You are on page 1of 20

Emergency stop rope pull

switches
Preventa XY2C
Catalogue
Contents Emergency stop rope pull
switches Preventa XY2C

Emergency stop rope pull switches Preventa XY2C


General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 2 to 4
Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5 1
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
XY2CH order form. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
XY2CE order form. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
Separate components references. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
Mounting accessories and kits references. . . . . . . . . . . . . . . . . . . . . . . . page 9
Replacement parts references. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
2
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11

Rope pull switches Preventa XY2CB


Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rope pull switches references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 12
page 13
3
Separate components and replacement parts references. . . . . . . . . . . page 14
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15

Product reference index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16 4

10

1
General Safety detection solutions
Emergency stop rope pull switches
Preventa XY2C

Presentation Emergency stop rope pull switches


Emergency stop rope pull switches are designed to:
1 b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which could cause injury
to persons or damage either to machines or work in progress,
b be tripped by a single human action when a normal Emergency stop function is not available,
b trip in the event of the rope pull breaking.

Emergency stop rope pull switches are essential in premises and on machines that are potentially dangerous when in
operation. The operator must be able to trigger the stop instruction at any point within their working area.
2 Application examples: woodworking machines, shears, conveyor systems, transfer machines, printing machines, textile
machines, rolling mills, test laboratories, paint shops, surface treatment works.

Installation Typical installation

6 1 2 3 4 5

7 8 7 6 1
1 Fixing support 4 Pulley supports and pulleys 7 Switch adjustment
2 First cable support 5 End spring 8 Emergency stop
3 Turnbuckle 6 Cable grips
Notes regarding installation
8 b All XY2CH and XY2CE emergency stop rope pull switches can be fitted with a pilot light to indicate their tripped
condition.
b Cable tension adjustment can be performed using:
v a turnbuckle (to be ordered separately, see page 9),
v a tensioner (integrated in certain XY2CH models, see page 9).
b This adjustment is simplified by:
v a cable tension indicator that is available on all models XY2CH,
9 v the availability of versions with a cable tension indicator window by stating its reference on the order form
(see page 8). Example: reference XY2CE1A250 becomes XY2CE1D250.
b The use of an end spring is strongly advised for conveyor system applications to ensure operation of the
Emergency stop in the event of the cable being pulled towards the switch.
b It is essential that pulleys be used with ropes pull that deviate from a straight run, i.e. angled to form a protected
zone.
b Important: emergency stop rope pull switches XY2CH and XY2CE can be used if the installation requires that the
10 rope pull be angled.
In this case, the total sum of the angles through which the rope pull bends must not exceed 180.
(For further information on instructions to be adhered to, please refer to the installation manual).

Characteristics: References: Dimensions:


page 5 page 6 page 11

2
General (continued) Safety detection solutions
Emergency stop rope pull switches,
Preventa XY2C

Main features
1 2 3
1
Positive operation: running 1 The switches incorporate positive opening operation contacts, the
condition tripping of the switch being made with positive action.
Latching: stop instruction given 2 The switch latches in the tripped position (NC safety contact(s) open).
(tripped) The function of the NO contact is purely for signalling.
Resetting: stop condition
(awaiting reset/restart)
3 The switches incorporate a reset button, which re-closes the safety
contact(s). Restarting of the machine must only be achieved by manual 2
operation of a control device within the machine start circuit, remote to the
emergency stop rope pull switches.

Rope pull expansion Temperature variations likely to be encountered in the protected zone will obviously cause the rope pull to
and contraction: d expand or contract.
To enable instant verification that the rope pull is at its correct tension (and for making any necessary
adjustments), emergency stop rope pull switches XY2CH and XY2CE incorporate a rope pull tension indicator. 3

d (mm) 4

5
Standards Emergency stop rope pull switches Preventa XY2CH and XY2CE meet all the requirements of the harmonised
European standard EN/ISO 13850, relating to Emergency stop devices.
All the emergency stop rope pull switches are e marked and supplied with an EC declaration of conformity.
6
Cables diameter In order to achieve the maximum cable length, according to ambient temperature variation, we recommend
to use :
b galvanised cables with red sheath diametre 3.2 mm for XY2CH range and
b galvanised cables with red sheath diameter 5 mm for XY2CE range (see page 9).

10

3
General (continued) Safety detection solutions
Emergency stop rope pull switches
Preventa XY2C

Adjustment values For emergency stop rope pull switches XY2CE, the adjustment values depend on the positions of the cam
located inside the switch. The adjustment is made by rotating the cam after the switch has been installed.
(with end spring)
1 Each notched of the cam is referenced by the letters A to F and the selected letter is visible through a viewing
port.

