SUBMITTAL DATA: PKA-A36KA7 & PUY-A36NKA7(-BS)

P-SERIES 36,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEM

Job Name:
System Reference: Date:

Indoor Unit: Outdoor Unit:


PKA-A36KA7 □ PUY-A36NKA7
□ PUY-A36NKA7-BS

INDOOR UNIT FEATURES


• Sleek, compact design
• Simple installation
• Vane setting for air flow direction control
• Auto fan speed mode
• Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offices, and more

OUTDOOR UNIT FEATURES


• Variable speed INVERTER-driven compressor
• Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30)
• Low ambient cooling down to -20ºF providing 100% capacity (only for PUY models with wind baffles installed)
• 24-hour continuous operation (cooling mode)
• High pressure protection
• Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers
• Superior energy and operational efficiency

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.
SPECIFICATIONS: PKA-A36KA7 & PUY-A36NKA7(-BS)

Indoor Unit PKA-A36KA7


Model Number PUY-A36NKA7
Outdoor Unit
PUY-A36NKA7-BS
Maximum Capacity Btu/h 36,000
Rated Capacity Btu/h 36,000
Minimum Capacity Btu/h 16,000
Maximum Power Input W 3,330
Cooling*1
Rated Power Input W 3,330
Moisture Removal Pints/h 9.7
Sensible Heat Factor 0.70
Power Factor % 96.5
SEER 18.8
Efficiency
EER *1 10.8
Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz
Guaranteed Voltage Range V AC 198 – 253
Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230
Electrical Voltage: Indoor - Outdoor, S2-S3 V DC 24
Voltage: Indoor - Remote controller V DC 12
Recommended Fuse/Breaker Size A 30
Recommended Wire Size (Indoor - Outdoor) AWG 14
MCA A 1
Fan Motor Full Load Amperage A 0.57
Fan Motor Output W 56
Airflow Rate, Dry CFM 705-810-920
Airflow Rate, Wet CFM 635-730-830
External Static Pressure in.WG n/a

Indoor Unit Sound Pressure Level dB(A) 43-46-49


Drain Pipe Size In. (mm) 5/8 (16)
Condensate Lift Mechanism, Max. Distance In. (mm) n/a
Heat Exchanger Type Plate fin coil
External Finish Color White Munsell 1.0Y 9.2/0.2
W: In. (mm) 46-1/16 (1170)
Unit Dimensions
D: In. (mm) 11-5/8 (295)

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.
SPECIFICATIONS: PKA-A36KA7 & PUY-A36NKA7(-BS)

Indoor Unit PKA-A36KA7


Model Number PUY-A36NKA7
Outdoor Unit
PUY-A36NKA7-BS
H: In. (mm) 14-3/8 (365)
W: In. 51
Package Dimensions D: In. 18-8/16
H: In. 14-4/16
Unit Weight Lbs. (kg) 46 (21)
Package Weight Lbs. 53
Indoor Unit Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB
Operating
Temperature range
MCA A 25
MOCP A 31
Fan Motor Full Load Amperage A 0.5 + 0.5
Fan Motor Output W 74 + 74
Airflow Rate CFM 3,880
Refrigerant Control Electronic Expansion Valve
Heat Exchanger Type Cross fin
Sound Pressure Level, Cooling*1 dB(A) 52
Sound Pressure Level, Heating*2 dB(A) 53
Compressor Type INVERTER-driven twin rotary
Compressor Model MNB33FBRMC-L
Outdoor Unit
Compressor Rated Load Amps A 8
Compressor Locked Rotor Amps A 13
Compressor Oil Type // Charge oz. FV50S // 45
External Finish Color Ivory Munsell 3Y 7.8/1.1
Base Pan Heater n/a
W: In. (mm) 1050 [41-5/16]
Unit Dimensions D: In. (mm) 13 + 1-3/16 (330 + 30)
H: In. (mm) 52-11/16 (1338)
W: In. 42-15/16
Package Dimensions D: In. 17-11/16
H: In. 56-4/16

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.
SPECIFICATIONS: PKA-A36KA7 & PUY-A36NKA7(-BS)

