BW-P5
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 00000 EXTERNAL WORKS (CONT'D)

Gates m2 25.85

P100051 Taking out metal gate (any type), cut out damaged or corroded
portions, providing new in replacement, including welding, refixing,
easing and removing debris off site (replacement of ironmongery
and painting measured separately)
m2 4.32
m 9.05
P100052 Taking out existing fence gates and removing off site

P100053 Taking out existing gate posts, including grubbing up concrete


foundations as directed, removing off site and filling voids with
earth well rammed. (length measured from top of concrete base)

Basketball accessories No 67.32

P100054 Replacing existing basketball rings with new including painting and
removing off site No 71.28

P100055 Taking out existing basketball stands and removing off site
including grubbing up concrete foundations and making good
works disturbed to match existing

P200000 TARMACADAM SURFACES m3 27.00

P200001 Depositing, spreading, levelling and consolidating sub -base


material as specified with an approved type rollers to the required
thickness
m3 36.40

P200002 Base course with crusher run granite aggregate of maximum size
125mm down including rolling with suitable rollers, watering and
blinding with approved material, irrespective of thickness in layers
as specified m3 46.40

P200003 Graded granite aggregates of maximum si ze 50mm down


including compacting in layers with suitable roller to required level
and grade m2 2.40

P200004 Depositing, spreading, pulverising and grading the soil -cement


(mixing with water as directed by Superintending Officer) and
compacting, finishing and curing the subgrade/subbase m2 0.40

P200005 Applying one coat of 60/40 bitumen emulsion tack coat properly
agitated with a mechanical agitator at the rate of 0.54 litre/m2 m2 0.80

P200006 Applying tack coat of 1 .20litres/m2 onto prepared surface (for


laying of geotextile fabric) including overlapping areas of the
fabric)

BW-P6
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P200000 TARMACADAM SURFACES (CONT'D)

P200007 Brushing, sweeping and thorough cleaning of existing bitumen m2 0.10


and/or concrete surfaces to remove all loose and superfluous
materials and ensure a perfectly dry surface, prior to the
application of the tack coat or of hotmix asphalt

P200008 Brushing, sweeping and thorough cleaning of new metalled and/or m2 0.20
soiled surfaces (use detergent if necessary) to remove all loose
and superfluous materials and ensure a perfectly dry surface, prior
to the application of the tack coat or of hotmix asphalt

Asphaltic hotmix concrete of W3, laid in one layer to approved


grade and level, compacting with suitable rollers including power
saw cutting of the edges, spraying of tack coat, all necessary
sweeping and disposal of the excavated material all as directed by
the S.O.

P200009 15mm Consolidated thickness


m2 2.70
m2 3.60
P200010 25mm Consolidated thickness

Asphaltic hotmix concrete of W3, laid in one layer to approved


grade and level, compacting with suitable rollers including power
saw cutting of the edges, spraying of tack coat, all necessary
sweeping and disposal of the excavated material all as directed by
the S.O. (Cont'd)
P200011 50mm Consolidated thickness m2 7.20

Asphaltic hotmix concrete, laid in two layers to approved grade


and level, compacting with suitable rollers including power saw
cutting of the edges, spraying of tack coat, all necessary sweeping
and disposal of the excavated material all as directed by the S.O.

P200012 75mm Consolidated thickness (25mm thick W3 and 50mm thick m2 10.40
B1 asphaltic hot mix)

P200013 100mm Consolidated thickness (50mm thick W3 and 50mm thick m2 13.10
B1 asphaltic hot mix)

P200014 125mm Consolidated thickness (50mm thick W3 and 75mm thick m2 15.90
B1 asphaltic hot mix)

P200015 150mm Consolidated thickness (50mm thick W3 and 100mm thick m2 19.30
B1 asphaltic hot mix)

P200016 Cement/granite dust roadbase (1:10) mechanically mixed at m3 74.70


moisture content not exceeding 25% laid and mechanically
compacting in layers each 150mm thick

BW-P7
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P200000 TARMACADAM SURFACES (CONT'D)

Asphalt road surface including sweeping and disposal of milled


materials off site

P200017 Not exceeding 40mm thick


m2 3.89
P200018 Exceeding 40mm and not exceeding 60mm thick
m2 4.43
P200019 Exceeding 60mm and not exceeding 90mm thick
m2 4.97
P200020 Exceeding 90mm and not exceeding 120mm thick
m2 5.29
P200021 Exceeding 120mm and not exceeding 150mm thick
m2 6.59
m2 0.10
P200022 Brushing, sweeping and thorough cleaning of existing surfaces, to
remove all loose and superfluous materials and ensure a perfectly
dry surface prior to the application of the tack coat on asphalt
concrete

P200023 Brushing, sweeping and thorough cleaning of new metalled and/or m2 0.20
soiled surfaces where rolling and sweeping of excess fines are
required for new metalled roads and washing with water and
detergent on soiled surfaces as necessary

P200024 Appling tack coat of bitumen emulsion sprayed at rate of 0.54 litres m2 0.30
/m2

Asphalt concrete supplied, weighed at an approved weigh-bridge


and laid by a mechanical spreader, properly rolled and finished
including power-saw wherever directed

P200025 Type W1, W3, W3B, W5 wearing course


m3 102.00
m3 97.20
P200026 Type W6 wearing or base course as specified in A1 - IIId

Asphalt concrete supplied, weighed at an approved weigh-bridge


and laid by a mechanical spreader, properly rolled and finished
including power-saw wherever directed (Cont'd)

P200027 Type B1 base or binder course as specified or wearing course as m3 98.80


specified in AI-IVB, AI-IVC

P200028 Supply, weigh at an approved weigh-bridge, deliver and unload as m3 95.70


directed (excluding spreading and rolling) asphalt concrete for
wearing course (as specified in Mix W1, W3, W3B and W5)
wherever directed

BW-P8
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P200000 TARMACADAM SURFACES (CONT'D)


Road markings

One coat of white thermoplastic paint 1.5mm thick for the


following :

P200029 100mm wide broken lines m 1.30

P200030 100mm wide continuous lines m 1.20

P200031 150mm wide broken lines m 2.00

P200032 150mm wide continuous lines m 1.70

One coat of white thermoplastic paint 1.5mm thick for the following
:

P200033 200mm wide continuous lines m 2.20

P200034 300mm wide continuous lines m 3.10

P200035 Other road markings exceeding 300mm wide m2 10.20

P200036 Numerals/letterings (150mm high) No 5.90

P200037 Numerals/letterings (300mm high) No 8.90

P200038 Numerals/Letterings (900mm high) No 14.90

P200039 'T' Car Lots No 6.90

One coat of white thermoplastic paint 3.0mm thick for the following
:

P200040 200mm wide continuous lines m 3.00

P200041 300mm wide continuous lines m 4.40

P200042 Single traffic arrow No 28.80

P200043 Double traffic arrow No 37.10

P200044 Triple traffic arrow No 45.60

P200045 Standard letterings/numerals (2520mm high) No 29.70


P200046 m2 14.40
Pedestrian crossings and other road markings exceeding 300mm
wide

BW-P9
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P200000 TARMACADAM SURFACES


Road markings (Cont'd)

One coat of yellow thermoplastic paint 1.5mm thick for the


following :

P200047 100mm wide continuous lines m 1.30

P200048 150mm wide continuous lines m 1.70

P200049 200mm wide continuous lines m 2.30

P200050 300mm wide continuous lines m 3.70

P200051 450mm wide continuous lines m 4.90

One coat of yellow thermoplastic paint 3.0mm thick for the


following :

P200052 200mm wide continuous lines m 3.20

P200053 300mm wide continuous lines m 4.60

P200054 450mm wide continuous lines m 7.00

P200055 Standard letterings/numerals (2520mm high) No 21.00

P200056 Road marking exceeding 450mm wide m2 21.60

P200057 Standard hump hatching m 25.70

P200058 Standard bus zone No 84.20


P200059 No 316.76
2mm thick aluminium panels road sign with high reflective film
mounted on approved galvanised steel posts complete with
concrete foundation (grade 20) including excavation, disposal of
excavated material off site, formwork and painting

