You are on page 1of 44

ZTE SDR Solution for

MAKO Bermuda
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Author: Manager Responsible:


QU YIN

Doc No: Version: Controlled Copy No:


R0.6
Related Documents: Document Type:

Document Title: File Reference:


ZTE SDR Solution for MAKO Bermuda
Authorised by:

Version No. Date No. of Initials Details of Revision Changes


pages
R0.1 2017-02-16 46 Y

1.

1.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 3 of 44


ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

TABLE OF CONTENTS

TABLE OF CONTENTS ..................................................................................................................4

TABLES 6

FIGURES 7

1 SDR Hardware .............................................................................................................9


1.1 Product Introduction......................................................................................................9

1.1.1 BS8700 Architecture .....................................................................................................9

1.1.2 Radio Unit ................................................................................................................... 11

1.1.3 Baseband Unit ............................................................................................................ 19

2 BBU Engineering Plan ............................................................................................ 27


2.1 BBU slot plan.............................................................................................................. 27

2.1.1 Four BPN2 (4 COW Sites) ........................................................................................ 27

2.1.2 Three BPN2 (37 Sites) .............................................................................................. 27

2.1.3 Two BPN2 (6 Sites) ................................................................................................... 28

2.2 BBU&RRU Connection Plan ..................................................................................... 28

2.2.1 BBU&RRU Connection Scenario.............................................................................. 28

2.2.2 U850+L700+GL1900(6*R8882) ................................................................................ 29

2.2.3 U850+L700+G1900(3*R8882)+L1900(5*R8872A) ................................................. 29

2.2.4 U850(5*R8862A)+L700(5*R8862A)+G1900(3*R8882)+L1900(3*R8872A) ......... 30

2.2.5 U850(3*R8862A)+L700(3*R8862A)+L1900(3*R8872A) ........................................ 30

2.2.6 U850(3*R8862A)+L1900(3*R8872A) ....................................................................... 31

2.2.7 U850(2*R8862A)+L1900(2*R8872A) ....................................................................... 31

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 4 of 44


ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

3 SDR Power Connection.......................................................................................... 31

3.1 Power Connection Introduction............................................................................ 31

3.2 Power Connection of RRU to DCPD6 .................................................................. 32

3.2.1 DCPD6&RRU Connection Scenario......................................................................... 32

3.2.2 U850 3*R8862A +L700 3*R8862A+GL1900 6*R8882 ........................................... 33

3.2.3 U850 3*R8862A +L700 3*R8862A+G1900 3*R8882+L1900 5*R8872A .............. 34

3.2.4 U850 3*R8862A +L700 3*R8862A+L1900 3*R8872A............................................ 35

3.2.5 U850 3*R8862A +L1900 3*R8872A ......................................................................... 35

3.2.6 U850 5*R8862A +L700 5*R8862A+G1900 3*R8882+L1900 3*R8872A .............. 36

4 Transmission Solution ........................................................................................... 36

5 Clock Solution.......................................................................................................... 37

6 External Alarm Solution ......................................................................................... 37


6.1 External Alarm Solution ............................................................................................. 37
6.2 B201 Interfaces Connection...................................................................................... 38

7 Feeder Syste m Solution ......................................................................................... 39


7.1 Antenna Ports ............................................................................................................. 39
7.2 Feeder System Solution ............................................................................................ 41

7.2.1 ODI2-065R16M18J-GQ(Comba) (43 Sites)............................................................. 41

7.2.2 ODV-065R15E18K-G(Comba) (4 Sites) .................................................................. 42

7.2.3 5NPX1006F (3 COW Sites) ...................................................................................... 43

7.2.4 5UPX0805F (1 COW Sites) ...................................................................................... 43

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 5 of 44


ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

8 Data Design .............................................................................................................. 43

TABLES

Table 1-1 R8862A Modules ....................................................................................................... 12


Table 1-2 R8862A External Interfaces Description ................................................................. 13

Table 1-3 R8862A Performance ............................................................................................... 13

Table 1-4 R8882 Performance .................................................................................................. 14