The use of an end spring is strongly advised, so you can see the references in the table below regarding each
type:

Type Position of cam Maximum length of cable End spring

2 XY2CH
XY2CE

A, B, C, D, E, F
30 meters
70 meters
XY2CZ703
XY2CZ702

XY2CH
100
90
80

3 70
60
50
T (C) 40
30
20
10

4 0 5 10 15 20 25 30 m

L (m)

With the graph above, if we consider an ambient temperature variation of 25C, for example from

5 0C to + 25C, the table gives us a maximum cable length of 30 meters.

XY2CE
100 AB CDE F
90
80
70
6 60
50
40
T (C) 30
20
10
0

7
5 10 15 20 25 30 35 40 45 50 55 60 65 70 m

L (m)

With the graph above, if we consider an ambient temperature variation of 35C, for example from

8 - 10C to + 25C, the table gives us a maximum cable length of :


b 40 meters with cam A adjustments,
b 70 meters with cam F adjustments.

10

Characteristics: References: Dimensions:


page 5 page 6 page 11

4
Characteristics Safety detection solutions
Emergency stop rope pull switches
Preventa XY2C

Environment
Conformity to standards Products XY2CH, XY2CE: EN/IEC 60947-5-5, EN/ISO 13850: 2006, UL508

Machine assemblies
and CSA C 22-2 n 14 (with suffix H7)
XY2CH, XY2CE: EN/IEC 60204-1, Machinery directive: 2006/42/EC, 1
Work equipment directive: 2009/104/EC
Product certifications XY2CH, XY2CE: UL-CSA (with suffix H7), CCC (1)
Maximum safety level (2) PL e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
Reliability data B10d XY2CH: 4,000,000
XY2CE: 50,000
(data values for a service life of 20 years: can be limited by contact and mechanical wear)
Protective treatment Standard version
Special version
TC
TH
2
Ambient air temperature For operation - 25+ 70 C
For storage - 40+ 70 C
Vibration resistance XY2CH: 10 gn (10150 Hz)
XY2CE: 10 gn (10300 Hz) conforming to EN/IEC 60068-2-6
Shock resistance XY2CH, XY2CE: 50 gn (duration 11 ms) conforming to EN/IEC 60068-2-27
Electric shock protection
Degree of protection
Class I conforming to IEC61140
XY2CH, XY2CE: IP65 conforming to IEC 60529 (IP66 for XY2CEpA1pp, XY2CEpA2pp
3
and XY2CEpA3pp)
Mechanical life XY2CH: 800,000 operating cycles
XY2CE: 10,000 operating cycles
Length of protected zone (rope pull) XY2CH: y 30 metres, XY2CE: y 70 metres
Distance between cable supports 5m

4
Cable entries XY2CH: tapped entries with Pg 13.5, ISO M20 or 1/2 NPT.
XY2CE: plain holes for Pg 13.5, ISO M20 or 1/2 NPT.
See dimensions, page 11.
Contact block characteristics
Rated operational 2-pole contacts XY2CH, XY2CE:
characteristics AC-15: A300 or Ue = 240 V, le = 3 A
DC-13: Q300 or Ue = 250 V, le = 0.27 A, conforming to EN/IEC 60947-5-1 Appendix A
3-pole contacts XY2CH, XY2CE:
AC-15: C300 or Ue = 240 V, le = 0.75 A
DC-13: R300 or Ue = 250 V, le = 0.1 A, conforming to EN/IEC 60947-5-1 Appendix A 5
Nominal thermal current 10 A
Rated insulation voltage 2-pole contacts XY2CH, XY2CE: Ui = 500 V degree of pollution 3 conforming to EN/IEC 60947-1,
Ui = 300 V conforming to UL 508, CSA C22-2 n 14
3-pole contacts XY2CH, XY2CE: Ui = 400 V degree of pollution 3 conforming to EN/IEC 60947-1,
Ui = 300 V conforming to UL 508, CSA C22-2 n 14

6
Rated impulse withstand 2-pole contacts XY2CH, XY2CE: Uimp = 6 kV conforming to EN/IEC60947-1
voltage 3-pole contacts XY2CH, XY2CE: Uimp = 4 kV conforming to EN/IEC60947-1
Positive operation NC contact with positive opening operation conforming to EN/IEC60947-5-1 Section3
Contact operation XY2CH, XY2CE (Emergency stop)
Resistance across terminals y 25 m conforming to NF C 93-050 method A or EN/IEC 60255-7 category 3
Terminal referencing Conforming to CENELEC EN 50013
Short-circuit protection 2-pole contacts XY2CH, XY2CE: 10 A cartridge fuse type gG (gl) conforming to IEC 60269

