You are on page 1of 37

MCAC-2012-06

Full DC Inverter Mini VRF

2012

Commercial Air Conditioner Business Units


Midea Air Conditioning and Refrigeration Sector
Add: West region of Midea commercial air conditioner department, Industry Avenue,
Beijiao, Shunde, Foshan, Guangdong, P.R. China Postal code:528311
Tel:+86-757-22394101 Fax: +86-757-26338003
http://www.midea.com http://www.mideaaircon.com
Corporate Midea CAC (MCAC)

Introduction As a key part of Midea Group, the Midea Central Air Conditioner
(CAC) Business Unit is a professional CAC products supplier and
commercial products solution expert. Since 1999 Midea central
air-conditioner contributes to the commercial product R&D and
technology innovation. By cooperating with the international
enterprises plus the independent R&D, Midea CAC achieves big
success in the commercial air-conditioner market and has
Midea Group established thousands of sample projects all over the world.

From its humble beginnings in 1968, Midea has developed into a Right now Midea CAC is one of the most professional CAC products
large corporation, covering HVAC, appliances, lighting, industrial supplier as well as the professional project solution provider in
components, logistics, and real estate. Its 40 years of relentless marketing, sales, project design and after service etc.
growth has brought its global turnover to $14 billion USD in 2009.
Consequently, Midea has created over 150,000 jobs both within MCAC Chongqing factory with 9 product lines concentrates on the
China and all over the world. In addition to providing affordable water cooled centrifugal / screw/ scroll chillers, Air cooled screw/
goods to consumers worldwide, Midea is a responsible corporate scroll chiller and AHU/FCU products.
citizen, and has contributed to several social causes. MCAC Shunde factory with 31 product lines concentrates on the
VRF (DC inverter product/ Digital scroll product), split product, heat
Midea believes in creating value through rapid response to pump water heater, AHU/FCU etc.
market demands, cost-efficient operations and consumer
satisfaction. As a result, Midea wields vast production capacities
to meet these demands, a fully integrated manufacturing
process, and a comprehensive range of affordable, high-quality
products to serve its global customers.

Today, Midea is a home appliance leader in China. The company


continues to actively globalize its operation by opening plants in
Vietnam, Belarus and Egypt. Additionally, Midea has several
forthcoming plants in order to offer enhanced products and
services closer to the market.
3 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 4

Contents Midea R410A


Full DC inverter Mini VRF
Midea Full DC inverter system is a highly efficient solution for small commercial
buildings that requiring heating and cooling system up to 8 zones in one outdoor
Nomenclature:
unit. Midea offers more than 100 models in about 15 types indoor units can be
combined with mini inverter outdoor unit which provides individual comfort Outdoor unit
space, easy installation and control. This is a flexible system that bridges the
MDV - V 120 W / D R N1
capacity gap between VRF and Multi systems – ideal for commercial and private
applications. Refrigerant type
N1: R410A
Power Supply
--: 220~240V, 50Hz, 1Ph
R: 380~415V, 50Hz, 3ph
04 Nomenclature V: 208~230V, 60Hz, 1ph
D: 208~230V, 60Hz, 3ph
C: 380~415V, 60Hz, 3ph
05 Main Technologies Inverter Type
D: DC Inverter

08 Main Features W: Outdoor unit

Cooling Capacity (×100W)

15 Indoor Unit Lineup Inverter System


Multi - Digital - Variable

56 Outdoor Unit Lineup


Indoor unit
58 Control Systems
MDV - D 28 Z / D D N1
69 HRV
72 Accessories Refrigerant type
N1: R410A Omit For R22
Electrial Auxiliary Heater
D: with EAH Omit For without EAH

Motor Type
D: DC Fan Motor Omit For AC Fan Motor

Indoor Unit Structral category


Q4: Standard four way cassette
Q4-A: Compact four way cassette
Q2: Two way cassette
T1: High Static Pressure Duct
T2: A5 Unit
T3: Low Pressure Static Pressure Duct
DL: Ceiling & Floor
G: Wall mounted
Z: Floor Standing

Cooling Capacity (X 100W)

VRF Indoor Unit

Multi - Digital - Variable


Full DC Inverter Mini VRF 6

Main Technologies
Never ending development of Midea’s technologies will satisfy you’re your expectations. Each of this year’s
new technologies were considered to provide you the most efficient and convenient air conditioners.

High efficiency full DC inverter compressor

Main Technologies
High efficiency and Energy-saving, thanks to the DC inverter compressor and DC fan motor. Inverter
systems save energy as continuous operation offers the same capacity with lower power consumption.
This benefits all occupants by maintaining even room temperatures, as well as the environment by reduc-
ing energy consumption.

Highly Efficient DC Motor:


- Creative motor core design
- High density neodymium magnet
- Concentrated type stator
-Wider operating frequency range
Better balance and Extremely Low Vibration:
- Twin eccentric cams
- 2 balance weights
Highly Stable Moving Parts:
- Optimal material matching rollers and vanes
-Optimize compressor drive technology
Compressor - Highly robust bearings
(Twin Rotary) structure
-Compact structure

Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume.

Compressor efficiency New DC motor-centralized winding

Efficiency-Rotor Speed Curve


Common DC motor-distributing winding

Centralizing winding

Rotor speed(s-1)
20 40 60 80 100
Distributing winding

Low noise full DC fan motor


DC fan motor structure DC motor efficiency
(comparison with a conventional AC motor)
Panasonic DC fan motor : 100

-Wider fan speed adjustment 80

EFFICIENCY (%)
DC motor Approx.
-lower noise 60
20%
increase
-lower power consumption 40
Approx. AC motor
40%
20
increase
0
200 300 400 500 600 700 800 900 1000
MOTOR SPEED (RPM)
7 Full DC Inverter Mini VRF

High performance heat exchanger

Hydrophilic Blue Fin Coil


The coils are special blue coated to enhance its durability. These special
coated layers serve as protection against corrosion from air, water and
other corrosive agents. Blue fin coil has 3 times higher resistance against
corrosion. This special coating assures longer coil live for years of reliable
Main Features
comfort.

Improved noise reducing design


Optimally design the fan shape and Noise-reducing designed discharge air grille increase the air volume
and reduce the running noise.

Air deflector

New designed grilling

New designed fan

Newly Designed Fan Guard Powerful Large Propeller

Application flexibility-various Indoor units


Midea Mini VRF with intelligence control that gives you independent zoning control with maximum flexibility.
The Advantage of Midea Mini VRF is that a single outdoor unit supports up to 7 indoor units. Use your
backyard more wisely with much more space available created by less number of outdoor units.

Max. 6 indoor units for a 12kW outdoor unit installation


Max. 6 indoor units for a 14kW outdoor unit installation
Max. 7 indoor units for a 16kW outdoor unit installation
9 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 10

Main Features Wide operation temperature range


Up to 48°C in cooling mode and down to -15°C in heating mode.
Auto addressing The operation range of the Mini VRF system works to reduce limitations on installation locations. The opera-
tion temperature range for heating goes all the way down to -15°C, while cooling can be performed with
Addressing indoor units are able to be done just by pressing the button of the controller.No need to set the
ou`tdoor temperatures as high as 48°C. Both these achievements are due to the employment of a high pres-
address by the DIP switch one by one.
sure dome-type compressor.
Wired controller and wireless controller can enquiry and modify every indoor units address.

0
EF 1 Previous COOLING MODE
Need To Set The
23
BCD

Address Manually, Design 48°C


-15°C
45

one By One
Improved on
67
24
89A
Mini VRF Automatically HEATING MODE °C
Identify
-15°C 27°C

More convenience in installation -20 -10 0 10 20 30 40 50


Outdoor temp. °C(D.B.)

Offering four direction space for installation to connect pipes and


No matter in extremely cold winter when outdoor temperature gets as low as -15°C or in hot summer
wirings for meet a variety installation request. (for 12, 14, 16 kW
when temperature is up to 48°C, the mini VRF system will keep stable performance.
model)

Front side Right side Back side Bottom side Smooth control
Fat pipe By using all inverter-driven compressors, Midea is able to significantly reduce the electrical and mechanical
Upper side
stresses that are placed on fixed-speed compressors during start-up. Current absorption on an inverter-
driven compressor is smoothed out at start-up thus reducing the wear on the electrical and mechanical com-
ponents and increasing reliability.

To suit the variety of rooms found in small offices and shops, Back side Start-up using all inverter-driven compressor
the Mini VRF system offers wide range of indoor and outdoor units .
Left side
mini VRF indoor and outdoor units are almost as easy to install as Fixed-speed unit: Fixed-speed unit:
Compressor sudden start-up Compressor 5-7 times drive current
residential air conditioning systems , making them ideal for small
drive current
offices and shops . No more than
inverter drive current
Inverter:
gradual start-up
Benefits of using R410A refrigerant
Start > Drive Start > Drive

Comparison of refrigerant Making continuous efforts to stay eco-friendly, midea's air


boiling points (liquid and gas) conditioners use R-410A, an environmentally friendly
Compressor
0
-51.8 -48.5 -26.18 refrigerant to help rid the air of pollutants and restrain the Fixed-speed unit:
Compressor
Before After
oil surface
-10
-20
R32 R125 R134a
use of materials with high global warming potential (GWP). Piping c. 3 times normal drive start-up start-up
-30
High boiling point Incorporating the Energy efficient, non-ozone-depleting stress
Inverter: almost same
-40
Little lowering
-50
-60 Approximately same R410A refrigerant in air conditioning systems delivers as during normal drive
Inverter of oil surface
boiling point
Blend of two
multiple benefits:
Degradation
types with similar R410A unlikely
boiling points Temporary fall
Zero ozone-depleting potential in oil surface due
Blend of three Degradation to sudden outflow
types with R407C likely
Significant increase in energy efficiency. Fixed-speed unit of refrigerant and oil
different Start > Drive
boiling points

Reduced pressure loss for improved performance.


11 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 12

Flexible piping design Space saving design


The Mini VRF provides the max. piping length possibility of 100m, The height difference between outdoor The Mini VRF units are slimmer and more compact, resulting in significant savings in installation
unit and indoor unit can be up to a maximum of 20m. The height difference between indoors unit can be up space.
to a maximum of 8m. These generous allowances facilitate an extensive variety of system designs. In some large residential spaces or some light commercial space, such as villa, restaurant,
usually it need more than one indoor unit, so outside the building are also full of outdoor units.
Now Midea can provide an effective solution-Midea MINI VRF system. Since now the beauty of
the building will be back.

Height differences
between indoor &
outdoor units : 30m* The longest piping
length : 50m
(Equivalent Length)

The first branch joint to the


farthest indoor unit : 20m
Easy installation
Height difference (one-way piping size up : 40m)
between indoor units : 8m
Easy to transport No need special room for the outdoor units. Easy
installation: all the outdoor units can be transported
by elevator. This makes installation dramatically
*when outdoor unit up height difference is 30m,when outdoor unit down height difference is 20m.
easy, and effectively reduces time and labor.
Summary So the Mini VRF system indoor and outdoor units
The longest piping length : 50m (Equivalent Length)
are almost as easy to install as residential air
Total piping length: 100m
conditioning systems, making them ideal for small
From the first branch joint to the farthest indoor unit : 40m (one-way piping size up)
offices and shops.
Autorestart function
Even if there is an extended power failure, the A/C system will automatically restart operation. A power
failure will not cause any settings to be lost, thus eliminating the need for re-programming.
Comfortable temperature
Easy maintenance
The inverter Mini VRF can quickly reach Non Inverter
Forced cooling button makes outdoor unit run in the desired temperature. After reaching High Temperature Fluctuation

cooling mode at any condition, so it is very easy for the set temperature, it finely adjusts to Uncomfortable 25 C
you to charge refrigerant to the system when it need (Energy Loss)
cope with any changes. This means less
to be done.
temperature fluctuation and assures you Comfortable 24 C
The self-diagnosis function detects malfunctions in greater comfort that can be achieved in
major locations in the system and displays the type minutes. Uncomfortable
of malfunction and location. This allows service and (Energy Loss) 23 C
S-Inverter
maintenance to be performed more efficiently. Steady Temperature Fluctuation
13 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 14

More convenient piping connector - branch box


Selection software
Easier and safer installation thanks to a branch box that simplifies piping work and the adoption of screw
connection. Midea has developed a new program to design Mini
VRF systems which meets the consultants’ and
Both left and right pipe flare connectin from outdoor unit to branch box is reserved, simplified the field
installation. distributors’ requirements. The software provides a
quick and convenient selection for users, which
Two sets of pipe size converter are packed with branch box to transfer the pipe size from Φ6.35 to Φ
9.53 and fromΦ12.7 to 15.9. supports multi-languages. Greatly improving the
selection efficiency and simplifying the procedure.

Low noise
The branch pipe is linear expansion design which regu-
lates the flow of refrigerant and reduces the noise. By
locating the branch box in the ceiling or outside ,noise
generated by the branch box can be kept clear of living
spaces, thus maintaining the noise level to a minimum. Load calculation
Project It provides two calculation methods. Directly decide
Brazing-free quick installation the room load or input the detailed parameters such
It contains project information such as project name,
All the piping leading to and from the branch box is connected using screw joints ,which are easy as room area, estimated cooling/heating load index,
nation, location, etc. Detailed meteorologic datas
to use and enable piping installation to be completed quickly. heating capacity and cooling capacity.
make the machines selected fit for the local
environment well.
Indoor installation Piping drawing
The branch box can be installed in the ceiling rather than outside. Furthermore , servicing can A/C selection
be complete easily through access to inner components such as the circuit board by simply Piping drawing shows the detailed layout of an A/C
removing the side and bottom covers. There are 15 types and 100 models of indoor units system and parameters of piping and branch
and all kinds of different power of outdoor units for distributors.
choosing.
Universal indoor units
The same indoor units as R410a DC inverter mini VRF system. Controller selection Report output
To select the right central controller for indoor units Output a total report of selection project in word or
and outdoor units; wireless or remote controller for PDF format.
New piping connection design indoor units.
15 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 16

Indoor Units

Indoor Units Lineup


One-cay Cassette
Two-cay Cassette
Compact Four-way Fassette
Four-way Fassette
Low Static Pressure Duct
Concealed Duct Unit(A5 Type)
High Static Pressure Duct
Ceiling & Floor
Wall-mounted S Type
Wall-mounted C Type
Floor Standing
Console
Fresh Air-processing Unit
17 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 18

INDOOR UNIT LINEUP


One-way Cassette Two-way Cassette High Static Pressure Duct Ceiling & Floor

MDV-D XX DL/N1-C
Model 36 45 56 71

Capacity 3.6kW 4.5kW 5.6 kW 7.1kW


MDV-D XX Q1/N1-C MDV-D XX Q2/N1 MDV-D XX T1/N1-B
Model 28 36 45 56 71 Model 22 28 36 45 56 71 Model 71 80 90 112 140 160 Model 80 90 112 140

Capacity 2.8kW 3.6kW 4.5kW 5.6 kW 7.1 kW Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6 kW 7.1kW Capacity 7.1kW 8.0 kW 9.0 kW 11.2 kW 14.0 kW 16.0 kW Capacity 8.0 kW 9.0 kW 11.2 kW 14.0 kW

Compact Four-way Cassette Four-way Cassette Wall-mounted Type Floor Standing

MDV-D XX Z/N1-F1(F2)B MDV-D XX Z/N1-F4(F5) MDV-D XX Z/N1-F3B


MDV-D XX Q4/N1-D
Model 28 36 45 56 71 Model 22 28 36 45
MDV-D XX G/N1-S MDV-D XX G/N1YB
Capacity 2.8kW 3.6kW 4.5kW 5.6 kW 7.1 kW Capacity 2.2kW 2.8kW 3.6kW 4.5kW
MDV-D XX Q4/N1-A3 MDV-D XX G/DN1-S MDV-D XX G/DN1YB
Model 22 28 36 45 Model 80 90 100 112 140 Model 22 28 36 45 56 Model 56 71 80

Capacity 2.2kW 2.8kW 3.6kW 4.5kW Capacity 8.0 kW 9.0 kW 10.0 kW 11.2 kW 14.0 kW Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6 kW Capacity 5.6 kW 7.1kW 8.0 kW

Low Static Pressure Duct Concealed Duct Unit (A5 Type) Console Fresh Air Processing Unit

MDV-D XX T2/N1-BA5
Model 22 28 36 45 56

Capacity 2.2kW 2.8kW 3.6kW 4.5kW 5.6 kW


MDV-D XX T3/N1-B MDV-D XX Z/DN1-B MDV-D XX T1/N1-FA
Model 18 22 28 36 45 56 Model 71 80 90 112 140 Model 22 28 36 45 Model 125 140

Capacity 1.8kW 2.2kW 2.8kW 3.6kW 4.5kW 5.6 kW Capacity 7.1kW 8.0 kW 9.0 kW 11.2 kW 14.0 kW Capacity 2.2kW 2.8kW 3.6kW 4.5kW Capacity 12.5kW 14kW
19 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 20

One Way Cassette


Specifications

Model MDV-D28Q1/N1-C MDV-D36Q1/N1-C MDV-D45Q1/N1-C MDV-D56Q1/N1-C MDV-D71Q1/N1-C

Power supply 1-phase, 220-240V, 50Hz

kW 2.8 3.6 4.5 5.6 7.1

Cooling capacity kcal/h 2,400 3,100 3,800 4,800 6,100

Btu/h 9,500 12,200 15,300 19,100 24,200

kW 3.2 4.0 5.0 6.3 8.0

kcal/h 2,700 3,400 4,300 5,400 6,800


Heating capacity

Btu/h 10,900 13,600 17,000 21,500 27,300

Thickness 198mm only Cooling 53 53 86 86 86


Power input W
Compact design, ultra slim body with a min. thickness of Heating 53 53 86 86 86

198mm only, especially suitable for narrow ceiling places, Cooling 0.4 0.4 0.4 0.4 0.5
such as lobby, small-size meeting room, etc. Rated current A
Heating 0.4 0.4 0.4 0.4 0.5

m3/h 500/450/410 500/450/410 890/800/750 919/850/760 1,080/980/900


Airflow rate(H/M/L)
Auto swing mechanism guarantees even CFM 294/265/241 294/265/241 524/470/441 541/500/412 636/577/530
198mm
UItra Thin distribution of airflow and better balance Sound level 36/34/30 36/34/30 41/38/35 41/38/35 41/38/35
dB(A)
of room temperature.
Type R410A
Standard built-in drain pump with 750mm pumphead and slim Sing-flow dasign suits Refrigerant
Control method EXV
body makes the installation free from limitation of story height. corner installation
Net dim.(WxHxD) 850×235×400 850×235×400 1,200×198×655 1,200×198×655 1,200×198×655
mm

Body Gross dim.(WxHxD) 1,080×320×460 1,080×320×460 1,380×265×775 1,380×265×775 1,380×265×775