Table 1-5 R8882 External Interfaces Description .................................................................... 15

Table 1-6 R8882 Performance .................................................................................................. 16

Table 1-7 R8882 Performance .................................................................................................. 16

Table 1-8 R8882 External Interfaces Description .................................................................... 18

Table 1-9 R8872A Performance ............................................................................................... 19


Table 1-10 Board List of ZXSDR B8200................................................................................... 20

Table 1-11 Key Indices of CCE1 Boards .................................................................................. 21

Table 1-12 CCE1 Panel Interfaces ........................................................................................... 21

Table 1-13 CCT Panel Interface & Functionality ..................................................................... 23

Table 1-14 FS5(FS5A) Panel Interfaces .................................................................................. 23

Table 1-15 Key Indices of BPN2 ............................................................................................... 24

Table 1-16 BPN2 Panel interfaces ............................................................................................ 24

Table 1-17 SA3 Panel Interfaces .............................................................................................. 25

Table 1-18 PM Panel Interfaces ................................................................................................ 26

Table 2-1 BBU&RRU Connection Scenario ............................................................................. 28

Table 3-1 DCPD6&RRU Connection Scenario ........................................................................ 32

Table 6-1 External Alarm Solution ............................................................................................... 37

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 6 of 44


ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

FIGURES

Figure 1-1 Example of ZXSDR BS8700 Physical Structure ................................................... 10

Figure 1-2 BS8700 Hardware Structure ................................................................................... 11

Figure 1-3 R8862A Physical Appearance ................................................................................ 11

Figure 1-4 External side Interfaces ........................................................................................... 12

Figure 1-5 R8882 (2*60W) Physical Appearance.................................................................... 14

Figure 1-6 R8882 External Interface......................................................................................... 15

Figure 1-7 R8872A (2*80W) Physical Appearance ................................................................. 17

Figure 1-8 R8872A External Interface ...................................................................................... 18

Figure 1-9 Baseband Unit -- ZXSDR B8200 ............................................................................ 20

Figure 1-10 CCE1 Panel ............................................................................................................ 21

Figure 1-11 FS5A Panel ............................................................................................................ 23


Figure 1-12 BPN2 Panel ............................................................................................................ 24

Figure 1-13 SA3 Panel............................................................................................................... 25

Figure 1-14 PM Panel ................................................................................................................ 26

Figure 2-1 Four BPN2 (4 COW Sites) ...................................................................................... 27

Figure 2-2 Three BPN2 (37 Sites) ............................................................................................ 27

Figure 2-3 Two BPN2 (6 Sites) ................................................................................................. 28

Figure 2-4 U850+L700+GL1900(6*R8882) .............................................................................. 29

Figure 2-5 U850+L700+G1900(3*R8882)+L1900(5*R8872A) ............................................... 29


Figure 2-6 U850(5*R8862A)+L700(5*R8862A)+G1900(3*R8882)+L1900(3*R8872A) ....... 30

Figure 2-7 U850(3*R8862A)+L700(3*R8862A)+L1900(3*R8872A) ...................................... 30

Figure 2-8 U850(3*R8862A)+L1900(3*R8872A) ..................................................................... 31

Figure 2-9 U850(2*R8862A)+L1900(2*R8872A) ..................................................................... 31


Figure 3-1 DCPD6 ...................................................................................................................... 32

Figure 3-2 U850 3*R8862A +L700 3*R8862A+GL1900 6*R8882 ......................................... 33

Figure 3-3 U850 3*R8862A +L700 3*R8862A+G1900 3*R8882+L1900 5*R8872A ............ 34

Figure 3-4 U850 3*R8862A +L700 3*R8862A+L1900 3*R8872A .......................................... 35

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 7 of 44


ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 3-5 U850 3*R8862A +L1900 3*R8872A ....................................................................... 35

Figure 3-6 U850 5*R8862A +L700 5*R8862A+G1900 3*R8882+L1900 3*R8872A ............ 36

Figure 4-1 IP Connection ........................................................................................................... 36

