You are on page 1of 9

IOP Conference Series: Materials Science and Engineering

PAPER • OPEN ACCESS Related content


- Some Remarks on Foundation Pile
Interesting Developments in Testing Methods Testing Procedures
Jarosaw Rybak
Applied to Foundation Piles - Hand-held digital sonic pile-testing system
G G Coghill and H W Whittington
To cite this article: Dariusz Sobala and Grzegorz Tkaczyski 2017 IOP Conf. Ser.: Mater. Sci. Eng. 245 - Analysis on pile testing results of post-
022074 grouting bored pile
A R Zheng

View the article online for updates and enhancements.


Recent citations
- Limitations and risk related to static
capacity testing of piles – “unfortunate
case” studies
Jarosaw Rybak et al

This content was downloaded from IP address 111.95.205.70 on 12/02/2018 at 22:53


WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

Interesting Developments in Testing Methods Applied to


Foundation Piles

Dariusz Sobala1, Grzegorz Tkaczyński2


1
Rzeszow University of Technology, Faculty of Civil and Environmental Engineering
and Architecture, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland
2
METRIS Sp. z o.o. Instytut Badań dla Budownictwa.
ul. Łąkoszyńska 127A, 99-300 Kutno, Poland

d.sobala@prz.edu.pl

Abstract. Both: piling technologies and pile testing methods are a subject of current
development. New technologies, providing larger diameters or using in-situ materials, are very
demanding in terms of providing proper quality of execution of works. That concerns the
material quality and continuity which define the integral strength of pile. On the other side we
have the capacity of the ground around the pile and its ability to carry the loads transferred by
shaft and pile base. Inhomogeneous nature of soils and a relatively small amount of tested piles
imposes very good understanding of small amount of results. In some special cases the
capacity test itself form an important cost in the piling contract. This work presents a brief
description of selected testing methods and authors remarks based on cooperation with
Universities constantly developing new ideas. Paper presents some experience based remarks
on integrity testing by means of low energy impact (low strain) and introduces selected
(Polish) developments in the field of closed–end pipe piles testing based on bi-directional
loading, similar to Osterberg idea, but without sacrificial hydraulic jack. Such test is suitable
especially when steel piles are used for temporary support in the rivers, where constructing of
conventional testing appliance with anchor piles or kentledge meets technical problems.
According to the author’s experience, such tests were not yet used on the building site but they
bring a real potential especially, when the displacement control can be provided from the river
bank using surveying techniques.

1. Introduction – testing the quality of foundation piles and other inspection procedures
The quality testing refers mainly to verifying continuity and length of piles using low stress methods
like: Pile Integrity Test (PIT), Sonic Integrity Test (SIT) or Pile Echo Test (PET); not so often the
scanning with Cross-hole Sonic Logging (CSL) method or pile survey under the structure is used.
A common practice is usually reduced to law strain test which can be performed if only the access to
pile head is granted [1]. When there is no access to pile head, other techniques, requiring parallel
drilling must be considered.
Another group of tests developing dynamically – especially due to the Eurocodes knocking at the
door – are the techniques which enable to analyse the distribution of bearing capacity of the grounds
around (along the pile shaft) and in the base of pile, such as application of Osterberg cell [2] or
equipping the piles with strain gauges secured to pile reinforcement. Other bidirectional tests were
developed in 1988 by Slovak engineers [3] for bored piles and by Hayden [4] for slender piles. These

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution
of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
Published under licence by IOP Publishing Ltd 1
WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

operations are pioneering nature in Poland, they were not so far widely described nor tested but their
value cannot be stressed enough [4]. Recently, new ideas were presented by Baca et al. [6] who
developed original idea of Hayden by means of bi-directional steel testing appliance which enables for
controlling the capacity of closed-end steel piles [7].