7
3-pole contacts XY2CH, XY2CE: 6 A cartridge fuse type gG (gl) conforming to IEC 60269
Rated operational power XY2CH, XY2CE
(Electrical durability) Conforming to EN/IEC 60947-5-1 Appendix C. Utilisation categories AC-15 and DC-13
Operating rate: 3600 operating cycles/hour. Load factor: 0.5
AC supply a 50/60 Hz 2-pole contacts 3-pole contacts
o Inductive circuit 5 Ithe
5
Millions of operating cycles

Millions of operating cycles

4 Ithe 4
3 3
230 V 12/24/48 V
2

1
110 V
2
230 V
12/24/48 V
110 V
8
1

0,5 0,5

0,2 0,2

0,1
0,5 1 2 3 4 5 10
0,1
0,5 1 2 3 4 5 10
9
Current in A Current in A
DC supply c Voltage V 24 48 120 Voltage V 24 48 120
Power broken in W for 1 million o W 13 9 7 o W 4 3 2
operating cycles
o inductive circuit

Contact connection Screw clamp terminals


Clamping capacity: min. 1 x 0.5 mm2, max. 2 x 1.5 mm2
10
Minimum tightening torque: 0.8 N.m. Maximum tightening torque: 1.2 N.m
(1) Only products XY2CH without pilot light are CCC and UL-CSA approved.
(2) Using an appropriate and correctly connected control system.

5
References Safety detection solutions
Emergency stop rope pull switches
Preventa XY2C

Latching Emergency stops


(Pg 13.5, integrated turnbuckle, cable and end spring to be ordered separately) (1)
1 Without pilot light
Length Colour of Reset Supply Type of contact Cable Reference Weight
ofcable enclosure voltage anchor
point

kg
110937

y 30 m Red RAL3000 By booted 1 1 NC + NO Both sides XY2CH13250 (3) 0.865


2 body and
stainless steel
pushbutton
By mushroom 1 1
slow break (right or left)
XY2CH13350 (3) 0.900
cover head pushbutton
XY2CH13250 By key operated 1 1 XY2CH13450 (3) 0.910
pushbutton
(key n421) (2)
By flush 2 NC + NC Both sides XY2CH13170 (3) 0.865

3 pushbutton
By booted 2
slowbreak (right or left)
XY2CH13270 (3) 0.865
pushbutton
By mushroom 2 XY2CH13370 (3) 0.865
head pushbutton
By key operated 2 XY2CH13470 (3) 0.910
pushbutton
(key n421) (2)
4 By flush
pushbutton
2 1 2 NC + 1 NO Both sides XY2CH13190 (3)
slowbreak (right or left)
0.865

By booted 2 1 XY2CH13290 (3) 0.865


pushbutton
By mushroom 2 1 XY2CH13390 (3) 0.865
head pushbutton
With pilot light (direct supply)
5 y 30 m Red RAL3000 By booted
body and pushbutton
24 V 1 1 NC + NO Both sides XY2CH13253
slow break (right or left)
0.900

stainless steel 2 NC + NC XY2CH13273 0.900


cover slow break
2 1 2 NC + 1 NO XY2CH13293 (3) 0.950
slowbreak
Latching Emergency stops
6 (turnbuckle, cable and end spring to be ordered separately) (1)
Without pilot light
110940

y 70 m Red RAL 3000 By booted 1 1 NC + NO Right side XY2CE1A250 (5) 1.450


(4) body and pushbutton slow break Left side XY2CE2A250 (5) 1.450
stainless steel
cover
2 NC + NC Right side XY2CE1A270 (5) 1.450

7
slow break Left side XY2CE2A270 (5) 1.450

By key switch 1 1 NC + NO Right side XY2CE1A450 (5) 1.465


XY2CE2A250 (key n421) slow break Left side XY2CE2A450 (5) 1.465

2 NC + NC Right side XY2CE1A470 (5) 1.470


slow break Left side XY2CE2A470 (5) 1.470

8 With pilot light (direct supply)


y 70 m Red RAL 3000 By booted 24 to 130 V 2 2 NC + NO Right side XY2CE1A296 1.470
(4) body and pushbutton slow break Left side XY2CE2A296 1.470
stainless steel
cover
230 to 240 V 2 2 NC + NO Right side XY2CE1A297 1.470
slow break
Left side XY2CE2A297 1.470

9 Other versions See order forms on pages 7 and 8.


XY2CE with reset by 40 mm mushroom head pushbutton or with integral cable tensioner and
support.
Please consult our Customer Care Centre.
(1) See separate components, page 9.
(2) 30 spring return key operated mushroom head pushbutton.
(3) For ISO M20 threaded cable entry version, add H29 to the end of the reference selected. .

