You are on page 1of 9

Reinf Superstr.

03/15/2018
Project No: XXXXXXXX
Str. No.: X­XX­XXX
By: XXXXXXXXX
4  5  6  7  8  9  10  11 
BAR LIST - SUPERSTRUCTURE 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

No.  Epoxy   Black   Epoxy   Black 


Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Top of slab (Tran) E 5  94  21'­3" Str.    1,997.50          ­        2,083        ­   
Top of slab (Tran) E 5  2  3'­3" Str.        6.50          ­            7        ­   
Top of slab (Tran) E 5  2  2'­6" Str.        5.00          ­            5        ­   
Top of slab (Tran) E 5  2  3'­11" Str.        7.83          ­            8        ­   
Top of slab (Tran) E 5  311  40'­0" Str.   12,440.00          ­       12,975        ­   
Top of slab (Tran) E 5  305  4'­2" Str.    1,270.83          ­        1,325        ­   
Along Abut. (Tran) E 5  6  13'­11" Str.       83.50          ­           87        ­   
Along Abut. (Tran) E 5  6  40'­0" Str.      240.00          ­          250        ­   
Top of slab (Long) E 10  86  60'­0" Str.    5,160.00          ­       22,203        ­   
Top of slab (Long) E 10  84  30'­0" Str.    2,520.00          ­       10,844        ­   
Top of slab (Long) E 4  86  14'­10" Str.    1,275.67          ­          852        ­   
Top of slab (Long) E 4  430  40'­0" Str.   17,200.00          ­       11,490        ­   
Disclaimer
Notice of Disclaimer: The Colorado Department of
Transportation (CDOT) makes these documents
available on an "as is" basis. All warranties and
representations of any kind with regard to said BAR SUMMARY - SUPERSTRUCTURE
documents are disclaimed, including the implied EPOXY COATED NON-EPOXY COATED
warranties of merchantability and fitness for a
particular use. Under no circumstances will the CDOT,
or any of its officers or employees be liable for any Number Lbs. / Number Lbs. /
consequential, incidental, special or exemplary of Lin. Bar Lin. of Lin. Bar Lin.
damages even if apprised of the likelihood of such Ft. Size Ft. Weight Ft. Size Ft. Weight
damages occurring. The CDOT does not warrant the
documents against deficiencies of any kind. The use 516    18,475.67  #4 0.668     12,342          ­    #4 0.668        ­   
of any of these documents for work which is under 728    16,051.17  #5 1.043     16,741          ­    #5 1.043        ­   
contract with the CDOT, does not relieve the 0          ­    #6 1.502        ­            ­    #6 1.502        ­   
contractor from any obligations assumed by the 0          ­    #7 2.044        ­            ­    #7 2.044        ­   
contract, or from complete and proper fulfillment of 0          ­    #8 2.670        ­            ­    #8 2.670        ­   
the terms of the contract, nor does it entitle the
contractor to compensation for damages or loss 0          ­    #9 3.400        ­            ­    #9 3.400        ­   
which could be attributed to such use. 170     7,680.00  #10 4.303     33,047          ­    #10 4.303        ­   
0          ­    #11 5.313        ­            ­    #11 5.313        ­   
Total =    62,130  Total =       ­   

Page 1 of 9
Reinf Abut 1 03/15/2018
Project No: XXXXXXXX
Str. No.: X­XX­XXX
By: XXXXXXXXX
4  5  6  7  8  9  10  11 
BAR LIST - ABUTMENT 1 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

