You are on page 1of 3
Qatargas Helium (1) Project Main Construction Work ; sre BD | Feu oe i, PROCEDURE QUALIFICATION RECORD (POR) AWSD/1.1 SECTION 4 PART B EDITION 2008 & 230/40/O/QA/PCINA/O116) RUNS STRUCTURAL STEEL ME, “GMAWISPRAY ARC). jOINT DESIGN USED: B-Uza-GF 7 Filet: Double Weld Vertical Progression: Up F] ~~ Down oe Yes No Backing Material: CS -S 275uR(Size 75x10 mm) ELECTRICAL CHARACTERISTICS Root Face Dimension: NIA Curent: ACC] DCEP BIDCEN CPulsed 3 ‘SHIELDING Fix NIA B88. rate Composition Flow Rate... Gas Cup Size. TECHNIQUE ‘Stringer or Weave Bead: Both (Weave max. 12mm) ‘Mult-pass or Single Pass (per side) Number of Electrodes: Electrode Spacing: Peening: Interpass Cleaning: Brushi POSTWELD HEAT TREATMENT Tomo. NA Time NAA ¢705-6 ‘Cap-3 | “GMAW _[ER70S-6 Remarks: Welder PHAM QUOC DAI (W-58) a) [_ FRUNS Pr [eaonie Youugnese| 3.01 Seo ee. ieay ae ' we Qatargas Helium (ll) Project Main Construction Work PROCEDURE QUALIFICATION RECORD (POR) AWSD1.4 SECTION 4 PART B EDITION to IN 2008 & 230/10/10/AIPCINAIO116) i ts ]catarges Hetum n Project T ealtaw CBC orcs sald =~ ‘ercmneennc uc Main Construction Work {Wer = | | ru Procedure Qualification Record (POR) # PQR-FRI-O01 (16) page: 3of 3 Test Results s ‘TENSILE TEST, ‘Specimen | Width | Thickness | Area(mm2)] Ultimate | Minimum’ Ultimate Unit |” Character of No TensileLoad, | UTS value | stress, psi | Fallreand fe tb MPa Location bor 1997 | agai | 36765) i560 400 as PARENT dl MATERIAL 02 1996 | a8 | 37.48) 15730 “400 “423 PARENT a MATERIAL GUIDED BEND TEST Specimen | Type of Bend Result Remarks ] No ‘003, SIDE BEND ‘ACCEPT NO DEFECT OBSERVED 7 004 SIDE BEND ‘ACCEPT 7 ‘NO DEFECT OBSERVED 005: SIDE BEND ‘ACCEPT E NO DEFECT OBSERVED 006 SIDE BEND. ‘ACCEPT NO DEFECT OBSERVED VISUAL INSPECTION ‘Appearance: Acceptable Undercut: Acceptable Piping Porosity: Mone uA Convexity:None ‘Test Date : 11-Dec-2034 pass Other Tests: MPI Report No.:PQR-FRI-OOL Welder’s name: PHAM QUOC DAI__ ‘Test conducted by: EXOVA Qatar LLC Testing Laboratory Report No: 104974 ‘We, the undersigned, certify that the statements in this prepared, welded and tested in conformance with the Structural Welding Code ~ Steel. Radiographic — ultrasonic Examination RT Report No.: PQR:FR-OO1 Result: PASSED. UT Report No: N/A Result: ~ FILLET WELD TEST RESULTS Minimum size multiple pass Maximum size single ‘Macroetch Macroetch 2 NA 3._W/A__ 4, 2A 2. N/A, 3A All-weld-metal tension test Tensile strength, psi:N/A Wield point / strength, psi_W/A____ Elongation tn 2 in, %__N/A Laboratory Test no, NIA, is record are correct and that the test welds were ‘of AWS D.1/D1.1M, (2008) requirements of Claust Fries Tet MEDGULF NAME fi : —__| wD: Muti _| $-al-Jecote |M-snuaegan | SIGNATURE ye ceric : yates pare sh ee 24,

You might also like