The GLA Limit Switch Series with standard or plug-in housings
(EN50041 design, with 30 mm x 60 mm mounting) complement
the smaller GLC Series, GLD Series and GLE Series (EN50047
design, with 20 mm to 22 mm mounting). The GLA Series is part
of the MICRO SWITCH™ Limit Switch Series that includes the
HDLS Series (Heavy Duty Limit Switch) and General Purpose
Limit Switch (LS) Series.
Table 1. Specifications
Characteristic Parameter
Description EN50041 industrial grade limit switch, standard body or plug-in body with 30 mm x 60 mm mounting
Certifications CE, CCC, CSA, UL
Conforming to standards IEC/EN 60947-5-1, EN45545-2 (GLA/GLF Series)
Housing material Electrostatic epoxy coated zinc
Side rotary, top pin plunger, top adjustable plunger, top roller plunger, top roller lever,
Actuators
wobble stick (multi-directional) actuator, cat whisker (multi-directional) actuator
0.5-14 NPT; PG 13,5; M20; G 1/2 (PF 1/2); Deutsch style 4-pin connector; Micro-change connector; Mini-
Termination
change connector; Pre-cabled
Contact options* 1NC/1NO, 2NC, 2NO, 2NC/2NO, 2NC/2NO sequential, 2NC/2NO center neutral
Contact type Snap action, slow action break-before-make (BBM), slow action make-before-break (MBB), slow action
Contact material Silver alloy (standard), gold-plated (low-energy applications)
Utilization category ac15, A300/A600; dc13, Q300
Rated operational voltage
240 Vac, 600 Vac, 250 Vdc
(Ue)
Rated operational current (Ie) 3 A, 1.2 A, 0.27 A
Thermal current (Ith) 10 A, 2.5 A
Rated insulation voltage (Ui) 300 V; 600 V
Rated impulse withstand
2500 V
voltage (Uimp)
Short circuit protective device
Class J fuse, rated 10A, 600 V
(SCPD), type, and rating
Pollution degree 3
Sealing IP67; NEMA/UL 1, 4, 12, and 13
-40 °C to 85 °C [-40 °C to 185 °F] side rotary actuator
Operating temperature
-25 °C to 85 °C [-13 °F to 185 °F] other actuators
Mechanical life Up to 15 million operations
Vibration (actuator not fitted) 10 g conforming to IEC 68-2-6
Shock (actuator not fitted) 50 g conforming to IEC 68-2-27
Standard limit switch with 1 LED pilot light (GLF Series) or 2 LED pilot lights (GLH Series) in front cover
Options
Plug-in limit switch with 1 LED pilot light (GLG Series) in front cover
*Normally closed (NC) contacts are positive opening except for the center neutral limit switches
2 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
GL A A 01 A E7B
Body Style
Switch Type (EN50041) Conduit Basic Switch Heads Actuators or Levers*
GL Series 0.5-14 1NC/1NO, SPDT 2NC/2NO, 38 mm fixed, 38 mm fixed 150 mm x CW actuation
Global A Non plug-in A NPT 01 snap action 20 DPDT
snap action
A Side rotary 1A 19 x 6 nylon
roller
3 yoke, no
rollers
7A Ø6,4 mm
plastic rod
1 only
Non plug-in 1NC/1NO, 2NC/2NO, DPDT, Top roller 38 mm fixed, Adjustable 140 mm x Head with lever
H with 2 LED
pilot lights
03 SPDT, BBM,
slow action
21 snap action,
sequential
D lever, nylon
19 x 8 mm roller
1Y 50 x 10 rubber
roller
4K aluminum rod,
140 mm max.
8A Ø1,2 mm
SST wire
5 to mounting
surface
1NC/1NO, SPDT, 2NC/2NO, DPDT, Top 38 to 93 mm Adjustable 190 mm x Roller plunger
33 BBM, slow action,
gold contacts
28 snap action, gold
contacts, sequential
H adjustable
plunger
2A adjustable, 19 x
6 nylon roller
4N SST rod,
318 mm max.