Indoor Unit PKA-A36KA7


Model Number PUY-A36NKA7
Outdoor Unit
PUY-A36NKA7-BS
Unit Weight Lbs. (kg) 211 (96)
Package Weight Lbs. (kg) 243 (110)
Outdoor Unit Cooling Intake Air Temp (Maximum / Minimum) °F 115 DB / -20* DB
Operating
Temperature
Range
Type R410A
Refrigerant
Charge Lbs, oz 10 lbs, 6 oz
Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88)
Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52)
Piping Maximum Piping Length Ft. (m) 225 (69)
Maximum Height Difference Ft. (m) 100 (30)
Maximum Number of Bends 15

AHRI Rated Conditions (Rated *1 Cooling (Indoor // Outdoor) °F 80°F DB, 67°F WB // 95°F DB, 75°F WB
data is determined at a fixed
compressor speed)
Notes
*Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -20°F - 115°F. Refer to wind
baffle documentation for further information.
**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures
SEACOAST PROTECTION
• External Outer Panel: Phosphate coating + Acrylic-Enamel coating
• Fan Motor Support: Epoxy resin coating (at edge face)
• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)
• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne
contaminants.

Notes:

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.
ACCESSORIES: PKA-A36KA7

3-Pole Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] □ TAZ-MS303
Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) □ DPLS2
MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/ Reservoir & Sensor (110V) □ X87-711 - 110
up to 48,000 Btu/h [recommended]
MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/ Reservoir & Sensor □ X87-721 - 208/230
(208/230V) up to 48,000 Btu/h [recommended]
Extension Cord for Blue Diamond Pump □ C13-103
Sauermann Mini-Condensation pump (115V) □ SI30-115
Sauermann Mini-Condensation pump (230V) □ SI30-230
MegaBlue Blue Diamond Condensate Pump (110-230V) □ X87-835
Remote Sensor (extensible) □ PAC-SE41TS-E
Connector for CN32 (remote ON/OFF) □ PAC-SE55RA-E
External fan / Heater control relay adapter □ CN24RELAY-KIT-CM3
Backlit, wall-mounted, wireless □ MHK1
Wireless Remote Controller □ MRCH1
Wireless Receiver □ MFH1
Portable Central Controller □ MCCH1
Outside Air Sensor □ MOS1
Wireless adapter □ PAC-USWHS002-WF-1
BACnet® and Modbus Interface □ PAC-UKPRC001-CN-1
Wall-mounted, Wired □ PAC-YT53CRAU-J
Wired Remote Controller □ PAR-33MAA-J
T-STAT Interface □ PAC-US444CN-1
Simple remote controller □ PAC-YT53CRAU
Wireless Remote Controller □ PAR-FL32MA-E
Wire for Remote ON/OFF with CN32 connector □ PAC-715AD
Lockdown Bracket for wireless, hand-held, remote controllers □ RCMKP1CB

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.
ACCESSORIES: PUY-A36NKA7(-BS)

Twinning Distribution Pipe (50:50) □ MSDD-50TR-E


Air Outlet Guide □ PAC-SH96SG-E (two
pieces are required)
Front Wind Baffle □ WB-PA3 (two pieces are
required)
Hail Guard □ HG-A2
Side Advanced Wind Baffle □ WB-SD6
Rear Advanced Wind Baffle □ WB-RE6
Drain Socket □ PAC-SG61DS-E
Centralized Drain Pan □ PAC-SH97DP-E
Control/Service Tool □ PAC-SK52ST
Wall Mounting Bracket (Powder-coated Steel) □ QCWB2000M-1
Wall Mounting Bracket (316 Series Stainless Steel) □ QSWBSS
M-NET Control Adapter for Building Management System □ PAC-SF83MA-E
Outdoor Unit Mounting Pad 24" x 42" x 3" □ ULTRILITE2
Outdoor Unit 3-1/4 inch Mounting Base - Pair (Plastic) □ DSD-400N
MiniSplit Mounting Stand-Dual Fan Models - 12" □ QSMS1202M
MiniSplit Mounting Stand-Dual Fan Models - 18" □ QSMS1802M
MiniSplit Mounting Stand-Dual Fan Models - 24" □ QSMS2402M
3/8 x 5/8 x 10' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-10
3/8 x 5/8 x 15' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-15
3/8 x 5/8 x 30' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-30
3/8 x 5/8 x 50' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-50
3/8 x 5/8 x 65' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-65
3/8 x 5/8 x 100' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-100

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.
DIMENSIONS: PKA-A36KA7 & PUY-A36NKA7 (-BS)