Figure 5-1 GPS Connection ...................................................................................................... 37

Figure 6-1 B201 Interfaces Connection....................................................................................... 38

Figure 7-1 ODI2-065R16M18J-GQ(Comba) Ports .................................................................. 39

Figure 7-2 ODV-065R15E18K-G(Comba) Ports...................................................................... 40

Figure 7-3 Tower Top R8862A S8500 + R8882 ...................................................................... 41

Figure 7-4 Tower Top R8862A S8500 + R8872A.................................................................... 41

Figure 7-5 Ground R8862A S8500 ........................................................................................... 42

Figure 7-6 Tower Top RRU ....................................................................................................... 42

Figure 7-7 5NPX1006F (3 COW Sites) .................................................................................... 43

Figure 7-8 5UPX0805F (1 COW Sites) .................................................................................... 43

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 8 of 44


ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

1 SDR Hardware

1.1 Product Introduction

This section is for Detailed Description of RRU and BBU.

1.1.1 BS8700 Architecture

ZXSDR BS8700 consists of the BBU (B8200) and RRUs. The physical
structures of ZXSDR BS8700 are shown as follow:

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 9 of 44


ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-1 Example of ZXSDR BS8700 Physical Structure

BS8700 hardware architecture is shown as follow:

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 10 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-2 BS8700 Hardware Structure

The BBU of ZXSDR BS8700 can be configured in GSM/UMTS/LTE single mode


or multi-mode.

1.1.2 Radio Unit

1.1.2.1 Radio Unit ZXSDR R8862A

R8862A is the latest SDR based remote RF unit (RRU), featuring 2-way
transmitting and 4-way receiving. The physical appearance is shown below.
Figure 1-3 R8862A Physical Appearance

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 11 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

R8862A consists of quad-channel transceiver (QTR), duplex filters LNA (DFL),


power amplifier (PA), power module (PWR) and protecting interface board (PIB).
Functions of each module are shown below.
Table 1-1 R8862A Modules
Module Main Function

QTR Receives and transmits the signals of panel interfaces, digital intermediate
frequency and RF, and provides controls clock, power and power amplification
functions.

DFL Combine and isolate transmitted and received signal, filter the transmitted
signal and received signal, provide DFL alarm monitor function.

PA Perform radio signal amplifying and Low-Noise-Amplifier (LNA) function,


generate temperature report, and perform power protection function.

PWR Provides power supply function and monitors power state.

PIB Integrated lightning protect unit for the AISG, RS485 and dry contacts, and the
protection level is 20 KA.

External interfaces of R8862A are located at the bottom and side of the module,
as shown below.
Figure 1-4 External side Interfaces

The interface descriptions are listed as follows.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 12 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Table 1-2 R8862A External Interfaces Description


S.N. Label Interface Interface Type/Connector

BBU and RRU Interfaces /


1 OPT1 LC-mode optical interface (IEC 874)
RRU cascading interface

2 OPT2 RRU cascading interface LC-mode optical interface (IEC 874)

PWR Power input interface 2-pin customized connector


3 Grounding cable interface
-
for AC power supply

Protection
4 GND 16 mm2 yellow/green round terminal
ground interface

AISG equipment interface


External monitoring
5 AISG/MON DB15 connector
interface &
LMT O&M Ethernet interface

TX/RX
ANT1
6 antenna 50Ω DIN-mode Connector
(TX/RX)
feeder interface

7 ANT2 (RX) RX antenna interface 50 Ω DIN-mode connector

8 ANT3 (RX) RX antenna interface 50 Ω DIN-mode connector

ANT4
9 TX/RX antenna interface 50 Ω DIN-mode connector
(TX/RX)
Table 1-3 R8862A Performance
R8862A Performance Index

instantaneous bandwidth 45MHz

Receiver Sensitivity - 106dBm @ Single Antenna

TOC 2*60W

1.1.2.2 Radio Unit ZXSDR R8882

R8882 is the multi-carrier RF module with two transmitters. Now ZTE provides
R8882 series, R8882 2*60W, 2T4R.In the physical appearance, R8882 2T4R
has four antenna feeder interfaces.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 13 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Table 1-4 R8882 Performance

Channel R8882 Module (1900MHz)

2T4R S1900

The physical appearance is shown as follows.