No.  Epoxy   Black   Epoxy   Black 


Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Abut. (Trans) E 11  4  56'­2"      224.67          ­        1,194        ­   
Abut. For App.(Trans) E 6  55  3'­0"      165.00          ­          248        ­   
Abut. (Trans) E 5  21  40'­0"      840.00          ­          876        ­   
Abut. (Trans) E 5  21  17'­8"      371.00          ­          387        ­   
Abut. Stirrups E 5  53  26'­11"    1,426.58          ­        1,488        ­   
Abut. Stirrups E 5  4  30'­9"      123.00          ­          128        ­   
Abut. into Appr Slab E 6  55  3'­0"      165.00          ­          248        ­   
Corbel Stirrups E 6  55  3'­9"      206.25          ­          310        ­   
Wingwall Stirrups E 4  19  22'­4"      424.33          ­          283        ­   
Wingwall (Long) E 7  14  17'­10"      249.67          ­          510        ­   
Wingwall (Long) E 7  14  16'­10"      235.67          ­          482        ­   
Wingwall (Vert) E 5  10  10'­11"      109.17          ­          114        ­   
Wingwall Stirrups E 6  28  7'­0"      196.00          ­          294        ­   
Wingwall (Long) E 9  4  17'­9"       71.00          ­          241        ­   
Wingwall Stirrups E 6  14  6'­4"       88.67          ­          133        ­   
Wingwall outside(Long) E 4  7  16'­4"      114.33          ­           76        ­   
Wingwall outside(Long) E 4  7  15'­10"      110.83          ­           74        ­   

Disclaimer BAR SUMMARY - ABUTMENT 1


Notice of Disclaimer: The Colorado Department of EPOXY COATED NON-EPOXY COATED
Transportation (CDOT) makes these documents
available on an "as is" basis. All warranties and
representations of any kind with regard to said Number Lbs. / Number Lbs. /
documents are disclaimed, including the implied of Lin. Bar Lin. of Lin. Bar Lin.
warranties of merchantability and fitness for a Ft. Size Ft. Weight Ft. Size Ft. Weight
particular use. Under no circumstances will the CDOT,
or any of its officers or employees be liable for any 33       649.50  #4 0.668        434          ­    #4 0.668        ­   
consequential, incidental, special or exemplary 109     2,869.75  #5 1.043      2,993          ­    #5 1.043        ­   
damages even if apprised of the likelihood of such 207       820.92  #6 1.502      1,233          ­    #6 1.502        ­   
damages occurring. The CDOT does not warrant the 28       485.33  #7 2.044        992          ­    #7 2.044        ­   
documents against deficiencies of any kind. The use 0          ­    #8 2.670        ­            ­    #8 2.670        ­   
of any of these documents for work which is under 4        71.00  #9 3.400        241          ­    #9 3.400        ­   
contract with the CDOT, does not relieve the
0          ­    #10 4.303        ­            ­    #10 4.303        ­   
contractor from any obligations assumed by the
contract, or from complete and proper fulfillment of 0       224.67  #11 5.313      1,194          ­    #11 5.313        ­   
the terms of the contract, nor does it entitle the Total =     7,087  Total =       ­   
contractor to compensation for damages or loss
which could be attributed to such use.

Page 2 of 9
Reinf Pier 2 03/15/2018
Project No: XXXXXXXX
Str. No.: X­XX­XXX
By: XXXXXXXXX
4  5  6  7  8  9  10  11 
BAR LIST - PIER 2 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

No.  Epoxy   Black   Epoxy   Black 


Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Pier Cap 11  6  53'­3" Str.         ­         319.50        ­        1,698 
Pier Cap 11  4  52'­6" Str.         ­         210.00        ­        1,116 
Pier Cap 11  4  50'­5" Str.         ­         201.67        ­        1,071 
Pier Cap 5  4  8'­3"         ­          33.00        ­           34 
Pier Cap 5  6  40'­0" Str.         ­         240.00        ­          250 
Pier Cap 5  6  11'­9" Str.         ­          70.50        ­           74 
Pier Cap 5  6  8'­3"         ­          49.50        ­           52 
Pier Diaphragm (Long) E 6  107  6'­1" Stirr.      650.92          ­          978        ­   
Pier Cap Stirrups 5  2  17'­10" Stirr.         ­          35.67        ­           37 
Pier Cap Stirrups 5  2  16'­10" Stirr.         ­          33.67        ­           35 
Pier Cap Stirrups 5  101  18'­4" Stirr.         ­       1,851.67        ­        1,931 
Column 8  15  11'­8" Str.         ­         175.00        ­          467 
Column Spiral 4  13  7'­10"         ­         101.83        ­           68 