8B Ø1,2 mm
SST wire
6 perpendicular
to mtg. surface
2NC/2NO, DPDT, 38 to 93 mm 38 mm fixed 141 mm x
1NC/1NO, SPDT,
04 MBB, slow action 25 snap action,
LED, sequential
E Wobble stick 2B adjustable, 19 x
6 steel roller 5A offset, 19 x 6
nylon roller
8C Ø6,7mm
SST coil spring
1NC/1NO, SPDT, 2NC/2NO, DPDT, 38 to 93 mm 38 mm fixed
Cat
34 MBB, slow action, 31 snap action, gold
contacts, LED, K whisker 2D adjustable, 38 x 5B offset, 19 x 6
gold contacts sequential 5 nylon roller steel roller
2NC/2NO, DPDT, 38 to 93 mm
05 2NO,
slow action 26 snap action, 2W adjustable, 38 x
12 rubber roller
center neutral
2NO, 2NC/2NO, DPDT, 38 to 93 mm
35 slow action,
gold contacts
29 snap action, gold
contacts, 2Y adjustable, 50 x
10 rubber roller
center neutral
2NC, 2NC/2NO, DPDT, * Levers beginning with codes 1 to 5 are for A and J style side rotary heads only.
06 slow action 27 snap action, LED,
center neutral
Actuators beginning with Code 7 are for E style wobble stick head only.
Actuators beginning with Code 8 are for K style cat whisker head only.
2NC, 2NC/2NO, DPDT,
36 slow action,
gold contacts
30 snap action, LED,
center neutral, gold
contacts
**NOTE: Basic switch codes 02 and 12 may only be used
with body styles B and G.
Operating Torque
Contact Material
max. Nm [in-lb]
Head and Lever
Contact Type
0.5-14 NPT 20 mm
Bar Chart (degrees) Conduit Conduit
Contact
Light/s
¢ contact closed
Type
£ contact open
26° 55°** 85°
Silver 0,33 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01A GLAC01A
alloy [2.9] 12° Differential travel
26° ** 85°
Slow action, Silver 0,33 21-22
1NC/1NO 13-14 – – GLAC03A
BBM alloy [2.9] 38°
38° ** 85°
Side Slow action, Silver 0,33 21-22
1NC/1NO 13-14 – GLAA04A –
rotary, MBB alloy [2.9] 26°
0° 16°
2NC/2NO † 11-12 >
Silver 0,33 13-14 <
Center Snap action ‡ 21-22 >
< – GLAA26J –
alloy [2.9] 23-24
neutral 8° Differential travel
8° Differential travel
0° 16°
2NC/2NO † 11-12 >
Gold- 0,33 13-14 <
Center Snap action ‡ 21-22 >
< – GLAA29J –
plated [2.9] 23-24
neutral 8° Differential travel
8° Differential travel
0° 16°
2NC/2NO † 11-12 >
Silver 0,33 13-14 <
Center Snap action ‡ 21-22 >
< – GLAA26J1A –
alloy [2.9] 23-24
neutral 8° Differential travel
8° Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
† Contacts 11-12, 13-14 operate in CCW direction. ‡ Contacts 21-22, 23-24 operate in CW direction.
4 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
Table 3. MICRO SWITCH™ GLA Series Side Rotary Order Guide, continued
Catalog Listing*
Operating Torque
Contact Material
max. Nm [in-lb]
Head and Lever
Contact Type
0.5-14 NPT 20 mm
Bar Chart (degrees) Conduit Conduit
Contact
Light/s
¢ contact closed
Type
£ contact open
26° 55°** 85°
Silver 0,33 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01A1B GLAC01A1B
alloy [2.9] 12° Differential travel
26° ** 85°
Slow action, Silver 0,33 21-22
1NC/1NO 13-14 – GLAA03A1B –
BBM alloy [2.9] 38°
38° ** 85°
Slow action, Silver 0,33 21-22
1NC/1NO 13-14 – GLAA04A1B –
MBB alloy [2.9] 26°
0° 16°
2NC/2NO † 11-12 >
Silver 0,33 13-14 <
Center Snap action ‡ 21-22 >
< – GLAA26J1B –
alloy [2.9] 23-24
neutral 8° Differential travel
8° Differential travel
0° 16°
2NC/2NO † 11-12 >
Gold- 0,33 13-14 <
Center Snap action ‡ 21-22 >
< – GLAA29J1B –
plated [2.9] 23-24
neutral 8° Differential travel
8° Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
† Contacts 11-12, 13-14 operate in CCW direction. ‡ Contacts 21-22, 23-24 operate in CW direction.
