You are on page 1of 16

Harga koefisien hambatan ( nd )

Jenis permukaan
Permukaan impervious & licin
Tanah padat terbuka licin
Permukaan sedikit berumput, tanh debgan tanaman
berjajar, tanah terbuka kekasaran sedang
Padang rumput
Lahan dengan pohon musim gugur
lahan dengan pohon berdaun, hutan lebat
lahan berumput tebal
6.25
1.25
7.5

7.5
7.5
PERHITUNGAN DRAINASE

Luas daerah pengaliran

No Luas lahan Jenis lahan kemiringan lahan koefisien kerby C A C*A


m2 Nd (km2)
1 100 x 1000 lahan sekitar 0.06 0.4 0.3 0.1 0.03
2 15 x 1000 perkerasan 0.02 0.013 0.8 0.015 0.012
3 3 x 1000 bahu 0.04 0.2 0.4 0.003 0.0012
4 500 x 500 lahan sekitar 0.06 0.4 0.3 0.25 0.075
5 100 x 250 bahu 0.04 0.2 0.4 0.025 0.01

Total 0.393 0.1282

Perhitungan waktu konsentrasi (tc)

- Perhitungan to
to = 1.44x(nd x (l/s^0.5))^0.467
to1 = 1.44 x (0.40 x (100.00 / 0.06^0.5))^0.467 = 15.553 menit
to2 = 1.44 x (0.01 x (15.00 / 0.02^0.5))^0.467 = 1.6731 menit
to3 = 1.44 x (0.20 x (3.00 / 0.04^0.5))^0.467 = 2.41 menit

- Perhitungan Tf
V = 1.5 m/det' (beton bertulang)
Tf = 1,000.00 / 90.00 = 11.111 menit

- Perhitungan Tc
tc = 26.66 menit

Perhitungan Intensitas hujan ( I )


I = Rt/24 x (24/tc)^(2/3)
Rt = 175.5 mm
I = 104.476 mm/jam

Perhitungan debit air


Q = 1/3,6 x C x I x A Cgab = 0.3262

Q = 1/3.6 x 0.33 x 104.48 x 0.39300 = 3.4216 m3/det'

Perhitungan dimensi saluran

- saluran type persegi


direncanakan drainase dengan penampang persegi
b = 2.0 h = 2.0 A = 4 m2
Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 2.2811 m2 dengan b rencana didapatkan h cukup = 1.14 m 1.141
Tinggi jagaan W = 0.755 m

maka dimensi rencana dapat digunakan karena A rencana = 4.000 m2 > A desain = 2.281m2

- saluran type trapesium


direncanakan drainase dengan penampang trapesium n = 0.5
b = 0.7 h = 1.0 A = 1.2 m2
Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 2.2811 m2 dengan b rencana didapatkan h cukup 0.454 m 0.421
Tinggi jagaan W = 0.476 m

maka dimen rencana perlu diperbesar

Kemiringan saluran
Saluran menggunakan saluran beton precast dengan koef. Manning n = 0.01
- saluran type persegi
Dipakai b saluran = 2 m, dan h muka air = 1.141 m

V= Q/A = 1.50 m/det


R =A/ P = 0.53283 m
I = (v.n)2 / R4/3

i = 0.0005

- saluran type trapesium


Dipakai b saluran = 0.7 m, dan h muka air = 0.454 m n = 0.5
V= Q/A = 8.1295 m/det A = 0.4209 m2 P = 1.7152
R =A/ P = 0.24538 m
I = (v.n)2 / R4/3

i = 0.0430
PERHITUNGAN DRAINASE

Luas daerah pengaliran

No Luas lahan Jenis lahan kemiringan lahan koefisien kerby C A C*A


m2 Nd (km2)
1 100 x 800 lahan sekitar 0.06 0.4 0.3 0.08 0.024
2 15 x 800 perkerasan 0.02 0.013 0.8 0.012 0.0096
3 3 x 800 bahu 0.04 0.2 0.4 0.002 0.00096

Total 0.094 0.03456

Perhitungan waktu konsentrasi (tc)

- Perhitungan to
to = 1.44x(nd x (l/s^0.5))^0.467
to1 = 1.44 x (0.40 x (100.00 / 0.06^0.5))^0.467 = 15.553 menit
to2 = 1.44 x (0.01 x (15.00 / 0.02^0.5))^0.467 = 1.6731 menit
to3 = 1.44 x (0.20 x (3.00 / 0.04^0.5))^0.467 = 2.41 menit

- Perhitungan Tf
V = 1.5 m/det' (beton bertulang)
Tf = 800.00 / 90.00 = 11.111 menit

- Perhitungan Tc
tc = 26.66 menit

Perhitungan Intensitas hujan ( I )


