FVR-C9S ADJUSTABLE FREQUENCY DRIVE
2
Description FVR NNN C9S N XX ␣␣␣␣␣␣
Hp
F12 = 1/8 Hp
001 = 1 Hp
Phase Selection
7 = Single Phase
2 = Three Phase
Product Revision
2-2 Data subject to change without notice 9/98. © 1998 General Electric Company
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
Standard Specifications
Environmental Conditions
Installation location: Indoors at an altitude of 3300 ft. (1,000m) or less. Free of dust, corrosive gases, oil
mist and direct sunlight.
2
Ambient temperature: -10 to +50°C
Ambient humidity: 20 to 90% RH (non-condensing)
Vibration: 5.9 m/s2 (0.6G) or less
Storage temperature: -25 to +65°C
Cooling method: 0.12 to 1 Hp - Convection
2 Hp and greater - forced air (integral fan)
Input Frequency
Power setting: 220-240 VAC, single phase, 50-60 Hz +10% to -10% V
200-230 VAC, three phase, 50-60 Hz +10% to -15% V
Output Frequency
Setting: Maximum frequency: 50 to 120 Hz (in 1 Hz steps)
Base frequency: 50 to 120 Hz (in 1 Hz steps)
Starting frequency: 1 to 6 Hz (in 1 Hz steps)
Accuracy (Stability): Digital setting: ±0.01% of maximum frequency (at -10 to +50°C)
Analog setting: ±1.0% of maximum frequency (at 25± 10°C)
Setting resolution: Digital setting: 0.1 Hz (99.9 Hz or less), 1 Hz (100 to 120 Hz)
Analog setting: 1/255 of maximum frequency
(i.e. 0.25 Hz / 60 Hz; 0.5 Hz / 120 Hz)
Control
Control method: Sinusoidal PWM control (low noise using high frequency carrier)
Operation method: Keypad operation: RUN or STOP key
Input signal: Forward/Reverse command,
Coast-to-coast command. Trip command (external alarm) Alarm reset
Frequency setting: Keypad operation: INC (UP) or DEC (DOWN) keys
Potentiometer: 1 to 5 k ohm
Analog input: 0 to 5 VDC, 0 to 10 VDC
(Resistance =12 k ohm), 4 to 20 mA DC (Single phase only.
Consult factory for 3 phase)
Multistep frequency: Up to 4 different frequencies can be selected using terminal
BX and THR
Indication: Running: Digital indication of output frequency or output current (3-digit LED)
Tripped: Cause of trip by code (3-digit LED). Illuminated LED under any condition
indicates capacitor is charged.
Acceleration/deceleration time: 0 to 60 sec. (independently adjustable acceleration and deceleration)
Voltage/frequency Setting of maximum frequency / base frequency is variable.
(V/F) characteristic:
Data subject to change without notice 9/98. © 1998 General Electric Company
2-3
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
Restart after momentary The drive restarts without causing the motor to stop if the automatic restart is
power failure: specified for the drive.
2 Frequency limiter: High and low limits can be set for the output frequency.
Bias frequency: The bias frequency can be set to an analog reference frequency.
Frequency jump control: Jump frequency (3 points) and jump hysteresis width (1 point) can be set
Torque boost: 32-step selectable
Starting torque: 150% for 60 seconds
Protection
Overload: Detects overcurrent to stop drive
Momentary overcurrent: Protects drive in case of ground fault (when starting),
and short circuit of output circuit.
