You are on page 1of 13

Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)

COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-1

COLUMN/WALL PUNCHING SHEAR REPORT


Column: 2C1 (Storey: 2)
================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C1 2 43.0 17.2 2.4 43.0 17.2 2.4

Column Classification: Corner

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 90000.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 43.0 kN x= 675.0 mm V-eff= 53.8 kN
2-Direction Punching Check:Vt= 43.0 kN x= 375.0 mm V-eff= 53.8 kN
Stress Check: (V-eff= 53.8 kN) v= 0.00 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 1050.0 mm Area (A)= 253125.01 mm2
1-Direction Punching Check:Vt= 38.2 kN x= 675.0 mm V-eff= 47.8 kN
Ast= 314.16 mm2 v= 0.18 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 38.2 kN x= 375.0 mm V-eff= 47.8 kN
Ast= 314.16 mm2 v= 0.18 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C2 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C2 2 91.2 -2.7 6.1 91.2 2.7 6.1

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 900.0 mm Area (A0)= 90000.00 mm2
1-Direction Punching Check:Vt= 91.2 kN x= 675.0 mm V-eff= 97.2 kN
2-Direction Punching Check:Vt= 91.2 kN x= 525.0 mm V-eff= 108.7 kN
Stress Check: (V-eff= 108.7 kN) v= 0.48 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2400.0 mm Area (A)= 708750.01 mm2
1-Direction Punching Check:Vt= 77.8 kN x= 675.0 mm V-eff= 83.8 kN
Ast= 314.16 mm2 v= 0.14 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 77.8 kN x= 525.0 mm V-eff= 95.3 kN
Ast= 314.16 mm2 v= 0.16 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C3 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C3 2 88.7 1.1 6.1 88.7 1.1 6.1

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 900.0 mm Area (A0)= 90000.00 mm2
1-Direction Punching Check:Vt= 88.7 kN x= 675.0 mm V-eff= 91.0 kN
2-Direction Punching Check:Vt= 88.7 kN x= 525.0 mm V-eff= 106.1 kN
Stress Check: (V-eff= 106.1 kN) v= 0.47 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2400.0 mm Area (A)= 708750.02 mm2
1-Direction Punching Check:Vt= 75.2 kN x= 675.0 mm V-eff= 77.6 kN
Ast= 314.16 mm2 v= 0.13 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 75.2 kN x= 525.0 mm V-eff= 92.7 kN
Ast= 314.16 mm2 v= 0.15 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C4 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-2

------- --- ---------- ---------- ---------- ---------- ---------- ----------


2C4 2 67.6 -6.1 5.4 67.6 6.1 5.4

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 900.0 mm Area (A0)= 90000.00 mm2
1-Direction Punching Check:Vt= 67.6 kN x= 675.0 mm V-eff= 81.2 kN
2-Direction Punching Check:Vt= 67.6 kN x= 525.0 mm V-eff= 83.0 kN
Stress Check: (V-eff= 83.0 kN) v= 0.37 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2400.0 mm Area (A)= 708750.04 mm2
1-Direction Punching Check:Vt= 54.2 kN x= 675.0 mm V-eff= 67.8 kN
Ast= 314.16 mm2 v= 0.11 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 54.2 kN x= 525.0 mm V-eff= 69.6 kN
Ast= 314.16 mm2 v= 0.12 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C5 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C5 2 31.0 -0.9 12.1 31.0 0.9 12.1

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 600.0 mm Area (A0)= 90000.00 mm2
1-Direction Punching Check:Vt= 31.0 kN x= 337.5 mm V-eff= 34.9 kN
2-Direction Punching Check:Vt= 31.0 kN x= 337.5 mm V-eff= 85.0 kN
Stress Check: (V-eff= 85.0 kN) v= 0.57 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 1350.0 mm Area (A)= 455625.00 mm2
1-Direction Punching Check:Vt= 22.4 kN x= 337.5 mm V-eff= 26.3 kN
Ast= 314.16 mm2 v= 0.08 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 22.4 kN x= 337.5 mm V-eff= 76.4 kN
Ast= 314.16 mm2 v= 0.23 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C9 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C9 2 274.7 125.3 47.9 274.7 125.3 47.9