750mm
Net/gross kg 23/27 23/27 31/38 31/38 31/38

Net dim.(WxHxD) 1,050×18×470 1,050×18x470 1,420×10×755 1,420×10×755 1,420×10×755


mm
Panel Gross dim.(WxHxD) 1,100×40×520 1,100×40×520 1,470×50×805 1,470×50×805 1,470×50×805
Fresh air, improved air quality
Net/gross kg 4/6 4/6 9/11 9/11 9/11

Reserved fresh air intake port for high quality Special enzyme sterilization and filtering technology L(flare) mm Ф6.35 Ф6.35 Ф6.35 Ф9.52 Ф9.52
air supply requirement, create a comfort and can filter the bacteria, smog, pollen, etc. Provide
Piping
healthy environment. plenty clean, healthy and natural air supply. G(flare) mm Ф12.7 Ф12.7 Ф12.7 Ф15.9 Ф15.9
connections
Drain piping mm ODФ16 ODФ16 ODФ16 ODФ16 ODФ16

Drain pump pumphead mm 750 750 750 750 750

Standard Controller - Wireless remote controller (RM05/BG(T)E-A/E)

Acetaldehyde Notes:
1. Nominal Cooling Capacities Are Based On The Following Conditions: Return Air Temp. : 27°cdb,19°cwb,outdoor Temp.:35°cdb, Equivalent Ref. Piping: 8m(Horizontal)
2. Nominal Heating Capacities Are Based On The Following Conditions: Return Air Temp.: 20°cdb,outdoor Temp.: 7°cdb, 6°cwb,equivalent Ref. Piping: 8m(Horizontal)
Acetic acid Formol NH3
3. Sound Level Is Measured 1m Below The Unit.
21 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 22

Two Way Cassette


Specifications

Model MDV-D28Q1/N1-C MDV-D36Q1/N1-C MDV-D45Q1/N1-C MDV-D56Q1/N1-C MDV-D71Q1/N1-C

Power supply 1-phase, 220-240V, 60Hz

kW 2.8 3.6 4.5 5.6 7.1

Cooling capacity kcal/h 2,400 3,100 3,900 4,800 6,100

Btu/h 9,600 12,300 15,400 19,100 24,200

kW 3.2 4 5 6.3 8

kcal/h 2,800 3,400 4,300 5,400 6,900


Heating capacity

Btu/h 10,900 13,600 17,100 21,500 27,300

Cooling 53 53 86 86 86
Power input W
Heating 53 53 86 86 86

Cooling 0.4 0.4 0.4 0.4 0.5


Rated current A

Quiet operation High airflow


Heating 0.4 0.4 0.4 0.4 0.5

m3/h 500/450/410 500/450/410 894/800/750 919/850/760 1,080/980/900


Airflow rate(H/M/L) Optimized airflow duct with low resistance makes High airflow for high ceiling application guaran-
CFM 294/265/241 294/265/241 526/471/441 541/500/447 636/577/530
noise level get reduced greatly, min. 24 dB(A). tees equal comfort of large space. It makes
Sound level dB(A) 36/34/30 36/34/30 41/38/35 41/38/35 41/38/35 every comer of the room get even distribution of

Type R410A
Stylish design and slim body airflow and temperature.
Refrigerant
Control method EXV Thanks to the stylish appearance and slim boy, the
33-7/16×9-1/4×15-3/4 33-7/16×9-1/4×15-3/4 47-1/4×7-13/16×25-3/4 47-1/4×7-13/16×25-3/4 47-1/4×7-13/16×25-3/4
unit can be harmonious with the room decoration and
Net dim.(WxHxD) (850×235×400) (850×235×400) (1,200×198×655) (1,200×198×655) (1,200×198×655)
in.(mm) ambient. Slim body with only 300 mm height needs
42-17/32×12-19/32×18- 42-17/32×12-19/32×18- 54-11/32×10-7/16×3017 54-11/32×10-7/16×3017 54-11/32×10-7/16×3017
Body Gross dim.(WxHxD)
1/8 (1,080×320×460) 1/8 (1,080×320×460) /32 (1,380×265×775) /32 (1,380×265×775) /32 (1,380×265×775) small suspended ceiling space. Installation is free of
Net/gross lbs.(kg)
story height limitation which makes the decoration
50.7/59.6(23/27) 50.7/59.6(23/27) 68.3/83.8(31/38) 68.3/83.8(31/38) 68.3/83.8(31/38)
much more flexible.
41-11/32×23/32×18-1/2 41-11/32×23/32×18-1/2 55-29/32×13/32×29-23/ 55-29/32×13/32×29-23/ 55-29/32×13/32×29-23/
Net dim.(WxHxD) (1,050×18×470) (1,050×18×470) 32 (1,420×10×755) 32 (1,420×10×755) 32 (1,420×10×755)
in.(mm)
Panel Gross dim.(WxHxD) 43-5/16×1-9/16×20-1/2( 43-5/16×1-9/16×20-1/2( 57-7/8×1-31/32×31-11/1 57-7/8×1-31/32×31-11/1 57-7/8×1-31/32×31-11/1
1,100×40×520) 1,100×40×520) 6 (1,470×50×805) 6 (1,470×50×805) 6 (1,470×50×805)
Net/gross lbs.(kg) 8.8/13.2(4/6) 8.8/13.2(4/6) 19.9/24.2(9/11) 19.9/24.2(9/11) 19.9/24.2(9/11) 305mm
300mm

L(flare) in.(mm) 1/4 (Φ6.35) 1/4 (Φ6.35) 1/4 (Φ6.35) 3/8(Ф9.52) 3/8(Ф9.52)
Piping
G(flare) in.(mm) 1/2(Φ12.7) Ф5/8(15.9)
connections
1/2(Φ12.7) 1/2(Φ12.7) Ф5/8(15.9) Standard built-in drain pump with 750mm pumphead
Drain piping in.(mm) OD Ф5/8(Ф16) OD Ф5/8(Ф16)
(higher pumphead can be customized).
OD Ф5/8(Ф16) OD Ф5/8(Ф16) OD Ф5/8(Ф16)

Standard Controller - Wireless remote controller (RM05/BG(T)E-A/E)

750mm

Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal)
3. Sound level is measured 3.28ft.(1m) below the unit. Flat-type suction grille design makes maintenance
work very easy.
23 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 24

Specifications Specifications

Model MDV-D22Q2/N1 MDV-D28Q2/N1 MDV-D36Q2/N1 MDV-D45Q2/N1 MDV-D56Q2/N1 MDV-D71Q2/N1 Model MDV-D22Q2/VN1 MDV-D28Q2/VN1 MDV-D36Q2/VN1 MDV-D45Q2/VN1 MDV-D56Q2/VN1 MDV-D71Q2/VN1

Power supply 1-phase, 220-240V, 50Hz Power supply 1-phase, 220-240V, 60Hz

kW 2.2 2.8 3.6 4.5 5.6 7.1 kW 2.2 2.8 3.6 4.5 5.6 7.1

Cooling capacity kcal/h 1,900 2,400 3,100 3,800 4,800 6,100 Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800 6,100

Btu/h 7,500 9,500 12,200 15,300 19,100 24,200 Btu/h 7,500 9,500 12,300 15,400 19,100 24,200

kW 2.6 3.2 4.0 5.0 6.3 8.0 kW 2.6 3.2 4 5 6.3 8

kcal/h 2,200 2,700 3,400 4,300 5,400 6,800 kcal/h 2.2 2,800 3,400 4,300 5,400 6,900
Heating capacity Heating capacity

Btu/h 8,900 10,900 13,600 17,000 21,500 27,300 Btu/h 8,900 10,900 13,600 17,100 21,500 27,300

Cooling 57 57 60 92 108 154 Cooling 57 57 60 92 108 154


Power input W Power input W
Heating 57 57 60 92 108 154 Heating 57 57 60 92 108 154

Cooling 0.35 0.45 0.45 0.55 0.55 0.75 Cooling 0.35 0.45 0.45 0.55 0.55 0.75
Rated current A Rated current A
Heating 0.35 0.45 0.45 0.55 0.55 0.75 Heating 0.35 0.45 0.45 0.55 0.55 0.75

m3/h 654/530/410 654/530/410 725/591/458 850/670/550 980/800/670 1,200/1,000/770 m3/h 674/509/381 674/509/381 740/577/435 878/689/561 941/776/654 1,236/1,110/864
Airflow rate(H/M/L) Airflow rate(H/M/L)
CFM 385/312/241 385/312/241 427/348/270 500/394/324 577/471/394 706/589/453 CFM 397/300/224 397/300/224 436/340/256 517/406/330 554/457/385 727/653/509

Sound level dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34 Sound level dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34

Type R410A Type R410A


Refrigerant Refrigerant Control
Control method EXV EXV
method

1,172×300×592 1,172×300×592 1,172×300×592 1,172×300×592 1,172×300×592 1,172×300×592 46-1/8×11-13/16×23-5/16 46-1/8×11-13/16×23-5/16 46-1/8×11-13/16×23-5/16 46-1/8×11-13/16×23-5/16 46-1/8×11-13/16×23-5/16 46-1/8×11-13/16×23-5/16
Net dim.(WxHxD) Net dim.(WxHxD) (1,172×300×592) (1,172×300×592) (1,172×300×592) (1,172×300×592) (1,172×300×592) (1,172×300×592)
mm in.(mm)
Gross dim.(WxHxD) 1,355×400×675 1,355×400×675 1,355×400×675 1,430×90×680 1,430×90×680 1,430×90×680 Gross dim.(WxHxD) 53-3/8×15-3/4×26-9/16 53-3/8×15-3/4×26-9/16 53-3/8×15-3/4×26-9/16 53-3/8×15-3/4×26-9/16 53-3/8×15-3/4×26-9/16 53-3/8×15-3/4×26-9/16
Body Body (1,355×400×675) (1,355×400×675) (1,355×400×675) (1,355×400×675) (1,355×400×675) (1,355×400×675)

Net/gross kg 34/42.5 34/42.5 34/42.5 36.5/45 36.5/45 36.5/45 Net/gross lbs.(kg) 75/94(34/42.5) 75/94(34/42.5) 75/94(34/42.5) 80.5/99(36.5/45) 80.5/99(36.5/45) 80.5/99(36.5/45)

1,430×90×680 1,430×90×680 1,430×90×680 1,355×400×675 1,355×400×675 1,355×400×675 56-5/16×3-9/16×26-3/4 56-5/16×3-9/16×26-3/4 56-5/16×3-9/16×26-3/4 56-5/16×3-9/16×26-3/4 56-5/16×3-9/16×26-3/4 56-5/16×3-9/16×26-3/4
Net dim.(WxHxD) Net dim.(WxHxD) (1,430×90×680) (1,430×90×680) (1,430×90×680) (1,430×90×680) (1,430×90×680) (1,430×90×680)
mm in.(mm)
60×5-1/8×30-1/8 60×5-1/8×30-1/8 60×5-1/8×30-1/8 60×5-1/8×30-1/8 60×5-1/8×30-1/8 60×5-1/8×30-1/8
Panel Gross dim.(WxHxD) 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 1,525×130×765 Panel Gross dim.(WxHxD) (1,525×130×765) (1,525×130×765) (1,525×130×765) (1,525×130×765) (1,525×130×765) (1,525×130×765)

Net/gross kg 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 10.5/15 Net/gross lbs.(kg) 23/33(10.5/15) 23/33(10.5/15) 23/33(10.5/15) 23/33(10.5/15) 23/33(10.5/15) 23/33(10.5/15)

L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 L(flare) in.(mm) Ф1/4(6.35) Ф1/4(6.35) Ф1/4(6.35) Ф1/4(6.35) Ф3/8(9.52) Ф3/8(9.52)

Piping Piping
G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9 G(flare) in.(mm) Ф1/2(12.7) Ф1/2(12.7) Ф1/2(12.7) Ф1/2(12.7) Ф5/8(15.9) Ф5/8(15.9)
connections connections
Drain piping mm Drain piping ID 1(Ф25), OD Ф ID 1(Ф25), OD Ф ID 1(Ф25), OD Ф ID 1(Ф25), OD Ф ID 1(Ф25), OD Ф ID 1(Ф25), OD Ф
ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 ID Ф25, OD Ф32 in.(mm) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32)

Drain pump pumphead mm 750 750 750 750 750 750 Standard Controller - Wireless remote controller (RM05/BG(T)-A)

Standard Controller - Wireless remote controller (RM05/BG(T)-A)

Notes: Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal) 1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal)
3. Sound level is measured 1.4m below the unit. 3. Sound level is measured 4.59ft.(1.4m) below the unit.
25 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 26

Compact Four Way Cassette


Specifications

Model MDV-D22Q4/N1-A3 MDV-D28Q4/N1-A3 MDV-D36Q4/N1-A3 MDV-D45Q4/N1-A3

Power supply 1-phase, 220-240V, 50Hz

kW 2.2 2.8 3.6 4.5

Cooling capacity kcal/h 1,900 2,400 3,100 3,800

Btu/h 7,500 9,500 12,200 15,300

kW 2.4 3.2 4.0 5.0

kcal/h 2,000 2,700 3,400 4,300


Heating capacity

Btu/h 8,900 10,900 13,600 17,000

Cooling 51 52 58 58
Power input W
Heating 43 44 50 51

Cooling 0.175 0.175 0.21 0.21


Rated current A
Compact design, easy installation and maintenance Heating 0.175 0.175 0.21 0.21

m3/h 522/414/313 520/415/320 610/521/409 610/521/409


Extremely compact casing (570mm in width and depth)
Airflow rate(H/M/L)
makes it perfectly match with the ambient decoration. CFM 307/244/184 306/200/188 359/306/241 359/306/241
Little space is required for installation into a shallow
Sound level dB(A) 35.8/33.4/23.4 35.8/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8
ceiling.
Due to its compact body and light weight, all models Type R410A

can be installed without a hoist. Refrigerant


Control method EXV

630×265×575 630×265×575 630×265×575 630×265×575


Uniform air flow of four ways
Net dim.(WxHxD)
Quiet operation, soft air supply mm
Gross dim.(WxHxD) 675×285×675 675×285×675 675×285×675 675×285×675
Body

Net/gross kg 17.5/22 17.5/22 19/23.5 19/23.5


Diffuser

Net dim.(WxHxD) 647×50×647 647×50×647 647×50×647 647×50×647


3-D spiral fan blade mm
Panel Gross dim.(WxHxD) 705×113×705 705×113×705 705×113×705 705×113×705

Net/gross kg 3/5 3/5 3/5 3/5


Streamline plate ensures quietness The four air discharge port provides strong circulating
Advanced 3-D spiral fan design reduces the air air flow to cool or heat every corner of the room and L(flare) mm Ф6.35 Ф6.35 Ф6.35 Ф6.35

resistance and operation noise. realizes even temperature distribution; by choosing high Piping
G(flare) mm Ф12.7 Ф12.7 Ф12.7 Ф12.7
airflow mode, high ceiling application over 3m can get connections
equal comfort. Drain piping mm ID Ф20 ODФ25 ID Ф20 ODФ25 ID Ф20 ODФ25 ID Ф20 ODФ25

360° airflow outlet Drain pump pumphead mm 500 500 500 500

Standard Controller - Wireless remote controller (RM05/BG(T)E-A)


360°air outlet provides strong
circulating air flow to cool or
500mm
heat every corner of the room
Notes:
and realizes even
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal)
temperature distribution Drain up pump with 500mm pumphead fitted as 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal)

standard, max. up to 600mm head. 3. Sound level is measured 1.4m below the unit.
27 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 28

Four Way Cassette


Specifications Quiet operation, soft air supply
■ Streamline plate ensures quietness
Model MDV-D22Q4/VN1-A3 MDV-D28Q4/VN1-A3 MDV-D36Q4/VN1-A3 MDV-D45Q4/VN1-A3 ■ Advanced 3-D spiral fan design reduces the air
Power supply
resistance and operation noise.
1-phase, 220-240V 60Hz

kW 2.2 2.8 3.6 4.5


Diffuser
Cooling capacity kcal/h 1,900 2,400 3,100 3,800

Btu/h 7,500 9,600 12,300 15,400 3-D spiral fan blade

kW 2.4 3.2 4 5

kcal/h 2,100 2,700 3,400 4,300


Uniform air flow of four ways
Heating capacity
Four kinds of colors panel available
Btu/h 8,200 10,900 13,600 17,100

Cooling 51 52 58 58 The four air discharge port provides strong


Power input W circulating air flow to cool or heat every corner of
Heating 43 44 50 51
the room and realizes even temperature
Cooling 0.175 0.175 0.21 0.21
Rated current A distribution; by choosing high airflow mode, high
Heating 0.175 0.175 0.21 0.21 ceiling application over 3m can get equal comfort.
m3/h 532/397/292 539/408/310 632/496/359 632/496/359 (White) Standard (Black) Optional
Airflow rate(H/M/L) Four-way airflow(4-stage fan speed)
CFM 313/234/172 317/240/182 372/292/211 372/292/211

Sound level dB(A) 35.8/33.4/23.4 35.8/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8

Type R410A
Refrigerant
Control method EXV

Net dim.(WxHxD)
24-13/16×10-7/16×26-9/16 24-13/16×10-7/16×26-9/16 24-13/16×10-7/16×26-9/16 24-13/16×10-7/16×26-9/16
(630×265×675) (630×265×675) (630×265×675) (630×265×675)
(Gray) Optional (Blue) Optional
in.(mm)
Gross dim.(WxHxD) 26-9/16×11-1/4×26-9/16 26-9/16×11-1/4×26-9/16 26-9/16×11-1/4×26-9/16 26-9/16×11-1/4×26-9/16
Body (675×285×675) (675×285×675) (675×285×675) (675×285×675)
Easy trouble shooting Reserved multi-function ports
Net/gross lbs.(kg) 38.6/48.5(17.5/22) 38.6/48.5(17.5/22) 41.9/51.8(19/23.5) 41.9/51.8(19/23.5)
By adding digital tube displayer on the display board,
25-15/32×1-31/32×25-15/2 25-15/32×1-31/32×25-15/2 25-15/32×1-31/32×25-15/2 25-15/32×1-31/32×25-15/2
Net dim.(WxHxD) (647×50×647) (647×50×647) (647×50×647) (647×50×647) the Error Codes can be displayed directly on it which
in.(mm)
Panel Gross dim.(WxHxD) 27-3/4×4-7/16×27-3/4 27-3/4×4-7/16×27-3/4 27-3/4×4-7/16×27-3/4 27-3/4×4-7/16×27-3/4 helps to find and shoot the trouble.
To another room
(705×113×705) (705×113×705) (705×113×705) (705×113×705)
For duct
Net/gross lbs.(kg) 6.6/11(3/5) 6.6/11(3/5) 6.6/11(3/5) 6.6/11(3/5) Fresh Air Intake connecting

L(flare) in.(mm) Ф1/4(6.35) Ф1/4(6.35) Ф1/4(6.35) Ф1/4(6.35)


Piping
connections
G(flare) in.(mm) Ф1/2(12.7) Ф1/2(12.7) Ф1/2(12.7) Ф1/2(12.7)
High lift pump
Drain piping in.(mm) ID 3/4(Ф20), OD Ф1(Ф25) ID 3/4(Ф20), OD Ф1(Ф25) ID 3/4(Ф20), OD Ф1(Ф25) ID 3/4(Ф20), OD Ф1(Ф25)
Drain pump can take up the condenser water to Ultra-thin machine body for easy installation and
Standard Controller Wireless remote controller (RM05/BG(T)E-A) 750mm which helps to make easier installation of maintenance, min. 230mm in height.
the drain piping system.
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal)
3.Sound Level is measured 4.59ft.(1.4m) below the unit.

