You are on page 1of 22
PROCESS INDUSTRY PRACTICES VE FV1 1 20M Ib FABRICATION/INSTALLATION DETAILS Voie wnt cea Z feared. PIPE. SUPPORTS as ATTACHED TO VESSELS vennIODr Tye, ALL U B 7B z 127, mad 38 CLIP_ANGLE a io i / BieSes oy © ao y 5 OTHERS) 2 a 49 = § TH | Ty wl a) aff 4 10 \ 5 \ J c 8 x2 x 207 = Laxey } YP. ALL 64 X 10 THK. see nore 1S 0 7c SMPFENER PLATE ann Te AL TYPE _3 — SUPPORT $ zie HOLES FOR 3/4" 7 SFR: PL BOLTS WITH SQUARE HEADS AND NUTS ASTM A525, PLAN FOR TYPE 1, 2 & 3 SUPPORTS LEGEND 5 TSE] MAX. ALLOW, LINEAL METERS OF PIPE FILLED WITH WATER i kg] SUPPORT WEIGHT INCLUDING ANGLE CUPS WEIGHTS SHOWN IN TABLES ARE NET FABRICATED WEIGHTS FOR ESTMATING PURPOSES. ALL OMENSIONS ARE IN mm UNLESS NOTED OTHERWISE pipe size [ 8" [ 10"[ 12"[ 14°] te] 18]. FOR GENERAL NoTES,|__ SCHEDULE [4080/40] 60/40] 60|40[ 60/30] 60] 30] 60] -, SEE VEFVI120, PAGE | = [556] 42 [36 pe.s[z4s[z2ahreshiezhashiss[ia] % 3 S| | 30532 ig [35 tg | Sg | 30 kg | a2 eg | 4 ng | old |Z 58.2]46.3]36.5]31.3| 25 [21.3|20.1]17 3] tet izes] 97] B | S395[ ssa | 38 te [ad ke | Ske | ab ko | a7 kg | > es |Z 51.2]40.5| 32 [27.4)z2.2]16.8] v6 [15.5|14.6]11.2| 18.8] Go S\E | S406 se ag [aig | ae ng [a5 ke | aug [SOK | Oo Flg |2 48.4] 36 | 29 [246[201] 17 [76.1] 14 [is.s}ios[97[ Bo & 2 457g [ag ag wee | ste | a] SS & |b 7 ws[sze|z2)e27|es|oa| te [8[eifsapai75] = |* S08) aig [a7 ug | 50 ko | Sikg | 559 | 87 PLAN VIEW DIMENSIONS PIPE_SIZE 2 Ts Tee Ta Tot 12", a" eT 18" CUP_ANGLE 3” X 2° X 3/8" (FURNISHED BY OTHERS)- SHIP LOOSE, FIELD WELD TO PIPE A 7% | 7% | % | 7% | a | @& | #5 | os | os | os B vo | 9 [| 108 | 150 | 190 | 230 | 265 | 265 | 325 | 305 C (SEE NOTE 3)/ 225 | 254 | 200 | 335 | 300 | a50 | soo | sas | sas | oss | PROCESS INDUSTRY PRACTICES VEFV1120M y FABRICATION/INSTALLATION DETAILS ISSUED: JUNE 109 ATTACHED TO VESSELS VEFVITOOM —Y h ~ : mn | He lg i T z Un nt t q SN see note 1 a a TYPE 4 — SUPPORT DESIGN TO SUIT CONDITIONS L 3" X 2" X 1/4" (MAX. LOAD OF USE DOUBLE ANGLES FOR KNEE BRACES 900% FOR 305 "L" DIMN.) AS REQUIRED. TYPE_5 — SUPPORT FOR 1 NOTES: 1. VESSEL CUP OR PAD MATERIAL WELDED DIRECTLY TO VESSEL SHALL BE THE SAME AS THE MATERIAL TO WHICH IT TS WELDED, REINFORCEMENT PADS SHALL BE PROVIDED FOR LOAD DISTRIBUTION FOR THIN WALL VESSELS. PADS, IF USED, SHALL BE THE SAME THICKNESS AS THE SHELL IF POSSIBLE. EACH PAD SHALL HAVE A 1/4" NPT HOLE FOR VENTING / TESTING. 