Column Classification: Corner

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 200.0 d-eff= 135.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 1200.0 mm Area (A0)= 180000.00 mm2
1-Direction Punching Check:Vt= 274.7 kN x= 1005.0 mm V-eff= 343.4 kN
2-Direction Punching Check:Vt= 274.7 kN x= 1005.0 mm V-eff= 343.4 kN
Stress Check: (V-eff= 343.4 kN) v= 2.12 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 135.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2010.0 mm Area (A)= 505012.49 mm2
1-Direction Punching Check:Vt= 266.9 kN x= 1005.0 mm V-eff= 333.6 kN
Ast= 6544.99 mm2 v= 1.23 < vc=1.34 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 266.9 kN x= 1005.0 mm V-eff= 333.6 kN
Ast= 6544.99 mm2 v= 1.23 < vc=1.34 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C10 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C10 2 497.0 -12.1 59.9 497.0 12.1 59.9

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 200.0 d-eff= 135.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2000.0 mm Area (A0)= 250000.00 mm2

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-3

1-Direction Punching Check:Vt= 497.0 kN x= 905.0 mm V-eff= 641.3 kN


2-Direction Punching Check:Vt= 497.0 kN x= 1810.0 mm V-eff= 621.2 kN
Stress Check: (V-eff= 641.3 kN) v= 2.38 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 135.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 3620.0 mm Area (A)= 819024.99 mm2
1-Direction Punching Check:Vt= 484.2 kN x= 905.0 mm V-eff= 625.4 kN
Ast= 3926.99 mm2 v= 1.28 < vc=1.32 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 484.2 kN x= 1810.0 mm V-eff= 605.3 kN
Ast= 3272.49 mm2 v= 1.24 < vc=1.25 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C11 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C11 2 487.2 2.1 74.4 487.2 2.1 74.4

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 200.0 d-eff= 135.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2400.0 mm Area (A0)= 359999.99 mm2
1-Direction Punching Check:Vt= 487.2 kN x= 1005.0 mm V-eff= 490.3 kN
2-Direction Punching Check:Vt= 487.2 kN x= 1005.0 mm V-eff= 598.1 kN
Stress Check: (V-eff= 598.1 kN) v= 1.85 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 135.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 4020.0 mm Area (A)= 1.010E+06 mm2
1-Direction Punching Check:Vt= 471.4 kN x= 1005.0 mm V-eff= 474.6 kN
Ast= 4908.74 mm2 v= 0.87 < vc=1.34 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 471.4 kN x= 1005.0 mm V-eff= 582.4 kN
Ast= 4908.74 mm2 v= 1.07 < vc=1.34 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C12 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C12 2 483.4 3.2 62.5 483.4 3.2 62.5

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 200.0 d-eff= 140.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2000.0 mm Area (A0)= 250000.00 mm2
1-Direction Punching Check:Vt= 483.4 kN x= 920.0 mm V-eff= 488.6 kN
2-Direction Punching Check:Vt= 483.4 kN x= 920.0 mm V-eff= 585.3 kN
Stress Check: (V-eff= 585.3 kN) v= 2.09 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 140.0 mm Fac. Storey Load= 15.560 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 3680.0 mm Area (A)= 846399.99 mm2
1-Direction Punching Check:Vt= 470.2 kN x= 920.0 mm V-eff= 475.4 kN
Ast= 2094.40 mm2 v= 0.92 < vc=1.05 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 470.2 kN x= 920.0 mm V-eff= 572.1 kN
Ast= 2513.27 mm2 v= 1.11 < vc=1.12 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C13 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C13 2 211.7 -96.2 71.2 211.7 96.2 71.2

Column Classification: Corner

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 600.0 mm Area (A0)= 90000.05 mm2
1-Direction Punching Check:Vt= 211.7 kN x= 660.0 mm V-eff= 264.7 kN
2-Direction Punching Check:Vt= 211.7 kN x= 660.0 mm V-eff= 264.7 kN
Stress Check: (V-eff= 264.7 kN) v= 1.84 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 1320.0 mm Area (A)= 435600.10 mm2
1-Direction Punching Check:Vt= 203.5 kN x= 660.0 mm V-eff= 254.3 kN

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-4

Ast= 2513.27 mm2 v= 0.80 < vc=0.82 N/mm2 ...OK...


PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 203.5 kN x= 660.0 mm V-eff= 254.3 kN
Ast= 2513.27 mm2 v= 0.80 < vc=0.82 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C18 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C18 2 327.9 108.8 -10.1 327.9 108.8 10.1

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 800.0 mm Area (A0)= 75000.00 mm2
1-Direction Punching Check:Vt= 327.9 kN x= 1220.0 mm V-eff= 409.9 kN
2-Direction Punching Check:Vt= 327.9 kN x= 510.0 mm V-eff= 439.6 kN
Stress Check: (V-eff= 439.6 kN) v= 2.29 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2240.0 mm Area (A)= 622199.98 mm2
1-Direction Punching Check:Vt= 316.2 kN x= 1220.0 mm V-eff= 395.2 kN
Ast= 2513.27 mm2 v= 0.74 < vc=0.82 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 316.2 kN x= 510.0 mm V-eff= 424.9 kN
Ast= 2513.27 mm2 v= 0.79 < vc=0.82 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C19 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C19 2 570.7 -18.2 -18.8 570.7 18.2 18.8

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2000.0 mm Area (A0)= 249999.99 mm2
1-Direction Punching Check:Vt= 570.7 kN x= 1232.0 mm V-eff= 592.9 kN
2-Direction Punching Check:Vt= 570.7 kN x= 1232.0 mm V-eff= 593.6 kN
Stress Check: (V-eff= 593.6 kN) v= 1.22 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 4928.0 mm Area (A)= 1.518E+06 mm2
1-Direction Punching Check:Vt= 542.0 kN x= 1232.0 mm V-eff= 564.2 kN
Ast= 804.25 mm2 v= 0.47 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 542.0 kN x= 1232.0 mm V-eff= 564.9 kN
Ast= 804.25 mm2 v= 0.47 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C20 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C20 2 518.4 0.1 -17.3 518.4 0.1 17.3

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2000.0 mm Area (A0)= 249999.99 mm2
1-Direction Punching Check:Vt= 518.4 kN x= 1232.0 mm V-eff= 518.5 kN
2-Direction Punching Check:Vt= 518.4 kN x= 1232.0 mm V-eff= 539.4 kN
Stress Check: (V-eff= 539.4 kN) v= 1.11 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 4928.0 mm Area (A)= 1.518E+06 mm2
1-Direction Punching Check:Vt= 489.7 kN x= 1232.0 mm V-eff= 489.8 kN
Ast= 1005.31 mm2 v= 0.41 < vc=0.60 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 489.7 kN x= 1232.0 mm V-eff= 510.7 kN
Ast= 1005.31 mm2 v= 0.42 < vc=0.60 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C21 (Storey: 2)

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-5

================ Nd Md-1 Md-2 Vt Mt-1 Mt-2


Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C21 2 573.5 18.3 -19.3 573.5 18.3 19.3

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2000.0 mm Area (A0)= 249999.99 mm2
1-Direction Punching Check:Vt= 573.5 kN x= 1232.0 mm V-eff= 595.8 kN
2-Direction Punching Check:Vt= 573.5 kN x= 1232.0 mm V-eff= 597.0 kN
Stress Check: (V-eff= 597.0 kN) v= 1.22 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 4928.0 mm Area (A)= 1.518E+06 mm2
1-Direction Punching Check:Vt= 544.8 kN x= 1232.0 mm V-eff= 567.0 kN
Ast= 1005.31 mm2 v= 0.47 < vc=0.60 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 544.8 kN x= 1232.0 mm V-eff= 568.3 kN
Ast= 1005.31 mm2 v= 0.47 < vc=0.60 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C22 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C22 2 333.2 -109.7 -10.7 333.2 109.7 10.7