750mm 230mm
29 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 30

Specifications Specifications
Model MDV-D28Q4/N1-D MDV-D36Q4/N1-D MDV-D45Q4/N1-D MDV-D56Q4/N1-D MDV-D71Q4/N1-D Model MDV-D28Q4/VN1-D MDV-D36Q4/VN1-D MDV-D45Q4/VN1-D MDV-D56Q4/VN1-D MDV-D71Q4/VN1-D

Power supply 1-phase, 220-240V, 50Hz Power supply 1-phase, 220-240V, 60Hz

kW 2.8 3.6 4.5 5.6 7.1 kW 2.8 3.6 4.5 5.6 7.1
Cooling capacity Cooling capacity kcal/h 2,400 3,100 3,800 4,800 6,100
kcal/h 2,400 3,100 3,800 4,800 6,100
Btu/h 9,500 12,200 15,300 19,100 24,200 Btu/h 9,500 12,300 15,400 19,100 24,200

kW 3.2 4.0 5.0 6.3 8.0 kW 3.2 4 5 6.3 8

Heating capacity kcal/h 2,700 3,400 4,300 5,400 6,800 Heating capacity kcal/h 2,700 3,400 4,300 5,400 6,800

Btu/h 10,900 13,600 17,000 21,500 27,300 Btu/h 10,900 13,600 17,100 21,500 27,300

Cooling 80 80 75 75 82 Cooling 60 60 71 71 94
Power input W Power input W
Heating 80 80 75 75 82 Heating 60 60 71 71 94

Cooling 0.4 0.4 0.4 0.4 0.5 Cooling 0.4 0.4 0.4 0.4 0.5
Rated current A Rated current A
Heating 0.4 0.4 0.4 0.4 0.5 Heating 0.4 0.4 0.4 0.4 0.5

m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1,157/955/749 m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1,157/955/749
Airflow rate(H/M/L) Airflow rate(H/M/L)
CFM 498/450/376 498/450/376 508/444/387 508/444/387 680/562/440 CFM 499/451/377 499/451/377 509/444/387 509/444/387 681/562/441
Sound level Sound level dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39
dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39
Type R410A Type R410A
Refrigerant Refrigerant
Control method EXV Control method EXV
33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16
Net dim.(WxHxD) 840x230x840 840x230x840 840x230x840 840x230x840 840x230x840 Net dim.(WxHxD) (840×230×840) (840×230×840) (840×230×840) (840×230×840) (840×230×840)
mm in.(mm)
Gross dim.(WxHxD) 37-5/8×9-3/4×37-5/8 37-5/8×9-3/4×37-5/8 37-5/8×9-3/4×37-5/8 37-5/8×9-3/4×37-5/8 37-5/8×9-3/4×37-5/8
Body Gross dim.(WxHxD) 955X247X955 955X247X955 955X247X955 955X247X955 955X247X955 Body (955×247×955) (955×247×955) (955×247×955) (955×247×955) (955×247×955)
Net/gross kg 24/28 24/28 26/30 26/30 26/30
Net/gross lbs.(kg) 52.9/61.7(24/28) 52.9/61.7(24/28) 52.9/61.7(24/28) 52.9/61.7(24/28) 52.9/61.7(24/28)
Net dim.(WxHxD) 37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8
Net dim.(WxHxD) 950x46x950 950x46x950 950x46x950 950x46x950 950x46x950 (950×46×950) (950×46×950) (950×46×950) (950×46×950) (950×46×950)
mm in.(mm)
Panel Gross dim.(WxHxD) 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8
Panel Gross dim.(WxHxD) 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 (1,000×60×1,000) (1,000×60×1,000) (1,000×60×1,000) (1,000×60×1,000) (1,000×60×1,000)
Net/gross kg Net/gross lbs.(kg) 13.2/17.6(6/8) 13.2/17.6(6/8) 13.2/17.6(6/8) 13.2/17.6(6/8) 13.2/17.6(6/8)
6/8 6/8 6/8 6/8 6/8
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 L(flare) in.(mm) Ф1/4(6.35) Ф1/4(6.35) Ф1/4(6.35) Ф3/8(9.52) Ф3/8(9.52)
Piping Piping
G(flare) mm G(flare) in.(mm) Ф1/2(12.7) Ф1/2(12.7) Ф1/2(12.7) Ф5/8(15.9) Ф5/8(15.9)
Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9 connections
connections
Drain piping in.(mm) ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф
Drain piping mm IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32)
mm Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
Drain pump pumphead 750 750 750 750 750
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Model MDV-D80Q4/N1-D MDV-D90Q4/N1-D MDV-D100Q4/N1-D MDV-D112Q4/N1-D MDV-D140Q4/N1-D Model MDV-D80Q4/VN1-D MDV-D90Q4/VN1-D MDV-D100Q4/VN1-D MDV-D112Q4/VN1-D MDV-D140Q4/VN1-D

Power supply Power supply 1-phase, 220-240V, 60Hz


1-phase, 220-240V, 50Hz

kW 8.0 9.0 10.0 11.2 14.0 kW 8 9 10 11.2 14


Cooling capacity Cooling capacity kcal/h 6,900 7,700 8,600 9,600 12,000
kcal/h 6,800 7,700 8,600 9,600 12,000
Btu/h 27,300 30,700 34,100 38,200 47,800 Btu/h 27,300 30,700 34,100 38,200 47,800

kW 9.0 10.0 11.0 12.5 15.0 kW 9 10 11 12.5 15

Heating capacity kcal/h 7,700 8,600 9,400 10,700 12,900 Heating capacity kcal/h 7,700 8,600 9,400 10,700 12,900

Btu/h 30,700 34,100 37,500 42,600 51,200 Btu/h 30,700 34,100 37,500 42,600 51,200

Cooling 97 160 160 160 170 Cooling 94 173 173 173 186
Power input W Power input W
Heating 97 160 160 160 170 Heating 94 173 173 173 186

Cooling 0.5 0.7 0.7 0.7 0.8 Cooling 0.5 0.7 0.7 0.7 0.8
Rated current A Rated current A
Heating 0.5 0.7 0.7 0.7 0.8 Heating 0.5 0.7 0.7 0.7 0.8

m /h
3 1,236/973/729 1,540/1,300/1,120 1,540/1,300/1,120 1,540/1,300/1,120 1,800/1,500/1,280 m3/h 1,236/973/729 1,590/1,300/1,090 1,590/1,300/1,090 1,590/1,300/1,090 1,678/1,358/1,115
Airflow rate(H/M/L) Airflow rate(H/M/L)
CFM 727/572/429 906/765/659 906/765/659 906/765/659 1059/883/753 CFM 727/573/429 936/765/642 936/765/642 936/765/642 988/799/656
Sound level Sound level dB(A) 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44
dB(A) 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44
Type R410A Type R410A
Refrigerant Refrigerant
Control method EXV Control method EXV
Net dim.(WxHxD) 33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16 33-1/16×9-1/16×33-1/16
Net dim.(WxHxD) 840x230x840 840x300x840 840x300x840 840x300x840 840x300x840 in.(mm) (840×230×840) (840×230×840) (840×230×840) (840×230×840) (840×230×840)
mm 37-9/16×9-3/4×37-9/16 37-9/16×9-3/4×37-9/16 37-9/16×9-3/4×37-9/16 37-9/16×9-3/4×37-9/16 37-9/16×9-3/4×37-9/16
Body Gross dim.(WxHxD) Body Gross dim.(WxHxD) (955×247×955) (955×247×955) (955×247×955) (955×247×955) (955×247×955)
955X247X955 955X317X955 955X317X955 955X317X955 955X317X955
Net/gross kg Net/gross lbs.(kg) 57.3/66(26/30) 70.5/81.6(32/37) 70.5/81.6(32/37) 70.5/81.6(32/37) 70.5/81.6(32/37)
26/30 32/37 32/37 32/37 32/37
37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8 37-3/8×1-13/16×37-3/8
Net dim.(WxHxD) Net dim.(WxHxD) (950×46×950) (950×46×950) (950×46×950) (950×46×950) (950×46×950)
950x46x950 950x46x950 950x46x950 950x46x950 950x46x950 in.(mm)
mm 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8 39-3/8×3-9/16×39-3/8
Panel Gross dim.(WxHxD) Panel Gross dim.(WxHxD)
1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 1,000x60x1,000 (1,000×60×1,000) (1,000×60×1,000) (1,000×60×1,000) (1,000×60×1,000) (1,000×60×1,000)
Net/gross kg Net/gross lbs.(kg) 13.2/17.6(6/8) 13.2/17.6(6/8) 13.2/17.6(6/8) 13.2/17.6(6/8) 13.2/17.6(6/8)
6/8 6/8 6/8 6/8 6/8
L(flare) mm L(flare) in.(mm) Ф3/8(9.52) Ф3/8(9.52) Ф3/8(9.52) Ф3/8(9.52) Ф3/8(9.52)
Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Piping
Piping
G(flare) mm G(flare) in.(mm) Ф5/8(15.9) Ф5/8(15.9) Ф5/8(15.9) Ф5/8(15.9) Ф5/8(15.9)
Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 connections
connections ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф ID 1-1/8(Ф28.5), OD Ф
Drain piping mm Drain piping in.(mm) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32) 1-1/4(Ф32)
IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32 IDФ28.5 ODФ32
mm Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
Drain pump pumphead 750 750 750 750 750
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Notes: Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal) 1. Nominal cooling capacities are based on the following conditions: return air temp. : 27°CDB,19°CWB,outdoor temp.:35°CDB, equivalent ref. Piping: 8m(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB,outdoor temp.: 7°CDB, 6°CWB,equivalent ref. Piping: 8m(horizontal)
3. Sound Level is measured 1.4m below the unit. 3. Sound Level is measured 4.59ft. (1.4m) below the unit.
31 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 32

Model
Low Static Pressure Duct
MDV-D18T3/N1-B MDV-D22T3/N1-B MDV-D28T3/N1-B MDV-D36T3/N1-B MDV-D45T3/N1-B MDV-D56T3/N1-B

Power Supply 220~240V-1Ph-50Hz

kW 1.8 2.2 2.8 3.6 4.5 5.6

Cooling kcal/h 1,547 1,891 2,407 3,095 3,869 4,815

btu/h 6,100 7,500 9,500 12,200 15,300 19,100


Capacity
kW 2.2 2.6 3.2 4.0 5.0 6.3
Heating kcal/h 1,891 2,235 2,751 3,439 4,299 5,416

btu/h 7,500 8,900 10,900 13,600 17,000 21,500

Input W 40 40 40 40 40 56
Power (Cooling)
Rated Current A 0.17 0.17 0.17 0.17 0.17 0.24

Input W 40 40 40 40 40 56
Power (Heating)
Rated Current A 0.17 0.17 0.17 0.17 0.24 0.24

m3/h 446/323/250 446/323/250 527/359/267 527/359/267 767/634/512 767/634/512


Indoor air flow (H/M/L)
cfm 263/190/147 263/190/147 310/211/157 310/211/157 451/373/301 451/373/301

ESP (external static pressure) Pa 5 5 5 5 5 5

Sound Pressure (Hi/Mid/Lo) dB(A) 33/27/21 34/29/21 36/34/30 36/34/30 37/35/31 37/35/31

Type R410A
Refrigerant
Wide capacity range Control Method EXV

Net dimension W×H×D mm 850×190×405 850×190×405 850×190×405 850×190×405 1,030×190×430 1,030×190×430


The capacity range from 1.8KW to 5.6KW, six model. Packing dimension W×H×D mm 903×277×445 903×277×445 903×277×445 903×277×445 1,084×277×472 1,084×277×472

Net/Gross Weight kg 11.5/14.5 11.5/14.5 11.5/14.5 11.5/14.5 14 /17.5 14/17.5


Low sound level Liquid (Flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52

Piping Connections Gas (Flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9

Drain piping mm IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20 IDΦ15 ODΦ20
Utilize the cross blow fan, the Drain pump pumphead mm 750

lowest noise is 21dB (A). Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Excellent choice for hotels Model MDV-D18T3/N1-B MDV-D22T3/N1-B MDV-D28T3/N1-B MDV-D36T3/N1-B MDV-D45T3/N1-B MDV-D56T3/N1-B

and other sound sensitive Power Supply 220~240V-1Ph-60Hz

kW 1.8 2.2 2.8 3.6 4.5 5.6


places. Cooling kcal/h 1,547 1,891 2,407 3,095 3,869 4,815
btu/h 6,100 7,500 9,500 12,200 15,300 19,100
Capacity
kW 2.2 2.6 3.2 4.0 5.0 6.3
Heating kcal/h 1,891 2,235 2,751 3,439 4,299 5,416

More Smooth airflow with less turbulence Convenient installation Input


btu/h
W
7,500
32
8,900
32
10,900
35
13,600
35
17,000
43
21,500
43
Power (Cooling)
Runing Current A 0.17 0.17 0.17 0.17 0.17 0.24
Thanks to the multiple-blade fan rotor and the air guide The EXV is fixed beside of the indoor unit Input 32 32 35 35
W 43 43
Power (Heating)
design, the airflow is getting smoother and more com- Suction chamber is included as stand.ard Runing Current A 0.17 0.17 0.17 0.17 0.24 0.24
m3/h 452/409/310 452/409/310 521/460/372 521/460/372 831/712/591 831/712/591
fortable equipment Indoor air flow (H/M/L)
CFM 266/240/182 266/240/182 306/270/219 306/270/219 489/419/347 489/419/347
EXP (external static pressure) Pa 5 5 5 5 5 5

Slim,lightweight,and compact design Options Sound Pressure (Hi/Mid/Lo)


Type
dB(A) 33/27/21 34/29/21 36/34/30
R410A
36/34/30 37/35/31 37/35/31

Refrigerant
Control Method EXV

33-15/32×7-31/ 33-15/32×7-31/ 33-15/32×7-31/ 33-15/32×7-31/ 40-35/64×7-31/ 40-35/64×7-31/


Min.5mm Net dimension W×H×D in.(mm) 64×15-15/16 64×15-15/16 64×15-15/16 64×15-15/16 64×16-59/64 64×16-59/64
(850×190×405) (850×190×405) (850×190×405) (850×190×405) (1,030×190×430) (1,030×190×430)
35-35/64×10-29/ 35-35/64×10-29/ 35-35/64×10-29/ 35-35/64×10-29/ 42-43/64×10-29/ 42-43/64×10-29/32×
Packing dimension W×H×D in.(mm) 32×17-33/64 32×17-33/64 32×17-33/64 32×17-33/64 32×18-37/64 18-37/64
750mm (903×277×445) (903×277×445) (903×277×445) (903×277×445) (1,084×277×472) (1,084×277×472)
190mm
Net/Gross Weight lbs.(kg) 25.4/32.(11.5/14.5) 25.4/32.(11.5/14.5) 25.4/32.(11.5/14.5) 25.4/32.(11.5/14.5) 30.9/38.6(14 /17.5) 30.9/38.6(14 /17.5)

Liquid (Flare) in.(mm) Φ1/4(Φ6.4) Φ1/4(Φ6.4) Φ1/4(Φ6.4) Φ1/4(Φ6.4) Φ3/8(Φ9.53) Φ3/8(Φ9.53)

Gas (Flare) in.(mm) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Φ5/8(Φ15.9) Φ5/8(Φ15.9)


Piping Connections
Drop-Ceiling OD 25/32(Ф20) OD 25/32(Ф20) OD 25/32(Ф20) OD 25/32(Ф20) OD 25/32(Ф20) OD 25/32(Ф20)
ceiling Drain piping in.(mm)
ID19/32(Φ15) ID19/32(Φ15) ID19/32(Φ15) ID19/32(Φ15) ID19/32(Φ15) ID19/32(Φ15)

Standard Controller Wireless remote controller (RM05/BG(T)E-A)


Uniform 190mm in height, compact design for easy With a drain-up pump as an optional acces- Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
locate where space over ceiling is limited, sory (750 mm pumphead).
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
The whole body adopts fireproof plastic material, 3. Sound Level is measured 4.59ft. (1.4m) below the unit.

the minimum weight is 11.5kg * external static pressure are based on high speed indoor air flow.
* Specifications are subject to change without prior notice for product improvement.
33 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 34

Concealed Duct Unit (A5 Type) Model MDV-D22T2/N1-BA5 MDV-D28T2/N1-BA5 MDV-D36T2/N1-BA5 MDV-D45T2/N1-BA5 MDV-D56T2/N1-BA5

Wide capacity range Power Supply

kW 2.2 2.8
220~240V-1Ph-50Hz

3.6 4.5 5.6

The capacity ranges from 2.2KW to 14.0KW, totally 10 models. Cooling kcal/h 1,891 2,407 3,095 3,869 4,815

btu/h 7,500 9,500 12,200 15,300 19,100


Capacity

Compact size Heating


kW

kcal/h
2.6

2,235
3.2

2,751
4

3,439
5

4,299
6.3

5,416

btu/h 8,900 10,900 13,600 17,000 21,500

Min.5mm Input W 59 57 61 92 92
Power (Cooling)
Rated Current A 0.28 0.28 0.28 0.5 0.5

Input W 59 57 61 92 92
Power (Heating)
210mm Rated Current A 0.28 0.28 0.28 0.5 0.5
or270mm m3/h 570/530/410/320 570/530/410/320 570/530/410/320 958/850/667/583 958/850/667/583
Indoor air flow (H/M/L)
cfm 335/312/241/188 335/312/241/188 335/312/241/188 563/500/392/343 563/500/392/343

ESP (external static pressure) Pa 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30)


Drop-Ceiling Sound Pressure (Hi/Mid/Lo) dB(A) 38/35/32 38/35/32 40/38/36 41/38.9/36 41/38.9/36

Type R410A
Refrigerant
Only 210 mm (22~56 models) or 270mm (71 to 140 model) in height. Control Method EXV