P200060 Standard road hump, including painting thermoplastic standard m 101.70


hump hatching

P300000 AERATION SLABS

Precast concrete slabs, of any pattern laid to any pattern and


filling all void with top soil and turf including excavation and
trimming to formation and removing surplus excavated
materials off site (sand bed measured separately)

P300001 65mm thick m2 41.14

BW-P10
P : EXTERNAL WORKS
P300002 75mm thick m2 46.19

BW-P11
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P300000 AERATION SLABS (CONT'D)

Precast concrete slabs, of any pattern laid to any pattern and


filling all void with top soil and turf including excavation and
trimming to formation and removing surplus excavated
materials off site (sand bed measured separately) (Cont'd)

P300003 100mm thick m2 51.24

P300004 115mm thick m2 57.04


P300005 120mm thick m2 61.34

P400000 INTERLOCKING PAVING BLOCKS

Precast concrete (Grade 20) interlocking paving blocks of any


pattern including filling joints with dry and sharp sand and
50mm sand bed

P400001 60mm thick m2 33.48

P400002 80mm thick m2 35.64


P400003 100mm thick m2 37.80

P500000 ROADSIDES KERBS

Precast concrete (grade 20) in roadside kerbs and dividers as


shown in the Appendix 6 to 8 herein including all necessary
reinforcement, formwork, excavation, removal of surplus
excavated materials, backfilling, laying, bedding, jointing and
pointing in cement mortar (1:3) (concrete base measured
separately)

P500001 100 x 225 mm size Type K1 m 41.26

P500002 100 x 225 mm size Type K1A m 41.26

P500003 100 x 300 mm size Type K2 m 42.12

P500004 100 x 300 mm size Type K2A m 42.12

P500005 100 x 450 mm size Type K3 m 50.22

P500006 100 x 450 mm size Type K4 m 50.22

P500007 100 x 600 mm size Type K5 m 51.90

P500008 100 x 600 mm size Type K6 m 51.90

BW-P12
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P500000 ROADSIDES KERBS (CONT'D)

Precast concrete (grade 20) in roadside kerbs and dividers as


shown in the Appendix 6 to 8 herein including all necessary
reinforcement, formwork, excavation, removal of surplus
excavated materials, backfilling, laying, bedding, jointing and
pointing in cement mortar (1:3) (concrete base measured
separately)

P500009 100 x 600 mm size Type K6A m 51.90

P500010 100 x 300 mm size Type K7 m 42.12

P500011 100 x 300 mm size Type D1 m 42.12

P500012 100 x 300 mm size Type D2 m 42.12

P500013 100 x 450 mm size Type D3 m 45.36

P500014 100 x 375 mm size Type D4 m 44.60


P500015 100 x 300 mm size Type D5 m 42.12

P600000 GEOTEXTILE FABRIC

Geotextile fabric membrane well lapped at joints (measured


nett no allowance made for laps)
P600001 m2 3.10
Approved geotextile fabric membrane to subsoil drains and
aeration works with a minimum grab tensile strength of 270N
(ASTM Modified Method D-1 682-64 Modified Grab Method)
P600002 No 3.78
Approved geotextile fabric membrane to wrapping around end of
subsoil pipes
P600003 m2 4.54
Approved heavy duty type geotextile fabric membrane for
roadworks with a minimum grab tensile strength of 530N (ASTM
Method D-682-64 Grab Method)

P700000 CONVEX MIRRORS

P700001 No 343.80
800mm diameter road safety convex mirrors fixed to 65mm
diameter x 2.40m high galvanised tubular supports with bolts and
nuts including 400 x 400 x 400mm concrete foundation, excavation
and disposal of excavated material off site

P700002 No 316.80
800mm diameter road safety convex mirrors on existing
supports/lamp posts etc. with bolts and nuts

BW-P13
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)
P800000 DRAINS

Concrete (grade 25) in new surface water drain with 100mm


thick sides and semi-circular bottom, reinforced with
approved fabric reinforcement; bottom, sides and top
rendered with 15mm thick cement and sand (1:3) including
excavation, hardcore, removing surplus excavated material
off site, formwork, laying to falls, bends, stopped ends, etc
(Note: For depth exceeding 300mm, the sides shall be
150mm thick)

P800001 150mm wide internally and not exceeding 150mm deep to invert m
90.29
P800002 Add to above for each additional stage of 25mm depth to invert m
2.27
P800003 225mm wide internally and not exceeding 225mm depth to invert m
112.86
P800004 Add to above for each additional stage of 25mm depth to invert m 2.88

300mm wide internally and not exceeding 225mm deep to invert m 118.80

P800006 Add to above for each additional stage of 25mm depth to invert m 3.30

Composite precast concrete channel drains laid to falls as


directed on and including 75mm thick sand bed, with joints
grouted in cement mortar (1:3) and rendering top with 25mm
thick cement and sand (1:3) and including all necessary
excavation, trimming, disposal of surplus excavated
materials, backfilling, etc

P800007 Type C1 m 25.16

P800008 Type C2 m 28.16

P800009 Type C3 m 31.16

P800010 Type C4 m 34.16

37.16
P800011 Type C5 m
40.16
P800012 Type C6 m
43.16
P800013 Type C7 m
46.16
P800014 Type C7A m
49.16
P800015 Type C7B m
112.43
P800016 Type C8 m
112.43
P800017 Type C8A m

BW-P14
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P800000 DRAINS (CONT'D)

Composite precast concrete channel drains laid to falls as


directed on and including 75mm thick sand bed, with joints
grouted in cement mortar (1:3) and rendering top with 25mm
thick cement and sand (1:3) and including all necessary
excavation, trimming, disposal of surplus excavated
materials, backfilling, etc (Cont'd)

P800018 Type C8B m 115.43

P800019 Type B1 m 48.71

P800020 Type B2 m 52.81

P800021 Type B3 m 125.82

Extra over precast concrete channel drains (any width) for forming
cascades

P800022 Not exceeding 150mm drop No 15.12

P800023 Exceeding 150mm but not exceeding 300mm drop No 19.98


Precast concrete pipes Class 'L' complying with SS 183 butt
jointed with cement and sand (1:1) mortar laid in trench to
correct grades and lines (trenches measured separately)

P800024 300mm diameter m 53.57

P800025 450mm diameter m 83.70

P800026 600mm diameter m 112.75

P800027 750mm diameter m 144.40

P800028 900mm diameter m 197.86

P800029 300mm diameter m 60.26

P800030 450mm diameter m 88.67

P800031 600mm diameter m 126.90

P800032 750mm diameter m 170.42

P800033 900mm diameter m 237.49

BW-P15
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P900000 CHAIN LINK FENCING

Galvanised chain link mesh fencing with straining wire at


600mm centres in new work or fixed on top of existing fence
including linking to existing, comprising a combination of
some of the following items (measured nett area of mesh)

P900001 50mm mesh x 3.25mm (10 SWG) galvanised chain link mesh with m2 7.37
strand of 4.88mm (6 SWG) straining wires

P900002 50mm mesh x 3.66mm (9 SWG) galvanised chain link mesh with m2 8.36
strand of 4.88mm (6 SWG) straining wires

P900003 50mm mesh x 4.08mm (8 SWG) galvanised chain link mesh with m2 9.60
strand of 4.88mm (6 SWG) straining wires

P900004 63mm mesh x 4.08mm (8 SWG) galvanised chain link mesh with m2 8.50
strand of 4.88mm (6 SWG) straining wires

P900005 50mm mesh x 3.25mm (10 SWG )(total thickness) galvanised m2 8.30
chain link mesh with strand of 4.88mm (6 SWG) (total thickness)
straining wires both coated with polyvinyl chloride coating. (Note :
wire thickness 13 SWG or 2.34mm)

P900006 50mm mesh x 3.66mm (9 SWG )(total thickness) galvanised chain m2 9.50
link mesh with strand of 4.88mm (6 SW G) (total thickness)
straining wires both coated with polyvinyl chloride coating. (Note:
wire thickness 12 SWG or 2.64mm)

P900007 50mm mesh x 4.08mm (8 SWG )(total thickness) galvanised chain m2 10.60
link mesh with strand of 4.88mm (6 SW G) (total thickness)
straining wires both coated with polyvinyl chloride coating. (Note :
wire thickness 11 SWG or 2.95mm)

