VOTANO 100

Accurate and mobile voltage transformer testing system

OMICRON 20 August 2014


Sophisticated voltage transformer testing

> Mobile and accurate voltage transformer testing


> Inductive and capacitive coupled
voltage transformers (VTs and CVTs)
> Testing in power system grids, production
facilities, and test/development labs
> Protection and metering applications
> Determination of all important
transformer parameters:
> Winding resistance
> Magnetic characteristics curves
> Short-circuit impedances
> Transformation ratio
> Phase angle

OMICRON Page 2
Your benefits

> Mobile: compact size and low weight


(< 15 kg / 33 lbs)
> Accurate: field calibration of VTs up to
the 0.1 accuracy class
> Fast: software-guided test procedure ensures
short testing time (< 20 min)
> Convenient: automatic result assessment as per
IEEE and IEC standards directly after the test
> Efficient: simulation and re-assessment
with changed VT parameters
> Safe: 4 kV maximum test voltage and
local isolation between high voltage and
measuring equipment

OMICRON Page 3
VOTANO 100

Generator Grounding
output terminal

Measurement Communication
input 1 interface to VBO1

Measurement PC connection
input 2

Compact Flash
card slot

OMICRON Page 4
Voltage booster VBO1
Winding resistance,
Ratio tests short-circuit impedance,
and excitation tests

Emergency
stop button

Grounding
terminal
Communication
interface to
VOTANO 100

VOTANO 100 VOTANO 100


interface for interface for
ratio test all other tests

OMICRON Page 5
Test procedure

Voltage transformer testing with VOTANO 100

Step 1: measurement of parameters Step 2: modeling

Software-guided measurement of different Determination of VT model elements and


VT parameters such as winding resistance, calculation of VT accuracy through
magnetization characteristics, etc. embedded mathematical functions

OMICRON Page 6
Test procedure

Voltage transformer testing with VOTANO 100

Step 3: IEEE/IEC assessment Step 4: reporting

Automated comparison of test results with All data can be saved in Excel and XML
the defined values in accordance with the format or can be printed as a test report.
selected IEEE or IEC standard

OMICRON Page 7
Test procedure

Maximum safety during testing


> Supplied voltage booster VBO1: located in
high-voltage environment
> User and VOTANO 100: located in safe area
outside the high-voltage environment
> VBO1 provides 4 kV maximum test voltage
for ratio measurement
> Grounding and plausibility check
> Acoustic warnings VOTANO 100 VBO1

> Emergency stop button or


optional dead man switch
High-voltage
environment
Safe area

OMICRON Page 8
Test procedure

Test sequence

1. ** 2. ** 3. Secondary *
Specification of
voltage
transformer data
Short-circuit
impedance
Winding
resistance
short-circuit
impedance
...
measurement measurement measurement

**
... 4.
Excitation
measurement
VT or
CVT?
VT 5.
VT ratio
measurement

CVT
* if more than two
secondary windings 4b.
are available 4a.
CVT
CVT ratio
** repeated for every inductive ratio
measurement
secondary winding. measurement