The EXV is built-in design of the indoor unit, main body without an extra throttle kit box. Net dimension W×H×D mm 700x210x570 700x210x570 700x210x570 920X210X570 920X210X570

Packing dimension W×H×D mm 915x290x655 915x290x655 915x290x655 1,135X290X655 1,135X290X655


kg
Two external static pressure settings for added flexibility
Net/Gross Weight 21.5/26 21.5/26 22/27 27/32 27/32

Liquid (Flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52


mm
Four speed fan motor (Super high speed as an optional) Piping Connections Gas (Flare) Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ16

Drain piping mm IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32
Change the wiring connection from ‘SH’ to ‘Hi’ to change the ESP. mm
Drain pump pumphead 750

Standard Controller -
Convenient installation
Wired controller KJR-12B/DP(T)-E/KJR-10B/DP(T)-E(6 meters connection wire)

The EXV is fixed inside of the indoor unit


Model MDV-D71T2/N1-BA5 MDV-D80T2/N1-BA5 MDV-D90T2/N1-BA5 MDV-D112T2/N1-BA5 MDV-D140T2/N1-BA5
Standard filter placed in an aluminum frame, which is removable downward from bottom.
Suction chamber is included as standard equipment Power Supply 220~240V-1Ph-50Hz

kW 7.1 8 9 11.2 14
Fresh air hole, air inlet/outlet flange are standard for easy duct connection.
Cooling kcal/h 6,105 6,879 7,739 9,630 12,037
Air inlet from back is standard and from bottom as optional with the same connectable duct.
btu/h 24,200 27,300 30,700 38,200 47,800
Capacity
kW 8 9 10 12.5 15.5
Drain pump is equipped as standard
Air intake from back Air intake from below accessory with 750 mm pumphead.
Heating kcal/h 6,879 7,739 8,598 10,748 13,327

btu/h 27,300 30,700 34,100 42,600 52,900

Input W 149 198 200 313 274


Power (Cooling)
Rated Current A 0.7 1 1 1.8 1.55
750mm
Input W 149 198 200 313 274
Power (Heating)
Rated Current A 0.7 1 1 1.8 1.55

m3/h 1,207/1,050/905/821 (1,400)1,226/1,018/861 1,400/1,230/1,019/859 (1,750)/1,752/1,552/1,389 1,789/1,918/1,539/1,250


Indoor air flow (H/M/L)
ceiling cfm 710/618/532/483 917/795/687/608 917/795/687/608 1,214/1,059/921/824 1,258/1,118/967/827

ESP (external static pressure) Pa 10(10~30) 20(10~50) 20(10~50) 40(10~80) 40(10~100)

Flexible control and convenient for maintenance Sound Pressure (Hi/Mid/Lo) dB(A) 43.4/40/36 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0

Type R410A
Refrigerant
Control Method EXV
Standard Wired remote controller KJR-12B(FOLLOW ME)/KJR-10B. Net dimension W×H×D mm 920X210X570 1,140X270X710 1,140X270X710 1,140X270X710 1,200X300X800
The display board is connected with the E-box in factory, easier trouble-shooting by LED display. Packing dimension W×H×D mm 1,135X350X655 1,355X350X795 1,355X350X795 1,355X350X795 1,385X375X920

The Electrical control box can be removed 1m away from the unit, easy to access when needs maintenance. Net/Gross Weight kg 30/34 38/46.5 40/48 40/48 49/58

Liquid (Flare) mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52


(Should be required by client in advance and done by Midea CAC in factory).
Piping Connections Gas (Flare) mm Φ16 Φ16 Φ16 Φ16 Φ16
Standard functional port such as Remote On/Off Dry contact switch and Alarm signal output (220V). Drain piping mm IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32

Drain pump pumphead mm 750

Standard Controller - Wired controller KJR-12B/DP(T)-E/KJR-10B/DP(T)-E(6 meters connection wire)


MANUAL
Notes:
RUN TIMER DEF ALARM MANUAL OPERATION TIMER DEF./FAN ALARM 1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured 1.4m below the air out-let.

22~56 model 71~140 model * external static pressure are based on high speed indoor air flow.
* Specifications are subject to change without prior notice for product improvement.
35 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 36

Model MDV-D22T2/VN1-BA5 MDV-D28T2/VN1-BA5 MDV-D36T2/VN1-BA5 MDV-D45T2/VN1-BA5 MDV-D56T2/VN1-BA5 High Static Pressure Duct
Power Supply 220~240V-1Ph-60Hz

kW 2.2 2.8 3.6 4.5 5.6

Cooling kcal/h 1,891 2,407 3,095 3,869 4,815 Wide capacity range
btu/h 7,500 9,500 12,200 15,300 19,100
Capacity
kW 2.6 3.2 4 5 6.3 The capacity ranges from 7.1KW to
Heating kcal/h 2,235 2,751 3,439 4,299 5,416
16.0KW, totally six models.
btu/h 8,900 10,900 13,600 17,000 21,500

Input W 66 77 72 101 100


Power (Cooling)
Runing Current A 0.28 0.28 0.28 0.5 0.5

Input W 66 77 72 101 100


Power (Heating)
Runing Current A 0.28 0.28 0.28 0.5 0.5

m3/h (543)/476/399/335 (548)/467/413/353 (550)/534/452/391 813/746/558/470 808/750/563/470

Flexible duct design


Indoor air flow (H/M/L)
cfm 320/280/234/197 322/275/243/207 323/314/266/230 478/439/328/276 475/441/331/276

EXP (external static pressure) Pa 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30)

Sound Pressure (Hi/Mid/Lo) dB(A) 38/35/32 38/35/32 40/38/36 41/38.9/36 41/38.9/36 Four speed fan motor, medium high speed as an option.
Refrigerant
Type R410A
External static pressure can be up to 196Pa.
Control Method EXV

in.(mm) 27-9/16×8-17/64×22-7/16 27-9/16×8-17/64×22-7/16 27-9/16×8-17/64×22-7/16 27-9/16×8-17/64×22-7/16 36-7/32×8-1/4×22-7/16


Net dimension W×H×D the longest distance
(700×210×570) (700×210×570) (700×210×570) (700×210×570) (920×210×570)
of air supply is 14m
Fresh air in take
Packing dimension W×H×D in.(mm) 36-1/32×11-2764×25-25/32 36-1/32×11-2764×25-25/32 36-1/32×11-2764×25-25/32 36-1/32×11-2764×25-25/32 44-11/16×11-7/16×25-13/1
(915×290×655) (915×290×655) (915×290×655) (915×290×655) 6(1,135×290×655) Min.
420mm 450mm
Net/Gross Weight lbs.(kg) 47.4/57.3(21.5/26) 47.4/57.3(21.5/26) 48.5/59.5(22/27) 59.5/70.5(27/32) 59.5/70.5(27/32)

Liquid (Flare) in.(mm) Φ1/4(Φ6.35) Φ1/4(Φ6.35) Φ1/4(Φ6.35) Φ1/4(Φ6.35) Φ3/8(Φ9.52)


Piping Connections
INDOOR UNIT
Gas (Flare) in.(mm) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Φ5/8(Φ15.9)

Drain piping in.(mm) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) Air supply The height of air Air return
supply is 6.5m
Standard Controller Wired controller KJR-12B/DP(T)-E/KJR-10B/DP(T)-E(6 meters connection wire) INDOOR UNIT

Model MDV-D71T2/VN1-BA5 MDV-D80T2/VN1-BA5 MDV-D90T2/VN1-BA5 MDV-D112T2/VN1-BA5 MDV-D140T2/VN1-BA5


The max distance of air supply is about 14m while the height of air supply is about 6.5m.
Power Supply 220~240V-1Ph-60Hz With 420mm thickness body, the minimum distance above the ceiling is 450mm.
kW 7.1 8 9 11.2 14

Cooling kcal/h 6,105 6,879 7,739 9,630 12,037

Capacity
btu/h 24,200 27,300 30,700 38200 47800 Added flexibility with four speed fan
kW 8 9 10 12.5 15.5
Heating kcal/h 6,879 7,739 8,598 10,748 13,327 Just exchange the wiring connection of ‘MH’ and ‘Me’.
btu/h 27,300 30,700 34,100 42,600 52,900

Convenient installation
Input W 165 133 134 378 352
Power (Cooling)
Runing Current A 0.7 1 1 1.8 1.55

Input W 165 133 134 378 352


Power (Heating)
Runing Current A 0.7 1 1 1.8 1.55
The EXV is fixed inside the indoor unit, no need extra connection.
m /h
3 1,111/976/811/694 1,400/1,226/1,018/861 1,400/1,230/1,019/859 1,750/1,752/1,552/1,389 1,789/1,918/1,539/1,250 Standard filter placed in an aluminum frame, which is removable downward from bottom.
Indoor air flow (H/M/L)
cfm 653/574/477/408 824/721/599/507 824/724/600/505 1,030/1,031/913/817 1,052/1,129/905/735 Flange for air in/outlet duct connection is standard.
EXP (external static pressure) Pa 10(10~30) 20(10~50) 20(10~50) 40(10~80) 40(10~100)

Sound Pressure (Hi/Mid/Lo) dB(A) 43.4/40/36 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0
Flexible control and convenient for maintenance
Type R410A
Refrigerant
Control Method EXV Standard Wired remote controller KJR-10B/KJR-12B, and wireless remote controller R05 is as an option.
Net dimension W×H×D in.(mm) 36-7/32×8-1/4×22-7/16 44-7/8×10-5/8×27-61/64 44-7/8×10-5/8×27-61/64 44-7/8×10-5/8×27-61/64 47-1/4×11-13/16×31-1/2 The display board is connected with the E-box in factory, easier trouble-shooting by LED display.
(920×210×570) (1,140×270×710) (1,140×270×710) (1,140×270×710) (1,200×300×800)
Easy access filters both in rear & bottom
Packing dimension W×H×D in.(mm) 44-11/16×11-7/16×25-13/1 53-11/32×13-25/32×31-19/ 53-11/32×13-25/32×31-19/ 53-11/32×13-25/32×31-19/
6(1,135×290×655) 64(1,355×350×795) 64(1,355×350×795) 64(1,355×350×795)
54-9/16×14-3/4×36-1/4
(1,385×375×920)
Standard functional port such as remote on/off dry contact.
Net/Gross Weight

Liquid (Flare)
lbs.(kg)

in.(mm)
66.1/75.0(30/34)

Φ3/8(Φ9.52)
88.2/105.8(40/48)

Φ3/8(Φ9.52)
88.2/105.8(40/48)

Φ3/8(Φ9.52)
88.2/105.8(40/48)

Φ3/8(Φ9.52)
108.0/127.9(49/58)

Φ3/8(Φ9.52)
Option:
Piping Connections Gas (Flare) in.(mm) Φ5/8(Φ15.9) Φ5/8(Φ15.9) Φ5/8(Φ15.9) Φ5/8(Φ15.9) Φ5/8(Φ15.9)
Drain piping in.(mm) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) OD 1-9/32(Ф32) ID 1(Ф25) Optional drain pumps with 750 mm pumphead.
Standard Controller Wired controller KJR-12B/DP(T)-E/KJR-10B/DP(T)-E(6 meters connection wire)

750mm

Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured 4.59ft.(1.4m) below the air out-let. ceiling
* External static ressure are based on high speed indoor air flow.
* Specifications are subject to change without prior notice for product improvement.
37 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 38

Ceiling & floor


Model MDV-D71T1/N1-B MDV-D80T1/N1-B MDV-D90T1/N1-B MDV-D112T1/N1-B MDV-D140T1/N1-B MDV-D160T1/N1-B

Power Supply 220~240V-1Ph-50Hz

kW 7.1 8 9 11.2 14 16

Cooling kcal/h 6,105 6,879 7,739 9,630 12,037 13,757

btu/h 24,200 27,300 30,700 38,200 47,800 54,600


Capacity
kW 8 9 10 12.5 16 18
Heating kcal/h 6,879 7,739 8,598 10,748 13,757 15,477

btu/h 27,300 30,700 34,100 42,600 54,600 61,400

Input W 263 263 423 524 627 832


Power (Cooling)
Rated Current A 1.1 1.1 1.8 2.3 2.7 3.6

Input W 263 263 423 524 627 832


Power (Heating)
Rated Current A 1.1 1.1 1.8 2.3 2.7 3.6

m3/h 1,510/1,399/1,236 1,500/1,396/1,221 1,936/1,721/1,511 2,117/1,950/1,644 2,988/2,670/2,229 3,890/3,200/2,700


Indoor air flow (H/M/L)
cfm 889/823/727 883/822/719 1,139/748/889 1,246/1,147/968 1,758/1,572/1312 2,290/1,883/1,589

ESP (external static pressure) Pa 40(30~ 196) 40(30~ 196) 40(30~ 196) 50(30~ 196) 50(30~ 196) 50(30~ 196)

Sound Pressure (Hi/Mid/Lo) dB(A) 48/46/44 48/46/44.5 52/49/47 52/49/47 53/50/48 54/52/50

Panel with LED display


Type R410A
Refrigerant
Control Method EXV

Net dimension W×H×D mm 952×420×690 952×420×690 952×420×690 952×420×690 1,200×400×600 1,200×400×600


Packing dimension W×H×D mm 1,102×450×768 1,102×450×768 1,102×450×768 1,102×450×768 1,430×450×768 1,430×450×768 The front panel and display panel have different colors for choose: white and brown for big panel, blue and
Net/Gross Weight kg 45/50 45/50 46.5/52.4 50.6/56 68/70 70/77.5 brown for small panel, and the other colors can be customized according to the customers’ demands.
Liquid (Flare) mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52

Piping Connections Gas (Flare) mm Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Φ15.9 Convenient for installation
Drain piping mm IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32 IDФ25 ODФ32
Drain pump pumphead mm 750 The ceiling type can be easily installed into a corner of
Standard Controller - Wire controller KJR-10B/DP(T)-E (6m wrie is standard) Wire controller KJR-12B/DP(T)-E (6m wrie is standard)
the ceiling even if the ceiling is very narrow
It is especially useful when installation of an air
Model MDV-D71T1/VN1-B MDV-D80T1/VN1-B MDV-D90T1/VN1-B MDV-D112T1/VN1-B MDV-D140T1/VN1-B MDV-D160T1/VN1-B conditioner in the center of the ceiling is impossible
Power Supply 220~240V-1Ph-60Hz
due to a structure such as one lighting
kW 7.1 8 9 11.2 14 16 The unit can be installed either horizontally on the
Cooling kcal/h 6,105 6,879 7,739 9,630 12,037 13,757 ceiling or vertically against the wall.
btu/h 24,200 27,300 30,700 38,200 47,800 54,600
Capacity
kW 8 9 10 12.5 16 18 Low noise, creates quiet and comfortable environment.
Heating kcal/h 6,879 7,739 8,598 10,748 13,757 15,477
btu/h 27,300 30,700 34,100 42,600 54,600 61,400
>20
Drop ceiling
Input W 263 263 423 524 627 832
Power (Cooling)
Runing Current A 1.1 1.1 1.8 2.3 2.7 3.6
Input W 263 263 423 524 627 832 198mm
Power (Heating)
Runing Current A 1.1 1.1 1.8 2.3 2.7 3.6
m3/h 1,758/1,568/1,342 1,602/1,494/1,302 2,250/2,020/1,595 2,250/2,020/1,595 3,030/2,711/2,490 3,030/2,711/2,490
Indoor air flow (H/M/L)
cfm 1,034/923/790 943/879/766 1,324/1,189/939 1,324/1,189/939 1,783/1,595/1,465 1,783/1,595/1,465
Air Outlet
EXP (external static pressure) Pa 40(30~196) 40(30~196) 40(30~196) 50(30~ 196) 50(30~ 196) 50(30~ 196)
Sound Pressure (Hi/Mid/Lo) dB(A) 48/46/44 48/46/44.5 52/49/47 52/49/47 53/50/48 54/52/50 Slim and sleek design starting at just 30kg in weight means quick,easy & neat installation.
Type R410A Low noise operation, lowest to 36 dB(A)
Refrigerant
Control Method EXV

Net dimension W×H×D in.(mm)


37-31/64×16-17/32×27-11/64 47-1/4×15-3/4×23-5/8 Auto swing and wide angle air flow
(952×420×690) (1,200×400×600)
43-25/64×-17/32×27-11/64 56-19/64×-17/32×27-11/64 Auto Swing & Wide-angle Airflow
Packing dimension W×H×D in.(mm)
(1,102×450×768) (1,430×450×768)
1.The unit has auto horizontal swing and auto vertical swing function,
Net/Gross Weight lbs.(kg) 46.5/52 46.5/52 50/56.5 50/56.5 69.5/76 69.5/76
Liquid (Flare) in.(mm) Ф3/8(Ф9.52) Ф3/8(Ф9.52) Ф3/8(Ф9.52) Ф3/8(Ф9.52) Ф3/8(Ф9.52) Ф3/8(Ф9.52)
which supplies more even and comfortable airflow.
Piping Connections
Gas (Flare) in.(mm) Ф5/8(Ф15.9) Ф5/8(Ф15.9) Ф5/8(Ф15.9) Ф5/8(Ф15.9) Ф5/8(Ф15.9) Ф5/8(Ф15.9) 2.Three air flow speed: high/middle/low, double air guides.
OD 1-9/32(Ф32) OD 1-9/32(Ф32) OD 1-9/32(Ф32) OD 1-9/32(Ф32) OD 1-9/32(Ф32) OD 1-9/32(Ф32)
Drain piping in.(mm)
ID 1(Ф25) ID 1(Ф25) ID 1(Ф25) ID 1(Ф25) ID 1(Ф25) ID 1(Ф25) 3.Adoption of the electronic expansion valve, ensure precise flow
Standard Controller - Wire controller KJR-10B/DP(T)-E (6m wrie is standard) Wire controller KJR-12B/DP(T)-E (6m wrie is standard) control, as well lower modulation noise when EXV operating.
Notes:
4.Smoother airflow with less turbulence. Owing to the multiple-blade
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) fan and the air guide design, the airflow is getting smoother and more
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured 4.59ft.(1.4m) from the air out-let. comfortable.
* external static pressure are based on high speed indoor air flow.