2. STRUCTURAL MEMBERS SHALL HAVE A MINIMUM YIELD STRENGTH OF 36 ki ‘3. DIMENSION “C” IS FOR UNINSULATED PIPE. IF REQUIRED, DIMENSION “C" SHALL BE AD.USTED TO INCLUDE INSULATION ‘THICKNESS. IF INSULATION IS REQUIRED, ADJUST “"C" DIMENSION BY INSULATION THICKNESS X 2 4 THE THICKNESSES AND DIMENSIONS SHOWN ARE SUGGESTED STARTING VALUES FOR ALL PIPE SUPPORTS. REQUIRED THICKNESSES AND DIMENSIONS SHALL BE CALCULATED USING THE APPLICABLE DESIGN LOADS. ‘5, FOR INSULATED VESSELS, THE DIMENSION SHOWN BETWEEN THE OUTSIDE OF THE INSULATION AND PIPE SUPPORT CLIP BOLTING SHALL BE CHECKED TO ASSURE THAT PPE SUPPORT BRACKET AND BOLTING CLEAR OUTSIDE OF INSULATION, BASED ON SUPPORT MEMBER SIZE, BOLT SIZE AND WRENCH DIAMETER CLEARANCE, 6, SEE VESSEL OR LADDER AND PLATFORM ORAMING/DATA SHEET FOR ACTUAL DIMENSIONS. 7. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE. PROCESS INDUSTRY PRACTICES VEFV1121M FABRICATION/INSTALLATION DETAILS ISSUED: JUN AFFIRMED: J PIPE GUIDES PACE TOF 2 ATTACHED TO VESSELS VvERVITO0N Vv L/ OS, VESSEL a g OF INSULATION LU SEE NOTE 1 5 4 70100 38 ae ro t T a 64 X 13 BARS FOR TYPE 1 WY Pr 89 X13 BARS FOR NPE 2 TYPE 1 & 2 FOR GENERAL NOTES SEE VEFVI121M, PAGE 2 MAXIMUM GUIDE SPACING ls |x IL" DIMENSION — SEE NOTE 1 | 5 oesl cose) aos] coasy soo tesoo neta Lnesol ia Fel S[ eo | oo | oo | eo | oo | oo | se | so | so rps }s fs [ss an] ae [se [se [ae | a8 plese [54 | sa | sa | 54 Efs[ ve [76 [76 | 76 | 76 efer [er [ar [er | as ef vai | vas | van | a1 | vas | ven | ren | ven | ver | vas welis7 ps7 por ps7 [er per per [er [er | er £ 1o"| 16.7 | 16.7 | 167 | 167 | 167 | 167 | 16.7 | 167 | 16.7 | 16.7 w| tea [sea | 182 | v2 | ve2 | ve2 | v67 | 152 | 152 | 37 REAFFIRNED: JAN 2009 PIPE GUIDES PAGE 2 OF 2 PROCESS INDUSTRY PRACTICES VEFV1121M ID i) FABRICATION/INSTALLATION DETAILS ISSUED: JUNE 1999 Z Z ATTACHED TO VESSELS vERViTOON SEPARATORS PIPE CLAMPS OS. VESSEL SIZED T0 PERMIT 3 CLEARANCE on Pipe FoR SUE FIT = " El ‘OP & 5 7 SIDES ONLY 5 "LY SEE NOTE 1 3 38 10 | 70 {nore 5) ~. xe! 2 TY t oe J arxis ruse TYPE 3 SEE ELEVATION NOTES: SEE VESSEL OR LADDER AND PLATFORM DRAWNG/DATA SHEET FOR ACTUAL “L" DIMENSION, ORIENTATION AND ELEVATION, VESSEL CLIP MATERIAL SHALL BE THE SAME AS THE MATERIAL TO WHICH IT IS WELDED. SHALL BE PROVIDED FOR ALLOY VESSELS, A POISON PAD IS OPTIONAL REINFORCEMENT PADS SHALL BE PROVIDED FOR LOAD