TAURUS MAX- 3 EHF Overhead EHV AC Transmission line Analyzer is a state of the art
offline portable kit, capable of detecting accurately any fault on EHV Transmission lines
and also helps you to venture beyond, into innovative line signature analysis study, useful
in predictive maintenance of Transmission lines.
Need of the hour : The currently employed online measuring systems, part of the
protective relay apparatus, is executed in real time and designed to trade off accuracy for
speed of decision making. Need of high accuracy and dependability to detect the faulty
tower is increasingly gaining importance as the demand is increasing to achieve a near
100% uptime. A stand alone, portable, offline kit capable of finding fault accurately to the
tower (non system based, non stress affected), is required not only to accurately find
faults, but also to declare line healthy after a short duration of sustained transient fault
avoiding rigorous patrolling. A signature analysis study of the transmission line as an
extended feature, will help the operation and maintenance team enormously in
understanding their line better.

Description
The Max-3 EHF is a revolutionary innovative system
significantly minimizes the transmission line downtime and
overall line maintenance time. Max-3 EHF is the third
generation, one of its kind product that works on the principle of
multiple pulse echo co-relation technique, using advanced
matrix processors. A single system offers a cost effective
monitoring of all AC overhead de- energized lines from 66kV to
800kV, providing accurate information on all faults and line
signature analysis, which give data of all inhomogeneous points.

Advantages
Offline Fault Location
New

Overhead EHV AC Transmission Line Signature Analysis


Incorporates automatic sag & jumper compensation.
Line Healthiness Analysis and diagnosis
Trivial frequency analysis to have insight into line healthiness.
Commissioning of new Overhead Transmission Line Better graphic resolution in EHF mode.

Virtual Line Patrolling


Predicts inhomogeneous points

Attaining Optimum Transmission line availability


Effective Maintenance of Transmission System
All types of faults & inhomogeneities in line will be located accurately in very short time
An ISO 9001 : 2008 Company

www.tauruspowertronics.com
Salient Features
Fault & line diagnostics - Fault information and distance to fault in direct reading digital data display in kms and a
comprehensive line signature Analysis and diagnosis.
Flexibility in utility and application - Portable system that can be used on any de-energised line from 66kv to
800kV AC lines.
Auto calibrated system - Requires no parameter input or presetting. Extremely simple operation.
Direct reading digital display - No interpretation required.
Fault resolution - +/- 100 meters through out the range of 1000 kilometers.
Line signature Analysis - Reveals all the inhomogeneties prevalent along the transmission line. Serial
comparison of this data enables the user to infer deteriorating points along the line which could be the cause of
power loss, frequent tripping and eventual line breakdown.
Zoom blanking - Unique capability to easily detect faults in spur lines and other applications with extended range
blanking facility.
Direct PC storage - No cumbersome interfacing modules to storage units, Review and print only selected frames
/ data.
Optimum safety - Engineered both in design and hardware with added safely mechanisms to ensure total safety
of the operating personal. Splash proof connector ensures firm interconnections between the system
constituents. Complete suppression of stray surges, lightning impact and induction voltages from parallel feeders.
EHT Line Simulator - For ascertaining the systems functional aspects. Also serves as an ideal training kit.
TADMA - TAURUS data management software for instantaneous LSA data management - Using TADMA, Line
Signature Analysis and its inhomogeneties are automatically tabulated and printed / stored. TADMA
instantaneously computes, documents, initiated its diagnostic s/w, classifies and interprets LSA line study.
Customized reference to each & every line including tower schedules (opt).
All weather system - Hardware performs efficiently without loss of accuracy between - 20C to 60C.
Portable off-line - System with in built re- chargeable batteries.

Specifications
Range : up to 1000kms
Signature analysis : Every 100m with accurate results
Operating temperature : -20C to 60C
Fault detection : All types of 'OPEN' faults, 'SHORT' faults and faults on spur lines
Power Supply : 15VDC and Built-in rechargeable battery
Display : High resolution illuminated LCD display
Outputs : Printout in 4 formats, Graphic LCD display & Complete Analysis data to Laptop loaded
with TADMA Software
Type of Signal Transmission : Pulse EHF, HF & LF options
Control : Automatic mode and Manual mode

TAURUS POWERTRONICS PVT LIMITED Delhi Office : No. 712, 7th Floor, Building No. C-9 Pearls
Best Heights - II Netaji Subhash Place, Pitampura,
Corporate Office : No. 26, Mahadimane, 12th Main, 1st Block, Rajajinagar, Bangalore - 560 010. D e l h i - 11 0 0 3 4 . I N D I A . P h : 0 11 - 4 7 2 9 2 2 7 4
INDIA. Tel : + 91 80 23012301 Fax : 91 80 23327736 Email : info@tauruspowertronics.com South Africa Office : 10 Banff Street, Blue Valley Golf Estate
Sales & Service Office : No. 648/54, KLE College 2nd Block, Rajajinagar, Bangalore - 560 010. Centurion 0157. Tel : + 27 11 5120100 Fax : + 27 11 5120101
An ISO 9001 : 2008 Company INDIA Tel : + 91 80 2352 2136 / 74. E - mail : info@taurus.co.sa

You might also like