Disclaimer BAR SUMMARY - PIER 2


Notice of Disclaimer: The Colorado Department of EPOXY COATED NON-EPOXY COATED
Transportation (CDOT) makes these documents
available on an "as is" basis. All warranties and
representations of any kind with regard to said Number Lbs. / Number Lbs. /
documents are disclaimed, including the implied of Lin. Bar Lin. of Lin. Bar Lin.
warranties of merchantability and fitness for a Ft. Size Ft. Weight Ft. Size Ft. Weight
particular use. Under no circumstances will the CDOT, or
any of its officers or employees be liable for any 13          ­    #4 0.668        ­         101.83  #4 0.668         68 
consequential, incidental, special or exemplary damages 127          ­    #5 1.043        ­       2,314.00  #5 1.043      2,414 
even if apprised of the likelihood of such damages 107       650.92  #6 1.502        978          ­    #6 1.502        ­   
occurring. The CDOT does not warrant the documents 0          ­    #7 2.044        ­            ­    #7 2.044        ­   
against deficiencies of any kind. The use of any of these 15          ­    #8 2.670        ­         175.00  #8 2.670        467 
documents for work which is under contract with the
CDOT, does not relieve the contractor from any 0          ­    #9 3.400        ­            ­    #9 3.400        ­   
obligations assumed by the contract, or from complete 0          ­    #10 4.303        ­            ­    #10 4.303        ­   
and proper fulfillment of the terms of the contract, nor 8          ­    #11 5.313        ­         731.17  #11 5.313      3,885 
does it entitle the contractor to compensation for Total =       978  Total =     6,833 
damages or loss which could be attributed to such use.

Page 3 of 9
Reinf Pier 3 03/15/2018
Project No: XXXXXXXX
Str. No.: X­XX­XXX
By: XXXXXXXXX
4  5  6  7  8  9  10  11 
BAR LIST - PIER 3 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

No.  Epoxy   Black   Epoxy   Black 


Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Pier Cap 11  6  53'­3" Str.         ­         319.50        ­        1,698 
Pier Cap 11  4  52'­6" Str.         ­         210.00        ­        1,116 
Pier Cap 11  4  50'­5" Str.         ­         201.67        ­        1,071 
Pier Cap 5  4  8'­3"         ­          33.00        ­           34 
Pier Cap 5  6  40'­0" Str.         ­         240.00        ­          250 
Pier Cap 5  6  11'­9" Str.         ­          70.50        ­           74 
Pier Cap 5  6  8'­3"         ­          49.50        ­           52 
Pier Diaphragm (Long) E 6  107  6'­1" Stirr.      650.92          ­          978        ­   
Pier Cap Stirrups 5  2  17'­10" Stirr.         ­          35.67        ­           37 
Pier Cap Stirrups 5  2  16'­10" Stirr.         ­          33.67        ­           35 
Pier Cap Stirrups 5  101  18'­4" Stirr.         ­       1,851.67        ­        1,931 
Column 8  15  11'­2" Str.         ­         167.50        ­          447 
Column Spiral 4  13  7'­10"         ­         101.83        ­           68 

Disclaimer BAR SUMMARY - PIER 3


Notice of Disclaimer: The Colorado Department of EPOXY COATED NON-EPOXY COATED
Transportation (CDOT) makes these documents
available on an "as is" basis. All warranties and
representations of any kind with regard to said Number Lbs. / Number Lbs. /
documents are disclaimed, including the implied of Lin. Bar Lin. of Lin. Bar Lin.
warranties of merchantability and fitness for a Ft. Size Ft. Weight Ft. Size Ft. Weight
particular use. Under no circumstances will the CDOT,
or any of its officers or employees be liable for any 13          ­    #4 0.668        ­         101.83  #4 0.668         68 
consequential, incidental, special or exemplary 127          ­    #5 1.043        ­       2,314.00  #5 1.043      2,414 
damages even if apprised of the likelihood of such 107       650.92  #6 1.502        978          ­    #6 1.502        ­   
damages occurring. The CDOT does not warrant the 0          ­    #7 2.044        ­            ­    #7 2.044        ­   
documents against deficiencies of any kind. The use of 15          ­    #8 2.670        ­         167.50  #8 2.670        447 
any of these documents for work which is under
contract with the CDOT, does not relieve the 0          ­    #9 3.400        ­            ­    #9 3.400        ­   
contractor from any obligations assumed by the 0          ­    #10 4.303        ­            ­    #10 4.303        ­   
contract, or from complete and proper fulfillment of 8          ­    #11 5.313        ­         731.17  #11 5.313      3,885 
the terms of the contract, nor does it entitle the Total =       978  Total =     6,813 
contractor to compensation for damages or loss
which could be attributed to such use.

