You are on page 1of 14

ENSAYOS DE LABORATORIO DE MECANICA DE SUELOS Y PAVIMENTOS

ASESORAMIENTO TECNICO EN MECANICA DE SUELOS Y GEOTECNIA

ANALISIS GRANULOMETRICO POR TAMIZADO (VIA SECA) - ASTM


PROYECTO:

Ubicacin:
Lugar:
Fecha:
Calicata N: Prof. Muestra N :
Clculos:

Peso de la Muestra Seca 3986.00 gr


3235.00 gr
3235
Tamiz Diam(mm) Peso Ret. Peso Corr. % Ret. % Pasa
3" 73.2 0.00 0.00 0.00 100.00
2" 50.8 0.00 0.00 0.00 100.00
1 1/2" 38.1 100.00 100.00 2.51 97.49
1" 25.4 446.00 446.00 11.19 86.30
3/4" 19.05 358.00 358.00 8.98 77.32
1/2" 12.7 338.00 338.00 8.48 68.84
3/8" 9.53 207.00 207.00 5.19 63.65
1/4" 6.35 379.00 379.00 9.51 54.14
4 4.75 228.00 228.00 5.72 48.42
10 1.9 345.00 345.00 8.66 39.76
20 0.84 82.00 82.00 2.06 37.71
30 0.59 70.00 70.00 1.76 35.95
40 0.45 121.00 121.00 3.04 32.92
60 0.25 116.00 116.00 2.91 30.01
100 0.15 379.00 379.00 9.51 20.50
200 0.075 61.00 61.00 1.53 18.97
cazuela 0 3.00 756.00 18.97 0.00
3233.00 3986.00 100
Material Perdido 2.00 gr.
Porcentaje de Perdida 0.06 %

Curva Granulometrica

100
% Que Pasa

80

60

40

20 Calicata C - (8 ) Prof. 1.50


% Que
80

60

40

20 Calicata C - (8 ) Prof. 1.50


m.

0
100 10 1 0.1
Diametro de Tamices en m.m.
RATORIO DE MECANICA DE SUELOS Y PAVIMENTOS
NTO TECNICO EN MECANICA DE SUELOS Y GEOTECNIA

O POR TAMIZADO (VIA SECA) - ASTM D421-58

D60 = 8.31
D30 = 0.30
D10 = No Existe

Cu = No Existe
Cc = No Existe

va Granulometrica
1 0.1 0.01
Diametro de Tamices en m.m.
ENSAYOS DE LABORATORIO DE MECANICA DE SUELOS Y PAVIMENTOS
ASESORAMIENTO TECNICO EN MECANICA DE SUELOS Y GEOTECNIA

CONTENIDO DE HUMEDAD
PROYECTO:

Ubicacin:
Lugar:
Fecha:
Calicata N: Prof. Muestra N :
Clculos:

ENSAYO 1 2 3
Cpsula N C-11 C-12 C-13
Peso suelo hmedo + cpsula 156.00 145.00 147.90
Peso suelo seco + cpsula 146.00 136.00 139.00
Peso del agua 10.00 9.00 8.90
Peso de la cpsula 34.20 34.30 36.00
Peso neto del suelo seco 111.80 101.70 103.00
% de Humedad 8.94% 8.85% 8.64%

W (%) = 8.73%

OBSERVACIONES :
NTOS

4
C-14
113.20
107.00
6.20
34.00
73.00
8.49%
ENSAYOS DE LABORATORIO DE MECANICA DE SUELOS Y PAVIMENTOS
ASESORAMIENTO TECNICO EN MECANICA DE SUELOS Y GEOTECNIA

LIMITES DE CONSISTENCIA ASTM 423-66 Y ASTM D424-59

PROYECTO:

Ubicacin:
Lugar:
Fecha:
Calicata N: Prof.
Clculos:

LIMITE LIQUIDO
Muestra 1 2 3
N de Cpsula 1 2 3
Caps.+ S. hmedo 59.80 61.50 64.50
Caps.+ S. seco 55.20 56.30 59.00
Agua 4.60 5.20 5.50
Peso Cpsula 36.20 34.10 34.10
Peso S. seco 19.00 22.20 24.90
% Humedad 24.21 23.42 22.09
N de golpes 14 18 23
2.6390573296 2.8903717579 3.1354942159
LIMITE PLSTICO
Muestra 1 2 3
N de Cpsula 20 24 25
Caps.+ S. hmedo 15.30 15.40 15.60
Caps.+ S. seco 14.40 14.40 14.50
Agua 0.90 1.00 1.10
Peso Cpsula 7.60 7.60 7.50
Peso S. seco 6.80 6.80 7.00
% Humedad 13.24 14.71 15.71