2. Methods of control tests for pile integrity and length


Dynamic development of piling technologies having been observed now brings essential challenges to
participants of construction process referring to quality assurance: current inspection of works and also
acceptance tests for piles and columns made with new technologies frequently not specified in
standards. It especially refers to control of length and continuity of these components. It should be
noted that reinforced concrete piles and soil-cement columns belong to rare elements of structures
which inspection is very straitened, as (except the head) there is no access in practice. Polish Standard
PN-83/B-02482 poses no requirements for inspecting piles and columns made in soil using such technologies
as CFA (continuous flight auger), driven piles (FDP – full displacement pile, SDC – soil displacement
column), Omega piles, columns formed with immersion vibrator, DSM (deep soil mixing) and jet-grouting
(soilcrete). The related risk is higher than that in traditional technologies (bored piles in shielding pipes or
prefabricated piles).
The factors of uncertainty are here as follows:
 limited control over formation process,
 limited control of pile or column material,
 frequently there is no reinforcement,
 sensitivity to “human factor” – awareness of threats from contractors.
In general, the quality control of pile and column execution is ensured by acoustic methods, introduced to
engineering practice, for testing their length and continuity. Appropriate instrumentation is at disposal of
some academic centres and contracting companies. The idea of these examinations is based on analysing the
elastic wave in the pile (caused by hammer hit) [1], [9].
A separate and much more complex problem is the inspection or survey of foundation piles which are
located under existing structure when pile heads are inaccessible. Such cases are quite often lately in highway
and railway structures: alterations of bridges and overpasses to higher class of loads, when foundation survey
is necessary to ensure proper design of reinforcement.
A number of method based on application of seismic sensors, arranged in series or moved along a hole
parallel to the pile being surveyed, have been developed in recent years. It shall be stressed that such methods
can be also used to survey earth-sheltered massive structures and retaining walls, sheet pilings, diaphragm
walls and palisades. Below, there is a review of destructive testing of piles used to verify their quality of the
workmanship – examining their length and continuity. Also the basis of measurements and rules for result
analysis are presented.

2.1. PIT and SIT methods


In testing methods SIT (sonic integrity test) and PIT (pile integrity test) the measurement is initiated by
inducing an elastic wave using appropriated calibrated hammer with end made out of hardened resin.
Measurement kits for SIT and PIT methods are shown in Fig. 1 and Fig.2, respectively. The continuity test is
based on wave propagation velocity and wave reflection in continuous media. The wave, while meeting the
pile end, its contraction or fracture, reflects and returns to the head surface. This is recorded by the receiver.
Then, using computer software, the testing results are prepared. When wave return time t is known, the pile
length Lp can be calculated from the formula (1):
t
L p  Vb (1)
2
where: Vb is the wave velocity in pile concrete.

2
WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

To keep the result reliable, it is recommended that the pile slenderness (i.e. its length to diameter ratio) would
not exceed 30. However, measurements were also taken for piles in weak soils where slenderness was 60.

Figure 1. Pile Integrity Test (PIT equipment of METRIS) for examining pile length and continuity
a) driven pile, b) CFA pile
Technical University in Wroclaw 09-01-14 Technical University in Wroclaw 09-01-14
MOST; Pile: PROBNY 1OK4 Collected: 08-10-31 MOST; Pile: niedobity Collected: 08-10-31
PROBNY 1OK4 Profile 2003-2 niedobity Profile 2003-2
PROBNY 1OK4
5: # 20+19% 6: # 3 niedobity
ACC-E, HAM-C, WT 26.7 N
-0.01 0.00 0.01 0.02 cm/s -0.20 0.00 0.20 0.40 cm/s
ACC-N, HAM-C, WT 26.7 N

Wavelet 3.48 m 575 Hz


Pivot 19 %

0 0 0 0

1 1

2 2
5 5
3 3

4 4
10 10
5 5
Relative Vol.: 0.89 Relative Vol.: 1.41
6 Construct. Vol.: 1.00 Construct. Vol.: 1.00
6
Construct. Area: 1.00 Construct. Area: 1.00
15
7 Max Profile: 1.21 at 6.48 m 15 Max Profile: 1.38 at 7.32 m
7
Min Profile: 0.26 at 9.00 m Min Profile: 0.33 at 3.32 m
8
8
9.00 m (4000 m/s)
9 20 9.00 m (4000 m/s)
x 15 9 20
10
10
11
25 11
25
12
12
Magn V 0.013 cm/s (0.019) m diam V 0.347 cm/s (0.347) m diam