P900008 Extra over above items (P9000001) to (P9000007) for infilling the m2 15.84
mesh with one way aluminium slates including 2 coats of enamel
paint on both sides

P900009 Extra over above items (P9000001) to (P9000007) for infilling the m2 27.72
mesh with double way aluminium slates including 2 coats of
enamel paint on both sides

BW-P16
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P900000 CHAIN LINK FENCING (CONT'D)

Posts for fence (any type) consisting of mild steel angle posts
spaced at 3.00m centres with corner, intermediate and end
posts, each post with bottom fixed on top of concrete/brick
base or wall including holding down angles and bolts or
welded to top of existing posts or bottom with minimum
300mm long embedded into and including 300 x 300 x 500mm
concrete foundation, all necessary tying wires, split pins,
drilling holes and painting with one coat of inhibitive primer
and two coats of aluminium or enamel paint. (measured nett)

P900010 50 x 50 x 6mm thick angle posts with 75 x 75 x 6mm thick corner, m2 4.95
intermediate and end posts

P900011 65 x 65 x 6mm thick angle posts with 90 x 90 x 6mm thick corner, m2 5.83
intermediate and end posts

P900012 75 x 75 x 6mm thick angle posts with 100 x 100 x 6mm thick m2 6.60
corner, intermediate and end posts

Posts for fence (any type) consisting of mild steel tubular


posts spaced at 3.00m centres and top and bottom rails, each
posts with bottom welded to 250 x 250 x 3mm thick flange
plates including embedding posts with minimum 600mm long
into and including 500 x 500 x 750mm concrete foundation as
shown in Appendix 48 including all necessary tying wires,
split pins, drilling holes and painting with one coat of
inhibitive primer and two coats of aluminium or enamel paint
and including staging (measured nett area of mesh)

P900013 89mm diameter x 5.4mm thick tubular posts with 76mm diameter x m2 20.68
5.4mm thick tubular top and bottom rails

P900014 89mm diameter x 5.4mm thick API tubular posts with 76mm m2 24.09
diameter x 5.4mm thick API tubular top and bottom rails

BW-P17
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P900000 CHAIN LINK FENCING (CONT'D)

Mild steel angle struts for fence, two to each intermediate and
corner posts, one to each end post, spaced at 12m centres
and inclined at 60 degrees to post, one end of strut bolted or
welded to post, the other end split with minimum 300mm
long, cast in and include concrete foundation as per drawing
shown in Appendix 47 and including all necessary tying
wires, split pins, drilling holes, painting with one coat of
inhibitive primer and two coats of aluminium or enamel paint
(nett area of mesh measured)

P900015 50 x 50 x 6mm thick angle struts


m2 2.90
P900016 65 x 65 x 6mm thick angle struts m2 3.20

P900017 75 x 75 x 6mm thick angle struts m2 3.41

Mild steel pipe tubular struts, two to each intermediate, one to


each end post spaced at 12m centre and inclined at 45
degrees to post, one end of strut bolted or welded to post, the
other end welded to and including 250 x 250 x 3mm thick
mild steel plate cast in and including concrete foundation as
shown in Appendix 48 and including all necessary tying
wires, split pins, drilling holes, painting with one coat of
inhibitive primer and two coats of aluminium or enamel paint
(measured nett area of mesh)

P900018 76mm diameter x 5.4mm thick API tubular struts


m2 4.51
m2 0.99
P900019 25 x 3mm thick mild steel clamp bars at every posts including bolts
and nuts, drilling and painting with one coat of inhibitive primer and
two coats of aluminium or enamel paint (measured nett area of
mesh)

P900020 76mm diameter x 5.4mm thick mild steel tubular struts m2 3.85

BRC weldmesh fencing

m 151.20
P900021 2200mm high powder coated galvanised BRC weldmesh fencing
of 5mm diameter x 150 x 150mm mesh with 70 x 45mm diameter
'I' post spaced at 2400mm centre complete with close end capping
with 250 x 250 x 500mm concrete (grade 15) footing

BW-P18
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P900000 CHAIN LINK FENCING (CONT'D)

BRC weldmesh fencing (Cont'd)

Supply, delivery and installation of 3m high 4mm diameter high


strength steel wires manufactured to SS18 with the strength of
485N/mm2 and to SS32 and welded together to form a rectangular
mesh of grid size not exceeding 25mm vertically centre to centre
and 75mm horizontally centre to centre. The fence post shall be of
75mm x 75mm x 3mm thk hot rolled structural steel hollow section.
The kerb shall be constructed using grade 30 concrete and the
dimension shall be 150mm width and 400mm depth of which
250mm must be buried in the ground and all necessary excavation
and concrete foundation to posts

P900022 For horizontal ground


m 150.00
P900023 For sloping ground (up to 45 degrees) m 170.00
m2 25.00
P900024 Replacement of weldmesh fencing for any sizes (for one to one
replacement of same type)

Supply & install weldmesh main gate consisting of 4mm diameter


high strength steel wires manufactured to SS18 with the strength
of 485N/mm2 and to SS32 and welded together to form a
rectangular mesh of grid size not exceeding 25mm vertically
centre to centre and 75mm horizontally centre to centre including
matching framing, immediate railing and cross braces, hinges,
stops, guide plates, drop bolts, padlock bolts, gate post and footing
etc

P900025 For area up to 1 0m2


m2 200.00

P900026 For area up to 20m2 m2 240.00


m2 280.00
P900027 For area up to 30 m2

P1 000000 GATES

Metal gate consisting of framing with necessary matching


intermediate rails and cross braces, and 50 x 50 x 3.25mm
weldmesh or galvanised chain link 50mm mesh x 3.25mm
(gauge 10) infilling including hinges, stops, guide plates, drop
bolts, padlock bolts, etc. and three coats of enamel paint after
installation
m2 74.25
P1000001 50mm diameter tubular hollow section or 65 x 38 x 6mm thick mild
steel angle framing
m2 66.88
P1000002 50 x 50 x 5mm angle framing

BW-P19
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 000000 GATES (CONT'D)

Metal gate consisting of framing with necessary matching


intermediate rails and cross braces, and 50 x 50 x 3.25mm
weldmesh or galvanised chain link 50mm mesh x 3.25mm
(gauge 10) infilling including hinges, stops, guide plates, drop
bolts, padlock bolts, etc. and three coats of enamel paint after
installation (Cont'd)

P1000003 Extra over above items (P1000001) & (P1000002) for forming m2 8.58
opening for and including one leaf of wicket door measuring not
exceeding 2.00 m2 complete with door frames, hinges and
padlock bolt

P1000004 Mild steel grille gate comprising of not exceeding 50 x 50mm thick m2 87.56
hollow section or 50mm tubular surround infilled with 25 x 6mm
thick flats complete with pivoted hinges, stops, drop bolts,
including all necessary welding and all other accessories, apply
one coat of inhibitive primer before delivery and three coats of
enamel paint after installation

P1000005 Galvanised mild steel gate consisting of 75mm diameter m2 187.11


g a l v a n i s e d t u b u l a r a s o u t e r f ra m e s i n f i l l e d wi t h 5 0 m m
tubularwelded vertically complete with 20mm diameter galvanised
steel pipe welded at a certain angle with one end to the outer
frame and the other to the vertical section including ironmongeries
and three coats enamel paint after installation

Mild steel gate posts with one end splayed and cast in
concrete base including three coats of enamel paint
(foundation measured separately) (length measured from top
of concrete base)

P1000006 75 x 75 x 6mm thick angle gate posts


m 13.53
P1000007 75mm tubular gate posts m 13.09

P1000008 100mm tubular gate posts m 23.43


m 32.78
P1000009 150mm tubular gate posts

P1100000 METAL POSTS

75mm tubular mild steel posts, one end minimum 600mm long
cast in and including concrete (Grade 20) foundation not
exceeding 750mm deep, the other end welded with steel plate,
holed for and including bolts and 3 coats paint. (rate include
excavation, formwork and removal of surplus excavated
material off site)
No 53.50
P1100001 Not exceeding 2m high from ground level