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Nm [in-lb]
Bar Chart (degrees)
¢ contact closed
£ contact open
26° 55°** 85°
Silver 0,33 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01A2A GLAC01A2A
alloy [2.9] 12° Differential travel
0° 16°
2NC/2NO † 11-12 >
Silver 0,33 13-14 <
Center Snap action ‡ 21-22 > – GLAA26J2B –
alloy [2.9] 23-24 <
neutral 8° Differential travel
8° Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs. † Contacts 11-12, 13-14 operate in CCW direction. ‡ Contacts 21-22, 23-24 operate in CW direction.
6 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
Table 3. MICRO SWITCH™ GLA Series Side Rotary Order Guide, continued
Catalog Listing*
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Nm [in-lb]
Bar Chart (degrees)
¢ contact closed
£ contact open
Side
rotary,
adjust-
able 26° 55°** 85°
Silver 0,33 21-22 >
lever, 1NC/1NO Snap action 13-14 < – GLAA01A2Y –
alloy [2.9]
Ø 50 12° Differential travel
mm
rubber
roller
26° 55°** 85°
Silver 0,33 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01A4J GLAC01A4J
alloy [2.9] 12° Differential travel
38° ** 85°
Slow action, Silver 0,33 21-22
1NC/1NO 13-14 – GLAA04A4J –
MBB alloy [2.9] 26°
Side
rotary, Silver 0,33 11-12, 21-22
26° 55°** 85°
>
adjust- 2NC/2NO Snap action 13-14, 23-24 < – GLAA20A4J –
alloy [2.9] 12° Differential travel
able alu-
minum Gold- 0,33 11-12, 21-22
26° 55°** 85°
>
rod 2NC/2NO Snap action 13-14, 23-24 < – GLAA22A4J –
plated [2.9] 12° Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
Catalog Listing*
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Nm [in-lb]
Bar Chart (degrees)
¢ contact closed
£ contact open
fixed off-
set lever,
26° 55°** 85°
nylon Silver 0,33 11-12, 21-22 >
2NC/2NO Snap action 13-14, 23-24 < – GLAA20A5A –
roller alloy [2.9] 12° Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Head Type
¢ contact closed
£ contact open
37.5 35 33** 30.5
Silver 16 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01B GLAC01B
alloy [3.6] 0.9 Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
8 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Head Type
N [lb]
¢ contact closed
£ contact open
50.5 48 46** 43.5
Silver 16 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01C GLAC01C
alloy [3.6] 0.9 Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit..
** Positive opening occurs.
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Head Type
N [lb]
¢ contact closed
£ contact open
Wobble
stick, 18° 35°
Silver 0,2 21-22 >
150 mm 1NC/1NO Snap action 13-14 < – GLAA01E7A –
alloy [1.8]
plastic 8° Differential travel
rod
18° 35°
Silver 0,2 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01E7B GLAC01E7B
alloy [1.8] 8° Differential travel
18° 35°
Silver 0,2 21-22 > 1 LED
1NC/1NO Snap action 13-14 < GLFA01E7B GLFC01E7B
alloy [1.8] 8° Differential travel
(yellow)
18° 35° 2 LEDs
Silver 0,2 21-22 >
1NC/1NO Snap action 13-14 < (green & GLHA01E7B –
Wobble alloy [1.8] 8° Differential travel yellow)
stick, 18° 35°
141 mm Gold- 0,2 21-22 >
1NC/1NO Snap action 13-14 < – – GLAC07E7B
sst coil plated [1.8] 8° Differential travel
spring
18° 35°
Slow action, Silver 0,2 21-22 >
1NC/1NO 13-14 < – – –
BBM alloy [1.8] 25°
18° 35°
Silver 0,2 11-12, 21-22 >
2NC/2NO Snap action 13-14, 23-24 < – GLAA20E7B GLAC20E7B
alloy [1.8] 8° Differential travel
18° 35°
Silver 0,2 11-12, 21-22 > 1 LED
2NC/2NO Snap action 13-14, 23-24 < GLFA24E7B –
alloy [1.8] 8° Differential travel (yellow)
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
10 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Head Type
N [lb]
¢ contact closed
£ contact open
Cat 18°
whisker, Silver 0,1 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01K8A –