Figure 1-5 R8882 (2*60W) Physical Appearance

R8882’s external interfaces locate in the bottom and side of the cabinet, as
shown below. The interface description is listed in the following table.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 14 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-6 R8882 External Interface

Table 1-5 R8882 External Interfaces Description


S.N. Label Interface Interface Type/Connector

-48V DC power input


1 PWR 2-pin round plastic connector (male)
interface

External monitoring
2 MON 8-pin circle connector (male)
interface

8-pin circle connector (IEC 60130-9-ED)


3 AISG AISG interface
(female)
4 GND PE interface 16 mm2 yellow-green round terminal

BBU and RRU


5 OPT1 Interface/RRU cascading LC-mode optical interface (IEC 874)
interface

6 OPT2 RRU cascading interface LC-mode optical interface (IEC 874)

ANT1 Antenna feeder interface


7 50 Ω DIN-mode connector
(TX0/RX0) (Tx0/Rx0)

ANT2
Antenna feeder interface
8 (RX2) 50 Ω DIN-mode connector
(Rx2)
(Optional*)

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 15 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

ANT3
Antenna feeder interface
9 (RX3) 50 Ω DIN-mode connector
(Rx3)
(Optional*)
Antenna feeder
ANT4
10 interface 50 Ω DIN-mode connector
(TX1/RX1)
(Tx1/Rx1)
Ethernet interface
11 LMT for operation and RJ45
maintenance

Optional*: NO ANT2 and ANT3 in 2T2R products.


Table 1-6 R8882 Performance
R8882 Performance Index

instantaneous bandwidth 40MHz


Receiver Sensitivity -105.5dBm @ Single Antenna

TOC 2*60W

1.1.2.3 Radio Unit ZXSDR R8872A

R8872A is the multi-carrier RF module with two transmitters. Now ZTE provides
R8872A series, R8872A 2*80W, 2T4R.In the physical appearance, R8872A
2T4R has four antenna feeder interfaces.
Table 1-7 R8882 Performance

Channel R8872A Module (1900MHz)

2T4R S1900

The physical appearance is shown as follows.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 16 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-7 R8872A (2*80W) Physical Appearance

R8872A’s external interfaces locate in the bottom and side of the cabinet, as
shown below. The interface description is listed in the following table.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 17 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-8 R8872A External Interface

Table 1-8 R8882 External Interfaces Description


S.N. Label Interface Interface Type/Connector

-48V DC power input


1 PWR 2-pin round plastic connector (male)
interface

External monitoring
2 MON 8-pin circle connector (male)
interface
8-pin circle connector (IEC 60130-9-ED)
3 AISG AISG interface
(female)
4 GND PE interface 16 mm2 yellow-green round terminal

BBU and RRU


5 OPT1 Interface/RRU cascading LC-mode optical interface (IEC 874)
interface

6 OPT2 RRU cascading interface LC-mode optical interface (IEC 874)

ANT1 Antenna feeder interface


7 50 Ω DIN-mode connector
(TX/RX) (Tx/Rx)

ANT2 Antenna feeder interface


8 50 Ω DIN-mode connector
(RX) (Rx)

ANT3 Antenna feeder interface


9 50 Ω DIN-mode connector
(RX) (Rx)