DISTRIBUTION REINFORCNENT PADS ARE REQUIRED FOR LOAD DISTRISUTION FOR THIN WALL VESSELS. PADS, IF USED, SHALL BE THE SAME ALLOY AS THE VESSEL AND OF THE SAME THICKNESS AS THE SHELL IF POSSIBLE. EACH PAD SHALL HAVE 1/4" NPT HOLE FOR VENTING/TESTING BOLT HOLES SHALL BE 21 DIA. FOR 3/4” DIA. ASTM A325 HEAVY HEX HEAD BOLTS WITH HEAVY HEX NUTS. UNLESS OTHERWISE SPECIFIED, ALL NECESSARY BARS, PLATES, CHANNELS AND BOLTNG SHALL BE PROVIDED, FOR INSULATED VESSELS, THE DIMENSION SHOWN BETWEEN THE QUTSIDE OF THE OUTSIDE OF THE INSULATION AND PIPE SUPPORT CLIP BOLTING SHALL BE CHECKED TO ASSURE THAT PIPE SUPPORT BRACKET AND BOLTING CLEAR OUTSIDE OF INSULATION, BASED ON SUPPORT MEWGER SIZE, BOLT SIZE, AND WRENCH DIAMETER CLEARANCE, ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE. STRUCTURAL MENGERS SHALL HAVE A MINIMUM YIELD STRENGTH OF 36 KS. Sul i MAXIMUM GUIDE SPACING #aly "LY DIMENSION — SEE NOTE 1 e's 2406] L=457 560] tera | 1=760 » fe| as [as | as | vez | 67 [32 137 [| 121 | ta g [refs [ie [rer [ver [sz [ta7 [vas [v2 [08 | 08 wl 198 | 167 | 182 | 137 | 21 | 121 [18 | 6 | or [ an PROCESS INDUSTRY PRACTICES VEFV1122M FABRICATION/INSTALLATION DETAILS ISSUED: UNE fast REAFFIRMED: Jah VESSEL HORIZONTAL INSULATION SUPPORTS | PACE 1 oF vErViTOOM | ‘SEE DETAIL \ al PEQUALLY SPACE SEE OETAL "8 ‘SPACER RODS (40 waxMUM) Ht 25 ra SEE DETAL * \ Ve DETAIL TL yotrs 1. HORIZONTAL SUPPORT SHALL BE PROVIDED wee FOR VESSELS 2450 DIAMETER AND LARGER. SEE DETAIL 2.SEE_VESSEL DRAWNG/DATA SHEET FOR MATERIAL SLALL DIMENSIONS ARE IN mm UNLESS SIDE MEW _ NOTED OTHERWISE. INSUL, THK, MINUS 13 see oeTat “4 EQUALLY SPACE r LEP onan Sees — ¢ HORIZONTAL SUP'T. & SPACER RODS 3 DETAIL 10 DIA. ROUND BAR ae TYP. ¢ HORIZONTAL SUP'T me & SPACER RODS os, Nozze Ne L-[ Neck 10 DIA, G'S. ROD FLOATING RING. DETAIL “B” 10 DIA. ROD SHALL BE TIED OFF FOR SHIPMENT, END VIEW. PROCESS INDUSTRY PRACTICES VEFV1123M FABRICATION/INSTALLATION DETAILS ISSUED: JUNE 1999 REAFFIRNED: JAN 200 VERTICAL VESSEL INSULATION PACE TOFS AND FIREPROOFING SUPPORTS VvERVITO0N SEE DETAL “AT (vervii23, PAGE 2) HEAD SEAM. ce jo se ome ara. nce 2) SET CRUE AES Z| SEE DETAIL "8" (VEFVII23, PAGE 2) OR 3 STP TYPE 2 oR 3 (VEFVII23, PAGE 5) LUG SHALL BE MODIFIED AAS REQUIRED TO CLEAR SEAM. wiv LL. DETAIL °F" (VEFVI123, PAGE 2) OR "Y" TYPE 1 (VEFVII23, PAGE 5) SEE DETAIL "8" (VEFVII23, PAGE 2) oR “S TYPE 2 oR 3 (VEFVIIZ3, PAGE 5) ‘SEE DETAIL "E", "F" OR, “G", (VEFVIIZS, PAGE 3), “H" (VEFVIIZ3, PAGE 4), O8 “D" (VEFVII23, PAGE 2) ‘3700 MAX. TYP. \ 7 Tu. oh Giervies, Pace) FIREPROOF AROUND LUGS ‘TO BTM. OF BASE RING 1/2 SQUARE NUTS OR STUDS SPACED ON 460 CENTERS L IN BOTH DIRECTIONS FOR FIREPROOFING; INSTALL IN SHOP, 1 ' ' ' | see ceva "E” on “F° ' ' NOTES. 