Page 4 of 9
Reinf Pier 12 03/15/2018
Project No: XXXXXXXX
Str. No.: X­XX­XXX
By: XXXXXXXXX
4  5  6  7  8  9  10  11 
BAR LIST - PIER 3 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

No.  Epoxy   Black   Epoxy   Black 


Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Pier Cap 11  6  53'­3" Str.         ­         319.50        ­        1,698 
Pier Cap 11  4  52'­6" Str.         ­         210.00        ­        1,116 
Pier Cap 11  4  50'­5" Str.         ­         201.67        ­        1,071 
Pier Cap 5  4  8'­3"         ­          33.00        ­           34 
Pier Cap 5  6  40'­0" Str.         ­         240.00        ­          250 
Pier Cap 5  6  11'­9" Str.         ­          70.50        ­           74 
Pier Cap 5  6  8'­3"         ­          49.50        ­           52 
Pier Diaphragm (Long) E 6  107  6'­1" Stirr.      650.92          ­          978        ­   
Pier Cap Stirrups 5  2  17'­10" Stirr.         ­          35.67        ­           37 
Pier Cap Stirrups 5  2  16'­10" Stirr.         ­          33.67        ­           35 
Pier Cap Stirrups 5  101  18'­4" Stirr.         ­       1,851.67        ­        1,931 
Column 8  15  11'­2" Str.         ­         167.50        ­          447 
Column Spiral 4  13  7'­10"         ­         101.83        ­           68 

Disclaimer BAR SUMMARY - PIER 3


Notice of Disclaimer: The Colorado Department of EPOXY COATED NON-EPOXY COATED
Transportation (CDOT) makes these documents
available on an "as is" basis. All warranties and
representations of any kind with regard to said Number Lbs. / Number Lbs. /
documents are disclaimed, including the implied of Lin. Bar Lin. of Lin. Bar Lin.
warranties of merchantability and fitness for a Ft. Size Ft. Weight Ft. Size Ft. Weight
particular use. Under no circumstances will the CDOT,
or any of its officers or employees be liable for any 13          ­    #4 0.668        ­         101.83  #4 0.668         68 
consequential, incidental, special or exemplary 127          ­    #5 1.043        ­       2,314.00  #5 1.043      2,414 
damages even if apprised of the likelihood of such 107       650.92  #6 1.502        978          ­    #6 1.502        ­   
damages occurring. The CDOT does not warrant the 0          ­    #7 2.044        ­            ­    #7 2.044        ­   
documents against deficiencies of any kind. The use 15          ­    #8 2.670        ­         167.50  #8 2.670        447 
of any of these documents for work which is under
contract with the CDOT, does not relieve the 0          ­    #9 3.400        ­            ­    #9 3.400        ­   
contractor from any obligations assumed by the 0          ­    #10 4.303        ­            ­    #10 4.303        ­   
contract, or from complete and proper fulfillment of 8          ­    #11 5.313        ­         731.17  #11 5.313      3,885 
the terms of the contract, nor does it entitle the Total =       978  Total =     6,813 
contractor to compensation for damages or loss
which could be attributed to such use.

