You are on page 1of 7

DWG Number 364A2921 Rev J Released 9/17/2014 Page 2 of 4

SIZE DWG NO SH REV


A 364A2921 2 J

3 PH, VAC
SUPPLY

CB
FU-1
PS-270A ***

T1
63QB-2 ***
KTGMAUTO
OIL TANK **

52-TGM
(3)
HS-1 52-TGM
AUTO
49TGM 52-TGM 52-TGM
(3)
4TGM* HS-2
T1 T2 T3 START
STC (RUN)

TGM ** KTGMAUTO
SP-TGM*** 52-TGM
SPACE 3TGMPTK
HEATER A R G
TG-AMM 49TGM
@TGM MOTOR AUTO RUN STOP
4-20Ma
CURRENT THERMOSTAT
TRANSDUCER (IF AVAILABLE)
(See Sht 3)
HS
TO CONTROL
SYSTEM *
(TCP POWERING LOOP)

TO AIR
CUSTOMER'S TO CONTROL TO CONTROL
52-TGM 49TGM 3TGMPTK MOTOR
VAC 1PH SYSTEM * SYSTEM * CIRCUIT
SOURCE
52-TGM
CONTROL SWITCH POSITION (HS)
Turn to maintain in all positions
** - Supplied by GEPS product group KTGMAUTO TO CONTROL
START
X - Indicates Closed Contacts SYSTEM * STOP AUTO
(RUN)
* - Control System Contacts
***- Required if listed in VE14 1 X
Control Switch contacts shown in Auto Position 2 X
Relay contacts shown in Normal Shelf State
3

g
GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
SCHENECTADY, NY

GE Power Generation
DRAWN
Bruce R. Kretser 2004-03-03
A 364A2921
ISSUED SCALE SHEET
Bruce R. Kretser 2004-03-03 2 OF 4

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 364A2921 Rev J Released 9/17/2014 Page 4 of 4
SIZE DWG NO SH REV
A 364A2921 4 J

3 PH, VAC (With Control System Profibus Interface to Motor Management System)
SUPPLY

A***
CB OIL **
FU-1 TANK

B ***

MOTOR MANAGEMENT PROFIBUS


SYSTEM LOGIC
52-TGM
(3)
LOCAL
STOP
L1/1 L2/3 L3/5 TGM-SS ***
SOFT 52-TGM
STARTER C* LOCAL
T1/2 T2/4 T3/6 STC START

52-TGM

THERMAL
OVERLOAD

CT 3TGMPTK
INPUTS CONTACT
INPUTS
CONTACT
OUTPUTS
T1 T2 T3

TGM **
SP-TGM***
MOTOR
SPACE
THERMOSTAT
HEATER (IF AVAILABLE)

** - Supplied by GEPS product group


CUSTOMER'S
* - Control System Contacts
VAC 1PH ***- Required if listed in VE14
SOURCE
52-TGM
Local Control contacts shown in “Auto” Position

CONTACT INPUTS PROFIBUS INPUTS


CONTACT OUTPUTS PROFIBUS OUTPUTS
A *** B *** C*

PS-270A 63QB-2 4TGM 52-TGM 3TGMPTK KTGMAUTO 52-TGM 49TGM

g
GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
SCHENECTADY, NY

GE Power Generation
DRAWN
Bruce R. Kretser 2004-03-03
A 364A2921
ISSUED SCALE SHEET
Bruce R. Kretser 2004-03-03 4 OF 4

GE Proprietary Information - Class II (Internal) US EAR - NLR


DWG Number 121T9983 REV C Released 2017/11/21 Page 74 of 227
LOCATION - COMBINE
LUBE AND HYDRAULIC
JUNCTION BOX
JB/21
(KKS TAG# MAV01 GH021)

(MAV01 GH021)
LOW BRG MOTOR
JUNCT. BOX
LIFT OIL SUPPLY CONTROL
JB/21 CENTER
PRESS.ALARM
63QB-2 TBL4
(MAV53 CP302)
1 TO
NO1 C1 TURNING
SHOWN TBL4
NC1 GEAR
LOW
PRESSURE CIRCUIT
2
SEE
TBL4
TGM REC. CKT.
CABLE SPEC REFER TO VE19
3
LEVEL 3

TBL4

4
NO2 C2
SHOWN TBL4
NC2 LOW PS-270A
PRESSURE SPARE - FOR
5 CUSTOMER USE
TBL4

MOTOR CONTROL
TURBINE JUNCTION CUSTOMER
CENTER
BOX SIDE WIRING
CABINET SIDE
© COPYRIGHT 2016 - 2017 General Electric Company (USA)
All rights reserved. The information herein is Proprietary and Technically Exclusive content that is solely owned by General Electric Company and/or its affiliates.
CREATOR: APROVED BY: DOCUMENT TYPE REVISION