1. SEE VESSEL DRAMING/DATA SHEET FOR MATERIAL. 2.ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE. PROCESS INDUSTRY PRACTICES VEFV1123M y i) FABRICATION/INSTALLATION DETAILS ISSUED: NE Z Z REAFFIRNED: JAN 20) VERTICAL VESSEL INSULATION PAGE 2 OF AND FIREPROOFING SUPPORTS vErRViTOON —Fuasce gout Cente OS 25 (MIN.) 10 = 7 2 eK. ANste on ~~ PLATE W/ 25 ’ Enron” es ze Belo wsut. aig winvs 13 Fe 10 018, c's. g00 Ponts ins DETAIL “A” 10 014, R00 SHALL Be TED-OFF POR SHPMENT. os. HEAD 10 DIA. cS. ROD TACK WELD HEAD To SHELL oo 7 THK X 25 $0. SPACED ON 600 ade GENTERS (MAX) | 7 THK ANGLE OR PLATE Taw, INSULATION THK. PLUS 13 MIN. (rye. For 80TH ANGLE LEGS) DETAIL "C” NOTE: ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE OS. SHELL TINS TH, Mn 13 7 THK, CS. CONT. RING. (00 NOT WELD 10 THE LUG) SEE ELEY, 7 THK, PLATE SPACED ON APPROX {600 CENTERS DETAIL “8” 13 x 45° NOTCH FILL W/ wasmic WEATHER SEAL (BY OTHERS) DETAIL “D" FOR UNNSULATED VESSELS PROCESS INDUSTRY PRACTICES FABRICATION/INSTALLATION DE TAILS VEFV1123M ISSUED: JUNE VERTICAL VESSEL INSULATION AND FIREPROOFING SUPPORTS REAFFIRMED: PAGE SOF VvEFVII00N VERTICAL VESSEL WITH SKIRTS Te INSULATION 08 FIRE- PROOFING THICKNESS NO INSULATION 7 THK ANGLE x 50 INSULATION 108 ROUND BAR Wi25 STANDOFF CUPS TH INSULATION OR ARE tH Seco, ON 600 CENTERS PROOFING THICKNESS RED EaN, ee THY 7 Tk. CONTINUOUS RING INSULATION ANCHORS SPACED ON 600 CTRS ~~ j FIREPROOFING 10 DA, o8. 7 THK X 50 UG. x T MDE Ma Monte contmuous FLAT BAR SPACED ON APPROX ANG 500 CENTERS 40 PWS T DETAIL_“E” INSULATION N'600 ‘CENTERS XONSUL Ta, | su 12 cae Pr Noe os gop | WH. 25, STANO-CFF |g /J Wy. 25, STA jio* ROUND BAR W/ 125. STAND-OFF ‘CUPS |$2c’0. ON 600 TRS. (ONE PER LAYER) INSULATION, 10.GA, WELD PIN mee li! 1 Tek. 50 U6, XT WOE EAR ile AS WPbnox. |Loss 1 Sob cohen DETAIL “F” DETAIL _"G" — HOT BOX DESIGN VERTICAL VESSEL WITH SKIRTS VERTICAL VESSEL WITHOUT SKIRTS: 1. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE. PROCESS INDUSTRY PRACTICES VEFV1 1 23M FABRICATION/INSTALLATION. DETAILS See ne VERTICAL VESSEL. INSULATION cern AND FIREPROOFING. SUPPORTS aan —wcon Wee 10 94 noame nemneenoce (ONE PER LAYER) conn 4H i | | ke NOTE: — 108 ROUND BAR WIT 25. STANDOFF CLIPS 2 MEH Tene . Bee eS we ne ator ve | se nus peor SPORT NG yea Lvo ox, veto ow she noua ‘SUPPORT RING DETAIL “H” ‘ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERMISE. 00 CENTERS PROCESS INDUSTRY PRACTICES VEFV1123M FABRICATION/INSTALLATION DETAILS ISSUED: JUNE 1999 SEAPPRVED JAN 204 VERTICAL VESSEL INSULATION PAGES OF >[P AND FIREPROOFING SUPPORTS vErViTOON 10 (TYPE 1 & 2) 25 (PE 3) OS. HEAD 23 (NPE 1 & 2 (TE 3) | Gree 1&2) UPL! 35" x 7I SEE NOE | TYPE 1&2 TPES E40 10 | axuw SeoueNT Set. Sea LENG EQUALS TBS ' 10-(1YeE 4 & 2) | 7 (PE 3) \ t CUP L-2=1/2" x 2-1/2" x 3/8" ¢168 HOLE WN cuP AND 16 %_55.SLOT ‘ IN'RNG (EXCEPT CENTER Cu) FoR 1/2°8 BOLTS 1. CUPS SHALL BE LOCATED ON 915 MAXIMUM CENTERS FOR TYPE 1 WITH INSULATION THICKNESS UP’ TO 125 AND TYPE 2 WH INSULATION UP TO 100,” CLIPS SHALL BE LOCATED ON 600 MAXIMUM CENTERS FOR TYPE 1” WITH INSULATION THICKNESS. ABOVE 125. CLIPS SHALL BE LOCATED ON 460 MAXIMUM CENTERS FOR TYPE, 3 WITH INSULATION THICKNESS ABOVE 100." A MINIVUW. OF THREE CLIPS PER SEGMENT SHALL BE PROMIDED. RINGS SHALL BE LOCATED TO CLEAR VESSEL APPURTENANCES AND WELDS IF POSSIBLE. IF PRACTICABLE TO AVOID INTERFERENCE, A 25 MINIMUM CLEARANCE SHALL SE PROWDED. BETWEEN THE END OF THE RING. AND THE INTERFERING COMPONENT AND BETWEEN THE CLP ATTACHING WELDS AND VESSEL WELDS OR ATTACHING WELD OF ANY INTERFERING COMPONENT, ALL RING HOLES SHALL BE SLOTTED FoR SYPE 3 WIM THE SLOT AT THE CENTER OF THE CLIP HOLE. ALL CLI'S SHALL BE TURNED THE SAME OIRECTION. ALL MATERIAL WELDED TO VESSEL SHALL BE THE SAME MATERIAL AS THE VESSEL. ALL OTHER MATERIAL SHALL BE CARBON STEEL. we (ree 9 > WITH NUTS AND WASHERS SECTION “A=A” (NP) USE ODD NUMBER OF CLIPS: PER RING SEGMENT WITH 168 HOLE IN RING AT CENTER CUP. SEE NOTE 3 Os. SHEL 5 MN 10 (MIN.). SLOT RING AWAY FROM CENTER CLP he SLOTTED HOLES Senos” / 1 REQUIRED FOR 2 | 40 TYEE 1 ONLY INSULATION SUPPORT DESCRIPTIONS: ' “ae Seer OR, ‘ON CENTERS (TY.) TYPE 2 INTERMEDIATE SUPPORT FOR 215 wax INSULATION LESS THAN O8 SE NOE] BaUAN To 100, THK 7 TYPE 3+ INTERMEDIATE SUBPORT FOR “yt INSULATION GREATER DETAIL "J" ‘Nan 100 Tak INSULATION) 38 | 50 | 63] 75 | 88 | 100] 113] 125 | 138] 150] 