On the nose
Its an unmistakable aroma Providing compactors and bins with issue. Indeed, in most cases after applying
appropriate covers/lids these machines, the scent is a mixture of
and one that your tenants Applying lids on the top of the compactors garbage and perfume.
will have plenty to say about. can also be very effective. Covers capture Deploying odour control technologies
the gas before it is released into the area. using photolysis, oxidation, ozonolysis
ARIAN BAHRAMSARI Upholding bin chutes exhaust fans and catalysts
reports. Maintaining exhaust fans mounted in the There are numerous forms of odour
vent stack, which create a partial vacuum removal machines on the market using
in the chute and extract fumes and odours, these methods. Some systems use a
is also an imperative consideration to single-engineered technique, while others

A
n unpleasant smell emanating remove smells. These fans are normally apply a combination of methods.
from garbage rooms, bin chutes located on the roof of the building and a
and loading bay areas is not the weatherproof cowl is generally fitted at the ODOUR CONTROL
lingering impression you want top of the vent stack. TECHNOLOGIES
to give to residents, visitors or clients. It can Creating negative pressure in garbage Ultraviolet germicidal irradiation
also lead to disputes between neighbours rooms via HVAC (heating, ventilation and technology
and even some allergic problems for air-conditioning) optimisation In this method the air is forced through
building occupants. Tune up the trash rooms ventilation ultraviolet (UV) germicidal irradiation.
According to environmental campaigner, system and confirm that adjacent areas Essentially, UV light is a short-wavelength
author, broadcaster, science journalist are positively pressurised in relation to the light just beyond the blue/violet part of the
and sustainability researcher Tanya Ha, odour source. The constant exhaust can electromagnetic spectrum that our eyes can
Australians produce about 2.25 kilograms of create a negative pressure in the garbage detect. UV is classified into three wavelength
waste each per day. Imagine a high-rise tower room, chute and shafts. The negative ranges:
with around 500 apartments that means pressure would prevent odour migration UV-C, from 100 nanometres to 280
more than a tonne of rubbish produced in a back into the halls and outside of the nanometres (called germicidal UV)
day. Odour control management needs to be garbage room. A well-maintained HVAC UV-B, from 280 nanometres to 315
more than simply installing an automated air system can also stop dust blowing out into nanometres, and
freshener in garbage rooms and bin chutes. the faces of residents/clients/cleaners UV-A, from 315 nanometres to 400
when they open the chute to dispose nanometres.
ODOUR REMOVAL RESOLUTIONS of garbage. Facility managers should UV-C or germicidal UV (usually around
From simple proactive steps to sophisticated also note that the air transported by 250 nanometres) is the most effective
resolutions, there are several approaches mechanical ventilation systems can move bandwidth of UV light in destroying
that facility managers can use to overcome odours from their source into an area microorganisms in the air. In this way, UV light
odour challenges. where people complain. can damage the DNA structure and chemical
Prevention is obviously the best step. Here Installing a garbage cooler system bonds of volatile organic compounds (VOCs),
are some common and effective tactics to Cooling systems usually maintain the which cause odours.
successfully manage garbage smell: garbage storage areas temperature The hindmost step of this method could be
Arranging more frequent service from the below 10 degrees Celsius and they will an appropriate filtration, which removes the
bin hauler company slow down odorous molecules activity microorganisms and dead remains.
Although it may seem obvious to some, dramatically. Having said this, while cooling There are two major reasons that
scheduling frequent trips from your systems may partially rectify the odour justify applying filters with UV-C odour
garbage hauling party, regardless of problem, nevertheless their maintenance control systems. First, according to an
compactors being full or not, can make a cost and energy consumption can leave a article published in 2015 in the journal,
great difference. lot to be desired. Environmental Science and Technology, UV
Frequent sanitising in targeted area Installing air freshener units treatment alone can push bacteria into a
Regularly disinfecting, sterilising and It may seem the quickest and easiest way dormant state instead of killing them, and
cleaning trash chutes, compactors and to neutralise trash odours, but its not the in some cases, the bacteria can later revive
other waste receptacles can minimise right way to go. There is a wide range and proliferate. Second, dead organisms may
negative impacts of bad smells and of perfume dispersal equipment in the become food for new produced bacteria and
improve comfort and enjoyment of a space. market, but such products only mask the airborne particles.