BRUCE KRETSER JAMES ANTALEK CUSTOMER DRAWING C

g
DOCUMENT TITLE

T / G CONTROLS INTERCONNECTION DIAGRAM


GE Power
CREATION DATE: (YYYY-MM-DD) SHEET SIZE DRAWING NUMBER SHEET NUMBER

2016-05-19 A 121T9983 13-27


GE Proprietary Information - Class II (Internal) US EAR - NLR
DWG Number 121T9983 REV C Released 2017/11/21 Page 215 of 227
LOCATION -
TURNING GEAR

TURNING TGM
GEAR BOX
MOTOR
T1
TGM T5
(MAK01 AE001-M01) T4
T2
TO MOTOR
M CONTROL CENTER
T6 WIRED BY CUSTOMER
T7 T3 CT1
T8 BY SEE DEVICE DATA LIST
GND FOR MOTOR RATINGS
SPACE T9 CUST.
HEATER *
SP-TGM REFER TO VE19
(MAK01 AE001-R01) RECOMMENDED
H1 CIRCUIT

H2

THERMOSTATS P1
P2

T3 T1

T6 T9 T7 T4

T8
T5

T2
CONNECTION 2Y/1Y - VOLTAGE RATIO 1/2

VOLTS L1 L2 L3 TOGETHER

2Y LOW T1-T7 T2-T8 T3-T9 T4-T5-T6


* NAMEPLATE DATA FOR
JUMPER CONNECTIONS T4-T7
1Y HIGH T1 T2 T3 T5-T8
T6-T9

© COPYRIGHT 2016 – 2017 General Electric Company (USA)


All rights reserved. The information herein is Proprietary and Technically Exclusive content that is solely owned by General Electric Company and/or its affiliates.
CREATOR: APROVED BY: DOCUMENT TYPE REVISION

BRUCE KRETSER JAMES ANTALEK CUSTOMER DRAWING C

g
DOCUMENT TITLE

T / G CONTROLS INTERCONNECTION DIAGRAM


GE Power
CREATION DATE: (YYYY-MM-DD) SHEET SIZE DRAWING NUMBER SHEET NUMBER

2016-05-19 A 121T9983 30-1


GE Proprietary Information - Class II (Internal) US EAR - NLR
DWG Number 121T9983 REV C Released 2017/11/21 Page 216 of 227
LOCATION -
MOTOR CONTROL
CENTER

(CJJ10 GH001)

CUSTOMER'S STC CABINET


TURNING GEAR MCC D
MOTOR STATUS
TDBT-TB2 PDIO
(SEE TABLE 'A' BELOW)
B + VDC

TDBT-TB2

CABLE SPEC
LEVEL 3

MOTOR CONTROL CUSTOMER STC


CENTER SIDE WIRING CABINET SIDE

TURNING GEAR MOTOR STATUS STC (CJJ10 GH001)


A B C D

KTGMAUTO 17 18 1M2A

52-TGM 15 16 1M2A

49-TGM 13 14 1M2A

© COPYRIGHT 2016 – 2017 General Electric Company (USA)


All rights reserved. The information herein is Proprietary and Technically Exclusive content that is solely owned by General Electric Company and/or its affiliates.
CREATOR: APROVED BY: DOCUMENT TYPE REVISION

BRUCE KRETSER JAMES ANTALEK CUSTOMER DRAWING C

g
DOCUMENT TITLE

T / G CONTROLS INTERCONNECTION DIAGRAM


GE Power
CREATION DATE: (YYYY-MM-DD) SHEET SIZE DRAWING NUMBER SHEET NUMBER

2016-05-19 A 121T9983 30-2


GE Proprietary Information - Class II (Internal) US EAR - NLR
DWG Number 121T9983 REV C Released 2017/11/21 Page 217 of 227
LOCATION - MOTOR
CONTROL CENTER

(CJJ10 GH001)
4TGM
MOTOR STC CABINET RUN COMMAND
CTRL CENTER 1M2A
TDBT-TB1 PDIO
39
SHOWN NOT
TURNING GEAR TDBT-TB1 RUNNING
MOTOR
RUN COMMAND 38

TDBT-TB1
CABLE SPEC 37
LEVEL 3

(CJJ10 GH001)

MOTOR STC CABINET


CTRL CENTER 1A2B
SHRA PHRA
TGCUR
(TG MEASURED CURRENT) 13 + VDC

TURNING GEAR
SHRA
MOTOR
CURRENT
14 4-20MA
TRANSFORMER

LOW SHIELD BUS


CABLE SPEC
LEVEL 1

MOTOR CONTROL CUSTOMER STC


CENTER SIDE WIRING CABINET SIDE

© COPYRIGHT 2016 – 2017 General Electric Company (USA)