BW-P20
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1100000 METAL POSTS (CONT'D)

75mm tubular mild steel posts, one end minimum 600mm


long cast in and including concrete (Grade 20) foundation not
exceeding 750mm deep, the other end welded with steel plate,
holed for and including bolts and 3 coats paint. (rate include
excavation, formwork and removal of surplus excavated
material off site) (Cont'd)
P1100002 Exceeding 2.00m and not exceeding 2.50m high from ground level No 59.73

P1100003 Exceeding 2.50m and not exceeding 3.00m long from ground level No. 87.34

P1 200000 SPORT FACILITIES


Synthetic sport flooring for outdoor courts
P1200001 m2 15.98
Preparing and applying one coat of primer, two coats of body
texture and one finishing coat of acrylic coating system on
concrete floors
P1200002 m2 37.80
Preparing and applying one coat of primer, one coat of cementitious
slurry, one coat of body texture and one finishing coats of acrylic
coating system on concrete with vehicular traffic access

Set out and mark gamelines with two coats of acrylic coating
system

P1200003 Basketball gamelines Set 2,214.00

P1200004 Netball gamelines Set 621.00

P1200005 Volleyball gamelines Set 454.68

P1200005 Badminton gamelines Set 454.68


P1200006 m 4.00
Touching up of all games court lines with 2 coats of acrylic coating
system

P1200007 m2 95.04
50mm Cast in-situ vehicular rubberised safety flooring comprising
of 10mm thick coloured ethylene propylene diene-poly nethylene
(EPDM) rubber granules top layer and 40mm thick black shredded
rubber bottom layer

P1200008 Cast in-situ non-vehicular rubberised safety flooring comprising of m2 114.05


10mm thick coloured ethylene propylene diene -poly nethylene
(EPDM) rubber granules top layer and thick black shredded rubber
bottom layer

BW-P21
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

1 200000 SPORT FACILITIES (CONT'D)

Synthetic sport flooring for outdoor courts (Cont'd)

P1200009 Cut and remove damaged cast-in-situ EPDM rubber flooring area
with or without graphic not exceeding 1 sq m and reinstate the per job 300.00
flooring including removal of existing flooring

P1200010 Add to above item for every area exceeding 1 sq m to 3 sq m


m2 108.00
Synthetic field

Supply and lay new synthetic grass complete with turfed


games lines, earthwork, drainage system and all other
necessary works. Shall be heat resistance, UV stablised and
high resistance to high chemical fungus and bacteria.

P1200011 Hockey field m2 130.00


Supply and lay new synthetic grass complete with turfed
games lines, fine sand, rubber granules, earthwork, drainage
system, and all other necessary works. Shall be heat
resistance, UV stablised and high resistance to high chemical
fungus and bacteria etc.

P1200012 Soccer field


m2 55.00
Touch up or repair damaged synthetic grass complete with
necessary works etc

Soccer field

P1200013 less than 1m2


m2 250.00
P1200014 equal or exceed 1m2 but less than 10m2
m2 120.00
P1200015 equal or more than 10m2
m2 80.00

Hocky field
P1200016 less than 1m2
m2 360.00
P1200017 equal or exceed 1m2 but less than 10m2
m2 180.10
P1200018 equal or more than 10m2
m2 120.00

Rubber top up for synthetic field

P1200019 Top up of rubber granules of grain size 1mm to 2.5mm with


spreader to spread the materials evenly tonne 1,100.00

BW-P22
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 200000 SPORT FACILITIES (CONT'D) Maintenance for

synthetic field

P1200020 Maintenance to be carried out two (2) times per year and in year 2,100.00
accordance to FIFA guidelines / standards inclusive of all necessary
machineries for the maintenance work

Volley ball posts

P1200019 75mm diameter galvanised mild steel removable volleyball postsPair 1,117.80
complete with pipe sleeves and brass sleeve covers (including excavation)

Netball posts

P1200020 75mm diameter galvanised mild steel portable netball posts Pair 807.40
complete with triangular base and heavy duty wheels

Soccer posts

P1200021 Supply and install two (2) nos. of free standing soccer posts in Pair 8,800.00
accordance with FIFA dimensions and complete with net, back bottom bar and
wheels. The goals shall be all aluminium construction and white polymer
coated. Wheels can be moved down for easy movement and up when goals are in
use.

Basketball accessories
P1200022 Pair
Basketball posts fabricated of galvanised mild steel frames complete 3,960.00
with acrylic clear backstops, hook rings and nylon nets including
painting. (foundation measured separately) (rate is for per pair of
basketball posts)
P1200023 Pair
Basketball posts fabricated of galvanised mild steel frames 3,168.00
complete with marine plywood timber backstops, hook rings and
nylon nets including painting. (foundation measured separately)
(rate is for per pair of basketball posts)
P1200024 Pair
Mobile basketball posts with weights and rollers complete with 2,009.80
marine plywood timber backstops, hook rings and nylon nets
including painting. (rate is for per pair of basketball posts)

P1200025 Acrylic clear basketball backstops with hook rings and nylon nets Pair
1,534.50
P1200026 Galvanised mild steel frames for acrylic clear basketball backstops Pair 227.00
(when necessary)

BW-P23
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 200000 SPORT FACILITIES (CONT'D)

Basketball accessories (Cont'd)

Note :

For items (P1200022) to (P1200026), if the quantity required is in


odd numbers (i.e. not in pairs). Then an additional sum of $110.00
is to be added to derive at the total cost.

For example item (P1200025) :


Three (3) nos acrylic clear basketball backstops with hook rings,
nylon nets = $[1 ,534.50/2x3] + $110.00 = $2,411.75

For item (P1200026), if the quantity is in odd numbers (not in


pairs), the total cost shall be by the usual pro-rating only)

P1200027 Form coloured cement lines, 50mm wide for basketball courts, etc m 6.50
including any necessary formwork, trowelling to match existing
level, hacking existing concrete surface and removing debris off
site.

P1200028 Form coloured lines, using mosaic or glazed floor tiles 50mm wide m 7.00
for basketball courts, etc including any necessary formwork,
trowelling to match existing level, hacking existing concrete
surface and removing debris off site.

Tennis courts

P1200029 Preparing and applying two coats of filler coats, two coats of m2 16.20
texture body and one finishing coat of acrylic court coating on
asphalt flooring

P1200030 Set out and mark tennis court gamelines with two coats of acrylic No 372.60
coating system

P1200031 75mm diameter galvanised steel tennis post 1065mm long Pair 1,490.40
complete with winding gear, tennis post welded to 200 x 200 x
10mm flange plate secured with four concrete plugs

P1200032 Tennis net of polyethylene polyurethane material, 2.5mm twine No 279.50


and braided complete with centre hook and straps

P1200033 1800mm high open mesh windscreen fixed at 600mm above the m 31.20
court surface secured with butterfly clips at maximum 300mm
centres

BW-P24
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)
P1 200000 SPORT FACILITIES (CONT'D)

Tennis courts (Cont'd)

P1200034 4000mm high hot dipped galvanised pvc powder coated welded
square mesh fencing comprising of 48mm diameter hot-dipped
galvanised tubular top, middle rails and vertical posts spaced at m 204.98
3.00m centres and bedded into and including 300 x 300 x 700mm
concrete footings (grade 15) base; infilled with 50 x 50mm hot
dipped pvc coated welded square mesh secured with M6 x 4mm
long self-driving screws with hexagonal washer and rubber stopper
to frames and finished with green enamel paint on exposed
surfaces of galvanised steel posts

P1200035 Extra over fencing for 1100 x 1950mm high galvanised and green
polyester coated gate frame comprising of 40 x 40 x 2mm square
tubular frame, infill with green PVC powder coated square weld
No. 1,242.00
mesh and complete with hinges and integrated lock key system

P1200036 Tennis lighting system comprising of 7.00m high hot -dipped


galvanised posts fixed to and including concrete foundation with
base plates and M16 rag bolts; 100 watt metal halide tennis
lighting with ballast and lamps mounted on 1 .00m long bend arm No 2,880.04
and cable wiring within court area

Squash courts

P1200037 Squash court flooring system comprising 150um clear polythene


vapour proof barrier; 45 x 45mm sawn pressure impregnated
timber floor battens; 9mm thick fully formed air cell resilient pads
and finished with 20mm thick maple grade 2 tongued and grooved
flooring in 57mm width. m2 101.90

P1200038 Preparing and applying one coat of resin primer and 6mm thick
squash court wall plastering finished with plastic trowel

P1200039 Preparing and applying one coat of primer and two coats of
rubberised wall coating system
m2 97.80
P1200040 430 x 3mm thick aluminium tell-tale plate fixed with top and bottom
50 x 30mm grooved hardwood timber battens
m2 97.50
Set out and label 50mm wide red vinyl tape playlines
P1200041 On floors No 558.90

P1200042 On walls

Set 162.00
Set 162.00

BW-P25
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 200000 SPORT FACILITIES (CONT'D)

Running Track

P1200043 Supply and lay new "sandwich" synthetic rubber system running
track consisting of the bottom layer of black rubber granules
bonded with polyurethene binder and the top layer of EPDM m2 140.00
granules embedded into the pigmental polyurethane binder,
markline marking to IAAF standard with polyurethane coating to
the whole track and D-area. New aluminium kerb for inner lane.