* Specifications are subject to change without prior notice for product improvement.
39 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 40

Model MDV-D36DL/N1-C MDV-D45DL/N1-C MDV-D56DL/N1-C MDV-D71DL/N1-C Model MDV-D36DL/N1-C MDV-D45DL/N1-C MDV-D56DL/N1-C MDV-D71DL/N1-C

Power supply 1-phase, 220-240V, 50Hz Power supply 220~240V-1Ph-60Hz

kW 3.6 4.5 5.6 7.1 kW 3.6 4.5 5.6 7.1


Cooling capacity kcal/h 3,100 3,800 4,800 6,100 Cooling capacity kcal/h 3,100 3,800 4,800 6,100
Btu/h 12,200 15,300 19,100 24,200 Btu/h 12,200 15,300 19,100 24,200
kW 4 5 6.3 8 kW 4 5 6.3 8
Heating capacity kcal/h 3,400 4300 5,400 6,800 Heating capacity kcal/h 3,400 4300 5,400 6,800

Btu/h 13,600 17,000 21,500 27,300 Btu/h 13,600 17,000 21,500 27,300

Cooling 49 120 122 125 Cooling 49 147 147 147


Power input W Power input W
Heating 49 120 122 125 Heating 49 147 147 147
Cooling 0.55 0.55 0.55 0.57 Cooling 0.55 0.55 0.55 0.57
Rated current A Rated current A
Heating 0.55 0.55 0.55 0.57 Heating 0.55 0.55 0.55 0.57

m3/h 650/570/500 800/600/500 800/600/500 800/600/500 m3/h 600/480/400 750/650/550 750/650/550 750/650/550
Airflow rate(H/M/L) Airflow rate(H/M/L)
CFM 383/335/294 471/353/294 471/353/294 471/353/294 CFM 353/283/235 441/383/324 441/383/324 441/383/324

Sound level dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 Sound level dB(A) 40/38/36 43/41/38 43/41/38 43/41/38

Type R410A Type R410A


Refrigerant Refrigerant
Control method EXV Control method EXV

Net dimension(W×H×D) mm 990x660x206 990x660x206 990x660x206 990x660x206 38-31/32x25-31/32x8-1/8


Net dimension(W×H×D) in.(mm)
Packing dimension(W×H×D) mm 1,089x744x296 1,089x744x296 1,089x744x296 1,089x744x296 (990x660x206)

Net weight kg 26 28 28 28 42-7/8x29-9/32x11-21/32


Packing dimension(W×H×D) in.(mm)
Gross weight kg 32 34 34 34 (1,089x744x296)
L(flare) mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Net/Gross weight lbs.(kg) 57.3/70.5(26/32) 61.7/75.0(28/34) 61.7/75.0(28/34) 61.7/75.0(28/34)
Piping
G(flare) mm Φ12.7 Φ12.7 Φ15.9 Φ15.9 L(flare) in.(mm) 1/4(Ф6.35) 1/4(Ф6.35) 3/8(Φ9.52) 3/8(Φ9.52)
connections Piping
Drain piping mm OD Ф16 OD Ф16 OD Ф16 OD Ф16 G(flare) in.(mm) 1/2(Φ12.7) 1/2(Φ12.7) 5/8(Φ15.9) 5/8(Φ15.9)
connections
Standard Controller Wireless remote controller (RM05/BG(T)E-A) Drain piping in.(mm) Φ5/8(Φ16) Φ5/8(Φ16) Φ5/8(Φ16) Φ5/8(Φ16)
-
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Model MDV-D80DL/N1-C MDV-D90DL/N1-C MDV-D112DL/N1-C MDV-D140DL/N1-C


Model MDV-D80DL/N1-C MDV-D90DL/N1-C MDV-D112DL/N1-C MDV-D140DL/N1-C
Power supply 1-phase, 220-240V, 50Hz
Power supply 220~240V-1Ph-60Hz
kW 8 9 11.2 14 14
kW 8 9 11.2
Cooling capacity kcal/h 6,800 7,700 9,600 12,000 12,000
Cooling capacity kcal/h 6,800 7,700 9,600
Btu/h 27,300 30,700 38,200 47,800 47,800
Btu/h 27,300 30,700 38,200
kW 9 10 12.5 15.5 15.5
kW 9 10 12.5
Heating capacity kcal/h 7,700 8,600 11,000 13,000 13,000
Heating capacity kcal/h 7,700 8,600 11,000
Btu/h 30,700 34,100 42,600 52,900 52,900
Btu/h 30,700 34,100 42,600
Cooling 130 130 182 182 241
Power input W Cooling 185 185 241
Heating 130 130 182 182 Power input W
Heating 185 185 241 241
Cooling 0.6 0.6 0.83 0.83 0.83
Rated current A Cooling 0.6 0.6 0.83
Heating 0.6 0.6 0.83 0.83 Rated current A
Heating 0.6 0.6 0.83 0.83
m3/h 1,200/900/700 1,200/900/700 1,980/1,860/1,730 1,980/1,860/1,730 1,980/1,860/1,730
Airflow rate(H/M/L) m3/h 1,200/900/700 1,200/900/700 1,980/1,860/1,730
CFM 706/530/412 706/530/412 1,165/1,095/1,018 1,165/1,095/1,018 Airflow rate(H/M/L)
CFM 706/530/412 706/530/412 1,165/1,095/1,018 1,165/1,095/1,018
Sound level dB(A) 45/43/40 45/43/40 47/45/42 47/45/42 47/45/42
Sound level dB(A) 45/43/40 45/43/40 47/45/42
Type R410A
Refrigerant Type R410A
Control method EXV Refrigerant
Control method EXV
Net dimension(W×H×D) mm 1,280x660x206 1,280x660x206 1,670x680x244 1,670x680x244
50-13/32x25-31/32x8-1/8 65-3/4x26-25/32x9-19/32
Packing dimension(W×H×D) mm 1,379x744x296 1,379x744x296 1,764x760x329 1,764x760x329 Net dimension(W×H×D) in.(mm)
(1,280 x 660x206) (1,670x680x244)
Net weight kg 34.5 34.5 54 54
54-9/32x29-9/32x11-21/32 69-29/64x29-59/64x12-61/64
Gross weight kg 41 41 59 59 Packing dimension(W×H×D) in.(mm)
(1,379x744x296) (1,764x760x329)
L(flare) mm Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Net/Gross weight lbs.(kg) 76.1/90.4(34.5/41) 76.1/90.4(34.5/41) 119.0/130.1(54/59) 119.0/130.1(54/59)
G(flare) mm Φ15.9 Φ15.9 Φ15.9 Φ15.9
connections L(flare) in.(mm) 3/8(Φ9.52) 3/8(Φ9.52) 3/8(Φ9.52) 3/8(Φ9.52)
Drain piping mm ODФ16 ODФ16 ODФ16 ODФ16 Piping
G(flare) in.(mm) 5/8(Φ15.9) 5/8(Φ15.9) 5/8(Φ15.9) 5/8(Φ15.9)
Standard Controller - Wireless remote controller (RM05/BG(T)E-A) connections
Drain piping in.(mm) OD Φ5/8(Φ16) OD Φ5/8(Φ16) OD Φ5/8(Φ16) OD Φ5/8(Φ16)

Notes: Standard Controller - Wireless remote controller (RM05/BG(T)E-A)


1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
Notes:
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
3. Floor standing :Sound level is measured 1m from air-outlet in horizontal distance, 1m above the floor in vertical distance.
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
Ceiling mounted:Sound level is measured 1m from air-outlet in horizontal distance,1m from air-outlet in vertical distance.
3. Floor standing :Sound level is measured 3.28ft.(1m) from air-outlet in horizontal distance, 3.28ft.(1m) above the floor in vertical distance.
* Specifications are subject to change without prior notice for product improvement. Ceiling mounted :Sound level is measured 3.28ft.(1m) from air-outlet in horizontal distance,3.28ft.(1m) from air-outlet in vertical distance.

* Specifications are subject to change without prior notice for product improvement.
41 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 42

Wall mounted(S type panel) Model

Power supply
MDV-D22G/N1-S MDV-D28G/N1-S MDV-D36G/N1-S

1-phase, 220-240V, 50Hz


MDV-D45G/N1-S MDV-D56G/N1-S

kW 2.2 2.8 3.6 4.5 5.6


Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Btu/h 7,500 9,500 12,200 15,300 19,100
kW 2.4 3.2 4 5 6.3
Heating capacity kcal/h 2,100 2,700 3,400 4,300 5,400
Btu/h 8,200 10,900 13,600 17,000 21,500
Cooling 28 28 28 45 45
Power input W
Heating 28 28 28 45 45
Cooling 0.14 0.14 0.14 0.2 0.2
Rated current A
Heating 0.14 0.14 0.14 0.2 0.2
m /h
3
525/480/430 525/480/430 590/520/480 860/755/630 925/860/755
Airflow rate(H/M/L)
CFM 309/283/253 309/283/253 309/283/253 506/444/371 544/506/444
Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34

Panel with LED display Refrigerant


Type R410A
Control method EXV

The front panel and display panel have different colors for choose: white and brown for big panel, blue Net dimension(W×H×D) mm 915×290×230 915×290×230 915 ×290×230 1,072×315×230 1,072×315×230

and brown for small panel, and the other colors can be customized according to the customers’ demands. Packing dimension(W×H×D) mm 1,020×390×315 1,020×390×315 1,020×390×315 1,180×415×315 1,180×415×315
Net weight kg 13 13 13 15.1 15.1
Gross weight kg 16.5 16.5 16.5 18.8 18.8
Convenient for installation Piping
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9
connections
Multi-refrigerant outlet pipe method: left\right\rear, more Drain piping mm ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5
flexible for installation. Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
The EXV is built-in the indoor unit, compact size, Longer
the connection pipe, Gas pipe: 468mm/Liquid pipe:
Rear
550mm, more flexible for the installation Model MDV-D22G/DN1-S MDV-D28G/DN1-S MDV-D36G/DN1-S MDV-D45G/DN1-S MDV-D56G/DN1-S
Left Right
Adopts new type fixing plate, easy for installation and stable.
Power supply 1-phase, 220-240V, 50Hz
kW 2.2 2.8 3.6 4.5 5.6
Auto swing louver Easy maintenance Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Btu/h 7,500 9,500 12,200 15,300 19,100
The Auto Swing Louver function Easy maintenance has been realized as the kW 5+0.9 6.3+0.9
2.4+0.75 3.2+0.75 4+0.75
ensures that the air direction front panel can removed for easy access. Heating capacity kcal/h 2,100+600 2,700+600 3,400+600 4,300+800 5,400+800
corresponds to the mode selected. Open panel Btu/h 8,200+2,600 10,900+2,600 13,600+2,600 17,000+3,100 21,500+3,100
Cooling 28 28 28 45 45
1 Power input W
Heating 28 28 28 45 45

Step 2 Cooling 0.14 0.14 0.14 0.2 0.2


Rated current A
Heating 0.14+3.38 0.14+3.38 0.14+3.38 0.20+4.05 0.20+4.05
Swing 3
m3/h 525/480/430 525/480/430 590/520/480 860/755/630 925/860/755
4 Airflow rate(H/M/L)
CFM 309/283/253 309/283/253 347/306/283 506/444/371 544/506/444
Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34
Type R410A
Refrigerant
Control method EXV
Net dimension(W×H×D) mm 915×290×230 915×290×230 915 ×290×230 1,072×315×230 1,072×315×230
Packing dimension(W×H×D) mm 1,020×390×315 1,020×390×315 1,020×390×315 1,180×415×315 1,180×415×315
Net weight kg 13 13 13 15.1 15.1
Gross weight kg 16.5 16.5 16.5 18.8 18.8
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping
G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9
connections
Drain piping mm ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured 1m below the air out-let both in horizontal and certical disscance.

* Specifications are subject to change without prior notice for product improvement.
43 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 44

Model MDV-D22G/N1-S MDV-D28G/N1-S MDV-D36G/N1-S MDV-D45G/N1-S MDV-D56G/N1-S Wall mounted(C type panel)
Power supply 220~240V-1Ph-60Hz
kW 2.2 2.8 3.6 4.5 5.6
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Btu/h 7,500 9,500 12,200 15,300 19,100
kW 2.4 3.2 4 5 6.3
Heating capacity kcal/h 2,100 2,700 3,400 4,300 5,400
Btu/h 8,200 10,900 13,600 17,000 21,500
Cooling 28 28 28 51 51
Power input W
Heating 28 28 28 51 51
Cooling 0.14 0.14 0.14 0.2 0.2
Rated current A
Heating 0.14 0.14 0.14 0.2 0.2
m3/h 525/480/430 525/480/430 590/520/480 860/755/630 925/860/755
Airflow rate(H/M/L)
CFM 309/283/253 309/283/253 347/306/283 506/444/371 544/506/444
Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34
Type R410A
Refrigerant
Control method EXV

Net dimension(W×H×D) in.(mm)


936-1/32x11-13/32x9-1/16 936-1/32x11-13/32x9-1/16
(915×290×230) (915×290×230)
36-1/32x11-13/32x9-1/16
(915×290×230)
42-7/32X12-13/32X9-1/16
(1,072×315×230)
42-7/32X12-13/32X9-1/16
(1,072×315×230)
Panel with LED display
40-5/32x15-11/32x12-13/32 40-5/32x15-11/32x12-13/32 40-5/32x15-11/32x12-13/32 46-15/32X16-11/32X12-13/32 46-15/32X16-11/32X12-13/32
Packing dimension(W×H×D) in.(mm)
(1,020×390×315) (1,020×390×315) (1,020×390×315) (1,180×415×315) (1,180×415×315)
The front panel and display panel have different colors for choose: white and brown for big panel, blue
Net weight lbs.(kg) 28.7(13) 28.7(13) 28.7(13) 33.4(15.1) 33.4(15.1) and brown for small panel, and the other colors can be customized according to the customers’ demands.
Gross weight lbs.(kg) 36.4(16.5) 36.4(16.5) 36.4(16.5) 41.5(18.8) 41.5(18.8)
L(flare) Ф1/4(Ф6.35)
Convenient for installation
in.(mm) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф3/8(Ф9.52)
Piping G(flare) in.(mm) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф5/8(Φ16)
connections Drain piping in.(mm) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5)
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
Multi-refrigerant outlet pipe method: left\right\rear, more
flexible for installation.
The EXV is built-in the indoor unit, compact size, Longer
the connection pipe, Gas pipe: 468mm/Liquid pipe:
Rear
Model MDV-D22G/DN1-S MDV-D28G/DN1-S MDV-D36G/DN1-S MDV-D45G/DN1-S MDV-D56G/DN1-S
550mm, more flexible for the installation
Left Right
Power supply 220~240V-1Ph-60Hz Adopts new type fixing plate, easy for installation and
kW 2.2 2.8 3.6 4.5 5.6
stable.
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Btu/h
kW
7,500
2.4+0.75
9,500
3.2+0.75
12,200
4+0.75
15,300
5+0.9
19,100
6.3+0.9
Auto swing louver Easy maintenance
Heating capacity kcal/h 2,100+600 2,700+600 3,400+600 4,300+800 5,400+800 The Auto Swing Louver Easy maintenance has been realized as
Btu/h 8,200+2,600 10,900+2,600 13,600+2,600 17,000+3,100 21,500+3,100
function ensures that the the front panel can removed for easy
Cooling 28 28 28 51 51
Power input
Heating
W
28 28 28 51 51 air direction corresponds to access.
Cooling 0.14 0.14 0.14 0.2 0.2 the mode selected. Open panel
Rated current A 1
Heating 0.14+3.38 0.14+3.38 0.14+3.38 0.20+4.05 0.20+4.05
m /h
3
525/480/430 525/480/430 590/520/480 860/755/630 925/860/755 2
Airflow rate(H/M/L)
CFM 309/283/253 309/283/253 347/306/283 506/444/371 544/506/444
Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34
Step 3

Refrigerant
Type R410A Swing 4

Control method EXV


936-1/32x11-13/32x9-1/16 936-1/32x11-13/32x9-1/16 36-1/32x11-13/32x9-1/16 42-7/32X12-13/32X9-1/16 42-7/32X12-13/32X9-1/16
Net dimension(W×H×D) in.(mm)

Low noise and improved flow control make more comfortable


(915×290×230) (915×290×230) (915×290×230) (1,072×315×230) (1,072×315×230)
40-5/32x15-11/32x12-13/32 40-5/32x15-11/32x12-13/32 40-5/32x15-11/32x12-13/32 46-15/32X16-11/32X12-13/32 46-15/32X16-11/32X12-13/32
Packing dimension(W×H×D) in.(mm)
(1,020×390×315) (1,020×390×315) (1,020×390×315) (1,180×415×315) (1,180×415×315)
Net weight lbs.(kg) 28.7(13) 28.7(13) 28.7(13) 33.4(15.1) 33.4(15.1) Adoption of the mechanical expansion valve which has
Gross weight lbs.(kg) 36.4(16.5) 36.4(16.5) 36.4(16.5) 41.5(18.8) 41.5(18.8) 2000 stages element positioning, ensure precise flow
L(flare) in.(mm) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф3/8(Ф9.52)
Piping
control, as well lower modulation noise when EXV
G(flare) in.(mm) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф5/8(Φ15.9)
connections Drain piping in.(mm) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5)
operating. Creates quiet and comfortable environment.
Standard Controller - Wireless remote controller (RM05/BG(T)E-A) Three air flow speed: high/middle/low, double air guides.
Notes:
Smoother airflow with less turbulence. Owing to the
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) multiple-blade fan and the air guide design, the airflow is
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) getting smoother and more comfortable.
3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.

