You are on page 1of 2

FOR HILTI ANCHOR DESIGN, FOLLOWING DATA IS REQUIRED

For Anchor Design


Concrete Load (kN) Moment (kN-m)
Sr. Concrete Concrete Orientation Dimension Shear Shear
Tension(Axial) FoS
No. Grade (Column/Beam/Slab) (face is Z(along X(along Torsion Z Bending X Bending Y
underlined) Y
C2) C1)
CORE WALL 200mm THK
WALL & 16
1 60 105 36 58 0 18 1.5
DEFNITE
LENGTH
CORE WALL 200mm 1.5
2 60 200mm wide 0 0 240 0 0 0
WIDE

In addition to the above data pl. supply us with the following details of the base plate (if already decided):
L Application Diagram:
L: Length of the base plate= ---300------- mm----
Kindly provideB:the actual
Width of concrete dimension
the base plate= and hand
----600------ sketch.
mm------
C1 C1 & C2: spacing between the anchor= --150---- mm-----/------mm
B
Concrete dimension not----36-
Hole dia= available. Please
---------- provide minimum concrete depth required.
mm----
Existing bolt dia= ---------34------(to be checked for suitability)
(All dimensions in mm.)
C2
#Pl consider local axis for data inputs.
Name of the consultancy Firm:

Name of the Project:


Target Customer:
Name of the person responsible at site
Phone Number:

You might also like