140 mm alloy [0.9] 8° Differential travel
sst wire
18°
Silver 0,1 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01K8B –
alloy [0.9] 8° Differential travel
Cat
whisker,
190 mm
sst wire
18°
Silver 0,1 11-12, 21-22 >
2NC/2NO Snap action 13-14, 23-24 < – GLAA20K8B GLAC20K8B
alloy [0.9] 8° Differential travel
18°
Silver 0,1 21-22 >
1NC/1NO Snap action 13-14 < – GLAA01K8C –
alloy [0.9] 8° Differential travel
Cat
whisker,
141 mm
sst coil
spring 18°
Silver 0,1 11-12, 21-22 >
2NC/2NO Snap action 13-14, 23-24 < – GLAA20K8C –
alloy [0.9] 8° Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
Table 7. MICRO SWITCH™ GLA Series Top Roller Lever Order Guide
Catalog Listing*
Contact Material
Operating Force
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
max. N [lb]
Head Type
65,2 61 56,9** 52
Silver 9,5 21-22 > 1 LED
1NC/1NO Snap action 13-14 < GLFA01D –
alloy [2.1] 1,7 Differential travel
(yellow)
Top 65,2 59,1** 52
roller Slow action, Silver 9,5 21-22 >
1NC/1NO 13-14 < – GLAA04D –
lever MBB alloy [2.1] 61
65,2 61 56,9** 52
Silver 9,5 11-12, 21-22 >
2NC/2NO Snap action 13-14, 23-24 < – GLAA20D GLAC20D
alloy [2.1] 1,7 Differential travel
65,2 61 56,9** 52
Gold- 9,5 11-12, 21-22 >
2NC/2NO Snap action 13-14, 23-24 < – GLAA22D GLAC22D
plated [2.1] 1,7 Differential travel
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
12 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
Table 8. MICRO SWITCH™ GLB Series Side Rotary Order Guide (Plug-in Body)
Catalog Listing*
Contact Material
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Head Type
Nm [in-lb]
Bar Chart (degrees)
¢ contact closed
£ contact open
Side 26° 55°** 85°
Silver 0,33 21-22 >
rotary, 1NC/1NO Snap action 13-14 < – GLBA02A GLBC02A
alloy [2.9]
no lever 12° Differential travel
Side
rotary, 26° 85°
55°**
fixed Silver 0,33 21-22 >
1NC/1NO Snap action 13-14 < – GLBA02A1A –
lever, alloy [2.9] 12° Differential travel
nylon
roller
Side 26° 55°** 85°
Silver 0,33 21-22 >
rotary, 1NC/1NO Snap action 13-14 < – GLBA02A1B GLBC02A1B
alloy [2.9]
fixed 12° Differential travel
Side
rotary,
adjust- 26° 55°** 85°
Silver 0,33 21-22 >
able 1NC/1NO Snap action 13-14 < – GLBA02A2A GLBC02A2A
alloy [2.9]
lever, 12° Differential travel
nylon
roller
Side 26° 55°** 85°
rotary, Silver 0,33 21-22 >
1NC/1NO Snap action 13-14 < – GLBA02A2B GLBC02A2B
adjust- alloy [2.9] 12° Differential travel
able
lever, Silver 0,33 21-22
26° 55°** 85°
> 1 LED
steel 1NC/1NO Snap action 13-14 < GLGA12A2B –
alloy [2.9] 12° Differential travel
(yellow)
roller
26° 55°** 85°
Side Silver 0,33 21-22 >
1NC/1NO Snap action 13-14 < – GLBA02A4J GLBC02A4J
rotary, alloy [2.9] 12° Differential travel
adjust-
able 26° 55°** 85°
alumi- Silver 0,33 21-22 > 1 LED
1NC/1NO Snap action 13-14 < GLGA12A4J –
num rod alloy [2.9] 12° Differential travel
(yellow)
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
Table 9. MICRO SWITCH™ GLB Series Top Plunger Order Guide (Plug-in Body)
Catalog Listing*
Contact Type
Conduit Conduit
Contact Mtl
Head Type
N [lb]
¢ contact closed
£ contact open
37.5 35 33** 30.5
Silver 16 21-22 >
1NC/1NO Snap action 13-14 < – GLBA02B GLBC02B
alloy [3.6]
Top pin 0.9 Differential travel
Table 10. MICRO SWITCH™ GLB Series Top Roller Lever Order Guide (Plug-in Body)
Catalog Listing*
0.5-14 NPT 20 mm
Contact Type
Conduit Conduit
Contact Mtl
Head Type
¢ contact closed
£ contact open
65,2 61 56,9** 52
Silver 9.5 11-12, 21-22 >
1NC/1NO Snap action 13-14, 23-24 < – GLBA02D GLBC02D
alloy [2.1] 1,7 Differential travel
Top
roller
lever 65,2 61 56,9** 52
Silver 9.5 11-12, 21-22 > 1 LED
1NC/1NO Snap action 13-14, 23-24 < GLGA12D –
alloy [2.1] 1,7 Differential travel (yellow)
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit.