Touch up / Spot patching / Repair on damaged running track


complete with the use of necessary equipment and complete with
all necessary works etc m2 24.00

P1200044 less than 10m2

P1200045 equal or exceed 10m2 but less than 100m2


m2 220.00
P1200046 equal or more than 100m2 but less than 1000m2 m2 180.00
P1200047 equal or more than 1000m2 m2 140.00
m2 100.00
P1 300000 OUTDOOR FITNESS STATION

P1300001 Horizontal ladder comprising of 3700 x 700 x 2400mm high 125 x


125 square water proof balau legs and horizontal beams with
rounded edges with 560mm diameter galvanised mild steel tubular Set 952.56
crossbar at 400mm range distance and 3700 x 700 x 2200mm
high 125 x 125 square water proof balau legs and horizontal
beams with rounded edges with 560mm galvanised diameter mild
steel tubular crossbars at 400mm range distance

P1300002 Brick step up blocks comprising of two 430 x 240 x 450mm high
blocks and three 430 x 240 x 350mm high at 350mm intervals
between blocks Set 302.40

P1300003 Inclined pull up in four sections (1200 x 750mm per section)


comprising of 63mm diameter galvanised mild steel tubular
support legs and 32mm galvanised mild steel tubular cross bars Set 313.20

P1300004 Pull up bar in eight sections comprising of 2480mm high 125 x


125mm square waterproof balau support legs with rounded edges
at 1375mm intervals and 32mm diameter galvanised mild steel Set 1,452.60
tubular cross bars at 1800mm high, 2000mm high, 2200mm high
and 2400mm high

P1300005 Sit up bench in four pieces comprising of 2000 x 620 x 50mm thick
waterproof balau bench, 50mm diameter galvanised mild steel
tubular 'n' shape bar and 250mm high support leg
Set 777.60

BW-P26
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 300000 OUTDOOR FITNESS STATION (CONT'D)

P1300006 2200 x 500 x 1200mm high parallel bars comprising of 125 x


125mm square waterproof balau support legs with rounded legs
and 45mm diameter galvanised mild steel tubular parallel bars Set 345.60

P1300007 2400 x 1500mm high window comprising of 75 diameter stainless


steel tubular vertical bars and 45mm diameter stainless steel
tubular horizontal bars Set 302.40

P1300008 Press-up logs in four sections comprising of 150 x 150 x 1500m


high square waterproof balau support legs at 600mm intervals,
50mm diameter stainless steel tubular crossbars, 50mm diameter Set 1,830.60
galvanised pipe tubular crossbars and 3000 x 300mm cement
bases

P1300009 3000 x 4000mm high rope climb comprising of 125 x 125mm


square waterproof balau frame and four 3000mm long x 40mm
diameter heavy quality hemp fibre strands with upper end spliced Set 810.00
and attached to a metal holder and fastened to the frame by a
shackle and lower end spliced and bound with leathers

P1300010 3600 x 750mm high swing bridge comprising of 3600 x 300 x


50mm waterproof balau board and 125mm diameter x 500mm
high waterproof balau support pillars with rubber caps Set 270.10

P1300011 Leg raise comprising of 3600 x 305 x 50mm water proof balau
board and 125mm diameter water proof balau support pillars at
800mm, 700mm, 600mm and 500mm high Set 270.00
P1400000 RAINWATER SUMPS

Rainwater sumps constructed of 200mm thick sides with 50 x


50mm rebates to receive gratings (gratings measured
separately) and 150mm thick bottom, all reinforced with and
including fabric reinforcement, the whole laid on and
including 25mm thick sand blinding and 75mm thick
hardcore, 300mm thick granolithic concrete (grade 20)
benching, finishing internally with 20mm thick cement and
sand (1:2) rendering trowelled smooth, all necessary
excavation and disposal of excavated material off site

P1400001 600 x 600 x 700mm deep (internal) to invert No 335.02

P1400002 Add or deduct for every 25mm in depth No 5.20

BW-P27
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1400000 RAINWATER SUMPS (CONT'D)

Rainwater sumps constructed of 200mm thick sides with 50 x


50mm rebates to receive gratings (gratings measured
separately) and 150mm thick bottom, all reinforced with and
including fabric reinforcement, the w hole laid on and incl
uding 25 mm thick sand bl indi ng a nd 75 mm thick
hardcore, 300mm thick granolithic concrete (grade 20)
benching, finishing internally with 20mm thick cement and
sand (1:2) rendering trow elled smooth, all necessar y
excavation and disposal of excavated material off site
(Cont'd)

P1400003 900 x 600 x 700mm deep (internal) to invert


No 502.60
P1400004 Add or deduct for every 25mm in depth No 6.10

P1400005 1200 x 600 x 700mm deep (internal) to invert No 678.40


P1400006 Add or deduct for every 25mm in depth No 8.20

Brick sumps 450 x 450 x 450mm deep (internal) to invert


consisting of concrete (grade 20) base 100mm thick, 102.5mm
thick brick wall, finished internally (smooth) and externally
(rough) with 20mm thick cement and sand (1:2) rendering
including all necessary excavation, disposal of excavated
material off site

P1400007 450 x 450 x 450mm deep (internal) to invert


No 194.40
P1400008 Add or deduct for every 25mm in depth No 3.20

P1500000 SUB-SOIL / AGRICULTURAL DRAIN PIPES

Filling materials to surround subsoil pipes (no deduction for


pipe length)

P1500001 19mm granite aggregate fillings


m3 33.90
P1500002 Approved hardcore fillings m3 23.90

P1500003 75mm diameter m 7.75


P1500004 100mm diameter
m 10.10
P1500005 150mm diameter
m 16.70

BW-P28
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1500000 SUB-SOIL / AGRICULTURAL DRAIN PIPES (CONT'D)

Heavy duty unplasticised polyvinyl chloride Class AW subsoil


pipe 3/4 perforated laid in trench to correct grades and lines
(trench measured separately)

Extra over pipes for fittings P1500006 75mm diameter bends

P1500007 100mm diameter bends P1500008 150mm diameter bends


No 5.30
P1500009 75mm diameter tees/junctions P1500010 100mm diameter No 9.50

tees/junctions P1500011 150mm diameter tees/junctions No 32.20

No 7.30
P1 600000 THERMAL SCANNING
No 15.10
P1600001 To engage Consultant or Building Surveyor to conduct condition No 47.20
survey on external wall finishes on building façade as specified
(5th storey & below).

P1600002 To engage Consultant or Building Surveyor to conduct condition


survey on external wall finishes on building façade as specified Per Blk 1,200.00
(6th storey & above).

P1600003 To engage Consultant or Building Surveyor to conduct condition


survey on external wall finishes on building façade by visual and
Per Blk 1,350.00
thermography scanning as specified (5th storey & below and < 10
blocks).

P1600004 To engage Consultant or Building Surveyor to conduct condition Per Blk 3,200.00
survey on external wall finishes on building façade by visual and
thermography scanning as specified (6th storey & above and < 10
blocks).

