You are on page 1of 2

Engineering Activities for

Relocation of Fuel Gas Package in EW-2

Project No. UNP-EW-ENG-04-017 Client ELWASTANI Petroleum Company


Document No. UNP-EW-FGP-01-CAE-01 Sheet 1 of 2 Rev. A
Specification Title Cause & Effect Diagram

Cause & Effect Diagram

A 4/20/2017 Issued For Approval S.B./I.T K.H. A.A


Rev. Date DESCRIPTION Prepared Checked Approved
Engineering Activities for
Relocation of Fuel Gas Package in EW-2
Project No. UNP-EW-ENG-04-017
Document No. UNP-EW-FGP-01-CAE-01
Sheet Number 2 of 2
Definitions :

condensate line from Fuel Gas Knock

Blowdown valve on the outlet gas


stream from Fuel Gas Knock Out
Shutdown valve on the outlet
X : INPUT GIVES OUTPUT IN COLUMN(S) SHOWN
ESD : EMERGENCY SHUTDOWN ( TOTAL SHUT DOWN)

High Level Alarm


Low Level Alarm
PSD : PROCESS SHUT DOWN

Description

ESD Alarm

PSD Alarm
Out drum
CLOSE : SHUTDOWN VALVE CLOSED MEAN THAT SOV ( SOLENOID VALVE ) OF EACH VALVE SHALL BE DE -ENERGIZED.

Drum

PSD
OPEN : BLOWDOWN VALVE OPEN MEAN THAT SOV ( SOLENOID VALVE ) OF EACH VALVE SHALL BE DE -ENERGIZED.

Notes:
1- The ESD is higher level than PSD, and hence if ESD signal is generated, all effects of PSD will take place .
2- All actions will be through the compressor panel of WPS.

UNP-EW-FGP-01-PID-01

UNP-EW-FGP-01-PID-01

UNP-EW-FGP-01-PID-01

UNP-EW-FGP-01-PID-01

UNP-EW-FGP-01-PID-01

UNP-EW-FGP-01-PID-01

UNP-EW-FGP-01-PID-01
3- As per UNEPP scope of work, this cause and effect is for Fuel Gas Package only . However, It should be integrated / added with the existing cause and effect of WPS.
4- In case of high high liquid level, the effect will be process shutdown as shown in the table and it will be verified in the HAZOP.

Effects

P&ID NO

BDV-820
TAG NO

SDV-821

LAH
LAL
Action

Alarm

Alarm
Close

Open
Cause

PROCESS COMPONENT PROTECTIVE DEVICE / FUNCTION

ITEM Description P&ID No TAG No. TRIP TAG Alarm TAG Signal Description

1 ESD X X X X

2 PSD X X X

3 Fuel Gas Knock Out Drum (V-107 A) UNP-EW-FGP-01-PID-01 LT-614 LALL-614 Transmitter X

4 Fuel Gas Knock Out Drum (V-107 A) UNP-EW-FGP-01-PID-01 LT-616 LAHH-616 Transmitter X

5 Fuel Gas Knock Out Drum (V-107 A) UNP-EW-FGP-01-PID-01 LT-614 LAL-614 Transmitter X

6 Fuel Gas Knock Out Drum (V-107 A) UNP-EW-FGP-01-PID-01 LT-616 LAH-616 Transmitter X

You might also like