You are on page 1of 3

Timers for UE

Timer Start Stop At expiry


T300 Transmission of Reception of RRC Retransmit RRC
RRC CONNECTION CONNECTION SETUP CONNECTION REQUEST
REQUEST if V300 =< N300, else
go to Idle mode
T302 Transmission of Reception of CELL Retransmit CELL
CELL UPDATE/URA UPDATE CONFIRM/URA UPDATE/URA UPDATE if
UPDATE UPDATE CONFIRM V302 =< N302, else, go
to Idle mode
T304 Transmission of UE Reception of UE Retransmit UE
CAPABILITY CAPABILITY CAPABILITY
INFORMATION INFORMATION INFORMATION if V304
CONFIRM =< N304, else initiate a
cell update procedure
T305 Entering Entering another state. Transmit CELL UPDATE
CELL_FACH or if T307 is not activated
URA_PCH or and the UE detects “in
CELL_PCH state. service area”.
Reception of CELL Otherwise, if T307 is not
UDPATE active, start T307.
CONFIRM/URA
UPDATE CONFIRM.
T307 When the timer When the UE detects “in Transit to idle mode
T305 has expired service area”.
and the UE detects
“out of service
area”.
T308 Transmission of Not stopped Transmit RRC
RRC CONNECTION CONNECTION RELEASE
RELEASE COMPLETE if V308
COMPLETE <=N308, else go to idle
mode.
T309 Upon reception of Successful response to Resume the connection
CELL CHANGE a connection to UTRAN
ORDER FROM establishment request
UTRAN message in the new cell.
T310 Transmission of Reception of PHYSICAL Transmit PUSCH
PUSCH CAPACITY SHARED CHANNEL CAPACITY REQUEST if
REQUEST ALLOCATION V310 =< N310, else
procedure stops.
T311 Reception of Reception of PHYSICAL UE may initiate a
PHYSICAL SHARED SHARED CHANNEL PUSCH capacity request
CHANNEL ALLOCATION message procedure.
ALLOCATION with CHOICE “PUSCH
message with the allocation” set to
CHOICE “PUSCH “PUSCH allocation
allocation” set to assignment”.
“PUSCH allocation
pending”.
T312 When the UE starts When the UE detects The criteria for physical
to establish N312 “in sync” channel establishment
dedicated CH indication from L1. failure is fulfilled
T313 When the UE When the UE detects The criteria for Radio
detects consecutive N315 “in Link failure is fulfilled
consecutive N313 sync” indication from
L1.
Timer Start Stop At expiry
“out of sync”
indication from L1.
T314 When the criteria When the Cell Update See subclause 8.3.1.13
for radio link procedure has been
failure are fulfilled. completed.
The timer is
started if radio
bearer(s) that are
associated with
T314 exist of if
only RRC
connection exists.
T315 When the criteria When the Cell Update See subclause 8.3.1.14
for radio link procedure has been
failure are fulfilled. completed.
The timer is
started only if
radio bearer(s)
that are associated
with T315 exist.
T316 When the UE When the UE detects “in Initiate cell update
detects “out of service area”. procedure if in service
service area” in area is detected.
URA_PCH or Otherwise start timer
CELL_PCH state T317, transit to
CELL_FACH state and
initiate cell update
procedure when the UE
detects “in service
area”.
T317 When the T316 When the UE detects “in Transit to idle mode
expires or when in service area”.
CELL_FACH state,
the UE detects “out
of service area”.

Counters for UE
Counter Reset Incremented When reaching max
value
V300 When initiating the Upon expiry of T300. When V300 > N300, the
procedure RRC UE enters idle mode.
connection
establishment
V302 When initiating the Upon expiry of T302 When V302 > N302 the
procedure Cell UE enters idle mode.
update or URA
update
V304 When sending the Upon expiry of T304 When V304 > N304 the
first UE UE initiates the Cell
CAPABILITY update procedure
INFORMATION
message.
V308 When sending the Upon expiry of T308 When V308 > N308 the
first RRC UE stops re-transmitting
CONNECTION the RRC CONNECTION
Counter Reset Incremented When reaching max
value
RELEASE RELEASE COMPLETE
COMPLETE message.
message in a RRC
connection release
procedure.
V310 When sending the Upon expiry of T310 When V310 > N310 the
first PUSCH UE stops re-transmitting
CAPACITY the PUSCH CAPACITY
REQUEST message REQUEST message.
in a PUSCH
capacity request
procedure

UE constants and parameters


Constant Usage
N300 Maximum number of retransmissions of the RRC CONNECTION
REQUEST message
N302 Maximum number of retransmissions of the CELL UPDATE /
URA UPDATE message
N304 Maximum number of retransmissions of the UE CAPABILITY
INFORMATION message
N308 Maximum number of retransmissions of the RRC CONNECTION
RELEASE COMPLETE message
N310 Maximum number of retransmission of the PUSCH CAPACITY
REQUEST message
N312 Maximum number of “in sync” received from L1.
N313 Maximum number of successive “out of sync” received from L1.
N315 Maximum number of successive “in sync” received from L1
during T313 is activated.