P1600005 To engage Consultant or Building Surveyor to conduct condition Per Blk 3,600.00
survey on external wall finishes on building façade by visual and
thermography scanning as specified (5th storey & below and > 10
blocks).

P1600006 To engage Consultant or Building Surveyor to conduct condition Per Blk 2,800.00
survey on external wall finishes on building façade by visual and
thermography scanning as specified (6th storey & above and > 10
blocks).

Per Blk 3,150.00

BW-P29
P : EXTERNAL WORKS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

P1 600000 THERMAL SCANNING (CONT'D)

To engage Consultant or Building Surveyor to conduct condition Per


survey on external wall finishes on low rise building façade (5th Elevation
storey & below) by visual and dimension shall be Girth x Height of
the inspected thermography scanning as specified. The area:

P1600007 Up to 30m Girth x Height of the building 300.00

P1600008 Up to 60m Girth x Height of the building 600.00

P1600009 More than 60m Girth x Height of the building 1,000.00

To engage Consultant or Building Surveyor to conduct condition Per


survey on external wall finishes on low rise building façade (6th Elevation
storey & above) by visual and dimension shall be Girth x Height of
the inspected thermography scanning as specified. The area:

P1600010 Up to 30m Girth x Height of the building 350.00

P1600011 Up to 60m Girth x Height of the building 700.00


P1600012 More than 60m Girth x Height of the building 1,250.00

P1 700000 ROOT BARRIER

P1700001 Preparing, supply and lay root barrier to prevent roots from m 127.20
growing and divert the route of roots growing

P1 800000 BIRD SPIKES

P1800001 Supply and install bird spikes m 36.00

BW-P30
SECTION Q: MISCELLANEOUS
Q : MISCELLANEOUS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

Q1 00000 URGENT WORK (All rates from items Q100001 to


Q100002 below shall not be subject to percentage
adjustment)

Extra over every Works Order issued per site for


urgent repair. The following rates are based on four
men on site.

Time of call Type of commencement of work

by SO urgent repair Commence Commence


Work Within Work After One
One Hour Of Hour But Within
Call Four Hours Of
Call
S$/hour S$/hour
Q100001 From 6pm to 8am, Monday W ater-mains and other 243.00 202.50
to Friday; From 1pm to urgent works which require
8am Saturday; From 8am mobilisation of plant such
to 8am, Sunday and Public as gondola, scaffolding,
Holidays (including etc
overtime)

Q100002 From 8am to 6pm; Monday W ater-mains and other 229.50 189.00
to Friday; From 8am to urgent works which require
1pm Saturday (excluding mobilisation of plant such
overtime) as gondola, scaffolding,
etc

Q1 00003 Ded uct or add from/to item (Q1 00001) if the workmen hour 33.30
e mp l o ye d o n s i t e i s l e s s o r mo re t h a n 4 me n a s
specified (Rate is for per man)

Q100004 De d u ct or add from/to item (Q100002) if the workmen hour 12.40


e mp l o ye d o n s i t e i s l e s s o r mo re t h a n 4 me n a s
specified (Rate is for per man)

BW-Q1
Q : MISCELLANEOUS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

Q200000 LABOUR

Labourers for miscellaneous work and working on an hourly


basis and including transport to site for working and all
establishment charges, etc.

Q200001 Normal working hours (minimum 1 hour work)


Hour 3.70
Q200002 Overtime working during weekdays (minimum 1 hour work) Hour 5.00
Hour 3.80
Q200003 Overtime working during Sundays and Public Holidays (minimum 1
hour work)

Q200004 Full day of 8 normal working hours Day 27.00

Semi-skilled tradesmen (e.g. concretor, steel-bender, mason,


drainlayer, carpenter, steel-worker, electrician, plumber,
glazier, painter, driver, plant driver (plants under 100 H.P.) etc.
and working on an hourly basis and including transport to
site for working and all establishment charges, etc.

Q200005 Normal working hours (minimum 1 hour work)


Hour 4.50
Q200006 Overtime working during weekdays (minimum 1 hour work) Hour 6.90

Q200007 Overtime working during Sundays and Public Holidays (minimum 1 Hour 9.10
hour work)

Q200008 Full day of 8 normal working hours Day 36.40

Artisans or skilled tradesmen (e.g. joiner, plasterer, tiler,


pavior, welder, piler, fitter, mechanic, plant operator (plants
above 100 H.P.) etc. and working on an hourly basis and
including transport to site for working and all establishment
charges, etc.

Q200009 Normal working hours (minimum 1 hour work)


Hour 4.90
Q200010 Overtime working during weekdays (minimum 1 hour work) Hour 7.30
Hour 9.70
Q200011 Overtime working during Sundays and Public Holidays (minimum 1
hour work)

Q200012 Full day of 8 normal working hours Day 39.10

BW-Q2
Q : MISCELLANEOUS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

Q3 0 0 0 00 P LANT

(Note: Unless otherwise specified, rates for hiring of plant


shall be held to include for transporting machine to and from
site, operator, fuel and petrol/diesel, maneuvering machine
about site, insurance, idling time, road tax and all
establishment charges)

Q300001 Day 259.50


Hiring of bull-dozer, backactor, face shovels or dragline not
exceeding 0.40m3 capacity or other approved heavy duty
mechanical equipment of 1.34 to 1.73 m3 bucket capacity
(including driver and attendant) for bulk excavation over site to
reduce level and subsequently filling in depressions with approved
excavated materials to make up platform or required level,
(minimum 1 day work)

Q300002 Hour 40.00


Hiring of truck crane of 20 tonnes lifting capacity (Telescopic) and
reaching approximately 30m including fuel, operator, transporting,
etc. (minimum 4 hours work)
Q300003 Hour 92.90
Hiring of up to 20m boom lift including fuel, operator, transporting,
etc. (minimum 4 hours work)

Hiring of lorry mounted with crane including fuel, operator,


transporting, etc. (minimum 4 hours work)

Q300004 61/2 tonnes lifting capacity Hour 22.30

Q300005 10 tonnes lifting capacity Hour 26.80

Hiring of air compressor including operative tools, hose and


fuel or power (no labour) (minimum 1 hour work)

Q300006 Capacity not less than 4 m3/minute Hour 7.70

Hiring of power driven pump including suction, hose, up to


20m of delivery hose, all fittings, attendant, power and
connections if required (minimum 1 hour work)

Q300007 38 to 50mm diameter Hour 8.10

Q300008 75mm diameter Hour 10.30


Q300009 Day 31.50
Hiring of vibrator 25 or 38mm diameter including operator and
hose (minimum 1 hour work)

Hiring of road roller including fuel and driver (minimum 2


hours work)

Q300010 6 tonnes capacity Hour 14.50

Q30001 1 8 to 10 tonnes capacity Hour 19.70

BW-Q3
Q : MISCELLANEOUS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

Q300000 PLANT (CONT'D)

Hiring of road roller including fuel and driver (minimum 2


hours work) (Cont'd)

Q30001 2 Hiring of power loader on rubber tyre 1.20 m3 capacity (flywheel Hour 20.40
horsepower 60 kW range) including fuel and driver (minimum 1
hour work)

Hiring of welding and cutting set (exclude labour) (Day rate


per set) (minimum 1 hour)

Q300013 Oxy-acetylene complete with torch, oxygen and acetylene


Q300014 Electric arc Hour 7.20
Hour 28.90
Q30001 5 Hiring of mechanical lawn mower with blade not exceeding 500mm
and engine power not exceeding 150 cc (exclude labour) Hour 2.30

Hiring of motor lorry including driver, grease and fuel


(minimum 2 hours work)

Q30001 6 1.50 tonnes size


Hour 4.90
Q300017 3 tonnes size Hour 7.30

Hiring of tipper lorry including driver grease and fuel


(minimum 2 hours work)

Q30001 8 5 tonnes tipper lorry (ordinary flat top)


Hour 12.80
Q300019 7 or 71/2 tonnes (ordinary heavy haulage)
Hour 17.00
Q300020 10 tonnes
Hour 23.40

Q400000 BINTANGOR SCAFFOLDING

Providing, erecting and maintaining putlog bintangor


scaffolding including all cutting, waste, scaffold boards, etc.
removing scaffolding after use and clearing debris off site

