Professional Documents
Culture Documents
: 10A112301EL-02 Page 1 of 46
Test Report
(Declaration of Conformity)
for
Electromagnetic Compliance
of
Prepared for
Prepared by
Table of Contents
1 General Information 5
1.1 Description of Equipment Under Test 5
1.2 Specifications 6
1.3 Details of Tested Supporting System 7
1.4 Test Facility 8
1.5 Measurement Uncertainty 9
1.6 Configuration of EUT Setup 10
8 Photographs of Test 44
8.1 Main Terminal & Control Terminal Disturbance Voltage Measurement 44
8.2 Radiated Disturbance (9 kHz to 30 MHz) Measurement 45
8.3 Radiated Disturbance (30 MHz to 300 MHz) Measurement 46
Statement of Compliance
Applicant: MEAN WELL ENTERPRISES CO., LTD.
Manufacturer: 1. Mean Well Enterprises Co., Ltd.
2. Mean Well (GUANGZHOU) Electronics Co., Ltd.
3. SuZhou Mean Well Technology Co., Ltd.
Product: Switching Power Supply
Model No.: HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Tested Power Supply: 230Vac, 50Hz; 110Vac, 60Hz
Date of Final Test: Aug. 14, 2015
Revision of Report: Rev. 02
Measurement Procedures and Standards Used
Emission: Immunity:
EN 55015: 2013 EN 61547: 2009
EN 61000-3-2: 2014 EN 61000-4-2: 2009
EN 61000-3-3: 2013 EN 61000-4-3: 2006+A1: 2008+A2: 2010
EN 61000-4-4: 2012
EN 61000-4-5: 2006
EN 61000-4-6: 2014
EN 61000-4-8: 2010
EN 61000-4-11: 2004
The measurement results in this test report were performed at Interocean EMC Technology
Corp. the responsibility of measurement result is only subjected to the tested sample.
This report shows the EUT is technically compliance with the above official standards.
This report shall not be partial reproduced without written approval by Interocean EMC
Technology Corporation.
1 General Information
1.2 Specifications
Output
Model No.
Voltage (Vdc) Current (A)
HLx-80H-12z; HLG-80H-12BL 12 5
HLx-80H-15z; HLG-80H-15BL 15 5
HLx-80H-20z; HLG-80H-20BL 20 4
1. HLx-80H-yz (x=G stand for metal enclosure with potting compound, N stand
for plastic enclosure without potting compound, P stand for open frame type;
y=12, 15, 20, 24, 30, 36, 42, 48, 54 for output voltage;
z=A or B or D or Blank)
2. HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54)
3. Models HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54) are identical to
HLx-80H-yz except for the wires termination shall be inside a junction box.
Connected to mains
Power Cord
B2
B1
A1 x 2 (+)
EUT A2 x 2 (-) Dummy Load
Power Cable
Connecting Cables:
Shielded Supported
No. Cable Length Shielded Note
Backshell by lab.
A1 Power Cable (+) 1m
A2 Power Cable (-) 1m
B1 Power Cord 0.3 m
B2 Power Cord 1.5 m R
2.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
RF Cable
0.8 m
0.4 m
LISN
LISN
Power Cord
0.4 m to vertical ground
Bonded to horizontal
Bonded to horizontal reference plane
ground plane
ground plane
3.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
Control
Unit
ISN 0.8 m
Bonded to Vertical
ground plane
0.4 m
Telecommunication LISN
Bonded to LISN
horizontal Cable
ground plane
Power Cord 0.4 m to vertical ground
Bonded to horizontal
reference plane
ground plane
4.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
EMI Test 50 cm
Receiver
RF Cable
5.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
Biconical Antenna Schwarzbeck VHA 9103 & BBA 9106 VHA 9103-2418 2016/07/05
10 m
RF Cable
4m
1m 80 cm
Pre-Amplifier Turntable
6.1 EN 61547
Criterion Description
A During the test no change of the luminous intensity shall be observed and the
regulating control, if any, shall operate during the test as intended.