** Positive opening occurs.
14 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
Table 11. MICRO SWITCH™ GLB Series Wobble Order Guide (Plug-in Body)
Catalog Listing*
Contact Type
Conduit Conduit
Contact Mtl
Head Type
N [lb]
¢ contact closed
£ contact open
Wobble
stick, 18° 35°
Silver 0,1 21-22 >
150 mm 1NC/1NO Snap action 13-14 < – GLBA02E7A –
alloy [0.9]
plastic 8° Differential travel
rod
18° 35°
Wobble Silver 0,1 21-22 >
1NC/1NO Snap action 13-14 < – GLBA02E7B GLBC02E7B
stick, alloy [0.9] 8° Differential travel
141
18° 35°
mm coil Silver 0,1 21-22 > 1 LED
spring 1NC/1NO Snap action 13-14 < GLGA12E7B –
alloy [0.9] 8° Differential travel
(yellow)
spring
* Note: When conduit style G1/2 (PF1/2) is required, change the 4th digit in the catalog listing to the letter D. For example, GLAA01A1A would change to GLAD01A1A for
G1/2 conduit. When conduit style PG13,5 is required, change the 4th digit in the cagalog listing to the letter B. For example, GLAA01A1A would change to GLAB01A1A for
PG13,5 conduit..
70,00
MAX 38,1 mm
2,756
1.50 in
20,0 mm
0.79 in LEVER ROLLER X DIM Y DIM Z DIM
(catalog listing) MATL
19,1 55,9 6,4
GLZ51A NYLON
.75 2.20 .25
19,1 55,9 6,4
GLZ51B STEEL .75 2.20 .25
62,0 mm 102,9 mm
24,5 59,1 12,7
2.44 in 4.05 in GLZ51C NYLON 2.33 .50
60,0 mm 82,0 mm 1.00
2.36 in 3.23 in 50,0 66,1 10,0
GLZ51Y RUBBER 1.97 2.60 .39
75,8 mm
2.99 in STAINLESS 19.1 56.8 8.8
7,3 mm GLZ51T STEEL .75 2.24 .345
0.29 in
CONDUIT
ENTRY
Ø 5,3 mm
Ø 0.21 in
5,3 mm
0.21 in
16,0 mm
30,0 mm 0.63 in
1.18 in 31,5 mm
1.24 in
42,0 mm
1.65 in 42,0 mm
1.65 in
Figure 3. Fixed Lever, Side Rotary Switch - Plug-in Body Style, GLZ51 Style Lever, and GLB Body
6,4 mm
[0.25 in]
55,9 mm
[2.20 in]
50,0 mm
Ø 19,1 mm [1.97 in]
[Ø 0.75 in]
38,1 mm
70,00 mm max. [1.50 in]
[2,756 in max.]
20,0 mm
[0.79 in]
102,9 mm
[4.05 in]
60,0 mm 69,7 mm
[2.36 in] [2.74 in]
75,8 mm 62,0 mm
[2.99 in] [2.44 in]
7,3 mm
[0.29 in]
CONDUIT
ENTRY
Ø 5,3 mm
[Ø 0.21 in]
5,3 16,0 mm
[0.63 in]
31,5 mm
30,0 mm
[1.24 in]
[1.18 in]
42,0 mm 41,5 mm
[1.65 in] [1.63 in]
16 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
ØX Z
6,5 mm
[0.26 in]
Ø 3,2 mm
[Ø 0.13 in]
59,2 mm
[2.33 in]
Ø 12,4
37,5 [Ø 0.49]
[1.48]
50,5
[1.99]
16,0
7,9 [0.63]
13,0 [0.31]
[0.51]
14,0
[0.55]
65,2
Ø 18,7 [2.57]
[Ø 0.74]
35,0
[1.38]
18 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
16,0 mm Ø6,4 mm
Plastic tip
[0.63 in] [Ø0.25 in]
Cable
Plastic
141,1 mm
[5.55 in]
150,3 mm 153,5 mm
[5.92 in] [6.04 in]
Refer to Figure 2 or 3 for other dimensions Refer to Figure 2 or 3 for other dimensions
5.5 inches (stainless steel) 6.5 inches (stainless steel) 7.5 inches (stainless steel)
Ø1,2 mm
[Ø0.05 in]
Ø1,3 mm
[Ø0.05 in]
Ø1,2 mm
[Ø0.05 in]
190,5 mm
[7.5 in]
165,1 mm
[6.50 in]
139,7 mm
[5.50 in]
REPLACEMENT INSTRUCTIONS
All levers for side rotary assemblies are available as replacment
parts. All basics, except the plug-in, can be replaced. All EN
50041 heads can be replaced. The replacement procedures for
these components are straightforward in nature.