163 | 175 | 188 | 200 | 213 | 225 | 238 | 250 ewes x [| @| | oa oa | | 7] oo | oo | co | co | oo | oo] 69 | vor | vo2| 102] sca] E-[ | se | 36 | sa | | | o7| 79] 92 | o2| 105] 117] 150] 156 | 156 | ves | vei | 194 | 200 sf wr | se | 38 | se | a | se | o7 SL | 7 | 7 | 08 | v02] va] vwo] wo) v62] 165] 176) var t 3 | e7 | o7 | 79 | 79 | 2 | 130) 130) 143] 156) 156] 168 é wf 2| 2] a] sf oe] | oof er| o7| PROCESS INDUSTRY PRACTICES FABRICATION/INSTALLATION DETAILS VEFV1124M ISSUED: JUNE 1999) REAFFIRWED: JAN PIP VESSEL VORTEX BREAKERS PAGE TOF 1 vErViTOOM } 2» re. > I t INSIDE soTTOM: HEAD o8 SHELL i, { 4 i L 0/2 (25 MIN.) | NOTE: COPE 10 CLEAR WELD FLUSH TYPE NOMINAL DIA, OF NOZZ, 3 PLUS CORR, ALLOW. “Tr = 3 PLUS 2(CORR. ALLOW) 2» = (4) BLADES: SECTION RT | OS INSIDE HEAD OR SHELL L 0/2 (25 MIN) 169 ORAIN HOLE NOTES. 7. SEE VESSEL DRAWING/DATA SHEET FOR INSIDE PROJECTION TYPE MATERIAL ANO BLADE REQUIREMENTS. 2. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE, PROCESS INDUSTRY PRACTICES VEFV1 4 25M iy FABRICATION /INSTALLATION. DETAILS Venlo ane VESSEL INTERNAL LADDERS PAGE OF caus mune REQUIRED UNLESS OTHERWISE SPECFED. qe] 4 b | | 3 ~ I £ ! _ sessiene | df. i ed r | oc | r ! |— 150 asove sorrow HEAD WELD ! LINE ‘Of 610 ABOVE DECK | VERTICAL VESSEL HORIZONTAL VESSEL by At OHS. 4 1. LADDER RUNS eLOW manny 4 SARITaE Provbes wee Some an Vester Rawnc/OarA Skeet Ox IF-THE DISTANCE. FROM THE CENTERUNE. OF THE MANWAY TO LONER HEAD OR TRAY DECK 1S GREATER THAN 1220, 2, SEE VESSEL DRAWNG/DATA SHEET FOR MATERIA 3. ALL DIMENSIONS ARE IN mm UNLESS 19 DIA, Bar NOTED' OTHERWISE UiNcLUbES CoRR. ALLOW.) INTERNAL LADDER RUNG OR GRAB RUNG PROCESS INDUSTRY PRACTICES VEFV1126M D> D FABRICATION/INSTALLATION DETAILS ISSUE nee Z ZY REAFFIRMED. JAN 2009 LOCKING STUDS FOR HEAT EXCHANGER — | aie 1 oF 1 REMOVABLE TUBESHEETS vervii000 TUBESHEET ‘GASKET SHELL SIDE Tee SIDE WRENCH FLATS THREADED COLLAR SEE DETAIL CCOUNTERSORE (FOR LockiNG STUDS ONLY) OVERALL LENGTH FIRST FULL THRO.) ‘SUITE LOCKING AE vot as WeeAD FLL LEN THREADED COLLAR LOCKING STUD MATERIAL AS STUD OR FROM HEX NUT LOGKING STUD HABA AS SN RO WE NOTES: \ Looene subs A WED Fon Use wD) RE 3 |(ads J abe | ee | ale | ain INS SRE SSE MINOR OO ENT So ers THE REMOVAL OF THE CHANNEL FOR INSPECTION AND ae 27 13 30 16 6 PROPERLY IN PLACE BEFORE PRESSURE TESTING THE 1-1/8" a 9 4&8 2 8 ‘SHELL SIDE. 11a" | 22 48 25 W CATIONS, LOCKING STUDS SHALL BE PROVIDED FOR EVERY 3/8 49 a4 82 a w 6. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE. 30 a 34 “ 22 PROCESS INDUSTRY PRACTICES ~ VEFV1127M ») FABRICATION/INSTALLATION DETAILS ISSUED: JUNE IS Z REAFFIRMED: JAN 2009 HEAT EXCHANGER FIXED TUBESHEET [Pee wor “I TT AND DRAIN vein —eroi pacen \ 198 DRILLING 2] -+—-—- —— —* | ayes Ney exass apo niger | SHELL SIDE NOTES: To THE MINIMUM TUBESHEET THICKNESS AT THE OUTER: RIM SHALL BE THE GREATER OF THE CALCULATED THICKNESS OR 50 2. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE, 3. CLASS 6000 THREDOLET SHALL BE USED IF TUBESHEET THICKNESS 1S GREATER THAN 60 FIRMED: 2008 SKIRT ATTACHMENTS PAGE TOF 5 = PROCESS INDUSTRY PRACTICES VEFV1128M | D) FABRICATION/INSTALLATION DETAILS IssueD. Ne 1999 VEFViTOON TYPE A~1 FILLET WELD ATTACHMENT DETAIL (t SKIRT-SHELL ATTACHMENT FOR TORISPHERICAL AND TORICONICAL HEADS ‘8 BLEND IN SMOOTHLY 10R — TAN. LINE SKIRT HEAD TYPE A-2 GROOVE WELD ATTACHMENT DETAIL (E=0.60) SEE NOTE 2 SKIRT—SHELL ATTACHMENT FOR TORISPHERICAL AND TORICONICAL HEADS NOTES: 7. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE 2. THIS DETAIL SHOULD BE USED FOR HIGH TEMPERATURE OR CYCLIC LOADING CONDITIONS. SKIRT ATTACHMENTS PROCESS INDUSTRY PRACTICES VEFV1 128M | D) FABRICATION/INSTALLATION. DETAILS —+ = + TN. LINE HEAD SKIRT | TYPE B-1 FILLET WELD ATTACHMENT DETAIL (E=0.60) SEE NOTE 1 SKIRT-SHELL ATTACHMENT FOR ELLIPSOIDAL OR HEMISPHERICAL HEADS BLEND _IN, SMOOTH — TAN. LINE 40" MIN HEAD 1.75¢ 1 375° wax TYPE B-2 GROOVE WELD ATTACHMENT DETAIL (E=0.70) SEE NOTES 1 & 2 SKIRT-SHELL ATTACHMENT FOR ELLIPSOIDAL OR HEMISPHERICAL HEADS NOTES: 1. TYPICALLY, THE SKIRT O.D, MATCHES THE VESSEL 0.0. IF THE SKIRT AND VESSEL SHELL THICKNESSES ARE SIMILAR. 2, THE TYPE B-2 ATTACHMENT SHOULD BE USED FOR HIGH TEMPERATURE OR CYCLIC LOADING CONDITIONS. 3. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE. PROCESS INDUSTRY PRACTICES VEFV1128M FABRICATION/INSTALLATION. DETAILS " se ia lan 7008 SKIRT ATTACHMENTS VEFVITOON SHELL: /— FULL PENETRATION BUTT WELD (TYP.) TAN. LINE ' FORGED CONNECTING PIECE | (WAY BE INTEGRAL WITH THE HEAD) 1 | BOTTOM HEAD sKiRT "| | TYPE C INTEGRAL SKIRT ATTACHMENT DETAIL (E = 1.0 WITH FULL RADIOGRAPHY) NOTE: THE TYPE C ATTACHMENT SHOULD BE USED FOR HIGH PRESSURE DESIGNS, VERY HIGH TEMPERATURES, AND LARGE VERTICAL LOADINGS