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 800.0 mm Area (A0)= 75000.00 mm2
1-Direction Punching Check:Vt= 333.2 kN x= 1220.0 mm V-eff= 416.5 kN
2-Direction Punching Check:Vt= 333.2 kN x= 510.0 mm V-eff= 448.0 kN
Stress Check: (V-eff= 448.0 kN) v= 2.33 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2240.0 mm Area (A)= 622199.98 mm2
1-Direction Punching Check:Vt= 321.5 kN x= 1220.0 mm V-eff= 401.8 kN
Ast= 2513.27 mm2 v= 0.75 < vc=0.82 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 321.5 kN x= 510.0 mm V-eff= 433.2 kN
Ast= 2513.27 mm2 v= 0.81 < vc=0.82 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C26 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C26 2 384.3 166.0 42.9 384.3 166.0 42.9

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 235.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 1200.0 mm Area (A0)= 180000.00 mm2
1-Direction Punching Check:Vt= 384.3 kN x= 1305.0 mm V-eff= 480.3 kN
2-Direction Punching Check:Vt= 384.3 kN x= 652.5 mm V-eff= 579.0 kN
Stress Check: (V-eff= 579.0 kN) v= 2.05 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 235.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2610.0 mm Area (A)= 851512.49 mm2
1-Direction Punching Check:Vt= 368.2 kN x= 1305.0 mm V-eff= 460.2 kN
Ast= 3926.99 mm2 v= 0.75 < vc=0.96 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 368.2 kN x= 652.5 mm V-eff= 558.9 kN
Ast= 3926.99 mm2 v= 0.91 < vc=0.96 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C27 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C27 2 795.9 -17.2 79.4 795.9 17.2 79.4

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-6

Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2000.0 mm Area (A0)= 250000.00 mm2
1-Direction Punching Check:Vt= 795.9 kN x= 1220.0 mm V-eff= 817.1 kN
2-Direction Punching Check:Vt= 795.9 kN x= 1220.0 mm V-eff= 893.5 kN
Stress Check: (V-eff= 893.5 kN) v= 1.86 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 4880.0 mm Area (A)= 1.488E+06 mm2
1-Direction Punching Check:Vt= 767.8 kN x= 1220.0 mm V-eff= 788.9 kN
Ast= 2094.40 mm2 v= 0.67 < vc=0.77 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 767.8 kN x= 1220.0 mm V-eff= 865.4 kN
Ast= 2094.40 mm2 v= 0.74 < vc=0.77 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C28 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C28 2 754.0 -0.5 105.2 754.0 0.5 105.2

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2400.0 mm Area (A0)= 359999.99 mm2
1-Direction Punching Check:Vt= 754.0 kN x= 1332.0 mm V-eff= 754.5 kN
2-Direction Punching Check:Vt= 754.0 kN x= 1332.0 mm V-eff= 872.5 kN
Stress Check: (V-eff= 872.5 kN) v= 1.49 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 5328.0 mm Area (A)= 1.774E+06 mm2
1-Direction Punching Check:Vt= 720.4 kN x= 1332.0 mm V-eff= 721.0 kN
Ast= 1148.93 mm2 v= 0.55 < vc=0.62 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 720.4 kN x= 1332.0 mm V-eff= 838.9 kN
Ast= 1340.41 mm2 v= 0.65 < vc=0.66 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C29 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C29 2 795.5 15.0 79.5 795.5 15.0 79.5