10 Example: XY2CH13250 becomes XY2CH13250H29.


(4) Available with window for viewing cable tension indicator, for adjustment whilst the cover is closed (see versions XY2CEpDppp
and XY2CEpEppp on the order form, page 8).
(5) ATEX version available (products for explosive atmospheres): To order, add EX to the end of the reference.
Example: XY2CE1A250 becomes XY2CE1A250EX.

6
Order form . Safety detection solutions
(specimen suitable. Emergency stop rope pull switches
for photocopying) Preventa XY2C

Complete units, pre-assembled

Customer Schneider Electric Industries SA 1


110937

Company Order N Delivery date Sales office - Subsidiary Co. Order N

XY2CH13250

2
How to use this form:
- indicate the number of Emergency stop switches required,
- complete the basic reference.

Reference

Number of identical
Emergency stops
XY2CH 3

Model
Emergency stop (latching) 1

Degree of protection 4
IP 65 (standard bellows) with integral tensioner 3
IP 65 (silicone bellows) with integral tensioner 4

Type of reset
Emergency stop (1) Flush 1

5
Reset by spring return Booted 2
pushbutton
Mushroom head, 30 3
Key operated mushroom head, 30 4
(keyn 421)
Key operated mushroom head, 30 5
(keyn 455)
Key operated mushroom head, 30 (2) 9

6
Contact blocks for Emergency stop function (3)
Slow break 1 NC + 1 NO (NO staggered) 5
2 NC 7
2 NC + 1 NO 9

Pilot light
Without pilot light 0
7
With 24 V direct supply pilot light 3
With 48 V direct supply pilot light 4
With 130 V direct supply pilot light 5
With 230 V direct supply pilot light 7

Tapped cable entry


1/2" NPT (4) H7
8
ISO M20 H29

Increased protection
Treatment against corrosion (5) TK

(1) Opening of a circuit + mechanical latching in the open position.


(2) Other key numbers: 458A, 520E, 1242A, 1243E, 1344A, 1422A, 1431E, 2123E and 2132E.
9
(3) Emergency stop rope pull switches can only be fitted with slow break contact blocks.
(4) Only for versions without pilot light. For versions with pilot light, order an H4 version.
(5) Protective treatment TK is only possible for switches with silicone bellows (XY2CH14pppTK, XY2CH14pppH29TK, etc).

10

7
Order form . Safety detection solutions
(specimen suitable. Emergency stop rope pull switches
for photocopying) Preventa XY2C

Complete units, pre-assembled

1
110940

Customer Schneider Electric Industries SA


Company Order N Delivery date Sales office - Subsidiary Co. Order N

2 XY2CE2A250
How to use this form:
- indicate the number of Emergency stop switches required,
- complete the basic reference.

Reference

3 Number of identical XY2CE


Emergency stops

Models
Emergency stop Anchor point on right side 1

4 (latching) Anchor point on left side 2

Degree of protection and cable tension indicator window


IP 65 (standard bellows) without cable tension indicator window A
IP 65 (silicone bellows) without cable tension indicator window C
IP 65 (standard bellows) with cable tension indicator window D

5
IP 65 (silicone bellows) with cable tension indicator window E

Type of reset
Emergency stop (1) Flush 1
Reset by spring Booted 2
return
Mushroom head, 30 3
pushbutton
Key operated mushroom head, 30 4

6
(keyn 421)
Key operated mushroom head, 30 5
(keyn 455)
Key operated mushroom head, 30 9
(keyn 458A or n 520E)

Contact blocks for Emergency stop function (2)

7 Slow break 1 NC + 1 NO
2 NC
5
7
2 NC + 2 NO (compulsory with pilot light) (3) 9

Pilot light
Without pilot light 0
Protected LED, 24 - 130 V supply voltage pilot light (provide for 2 contact blocks) 6

8 Protected LED, 230 V supply voltage pilot light (provide for 2 contact blocks) 7

Version for North American countries


Tapped cable entry 1/2 NPT H7

Increased protection
Treatment against corrosion (4) TK
9 (1) Opening of a circuit + mechanical latching in the open position
(2) Emergency stop rope pull switches can only be fitted with slow break contact blocks.
(3) The use of a pilot light means selecting a switch fitted with 2 NC + 2 NO contacts: XY2CEppp9p.
(4) Protective treatment TK is only possible for switches with silicone bellows (XY2CEpCpppTK, XY2CEpEpppH7TK).