Page 5 of 9
Reinf Abut 13 03/15/2018
Project No: XXXXXXXX
Str. No.: X­XX­XXX
By: XXXXXXXXX
4  5  6  7  8  9  10  11 
BAR LIST - ABUTMENT 13 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

Phase 1 Construction
No.  Epoxy   Black   Epoxy   Black 
Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Abut. (Trans) E 11  6  36'­0"      216.00          ­        1,148        ­   
Abut. (Trans) E 5  18  27'­2"      489.00          ­          510        ­   
Abut. (Trans) E 5  12  6'­4"       76.00          ­           79        ­   
Abut. (Trans) E 5  2  24'­7"       49.17          ­           51        ­   
Abut. Stirrups E 5  27  43'­2"    1,165.50          ­        1,216        ­   
Abut. into Appr Slab E 6  26  3'­0"       78.00          ­          117        ­   
Wingwall Stirrups E 4  10  32'­5"      324.17          ­          217        ­   
Wingwall (Long) E 4  11  16'­3"      178.75          ­          119        ­   
Wingwall (Long) E 7  21  17'­9"      372.75          ­          762        ­   
Wingwall (Vert) E 5  5  15'­10"       79.17          ­           83        ­   
Wingwall Stirrups E 5  11  6'­10"       75.17          ­           78        ­   
Wingwall (Long) E 9  2  17'­10"       35.67          ­          121        ­   

BAR SUMMARY - ABUTMENT 13


EPOXY COATED NON-EPOXY COATED

Number Lbs. / Number Lbs. /


of Lin. Bar Lin. of Lin. Bar Lin.
Ft. Size Ft. Weight Ft. Size Ft. Weight

21       502.92  #4 0.000        336          ­    #4 0.000        ­   


75     1,934.00  #5 0.000      2,017          ­    #5 0.000        ­   
26        78.00  #6 0.000        117          ­    #6 0.000        ­   
21       372.75  #7 0.000        762          ­    #7 0.000        ­   
0          ­    #8 0.000        ­            ­    #8 0.000        ­   
2        35.67  #9 0.000        121          ­    #9 0.000        ­   
0          ­    #10 0.000        ­            ­    #10 0.000        ­   
6       216.00  #11 0.000      1,148          ­    #11 0.000        ­   
Total =     4,501  Total =       ­   

BAR LIST - ABUTMENT 13 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 
Phase 2 Construction
No.  Epoxy   Black   Epoxy   Black 
Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Abut. (Trans) E 11  6  22'­8"      136.00          ­          723        ­   
Abut. (Trans) E 5  16  22'­8"      362.67          ­          378        ­   
Abut. (Trans) E 5  6  6'­4"       38.00          ­           40        ­   
Abut. (Trans) E 5  2  10'­1"       20.17          ­           21        ­   

Page 6 of 9
Reinf Abut 13 03/15/2018
Abut. Stirrups E 5  24  43'­2"    1,036.00          ­        1,081        ­   
Abut. into Appr Slab E 6  23  3'­0"       69.00          ­          104        ­   
Wingwall Stirrups E 4  10  23'­4"      233.33          ­          156        ­   
Wingwall (Long) E 4  8  16'­8"      133.33          ­           89        ­   
Wingwall (Long) E 7  15  17'­9"      266.25          ­          544        ­   
Wingwall (Vert) E 5  5  11'­4"       56.67          ­           59        ­   
Wingwall Stirrups E 5  8  6'­10"       54.67          ­           57        ­   
Wingwall (Long) E 9  2  17'­11"       35.83          ­          122        ­   
Wingwall Stirrups E 5  8  6'­11"       55.33          ­           58        ­   