Side Rotary Levers
Remove the lever from the product being replaced. On EN 50041
product this is achieved by loosening the Allen screw holding the
There are two lever mounting options:
lever on the shaft. Replace the lever and tighten the Allen screw
1. By fully seating the lever in one of the four 90° detent posi-
or combination screw. Re-test the switch in its application.
tions on the shaft hub which provides positive lever retention.
2. By mounting the lever on the serrated portion of the shaft Heads
(which enables the lever to be mounted in any position). All EN 50041 style switch heads can be removed and replaced.
To change the rotary lever’s free position: 1. Remove the head by unscrewing the four retaining screws on
1. Use a 3 mm hex Allen wrench to loosen the Allen screw, as the head assembly.
shown in Figure 13, below. 2. Ensure replacement part is identical to one being removed.
2. Back off the lever 2 mm and move it to the desired free 3. Re-test the assembly and ensure correct operation.
position. Basic Switches
3. Retighten the Allen screw. Non-plug-in
4. Check to see if the free position is satisfactory for the Basic switches can be removed and replaced by following this
application. procedure:
5. Repeat the adjustment procedure if necessary. 1. Remove the cover from the body.
A teller tab located at the bottom of the lever (see diagram below) 2. Before disconnecting the switch wiring, carefully note the
helps prevent lever slippage. It enables the installer to detect the wiring arrangement for your application, particularly the safety
correct tightening torque. When this tab cannot be moved, the ground connection.
Allen screw has been tightened properly. 3. Remove the basic switch retaining screw.
4. Remove the basic switch and install the replacement basic
Figure 13. Allen Screw and Teller Tab Location switch.
5. Use the retaining screw to install the new basic switch –
ensure that it is correctly seated in the switch body.
6. Wire the switch terminals as before.
7. Before replacing the cover – ensure that the basic switch
wires are not twisted or otherwise lifted from the basic switch
EN 50041 Side Rotary Actuator Direction Adjustment (to prevent them from becoming trapped when the cover is
As furnished, GLS rotary switches will operate when the lever is replaced).
rotated from either the left or right. They can be field modified to 8. Test the switch in its application.
operate in one direction only (Clockwise CW; Counter clockwise
Figure 15. Retaining screw location
CCW) by following these steps:
1. Carefully remove the complete head assembly.
2. Turn the head assembly upside down as shown in Figure 14.
3. Pull the plunger mechanism out and rotate it through 90°
increments until the alignment tab points to the desired func-
tion (CW, CCW, or CW and CCW).
4. Push plunger mechanism in.
5. Reassemble the head assembly and re-test the switch in its
application.
20 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
LED WIRING
The GLF, GLG, and GLH versions of GLS (EN 50041) come
complete with LED indicators. These indicators can be wired in a In Figure 17, Wiring Diagram 2, the basic switch contact is
variety of ways. Operation can indicate switch free or switch closed. The current for the LED cannot flow through the LED and
operated depending on the wiring arrangement employed. The the LED will not illuminate.
table below indicates the body styles and indicators offered.
Figure 18. Wiring Diagram 3
Table 12. LED Series
Body Function Specification
GLF 1 LED 12 Æ 250 Vac and dc less than 1.5 mA draw
GLG 1 LED plug-in 12 Æ 250 Vac and dc less than 1.5 mA draw
GLH 2 LED 18 Æ 30 Vdc 7 mA typ. current draw
Figure 16. Wiring Diagram 1 In Figure 18, Wiring Diagram 3, regardless of the position of the
basic switch, the current for the LED can flow through the LED
and the LED will illuminate indicating power available.