10

8
References Safety detection solutions
Emergency stop rope pull switches
Preventa XY2C
62

Separate components
803025

Description For use with Diameter Length Reference Weight

XY2CZ203
Galvanised cables XY2CH
mm
3.2
m
10.5 XY2CZ301
kg
0.280
1
with red sheath
15.5 XY2CZ3015 0.410
25.5 XY2CZ302 0.690
803017

30.5 XY2CZ303 0.830

XY2CZ402
XY2CE 5 15.5
25.5
XY2CZ1015
XY2CZ102
0.850
1.400
2
50.5 XY2CZ105 2.750
810060

70.5 XY2CZ107 3.870


XY2CZ503
Description Type For use with Sold in Unit reference Weight

3
lots of kg
803019

Tensioner XY2CE 1 XY2CZ203 0.090


810061

Turnbuckles M6 x 60 + locknut All models (1) 1 XY2CZ402 0.060


XY2CZ524 XY2CZ601
M8 x 70 + locknut All models (1) 1 XY2CZ404 0.100

Cable grips Single Cable 3 to 5 mm 10 XY2CZ503 0.007


803020

Double
Clamp
Cable 3 to 5 mm
Cable 3.2 mm
10
10
XY2CZ513
XY2CZ523
0.016
0.050
4
Cable 5 mm 10 XY2CZ524 0.080
803018

Cable supports Fixed All models 10 XY2CZ601 0.030


Swivelling All models 1 XY2CZ602 0.130
Pulley support All models 1 XY2CZ705 0.060 5
XY2CZ602 XY2CZ705
Pulley Cable 5 mm max. XY2CH and XY2CE 1 XY2CZ708 0.002

Cable end protectors Cable 3.2 mm 10 XY2CZ701 0.002


803016

Cable 5 mm 10 XY2CZ704 0.010


810062

XY2CZ708 XY2CZ701
End springs XY2CH 1 XY2CZ703 0.035 6
XY2CE 1 XY2CZ702 0.080

Mounting accessories and kits


803021

Contents For use with Cable Length Reference Weight


diameter ofcable

XY2CZ702 Bracket XY2CE


mm

m
XY2CZ804
kg
0.474 7
DF601301

1 spring tensioner XY2CH XY2CZ918 0.010


+ + 1 notched washer + 1 circlip

1 galvanised cable XY2CH 3.2 10 XY2CZ9310 0.415


+
8
+ 1 cable grip XY2CZ523
+ 1 end spring XY2CZ703
15 XY2CZ9315 0.535
XY2CZ918

30 XY2CZ9330 0.915
DF601441

1 galvanised cable XY2CE 5 25 XY2CZ9525 1.905


+ 4 cable grips XY2CZ524
+ 1 turnbuckle XY2CZ404, 9
+ 1 cable support XY2CZ601 50 XY2CZ9550 3.280
+ 3 cable end protectors
XY2CZ704
+ 1 end spring XY2CZ702. 70 XY2CZ9570 4.000

XY2CZ804
(1) Emergency stop rope pull switches XY2CH13ppp and XY2CH14ppp incorporate a cable tensioner as standard.
Therefore, there is no need to order a turnbuckle. 10

General: Characteristics: Dimensions:


pages 2 to 4 page 5 page 11

9
References (continued) Safety detection solutions
Emergency stop rope pull switches
Preventa XY2C

Replacement parts
Description For use with Type Reference Weight
1 Reset pushbutton (blue), XY2CH Flush with R marked on push ZB5AA639
kg
0.018
spring return
Booted ZB5AP6 0.019

Mushroom head, 30 ZB5AC64 0.027

XY2CE Flush with R marked on push ZB5AA639 0.018

2 Booted ZB5AP6S 0.021

Mushroom head, 30 ZB5AC64 0.027

Key switch XY2CH and XY2CE With key n 421 ZB5AG612R26 0.064

With key n 455 ZB5AG6R26 0.064

Keys for reset button All types of Emergency stop N 421 Q99900911 0.006
3 N 455 Q99900901 0.006