Disclaimer BAR SUMMARY - ABUTMENT 13


Notice of Disclaimer: The Colorado Department of EPOXY COATED NON-EPOXY COATED
Transportation (CDOT) makes these documents
available on an "as is" basis. All warranties and
representations of any kind with regard to said Number Lbs. / Number Lbs. /
documents are disclaimed, including the implied of Lin. Bar Lin. of Lin. Bar Lin.
warranties of merchantability and fitness for a Ft. Size Ft. Weight Ft. Size Ft. Weight
particular use. Under no circumstances will the CDOT,
or any of its officers or employees be liable for any      366.67  #4 0.668        245          ­    #4 0.668        ­   
consequential, incidental, special or exemplary    1,623.50  #5 1.043      1,693          ­    #5 1.043        ­   
damages even if apprised of the likelihood of such       69.00  #6 1.502        104          ­    #6 1.502        ­   
damages occurring. The CDOT does not warrant the      266.25  #7 2.044        544          ­    #7 2.044        ­   
documents against deficiencies of any kind. The use         ­    #8 2.670        ­            ­    #8 2.670        ­   
of any of these documents for work which is under
contract with the CDOT, does not relieve the       35.83  #9 3.400        122          ­    #9 3.400        ­   
contractor from any obligations assumed by the         ­    #10 4.303        ­            ­    #10 4.303        ­   
contract, or from complete and proper fulfillment of      136.00  #11 5.313        723          ­    #11 5.313        ­   
the terms of the contract, nor does it entitle the Total =     3,430  Total =       ­   
contractor to compensation for damages or loss
which could be attributed to such use. Grand Total =    7,932 

Page 7 of 9
Reinf Approach Slabs 03/15/2018
Project No: XXXXXXXX
Str. No.: X­XX­XXX
By: XXXXXXXXX
4  5  6  7  8  9  10  11 
BAR LIST - APPROACH SLAB ABUTMENT 1 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

No.  Epoxy   Black   Epoxy   Black 


Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Slab (Top Long) E 4  10  50'­8"      506.67          ­          338        ­   
Slab (Top Long) E 4  18  33'­1"      595.50          ­          398        ­   
Slab (Bottom Long) E 9  89  36'­0"    3,204.00          ­       10,894        ­   
Slab (Top & Bot Trans) E 5  56  21'­1"    1,180.67          ­        1,231        ­   
Slab (Top & Bot Trans) E 5  46  40'­0"    1,840.00          ­        1,919        ­   
Slab (Top & Bot Trans) E 5  46  5'­2"      237.67          ­          248        ­   
Slab (Top & Bot Trans) E 5  2  3'­9"        7.50          ­            8        ­   
Slab (Top & Bot Trans) E 5  2  2'­4"        4.67          ­            5        ­   
Slab Stirrups E 5  53  7'­8"      406.33          ­          424        ­   
Slab (Bottom Long) E 5  2  40'­0"       80.00          ­           83        ­   
Slab (Bottom Long) E 5  2  14'­3"       28.50          ­           30        ­   
Sleeper at conduit E 5  4  3'­8"       14.67          ­           15        ­   
Sleeper at conduit E 5  4  8'­2"       32.67          ­           34        ­   
Sleeper Trans E 5  8  40'­0"      320.00          ­          334        ­   
Sleeper Trans E 5  8  5'­2"       41.33          ­           43        ­   
Sleeper Stirrups E 5  45  15'­8"      705.00          ­          735        ­   
Disclaimer
Notice of Disclaimer: The Colorado Department of
Transportation (CDOT) makes these documents available
on an "as is" basis. All warranties and representations of BAR SUMMARY - APPROACH SLAB ABUTMENT 1
any kind with regard to said documents are disclaimed, EPOXY COATED NON-EPOXY COATED
including the implied warranties of merchantability and
fitness for a particular use. Under no circumstances will
the CDOT, or any of its officers or employees be liable for Number Lbs. / Number Lbs. /
any consequential, incidental, special or exemplary of Lin. Bar Lin. of Lin. Bar Lin.
damages even if apprised of the likelihood of such Ft. Size Ft. Weight Ft. Size Ft. Weight
damages occurring. The CDOT does not warrant the
documents against deficiencies of any kind. The use of 28     1,102.17  #4 0.668        736          ­    #4 0.668        ­   
any of these documents for work which is under 278     4,899.00  #5 1.043      5,110          ­    #5 1.043        ­   
contract with the CDOT, does not relieve the contractor 0          ­    #6 1.502        ­            ­    #6 1.502        ­   
from any obligations assumed by the contract, or from 0          ­    #7 2.044        ­            ­    #7 2.044        ­   
complete and proper fulfillment of the terms of the 0          ­    #8 2.670        ­            ­    #8 2.670        ­   
contract, nor does it entitle the contractor to 89     3,204.00  #9 3.400     10,894          ­    #9 3.400        ­   
compensation for damages or loss which could be 0          ­    #10 4.303        ­            ­    #10 4.303        ­   
attributed to such use.
0          ­    #11 5.313        ­            ­    #11 5.313        ­   
Total =    16,740  Total =       ­   