Figure 2. Results of examinations (Technical University in Wroclaw) with PIT method for:
a) continuous pile 9.0 m long, b) pile with fracture at distance of 3.5 m from pile head

There are numerous papers about experiences with such low strain testing. In general, authors pay a
major attention to testing methodology for various piling technologies [10]. Above, there are
exemplary results of examinations with PIT method, made by Technical University in Wroclaw for
driven piles made by AARSLEFF. Figure 2a gives the result of analyses made for continuous pile 9.0
m long. There are no doubts about its length and continuity. The analysis given below is of qualitative
nature; however, it “quite precisely” shows the interpreted length of pile. In case of pile which
examination is shown in Fig. 2b, an essential change in its cross-section at the depth of about 3.5 m
can be suspected. This is confirmed in frequency diagram where the pile length was estimated at 3.2 to
3.7 m. The pile which examination is presented in Fig. 2b was not driven to the full depth because the
operator of pile driver notices a sudden change of driving resistance. Following the pile was unearthed
to 3.40 m below pile head, a transverse fracture was revealed.
In case of prefabricated piles, pile contraction is not possible, and pile length can be determined
prior it is driven. Hence, this testing is used to determine whether given pile was not broken during
driving it and whether the contractor did not use shorter piles than those given in documentation. The

3
WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

issues of testing calibration for prefabrication piles examined with PIT method in terms of proper
determination of wave velocity in pile was described in [12]. Experience proved that wave
propagation velocity in prefabricated piles (C40/50 concrete) is about 4.150 m/s. The velocity in bored
piles (C20/25 concrete), and especially in CFA piles (C20/25 sand concrete with liquid consistence) is
lower and amounts to less than 4.000 m/s. Lower velocity of wave propagation is related to lower
integrity and lower class of concrete [13].
The time elapsed from completing the pile to its examination is an additional factor which needs to
be taken into account. It is because the velocity of elastic wave propagation is dependent on
incremental strength of the pile. That issue was recently widely described by numerous authors
[14][15]. In general, it is recommended not to make examinations earlier than 7 days after pile
completion (pouring the concrete). According to author’s experience from large number of tests
performed by METRIS company, testing piles prior the pile medium reaches its full strength (when
wave velocity is less than assumed one) is possible, however can lead to funny mistakes when, at
wave velocity about 3600 m/s, the pile length is found to be even 10% longer than that declared by
pile work contractor. A series of testing made after 5-12 days after completing the concrete columns
indicated that wave velocities in C20/25 concrete were from 3250 to 3600 m/s approximately. Those
values are in general in accordance with recommendations given by Rybak [16]. Extremely difficult
for interpreting is testing of soil-cement columns made with injection technologies or with deep soil
mixing method (DSM). The column material is here so heterogeneous (see Figure 3) that we cannot
use implemented mathematical model of the pile. Quality testing is of special importance in case of
technologies susceptible for unpredictable conditions in the subbase and “human factor”. Finally, even in the
case of concrete piles, we should not expect an accuracy exceeding 5-10%. The variability of PEM test
results (Pile Echo Method) was also described by Amir [17].

2.2. CSL method (cross-hole sonic logging)


The CSL method requires protection of the holes over the full pile length; inside them the wave
transmitter and receiver are moving. Hence, the method can be used provided the pile is appropriately
prepared during its execution. It considerably reduces the random nature of testing. It should be
stressed that CSL testing allows for controlling the piles of unlimited length.