Overvoltage: Detects DC link circuit overvoltage to stop drive
Overheating: Detects abnormal temperature of cooling fin to stop drive
Motor protection: Electronic thermal overload relay
Alarm output: Outputs a relay contact signal when any protective function is activated (SPDT
contact, 250 VAC, 0.3 A, cos = 0.3)
Options
Standard: DIN-Rail mounting kit, EMI filter (single phase ratings) and Parameter copy unit
Mounting Space
3.94”
(10cm)
PRG
RUN
RESET
FUNC STOP
DATA
FVR-C9S
0.394” 0.394”
(1cm) (1cm)
CLOSED OPEN
3.94”
(10cm)
2-4 Data subject to change without notice 9/98. © 1998 General Electric Company
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
Dimensions
2
0.24 (6.2) D
D2
3.15 (80)
0.39 (10)
0.06 (1.5)
0.20 (5)
0.06 (1.5) 2 - 0.20 X 0.24
(2 - 5 X 6.2)
0.24 (6.2)
1.97 (50)
4.33 (110)
3.94 (100)
4.72 (120)
2.76 (70)
0.20 (5)
0.39 (10)
0.06 (1.5) D1
D2
4.33 (110)
0.24 (6.2)
0.24 (6)
2 - dia. 0.20
(2 - dia. 5)
0.24 (6.2)
1.97 (50)
5.12 (130)
4.65 (118)
4.21 (107)
3.15 (80)
0.24 (6.2)
TERMINAL M3.5
0.45 (11.5)
D1
0.20 (5) 0.43 (11)
DWG 2: FVR002C9S-7UX
Data subject to change without notice 9/98. © 1998 General Electric Company
2-5
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
D2
3.15 (80)
2 0.26 (6.5)
2.64 (67)
0.26 (6.5)
0.39 (10)
0.06 (1.5)
0.20 (5)
.06 (1.5) 2 - 0.20 X 0.24
(2 - 5 X 6.2)
0.24 (6.2)
1.97 (50)
4.33 (110)
3.94 (100)
4.72 (120)
2.76 (70)
0.20 (5)
0.39 (10)
0.43 (11) TERMINAL M3.5
0.06 (1.5) D1
0.24 (6.2) D
D2
4.33 (110)
0.24 (6)
0.24 (6)
2-=0 20
(2-/5)
0.24 (.5)
1.97 (50)
5.12 (130)
4.65 (118)
4.21 (107)
3.15 (80)
TERMINAL M3.5
0.24 (5)
0.45 (11.5)
D1
0.20 (5) 0.43 (11)
DWG 2: FVR002C9S-2UX
Rated Current External Dimensions: inches (mm) DWG No.
Model No. [A] D D1 D2
FVRF12C9S-2UX 0.7 2.38 (60.5) 0.89 (22.5) 0.39 (10)
FVRF25C9S-2UX 1.4 2.58 (65.5) 1.08 (27.5) 0.59 (15) DWG 1
FVRF50C9S-2UX 2.5 2.97 (75.5) 1.48 (37.5) 0.98 (25)
FVR001C9S-2UX 4.0 3.96 (100.5) 2.46 (62.5) 1.97 (50)
FVR002C9S-2UX 7.0 5.14 (130.5) 3.05 (77.5) 2.56 (65) DWG 2
FVR003C9S-2UX 10.0 5.53 (140.5) 3.05 (77.5) 2.56 (65)
2-'005
2-6 Data subject to change without notice 9/98. © 1998 General Electric Company
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
Dimensions
0.24 (6.2)
2.58 (65.5)
5.45 (138.5)
2.87 (73)
2
5.51 (140)
0.45 (11.5)
0.71 (18)
0.24 (6.2)
2 - dia. 0.20 0.24 (6.2)
(2 - dia. 5)
0.24 (6.2)
2.01 (51)
7.09 (180)
5.61 (168)
5.18 (157)
5.08 (129)
0.24 (6.2)
0.45 (11.5)
TERMINAL M4 3.37 (85.5)
FVR005C9S-2UX
Data subject to change without notice 9/98. © 1998 General Electric Company
2-7
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
FAB
Power Supply L1 U
AC200 - 230V
50/60 Hz L2 888 V IM
3-phase
L3 W
CN2
13
12
11
E (G)
FWD
REV
RST
BX
CM
THR
FM
10V 1mA
2-8 Data subject to change without notice 9/98. © 1998 General Electric Company
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
FVRF12C9S-7UX to FVR002C9S-7UX
2
FAB
Power Supply L1 U
AC220 - 240V
50/60 Hz 888 V IM
1-phase L2 W
C1 CN2
13
12
11
E (G)
FWD
REV
RST
BX
CM
THR
FM
10V 1mA
Data subject to change without notice 9/98. © 1998 General Electric Company
2-9
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
Power supply L1 U
AC200~230V 8 8 8
50/60Hz L2 V IM
3 Phase
L3 W
CN2
13
Volume for 12 x
frequency setting
11
E (G)
2-10 Data subject to change without notice 9/98. © 1998 General Electric Company
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
FVRF12C9S-7UX to FVR002C9S-7UX
2
FAB Thermal Relay
Power supply L1 U
AC220-240V 8 8 8
50/60Hz V IM
1 Phase
L2 W
E (G) PE
* PE terminal blocks for the drive and motor should be provided in the cabinet in which the drive is installed.
Data subject to change without notice 9/98. © 1998 General Electric Company
2-11
FVR-C9S ADJUSTABLE FREQUENCY DRIVE
Options
2-12 Data subject to change without notice 9/98. © 1998 General Electric Company