2. Hallar valores de E.R. , W, M, C.R.

, P, CDR

3 2

REFRIGERANTE 134-a

4 1

Estado 1

T1 = 20° C

Interpolando

20 °C 0.5728 20 °C 409,838
21 °C P1 P1 = 0.5915 MPa 21 °C h1 h1 = 410,3722 KJ/Kg
25 °C 0.6663 25 °C 412.509

Estado 2

T2 = 50 °C

Palta = 112,5 psi = 775,66 KPa Pabs = Palta + Patm = 0.877 MPa

Interpolando (vapor sobrecalentado)

0.8 MPa 435,114


0.877 h2 h2 = 433,667 KJ/Kg
0.9 MPa 433,235

Estado 3

T3 = 23° C h3 = hf

20 °C 0.5728 227,493
23 °C P3 h3 h3 = 231,7512 KJ/Kg
25 °C 0.6663 234,590 P3 = 0.6289 MPa
Estado 4

h4 = h3 =231,7512 KJ/Kg

Hallando Efecto Refrigerante ( E.R )

E.R = h1 - h4 = 178,621 KJ/Kg

Hallando Trabajo del Compresor ( W )

W = h2 - h1 = 23,2948 KJ/Kg

Hallando Masa del refrigerante ( M )

𝟏 𝑩𝑻𝒖 𝟎,𝟒𝟓𝟑𝟓𝟗𝟐𝟒
E.R = 178,621 KJ/Kg * 𝟏,𝟎𝟓𝟓𝟎𝟓𝟔 𝑲𝑱 * 𝟏 𝑳𝒃
= 76, 7932 Btu/Lb

𝟐𝟎𝟎 𝟐𝟎𝟎
M= 𝑬.𝑹. =𝟕𝟔,𝟕𝟗𝟑𝟐 =2,6044 Lb/min

Para la masa: m = M*t donde t =60 min

m = 2,6044 Lb/min * 60 min = 156,264 Lb = 70,880 Kg

Hallando Calor de Rechazo ( C.R.)

C.R. = h2 - h3 = 201, 9158 KJ/Kg

Hallando Potencia teórica del Compresor

𝟎,𝟒𝟓𝟑𝟓𝟗𝟐𝟒 𝑲𝒈 𝟏 𝑩𝑻𝒖
P = W*M = 23,2948 KJ/Kg * 𝟏 𝑳𝒃
* 𝟏,𝟎𝟓𝟓𝟎𝟓𝟔 𝑲𝑱 * 2,6044 Lb/min = 26,083 Btu/min

Hallando Coeficiente de Performance


𝑬.𝑹. 𝟕𝟔,𝟕𝟗𝟑𝟐
COP = 𝑾
= 𝟏𝟎,𝟎𝟏𝟓
= 7,668