Data Sheet : Induction Motor

s Champion Series
Motor Type : 1LA2 113-4NA80
Number of Phases 3
Rated Output kW 3.7
Rated Voltage V 415
Rated Current A 7.6 Reference Standard IS:12615
Rated Speed rev/min 1460 Enclosure IS:4691 IP55
Rated Frequency Hz 50 Cooling IS:6362 IC411
Rated Torque 2.5 kgf.m / 24 Nm Duty S1
100% load % 88.4 Type 1XB0 132
Efficiency : 75% load % 88.4 Terminal Terminal Size M5
50% load % 87.4 Box No. of Terminals 6
100% load % 0.77 Data Max. Cable
Power Factor : 75% load % 0.68 Section mm 2R 3C 16mm
50% load % 0.58 Drive End 6206ZZ
Insulation Class F Non-Drive End 6206ZZ
Bearing
Temperature rise (Res.method) K 70
Data
Lubrication Pre-Lubricated
Life L10 hrs. # 50,000
Locked rotor Hot (s) 5 Lifting eyebolt IS:4190 M8
withstand time Cold (s) 12 Motor weight (approx.) kg 43
Stator connection DELTA GD (4x MI) kgf.m 0.0404
Rotor
Rotor Class KL16 Weight kg 17.2
Construction IS:2253 IMB3
Ratio of starting
current to the 100% voltage 7.5 Frame designation 112M
rated current 80% voltage 5.6
Ambient Temperature C 50
Ratio of starting Voltage Variation % 10
torque to the 100% voltage 3.0 Frequency variation % 5
rated torque 80% voltage 1.7 Combined Voltage &
Frequency variation % 10
Ratio of Breakdown # For directly coupled drives
torque to the 100% voltage 4.0
rated torque 80% voltage 2.4 Data subject to tolerance as per IS:12615.

Remarks : Unique Identification Code: UIC-2172985 <--- This code must match with the one on Characteristic Curves Sheet.

KALWA, INDIA Reference Document Printed & Checked : Release Date


Department : I DT LD P LV-Motors MTR 2.6-182 Date : 14.12.2012 Aug '2011
Format Reference No.: MTR 7.1-006

Program Name:Documentation_Program_IE_V3_2R
s Characteristic Curves
Unique Identification Code: UIC-2172985 <--- This code must match with the one on the Data Sheet.

Motor Type : 1LA2 113-4NA80 Voltage : 415V Rated Speed : 1460 rev/min
Output : 3.7 kW Frequency : 50Hz Rated Torque : 2.5 kgf.m / 24 Nm
Rated Current: 7.6A

% Load FL FL FL Locked Rtr Curr 7.5 x Rated


Efficiency 88.4% 88.4% 87.4% LRWT HOT 5s
Power Factor 0.77 0.68 0.58 LRWT COLD 12 s

D A T A S U B J E C T T O T O L E R A N C E A S P E R I S : 1 2 6 1 5.

Efficiency & PF Curves Current Vs Load Curve

1 8
0.9 7

0.8 6

Current in A
5
0.7
Eff, PF

4
0.6
3
0.5
2
0.4 1
0.3 0
40 50 60 70 80 90 100 40 50 60 70 80 90 100
Load (% of rated output) Load (% of rated output)

Effy PF Current

Values other than those at FL, FL and FL are only indicative. Do not extrapolate to No-load.

Speed Torque Curve Locked Rotor Withstand Curve


[Applicable for operation of motors on Grid Supply only.] [Applicable for operation of motors on Grid Supply only.]

450 100000

400

350 10000
Torque (% of rated)

300
1000
250
Time (s)

200
100
150

100
10
50

0
0 20 40 60 80 100 1
0 1 2 3 4 5 6 7 8
Speed (% of synchronous)
Current (times the rated)

Torque at 100%Vr Torque at 80% Vr Hot Cold

KALWA, INDIA Reference Document Printed & Checked : Release Date


Department : I DT LD P LV-Motors MTR 2.6-182 Date : 14.12.2012 Aug '2011

Program Name: Documentation_Program_IE_V3_2R