Pilot light head assembly XY2CE Red XY2CZ800 0.015


601438

Orange XY2CZ801 0.015

Set of 5 cover gaskets XY2CE XY2CZ805 0.122

4 XY2CZ805
Fixing nut, plastic, grey XY2CH and XY2CE ZB5AZ901 0.002

Fixing nut tightening key, XY2CH and XY2CE ZB5AZ905 0.016


plastic, grey For fixing nut ZB5AZ901

Description For use with Voltage Sold in Unit reference Weight


lotsof kg
Pilot lights XY2CH 24 V 1 XY2CZ0024 (1) 0.035

5
803023

With bulb DL1AAppp Colour: orange


included 130 V 1 XY2CZ0130 (1) 0.035

230 V 1 XY2CZ0230 (1) 0.035

Supply on LED XY2CE 24 V 1 ZALVB4 0.015


Colour: red
130 V 1 ZALVG4 0.015

6 XY2CZpppp
XY2CE
230 to 240 V

24 V
1

1
ZALVM4

ZALVB5
0.015

0.015
Colour: orange
130 V 1 ZALVG5 0.015

230 to 240 V 1 ZALVM5 0.015

Incandescent bulbs, XY2CH 24 V - 6 W 10 DL1AA024 0.004

7 screw base fitting


130 V - 6 W 10 DL1AA127 0.004

230 V - 6 W 10 DL1AA220 0.004

Set of 5 collars For mounting DL1AA127 5 XY2CZ908 0.018


and DL1AA220 bulbs
in pilot lights XY2CZppp

8 (1) Only for use as replacement parts for switches pre-fitted with pilot lights. CCC and UL-CSA approvals no longer apply if an
XY2CZppp pilot light is mounted on Emergency stops XY2CH.

10

General: Characteristics: Dimensions:


pages 2 to 4 page 5 page 11

10
Dimensions Safety detection solutions
Emergency stop rope pull switches
Preventa XY2C

Latching Emergency stops


XY2CH
Without pilot light With pilot light 1
(2) (2)
(2) 6,5 (2) 6,5

(3)
48
68

56
68

68

48
56
(2) 197 40 55 (1) (2) 197 40 55 (1)
2
201 (1) 201 (1)

(1) Maximum extension.


(2) Tapped entries for n 13 (Pg 13.5) cable gland. For ISO M20 the reference becomes XY2CHpppppH29.
(3) 121 mm: 24 V and 48 V versions. 131 mm: 130 V and 230 V versions.
XY2CE
3
XY2CE1Appp (anchor point on right side) XY2CEpAppp + XY2CZ804 bracket

229 (2) 243


105 (2)
195 52
12 120 20

4
6
44


142

(1) (1)
63

(1) 28
5
31 82 25
57,5

Accessories
XY2CZ705 XY2CZ708 6
M8 9
53
55

7
(1) 3 plain holes for n 13 (Pg 13.5) or ISO M20 cable gland.
(2) Maximum extension.
: 4 elongated holes 6 mm.

10

General: Characteristics:
pages 2 to 4 page 5

11
Characteristics Detection solutions
Rope pull switches XY2CB

Environment
Conformity to standards Products EN/IEC 60947-5-1, CSA C 22-2 n 14 (with suffix H2)
1 Product certifications CSA A 600-Q 600 (with suffix H2)
Protective treatment Standard version TC
Special version TH
Ambient air temperature For operation - 25+ 70 C
For storage - 40+ 70 C
Electric shock protection Class I conforming to IEC61140
2 Degree of protection Enclosure: IP 22, contact housing: IP 65, conforming to IEC 60529
Mechanical life 10,000 operating cycles
Length of protected zone y 100 metres and y 2 x 100 metres
Distance between cable supports 5m
Cable entries See dimensions, page 15.

3 Contact block characteristics


Rated operational characteristics AC-15: A 600 or Ue = 600 V, le = 1.2 A
DC-13: Q 600 or Ue = 600 V, le = 0.1 A, conforming to EN/IEC 60947-5-1 Appendix A
Nominal thermal current 10 A
Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to EN/IEC 60947-1,
Ui = 600 V conforming to CSA C22-2 n 14
Rated impulse withstand voltage Uimp = 6 kV conforming to EN/IEC60947-1

4 Positive operation
Contact operation
NC contact with positive opening operation conforming to EN/IEC60947-5-1 Section3
NC + NC or NC + NO slow break
Resistance across terminals y 25 m conforming to NF C 93-050 method A or EN/IEC 60255-7 category 3
Terminal referencing Conforming to CENELEC EN 50013
Short-circuit protection 10 A cartridge fuse type gG (gl) conforming to IEC 60269