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 18 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Antenna feeder
ANT4
10 interface 50 Ω DIN-mode connector
(TX/RX)
(Tx/Rx)
Ethernet interface
11 LMT for operation and RJ45
maintenance
Table 1-9 R8872A Performance
R8872A Performance Index

instantaneous bandwidth 60MHz


Receiver Sensitivity -105.5dBm @ Single Antenna

TOC 2*80W

1.1.3 Baseband Unit

1.1.3.1 ZXSDR B8200

The base-band processing Unit (BBU) ZXSDR B8200 (hereinafter B8200) can
be inserted into the integrated macro base station, or connected to RRU in
distributed base station. It is responsible for processing the base-band signals.
Based on ZTE SDR platform, it supports GSM, UMTS and LTE single-mode or
multi-mode by software configuration. It enables operators to deploy one unified
radio access network rather than independent GSM, UMTS or LTE network,
which brings simplicity and convenience with low CAPEX and OPEX.The
following figure shows the hardware appearance of B8200.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 19 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-9 Baseband Unit -- ZXSDR B8200

The baseband unit consists of control & clock board, fabric switch board,
baseband processing board, site alarm board, site alarm extension board
(optional), universal Ethernet switch (optional), tower mounted amplifier control
module (optional), power module, and fan module.
Table 1-10 Board List of ZXSDR B8200
Board Name Function Description

CC16B/CC16 Control & Clock Board


FS5 Fabric Switch Board

FS5A Fabric Switch Board


BPK Baseband Processing board for UMTS
BPN2 Baseband Processing board for GUL multi-mode

BPK_D Baseband Processing board for UMTS

SA Site Alarm Board

PM3 Power Module


FAM Fan Array Module

1.1.3.2 CCE1 Board

CCE1 is the control & clock board, used for control and management of
baseband unit, providing Ethernet and system clock.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 20 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-10 CCE1 Panel

The key indices are specified in the following table:


Table 1-11 Key Indices of CCE1 Boards
CC Type CCE1

Mode G/U/L single mode or multi-mode

36 2T2R Cells
LTE Processing Capability 10800 RRC_ connected users
UL: 1.8Gbps/ DL: 3.6Gbps

Note: The above table describes the maximum hardware capability. The actual
capability is up to the licenses configured. There is the GPS module embedded in
CCE1.

The panel interfaces are specified in the following table.


Table 1-12 CCE1 Panel Interfaces
Interface Name Description

External communication port, connected to external receiver for clock


EXT
synchronization or cascading.
REF Connected to GPS signal interface, or 2 MHz BITS signal interface.

USB Used for software upgrade

Ethernet interface for Abis/Iub/S1/X2, self-adaptive 100M/1000M


TX RX
optical interface.

Ethernet interface for Abis/Iub/S1/X2, self-adaptive 10M/100M/1000M


ETH0
electrical interface.
Ethernet interface used for cascading, debugging or local
DEBUG/CAS/LMT
maintenance, adapting interface of 10M/100M/1000M.

Note: Interfaces of ETH0 and TX RX are mutually exclusive.

Their main functions are listed as follows:

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 21 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

 Accomplishes LTE control plane protocol processing, including S1AP, X2AP,


RRC, etc

 Supports Ethernet switching function and implements data switching for service
and control flow within the system

 Processes Abis/Iub/S1/X2 interface protocol

 Manages software versions of boards and programmable components, and


supports local and remote software upgrade

 Reads various hardware management marks in the system, including the rack
number, backplane type number, slot number, board function type, board
version, and board function configuration mark

 Monitors, controls and maintains the base station system with LMT interface

 Supervises the running status of each board within the system

 Supports primary/slave switchover

 Synchronizes with various external reference clocks, including IEEE1588, GPS


clock and the clock provided by BITS (2MHz, 2Mbits). The CC can select one
according to the actual configuration

 Generates and delivers the clock signal demanded by each part

 Provides GPS receiver interface and manages the GPS receiver

 Provides a real-time clock for system operation and maintenance and calibrates
the real-time clock

 Supports Micro TCA protocol based module management function

 Supporting Synchronous Ethernet clock

 Providing USB interface for software upgrade

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 22 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

In order to process the high system load caused by the signaling storm or other
situations, one BBU is suggested to be configured with 2 CC boards for different
modes: one for GU dual-mode and the other for LTE mode

1.1.3.3 FS5A Board

FS is fabric switch board which provides the optical interface between BBU and
RRU and processes the IQ signal. FS5 board, illustrated in the following figure:
Figure 1-11 FS5A Panel

Their key indices are specified in the following table.