OMICRON Page 9
Test procedure

1. Short-circuit impedance measurement

VT CVT

Emergency switch Emergency switch


VOTANO 100 VOTANO 100
VOTANO 100 VOTANO 100

OMICRON Page 10
Test procedure

2. Winding resistance measurement

CVT / VT

Emergency switch
VOTANO 100
VOTANO 100

OMICRON Page 11
Test procedure

3. Secondary short-circuit impedance measurement

CVT / VT

Emergency switch
VOTANO 100
VOTANO 100

OMICRON Page 12
Test procedure

4. Excitation measurement

CVT / VT

Emergency switch
VOTANO 100
VOTANO 100

OMICRON Page 13
Test procedure

4a. CVT ratio measurement

CVT

Emergency switch
VOTANO 100
VOTANO 100

OMICRON Page 14
Test procedure

4b. CVT inductive ratio measurement

CVT

Emergency switch
VOTANO 100
VOTANO 100

OMICRON Page 15
Test procedure

5. VT ratio measurement

VT CVT

Emergency switch Emergency switch


VOTANO 100 VOTANO 100
VOTANO 100 VOTANO 100

OMICRON Page 16
Device operation

1 Operation via VOTANO 100 display


1
> Guided workflow with connection diagrams

> Display suitable for use in direct sunlight

2 Operation via PC software

> Control complete measuring procedure


with your PC

> Guided software workflow 2

> Remote control allows integration into


automated procedures of production line

> Automated pass/fail assessment of results

> Export reports in Excel and XML format

> Firmware upgrade

OMICRON Page 17
Result assessment

> Automated assessment as per IEEE and IEC standards


> Assessment is complete within seconds after measurement
> Complete class assessment considering;
> different burden values
> different primary voltage values
> other secondary windings under load and no-load conditions
> protection and metering class, simultaniously assessed per winding
> up to five windings in assessment matrix
> open delta winding
Unloaded Burden in % cos Phi VA 2% 5% 80% 100% 120%
Voltage ratio error in % at % of rated voltage, other winding unloaded
Ratio 100 0.8 15 0.088% 0.123% 0.177% 0.177% 0.176%
25 0.8 3.75 0.033% 0.362% 0.415% 0.417% 0.415%
Phase angle error in min. at % of rated voltage, other winding unloaded
Phase angle 100 0.8 15 4.825 min. 4.287 min. 3.180 min. 3.186 min. 3.245 min.
25 0.8 3.75 2.802 min. 2.263 min. 1.155 min. 1.161 min. 1.220 min.
Loaded Burden in % cos Phi VA 2% 5% 80% 100% 120%
Voltage ratio error in % at % of rated voltage, other winding loaded
Ratio 100 0.8 15 -0.57% -0.54% -0.482% -0.481% -0.483%
25 0.8 3.75 -0.33% -0.30% -0.246% -0.245% -0.246%
Phase angle error in min. at % of rated voltage, other winding loaded
Phase angle 100 0.8 15 2.320 min. 1.783 min. 0.678 min. 0.683 min. 0.737 min.
25 0.8 3.75 0.302 min. -0.235 min. -1.340 min. -1.335 min. -1.300 min.

OMICRON Page 18
Result assessment

> Error parallelogram as per IEEE standard

RCF
1.004
5 % UPR
1.003
25 % UPR
1.002 90 % UPR
100 % UPR
1.001
110 % UPR
1.000 ZZ
Z
0.999
Y
0.998 M
X
0.997
W
0.996 O
-20 -15 -10 -5 0 5 10 15 20
Phase angle in min.

OMICRON Page 19
Supported standards

> IEC 60044-2 (inductive VTs)


> IEC 60044-5 (capacitive VTs)
> IEC 61869-3 (additional requirements for inductive VTs)
> IEC 61869-5 (additional requirements for capacitive VTs)
> IEEE C57.13 (standard requirements for conventional transformers)
> ANSI C93.1 (requirements for capacitive VTs)
Simulation and re-assessment of results

> Simulation and re-assessment of existing measurement data at any time


> No further on-site measurement necessary when the following
transformer parameters have changed:
> Burdens
> Nominal voltage factor
> Accuracy class

OMICRON Page 21
Reporting

> Generate customized reports


> Data can be exported in Excel and XML format

OMICRON Page 22
Technical specifications
Inductive voltage transformers
Test restrictions for
Ratio measurement
inductive voltage
Voltage ratio Voltage level Typical accuracy transformers
1 ... 350 0.6kV ... 35kV 0.05% > Combined instrument
> 350 ... 1100 > 35kV ... 110kV 0.07% transformers cannot be
tested with the mentioned
> 1100 ... 2450 > 110kV ... 245kV 0.07%
accuracy

Phase displacement measurement


Voltage ratio Voltage level Typical accuracy
1 ... 350 0.6kV ... 35kV 1 min
> 350 ... 1100 > 35kV ... 110kV 2 min
> 1100 ... 2450 > 110kV ... 245kV 2 min

Winding resistance measurement


Resolution Guaranteed accuracy Typical accuracy
1m 0.1% + 1m 0.05%

> Detailed technical specifications

OMICRON Page 23
Technical specifications
Capacitive coupled voltage transformers
Test restrictions for
Ratio measurement
capacitive coupled
Voltage ratio Voltage level Typical accuracy voltage transformers
300 ... 8000 > 30kV ... 800kV 0.07% > CVTs with integrated
damping unit which cannot
be accessed from outside
Phase displacement measurement cannot be tested with the
Voltage ratio Voltage level Typical accuracy mentioned accuracy.

300 ... 8000 > 30kV ... 800kV 2 min > CVTs where the connection
of the NHF terminal to
ground cannot be opened
cannot be tested.
Winding resistance measurement
Resolution Guaranteed accuracy Typical accuracy
1m 0.1% + 1m 0.05%

> Detailed technical specifications

OMICRON Page 24
Ordering information and accessories

Ordering information Accessories


> VOTANO 100 Standard Package
(VE000800)
> VOTANO 100, VBO1, accessories
> Testing up to class 0.3

> VOTANO 100 Advanced Package


(VE000801)
> Content of Standard Package
> Increased accuracy: testing up
to class 0.1
> Simulation tool Dead man switch
> VOTANO 100 Capacitive VT
Upgrade Option (VESM0801)
> Standard to Advanced
Upgrade Option (VESM0802)

OMICRON Page 25
VOTANO 100

> Compact size and low weight (< 15 kg / 33 lbs)


> Field calibration of VTs up to the 0.1 accuracy class
> Software-guided test procedure ensures
short testing time (< 20 min)
> Automatic result assessment as per IEEE and
IEC standards directly after the test
> Simulation and re-assessment with changed VT parameters
> Local isolation between high voltage and measuring equipment

Thank you for your attention.