You are on page 1of 5

Packet Tracer – Troubleshooting GRE

Topology

Addressing Table
Device Interface IP Address Subnet Mask Default Gateway

G0/0 172.31.0.1 255.255.255.0 N/A

RA S0/0/0 209.165.122.2 255.255.255.252 N/A

Tunnel 0 192.168.1.1 255.255.255.252 N/A

G0/0 172.31.1.1 255.255.255.0 N/A

RB S0/0/0 64.103.211.2 255.255.255.252 N/A

Tunnel 0 192.168.1.2 255.255.255.252 N/A

PC-A NIC 172.31.0.2 255.255.255.0 172.31.0.1

PC-B NIC 172.31.1.2 255.255.255.0 172.31.1.1

Objectives
• Find and Correct All Network Errors
• Verify Connectivity

Scenario
A junior network administrator was hired to set up a GRE tunnel between two sites and was unable to complete
the task. You have been asked to correct configuration errors in the company network.

© 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 2
Packet Tracer – Troubleshooting GRE

Part 1: Find and Correct All Network Errors.


Device Error Correction

RA G0/0 IP Address Incorrect RA(config)#interface g0/0


RA(config-if)#no ip address
RA(config-if)#ip address 172.31.0.1
255.255.255.0
RA Tunnel 0 IP Address Incorrect: RA(config)#interface tunnel 0
interface Tunnel0 RA(config-if)#no ip address
ip address 172.31.0.1 255.255.255.0 RA(config-if)#ip address 192.168.1.1
255.255.255.252

RB Tunnel 0 configured with wrong Source RB(config)#interface tunnel 0


Interface and wrong destination IP RB(config-if)#no tunnel source g0/0
Address:
RB(config-if)#no tunnel destination 192.168.1.1
tunnel source GigabitEthernet0/0 RB(config-if)#tunnel source s0/0/0
tunnel destination 192.168.1.1 RB(config-if)#tunnel destination 209.165.122.2

RA Ip route next hop incorrect: RA(config)#no ip route 172.31.1.0


ip route 172.31.1.0 255.255.255.0 255.255.255.0 64.103.211.2
64.103.211.2 RA(config)#ip route 172.31.1.0 255.255.255.0
192.168.1.2

RA#show run
Building configuration...
Current configuration : 1048 bytes
version 15.1
no service timestamps log datetime msec
no service timestamps debug datetime msec
no service password-encryption
hostname RA
ip cef
no ipv6 cef
license udi pid CISCO2911/K9 sn FTX15242579
spanning-tree mode pvst

interface Tunnel0
ip address 192.168.1.1 255.255.255.252
mtu 1476
tunnel source Serial0/0/0
tunnel destination 64.103.211.2

interface GigabitEthernet0/0
ip address 172.31.0.1 255.255.255.0
duplex auto
speed auto

interface GigabitEthernet0/1
no ip address
duplex auto
speed auto
shutdown

interface GigabitEthernet0/2
no ip address
duplex auto
speed auto
shutdown

interface Serial0/0/0
ip address 209.165.122.2 255.255.255.252

interface Serial0/0/1
no ip address
clock rate 2000000
shutdown

interface Vlan1
no ip address
shutdown

ip classless
ip route 0.0.0.0 0.0.0.0 Serial0/0/0
ip route 172.31.1.0 255.255.255.0 192.168.1.2

ip flow-export version 9

line con 0
line aux 0
line vty 0 4
login
end

RB#show run
Building configuration...
Current configuration : 1048 bytes
version 15.1
no service timestamps log datetime msec
no service timestamps debug datetime msec
no service password-encryption
hostname RB
ip cef
no ipv6 cef
license udi pid CISCO2911/K9 sn FTX152497Z4
spanning-tree mode pvst
interface Tunnel0
ip address 192.168.1.2 255.255.255.252
mtu 1476
tunnel source Serial0/0/0
tunnel destination 209.165.122.2

interface GigabitEthernet0/0
ip address 172.31.1.1 255.255.255.0
duplex auto
speed auto

interface GigabitEthernet0/1
no ip address
duplex auto
speed auto
shutdown

interface GigabitEthernet0/2
no ip address
duplex auto
speed auto
shutdown

interface Serial0/0/0
ip address 64.103.211.2 255.255.255.252

interface Serial0/0/1
no ip address
clock rate 2000000
shutdown

interface Vlan1
no ip address
shutdown

ip classless
ip route 0.0.0.0 0.0.0.0 Serial0/0/0
ip route 172.31.0.0 255.255.255.0 192.168.1.1

ip flow-export version 9
line con 0
line aux 0
line vty 0 4
login
end

Part 2: Verify Connectivity


Step 1: Ping PCA from PCB.
Attempt to ping the IP address of PCA from PCB. The ping should be successful.
C:\>ping 172.31.0.2
Pinging 172.31.0.2 with 32 bytes of data:
Request timed out.
Reply from 172.31.0.2: bytes=32 time=2ms TTL=126
Reply from 172.31.0.2: bytes=32 time=22ms TTL=126
Reply from 172.31.0.2: bytes=32 time=3ms TTL=126
Ping statistics for 172.31.0.2:
Packets: Sent = 4, Received = 3, Lost = 1 (25% loss),
Approximate round trip times in milli-seconds:
Minimum = 2ms, Maximum = 22ms, Average = 9ms
Step 2: Trace the path from PCA to PCB.
Attempt to trace the path from PCA to PCB. Note the lack of public IP addresses in the output.

Tracing route to 172.31.1.2 over a maximum of 30 hops:

1 0 ms 14 ms 0 ms 172.31.0.1
2 2 ms 15 ms 19 ms 192.168.1.2
3 10 ms 12 ms 14 ms 172.31.1.2

Trace complete.

© 2017 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 2 of 2