Table 1-13 CCT Panel Interface & Functionality
FS Type FS5

Mode G/U/L single mode or multi-mode

CPRI Interface Data Rate (Gbps) 1.2288/2.4576/3.072/6.144

The panel interfaces are specified in the following table.


Table 1-14 FS5(FS5A) Panel Interfaces
Interface Name Description

TX0 RX0 to TX5 RX5 6 pairs of optical/electrical interfaces, connected to RRU/RSU

Note: Optical interfaces are configured by default.

Their main functions are listed as follows:

 Receives the signal from the rear board in the downlink and retrieves the data and
timing.

 Multiplexes the received data and retrieves I/Q signal

 Supports I/Q mapping in the downlink and multiplexes I/Q signal to the optic al
signals

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 23 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

 Receives the I/Q in uplink and de-multiplexes/maps into I/Q signal

 Transmits the multiplexed I/Q signal to baseband processing board

 Exchanges the CPU interface signaling through HDLC interface with RU module

1.1.3.4 BPN2 Board

BPN2 is the GSM/UMTS/LTE multi-mode baseband processing boards,


integrating all the functions provided by the G/U/L single mode BP boards. It can
be configured as G/U/L single mode or multi-mode, illustrated in the following
figure.
Figure 1-12 BPN2 Panel

Note: The boards are differentiated by the label attached at the left -bottom corner, not
included in the above figures. The product you receive is subject to the actual object.

The key indices are specified in the following table.


Table 1-15 Key Indices of BPN2
Board BPN2

CPRI Interfaces 6 pairs

12 2T2R Cells
LTE 7200 RRC_ connected Users
DL 1200Mbps/UL 600Mbps

Note: The above table describes the maximum hardware capability. The actual capability
is up to the licenses configured.

The panel interfaces are specified in the following table.


Table 1-16 BPN2 Panel interfaces
Board Type Interface Description

BPN2 TX0 RX0 ~ TX5 RX5 6 pairs of CPRI optical/electrical interfaces,

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 24 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Board Type Interface Description


connected to RRU/RSU

1.1.3.5 SA3 Board

SA is a site alarm board, illustrated in the following figure.


Figure 1-13 SA3 Panel

Table 1-17 SA3 Panel Interfaces


Interface Name SA0
- 4 E1/T1 interfaces

16 dry contacts (6 input, 2 bidirectional)

1 RS485 interface
1 RS232 interface

The SA3 has the following functions:

 Provides E1/T1 transmission interfaces

 Provides site alarm monitoring interfaces

 Provides FAM's alarm and rate control

 Supports signal monitoring and interface lightning protection


 The last E1 used for E1 transmission or BITS-2MHz/BITS-2Mbps clock input

1.1.3.6 PM Board

PM is the power module, illustrated in the following figure.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 25 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 1-14 PM Panel

Note: The product you receive is subject to the actual object.

The panel interfaces are specified in the following table.


Table 1-18 PM Panel Interfaces
Interface Name Description

MON Debugging interface, RS232 interface

-48V/-48VRTN -48V input


ON/OFF Power switch, turning on/off 12V power to/from BBU

The PM has the following functions:

 Provides 16 internal interfaces for +12 V, +13V or +28V load power

 Provides 16 internal interfaces for +3.3 V management power

 Supports EMMC management

 Supports measurement and protection of input over-voltage/under-voltage

 Supports output over-current protection and load power management

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 26 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

2 BBU Engineering Plan

2.1 BBU slot plan

2.1.1 Four BPN2 (4 COW Sites)


Figure 2-1 Four BPN2 (4 COW Sites)

2.1.2 Three BPN2 (37 Sites)


Figure 2-2 Three BPN2 (37 Sites)

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 27 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

2.1.3 Two BPN2 (6 Sites)


Figure 2-3 Two BPN2 (6 Sites)