Note:
While every effort is made to ensure that the above guidelines are
accurate, no responsibility can be accepted for failure to apply good engineering
practice to machinery design and use of Honeywell products. Never apply any of
the procedures outlined above on live circuits. Ensure that testing of changes is
carried out with no risk of injury during tests. These guidelines are produced to help
our customers make the right choices in applying our Limit Switches to general
applications. Contact your local Honeywell representative if you have any difficulties.
GLZ51C Nylon 25,4 [1.00] 12,7 [0.50] 04; 1NC/1NO, slow action
GLZ304 GLZ304 GLZ304
MBB
GLZ51E Bronze 19,0 [0.75] 6,35 [0.25]
06; 2NC, Slow action GLZ306 GLZ306 GLZ306
GLZ51T SST 19,0 [0.75] 9,5 [0.38]
07; 1NC/1NO, snap action,
GLZ51Y Rubber 50,0 [1.97] 10,0 [0.39] GLZ307 GLZ307 GLZ307
gold contacts
Adjustable length lever; 38,1 to 89,0 mm [1.5 to 3.5 in] radius 20; 2NC/2NO, snap action GLZ320 – –
GLZ52A Nylon 19,0 [0.75] 6,35 [0.25] 21; 2NC/2NO, snap action,
GLZ321 – –
GLZ52B Steel 19,0 [0.75] 6,35 [0.25] sequence
22; 2NC/2NO, snap action,
GLZ52D Nylon 38,1 [1.50] 6,35 [0.25] GLZ322 – –
gold contacts
GLZ52E Nylon 19,0 [0.75] 33,1 [1.30] 24; 2NC/2NO, snap action, use
– GLZ324 GLZ324
with LED body
GLZ52W Rubber 40.7 [1.60] 12,7 [0.50]
26; 2NC/2NO, snap action,
GLZ52Y Rubber 50,0 [1.97] 10,0 [0.39] GLZ326 – –
center neutral
Fixed length yoke lever; 38,1 mm [1.5in] radius 32; 2NC/2NO, snap action,
GLZ53 No rollers n/a n/a gold-plated contacts, use with – GLZ332 GLZ332
LED body
GLZ53A Nylon 19,0 [0.75] 6,35 [0.25]
33; 1NC/1NO, slow action
GLZ53B Steel 19,0 [0.75] 6,35 [0.25] GLZ333 GLZ333 GLZ333
BBM, gold-plated contacts
GLZ53E Bronze 19,0 [0.75] 6,35 [0.25]
34; 1NC/1NO, slow action,
GLZ334 GLZ334 GLZ334
Adjustable rod levers MBB, gold plated contacts
36; 2NC, slow action, gold-
GLZ336 GLZ336 GLZ336
GLZ54 Hub only n/a n/a plated contacts
Alum. rod
3,17 mm
GLZ54J 200 mm n/a
[0.125 in]
[7.9 in]
Alum. rod
3,17 mm
GLZ54K 140 mm n/a
[0.125 in]
[5.51 in]
SST rod
3,17 mm
GLZ54N 318 mm n/a
[0.125 in]
[12.5 in]
Fixed length offset lever; 38,1 mm [1.5 in] radius
Delrin rod,
GLZ68 305 mm 6,35 [0.25] n/a
[12.0 in]
22 sensing.honeywell.com
MICRO SWITCH™ Global Limit Switches, GLA Series
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgement
or consult your local sales office for specific warranty details. If
warranted goods are returned to Honeywell during the period of
coverage, Honeywell will repair or replace, at its option, without
charge those items it finds defective. The foregoing is buyer’s
sole remedy and is in lieu of all other warranties, expressed
or implied, including those of merchantability and fitness for
Find out more a particular purpose. In no event shall Honeywell be liable for
Honeywell serves its customers consequential, special, or indirect damages.
through a worldwide network While we provide application assistance personally, through our
of sales offices, representatives literature and the Honeywell web site, it is up to the customer to
and distributors. For application determine the suitability of the product in the application.
assistance, current specifica-
Specifications may change without notice. The information we
tions, pricing or name of the
supply is believed to be accurate and reliable as of this printing.
nearest Authorized Distributor,
However, we assume no responsibility for its use.
contact your local sales office.
To learn more about Honeywell’s
sensing and switching products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com