I = Rt/24 x (24/tc)^(2/3)
Rt = 160.32 mm
I = 95.4396 mm/jam

Perhitungan debit air


Q = 1/3,6 x C x I x A Cgab = 0.3661

Q = 1/3.6 x 0.37 x 95.44 x 0.09440 = 0.7508 m3/det'

Perhitungan dimensi saluran

- saluran type persegi


direncanakan drainase dengan penampang persegi
b = 1.0 h = 1.2 A = 1.2 m2
Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 0.5005 m2 dengan b rencana didapatkan h cukup = 0.50 m 0.501
Tinggi jagaan W = 0.500 m

maka dimensi rencana dapat digunakan karena A rencana = 1.200 m2 > A desain = 0.501m2

- saluran type trapesium


direncanakan drainase dengan penampang trapesium n = 0.5
b = 0.7 h = 1.0 A = 1.2 m2
Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 0.5005 m2 dengan b rencana didapatkan h cukup 0.454 m 0.421
Tinggi jagaan W = 0.476 m

maka dimensi rencana dapat digunakan karena A rencana = 1.200 m2 > A desain = 0.501m2

Kemiringan saluran
Saluran menggunakan saluran beton precast dengan koef. Manning n = 0.01
- saluran type persegi
Dipakai b saluran = 1 m, dan h muka air = 0.501 m

V= Q/A = 1.50 m/det


R =A/ P = 0.25013 m
I = (v.n)2 / R4/3

i = 0.0014

- saluran type trapesium


Dipakai b saluran = 0.7 m, dan h muka air = 0.454 m n = 0.5
V = Q / A = 1.78383 m/det A = 0.4209 m2 P = 1.7152
R =A/ P = 0.24538 m
I = (v.n)2 / R4/3

i = 0.0021
HITUNGAN DRAINASE

Luas daerah pengaliran

No Luas lahan Jenis lahan kemiringan lahan koefisien kerby C A


m2
1 3 x 68 taman 0.04 0.2 0.8 0.000204
2 6.8 x 18.824 atap 0.577 0.02 0.8 0.000128
3 9.19 x 40.04 atap 0.577 0.02 0.8 0.000368
4 9.19 x 8.3787 atap 0.577 0.02 0.8 0.000077
5 8.7 x 28.736 taman 0.04 0.2 0.6 0.00025
6 5 x 22.8 taman 0.04 0.2 0.8 0.000114
7 18 x 50 aspal 0.0200 0.013 0.8 0.0009
8 18 x 50 aspal 0.0200 0.013 0.8 0.0009
9 8 x 48.125 atap 0.577 0.02 0.8 0.000385
10 15 x 18.733 aspal 0.0200 0.013 0.8 0.000281
0.003607

Perhitungan waktu konsentrasi (tc)

- Perhitungan to

to = 1.44x(nd x (l/s^0.5))^0.467

to1 = 1.44 x (0.20 x (3.00 / 0.04^0.5))^0.467 = 2.4053 menit


to2 = 1.44 x (0.02 x (6.80 / 0.58^0.5))^0.467 = 0.6449 menit
to3 = 1.44 x (0.02 x (9.19 / 0.58^0.5))^0.467 = 0.74 menit
to4 = 1.44 x (0.02 x (9.19 / 0.58^0.5))^0.467 = 0.7423 menit
to5 = 1.44 x (0.20 x (8.70 / 0.04^0.5))^0.467 = 3.9547 menit
to6 = 1.44 x (0.20 x (5.00 / 0.04^0.5))^0.467 = 3.0534 menit
to7 1.44 x (0.01 x (18.00 / 0.02^0.5))^0.467 = 1.8218 menit

- Perhitungan Tf

V = 1.5 m/det'

tf2 = 141.00 / 90.00 = 1.6556 menit 141


tf7 = 105.00 / 90.00 = 1.2556 menit 105
tc2-A = 2.3005 menit
tc7-A = 3.0773 menit

- Perhitungan Tc di titik B

tcA = 3.08 menit

maka dipilih tc yang dipakai adalah 3.08 menit


Perhitungan Intensitas hujan ( I )

I = Rt/24 x (24/tc)^(2/3)
Rt = 155.5 mm
- Atap
I = 390.52 mm/jam

Perhitungan debit air

Q = 1/3.6 x C x I x A

- Atap
Q = 1/3.6 x 0.80 x 390.52 x 0.00361 = 0.313 m3/det'

Perhitungan dimensi saluran

- saluran type 1
direncanakan drainase dengan penampang persegi
b = 0.4 h = 0.9 A = 0.36 m2

Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 0.2087 m2 dengan b rencana didapatkan h cukup = 0.52 m

maka dimensi rencana dapat digunakan karena A rencana = 0.360 m2 > A desain = 0.209m2

direncanakan drainase dengan penampang trapesium n = 2.5


b = 0.35 h = 0.9 A = 0.477 m2

Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 0.2087 m2 dengan b rencana didapatkan h cukup 0.4572 m

maka dimensi rencana dapat digunakan karena A rencana = 0.477 m2 > A desain = 0.209m2

Kecepatan aliran
- saluran type 1
Dipakai b saluran = 0.4 m, dan h muka air = 0.7 m

V=Q/A = 1.1179 m/det

R=A/P = 0.1556 m

Kemiringan saluran

I = ( (v.n) / R2/3 )2

i = 0.0043

Kecepatan aliran

- saluran type 1
Dipakai b saluran = 0.35 m, dan h muka air = 0.7 m n = 2.5

V=Q/A = 0.9126 m/det A = 0.343 P = 1.8039

R=A/P = 0.1901 m

Kemiringan saluran

I = ( (v.n) / R2/3 )2

i = 0.0022
0.05
0.05

861

0.0025

4.1667 3.8543 16.06


4.7917 ### ###
2/3 2/3
Rt  24  113.38  24 
I       275.13 mm/jam
24  tc  24  0.054 

0.5217 Tinggi jagaan W = 0.511 m

n = 0.209m2

0.4572 Tinggi jagaan W = 0.478 m

n = 0.209m2
0

1 2.5
X 0.5

0
n = 2 h

A = (2*b+(2*h/n))*h*0,5
P = b + ((2*(h2+(n*h)2)0,5))
PERHITUNGAN DRAINASE

Luas daerah pengaliran

No Luas lahan Jenis lahan kemiringan lahan koefisien kerby C A C*A


m2 Nd (km2)
1 100 x 1000 lahan sekitar 0.06 0.4 0.3 0.1 0.03
2 15 x 1000 perkerasan 0.02 0.013 0.8 0.015 0.012
3 3 x 1000 bahu 0.04 0.2 0.4 0.003 0.0012
4 500 x 1000 lahan sekitar 0.06 0.4 0.3 0.5 0.15
5 100 x 1000 bahu 0.04 0.2 0.4 0.1 0.04

Total 0.718 0.2332

Perhitungan waktu konsentrasi (tc)

- Perhitungan to
to = 1.44x(nd x (l/s^0.5))^0.467
to1 = 1.44 x (0.40 x (100.00 / 0.06^0.5))^0.467 = 15.553 menit
to2 = 1.44 x (0.01 x (15.00 / 0.02^0.5))^0.467 = 1.6731 menit
to3 = 1.44 x (0.20 x (3.00 / 0.04^0.5))^0.467 = 2.41 menit

- Perhitungan Tf
V = 1.5 m/det' (beton bertulang)
Tf = 1,000.00 / 90.00 = 11.111 menit

- Perhitungan Tc
tc = 26.66 menit

Perhitungan Intensitas hujan ( I )


I = Rt/24 x (24/tc)^(2/3)
Rt = 163.88 mm
I = 97.5589 mm/jam

Perhitungan debit air


Q = 1/3,6 x C x I x A Cgab = 0.3248

Q = 1/3.6 x 0.32 x 97.56 x 0.71800 = 5.8373 m3/det'

Perhitungan dimensi saluran

- saluran type persegi


direncanakan drainase dengan penampang persegi
b = 2.0 h = 2.0 A = 4 m2
Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 3.8915 m2 dengan b rencana didapatkan h cukup = 1.95 m 1.946
Tinggi jagaan W = 0.986 m

maka dimensi rencana dapat digunakan karena A rencana = 4.000 m2 > A desain = 3.892m2

- saluran type trapesium


direncanakan drainase dengan penampang trapesium n = 0.5
b = 0.7 h = 1.0 A = 1.2 m2
Vr = 1.5 m/det'

hasil perhitungan didapatkan :


A = Q / vr = 3.8915 m2 dengan b rencana didapatkan h cukup 0.454 m 0.421
Tinggi jagaan W = 0.476 m

maka dimen rencana perlu diperbesar

Kemiringan saluran
Saluran menggunakan saluran beton precast dengan koef. Manning n = 0.01
- saluran type persegi
Dipakai b saluran = 2 m, dan h muka air = 1.946 m

V= Q/A = 1.50 m/det


R =A/ P = 0.66053 m
I = (v.n)2 / R4/3

i = 0.0004

- saluran type trapesium


Dipakai b saluran = 0.7 m, dan h muka air = 0.454 m n = 0.5
V= Q/A = 13.869 m/det A = 0.4209 m2 P = 1.7152
R =A/ P = 0.24538 m
I = (v.n)2 / R4/3

i = 0.1252