6 OUTLINES AND DIMENSIONS


PKA-A36KA7

2-9/16(65.2)
Top side
Unit: inch (mm)
16-11/16(423.7) 17(431.7)
5-17/32(140.3)

7/16(11)

Left side Right side


Front side

Mount board
14-3/8(365)

Knockout hole
for left piping

2-29/32(74) 33-21/32(855) 9-1/2(241) 11-5/8(295) 3/16(5)


A 46-1/16(1170)
Front side(Grille open) Operation lamp
Knockout hole
for right piping
DEFROST/STAND BY lamp
Receiver

Terminal block for Outdoor unit


2-3/32(53)

23/32(18)
1-1/4(32)

Terminal block for power supply (option)


Terminal block for
MA-remote controller

Filter hook Emergency operation switch


(cooling/heating)
1-3/16(30)
1-3/8(35) Drain hose 3 17-15/32(444)Gas pipe 2 4-27/32(123)
2-19/32(66) 1 6-1/16(154)
18-31/32(482)Liquid pipe
5-9/32(134)
Under side

Piping connection
Vane(auto) Louver(manual) Refrigerant pipe: 3/8 O.D([9.52)
B B
1 Liquid pipe
Knockout hole
Flared connection: 3/8F
Sleeve
for lower piping Refrigerant pipe: 5/8 O.D([15.88)
(purchased locally) Through hole 2 Gas pipe Flared connection: 5/8F
[2-15/16 [2-15/16~[3-5/32
([75) ([75~[80) 3 Drain hose 5/8([16) O.D
Effective length: 23-1/32 (585)
Required space(Indoor unit)

Knockout hole for piping


Air inlet
3-1/32(77)

3-1/32(77)
2-5/8(67)
Min.1-7/8(48)

2-5/8(67)
2-9/16(65)

B A
C
5/16(7.8)
5/16(7.8)
Min.9/32(7)

Air outlet
Min.9-27/32(250)

Min.8-21/32(220) Min.3-31/32(100.5) 3-1/32(77) 2-9/16(65)


2-9/16(65)
3-7/16(87)
Min.2-1/16(52.3)
13/32(10.7)

Center measurement hole


[3/32([2.5)
2-1/8(54)

1/8(3)
0

4-[11/32([9) Bolt hole


16-3/32(408.5)

18-5/16(465.5)
16-3/32(408.5)

Mount board
14-11/32(364)

14-11/32(364)
20-3/8(517.4)

15-1/8(384.5)
17-9/32(439)

17-9/32(439)
4-11/32(110)

4-11/32(110)
17-7/8(454)

15-1/8(384)

12-3/8(314)

12-3/8(314)

17-7/8(454)
13/32(10)

13/32(10)
2-3/8(60)

2-3/8(60)

75-[3/16([5.1)
Tapping Indoor unit outline
screw hole
0

2-1/8(54)
1-1/4(32)
31/32(25)
5/8(15.5) 1/2(12.5)
0 0
31/32(25) 1/2(12.5)
1-31/32(50) 1-15/32(37.5)
2-15/16(75) 2-15/32(62.5)
3-15/16(100) 3-7/16(87.5)
4-19/32(117) 4-1/8(104.5)
4-29/32(125) 5-3/32(129.5)
5-19/32(142) 6-9/16(167)
7-9/16(192) 8-17/32(217)
9-17/32(242) 9-1/32(229.5)
10-13/32(264)
11(279.5)
11-1/2(292)
11-1/2(292)
12-5/32(308.5)
12-1/4(311)
R1-15
0
20-7/8(530.5)

13-11/32(339)

7-7/16(189)
23-1/32(585)

15-1/8(384)
8-17/32(216.5)

13-11/32(339)
13-3/4(349.2)
16-15/16(430.5)

23-1/32(585)
15-1/8(384)

17-11/16(449.2)
/32(R
37.5)

Knockout hole for


rear piping Wall hole for
right rear piping

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.
DIMENSIONS: PKA-A36KA7 & PUY-A36NKA7 (-BS)

PUY-A36NKA7(-BS)

PUZ-A36NKA7-BS
PUZ-A36NKA7
Unit: mm<in>
OCH636

1 FREE SPACE (Around the unit) 2 SERVICE SPACE 3 FOUNDATION BOLTS 4 PIPING-WIRING DIRECTIONS Rear Air Intake
2-U Shaped notched holes
The diagram below shows a basic example. Dimensions of space needed Please secure the unit firmly Piping and wiring connections (Foundation Bolt M10<W3/8>)
Explantion of particular details are for service access are with 4 foundation (M10<W3/8>) bolts. can be made from 4 directions: 225 <8-27/32> 600 <23-5/8> 225 <8-27/32>
given in the installation manuals etc. (Bolts and washers must be

19 <3/4>
shown in the below diagram. FRONT, Right, Rear and Below. Installation Feet
purchased locally.)