2.3. Examining the pile material – core drilling


A progress in development of pile technologies is also related to more and more common use of soil
improvement technologies by its deep mixing with cement paste. Depending on soil grade and mixing
method (mechanical like DSM or CSM or high-pressure like jet-grouting) generated are media of
much diversified strength parameters. What need to be emphasized, the compression strength alone is
not the sole criterion because, for instance, jet-grouted columns made in gravels featuring relatively
high strength (C25/30) are at the same time very porous, which may limit the durability of
reinforcement sunk in them.

Figure 3. Core samples from heads of prefabricated driven piles (left) and DSM columns (right)

4
WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

A typical examination of the pile or column material is the compression test made on core samples. An
important issue is that the samples should be taken from the whole volume of executed pile or column
and not only from their axis where they, to the most degree, represent the strength of the injected
binder. Another problem refers to testing for material strength in prefabricated piles. Obviously, the
subject of testing is not the strength of concrete in the prefabricated pile at the fabrication plant, as this
is the care of manufacturer (usually C40/50), but the strength of pile after it was driven in terms of
possible fractures during transportation and driving. Examinations were made at Wroclaw University
of Technology on core samples cut out of pile heads (about 30 cm from the head) manifested that
concrete strength determined on standard samples was C40/50-C50/60. No fractures in samples were
found which would accelerate their failure in testing machine.

2.4. Length inspection - Parallel Seismic Method


The Parallel Seismic method consists in preparing a hole in soil along the pile where a hydrophone is
placed. Then, using a calibrated hammer a hit is made either to pile head or to top plate of pile group.
The PSI kit (Parallel Seismic Instrument) acc. to Piletest Ltd [18] and the PST kit (Parallel Seismic
Test) made by Testconsult Cinoabt can be found in common practice [18].
The most important advantage of this method seems the possibility of examining the structures
crowned with a top plate, i.e. when the pile head is inaccessible. However, when comparing with the
methods presented above, a big impediment is the necessity to make stabilized hole deeper than the
expected length of the component under survey. A hydrophone is then moved down the hole.
Executing this hole can be connected with geotechnical examinations of the subbase in successive
layers along the pile shaft and beneath the base of the pile being under survey which could then be
used to conclude about its load bearing capacity. The interpretation of PSI (Piletest) testing is given in
figure 4 [18], while scheme of PST kit operation, taken from the website www.testconsult.co.uk [18],
is shown in figure 5.

Figure 4. Functional diagram of Parallel Seismic Instrument Method, Piletest Ltd [18]
1-data reader, 2-calibrated hammer, 3-winch, 4-hydrophone
It is worth noting that such testing allows also for surveying the length of sheet pilings or palisades
crowned with embankment structure. It is of special importance when we need data to make stability
calculations in terms of dredging a channel or enlarging the top load of surcharge (embankment
surface).

5
WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

Figure 5. Functional diagram of Parallel Seismic Testing method by Testconsult [18].

3. Examinations with Osterberg cell (O-cell) and new similar ideas


While analysing the bearing capacity of test loaded piles, when the examinations are to serve not only to
show the margin of test-loaded pile capacity, it is important to separate the capacity of the base and that of the
pile shaft. The solution for executing such examination, technically simple however expensive, is to use an
actuator located in the pile base (base load cell). Measurement of the force and lifting the pile head, while
simultaneously measuring the force applied in its base, allows to get information about pile bearing capacity
and, at the same time, about the bearing capacity distribution to pile base and shaft. The actuator is lost and the
cell space subjects to injection. Detailed description of the method and the rules of analysing the results are
provided in papers [2], 20]. A comprehensive summary (state of the art) of bi-directional testing was given by
England in the works [21].