* Specifications are subject to change without prior notice for product improvement.
45 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 46

Model MDV-D22G/N1YB MDV-D28G/N1YB MDV-D36G/N1YB MDV-D45G/N1YB MDV-D56G/N1YB Model MDV-D22G/N1YB MDV-D28G/N1YB MDV-D36G/N1YB MDV-D45G/N1YB MDV-D56G/N1YB

Power supply 220-240V~, 1Ph, 60Hz


Power supply 1-phase, 220-240V, 50Hz
kW 2.2 2.8 3.6 4.5 5.6
kW 2.2 2.8 3.6 4.5 5.6
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Btu/h 7,500 9,500 12,300 15,400 19,100
Btu/h 7,500 9,500 12,300 15,400 19,100
kW 2.4 3.2 4 5 6.3
kW 2.4 3.2 4 5 6.3 Heating capacity kcal/h 2,200 2,700 3,400 4,300 5,400
Heating capacity kcal/h 2,200 2,700 3,400 4,300 5,400 Btu/h 8,900 10,900 13,600 17,000 21,500
Btu/h 8,900 10,900 13,600 17,000 21,500 Cooling 28 28 28 45 45
Power input W
Cooling 28 28 28 45 45 Heating 28 28 28 45 45
Power input W
Heating 28 28 28 45 45 Cooling 0.14 0.14 0.14 0.2 0.2
Rated current A
Cooling 0.14 0.14 0.14 0.2 0.2 Heating 0.14 0.14 0.14 0.2 0.2
Rated current A
Heating 0.14 0.14 0.14 0.2 0.2 m3/h 557/520/467 557/520/467 557/520/467 842/722/597 842/722/597
Airflow rate(H/M/L)
m3/h 525/480/430 525/480/430 525/480/430 860/755/630 925/860/755 CFM 328/306/275 328/306/275 328/306/275 496/425/351 496/425/351
Airflow rate(H/M/L)
CFM 309/283/253 309/283/253 309/283/253 506/444/371 544/506/444 Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34

40/38/34 40/38/34 Type R410A


Sound level dB(A) 35/32/29 35/32/29 35/32/29 Refrigerant
Control method EXV
Type R410A
Refrigerant 36-1/32×11-13/32×8-9/32 36-1/32×11-13/32×8-9/32 36-1/32×11-13/32×8-9/32 42-7/32×12-13/32×8-9/32 42-7/32×12-13/32×8-9/32
Control method EXV Net dimension(W×H×D) in.(mm)
(915×290×210) (915×290×210) (915×290×210) (1,070×315×210) (1,070×315×210)
Net dimension(W×H×D) mm 915×290×210 915×290×210 915×290×210 1,070×315×210 1,070×315×210
40-5/32×15-5/32×11-13/16 40-5/32×15-5/32×11-13/16 40-5/32×15-5/32×11-13/16 45-7/8×15-9/16×11-7/32 45-7/8×15-9/16×11-7/32
Packing dimension(W×H×D) mm 1,020×385×300 1,020×385×300 1,020×385×300 1,165×395×285 1,165×395×285 Packing dimension(W×H×D) in.(mm)
(1,020×385×300) (1,020×385×300) (1,020×385×300) (1,165×395×285) (1,165×395×285)
Net weight kg 12 12 12 16 16
Net weight lbs.(kg) 26.5(12) 26.5(12) 26.5(12) 35.3(16) 35.3(16)
Gross weight kg 16 16 16 19 19
Gross weight lbs.(kg) 36.4(16) 36.4(16) 36.4(16) 41.9(19) 41.9(19)
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 L(flare) Ф1/4(Ф6.35)
Piping in.(mm) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф3/8(Ф9.52)
G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Piping G(flare) in.(mm) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф5/8(Φ15.9)
connections
Drain piping mm ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 connections Drain piping in.(mm) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5)
Standard Controller - Wireless remote controller (RM05/BG(T)E-A) Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Model MDV-D22G/DN1YB MDV-D28G/DN1YB MDV-D36G/DN1YB MDV-D45G/DN1YB MDV-D56G/DN1YB Model MDV-D22G/DN1YB MDV-D28G/DN1YB MDV-D36G/DN1YB MDV-D45G/DN1YB MDV-D56G/DN1YB

Power supply Power supply 220-240V~, 1Ph, 60Hz


1-phase, 220-240V, 50Hz
kW 2.2 2.8 3.6 4.5 5.6
kW 2.2 2.8 3.6 4.5 5.6
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800
Btu/h 7,500 9,500 12,300 15,400 19,100
Btu/h 7,500 9,500 12,300 15,400 19,100
kW 2.4+0.75 3.2+0.75 4+0.75 5+0.9 6.3+0.9
kW 2.4+0.75 3.2+0.75 4+0.75 5+0.9 6.3+0.9 Heating capacity kcal/h 2,200+600 2,700+600 3,400+600 4,300+800 5,400+800
Heating capacity kcal/h 2,200+600 2,700+600 3,400+600 4,300+800 5,400+800 Btu/h 8,900+2,500 10,900+2,500 13,600+2,500 17,000+3,100 21,500+3,100
Btu/h 8,900+2,500 10,900+2,500 13,600+2,500 17,000+3,100 21,500+3,100 Cooling 28 28 28 45 45
Power input W
Cooling 28 28 28 45 45 Heating 28 28 28 45 45
Power input W
Heating 28 28 28 45 45 Cooling 0.14 0.14 0.14 0.2 0.2
Rated current A
Cooling 0.14 0.14 0.14 0.2 0.2 Heating 0.14+3.38 0.14+3.38 0.14+3.38 0.2+4.05 0.2+4.25
Rated current A
Heating 0.14+3.38 0.14+3.38 0.14+3.38 0.2+4.05 0.2+4.25 m3/h 557/520/467 557/520/467 557/520/467 842/722/597 842/722/597
Airflow rate(H/M/L)
m3/h 525/480/430 525/480/430 525/480/430 860/755/630 925/860/755 CFM 328/306/275 328/306/275 328/306/275 496/425/351 496/425/351
Airflow rate(H/M/L) Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34
CFM 309/283/253 309/283/253 309/283/253 506/444/371 544/506/444
Type R410A
Sound level dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 Refrigerant
Control method EXV
Type R410A
Refrigerant 36-1/32×11-13/32×8-9/32 36-1/32×11-13/32×8-9/32 36-1/32×11-13/32×8-9/32 42-7/32×12-13/32×8-9/32 42-7/32×12-13/32×8-9/32
Control method EXV Net dimension(W×H×D) in.(mm)
(915×290×210) (915×290×210) (915×290×210) (1,070×315×210) (1,070×315×210)
Net dimension(W×H×D) mm 915×290×210 915×290×210 915×290×210 1,070×315×210 1,070×315×210
40-5/32×15-5/32×11-13/16 40-5/32×15-5/32×11-13/16 40-5/32×15-5/32×11-13/16 45-7/8×15-9/16×11-7/32 45-7/8×15-9/16×11-7/32
Packing dimension(W×H×D) in.(mm)
Packing dimension(W×H×D) mm 1,020×385×300 1,020×385×300 1,020×385×300 1,165×395×285 1,165×395×285 (1,020×385×300) (1,020×385×300) (1,020×385×300) (1,165×395×285) (1,165×395×285)
Net weight kg 12 12 12 16 16 Net weight lbs.(kg) 26.5(12) 26.5(12) 26.5(12) 35.3(16) 35.3(16)
Gross weight kg 16 16 16 19 19 Gross weight lbs.(kg) 36.4(16) 36.4(16) 36.4(16) 41.9(19) 41.9(19)
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 L(flare) in.(mm) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф3/8(Ф9.52)
Piping
G(flare) Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Piping G(flare) in.(mm) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф5/8(Φ15.9)
mm
connections connections
Drain piping ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 ODФ16.5 Drain piping in.(mm) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5) OD 21/32(Ф16.5)
mm
Standard Controller Wireless remote controller (RM05/BG(T)E-A) Standard Controller - Wireless remote controller (RM05/BG(T)E-A)
-

Notes: Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal) 1.Nominal cooling capacities are based on the following conditions: return air temp. : 80.6°CF(27°C)DB, 66.2°CF(19°C)WB, outdoor temp.:95°F(35°C)DB, equivalent ref. Piping: 26.25ft
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal) (8m) (horizontal)
3. Sound level is measured 1m below the air out-let both in horizontal and vertical distance. 2. Nominal heating capacities are based on the following conditions: return air temp.: 68°F(20°C)DB, outdoor temp.: 44.6°F(7°C)DB, 42.8°F(6°C)WB, equivalent ref. Piping: 26.25ft(8m)
(horizontal)
* Specifications are subject to change without prior notice for product improvement.
3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.
47 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 48

Floor Standing
MDV-D22Z/N1-F1B MDV-D28Z/N1-F1B MDV-D36Z/N1-F1B MDV-D45Z/N1-F1B MDV-D56Z/N1-F1B MDV-D71Z/N1-F1B MDV-D80Z/N1-F1B

MDV-D22Z/N1-F2B MDV-D28Z/N1-F2B MDV-D36Z/N1-F2B MDV-D45Z/N1-F2B MDV-D56Z/N1-F2B MDV-D71Z/N1-F2B MDV-D80Z/N1-F2B

MDV-D22Z/N1-F3B MDV-D28Z/N1-F3B MDV-D36Z/N1-F3B MDV-D45Z/N1-F3B MDV-D56Z/N1-F3B MDV-D71Z/N1-F3B MDV-D80Z/N1-F3B


Model
MDV-D22Z/N1-F4 MDV-D28Z/N1-F4 MDV-D36Z/N1-F4 MDV-D45Z/N1-F4 MDV-D56Z/N1-F4 MDV-D71Z/N1-F4 MDV-D80Z/N1-F4

MDV-D22Z/N1-F5 MDV-D28Z/N1-F5 MDV-D36Z/N1-F5 MDV-D45Z/N1-F5 MDV-D56Z/N1-F5 MDV-D71Z/N1-F5 MDV-D80Z/N1-F5

Power supply 1-phase, 220-240V, 50Hz


kW 2.2 2.8 3.6 4.5 5.6 7.1 8
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800 6,100 6,900
Btu/h 7,500 9,500 12,200 15,300 19,100 242,00 27,300
kW 2.4 3.2 4 5 6.3 8 9
Heating capacity kcal/h 2,100 2,700 3,400 4,300 5,400 6,900 7,700
Btu/h 8,200 10,900 13,600 17,000 21,500 27,300 30,700
Cooling 40 46 40 49 88 130 130
Power input W
Heating 40 46 35 49 88 130 130

Cooling 0.19 0.2 0.19 0.22 0.38 0.57 0.57


Rated current A
Heating 0.19 0.2 0.15 0.22 0.38 0.57 0.57
m3/h 530/456/400 569/485/421 624/522/375 660/542/440 1,150/970/830 1,380/1,100/870 1,332/1,212/1,023
Airflow rate(H/M/L)
CFM 312/268/235 335/285/248 367/307/221 388/319/259 677/571/489 812/647/512 784/713/602
F1B 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
Exposed version with air Exposed version with air F2B 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
Sound
intake from front(F1 series) intake from below(F2 series) level(Hi/Mid/Lo) F3B
dB(A)
36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
F4 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33

Easy installation F5 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33


Type R410A
Refrigerant
Floor standing types can be hung on the wall or installed on the floor. The former can make cleaning and Control method EXV
F1B 1,000×220×625 1,000×220×625 1,200×220×625 1,200×220×625 1,500×220×625 1,500×220×625 1,500×220×625
maintenance much more easily. Running the piping from the back allows the unit to be hung on walls.
F2B 1,000×220×625 1,000×220×625 1,200×220×625 1,200×220×625 1,500×220×625 1,500×220×625 1,500×220×625
Cleaning under the unit, where dust tends to accumulate, is considerably easier. Net dimension
(W×H×D) F3B mm 840×212×545 840×212×545 1,036×212×545 1,036×212×545 1,336×212×545 1,336×212×545 1,336×212×545

F4 1,000×220×625 1,000×220×625 1,200×220×625 1,200×220×625 1,500×220×625 1,500×220×625 1,500×220×625


Easy maintenance F5 1,000×220×625 1,000×220×625 1,200×220×625 1,200×220×625 1,500×220×625 1,500×220×625 1,500×220×625

F1B 1,089×312×722 1,089×312×722 1,289×312×722 1,289×312×722 1,589×312×722 1,589×312×722 1,589×312×722


Filter is equipped as standard accessory, and it can be removed and cleaned easily due to Midea’s F2B 1182×312×722 1,182×312×722 1,382×312×722 1,289×312×722 1,682×312×722 1,682×312×722 1,682×312×722
Packing
sophisticated design as well as the removable blades. dimension F3B mm 925×305×639 925×305×639 1,125×305×639 1,125×305×639 1,425×305×639 1,425×305×639 1,425×305×639
(W×H×D)
F4 1,089×312×722 1,089×312×722 1,289×312×722 1,289×312×722 1,589×312×722 1,589×312×722 1,589×312×722
Streamlined appearance makes it much more harmonious with the decoration. All metal parts are made of
F5 1,182×312×722 1,182×312×722 1,382×312×722 1,382×312×722 1,682×312×722 1,682×312×722 1,682×312×722
commercial grade galvanized steel, providing maximum protection against corrosion.
F1B 30/35 30/35 37/43 37/43 44/50 44/50 44/50

F2B 30/38 30/38 37/46 37/46 44/53 44/53 44/53

So compact that it fits into even a tiny space Net/Gross


weight
F3B kg 26/29.5 26/29.5 29.5/34 29.5/34 36/40 36/40 36/40

F4 30/35 30/35 37/43 37/43 44/50 44/50 44/50

F5 30/38 30/38 37/46 37/46 44/53 44/53 44/53


Concealed floor standing type The body is concealed in the skirting-wall to pursue harmony with
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52
the interior. With 212mm depth of body dimension, it can be Piping
G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.9 Φ15.9 Φ15.9
connections
installed in the perimeter zone. Drain piping ODФ16 ODФ16 ODФ16 ODФ16 ODФ16 ODФ16 ODФ16
mm
Low noise level due to special installation method for not exposed Standard Controller Wireless remote controller (RM05/BG(T)E-A)
in the room space.
NEW
NEW panel design
panel design
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance.

* Specifications are subject to change without prior notice for product improvement.

F3 series concealed type Air intake from front(F4 series) Air intake from below(F5 series)
49 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 50

Console
MDV-D22Z/N1-F1B MDV-D28Z/N1-F1B MDV-D36Z/N1-F1B MDV-D45Z/N1-F1B MDV-D56Z/N1-F1B MDV-D71Z/N1-F1B MDV-D80Z/N1-F1B

MDV-D22Z/N1-F2B MDV-D28Z/N1-F2B MDV-D36Z/N1-F2B MDV-D45Z/N1-F2B MDV-D56Z/N1-F2B MDV-D71Z/N1-F2B MDV-D80Z/N1-F2B

MDV-D22Z/N1-F3B MDV-D28Z/N1-F3B MDV-D36Z/N1-F3B MDV-D45Z/N1-F3B MDV-D56Z/N1-F3B MDV-D71Z/N1-F3B MDV-D80Z/N1-F3B


Model
MDV-D22Z/N1-F4 MDV-D28Z/N1-F4 MDV-D36Z/N1-F4 MDV-D45Z/N1-F4 MDV-D56Z/N1-F4 MDV-D71Z/N1-F4 MDV-D80Z/N1-F4

MDV-D22Z/N1-F5 MDV-D28Z/N1-F5 MDV-D36Z/N1-F5 MDV-D45Z/N1-F5 MDV-D56Z/N1-F5 MDV-D71Z/N1-F5 MDV-D80Z/N1-F5

Power supply 220-240V,1Ph, 60Hz


kW 2.2 2.8 3.6 4.5 5.6 7.1 8
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 4,800 6,100 6,900
Btu/h 7,500 9,500 12,200 15,300 19,100 24,200 27,300
kW 2.4 3.2 4 5 6.3 8 9
Heating capacity kcal/h 2,100 2700 3,400 4,300 5,400 6900 7,700
Btu/h 8,200 10,900 13,600 17,000 21,500 27,300 30,700
Cooling 40 46 50 55 88 130 130
Power input W
Heating 40 46 35 55 88 130 130

Cooling 0.19 0.2 0.19 0.22 0.38 0.57 0.57


Rated current A
Heating 0.19 0.2 0.15 0.22 0.38 0.57 0.57
m /h 569/485/421 624/522/375
Compact unit body, space saving, nice-looking appearance
3
530/456/400 660/542/440 1,150/970/830 1,380/1,100/870 1,332/1,212/1,023
Airflow rate(H/M/L)
CFM 312/268/235 335/285/248 367/307/221 388/319/259 677/571/489 812/647/512 784/713/602
F1B 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33 This unit body is very thin and harmonious with room. It is elegant and space saving.
F2B 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
Sound The EXV is fixed inside of the indoor unit, Compact unit body.
dB(A)
level(Hi/Mid/Lo) F3B 36/33/29 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 44/39/33
F4
F5
36/33/29
36/33/29
36/33/29
36/33/29
37/34/30
37/34/30
37/34/30
37/34/30
41/35/31
41/35/31
44/39/33
44/39/33
44/39/33
44/39/33
Flexible installation.
Type R410A
Refrigerant Can be used for floor standing or lower wall plications
Control method EXV

F1B
47-1/4×24-19/32×8-21/32 47-1/4×24-19/32×8-21/32 47-1/4×24-19/32×8-21/32 47-1/4×24-19/32×8-21/32 59-1/16×24-19/32×8-21/32( 59-1/16×24-19/32×8-21/32( 59-1/16×24-19/32×8-21/32( As a floor standing type, it can be semi or fully cessed
(1,200×625×220) (1,200×625×220) (1,200×625×220) (1,200×625×220) 1,500×625×220) 1,500×625×220) 1,500×625×220)
F2B
47-1/4×24-19/32×8-21/32 47-1/4×24-19/32×8-21/32 47-1/4×24-19/32×8-21/32 47-1/4×24-19/32×8-21/32 59-1/16×24-19/32×8-21/32( 59-1/16×24-19/32×8-21/32( 59-1/16×24-19/32×8-21/32 without loss of capacity.
(1,200×625×220) (1,200×625×220) (1,200×625×220) (1,200×625×220) 1,500×625×220) 1,500×625×220) (1,500×625×220)
Net dimension 40-25/32×21-15/32×8-11/32 40-25/32×21-15/32×8-11/32 40-25/32×21-15/32×8-11/32 40-25/32×21-15/32×8-11/32 52-19/32×21-15/32×8-11/32 52-19/32×21-15/32×8-11/32 52-19/32×21-15/32×8-11/32
F3B in.(mm)
(W×H×D) (1,036×545×212) (1,036×545×212) (1,036×545×212) (1,036×545×212) (1,336×545×212) (1,336×545×212) (1,336×545×212)
47-1/4x24-19/32x8-21/32 47-1/4x24-19/32x8-21/32 47-1/4x24-19/32x8-21/32 47-1/4x24-19/32x8-21/32 59-1/16x24-19/32x8-21/32( 59-1/16x24-19/32x8-21/32( 59-1/16x24-19/32x8-21/32
F4

F5
(1,200×625×220)
47-1/4x24-19/32x8-21/32
(1,200×625×220)
47-1/4x24-19/32x8-21/32
(1,200×625×220)
47-1/4x24-19/32x8-21/32
(1,200×625×220)
47-1/4x24-19/32x8-21/32
1,500×625×220)
59-1/16x24-19/32x8-21/32(
1,500×625×220)
59-1/16x24-19/32x8-21/32(
(1,500×625×220)
59-1/16x24-19/32x8-21/32 High comfort
(1,200×625×220) (1,200×625×220) (1,200×625×220) (1,200×625×220) 1,500×625×220) 1,500×625×220) (1,500×625×220)
50-3/4x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 62-9/16x28-7/16x12-9/32 62-9/16x28-7/16x12-9/32 62-9/16x28-7/16x12-9/32
F1B
(1,289×722×312) (1,289×722×312) (1,289×722×312) (1,289×722×312) (1,589×722×312) (1,589×722×312) (1,589×722×312) Flexible air blow: vertical auto swing and wide angle louvers ensure that warm air reaches the furthest
F2B
46-17/32x28-7/16x12-9/32 46-17/32x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 66-7/32x28-7/16x12-9/32 66-7/32x28-7/16x12-9/32 66-7/32x28-7/16x12-9/32 corners of the room and increase the air flow coverage
(1,382×722×312) (1,382×722×312) (1,289×722×312) (1,289×722×312) (1,682×722×312) (1,682×722×312) (1,682×722×312)
Packing
dimension F3B in.(mm) 44-9/32x25-5/32x12-1/64 44-9/32x25-5/32x12-1/64 44-9/32x25-5/32x12-1/64 44-9/32x25-5/32x12-1/64 56-3/32x25-5/32x12-1/64 56-3/32x25-5/32x12-1/64 56-3/32x25-5/32x12-1/64 Indoor unit adopts DC motor which has five level fan speed meet different requirements.
(1,125×639×305) (1,125×639×305) (1,125×639×305) (1,125×639×305) (1,425×639×305) (1,425×639×305) (1,425×639×305)
(W×H×D)
50-3/4x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 50-3/4x28-7/16x12-9/32 62-9/16x28-7/16x12-9/32 62-9/16x28-7/16x12-9/32 62-9/16x28-7/16x12-9/32 Adoption of the Fujikoki brand mechanical expansion valve which has 2000 stages element positioning,
F4
(1,289×722×312) (1,289×722×312) (1,289×722×312) (1,289×722×312) (1,589×722×312) (1,589×722×312) (1,589×722×312)
46-17/32x28-7/16x12-9/32 46-17/32x28-7/16x12-9/32 54-13/32x28-7/16x12-9/32( 54-13/32x28-7/16x12-9/32( 66-7/32x28-7/16x12-9/32 66-7/32x28-7/16x12-9/32 66-7/32x28-7/16x12-9/32 ensure precise flow control, as well lower modulation noise when EXV operating.
F5
(1,382×722×312) (1,382×722×312) 1,382×722×312) 1,382×722×312) (1,682×722×312) (1,682×722×312) (1,682×722×312)
F1B 66.2/77.2(30/35) 66.2/77.2(30/35) 82/95(37/43) 82/95(37/43) 97/110.3(44/50) 97/110.3(44/50) 97/110.3(44/50)

Powerful mode can be selected for rapid cooling or heating.


