You are on page 1of 5
DAFF DAFF CM HOOD CLEAN ROOMS TIEPA FILTER HOUSING FOR CEILINGS AND WALLS a WE 2a] S11 “ We mae Fitter Sab DAFF DCM HOOD FILTER APPLICATION The DCM Hoodis a ceiling module for HEPA filters such as the MICRO-DAFF OR LAMI-CELL. The module has been designed for use in applications where ultra clean air is required. Applications can be hospital operating theatres, intensive care units, biological laboratories and in production area for the pharmaceutical , food processing micro-electronic and optical industries. The DCM Hood qualifies for class 100 clean room environment when using the perforated plate on the downstream side accompanied by the proper filter selection. The units may also be applied in exhaust systems. CONSTRUCTION The standard DCM Hood is made of extruded aluminum and has a white (RAL9010) electrostatic powder coating which is resistant to disinfectants. The air enters through a round inlet collar on the side of the unit. As an option unit is available in Stainless Stee! and/or a round inlet collar on the top of the unit. Inside the unit the filter is secured against the filter frame by using spring loaded clamps. This provides a continuos and constant pressure against the filter sealing gasket. As an option test groove in the frame is available for testing the gasket seal, according to DIN 1946. A test tube is standard included on the unit for measuring the pressure drop over the filter. INSTALLATION The DCM Hood can be mounted in almost any type of ceiling. Predrilled holes for suspension wires are provided. As an option a module with an ‘outside flange is available. On the right are two installation examples. The filter itself is installed from the room side into the DCM Hood and is sealed by a spring-loaded clamp. Ifyou have a special installation requirement, our representative will be glad to provide you with a recommendation for your application. FUSERS There are three diffetent types of diffusers for air distribution a 4-way directional, a rectangle and a perforated plate. The diffusers are connected to a central holding are located inside the ceiling module. This holding bar is removable when installing or replacing the filter. For easy access to the filter and test ports measurement and/or DIN leak test) all three diffusers are removable from inside the room. the 4-way directional diffuser is standard electrostatic, polyester powder coated on off-white (RAL9002) ands mounted with a center bolt. The rectangle diffuser and perforated plate diffusers available in standard white (RAL9010).. Stainless steel diffusers is available as option. FILTERS The following filters can be used in the DCM Hood: Micro-DAFF or Lami-Cell with the efficiency of 99.99% on 0.3um or 99.999% on 0.12um particles. ~ DAFF DCM HOOD FILTER Exploded View & Construction 1 Heavy Duty Frame All Welded mild steel construction 2 Corrosion Resistant Mild Steel Frame is coated with a durable epoxy coating 3 Media Pack The MICRO-DAFF or LAMI-CELL element is supported by G.| Steel Painted plates at each corner 4 Replaceable Element The filter element can easily replaced requiring no special tools 5 Hanging Bracket Each housing is supplied with four corner hanging brackets to be used for scres, rods or hanging wires. 6 Collar Each housing is supplied with a 150mm or 200mm or 315mm standard round collar. 7 Optional Diffuser The powder coated diffuser is available as an optional extra Filter = sist DAFF TECHNICAL DATA AND DIMENSIONS FOR DCM HOOD WITH LAMI-CELL ULPA FILTRATION OF EFFICIENCY: > 99.9995% MODULE DIMENSION (in MM) FILTER Nominal airflow @0.45 m/s MOPELNO | Length x with cae (eeu *TaWxD- crM mh resistance (rm) | side inlet) | top inlet) | ™) Sena DMICD67-12122 300x300 360 200 290x290x57 88 150 200 DMICD67-12123 300x300 410 250 290x290x69 88 150 165 DMICD67-12124 300x300 460 300 290x290x90 88 150 135, DMicDe7-18182 | 450x450 360 200 | aa5xaa5xs7 | 200 340 195 DMICD67-18183 450x450 410 250 435x435x69 200 340 160 | OMICD67-18184 450x450, 460 300 435x435x90 200 340 130 DMicDe7-12242 | 600x600 360 200 | 200xaasxe7 | 176 300 195 | DMICD67-12243 300x600 410 250 290x590x69_ 176 300 160 | DMICD67-12244 300x600 460 300 290x590x90 176 300 130 |DMICD67-24242 600x600 360 200 590x590x57, 355 605 195, - |DMICD67-24243 600x600 410 250 590x590x69 355 605 160 |DMICD67-24244 600x600 460 300 590x590x90_ 355 605 130 DwicD67-24002| 600x750 480 200 | saoxzaoxs7 | 485 755 195 |DMICD67-24303 600x750 525 250 590x740x69 445 755 160 Dmicos7-24004| 600x750 570 300 | saoxraoxe0 | 445 755 130 [Dmico67-s0302| 750x750 480 200 | 7aoxraoxs7 | 555 940 195 Duico67-20303 | 750x750 525 250 | raoxraoxea | _555 940 160 [DicD67-30304| 750x750 570 300 | 740x740x00 | 955 940 130 | DMICD67-24372 600x900 480 200 590x890x57_ 535 905 195, Duicos7-2437| 600x900 525 250 | saoxea0xc9 | 595 905 160 | DMICD67-24374 600x900 570 300 590x890x90_ 535 905 130 Duicos7-24482| _600xr200 | 480 200 | seox1190x57 | 710 1205 195 [Duicoe7-24483 | _ 600x120 525 250 | seoxi190x60 | 710 1205 760 Duicoe7-24484| 600x120 | _ 570 300 | seox1190x00 | 710 1205 130 DESERT AIR FILTER FACTORY PO. BOX: 120 RIYADH 11383 K.S.A. : (ONOBR) 1 OBR ORRT Eay: (ONQER\ 1 ORE NDAT E-mail: allari@nnehny eam DAFF DMICD67 - DCM Hood Filter Housing Construction SS Circular top inlet 2 KR L oo w i 1 oe Rectangular side inlet d H| Ineraesed by spigt @ Circular side inlet

You might also like