Rated operational power Conforming to EN/IEC 60947-5-1 Appendix C

5 (Electrical durability) Utilisation categories AC-15 and DC-13

Operating rate: 3600 operating cycles/hour AC supply a 5060 Hz


Load factor: 0,5 Power broken in VA (1)
o Inductive circuit
Voltage V 24 48 127 220
o VA 250 250 500 500

6 DC supply c
Power broken in W (1)
o Inductive circuit
Voltage V 24 48 120
o W 50 100 100

7 Contact connection Screw clamp terminals


Clamping capacity: min. 1 x 0.5 mm2, max. 2 x 1.5 mm2
Minimum tightening torque: 0.8 N.m
Maximum tightening torque: 1.2 N.m

(1) For 1 million operating cycles.

10

References: Dimensions:
page 13 page 15

12
References Detection solutions
Rope pull switches XY2CB

Rope pull switches


(End spring, turnbuckle and cable to be ordered separately) (1)
Without pilot light 1
Length Colour of Reset Type of contact Cable Reference Weight
ofcable enclosure anchor
point

kg
y 100 m Blue From inside enclosure 1 1 NC + NO Left side XY2CB10 (2) 18.750
123227

slow break
2
Right side XY2CB20 (2) 18.750

2 NC + NC Left side XY2CB104 18.750


slow break

Right side XY2CB204 18.750


3
y 2 x 100 m Blue From inside enclosure 1 1 NC + NO Both sides XY2CB30 (2) 29.250
XY2CB30 slow break (right or left)

2 NC + NC Both sides XY2CB304 29.250


slow break (right or left)

With pilot light


4
Length Colour of Reset Supply voltage Type of contact Cable Reference Weight
ofcable enclosure anchor
point

kg
b Direct supply
5
123229

y 100 m Blue From inside 24 V 1 1 NC + NO Left side XY2CB11 19.550


enclosure slow break

Right side XY2CB21 19.550

48 V 1 1 NC + NO Left side XY2CB12 19.550


slow break
6
Right side XY2CB22 19.550

y 2 x 100 m Blue From inside 24 V 1 1 NC + NO Both sides XY2CB31 25.600


enclosure slow break (right or left)
XY2CB21
48 V 1 1 NC + NO
slow break
Both sides XY2CB32
(right or left)
30.050
7
b Supply via integral transformer (3)
y 100 m Blue From inside 127 V/6 V 1 1 NC + NO Left side XY2CB13 15.600
123228

enclosure slow break

8
Right side XY2CB23 15.600

220 V/6 V 1 1 NC + NO Left side XY2CB14 15.600


slow break

Right side XY2CB24 15.600

y 2 x 100 m Blue From inside


enclosure
127 V/6 V 1 1 NC + NO
slow break
Both sides XY2CB33
(right or left)
25.600 9
XY2CB13
220 V/6 V 1 1 NC + NO Both sides XY2CB34 25.600
slow break (right or left)

(1) See separate components, page 4.


(2) For 1/2 NPT threaded cable entry version, add the suffix H2 to the reference selected.
Example: XY2CB10 becomes XY2CB10H2.
(3) Bulb DL1CB006 included.
10

13
References (continued) Detection solutions
Rope pull switches XY2CB

Separate components and replacement parts


Description Diameter Length Reference Weight
1 Galvanised cables
mm
3.2
m
10.5 XY2CZ301
kg
0.280
with red sheath
15.5 XY2CZ3015 0.410

25.5 XY2CZ302 0.690

2 50.5 XY2CZ305 1.360

100.5 XY2CZ310 2.700


803018

Description Type Sold in Unit reference Weight


lots of kg
Turnbuckles M6 x 60 + 1 XY2CZ402 0.060
810061

3 locknut
M8 x 70 + 1 XY2CZ404 0.100
XY2CZ601 XY2CZ602
locknut
Cable grips Simple 10 XY2CZ503 0.007
for cables 3 to 5 mm
Double 10 XY2CZ513 0.016

4
803021

Cable grips Clamp 10 XY2CZ523 0.050


for cables 3.2 mm
810062

Cable supports Fixed 10 XY2CZ601 0.030


XY2CZ707 XY2CZ701
Swivelling 1 XY2CZ602 0.130

5
Pulley support 1 XY2CZ705 0.060

Cable end protectors 10 XY2CZ701 0.002


111270

for cables 3.2 mm


End spring 1 XY2CZ707 0.314

Description Voltage Sold in Unit reference Weight

6 9001KP35R9 Pilot lights 24 V


lots of
1 9001KP35R9
kg
0.134
With bulb DL1AAppp included
120 V 1 9001KP1R9 0.210

230 V 1 9001KP7R9 0.210

7 Incandescent bulbs,
BA 9s base fitting
24 V - 2.6 W 10 DL1CE024 0.002

6 V - 1.2 W 10 DL1CB006 (1) 0.002

ISO M20 adaptor 5 DE9RP13520 0.050

(1) For use with XY2CB, 120 V and 230 V.