2.2 BBU&RRU Connection Plan

2.2.1 BBU&RRU Connection Scenario


Table 2-1 BBU&RRU Connection Scenario
Site
Scenario RRU Type
Number
1 U850+L700+GL1900(6*R8882) 32
2 U850+L700+G1900(3*R8882)+L1900(5*R8872A) 3
3 U850(5*R8862A)+L700(5*R8862A)+G1900(3*R8882)+L1900(3*R8872A) 1
4 U850(3*R8862A)+L700(3*R8862A)+L1900(3*R8872A) 5
5 U850(3*R8862A)+L1900(3*R8872A) 5
6 U850(2*R8862A)+L1900(2*R8872A) 1
Total 47

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 28 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

2.2.2 U850+L700+GL1900(6*R8882)
Figure 2-4 U850+L700+GL1900(6*R8882)

2.2.3 U850+L700+G1900(3*R8882)+L1900(5*R8872A)
Figure 2-5 U850+L700+G1900(3*R8882)+L1900(5*R8872A)

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 29 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

2.2.4 U850(5*R8862A)+L700(5*R8862A)+G1900(3*R8882)+L1900(3*R8872A)
Figure 2-6 U850(5*R8862A)+L700(5*R8862A)+G1900(3*R8882)+L1900(3*R8872A)

2.2.5 U850(3*R8862A)+L700(3*R8862A)+L1900(3*R8872A)
Figure 2-7 U850(3*R8862A)+L700(3*R8862A)+L1900(3*R8872A)

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 30 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

2.2.6 U850(3*R8862A)+L1900(3*R8872A)
Figure 2-8 U850(3*R8862A)+L1900(3*R8872A)

2.2.7 U850(2*R8862A)+L1900(2*R8872A)
Figure 2-9 U850(2*R8862A)+L1900(2*R8872A)

3 SDR Power Connection

3.1 Power Connection Introduction

ZTE provide DCPD6 for all site configuration, include all scenarios.

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 31 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 3-1 DCPD6

DCPD6

987654321

3.2 Power Connection of RRU to DCPD6

3.2.1 DCPD6&RRU Connection Scenario


Table 3-1 DCPD6&RRU Connection Scenario
Site
Scenario RRU Type
Number
1 U850 3*R8862A +L700 3*R8862A+GL1900 6*R8882 32
2 U850 3*R8862A +L700 3*R8862A+G1900 3*R8882+L1900 5*R8872A 3
3 U850 3*R8862A +L700 3*R8862A+L1900 3*R8872A 5
4 U850 3*R8862A +L1900 3*R8872A 6
5 U850 5*R8862A +L700 5*R8862A+G1900 3*R8882+L1900 3*R8872A 1
Total 47

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 32 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

3.2.2 U850 3*R8862A +L700 3*R8862A+GL1900 6*R8882


Figure 3-2 U850 3*R8862A +L700 3*R8862A+GL1900 6*R8882

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 33 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

3.2.3 U850 3*R8862A +L700 3*R8862A+G1900 3*R8882+L1900 5*R8872A


Figure 3-3 U850 3*R8862A +L700 3*R8862A+G1900 3*R8882+L1900 5*R8872A

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 34 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

3.2.4 U850 3*R8862A +L700 3*R8862A+L1900 3*R8872A


Figure 3-4 U850 3*R8862A +L700 3*R8862A+L1900 3*R8872A

3.2.5 U850 3*R8862A +L1900 3*R8872A


Figure 3-5 U850 3*R8862A +L1900 3*R8872A

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 35 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

3.2.6 U850 5*R8862A +L700 5*R8862A+G1900 3*R8882+L1900 3*R8872A


Figure 3-6 U850 5*R8862A +L700 5*R8862A+G1900 3*R8882+L1900 3*R8872A

4 Transmission Solution
All IP transmission for every sites.

Figure 4-1 IP Connection

Switch

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 36 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