Figure 6. Actuators secured to pile reinforcement by foundation-alliance [23]

6
WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

Various methods of test data examination are proposed in work of England [21]. Other authors
developed the methods of equivalent load-settlement curve derived on the basis of bi-directional test
[23]. As it was previously mentioned, among all the advantages, the Osterberg test has one major
problem – the hydraulic jacks are sacrificial. The problem may be solved by shifting it to the pile head
and transmitting the force through the piston in the pile vertical axis. Such test require however a
reliable instrumentation for displacement measurements. When the instrumentation is expected to be
removable too, the case becomes even more complicated. Interesting development was recently
published by Baca et al. [6] who examined various surveying techniques (including laser scanning) for
displacement control of “piston-test” which resembles original Hayden [4] and VUIS [3] ideas
adopted for closed end pipe piles.
If the bi-directional test can be combined with standard pile head loading against a reaction frame,
the separation of pile base and pile shaft capacity can be derived. Such sequence of testing was also
reported by Baca et al. [25], who tested the possibility and conditions of cyclic loading of pile toe in
various shaft load conditions.
4. Summary and conclusions
Various inspection techniques provide a possibility of quality and capacity testing of piles. Experiences
suggest that sometimes we can attempt to interpret the results of quality testing for piles with small age or
pretty large slenderness, i.e. the factors for which caution is advised with conclusions. In general, it should be
stated that modern testing technologies create temptation of over interpreting the testing results. Creating a
data base including test load results for piles, at least those which are at the disposal of testing companies
and/or academic centres, seems to be a valuable initiative. Such base would enable to specify local (national)
correlations between static and dynamic testing for various grades of soil and piling technologies. It is of
special importance at the time of introducing the Eurocode 7, which admits (and even prefers) pile designing
on the basis of results from various test loads. Data bases are in practice the sole reliable source of information
for creating respective national appendixes or standards for pile engineering.
There is a big field of possible cooperation between testing companies, who gather test data and
develop the technologies and Universities, where those data should be post-processed with respect to
soil conditions, materials and loading sequence. Those data should also be a subject of exchange
because larger statistic probes can guarantee a synergy of accuracy and lower standard deviations of
estimated results. The authors, representing both sides (contractor/university) are willing to emphasize
one more issue. The research based on real test results will never lead to scientifically correct but
purely nonsense statements, which have no value in contemporary building practice.

Acknowledgements
The authors would like to express their gratitude to AARLEFF Sp. z o.o., METRIS Sp. z o.o. and
colleagues from Technical University in Wroclaw for making available their results of pile testing and
references (private communication).

References
[1] J. Hola, K. Schabowicz, „State-of-the-art non-destructive methods for diagnostic testing of
building structures - anticipated development trends”, Archives of Civil and Mechanical
Engineering, Vol 10, No 3, pp. 5-18, 2010.
[2] J.O. Osterberg, “The Osterberg Load Test Method for Bored and Driven Piles - The First Ten
Years”, 7th International Conference & Exhibition on Piling and Deep Foundations. Deep
Foundation Institute, Vienna, Austria. 1998.
[3] B. Cernak, J. Hlavacek, K. Klein, “A new method of static pile load system VUIS-P”, Proc. of
the 1st International Geotechnical Seminar on Deep Foundations on Bored and Auger Piles,
Ghent, Belgium, 7–10 June 1988. Balkema, Rotterdam, the Netherlands. pp. 291–301, 1988
[4] M. Hayden, “Pile HAY-Proof-System: New test method for static load tests of slender piles”,
Ground Engineering, December 2013, pp. 25-28, 2013.

7
WMCAUS IOP Publishing
IOP Conf. Series: Materials Science and Engineering 245 (2017) 022074 doi:10.1088/1757-899X/245/2/022074
1234567890