8

10

Characteristics: Dimensions:
page 12 page 15

14
Dimensions Detection solutions
Rope pull switches XY2CB

Dimensions
XY2CB
Without pilot light With pilot light 1
(1) 56 208 (1) 56 208

265

265
3
458

523
4x8 4x8

4
112

198
(3) = 210 = (3)
155 (2) 240

155 (2) 80 5
= 210 =
240

(1) 2 access points for operating cable.


(2) + 125 for opening cover.
(3) 1 tapped entry for n 13 (Pg 13.5) cable gland. For ISO M20 use adaptor DE9RP13520.
6

10

15
Index Product reference index

9001KP1R9 14 XY2CH13290 6 XY2CZ9550 9


9001KP7R9 14 XY2CH13293 6 XY2CZ9570 9
9001KP35R9 14 XY2CH13350 6
XY2CH13370 6 Z
D ZALVB4 10
XY2CH13390 6
DE9RP13520 14 ZALVB5 10
XY2CH13450 6
DL1AA024 10 ZALVG4 10
XY2CZ0024 10
DL1AA127 10 ZALVG5 10
XY2CZ102 9
DL1AA220 10 ZALVM4 10
XY2CZ105 9
DL1CB006 14 ZALVM5 10
XY2CZ107 9
DL1CE024 14 ZB5AA639 10
XY2CZ0130 10
ZB5AC64 10
XY2CZ203 9
Q ZB5AG6R26 10
XY2CZ0230 10
Q99900901 10
ZB5AG612R26 10
XY2CZ301 9.
Q99900911 10
14 ZB5AP6 10
XY2CZ302 9. ZB5AP6S 10
X 14
ZB5AZ901 10
XY2CB10 13 XY2CZ303 9
ZB5AZ905 10
XY2CB11 13 XY2CZ305 14
XY2CB12 13 XY2CZ310 14
XY2CB13 13 XY2CZ402 9.
XY2CB14 13 14

XY2CB20 13 XY2CZ404 9.
14
XY2CB21 13
XY2CZ503 9.
XY2CB22 13 14
XY2CB23 13 XY2CZ513 9.
XY2CB24 13 14

XY2CB30 13 XY2CZ523 9.
14
XY2CB31 13
XY2CZ524 9
XY2CB32 13
XY2CZ601 9.
XY2CB33 13 14
XY2CB34 13 XY2CZ602 9.
XY2CB104 13 14

XY2CB204 13 XY2CZ701 9.
14
XY2CB304 13
XY2CZ703 9
XY2CE1A250 6
XY2CZ704 9
XY2CE1A270 6
XY2CZ705 9.
XY2CE1A296 6 14
XY2CE1A297 6 XY2CZ707 14
XY2CE1A450 6 XY2CZ708 9
XY2CE1A470 6 XY2CZ800 10
XY2CE2A250 6 XY2CZ801 10
XY2CE2A270 6 XY2CZ804 9
XY2CE2A296 6 XY2CZ805 10
XY2CE2A297 6 XY2CZ908 10
XY2CE2A450 6 XY2CZ918 9
XY2CE2A470 6 XY2CZ1015 9
XY2CH13170 6 XY2CZ3015 9
XY2CH13190 6 14
XY2CH13250 6 XY2CZ9310 9
XY2CH13253 6 XY2CZ9315 9
XY2CH13270 6 XY2CZ9330 9
XY2CH13273 6 XY2CZ9525 9

16
Schneider Electric Industries SAS www.tesensors.com
Head Office The information provided in this documentation contains general descriptions and/or technical
35, rue Joseph Monier characteristics of the performance of the products contained herein. This documentation is not
F-92500 Rueil-Malmaison intended as a substitute for and is not to be used for determining suitability or reliability of these
France products for specific user applications. It is the duty of any such user or integrator to perform the
appropriate and complete risk analysis, evaluation and testing of the products with respect to the
relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or
subsidiaries shall be responsible or liable for misuse of the information contained herein.

Design: Schneider Electric


Photos: Schneider Electric

You might also like