BAR LIST - APPROACH SLAB ABUTMENT 13 0.668  1.043  1.502  2.044  2.670  3.400  4.303  5.313 

Page 8 of 9
Reinf Approach Slabs 03/15/2018

No.  Epoxy   Black   Epoxy   Black 


Bar No. Req'd Dimensions  Total   Total   Total   Total 
Description Size Req'd B.E.I Length Type A B C  Length   Length   Weight   Weight 
Slab (Top Long) E 4  10  50'­8"      506.67          ­          338        ­   
Slab (Top Long) E 4  18  33'­1"      595.50          ­          398        ­   
Slab (Bottom Long) E 9  88  36'­0"    3,168.00          ­       10,771        ­   
Slab (Top & Bot Trans) E 5  56  21'­1"    1,180.67          ­        1,231        ­   
Slab (Top & Bot Trans) E 5  46  40'­0"    1,840.00          ­        1,919        ­   
Slab (Top & Bot Trans) E 5  46  5'­2"      237.67          ­          248        ­   
Slab (Top & Bot Trans) E 5  2  3'­9"        7.50          ­            8        ­   
Slab (Top & Bot Trans) E 5  2  2'­4"        4.67          ­            5        ­   
Slab Stirrups E 5  53  7'­8"      406.33          ­          424        ­   
Slab (Bottom Long) E 5  2  40'­0"       80.00          ­           83        ­   
Slab (Bottom Long) E 5  2  14'­3"       28.50          ­           30        ­   
Sleeper at conduit E 5  4  3'­8"       14.67          ­           15        ­   
Sleeper at conduit E 5  4  8'­2"       32.67          ­           34        ­   
Sleeper Trans E 5  8  40'­0"      320.00          ­          334        ­   
Sleeper Trans E 5  8  5'­2"       41.33          ­           43        ­   
Sleeper Stirrups E 5  45  15'­8"      705.00          ­          735        ­   

Disclaimer
Notice of Disclaimer: The Colorado Department of
Transportation (CDOT) makes these documents available
on an "as is" basis. All warranties and representations of
any kind with regard to said documents are disclaimed,
including the implied warranties of merchantability and BAR SUMMARY - APPROACH SLAB ABUTMENT 13
fitness for a particular use. Under no circumstances will EPOXY COATED NON-EPOXY COATED
the CDOT, or any of its officers or employees be liable for
any consequential, incidental, special or exemplary
damages even if apprised of the likelihood of such Number Lbs. / Number Lbs. /
damages occurring. The CDOT does not warrant the of Lin. Bar Lin. of Lin. Bar Lin.
documents against deficiencies of any kind. The use of Ft. Size Ft. Weight Ft. Size Ft. Weight
any of these documents for work which is under contract
with the CDOT, does not relieve the contractor from any    1,102.17  #4 0.668        736          ­    #4 0.668        ­   
obligations assumed by the contract, or from complete    4,899.00  #5 1.043      5,110          ­    #5 1.043        ­   
and proper fulfillment of the terms of the contract, nor         ­    #6 1.502        ­            ­    #6 1.502        ­   
does it entitle the contractor to compensation for         ­    #7 2.044        ­            ­    #7 2.044        ­   
damages or loss which could be attributed to such use.         ­    #8 2.670        ­            ­    #8 2.670        ­   
   3,168.00  #9 3.400     10,771          ­    #9 3.400        ­   
        ­    #10 4.303        ­            ­    #10 4.303        ­   
        ­    #11 5.313        ­            ­    #11 5.313        ­   
Total =    16,617  Total =       ­   

Page 9 of 9

You might also like