B During the test the luminous intensity may change to any value. After the test the
luminous intensity shall be restored to its initial value within 1 min.
Regulating controls need not function during the test, but after the test the mode of
the control shall be the same as before the test provided that during the test no mode
changing commands were given.
C During and after the test any change of the luminous intensity is allowed and the
lamp(s) may be extinguished. After the test, within 30 min, all functions shall return
to normal if necessary by temporary interruption of the mains supply and / or
operation the regulating control.
Additional requirement for lighting equipment incorporation a starting device:
After the test the lighting equipment is switched off. After half an hour it is switched
on again. The lighting equipment shall start and operate as intended.
7.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
EUT
EMC Test System
Ground Plane
10cm
Insulation support
Grounding cable
PASS.
8 Photographs of Test
Front View
Rear View
Front View
Rear View
Test Report
(Declaration of Conformity)
for
Electromagnetic Compliance
of
Prepared for
Prepared by
Interocean EMC Technology Corp.
No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang,
Taipei County 244, Taiwan, R.O.C.
TEL.: +886 2 2600 6861
FAX.: +886 2 2600 6859
Remark:
The test report consists of 5 pages in total. It shall not be reproduced except in full,
without the written approval of IETC. This document may be altered or revised by
IETC only, and shall be noted in the revision section of the document.
The test result in this report is only subjected to the test sample.
Table of Contents
1 General Information 4
1.1 Description of Equipment Under Test 4
1.2 Specifications 5
Statement of Compliance
Applicant: MEAN WELL ENTERPRISES CO., LTD.
Manufacturer: 1. Mean Well Enterprises Co., Ltd.
2. MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD.
3. SuZhou Mean Well Technology Co., Ltd.
Product: Switching Power Supply
Model No.: HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Tested Power Supply: 230Vac, 50Hz; 110Vac, 60Hz
Date of Final Test: Dec. 29, 2010
Revision of Report: Rev. 00
Measurement Procedures and Standards Used
Emission: Immunity:
EN 55015: 2006+A1: 2007+A2: 2009 EN 61547: 2009
EN 61000-3-2: 2006+A1: 2009+A2: 2009 EN 61000-4-2: 2009
EN 61000-3-3: 2008 EN 61000-4-3: 2006+A1: 2008+A2: 2010
EN 61000-4-4: 2004+A1: 2010
EN 61000-4-5: 2006
EN 61000-4-6: 2009
EN 61000-4-8: 2010
EN 61000-4-11: 2004
The measurement results in this test report were performed at Interocean EMC Technology
Corp. the responsibility of measurement result is only subjected to the tested sample.
This report shows the EUT is technically compliance with the above official standards.
This report shall not be partial reproduced without written approval by Interocean EMC
Technology Corporation.
1 General Information
(For 10A112301EL-01)
1.) 10A112301EL-01 is a multiple report of 10A112301EL, the differences
are updated the standard and changed the address of Applicant and
Manufacturer (because of municipality change by government).
These modifications are not influence to the previous test result,
therefore, there is no further test necessary in this report.
1.2 Specifications
HLx-80H-12z; HLG-80H-12BL 12 5
HLx-80H-15z; HLG-80H-15BL 15 5
HLx-80H-20z; HLG-80H-20BL 20 4
1. HLx-80H-yz (x=G stand for metal enclosure with potting compound, N stand
for plastic enclosure without potting compound, P stand for open frame type;
y=12, 15, 20, 24, 30, 36, 42, 48, 54 for output voltage;
z=A or B or D or Blank)
2. HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54)
3. Models HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54) are identical to
HLx-80H-yz except for the wires termination shall be inside a junction box.
Test Report
(Declaration of Conformity)
for
Electromagnetic Compliance
of
Prepared for
Prepared by
Interocean EMC Technology Corp.
No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang,
Taipei County 244, Taiwan, R.O.C.