[5] Z. Meyer, M. Kowalow, „Statyczny test Osterberga zastosowany dla pali o dużej nośności”,
Osterberg Test applied for large capacity piles, Inżynieria Morska i Geotechnika, No. 3, 427-
431, [In Polish], 2011
[6] M. Baca, Z. Muszyński, J. Rybak, T. Żyrek, “The application of geodetic methods for
displacement control in the self-balanced pile capacity testing instrument”, Advances and
trends in engineering sciences and technologies: proceedings of the International
Conference on Engineering Sciences and Technologies, Tatranská Štrba, Slovakia, CRC
Press, cop. 2016, pp. 15-20. 2015
[7] M. Baca, J. Rybak, T. Żyrek, „Practical aspects of tubular pile axial capacity testing”, 15th
International Multidisciplinary Scientific GeoConference, SGEM 2015, Albena, Bulgaria,
Book 1 Vol. 2, pp. 549-554, 2015
[8] ASTM: D5882-00 “Standard Test Method for Low Strain Integrity Testing of Piles”
[9] NF P 94-160-2: “Auscultation d’un element de fondation. Partie 2: Methode par reflexion”.
Association francaise de normalisation, 1993.
[10] R.J. Finno, S.L. Gassman, “Impulse response evaluation of drilled shafts”. Journal of
Geotechnical and Geoenvironmental Engineering, vol. 124, No. 10, pp. 965–975, 1998
[11] N. Thasnanipan, A.W. Maung, T. Navaneethan, Z.Z. Aye, “Non-destructive integrity testing on
piles founded in Bangkok subsoil” Proceedings of 6th Conference on the application of stress
wave theory to piles, Sao Paulo, Brazil, Balkema, Rotterdam. pp. 171-177, 2000
[12] J.M. Amir, “Wave velocity in young concrete”, Proc 3rd Int. Conf. on Application of Stress-
wave Theory to Piles, Ottawa, pp. 911-912, 1988
[13] C. Restrepo, “Stress wave propagation velocity at early ages”, Proceedings of 6th conference on
the application of stress wave theory to piles, Sao Paulo, Brazil, Balkema, Rotterdam, 2000
[14] E. Niederleithinger, A. Taffe. “Early stage elastic wave velocity of concrete piles”. Cement &
Concrete Composites, vol. 28, pp. 317–320, 2006
[15] J. Rybak, K. Schabowicz, “Acoustic wave velocity tests in newly constructed concrete piles”,
NDE for Safety, 40th international conference and NDT exhibition: proceedings, Brno
University of Technology. Faculty of Mechanical Engineering, pp. 247-254, 2010.
[16] J. Rybak, “Stress wave velocity tests in early-stage of concrete piles” Concrete solutions:
proceedings of Concrete Solutions, 5th International Conference on Concrete Repair,
Belfast, Northern Ireland, CRC Press, Taylor & Francis Group, cop. 2014. pp. 571-576, 2014
[17] E.I. Amir, J.M. Amir, “Statistical analysis of a large number of PEM tests on piles”. Proc. of 8th
conference on the application of stress wave theory to piles, Lisbon, Portugal, IOS Press, pp.
671-675, 2008.
[18] Web sites: http://www.piletest.com, http://www.testconsult.co.uk
[19] J. Schmertmann, J. Hayes, “The Osterberg Cell and Bored Pile Testing – a Symbiosis”.
Proceedings at the Third Annual Geotechnical Engineering Conference. Cairo University,
January 5-8, 1997, Cairo, Egypt, 1997.
[20] P. Velič, P. Mišove, “Statické zaťažovacie skúšky pilót”, Static loading test of piles, Inžinierske
Stavby, No 04, [in Slovak], 2013
[21] M. England, “Review of methods of analysis test results from bi-directional static load tests”,
Proc. of the 5th International Symposium on Deep Foundation on Bored and Auger Piles,
pp. 235-239, 2009.
[22] M. England, “Bi-directional static load test – state of art”, Proc. of the 4th International
Symposium on Deep Foundation on Bored and Auger Piles, pp. 309-313, 2003.
[23] Web site: http://www.foundation-alliance.com
[24] J.-S. Lee, Y.H. Park, „Equivalent pile load-head settlement curve using a bi-directional pile load
test”, Computers and Geotechnics. No. 35, pp. 124–133, 2008
[25] M. Baca, J. Rybak, A.G. Tamrazyan, T. Zyrek, „ Pile foot capacity testing in various cases of
pile shaft displacement”. 16th Int. Multidisciplinary Scientific GeoConference, SGEM 2016,
Albena, Bulgaria, Book 1 Vol. 1, pp. 945-950, 2016

You might also like