5 Clock Solution
Every sites configured with GPS.

Figure 5-1 GPS Connection

GPS

6 External Alarm Solution

6.1 External Alarm Solution

Table 6-1 External Alarm Solution


BBU External B201 Alarm code
Pair. B201 Power alarm
Alarm Cable Color in CSU
White
0 X15-1 CSU faulty_1
Green
White
1 X15-2 Main fail_1 A2
Brown
White
2 X16-1 Low battery_1 A3
Gray
Red
Cable 1 3 X16-2 Door cabinet_1 A4
Blue
Red
4 X17-1 Rect fail_1 A5
Orange
Red
5 X17-2 High Temp_1 A6
Green
White
10 TNB
Blue

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 37 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

White
11
Orange
Write
6
Blue
Write
7
Orange
White
8
Green
White
9
Brown
Cable 2
Write
12
Gray
Red
13
Blue
Red
14
Orange
Red
15
Green

6.2 B201 Interfaces Connection


Figure 6-1 B201 Interfaces Connection

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 38 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

7 Feeder System Solution

7.1 Antenna Ports


Figure 7-1 ODI2-065R16M18J-GQ(Comba) Ports

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 39 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 7-2 ODV-065R15E18K-G(Comba) Ports

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 40 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

7.2 Feeder System Solution

7.2.1 ODI2-065R16M18J-GQ(Comba) (43 Sites)


Figure 7-3 Tower Top R8862A S8500 + R8882

ODI2-065R16M18J-GQ(Comba)
R1 R2 Y1 Y2
698-787MHz 824-894MHz 1695-2360MHz 1695-2360MHz
+45 -45 +45 -45 +45 -45 +45 -45
AISG

ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4

R8862A R8862A R8882 R8882


S7000 S8500 S1900 S1900

AISG

Figure 7-4 Tower Top R8862A S8500 + R8872A

R1 R2 Y1 Y2
698-787MHz 824-894MHz 1695-2360MHz 1695-2360MHz
+45 -45 +45 -45 +45 -45 +45 -45
AISG

ANT1 ANT4 ANT1 ANT4 ANT1 ANT4

R8862A R8862A R8872A


S7000 S8500 S1900

AISG

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 41 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

Figure 7-5 Ground R8862A S8500

ODI2-065R16M18J-GQ(Comba)
R1 R2 Y1 Y2
698-787MHz 824-894MHz 1695-2360MHz 1695-2360MHz
+45 -45 +45 -45 +45 -45 +45 -45
AISG

ASBT

NSBT

ANT1 ANT4

R8862A
S8500
AISG

7.2.2 ODV-065R15E18K-G(Comba) (4 Sites)


Figure 7-6 Tower Top RRU

ODV-065R15E18K-G(Comba)
R1 Y1
694-960MHz 1695-2690MHz
+45 -45 +45 -45
AISG AISG

ANT1 ANT4 ANT1 ANT4

R8862A R8872A
S8500 S1900

AISG AISG

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 42 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

7.2.3 5NPX1006F (3 COW Sites)


Figure 7-7 5NPX1006F (3 COW Sites)

5NPX1006F

ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4

R8872A R8872A R8872A R8872A R8872A


S1900 S1900 S1900 S1900 S1900

7.2.4 5UPX0805F (1 COW Sites)


Figure 7-8 5UPX0805F (1 COW Sites)

5UPX0805F 5UPX0805F

ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4 ANT1 ANT4

R8862A R8862A R8862A R8862A R8862A R8862A R8862A R8862A R8862A R8862A
S8500 S8500 S8500 S8500 S8500 S7000 S7000 S7000 S7000 S7000

8 Data Design
 TOC of 1900MHz: 2*40W/carrier(LTE)

 TOC of 1900MHz:20W/TRX(GSM)

 TOC of 850MHz: 40W/CS(UMTS)

 TOC of 700MHz(B13): 2*40W/carrier(LTE)

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 43 of


44
ZTE SDR Solution for MAKO Doc No. :
Bermuda Revision No : R1.0 Issued : 20170216

Dept/Team: Template No. :


Prepared by :

 1024 CE per S222 UMTS

Distribution – ZTE, UMoblie Confidential to ZTE and U Mobile Page 44 of