F2B 66.2/84(30/38) 66.2/84(30/38) 82/101.5(37/46) 82/101.5(37/46) 97/117(44/53) 97/117(44/53) 97/117(44/53)

Net/Gross F3B lbs.(kg) 57.4/65(26/29.5) 57.4/65(26/29.5) 65/75(29.5/34) 65/75(29.5/34) 79.4/88.3(36/40) 79.4/88.3(36/40) 79.4/88.3(36/40)

weight F4 66.2/77.2(30/35) 66.2/77.2(30/35) 82/95(37/43) 82/95(37/43) 97/110.3(44/50) 97/110.3(44/50) 97/110.3(44/50)


F5 66.2/84(30/38) 66.2/84(30/38) 82/101.5(37/46) 82/101.5(37/46) 97/117(44/53) 97/117(44/53) 97/117(44/53) COOLING MODE HEATING MODE
L(flare) in.(mm) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф3/8, (Ф9.52) Ф3/8, (Ф9.52) Ф3/8, (Ф9.52)
Piping in.(mm)
G(flare) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф1/2(Φ12.7) Ф5/8(Φ15.9) Ф5/8(Φ15.9) Ф5/8(Φ15.9)
connections
Drain piping in.(mm) OD 5/8(Ф16) OD 5/8(Ф16) OD 5/8(Ф16) OD 5/8(Ф16) OD 5/8(Ф16) OD 5/8(Ф16) OD 5/8(Ф16)
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Notes:
1.Nominal cooling capacities are based on the following conditions: return air temp. : 80.6°CF(27°C)DB, 66.2°CF(19°C)WB, outdoor temp.:95°F(35°C)DB,
equivalent ref. Piping: 26.25ft(8m)(horizontal)
2.Nominal heating capacities are based on the following conditions: return air temp.: 68°F(20°C)DB, outdoor temp.: 44.6°F(7°C)DB, 42.8°F(6°C)WB,
equivalent ref. Piping: 26.25ft(8m)(horizontal) quick cooling to maintain temp anti-cold air normal operation
3.Sound level is measured 3.28ft.(1m) from the air out-let in horizontal distance and 3.28ft.(1m) above the floor in vertical distance.
51 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 52

High efficiency filter Model MDV-D22Z/DN1-B MDV-D28Z/DN1-B MDV-D36Z/DN1-B MDV-D45Z/DN1-B

Power supply 220-240V~, 1Ph, 60Hz


Built in Formaldehyde nemesis filter kW 2.2 2.8 3.6 4.5
Active-carbon and biological anti-virus filter is optional. Cooling capacity kcal/h 1,900 2,400 3,100 3,900
Btu/h 7,500 9,500 12,200 15,300

Two air outlet, four air inlet Quiet design Heating capacity
kW
kcal/h
2.6
2,200
3.2
2,700
4.0
3,400
5.0
4,300
Btu/h 8,900 10,900 13,600 17,000
Air inlet from 4 directions, there are 2 optional Five speeds indoor unit, Low noise and Energy Cooling 20 25 25 45
Power input W
air-outlet ways, Both up and Down air-outlet or up saving. Heating 20 25 25 45
air-outlet only. Cooling 0.09 0.11 0.11 0.2
Rated current A
Heating 0.09 0.11 0.11 0.2
m3/h 468/450/395 468/450/395 467/427/395 540/481/421
Airflow rate(H/M/L)
CFM 275/265/232 275/265/232 275/251/232 318/283/248
Air Outlet
Sound level dB(A) 38/32/26 39/33/27 39/33/27 42/39/36
Type R410A
Refrigerant
Control method EXV
Net dimension(W×H×D) in.(mm) 27-9/16×23-5/8×8-9/32 (700×600×210)
Packing dimension(W×H×D) in.(mm) 31-7/8×27-15/16×12 (810×710×305)
Net weight lbs.(kg) 30.9(14) 33(15) 33(15) 33(15)

Air Inlet Gross weight lbs.(kg) 42.9(19) 44.1(20) 44.1(20) 44.1(20)


L(flare) in.(mm) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35) Ф1/4(Ф6.35)
Piping
Bottom, Top, and right/left side, for better ventilation. Low noise operation, lowest to 26dB(A) connections
G(flare) in.(mm) Ф1/2(Ф12.7) Ф1/2(Ф12.7) Ф1/2(Ф12.7) Ф1/2(Ф12.7)
Drain piping in.(mm) OD 5/8(Ф16) OD 5/8(Ф16) OD 5/8(Ф16) OD 5/8(Ф16)
Standard Controller - Wireless remote controller (RM05/BG(T)E-A)

Model MDV-D22Z/DN1-B MDV-D28Z/DN1-B MDV-D36Z/DN1-B MDV-D45Z/DN1-B Notes:


1.Nominal cooling capacities are based on the following conditions: return air temp. : 80.6°CF(27°C)DB, 66.2°CF(19°C)WB,
Power supply 1-phase, 220-240V, 50Hz
outdoor temp.:95°F(35°C)DB, equivalent ref. Piping: 26.25ft(8m)(horizontal)
kW 2.2 2.8 3.6 4.5
2.Nominal heating capacities are based on the following conditions: return air temp.: 68°F(20°C)DB,
Cooling capacity kcal/h 1,900 2,400 3,100 3,900 outdoor temp.: 44.6°F(7°C)DB, 42.8°F(6°C)WB, equivalent ref. Piping: 26.25ft(8m)(horizontal)
Btu/h 7,500 9,500 12,200 15,300 3.Sound level is measured 3.28ft.(1m) from the air out-let in horizontal distance and 3.28ft.(1m) above the floor in vertical distance
kW 2.6 3.2 4.0 5.0
Heating capacity kcal/h 2,200 2,700 3,400 4,300
Btu/h 8,900 10,900 13,600 17,000
Cooling 20 25 25 45
Power input W
Heating 20 25 25 45
Cooling 0.09 0.11 0.11 0.2
Rated current A
Heating 0.09 0.11 0.11 0.2
m3/h 430/345/229 510/430/229 510/430/229 660/512/400
Airflow rate(H/M/L)
CFM 253/203/135 300/253/135 300/253/135 388/300/235
Sound level dB(A) 38/32/26 39/33/27 39/33/27 42/39/36
Type R410A
Refrigerant
Control method EXV
Net dimension(W×H×D) mm 700×600×210 700×600×210 700×600×210 700×600×210
Packing dimension(W×H×D) mm 810×710×305 810×710×305 810×710×305 810×710×305
Net weight kg 14 15 15 15
Gross weight kg 19 20 20 20
L(flare) mm Φ6.35 Φ6.35 Φ6.35 Φ6.35
Piping G(flare) mm Φ12.7 Φ12.7 Φ12.7 Φ12.7
connections Drain piping - OD Ф16 OD Ф16 OD Ф16 OD Ф16
Standard Controller Wireless remote controller (RM05/BG(T)E-A)

Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB, and equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured 1m from the air out-let in horizontal distance and 1m above the floor in vertical distance.

* Specifications are subject to change without prior notice for product improvement.
53 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 54

Model MDV-D125T1/N1-FA MDV-D140T1/N1-FA

Fresh Air Processing Unit Power Supply

kW 12.5
1-phase, 220-240V, 50Hz

14

Cooling kcal/h 10,766 12,057

btu/h 42,600 47,800


Capacity
kW 10.5 12
Heating kcal/h 9,043 10,335

btu/h 35,800 41,000

Input W 461 461


Power (Cooling)
Rated Current A 2.3 2.3

Input W 461 461


Power (Heating)
Rated Current A 2.3 2.3

m3/h 1,700/1,350/1,050 1,700/1,350/1,050


Air flow (H/M/L)
cfm 1,000/795/618 1,000/795/618

ESP (external static pressure) Pa 50(30~220) 50(30~220)

Sound Pressure (Hi/Mid/Lo) dB(A) 54/52/50 54/52/50

Type R410A
Refrigerant
Control Method EXV
Net dimension W×H×D mm 1,200×400×600 1,200×400×600

Packing dimension W×H×D mm 1,430×450×768 1,430×450×768

Creating comfortable and healthier climate Net/Gross Weight kg

mm
69.5/76 69.5/76

Liquid (Flare) Φ9.52 Φ9.52

Piping Connections Gas (Flare) mm Φ15.9 Φ15.9


Fresh air are introduced into the environment, improved air quality Create comfortable and healthier climate mm
Drain piping OD Ф25 OD Ф25
Drain pump pumphead mm 750

100% fresh air processing unit Standard Controller - Wire controller KJR-12B/DP(T)-E (6m wrie is standard)

the longest distance


of air supply is 14m Both fresh air filtration and heating/cooling can be
Fresh air in take
achieved in a single system. Model MDV-D125T1/VN1-FA MDV-D140T1/VN1-FA

Indoor units and fresh air processing unit can be Power Supply 220~240V-1Ph-60Hz

connected to the same refrigerant system, resulting in kW 12.5 14


INDOOR UNIT Cooling kcal/h 10,766 12,057
enhanced design flexibility and a significant reduction in
The height of air btu/h 42,600 47,800
Air supply Air return
supply is 6.5m total system costs. Capacity
kW 10.5 12
Heating kcal/h 9,043 10,335

btu/h 35,800 41,000

High external static pressure Power (Cooling)


Input W 468 468

Rated Current A 2.3 2.7

External static pressure can be up to 220Pa for more flexible duct applications. Power (Heating)
Input W 468 468

Rated Current A 2.3 2.7


The maximal distance of air supply is about 14m and the maximum height of air supply is about 6.5m. m3/h 1,568/1,452/1,352 1,568/1,452/1,352
Indoor air flow (H/M/L)
cfm 923/855/796 923/855/796

Innovative air supply technology for excellent room temperature control ESP (external static pressure) Pa 50(30~ 196) 50(30~ 196)

Sound Pressure (Hi/Mid/Lo) dB(A) 55/53/50 55/52/49

Layout Example: Refrigerant


Type

Control Method
R410A
EXV
Net dimension 47-1/4×15-3/4×23-5/8 47-1/4×15-3/4×23-5/8
Outdoor Units W×H×D in.(mm)
(1,200×400×600) (1,200×400×600)

56-5/16×17-23/32×30-1/4 56-5/16×17-23/32×30-1/4
Packing dimension W×H×D in.(mm)
(1,430×450×768) (1,430×450×768)
Net/Gross Weight lbs.(kg) 153.2/167.5(69.5/76) 153.2/167.5(69.5/76)

Liquid (Flare) in.(mm) Φ3/8(Φ9.52) Φ3/8(Φ9.52)


Indoor Unit Indoor Unit
Piping Connections Gas (Flare) in.(mm) Φ5/8(Φ15.9) Φ5/8(Φ15.9)

Drain piping in.(mm) OD 1-9/32(Ф32)ID 1(Ф25) OD 1-9/32(Ф32)ID 1(Ф25)


Outdoor Air processing unit
Standard Controller - Wire controller KJR-12B/DP(T)-E (6m wrie is standard)

Notes:
Air-conditioning Outsideair supply 1 .Nominal cooling capacities are based on the following conditions: outdoor air temp.: 33ºC DB, 24ºC WB, equivalent ref. piping: 8m (horizontal)
2. Nominal heating capacities are based on the following conditions: outdoor air temp.: 0°CDB, -1°CWB, equivalent ref. Piping: 8m (horizontal)
3. Sound level is measured 4.59ft.(1.4m) from the air out-let.

* external static pressure are based on high speed indoor air flow.

* Specifications are subject to change without prior notice for product improvement.

* One Mini VRF outdoor unit can only be connected with one air processing unit,and its capacity can not be overloaded.
55 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 56

OUTDOOR UNITS LINEUP - Mini VRF


Capacity 8kW~16kW(3PH~6PH)

NEW
Fashion
Design

Outdoor Units Mdodel MDV-V80W/DN1 MDV-V100W/DN1 MDV-V120W/DN1 MDV-V140W/DN1 MDV-V160W/DN1

Cooling Capacity kW 8 10 12 14 15.5


Cooling Input Power kW 2.05 2.68 3.25 3.95 4.52
Heating Capacity kW 9 11.5 13.2 15.4 17
Heating Input Power kW 2.24 2.9 3.47 4.16 4.77
Operating Range-Cooling °C (-15~48) (-15~48) (-15~48) (-15~48) (-15~48)
Operating Range-Heating °C (-15~27) (-15~27) (-15~27) (-15~27) (-15~27)
Power V-ph-Hz 220~240V-1PH-50Hz 220~240V-1PH-50Hz 220~240V-1PH-50Hz 220~240V-1PH-50Hz 220~240V-1PH-50Hz
Noise Level dB(A) 57.5 62.1 56.2 56.8 56.8
Airflow m³/h 3,600 5,100 6,000 6,000 6,000
Vertical Pipe Length m 20 20 20 20 20
Actual Pipe Length m 45 45 45 45 45
Equivalent Pipe Length m 50 50 50 50 50
Total Pipe Length m 100 100 100 100 100
Max.No.of indoor units 4 5 6 6 7
Connection Ratio % 45%-130% 45%-130% 45%-130% 45%-130% 45%-130%
Net Weight kg 62.4 72.4 95 95 95
Gross weight kg 66.8 81.7 106 106 106
Net Dimension(W×H×D) mm 975×862×355 1,075×966×396 900×1,327×320 900×1,327×320 900×1,327×320
Packing Dimension(W×H×D) mm 1,025×910×410 1,105×1,005×435 1,030×1,456×435 1,030×1,456×435 1,030×1,456×435

Mdodel MDV-V120W/DRN1 MDV-V140W/DRN1 MDV-V160W/DRN1 MDV-V120W/DVN1 MDV-V140W/DVN1

Cooling Capacity kW 12 14 16 12 14
Cooling Input Power kW 3.26 3.98 4.58 3.28 3.95
Heating Capacity kW 13.2 15.4 17 13.2 15.4
Heating Input Power kW 3.48 4.20 4.79 3.45 4.18
Operating Range-Cooling °C (-15~48) (-15~48) (-15~48) (-15~48) (-15~48)
Operating Range-Heating °C (-15~27) (-15~27) (-15~27) (-15~27) (-15~27)
Power V-ph-Hz 380~415V-3PH-50Hz 380~415V-3PH-50Hz 380~415V-3PH-50Hz 208~230V-1PH-60Hz 208~230V-1PH-60Hz
Noise Level dB(A) 57.5 57 58 58.0 57.3
Airflow m³/h 6,000 6,000 6,000 6,000 6,000
Vertical Pipe Length m 20 20 20 20 20
Actual Pipe Length m 45 45 60 45 45
Equivalent Pipe Length m 50 50 70 50 50
Total Pipe Length m 100 100 100 100 100
Max.No.of indoor units 6 6 7 6 6
Connection Ratio % 45%-130% 45%-130% 45%-130% 45%-130% 45%-130%
Net Weight kg 95 95 102 95 95
Gross weight kg 106 106 113 106 106
Net Dimension(W×H×D) mm 900×1,327×320 900×1,327×320 900×1,327×320 900×1,327×320 900×1,327×320
Packing Dimension(W×H×D) mm 1,030×1,456×435 1,030×1,456×435 1,030×1,456×435 1,030×1,456×435 1,030×1,456×435

Notes:
1. The cooling conditions: indoor temp.: 27℃DB(80.6℉), 19℃WB(60℉) outdoor temp.: 35℃DB(95℉) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20℃DB(68℉), 15℃WB(44.6℉) outdoor temp.: 7℃DB(42.8℉) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 3.28ft.(1 m) in front of the unit at a height of *m (2.95ft.(0.9m) for 80 model,3.28ft.(1m) for 100 model,3.94ft.(1.2m)
for 120~160 model)above the floor. During actual operation. These values are normally somewhat higher as a result of ambient conditions.
4. The above data may be changed without any notice for future improvement on quality and performance.
57 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 58

Control Systems Comparison of Controllers


Building Management System Centralized 3rd-generation
Item Remote Wired Controller
Controller Monitoring System

Midea Remote User’s Monitoring


Service Centre System Connectable to various scales BMS/BAS RM05
KJR-10B
MD-CCM03
R06 MD-CCM09
Model name KJR-12B MDV-WLJKXT
R05 KJR-90B
KJR-90A
R51 KJRF-180A

MAX. controllable IDU 1 1 16/64 1024

On/Off

Operation mode setting

Midea Router Heating mode

MD-CCM08 Fan speed setting

Room temp. setting


AC control
function
MD-CCM07 Vertical swing

Centralized Control Horizontal swing

Indoor Centralized Weekly Schedule Network Monitoring Economic mode


Controller Centralized Controller Controller
Group setting

Key lock

MD-CCM03 MD-CCM09 Backlight

Current time

Display RC prohibition
Accessories Individual control
Address
Wire controller
Error code
KJR-10B
KJR-12B
KJR-90A Period /Week
Card-key MD-NIM05
Remote controller
On/Off per day /4
RM05 Timer
R05 On/Off per week /28
R06
R11
On/Off timer
R71
MD-NIM09 INFARED SENSOR R51
FOLLOW ME

Emergent stop

Emergent start
Control
Address setting
MD-NIM01
BMS access

Control via internet

: Each of this kind of controller has the corresponding functions.