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 2000.0 mm Area (A0)= 250000.00 mm2
1-Direction Punching Check:Vt= 795.5 kN x= 1220.0 mm V-eff= 814.0 kN
2-Direction Punching Check:Vt= 795.5 kN x= 1220.0 mm V-eff= 893.3 kN
Stress Check: (V-eff= 893.3 kN) v= 1.86 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 4880.0 mm Area (A)= 1.488E+06 mm2
1-Direction Punching Check:Vt= 767.4 kN x= 1220.0 mm V-eff= 785.9 kN
Ast= 1795.20 mm2 v= 0.67 < vc=0.73 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 767.4 kN x= 1220.0 mm V-eff= 865.2 kN
Ast= 2094.40 mm2 v= 0.74 < vc=0.77 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C30 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C30 2 385.4 -167.6 42.7 385.4 167.6 42.7

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 1200.0 mm Area (A0)= 180000.00 mm2
1-Direction Punching Check:Vt= 385.4 kN x= 1320.0 mm V-eff= 481.8 kN
2-Direction Punching Check:Vt= 385.4 kN x= 660.0 mm V-eff= 578.8 kN
Stress Check: (V-eff= 578.8 kN) v= 2.01 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-7

Punching Zone: Perimeter (u)= 2640.0 mm Area (A)= 871199.99 mm2


1-Direction Punching Check:Vt= 368.9 kN x= 1320.0 mm V-eff= 461.2 kN
Ast= 3141.59 mm2 v= 0.73 < vc=0.88 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 368.9 kN x= 660.0 mm V-eff= 558.2 kN
Ast= 3306.94 mm2 v= 0.88 < vc=0.89 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C37 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C37 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C38 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C38 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 902500.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C39 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C39 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-8

Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...


PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C40 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C40 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 902500.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C41 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C41 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C47 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C47 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-9

2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN


Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C49 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C49 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C51 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C51 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C57 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C57 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-10

PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C59 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C59 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C61 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C61 2 0.0 0.0 0.0 0.0 0.0 0.0

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 0.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 0.0 mm Area (A0)= 0.00 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Stress Check: (V-eff= 0.0 kN) v= 0.00 < v-max=0.00 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 200.0 d-eff= 0.0 mm Fac. Storey Load= 0.000 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 0.0 mm Area (A)= 1.103E+06 mm2
>>> Warning: Column punching perimeter cannot be determined!
1-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 0.0 kN x= 0.0 mm V-eff= 0.0 kN
Ast= 0.00 mm2 v= 0.00 < vc=0.00 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C68 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C68 2 127.3 55.8 12.2 127.3 55.8 12.2

Column Classification: Corner

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 600.0 mm Area (A0)= 90000.00 mm2
1-Direction Punching Check:Vt= 127.3 kN x= 660.0 mm V-eff= 159.1 kN
2-Direction Punching Check:Vt= 127.3 kN x= 660.0 mm V-eff= 159.1 kN
Stress Check: (V-eff= 159.1 kN) v= 1.10 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 240.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 1320.0 mm Area (A)= 435600.00 mm2
1-Direction Punching Check:Vt= 119.0 kN x= 660.0 mm V-eff= 148.8 kN
Ast= 1795.20 mm2 v= 0.47 < vc=0.73 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 119.0 kN x= 660.0 mm V-eff= 148.8 kN
Ast= 1795.20 mm2 v= 0.47 < vc=0.73 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C69 (Storey: 2)

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-11

================ Nd Md-1 Md-2 Vt Mt-1 Mt-2


Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C69 2 240.3 -4.9 52.4 240.3 4.9 52.4

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 248.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 1200.0 mm Area (A0)= 174999.96 mm2
1-Direction Punching Check:Vt= 240.3 kN x= 722.0 mm V-eff= 310.6 kN
2-Direction Punching Check:Vt= 240.3 kN x= 1244.0 mm V-eff= 300.4 kN
Stress Check: (V-eff= 310.6 kN) v= 1.04 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 248.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2688.0 mm Area (A)= 898167.89 mm2
1-Direction Punching Check:Vt= 223.3 kN x= 722.0 mm V-eff= 289.4 kN
Ast= 565.49 mm2 v= 0.43 < vc=0.49 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 223.3 kN x= 1244.0 mm V-eff= 279.2 kN
Ast= 565.49 mm2 v= 0.42 < vc=0.49 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C70 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C70 2 226.8 0.0 38.9 226.8 0.0 38.9