LIMITE LiQUIDO= 21.66 %


LIMITE PLASTICO= 14.59 %
INDICE DE PLASTICIDAD (%) = 7.07 %

LIMITE LIQUIDO
HUMEDAD (%)

30.00
29.00
28.00
27.00
26.00
25.00 24.21
24.00 f(x) = -4.669830982
23.42 l n(x) + 36.6883755373

23.00
22.09
22.00 21.18
27.00
26.00
25.00 24.21
24.00 f(x) = -4.669830982
23.42 l n(x) + 36.6883755373

23.00
22.09
22.00 21.18
21.00
10 NUMERO DE GOLPES 100
MENTOS
NIA

ASTM D424-59

Muestra N :

4
4
64.90
59.50
5.40
34.00
25.50
21.18
27
3.295836866

4
26
15.30
14.30
1.00
7.50
6.80
14.71
100
ENSAYOS DE LABORATORIO DE MECANICA DE SUELOS Y PAVIMENTOS
ASESORAMIENTO TECNICO EN MECANICA DE SUELOS Y GEOTECNIA

CLASIFICACIN DE SUELOS AASHTO 1971 Y SUCS


PROYECTO:

Ubicacin:
Lugar:
Fecha:
Calicata N: Prof. : Muestra N :
Clculos:

ITEM PROPIEDAD RESULTADO DE ENSAYOS

01.01 % QUE PASA EL TAMIZ N4 48.42


01.02 % QUE PASA EL TAMIZ N10 39.76
01.03 % QUE PASA EL TAMIZ N40 32.92
01.04 % QUE PASA EL TAMIZ N100 20.50
01.05 % QUE PASA EL TAMIZ N200 18.97
01.06 COEFICIENTE DE UNIFORMIDAD No Existe
01.07 COEFICIENTE DE CONCAVIDAD No Existe
01.08 INDICE DE GRUPO (%) 0
02.01 LIMITE LIQUIDO (%) 21.66
02.02 LIMITE PLSTICO (%) 14.59
02.02 NDICE DE PLASTICIDAD (%) 7.07
03.01 HUMEDAD NATURAL(%) 8.73%
CLASIFICACIN AASHTO A-2-4
CLASIFICACIN SUCS GC

CONCLUSIONES:
TOS
NIA

1 Y SUCS

ULTADO DE ENSAYOS

48.42 ###
39.76 ###
32.92
20.50
18.97
No Existe
No Existe
0
21.66
14.59
7.07
8.73%
A-2-4
GC
ENSAYOS DE LABORATORIO DE MECANICA DE SUELOS Y PAVIMENTOS
ASESORAMIENTO TECNICO EN MECANICA DE SUELOS Y GEOTECNIA

DETERMINACIN DE LA CAPACIDAD DE CARGA

PROYECTO: ESTUDIO DE ASENTAMIENTOS DIFERENCIALES

Ubicacin: ABANCAY APURIMAC


Lugar: URB. SEGIO URBIOLA-FONAVI
Solicitante: GRUPO 2
Fecha:
Pozo N: C-01 Prof. 1.50 m. Muestra N : 01
Clculos:

PROPIEDAD DE MATERIAL SIMBOLO VALOR


COHESION C 0.35
COHESION CORREGIDO - C= (2/3)C C 0.23
PESO ESPECIFICO DEL SUELO gnat 1.85
PROFUNDIDAD DE DESPLANTE Df 1.50
LONGITUD MINIMA DE CIMENTACION (ancho) B 1.20
ANGULO DE FRICCION INTERNA 29.50
ANGULO DE FRICCION INTERNA CORREGIDO =arcTg(2/3Tg) 20.67
Nq 6.84
FACTORES DE CAPACIDAD DE CARGA Ng 5.92
Nc 15.48

1
qc cN c g D f N q g BN g
2
qc = 23.36
qc
qadm F.S= 3
F.S.
qadm= 7.79
qadm= 0.78

OBSERVACIONES :
ARGA

UNIDAD

Tn/m2
Tn/m3
Tn/m3
m
m

Tn/m2

Tn/m2
Kg/cm2

You might also like