Certificate of Compliance for SVDR SHI-CQ-3-007

Rev.0
(Samsung Voyage Data Recorder) Page: 1/5

Item B.H.Kim S.H.Kwon T.W.Kim


1
Added 6.Feb.2015 6.Feb.2015 6.Feb.2015
First issue T.H.Kim J.M.Jeong T.C.Lee
0
for SVDR-3000 07.Aug.2008 07.Aug.2008 07.Aug.2008

1
Certificate of Compliance for SVDR SHI-CQ-3-007
Rev.0
(Samsung Voyage Data Recorder) Page: 2/5

Rev.No Description Prepared by Reviewed by Approved by


Hull No. H2040 Shipyard SHI
IMO Vessel
Vessel Name SERTANEJO SPIRIT 9637715
Identification No.
Flag BAHAMAS Classification ABS
VDR Manufacture &
SAMSUNG – SVDR3000 VDR Serial No. VR308L10M310
Model
RUA GAVIAO 70, NOVO
Name of ORION SAFETY Address of
HORIZONTE, SERRA/ES,
Service supplier STATION Service supplier
BRAZIL

YURI NEVES Inspection Place RIO DE JANEIRO, RJ


Inspector
MARTINUZO & Date NOV 11TH, 2015

A. Visual Inspection

Unit No. Check & Test Item Result


Program 1 No alarm message was activated XOK □NOK
1 The capsule is installed avoiding obstructions XOK □NOK
2 Color has enough visibility XOK □NOK
Capsule 3 Sealing is reliable XOK □NOK
4 Cable Connection has no damage XOK □NOK
1 Cable and Termination have no damage XOK □NOK
Remote Operating and Monitoring Unit has enough
2 XOK □NOK
ROMU brightness and correct operation
3 The display of ROMU is not interfered XOK □NOK
4 No alarms activated XOK □NOK
1 The SRPS has no alarm activated and not bypassed XOK □NOK
SRPS
2 Cable(s) have no damage XOK □NOK
SVIU 1 Cable and Termination have no damage XOK □NOK
SAIU 1 Cable and Termination have no damage XOK □NOK
SSIU 1 Cable and Termination have no damage XOK □NOK
Interface
1 No damaged Interface Module XOK □NOK
Module
MIC 1 No damaged microphone XOK □NOK

B. Battery Test
Step Check & Test Item Result

2
Certificate of Compliance for SVDR SHI-CQ-3-007
Rev.0
(Samsung Voyage Data Recorder) Page: 3/5

Place the Tester Probes in contact with the


beacon water switch pins with correct
polarities(+,-)
(From the front of beacon reading the characters
XOK □NOK
on the beacon correctly,
“+” is righthand side and “-“ is lefthand side)
Battery
Read voltage : ( 2.99V)
Check
And confirm it is 2.97V or greater
Capsul Confirm the service date is left 12 months by
e checking
□ [SERVICE BEACON/BATTERY BY END OF] XOK □NOK
X [SERVICE BEACON/MANUFACTURE DATE]
(INSTALLED AT : NOVEMBER 2015)
Place the Tester Probes on the beacon correctly
Beacon and
Operation press the Red Button on the tester. Confirm XOK □NOK
al Test beacon is activated and a pinging sound is
audible.
Confirm that the expiration date of UPS is not
expired. (Lifetime of UPS battery is 4 years after
UPS Check first startup date marked on battery label) XOK □NOK
[EXPIRATION DATE]
( OCT-2016 )

C. Shutdown and Startup Operation Test


Step Shutdown Procedure Result
Shutdown and Startup each unit of SVDR
1 XOK □NOK
- System automatically Starts after boot up and no fault

D. System Operation Test


Unit No. Check & Test Item Result
Video signal on SVDR Main Display is correct(if
1 XOK □NOK
fitted)
All Serial Interfaces are running without any fault or
2 XOK □NOK
alarm
Generate sample alarm by disconnecting the terminal
ROMU #1(or#2) of SSIU terminal block. And confirm
3 XOK □NOK
alarming on ROMU with display message
“No Signal from GPS(or DGPS)”
Press “ALARM ACK” button to stop buzz alarming.
4 Put back the disconnected wire to clear Alarm XOK □NOK
Message

3
Certificate of Compliance for SVDR SHI-CQ-3-007
Rev.0
(Samsung Voyage Data Recorder) Page: 4/5

Check the response on the command


“PING 192.168.3.200-t”
1 XOK □NOK
Capsule “Reply from 192.168.3.200: byte=32 time<10ms
TTL=128”

Cut off the main power and check automatic


1 switching to power backup mode(confirm alarming on XOK □NOK
SRPS and ROMU)
Confirm that VDR continues to operate for at least
SRPS
1 h 55 min and automatically stops recording no
2 XOK □NOK
later than 2 h 5 min after the external power is
removed

E. Records and Comments from the Checks


Item Records or Comments Result
Check the 12 hours recorded data from Protective Capsule
(Using the Playback Software)
Recording 1. Audio XOK □NOK
Data 2. VHF XOK □NOK
3. Radar XOK □NOK
4. NAV data XOK □NOK

Any Changes or Repair of Sensors : □YES XNO


Sensors

Any Signal Added/Deleted or Modified : □YES XNO


Serial
Interface

Completio Confirm that the system is brought back to normal


XOK □NOK
n of Tests operating condition after the tests are completed.

4
Certificate of Compliance for SVDR SHI-CQ-3-007
Rev.0
(Samsung Voyage Data Recorder) Page: 5/5

Comments from Inspection:

Acoustic beacon was replaced (3 years) SN:14508-00- 29224 MAKER: NOVEGA


installed at November 11th, 2015
All tests had been perfomed well, VDR with no faults

CERTIFICATE NUMBER: SHI/DD-747

Inspection Result
Confirmed that the VDR installed on the vessel is SATISFACTORY with no
XYES □NO
fault

Signed by Manufacturer’s Certified Signed by Vessel’s Representative


Representative

YURI NEVES MARTINUZZO [ ]


Date : NOVEMBER 11th, 2015 Date : NOVEMBER 11th, 2015