You are on page 1of 3

950G Wheel Loader 4BS00001-UP (MACHINE) POWERED BY 3126 Eng...

18/03/2010 10:45:45

Cerrar SIS

Pantalla anterior

Producto: WHEEL LOADER


Modelo: 950G WHEEL LOADER 4BS
Configuración: 950G Wheel Loader 4BS00001-UP (MACHINE) POWERED BY
3126 Engine

Localización y Solución de Problemas


Payload Control System
Número de medio -SENR6614-17 Fecha de publicación -01/03/2007 Fecha de actualización -08/03/2007

i02480758

Diagnostic Code List


SMCS - 7494; 7569

Note: The Payload Control System (PCS) can be diagnosed with the Caterpillar Electronic Technician
(ET). This ability starts with software version 2.07. In order to be consistent with ET CID-FMI codes,
some of the diagnostic codes of the PCS have been changed.

If the Electronic Control Module ECM detects a diagnostic code, the "SERV CODE" symbol will be
shown.

The diagnostic codes are shown in the following chart.

Table 1

Diagnostic Codes for Version 2.06 and Earlier


CID No. / FMI No. Description
CID 0168 Electrical System Voltage
FMI 00 Data valid but above normal operational range
FMI 01 Data valid but below normal operational range
CID 0254 Electronic Control Module
FMI 13 ECM calibration required
CID 0350 Position Sensor (Lift Linkage)
FMI 01 Data valid but below normal operational range
FMI 02 Data erratic, intermittent, or incorrect
CID 0364 Pressure Sensor (Lift Cylinder Head End)
FMI 01 Data valid but below normal operational range
FMI 02 Data erratic, intermittent, or incorrect
CID 0769 Pressure Sensor (Lift Cylinder Rod End)

VCADS Pro 1(3)


950G Wheel Loader 4BS00001-UP (MACHINE) POWERED BY 3126 Eng... 18/03/2010 10:45:45

FMI 01 Data valid but below normal operational range


FMI 02 Data erratic, intermittent, or incorrect
CID 0817 ECM Internal Backup Battery
FMI 04 Voltage below normal or shorted low
FMI 08 Abnormal frequency, pulse width, or period
CID 0820 Keypad Data Link
FMI 02 Data erratic, intermittent, or incorrect

Table 2

Diagnostic Codes for Version 2.07 and Later


CID No. / FMI No. Description
CID 0168 Electrical System Voltage
FMI 00 Data valid but above normal operational range
FMI 01 Data valid but below normal operational range
CID 0254 Electronic Control Module
FMI 12 Internal clock not functioning properly
FMI 13 ECM calibration required
CID 0350 Position Sensor (Lift Linkage)
FMI 02 Data erratic, intermittent, or incorrect
FMI 13 Out of calibration
CID 0364 Pressure Sensor (Lift Cylinder Head End)
FMI 02 Data erratic, intermittent, or incorrect
FMI 08 Abnormal frequency, pulse width, or period
CID 0769 Pressure Sensor (Lift Cylinder Rod End)
FMI 02 Data erratic, intermittent, or incorrect
FMI 08 Abnormal frequency, pulse width, or period
CID 0817 ECM Internal Backup Battery
FMI 12 Bad device or component
CID 0820 Keypad Data Link
FMI 02 Data erratic, intermittent, or incorrect

VCADS Pro 2(3)