Project Typical Police Post KEOH

Client MPTF Made by Date Page


Location GUTTER SLAB GS1 from A to A' ARNOLD T 27-Nov-17
ONE-WAY SOLID RC SLAB DESIGN to BS 8110:2005 c/w ANALYSIS Checked Revision Job No
Originated from RCC31.xls v4.0 on CD © 2006 TCC PHILP M DSU-2017-009

LOCATION Supports from grid A to grid A'

MATERIALS COVERS
fcu 25 N/mm² h agg 20 mm Top cover 25 mm
fy 460 N/mm² s 1.05 steel Btm cover 25 mm
fyv 460 N/mm² c 1.50 concrete
steel class A
SPANS L (m) H (mm) SUPPORTS
SPAN 1 0.400 150 Support No Type
SPAN 2 1 C
SPAN 3 LOADING PATTERN 2 E
SPAN 4 min max K(nife), C(antilever) or E(ncastre)
SPAN 5 DEAD 1 1.4
SPAN 6 IMPOSED 1.6

LOADING UDLs (kN/m²) PLs (kN/m) Position (m) LOADING


Dead Imposed Position Dead Imposed Position
Span 1 Load Load from left Span 4 Load Load from left
UDL 5.43 2.00 ~~~~ UDL ~~~~
PL 1 5.03 0.100 PL 1
PL 2 PL 2
Span 2 Span 5
UDL ~~~~ UDL ~~~~
PL 1 PL 1
PL 2 PL 2
Span 3 Span 6
UDL UDL ~~~~
PL 1 PL 1
PL 2 PL 2

LOADING DIAGRAM

A A'
REACTIONS (kN/m)
SUPPORT 1 2
Characteristic Dead 7.20
Max Imposed 0.80
Min Imposed
MAX ULTIMATE 0.74 10.62