All rights reserved. The information herein is Proprietary and Technically Exclusive content that is solely owned by General Electric Company and/or its affiliates.
CREATOR: APROVED BY: DOCUMENT TYPE REVISION

BRUCE KRETSER JAMES ANTALEK CUSTOMER DRAWING C

g
DOCUMENT TITLE

T / G CONTROLS INTERCONNECTION DIAGRAM


GE Power
CREATION DATE: (YYYY-MM-DD) SHEET SIZE DRAWING NUMBER SHEET NUMBER

2016-05-19 A 121T9983 30-3


GE Proprietary Information - Class II (Internal) US EAR - NLR
0 1 2 3 4 5 6 7 8 9

-L1_R
21.9 /L1_R -L2_R
L1_R / 23.0
21.9 /L2_R -L3_R
L2_R / 23.0
21.9 / L3_R L3_R / 23.0
21.9 / N_R N_R / 23.0
-PE_R
21.9 / PE_R PE_R / 23.0
21.9 / 110VDC+ 110VDC+ / 23.4
PE 21.9 / 110VDC- 110VDC- / 23.4
22.1 21.2 / 230VN

-P07_02 21.2 / 230VL


L1 L2 L3 A1 A2 A3 A4
P A
1/L1 3/L2 5/L3

1 1
I> I> I> -F1
C 6A 10kA
-Q1 2/T1 4/T2 6/T3
2 2
63A, N: 819, 100kA -F2
SIEMENS SIEMENS C 10A 10kA

SIEMENS
SIE.5SY5110-7
3RV1342-4JC10 SIE.5SL4106-7
13
3RV1901-1E
3RA1941-1AA00 -Q1
/22.0 14
13

14

3SB3610-2DA11
/22.4

SIEMENS
COM COM 11 21 41 13
RK1 RA1 K1 K1
-20S1 AUTO START /22.5 14 12 /22.4 24 22 /22.5 42 /22.5 14

1 3 5 31
-K1 K1
/22.5 2 4 6 /22.5 32
37 kW

-RDCS1
/22.7
11

12 14

-TR1

SIE.3RT1045-1BF40
3RB2987-2B

A1 A2 96/05 98/07

3RH1921-1FA22
+ -

LZXPT570110

LZXPT570110

LZXPT570110
SIEMENS
SIEMENS

SIEMENS

SIEMENS
-E1 L1 L2 L3
98 05 96 07
10...100A Sys Sys

97 06 95 08 A1 A1 A1 A1
SIEMENS
3RB2906-2JG1 SIEMENS

LZXPT570110
3RB2283-4AA1 -RA1 A2 -K1 A2 -RK1 A2 -RPTK A2

3SB3604-6BA30

3SB3604-6BA40

3SB3604-6BA20

SIEMENS
-RDCS1
3RB2985-2CB1

SIEMENS

SIEMENS

SIEMENS
T1 T2 I(+) I(-) 95 06 97 08

-RTR1
/22.3
11 x1 x1 x1 A2 13 11 21 31
A1 -RTR1 K1 -RA1 -RPTK
/22.3 -H1 x2 -H2 x2 -H3 x2 /22.5 /22.4 /22.5
-RTR1 14 12 A1 14 14 12 24 22 34 32
Yellow Green Red
A2
Auto Stop Start
SIEMENS
LZXPT570110

P A A A7 A8
B
L1 L2 L3 A5 A6 D1 D2 D3 D4 D5 D6 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10
PE
22.0 dummy terminal
Cabinet -P07_02
Field area
-WP_H_10MAK01AE001M

-WP_T_10MAK01AE001M

OIL_TANK
-WP_10MAK01AE001M
63QB-2

U1 V1 W1 PE PS-270A -XDCS
x1
Control
BLOCK 10 TURNING GEAR M 14 11 /22.8 14 11 /22.5 34 31 /22.9 To Control To Control To Control To Control
-XDCS 12 12 32 System
MOTOR 3 24 21 /22.6 System System System System
30 kW x2 Contact
54,19A
To Control 22

HEATER System
- +
1 2 /22.0
3 4 /22.0 14 11 /22.5
THERMISTOR 5 6 /22.1 12
14 11 /22.4
12 13 14 /22.7
24 21 /22.8 13 14 /22.7
22 31 32 /22.1
41 42 /22.6

21 23
Date 30.11.2017
170917_CALIK_ENERJI_MARY3_LOT3 = BLOCK_10_ST_LV_ESS_SWGR + P07
Ed. MURAT KARAKELLE ++ MRC_18_BF_EDC_EGE_202
P07 BLOCK 10 TURNING GEAR MOTOR
Appr LEVENT YAVAŞ Page 22
170917
Modification Date Name Original www.egesim.com Page 70