<5-29/32>
FREE

Min.
150
<Foundation bolt height>
Side Air Intake

417 <16-13/32>
370 <14-9/16>
330 <13>
Min. 15mm Min. 15mm Min. 1000mm Min. 150mm
<19-11/16>
<3/5> <3/5> <39-3/8> <5-29/32> 56 <2-7/32>
Min.
500
Min.

40<1-9/16>
15 <3/5> 0
FOUNDATION

30 <1-3/16>
70 <2-3/4>
Service space Min. Min.
53 <2-3/32>

25 <31/32>

PUZ-A42NKA7-BS
PUZ-A42NKA7
500 50 Max.

28 <1-3/32>
<19-11/16> <2> Air Discharge 2-12×36 Oval holes 60 <2-3/8> 42 <1-21/32>
(Foundation Bolt M10<W3/8>)

1050 <41-11/32>

( )
Side Air Intake 362 <14-1/4> Terminal connection
Earth terminal Left ... Power supply wiring
Rear Air Intake Right ... Indoor/Outdoor wiring

Example of Notes
1 ... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F) Service panel
...
2 Refrigerant LIQUID pipe connection (FLARE) ø9.52(3/8F)
*1 ... Indication of STOP VALVE connection location.

1338 <52-11/16>
632 <24-7/8>
Handle for Handle for moving
moving

1063 <41-7/8>
16

PUY-A36NKA7-BS
PUY-A36NKA7
Handle for
moving Handle for Air intake
moving

*1 450 <17-23/32>
2

*1 442 <17-2/5>
1

369 <14-17/32>
26 <1-1/32>
Piping Knockout Hole Details Front piping cover
Rear piping cover

86 <3-3/8>
When installing the conduit. 81 <3-3/16>
60 <2-3/8> 55 <2-3/16> 53 <2-3/32> 60 <2-3/8> 55 <2-3/16> 60 <2-3/8> Set the attachment to the
Conduit hole Conduit hole Rear trunking hole Conduit hole inner side of each panel.
(ø 37<1-15/32>knockout) Conduit hole (ø 24<15/16>knockout) (Knockout) (ø 24<15/16>knockout)
60 <2-3/8> 22.5 <7/8>
(ø 24<15/16>knockout)
<5-11/32> <6-1/16>

Front trunking hole Conduit hole 3/4 Conduit


154

(Knockout) Conduit hole ø 27.8<1-3/32>


(ø 37<1-15/32>knockout) (ø 37<1-15/32>knockout) attachment
55 <2-3/16>

Right piping hole


60 <2-3/8>
61 <2-3/8>

ø 22.2<7/8>
5<3/16>

(Knockout)
5<3/16>

Bottom piping hole


55 <2-3/16>
73 <2-7/8>

(Knockout)
73 <2-7/8>

136
27 <1-1/16>

ø 92 ø 92
<3-5/8> 1/2 Conduit
<3-5/8>
<3-5/8>

24.7 <31/32>

attachment
5<3/16>
92

100
<3ø-592 <3-15/16> 45 <1-25/32>
/8>

PUY-A42NKA7-BS
PUY-A42NKA7
Rear piping hole 160 160 160 Drain hole
(Knockout) 110 <14-11/32> <6-5/16> <6-5/16> <6-5/16> (5-ø33<1-5/16>)
26 <1-1/32>

55 <2-3/16>
26 <1-1/32>

Right trunking hole 92 <3-5/8>


27 <1-1/16>

27 <1-1/16>
26 <1-1/32>
73 <2-7/8>

Scale 1:5
Front piping hole 75 <2-15/16> 29 <1-5/32> (Knockout) 75 <2-15/16>
(Knockout) 92 <3-5/8> 92 <3-5/8>

1340 Satellite Boulevard, Suwanee, GA 30024


Toll Free: 800-433-4822 www.mehvac.com

FORM# PKA-A36KA7 / PUY-A30NKA7(-BS) - 201710

Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.

You might also like