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 1200.0 mm Area (A0)= 179999.90 mm2
1-Direction Punching Check:Vt= 226.8 kN x= 675.0 mm V-eff= 283.5 kN
2-Direction Punching Check:Vt= 226.8 kN x= 1350.0 mm V-eff= 283.5 kN
Stress Check: (V-eff= 283.5 kN) v= 0.95 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2700.0 mm Area (A)= 911249.78 mm2
1-Direction Punching Check:Vt= 209.6 kN x= 675.0 mm V-eff= 262.0 kN
Ast= 314.16 mm2 v= 0.39 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 209.6 kN x= 1350.0 mm V-eff= 262.0 kN
Ast= 314.16 mm2 v= 0.39 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C71 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C71 2 240.2 4.9 52.3 240.2 4.9 52.3

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 248.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 1200.0 mm Area (A0)= 174999.88 mm2
1-Direction Punching Check:Vt= 240.2 kN x= 722.0 mm V-eff= 310.4 kN
2-Direction Punching Check:Vt= 240.2 kN x= 1244.0 mm V-eff= 300.2 kN
Stress Check: (V-eff= 310.4 kN) v= 1.04 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 248.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2688.0 mm Area (A)= 898167.70 mm2
1-Direction Punching Check:Vt= 223.2 kN x= 722.0 mm V-eff= 289.2 kN
Ast= 565.49 mm2 v= 0.43 < vc=0.49 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 223.2 kN x= 1244.0 mm V-eff= 279.0 kN
Ast= 565.49 mm2 v= 0.42 < vc=0.49 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C72 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C72 2 127.3 -55.8 12.2 127.3 55.8 12.2

Column Classification: Corner

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-12

Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 600.0 mm Area (A0)= 90000.05 mm2
1-Direction Punching Check:Vt= 127.3 kN x= 666.0 mm V-eff= 159.1 kN
2-Direction Punching Check:Vt= 127.3 kN x= 666.0 mm V-eff= 159.1 kN
Stress Check: (V-eff= 159.1 kN) v= 1.09 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 1332.0 mm Area (A)= 443556.10 mm2
1-Direction Punching Check:Vt= 118.9 kN x= 666.0 mm V-eff= 148.6 kN
Ast= 804.25 mm2 v= 0.46 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 118.9 kN x= 666.0 mm V-eff= 148.6 kN
Ast= 804.25 mm2 v= 0.46 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C76 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C76 2 104.6 50.8 -23.4 104.6 50.8 23.4

Column Classification: Corner

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 600.0 mm Area (A0)= 90000.00 mm2
1-Direction Punching Check:Vt= 104.6 kN x= 666.0 mm V-eff= 130.8 kN
2-Direction Punching Check:Vt= 104.6 kN x= 666.0 mm V-eff= 130.8 kN
Stress Check: (V-eff= 130.8 kN) v= 0.89 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 1332.0 mm Area (A)= 443555.99 mm2
1-Direction Punching Check:Vt= 96.3 kN x= 666.0 mm V-eff= 120.3 kN
Ast= 804.25 mm2 v= 0.37 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 96.3 kN x= 666.0 mm V-eff= 120.3 kN
Ast= 804.25 mm2 v= 0.37 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C77 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C77 2 218.8 -4.4 -50.9 218.8 4.4 50.9