IF THICK WALL SHELLS AND HEADS ARE REQUIRED. = PROCESS INDUSTRY PRACTICES VEFV1128M ») )) FABRICATION/INSTALLATION. DETAILS tsueb. we 1000 2 Z REAFFIRMED: JAN 7009 SKIRT ATTACHMENTS Pace 4 oF 5 VEFVITOON TOP RING LS. CONE TWO_GUSSETS STRADDLE EACH BOLT HOLE | BOLT HOLES ‘SPACED WEEP HOLES JPPORT RIN EQUALLY SPACED SUPPORT RING TYPE D CONE BOTTOM SOLIDS PRODUCT CONTAINER SKIRT DETAIL NOTE: TOP RING MAY BE USED TO REINFORCE CONE TO SHELL JUNCTION, = PROCESS INDUSTRY PRACTICES ») FABRICATION/INSTALLATION DETAILS e SKIRT ATTACHMENTS VEFV1128M ED: UNE 1099, FIRMED: JAN 2009 JACKET Ny \, TAN, LINE FORGED RING SKIRT TYPE E FILLET WELD ATTACHMENT DETAIL (E=0.60) SKIRT-SHELL ATTACHMENT FOR JACKETED VESSELS BOTTOM HEAD ELLIPTICAL OR HEMISPHERICAL PROCESS INDUSTRY PRACTICES VEFV1129M FABRICATION/INSTALLATION DETAILS houeb: sone“ VESSEL STUDDING JOINTS PAG OF 4 E (MIN) no 1 on. OF 0. READ x 4 CHAR eum sumo ea j a Z| nw r] 3 _ j i VN i on TAN I \ 7 2x 45° CHAMFER H (an) INSIDE. SURFACE: ‘STUD ENGAG. STUBS AND TAPPED JOWTS-STUDDED JONTS x a t 3 E F é ca we ez] 4 | 7 u > 0 | os | |" |p 3/4-10 UNC-2 7 19 13 44 2 16 2 s 2 7/e-9 we-2|_19 | 2 w« | «| » | 7 | os feos raw | 2 | 2 | 7 | = | 7 | ww | » |B32 vee] 2 | 2 | « | #2 | «= | 0 | » |Se8 tas wee] 36 a Ea 66 19 19 a |g *8 wyeawa[ 0 [2 fy [os [ss |» | «ls § zeu-2 | « | 2 os | | « | « | = ones: TS THE TOUATD ONENSIONS ARE ACCORDANCE WI ASME CODE SEC. VL OV 1. PAR XC—43g) REQUREMENTS FOR STUD MATERALS HAG FoR UATEOLS HUNG SHER ALOMIOLE STRESSES, DMENSINS SW, BE ADASTED ACCORONGLY “ 2: STUDS AND NUTS SLL BE POLYMID/AMDE COMED (252 © WAX. NAUEPLN, TEMPERATURES) 08 GALVANZED UNLESS SPECFCALY EXEMPTED BY He Ness SEDAN, SVOVERAL STA LENGTH WAY BE OEERMNED BY JOOWG THE THRESS OF THE WATNG FLANGE PLUS NUT HEGHT PLUS GASKET THIKNESS PLUS € lus THOIMESS OF SPICER (Fa) PLUS 6 AL" BNENGINS W MLNEIES, PROCESS INDUSTRY PRACTICES FABRICATION/INSTALLATION DETAILS | SOLIDS PRODUCT CONTAINER BLEND TUBE AND SHELL INTERFACE VEFV1130M ss 2009 a DEFLECTOR CONTOURED AROUND BLEND TUBE SECTION A-A DEFLECTOR DEFLECTOR |-—BLEND TUBE DEFLECTOR DETAILS Blend Tube/Cone Intersection PROCESS INDUSTRY PRACTICES FABRICATION/INSTALLATION DETAILS SOLIDS PRODUCT CONTAINER FLUSH-MOUNTED SIDE-ENTRY MANWAY DETAIL ISSUED: Jan 2008, REAFFIRWED: N/2 PAGE 1 OF vEFViTOOM HANDLE —, © sito SHELL REINFORCEMENT PLATE ON VI)

You might also like