: This function is optional.
: This function is not available through the corresponding controller.
Note: The wires in the diagram show the signal flows only, while not represent the actual connecting ways.
59 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 60

Wireless Remote Controller Wired Controller

RM02 RM05 R05 R06 R51 R71 KJR-10B KJR-12B KJR-90A

Functions Functions

Portable device Explicit user interface Follow me


Wireless remote controller is a portable control Users can synchronize the air conditioners’ With the FOLLOW ME function, the wired controller
device. It provides a convenient way for users to parameters with the display panel of the wireless
Sensor part can detect the air temperature at the user’s altitude
control the AC everywhere within a range up to remote controller. It’s the very way to make the room
instead that of the ceiling or the floor. This helps
11m. environment precisely work at the user’s will.
making the room environment comfortable and the
Temp 1
temperature accurate.
Transmitting display 2 3 ON/OFF
FOLLOW ME Button
Running mode 4

5 Time

6 Lock

ON OFF
7 Time ON/OFF Built-in timer
Economic operation 8
Fan speed
9 Built-in daily timer offers the convenience of
automatically starting and turning down the air ON 24°C OFF
conditioners according to the set time.
Background light 0 3 6 9 12 15 18 21 Time
The inddor unit is set to work at automode from 8:00 to 20:00
Background light allows user operate the device in
the dark room freely. The device lights whenever Easy connection Easy installation
the keys are pressed and last during the whole Wired controller conveniently connects to the indoor The wired controller allows to be installed into the
operating procedure. unit’s display panel with the appropriative connecting wall by fixing the bottom directly or fixing the device to
wire. a mounting cabinet.

Built-in timer
Built-in daily timer offers the convenience of Display panel KJR-10B
Wire controller
automatically starting and turning down the air ON 24°C OFF
conditioners according to the set time. 0 3 6 9 12 15 18 21 Time

Addressing setting The inddor unit is set to work at automode from 8:00 to 20:00
Indoor main board
Besides the machine’s auto assigning addresses
function, users can set the indoor unit’s address via
the wireless remote controller.

Specifications Specifications
Model RM02 RM05 R05 R06 R51 R71 Model 10B 12B 90A

Dimensions 150×60×15 150×65×20 150×65×20 100×55×20 140×60×15 125×42×27 Dimensions 120×120×15 120×120×15 90×86×13

Power 1.5V(LR03/AAA)×2 Power Power from the display panel. Extra power is unnecessary.
61 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 62

Centralized Controller Centralized Controller

INDOOR CENTRALIZED CONTROLLER WEEKLY SCHEDULE CENTRALIZED


MD-CCM03 CONTROLLER
MD-CCM09

Functions Functions
Centralized control Three lock modes Weekly schedule
MD-CCM03 is a multifunctional device which is Centralized controller MD-CCM03 provides a MD-CCM09 allows up to 64 indoor units making the
8:00 16:00 23:59

able to control up to 64 indoor units. And the superior way to manage the indoor units. Users are weekly schedule. Users can set up to 4 periods per
Sun 28°C 22°C 24°C

Mon 26°C 22°C 17°C 23°C


connection length can be up to 1,200m. With the able to make their own choice from locking the day and select the desired running mode and room Tue 26°C 22°C 17°C 23°C
newly designed machines, this device connects to wireless controller, locking the running mode or lock temperature. The operating object could be any Wed 26°C 22°C 17°C 23°C

the master outdoor unit, making the centralized the MD-CCM03’s keyboard, as they wish. indoor unit or all the indoor units. Thu 26°C 22°C 26°C

wiring quite simple.The 2 ways of connecting is as Fri 26°C 22°C 26°C

Sat 28°C off 24°C


follows:
Locking Locking Locking Centralized
Running Remote Keyboard Controller
X,Y,E X,Y,E X,Y,E X,Y,E Mode Controller Three lock modes Single/unified control mode
Centralized controller MD-CCM03 provides a The control object can be either single or all, making
superior way to manage the indoor units. Users are the controlling operation convenient and easy. With
Single/unified control mode able to make their own choice from locking the the operation signal feedback, users ensure their
Indoor unit working status display The control object can be either single or all, making wireless controller, locking the running mode or lock machines work at the precise working mode.
MD-CCM03 displays both the indoor units working the controlling operation convenient and easy. With the MD-CCM03’s keyboard, as they wish.
status and the error codes. Via checking the error the operation signal feedback, users ensure their
codes table in the user manual, users can easily machines work at the precise working mode. OPR.UNSUCCESS

find out the malfunction and call the repairman. Locking Locking Locking Centralized
Running Remote Keyboard Controller
Mode Controller
Error code or Connecting OPR.UNSUCCESS
protection code status matrix

GROUP QUERY RUN SET

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
(1.6)

#GROUPALL ERROR # MODE AUTO


00+
INLINE ON OFF PROTECT
16+

ROOM.TEMP SET.TEMP 32+


T3 OFF
FAN 48+
T2A
Hr ON T2B Hr
OPR.UNSUCCESS

Indoor unit working status display


MD-CCM03 displays both the indoor units working
Access to network monitoring status and the error codes. Via checking the error
Error code or
protection code
Connecting
status matrix

MD-CCM03 is able to bridge up to 64 indoor units to the network monitoring system and the building codes table in the user manual, users can easily find GROUP QUERY RUN SET

management system.
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16

(1.6)
#GROUPALL ERROR # MODE
out the malfunction and call the repairman.
AUTO
00+
INLINE ON OFF PROTECT
16+

ROOM.TEMP SET.TEMP 32+


T3 OFF
MAX.64 Hr ON
T2A
T2B Hr
FAN 48+

OPR.UNSUCCESS

MD-CCM03

Specifications Specifications
Model MD-CCM03 Model MD-NIM09

Dimensions(H×W×D)(mm) 170×110×70 Dimensions(H×W×D)(mm) 170×110×70

Power 198-242V(50/60Hz) Power 198-242V(50/60Hz)


63 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 64

Centralized Controller Central Control Software

WIRED CONTROLLER 3RD GENERATION


KJRF-180A MONITORING SYSTEM
Newly designed centralized controller controls up to 16
indoor units and 1 heat pump water heater in addition.

Functions Functions
Multiple machine control Single/unified control Friendly user interface
KJRF-180A is a multiple functions device, which can KJRF-180A provides an easy way to control the 3rd generation monitoring system offers a simple and explicit user interface to allow realize its functions
control both indoor air conditioners and heat pump indoor unit and water heater. User can quickly choose simply.3rd generations monitoring system is able to control up 1024 indoor units and 512 outdoor units.
water heater. Moreover, KJRF-180A is able to the water heater or the fresh air unit to adjust their
connect to the fresh air unit and realize the operation. running modes.
Group definition 3rd
KJRF-180A
Wall Mounted Unit

KJRF-180A Wall Mounted Unit


Fresh air
Wall Mounted Unit
Fresh air Water Heater Wall Mounted Unit

The layout drawing of the


Water Heater
floor makes it easy to select
the desired unit. Click the unit to operate

Graceful design Easy installation


KJRF-180A is designed with graceful appearance, KJRF-180A offers two different appearances to
especially suitable for the high class environment. mostly suit the installation. Both of them are easy to
The key lock function helps avoiding unnecessary operate.
operation by mistake.

Multiple functions
3rd generation system is able to realize the remote control of indoor units. The command of indoor unit
can be both the normal ones, such as changing the running modes, adjusting the temp., timer functions,
and the higher class command, such as excluding the other controllers to realize unique PC control.

Running 3rd generation


Specifications Normal Group Unique
monitoring
status
Funtions Settings PC Control
Model KJRF-180A Reports system

Dimensions(H×W×D)(mm) 180×122×69

Power 220V(50/60Hz)
65 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 66

Accessories Accessories

LONWORKS® BMS GATEWAY BACNET® BMS GATEWAY


MD-CCM07 MD-CCM08
Cooperate with the 3rd generation monitoring software. Contains 4 groups of RS-485 communication ports and be able to connect up to
Enables centralized control of up to 1024 indoor units and 512 outdoor units to 256 indoor units or 128 outdoor units to the BMS.
the LonWorks BMS. Be free to connect to the BMS or not.
Easily connects to the BMS system. Be compatible with 3rd generation monitoring software Firebird.
Ideal for scattered units of large projects, such as high office buildings, etc. Monitor machines via local network.

Network example Network example

Outdoor units
MD-CCM08
Indoor units

CCM02
UPS
CCM03
Indoor side RS485
Outdoor units

HUB
TCP/IP BACnet/IP protocol

CCM03 Indoor units

Monitoring BMS
system

Outdoor side Monitoring units via local web


MD-CCMO7 MD-CCM08 allows users explore the units via local network, simply using the Internet Explorer. Moreover,
gateway users can not only check the units running conditions, but also change the running parameter of the units, which
is quite convenient for users to control.

UPS is recommended only, not necessary.


Wide compatibility

Recommended config CCM08 has a wonderful adaptability to the BMS.


Operating system WIN2000/WIN XP SP4 Company BMS software Brand

CPU Pentium 4 2G or above


APOGEE
1 SIMENS APOGEE A N Y W H E R E

HDD 40G free space TM

Interface port 2 RS-232 terminals and 3 USB ports


Software 3rd generation monitoring software kit 2 TRANE Tracer Summit
TRACER SUMMT
Database Microsoft SQL Sever 2000 personal edition
Electricity meter Chint DTS634 or corresponding model
3 Honeywell Alerton

Packing list 4 Schneider Andover

Packing list MD-CCM07 and power converter

PC should be field supplied. 5 Johnson METASYS


3-core shield twisted pair lines should be applied to the network.
67 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 68

Accessories

HOTEL CARD KEY INTERFACE MODULE HRV


MD-NIM05
Cooperate with the wired controller to realized humanistic automatic control.
Heat recovery ventilator
High voltage power is unnecessary, making the device safe and steady.
Auto-restart function inside.
Iarger air supply rate Model Names
enhanced heat exchange efficiency
HRV-200 HRV-500
Installation example Electrical wiring enhanced energy saving property HRV-300 HRV-800
HRV-400 HRV-1000

The heat recovery ventilator (HRV) can reclaim


KJR-10B
heat energy lost through ventilation and reduces
KJR-10B
the room temperature fluctuation caused by
MD-NIM05
MD-NIM05
CN CN ventilation process. By utilizing the most
220V
KM
2 1
advanced technology and technics. Midea HRV
Card key
Card key
has extremely good performance. The heat HRV-1500 HRV-2000
AC contactor
Wired controller is necessary in this card-key system.
exchanged core is made of special paper
processed with chemical treatment, which could
Optional accessories
Specifications realize better temperature and humidity control of
Model MD-NIM05
the room environment. Temperature exchange
efficiency is above 65% and enthalpy exchange
Dimensions(H×W×D)(mm) 86×72.8×15.5

Power Powered from display panel. Extra power unnecessary.


efficiency between 50-65%.

INFRARED SENSOR CONTROLLER RA


(Returm air
SA
14。 from room)
MD-NIM09 Heat
Moisture
C

Automatically adjust the room environment. Cold air

Automatically extend the shutting down time, avoiding frequent ON/OFF.


0 0°C
SA
(Supply air
Moisture
Graceful appearance accommodates itself to the different buildings. EA
to room)
6。
C Heat Warm air

20°C
C

Installation example Electrical wiring Heat exchange plate

EA
Infra-red inductive controller

Infra-red
KJR-10B sensor (EXhust air
KJR-10B KJR-10B Display panel
Wire controller to outdoors)

MD-NIM09 MD-NIM09
MD-NIM09/E
CN3
CN2
CN1
OA
S1 (Fresh air from
Infra-red inductive
control box Low noise outdoors)
Indoor main board

MD-NIM09 works together with the wired controller. Sound proof material is used to guarantee quiet operation.

Compact design, flexible installation and easy maintenance


Optional accessories
Specifications
With a min. height of only 264mm and 23kg weight, the
Model MD-NIM09
unit provides best convenience and possibility for 264mm
Dimensions(H×W×D)(mm) Senor part: 46×30×25.6, Control box: 86×72.8×15.5 installation in limited spaces.
Power Powered from display panel. Extra power unnecessary.
69 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 70

Multi-modes for different situations Specifications


Model HRV-200 HRV-300 HRV-400 HRV-500
Heat exchange mode Power Supply V/ph/Hz 220-240V~1Ph~50Hz /220V~1Ph~60Hz

When air flow formed by the fans goes through the heat Heat exchange mode 65 65 65 65
Damper Temp. Exchange Efficiency (%) [50Hz] % 65 65 65 65
exchanged core in cross way, due to temperature difference 70 70 70 70
High 50 50 50 50
between two channels of the core, thermal transmission happens EA RA Enthalpy For Cooling Medium 50 50 50 50
naturally. Exchange Low 55 55 55 55
High % 55 55 60 60
In summer days, high temperature outdoor air gets cooled by Element Efficiency (%)
For Heating Medium 55 55 60 60
[50Hz]
indoor exhaust air; in winter, low temperature outdoor air gets OA SA Low 60 60 65 65
Heat High 27 30 32 35
heated by indoor exhaust air. So the energy contained in exhaust Exchange Medium 26 29 31 34
air can be reclaimed and energy efficiency gets improved. Sound Level
Mode Low
dB(A)
20 23 25 28
High 28 31 33 36
Bypass mode Bypass
Bypass mode Damper Mode
Medium
Low
27
22
30
25
32
27
35
30
Dimensions(W×D×H) mm 866×655×264 944×722×270 944×927×270 1,038×1,026×270
In mild climate areas or seasons, when temperature and humidity EA RA Machine Weight kg 23 26 31 41
level difference between indoor and outdoor is small, the unit Casing - Galvanized steel plate
Element Heat Exchange System - Air to air cross flow total heat (Sensible heat + latent heat) exchange
works as conventional ventilation fan. Both supply fan and Heat Exchange Element Material - Specially processed nonflammable paper
exhaust fan works at the same speed (Hi/mid/low/auto). OA SA Type - Centrifugal fan
Airflow Rate High 200 300 400 500
[50Hz] Medium m3/h 200 300 400 500

Air supply mode Fan


Low
High
150
75
225
75
300
80
375
80
ESP (Pa) [50Hz]
It is one kind of bypass mode with air supply fan speed higher than exhaust fan speed. It can Medium Pa 58 60 65 68
Low 35 40 43 45
be used in mild climate area where large amount fresh air is needed. Motor Output W 20 40 80 120
Duct diameter Φ/mm 144 144 144 194

Exhaust air mode Auto mode Operation ambient condition - '-7°C-43°C (DB), 80%RH or less

It is also one kind of bypass mode with exhaust fan speed The controller chooses heat exchange mode or Specifications
higher than air supply fan speed. It can be used in mild bypass mode according to the temperature
climate area where large amount exhaust air needs to be difference between outdoor and indoor Model HRV-800 HRV-1000 HRV-1500 HRV-2000

expelled. temperature. Both the two fans work at low speed. Power Supply V/ph/Hz 220-240V~1Ph~50Hz /220V~1Ph~60Hz 380V~3Ph~50Hz /220V~3Ph~60Hz
65 65 65 65
Temp. Exchange Efficiency (%) [50Hz] % 65 65 / /
Flexible control High
70
50
70
50
/
50
/
50
Enthalpy For Cooling Medium 50 50 / /
Interlocking control with other indoor units by controller is possible Exchange Low 55 55 / /
High % 60 60 60 60
Efficiency (%)
For Heating Medium 60 60 / /
EA [50Hz]
OA Low 65 65 / /
Heat High 39 40 51 53
Duct (Obtain locally) Medium 38 39
Exchange / /
Mode Low 32 33 / /
IDU Sound Level dB(A)
High 40 41 52 54
Bypass
Medium 39 40 / /
RA Mode
SA Low 34 35 / /
Dimensions(W×D×H) mm 1,286×1,006×388 1,286×1,256×388 1,600×1,270×540 1,650×1,470×540
IDU Machine Weight kg 62 79 163 182
Casing - Galvanized steel plate
Centralized control Heat Exchange System - Air to air cross flow total heat (Sensible heat + latent heat) exchange
SA Heat Exchange Element Material - Specially processed nonflammable paper
Type - Centrifugal fan
CCM03
Airflow Rate High 800 1,000 1,500 2,000
[50Hz] Medium m3/h 800 1,000 / /
Low 600 750 / /
Fan High 100 100 160 170
ESP (Pa) [50Hz] Medium Pa 82 85 / /
Low 54 58 / /
Motor Output W 360 360 450 450
Duct diameter Φ/mm 242 242 346×326 346×326
Operation ambient condition - '-7°C-43°C (DB), 80%RH or less

Note:
1. For the units model of HRV (200-1000), there are 3-speed adjustable air volume (Hi, Med, Low), but for the units model of HRV (1500-2000), there are only 1-speed which cannot be adjusted.
2. Sound level is measured at 1.4m below the center of the body in an anechoic chamber..
3. Airflow rate can transmit between low mode and high mode
4. Temperature Exchange Efficiency is the mean value between cooling and heating
5. Efficiency is measured under the following conditions:
* Cooling Condition: Air Exhaust Temp. 27°C DB,19.5°CWB., Fresh Air Temp. 35°C DB,28°CWB
* Heating Condition: Air Exhaust Temp. 21°C DB,13°CWB., Fresh Air Temp. 5°C DB,2°CWB
71 Full DC Inverter Mini VRF Full DC Inverter Mini VRF 72

Accessories Memo

Model Feature Model name Description

FQZHN-01C A<16.6kw

Branch joint for

indoor unit

FQZHN-02C 16.6kW≤A<23kW

SBH-01
For low/high static pressure duct type indoor unit
Drain pump SBH-03
(Option)
SBH-04

A*:The total capacity of indoor units following this branch joint.

Refrigerant Distributors
Indoor branch drawing
Name Gas side joints Liquid Side Joints
(ID:15.9)

OD:19.1

ID:19.1
ID:12.7

OD:19.1

ID:19.1

ID:15.9

OD:9.5

ID:9.5
ID:6.4

OD:12.7

ID:9.5

FQZHN-01C
OD:19.1
ID:12.7

(ID:15.9)

OD:9.5
ID:9.5
ID:6.4
(ID:19.1)

OD:22.2

ID:22.2
ID:15.9

OD:22.2

OD:12.7

ID:12.7
ID:22.2

ID:25.4

ID:9.5
ID:6.4

OD:12.7

ID:12.7
ID:9.5

FQZHN-02C
OD:22.2
ID:15.9
ID:12.7

(ID:19.1)

OD:12.7
ID:6.4

ID:9.5