TEL.: +886 2 2600 6861
FAX.: +886 2 2600 6859
Remark:
The test report consists of 385 pages in total. It shall not be reproduced except in
full, without the written approval of IETC. This document may be altered or revised
by IETC only, and shall be noted in the revision section of the document.
The test results in the report only to the tested sample.
Table of Contents
1 General Information 7
1.1 Description of Equipment Under Test 7
1.2 Specifications 8
1.3 Details of Tested Supporting System 9
1.4 Summary of Test Results 10
1.5 Test Facility 11
1.6 Measurement Uncertainty 12
1.7 Measured Mode 13
1.8 Configuration of EUT Setup 14
1.9 Test Step of EUT (Main Terminal Disturbance Voltage) 15
1.10 Test Step of EUT (Radiated Disturbance (9 kHz to 30 MHz)) 15
1.11 Test Step of EUT (Radiated Disturbance (30 MHz to 300 MHz)) 15
Statement of Compliance
Applicant: MEAN WELL ENTERPRISES CO., LTD.
Manufacturer: 1. Mean Well Enterprises Co., Ltd.
2. MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD.
3. SuZhou Mean Well Technology Co., Ltd.
Product: Switching Power Supply
Model No.: HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Tested Power Supply: 230Vac, 50Hz; 110Vac, 60Hz
Date of Final Test: Dec. 29, 2010
Revision of Report: Rev. 03
Measurement Procedures and Standards Used
Emission: Immunity:
EN 55015: 2006+A1: 2007+A2: 2009 EN 61547: 2009
EN 61000-3-2: 2006 EN 61000-4-2: 2009
EN 61000-3-3: 2008 EN 61000-4-3: 2006+A1: 2008
EN 61000-4-4: 2004
EN 61000-4-5: 2006
EN 61000-4-6: 2009
EN 61000-4-8: 1993+A1: 2001
EN 61000-4-11: 2004
The measurement results in this test report were performed at Interocean EMC Technology
Corp. the responsibility of measurement result is only subject to the tested sample.
This report shows the EUT is technically compliance with the above official standards.
This report shall not be partial reproduced without written approval by Interocean EMC
Technology Corporation.
1 General Information
1.2 Specifications
HLx-80H-12z; HLG-80H-12BL 12 5
HLx-80H-15z; HLG-80H-15BL 15 5
HLx-80H-20z; HLG-80H-20BL 20 4
1. HLx-80H-yz (x=G stand for metal enclosure with potting compound, N stand
for plastic enclosure without potting compound, P stand for open frame type;
y=12, 15, 20, 24, 30, 36, 42, 48, 54 for output voltage;
z=A or B or D or Blank)
2. HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54)
3. Models HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54) are identical to
HLx-80H-yz except for the wires termination shall be inside a junction box.
Radio-frequency common
12 AC power port 5.6 EN 61000-4-6 PASS
mode
Power frequency
13 Enclosure port 5.4 EN 61000-4-8 PASS
magnetic fields
Voltage dips and short
14 AC power port 5.8 EN 61000-4-11 PASS
interruptions
1.7.2 For conducted and radiated tests, selected the worst-case modes 1~38 after preliminary
test for final test.
1.7.3 For EN 61000-3-3 and immunity tests, selected the mode 8 for final test.
1.7.4 For EN 61000-3-2 test, the test modes are:
100% LED LOAD (HLG-80H-48A) (230V)
60% LED LOAD (HLG-80H-48A) (230V)
Connected to mains
Power Cord
A2 1.5m
A1 + A2=max. 1.8m
B1 + B2=1m A1 0.3m
0.7m 0.3m
LED Load B2 B1
EUT
Power Cable
1.11 Test Step of EUT (Radiated Disturbance (30 MHz to 300 MHz))
1.11.1 Setup the EUT and peripheral as above.
1.11.2 Turn on the power of the equipment.
1.11.3 Executed the test.
2.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
RF Cable
0.8 m
0.4 m
LISN
LISN
Power Cord
0.4 m to vertical ground
Bonded to horizontal
Bonded to horizontal reference plane
ground plane
ground plane
3.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
EMI Test 50 cm
Receiver
RF Cable
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
4.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
RF Cable
4m
EUT
5.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
Class B Equipment
For Class B equipment, the harmonics of the input current shall not exceed the values given in
Class A equipment multiplied by a factor of 1.5.