Q400001 First 100m2 m2 3.50


m2 3.00
Q400002 Second and subsequent 1 00m2

Independent bintangor scaffolding for the all as before


described (Rate inclusive of 2 layers of scaffolding) (Centre
line measured)

Q400003 First 100m2 m2 6.10

BW-Q4
Q : MISCELLANEOUS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

Q400000 BINTANGOR SCAFFOLDING (CONT'D)

Independent bintangor scaffolding for the all as before


described (Rate inclusive of 2 layers of scaffolding) (Centre
line measured) (Cont'd)

Q400004 Second and subsequent 100m2 m2 5.10

Q500000 STEEL SCAFFOLDING

Providing, erecting and maintaining putlog or framed tubular


steel scaffolding for the first 100m2 including base plates,
scaffold boards, etc. removing scaffolding after use and
clearing debris off site (Centre line measured)

Q500001 First 100m2 m2 9.60


Q500002 Second and subsequent 1 00m2 m2 8.20

Q600000 STEEL STAGING

Providing, erecting and maintaining tubular steel staging,


including platform boards, swivel castors, or base plate, etc.
transporting to and from site, maneuvering about site,
removing staging after use and clearing debris off site

Q600001 Exceeding 3.50m and not exceeding 5.00m high No 128.00


Q600002 No 25.80
Add exceeding 3.50m and not exceeding 5.00m high for labour in
dismantling, shifting to another area/room and re-erection

Q600003 Exceeding 5.00m high and not exceeding 6.50m high No 177.90
Q600004 No 32.40
Add exceeding 5.00m and not exceeding 6.50m high for labour in
dismantling, shifting to another area/room and re-erection

Q600005 Exceeding 6.50m high and not exceeding 8.00m high No 223.20
Q600006 No 39.00
Add exceeding 6.50m and not exceeding 8.00m high for labour in
dismantling, shifting to another area/room and re-erection

Q600007 Exceeding 8.00m high and not exceeding 9.50m high No 255.90
Q600008 No 45.30
Add exceeding 8.00m and not exceeding 9.50m high for labour in
dismantling, shifting to another area/room and re-erection

Q600009 Exceeding 9.50m high and not exceeding 11 .00m high No 294.40

BW-Q5
Q : MISCELLANEOUS

Q600010 No 52.10
Add exceeding 9.50m and not exceeding 11 .00m high for labour in
dismantling, shifting to another area/room, and re-erection

BW-Q6
Q : MISCELLANEOUS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

Q700000 CRADLES/GONDOLAS

Hiring of power climber, suspended cradles/gondolas of 2.00


metre length working platform including installation,
maintaining, shifting anchorages, testing, certifying by
approved Engineer, safety feature, counter weight, wire rope,
overspeed safety device, related accessories, dismantling and
removing after use, all as specified (Rate per set) (minimum 1
month)

Q700001 First month


No 1,600.00
Q700002 Each subsequent day No 56.00
No 13.20
Q700003 Extra over the above rates per month for each additional 1 .00m
length of gondola

Q700004 Extra over the above rates per month for shifting of gondola within No 69.00
the same block

Q700005 Extra over the above rates per month for shifting of gondola to a No 124.30
different block

Q800000 CLEARING OF RUBBISH

Providing transport, labour, equipment and including


dumping fees for the clearing away of rubbish from site to
contractors own dumping ground or to NEA dumping ground
at:

a) all non-incinerable debris, rubbish, garbage, waste, etc and


unwanted earth at Lorong Halus Dumping Ground, 14km
Tampines Road

b) all incinerable debris, rubbish, garbage, waste, etc at Senoko,


Tuas and Ulu Pandan Incineration Plant

c) and leave the site clean and tidy to the satisfaction of the SO.
(The following items are not applicable to work related to
normal construction work)

Q800001 Rate per lorry load of 1.5 tonne size (minimum 1 lorry load) No 120.00

Q800002 Rate per lorry load of 3 tonnes size (minimum 1 lorry load) No 130.00

Q800003 Rate per lorry load of 5 tonnes size (minimum 1 lorry load) No 140.00

Q800004 Rate per lorry load of 7 tonnes size (minimum 1 lorry load) No 150.00

BW-Q7
SECTION R: ADDITIONAL ITEMS
R : ADDITIONAL ITEMS
*To refer back to the main Clause, sub-Clause as well as the preambles for each of the following items:
ITEM NO. DESCRIPTION UNIT RATE
(S$)
SUB-SECTION : E
E610000 UNDERGROUND PIPE LEAK

E610001 Check and to trace underground pipe leak using sound detection Job 1,800.00
equipment machine MIKRON PRIMAYER test leak equipment
not exceeding 20m2

E610002 Every subsequent m2 m2 30.00

E610003 Underground CCTV survey scanning c/w report (minimum 20m Job 1,500.00
distance)

SUB-SECTION : F
F400000 FLOORING

F400020 Supply and lay timber strip floor tiles complying with bedding in No 55.00
cement and mortar grouting and pointing with white or tinted
cement on screed backing. Size : 150mm x 600mm x 8mmth.
(Not exceeding 10 pcs)

F400021 Supply and lay timber strip floor tiles complying with bedding in No 35.00
cement and mortar grouting and pointing with white or tinted
cement on screed backing. Size : 150mm x 600mm x 8mmth.
(Exceeding 10 pcs)

F1000000 FITMENTS
Fitments fixed to walls and grouted onto concrete base or
timber supports including all necessary ironmongery
(Cont’d)

F1000096 Fabricate and install Low timber cabinet not exceeding 1000mm m 400.00
height and width not exceeding 600 mm c/w swing door, fitting
and laminate finishes

F1000097 Fabricate and install High cabinet timber not exceeding 2500mm m 850.00
height and width not exceeding 600 mm c/w swing door, fitting
and laminate finishes

F1000098 Extra over for more than 2500mm ht but not exceeding 3200mm m 800.00
ht

F1000099 Extra over for per drawers ( per pc ) No 90.00

F1000100 Extra over for timber sliding door m 270.00

F1000101 Extra over for glass sliding door m 400.00

F1000102 Supply and install mild steel Boltless Rack with epoxy powder m2 750.00
coated finishing Height not exceeding 2160mm -(Maximum 600
kg of loading weight)

F11000103 Supply and install wall mounted green colour felt pin board c/w m2 90.00
single leaf swing door of aluminium casement (frame) w/ acrylic
panel and lock set

F11000104 Supply and install wall mounted white non-magnetic whiteboard m2 100.00
only

F11000105 Supply and install wall mounted casement white non-magnetic m2 400.00
whiteboard c/w 2" x 1" aluminium casement (frame) and green
colour felt pin board backing
BW-R1
R : ADDITIONAL ITEMS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

F1000106 Supply and install wall mounted casement white non-magnetic m2 700.00
whiteboard c/w 2" x 1" aluminium casement (frame), 2 pcs of
clear glass sliding door, lock set and green colour felt pin board

F1000107 Supply and install wall mounted casement white non-magnetic m2 650.00
whiteboard c/w 2" x 1" aluminium casement (frame), 2 pcs of
acrylic sliding door, lock set and green colour felt pin board

F1000108 Supply and install wall mounted casement white non-magnetic m2 800.00
whiteboard c/w 2" x 1" aluminium casement (frame), 2 pcs of
tempered glass sliding door, lock set and green colour felt pin
board

F1000109 Supply and install wall mounted casement white magnetic m2 400.00
whiteboard c/w 2" x 1" bronze aluminium casement (frame), 2
pcs of clear glass sliding door and lock set

F1000110 Supply and install wall mounted casement sliding white magnetic m2 580.00
whiteboard c/w 2" x 1" aluminium casement (frame) and green
colour felt pin board backing

F1000111 Supply and install wall mounted magnetic tempered glass writing set 1,500.00
board with white backing, polished edges c/w stainless steel
spacers and magnet buttons. (1200mm x 1500mm)

F1000112 Supply and install wall mounted magnetic tempered glass writing set 1,750.00
board with white backing, polished edges c/w stainless steel
spacers and magnet buttons. (1200mm x 1800mm)

F1000113 Supply and install 5mm thk clear acrylic for notice board c/w m2 200.00
glass panel

SUB-SECTION : K
K300000 FLOOR TILING
Cement and sand (1:3) screed backing on concrete floors
laid flat or falls to receive floor tiling, stone finishes, etc

K300030 Supply and lay 300mm x 600mm x 8mmthk matt Homogeneous m2 70.00
stoneware porcelain floor tile complying with bedding in cement
and mortar grouting and pointing with white or tinted cement on
screed backing.