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 248.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 900.0 mm Area (A0)= 100000.00 mm2
1-Direction Punching Check:Vt= 218.8 kN x= 572.0 mm V-eff= 285.0 kN
2-Direction Punching Check:Vt= 218.8 kN x= 1244.0 mm V-eff= 273.5 kN
Stress Check: (V-eff= 285.0 kN) v= 1.28 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 248.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2388.0 mm Area (A)= 711568.00 mm2
1-Direction Punching Check:Vt= 205.3 kN x= 572.0 mm V-eff= 268.2 kN
Ast= 565.49 mm2 v= 0.45 < vc=0.49 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 205.3 kN x= 1244.0 mm V-eff= 256.7 kN
Ast= 565.49 mm2 v= 0.43 < vc=0.49 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C78 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C78 2 196.8 0.0 -50.2 196.8 0.0 50.2

Column Classification: Edge

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 1200.0 mm Area (A0)= 180000.00 mm2
1-Direction Punching Check:Vt= 196.8 kN x= 666.0 mm V-eff= 246.1 kN
2-Direction Punching Check:Vt= 196.8 kN x= 1332.0 mm V-eff= 246.1 kN
Stress Check: (V-eff= 246.1 kN) v= 0.84 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)

Project: ice
Project: ice - UC (*17Q-SE6Z-SJ5T-Y8JW)
COLUMN/WALL PUNCHING SHEAR REPORT Orion Building Design System 18.0 (04.2012) / Page: PCH-13

Punching Zone: Perimeter (u)= 2664.0 mm Area (A)= 887112.00 mm2


1-Direction Punching Check:Vt= 180.1 kN x= 666.0 mm V-eff= 225.1 kN
Ast= 804.25 mm2 v= 0.35 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 180.1 kN x= 1332.0 mm V-eff= 225.1 kN
Ast= 804.25 mm2 v= 0.35 < vc=0.55 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C79 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C79 2 218.3 4.4 -50.8 218.3 4.4 50.8

Column Classification: Interior

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 900.0 mm Area (A0)= 100000.00 mm2
1-Direction Punching Check:Vt= 218.3 kN x= 566.0 mm V-eff= 229.9 kN
2-Direction Punching Check:Vt= 218.3 kN x= 616.0 mm V-eff= 341.9 kN
Stress Check: (V-eff= 341.9 kN) v= 1.56 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 244.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 2364.0 mm Area (A)= 697312.00 mm2
1-Direction Punching Check:Vt= 205.1 kN x= 566.0 mm V-eff= 216.7 kN
Ast= 1005.31 mm2 v= 0.38 < vc=0.60 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 205.1 kN x= 616.0 mm V-eff= 328.7 kN
Ast= 1005.31 mm2 v= 0.57 < vc=0.60 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED

Column: 2C81 (Storey: 2)


================ Nd Md-1 Md-2 Vt Mt-1 Mt-2
Column Stry (kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
------- --- ---------- ---------- ---------- ---------- ---------- ----------
2C81 2 104.6 -50.8 -23.4 104.6 50.8 23.4

Column Classification: Corner

Punching Check: (At the Face of Loaded Area, BS8110-Cl.3.7.6.4)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u0)= 600.0 mm Area (A0)= 90000.00 mm2
1-Direction Punching Check:Vt= 104.6 kN x= 675.0 mm V-eff= 130.8 kN
2-Direction Punching Check:Vt= 104.6 kN x= 675.0 mm V-eff= 130.8 kN
Stress Check: (V-eff= 130.8 kN) v= 0.87 < v-max=4.73 N/mm2 ...OK...

Punching Check: (1. Perimeter - At 1.50d Distance, BS8110-Cl.3.7.6)


Slab: d= 300.0 d-eff= 250.0 mm Fac. Storey Load= 18.920 kN/m2 (Concrete: C35)
Punching Zone: Perimeter (u)= 1350.0 mm Area (A)= 455625.00 mm2
1-Direction Punching Check:Vt= 96.0 kN x= 675.0 mm V-eff= 120.0 kN
Ast= 314.16 mm2 v= 0.36 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED
2-Direction Punching Check:Vt= 96.0 kN x= 675.0 mm V-eff= 120.0 kN
Ast= 314.16 mm2 v= 0.36 < vc=0.42 N/mm2 ...OK...
PUNCHING REINFORCEMENT NOT REQUIRED