Class C Equipment
Harmonic order Maximum permissible harmonic current
expressed as a percentage of the input
current at the fundamental frequency
(n) %
2 2
3 30.*
5 10
7 7
9 5
11 n 39 3
(odd harmonics only)
*is the circuit power factor
Class D Equipment
Harmonic order Maximum permissible Maximum permissible
harmonic current harmonic current
Per watt
(n) (mA/W) (A)
3 3.4 2.30
5 1.9 1.14
7 1.0 0.77
9 0.5 0.40
11 0.35 0.33
13 n 39 3.85/n See Class A equipment
(odd harmonics only)
6.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
7.1 EN 61547
Criterion Description
A During the test no change of the luminous intensity shall be observed and the
regulating control, if any, shall operate during the test as intended.
B During the test the luminous intensity may change to any value. After the test the
luminous intensity shall be restored to its initial value within 1 min.
Regulating controls need not function during the test, but after the test the mode of
the control shall be the same as before the test provided that during the test no mode
changing commands were given.
C During and after the test any change of the luminous intensity is allowed and the
lamp(s) may be extinguished. After the test, within 30 min, all functions shall return
to normal if necessary by temporary interruption of the mains supply and / or
operation the regulating control.
Additional requirement for lighting equipment incorporation a starting device:
After the test the lighting equipment is switched off. After half an hour it is switched
on again. The lighting equipment shall start and operate as intended.
8.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
10 cm
ESD Generator
Vertical
Coupling Insulation
Plane EUT
Ground
Connection (HCP)
470k 470k
80 cm Resister Resister
PASS.
9.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
Chamber
3m
RF Cable
EUT
1m
80 cm
RF Power Amplifier
PASS.
10.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
EUT
Insulation support
Grounding cable
Bounding
Metal Ground Plane
PASS.
11.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
Surge
EUT Generator
Controller Computer
PASS.
12.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
50 terminator
6dB Attenuator
30 cm
C.D.N. EUT AE C.D.N.
Main Power
10 cm
Metal Ground Plane
PASS.
12.6.1 The performance criterion after tested EN 61000-4-6 (EN 61547):
Frequency range: 0.15 to 80 MHz, Field strength: 3 V, 80% AM (1kHz),
Input AC power port.
Performance criterion: A B C
13.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
Induction coil
1/2 Dimension of EUT
EUT
Non-Conducted Table
PASS.
14.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date
EUT
Grounding cable
Bounding
Metal Ground Plane
Class Xb X X X X X
a
Classes as per EN 61000-2-4; see Annex B.
b
To be defined by product committee. For equipment connected directly or indirectly to the public
network, the levels must not be less severe than Class 2.
c
25/30 cycles means 25 cycles for 50 Hz test and 30 cycles for 60 Hz test.
Preferred test level and durations for short interruptions
Class a Test level and durations for short interruptions (ts) (50 Hz/60 Hz)
Class 1 Case-by-case according to the equipment requirements
Class 2 0 % during 250/300c cycles
Class 3 0 % during 250/300c cycles
Class Xb X
a
Classes as per EN 61000-2-4; see Annex B.
b
To be defined by product committee. For equipment connected directly or indirectly to the public
network, the levels must not be less severe than Class 2.
c
250/300 cycles means 250 cycles for 50 Hz test and 300 cycles for 60 Hz test.
PASS.
15 Photographs of Test
Front View
Rear View
Front View
Rear View
Front View
Rear View
16 Photographs of EUT
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
Spec.
17 Photographs of PCB