K300031 Supply and lay 300mm x 600mm x 8mmthk matt Homogeneous m 12.50
stoneware porcelain floor tile to skirting , plinths, risers, kerbs and
returns etc including angles round edge etc , not exceeding
300mm high

K300032 Supply and lay 300mm x 600mm x 8mmthk polished m2 100.00


Homogeneous stoneware porcelain floor tile complying with
bedding in cement and mortar grouting and pointing with white or
tinted cement on screed backing.

K300033 Supply and lay 300mm x 600mm x 8mm thk polished m 17.00
Homogeneous stoneware porcelain floor tile to skirting , plinths,
risers, kerbs and returns etc including angles round edge etc ,
not exceeding 300mm high

BW-R2
R : ADDITIONAL ITEMS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

SUB-SECTION : G
G200000 IRONMONGERY

G200147 Supply and install Door catch with metal chain to be fixed to No 25.00
existing door frame

G200148 Supply and install 'Dorma" PT 84 Double action floor spring with No 450.00
hardware accessories and cover (per leaf per door )

G200149 Supply and install Stainless steel heavy two way dual door No 79.00
hinges to be fixed to door frame

G200150 Supply and install round knok lockset and latches with strike set 85.00
plates

G200151 Supply and install Stainless steel box flush bolts with matching No 60.00
screws. Size : 600mm diameter.

G200152 To supply and install 100mm x 300mm x 1.5mm stainless steel No 125.00
Push & Pull Plate with handle

G200153 Supply and install toilet indicator with lockset to Handicapped No 80.00
toilet. ( Optional - Handle )

G200154 Supply and install stainless steel channels section cut to required m 10.00
length, fixed to brickwork, concrete etc. Size : 25mm x 25mm x
3mm thk

G200155 Supply and install 3mm thk Stainless steel plates cut to required m2 120.00
sizes and fixed to concrete etc. including bending welding and
drilling holes etc.

SUB-SECTION : I
I300000 DOORS

I300028 Supply and install new PVC Bi - fold doors with all necessary m2 250.00
fitting including door frames

I300029 Supply and install new heavy duty PVC door hinges to existing No 30.00
toilet compartment (100mm )

I300030 Supply and install new PVC Black heavy duty leg support to toilet No 40.00
compartment

BW-R3
R : ADDITIONAL ITEMS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

SUB-SECTION : L
L100000 PLUMBING
Water closet seats and covers

L100408 Supply labour and material to replace soft-closing child & adult No 250.00
seat cover

L100409 Supply labour and material to replace soft-closing seat cover No 180.00
adult seat cover

L100410 To supply and install new adult wc closing seat cover No 200.00

L35 00000 MISCELLANEOUS

L35 00019 To supply and install Abloy Lock Model PL 321B for water tank No 110.00
cover

L35 00020 To supply and install Abloy Lock Model PL 330 for door access No 160.00

L35 00024 Supply and install Wall Hung Low-Lip Urinal c/w Built-in Sensor No 1,200.00

L35 00025 Supply and install rubber hose (minimum run 5 m ) m 3.00

L35 00026 To replace deck self-closing tap ( Model W3-R-SCT-2014) No 190.00

L35 00027 To supply and replace existing water dispenser nozzle No 150.00

L35 00028 To supply and replace water filter cartridge for water dispenser No 100.00

L35 00029 To remove existing and install new bubbler head No 200.00

L35 00030 To supply and replace sensor tap model no DLE 105AV 810 No 900.00
controller and sensor

L35 00031 To supply and replace sensor tap model no DLE 105AV 810 No 1,200.00

L35 00032 To supply and replace AWS sensor tap model Virgo No 500.00

L35 00033 To supply and replace AWS Metrix L lever basin tap No 130.00

L35 00034 To supply and replace acrylic level water indicator tube c/w Set 270.00
necessary fitting

L35 00035 To provide labour and necessary equipment to drill into water Job 130.00
tank to install new sampling tap c/w lock (water tank body and
waste out pipe)

L35 00036 Supply and install Horizontal wall mounted baby changing station Set 600.00
including all necessary mounting bracket support complete with
nylon safety strap and bag hooks

L35 00037 Supply and install Vertical wall mounted baby changing station Set 730.00
including all necessary mounting bracket support complete with
nylon safety strap and bag hooks

BW-R4
R : ADDITIONAL ITEMS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

SUB-SECTION : N
N600000 SIGNWRITING

N600100 Supply and install 2mm thk aluminiun plate c/w vinyl cut out letter m2 780.00
or powder coated base and vinyl cut out letter

N600101 Supply and install 2 mm thk aluminiun plate c/w spray paint base m2 2,800.00
and and vinyl cut out letter

N600102 Supply and install 3 mm thk acrylic plate c/w reverse printing text m2 1,000.00

N600103 Supply and install 5 mm thk acrylic plate c/w reverse vinyl sticker m2 750.00
text

N600104 Supply and install 1 mm thk SS304 stainless steel plate c/w m2 3,400.00
chemical etching and infill paint for text

N600105 Supply and install 1 mm thk SS304 stainless steel plate c/w vinyl m2 400.00
sticker text

SUB-SECTION : P
P100000 EXTERNAL WORKS

Basketball Accessories
P100056 Supply and replace existing Basketball netting and disposing off Job 100.00
site

P100057 Supply and replace existing Basketball spring system, ring and Set 480.00
netting and disposing off site.

P100058 Supply, replace and make good of existing Basketball Metal Set 520.00
frames, ring and netting (w/o backstop)

P100059 Supply and install Flag pulley and nylon string Set 200.00

Hoarding
P100060 Erection of metal hoarding not exceeding 2.5m high complete m2 100.00
with concrete footing

Rubber Humps
P100061 Supply and install new black and yellow rubber road humps No 160.00
(Size :400mm x 500mm)

P100062 Supply and install new black and yellow rubber road humps end No 100.00
cap (Size :400mm x 500mm)

BW-R5
R : ADDITIONAL ITEMS

ITEM NO. DESCRIPTION UNIT RATE


(S$)

SUB-SECTION: Q
Q100000 URGENT WORK
*Labour and transport allowance for responding to SO’s verbal
instruction to attend and diagnose critical or urgent repair work
including reporting to SO the extent and nature of the repairs
(cost of repairs to be measured separately. Time shall be taken
as the time the verbal instruction was given to the time the
Contractor reports on the nature and extend of the repairs from
site) Q100005 and Q100006

Q100005 Within one hour of SO’s verbal instruction during office hour Job 40.00

Q100006 Within one hour of SO’s verbal instruction after office hour Job 60.00

Q100007 Additional allowance incur where total work value per location Job 30.00
per job not exceed $100.00 (before % adjustment)
[not applicable if Q100005 or Q100006 is used]

Q200000 LABOUR

Q200013 License plumber submission work of underground pipe to PUB Job 600.00
Authorities

Q200014 Provide Specialist to check and service existing roller shutter Job 350.00
without replacement of any part or in whole

Q300000 PLANT
Q300021 Hiring of 1.5m scissor lift including driver, grease and fuel Hour 60.00
(minimum 2 hours works)

Q300022 Hiring of high pressure lorry jetting machine to clear manhole not Job 350.00
exceeding 1.25m depth

Q300023 Every subsequent manhole not exceeding 1.25m depth No 120.00

Q900000 STICKER
Q900001 Supply and install new reflective black and yellow sticker to M 10.00
existing Bollards ( Min : 5m length )

Q900002 Supply and install new yellow anti - slip floor sticker ( Min : 5m M 15.00
length )

Q1000000 DISPLAY
Q1000001 Supply and install Acrylic clear display holder A4 Size No 90.00

BW-R6

You might also like