You are on page 1of 31

DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA

CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

TEMA: DETERMINACION DEL CAUDAL DE DISEO


Y DIAMETRO DE LA LINEA DE CONDUCCION DE
AGUA PARA CAMPO DE RIEGO, SOBRE LA BASE
DEL USO CONSUNTIVO DE LOS CULTIVOS

NDICE
1. INFORMACION BASICA ................................................................................................................................ 2

1.1 rea de estudio:........................................................................................................................................... 2

1.2 Climatologa, informacin de estacin meteorolgica........................................................................ 2

1.3 Superficie neta de riego: .......................................................................................................................... 3

1.4 Suelo predominante: .................................................................................................................................... 3

1.5 Cultivos: ........................................................................................................................................................... 3

1.6 Distancia de lnea de conduccin: ........................................................................................................... 3

1.7 Desnivel topogrfico para la elevacin del agua de riego: .............................................................. 3

2. DETERMINACION DEL USO CONSUNTIVO DE LOS CULTIVOS ................................................... 3

2.1 Definicin de fechas de siembra de los cultivos, periodos vegetativos y otras


caractersticas: ........................................................................................................................................................... 3

A. LA ZANAHORIA: .................................................................................................................................... 3

B. TOMATE: ................................................................................................................................................... 6

C. ARVEJA: .................................................................................................................................................... 9

2.2 ESTIMACIN DEL USO CONSUNTIVO DE LOS CULTIVOS: .................................................. 11

2.2.1 METODOS PARA LA ESTIMACIN DE LA EVAPOTRANSPIRACIN ......................... 12

Pgina 1
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

2.2.2 RESULTADOS DE LA ESTIMACIN DE LA EVAPOTRANSPIRACIN ........................ 13

2.2.3 USO CONSUNTIVO DE LOS CULTIVOS ................................................................................. 14

2.3 DETERMINACIN DEL MDULO DE RIEGO (M) POR CADA CULTIVO, M3/CAMPAA
POR LOS TRES MTODOS................................................................................................................................... 15

2.3.1 MODULO DE RIEGO SEGUN DAMIN VSQUEZ BERNAL .............................................. 15

2.3.2 MODULO DE RIEGO SEGUN BLANEY Y CRIDDLE ............................................................... 17

2.3.3 MODULO DE RIEGO SEGN IVANOV ...................................................................................... 18

2.3.4 Promedios de mdulo de riego de cada cultivo por m3/ha por campaa ......................... 19

2.4 DETERMINACIN DE LA DOSIS DE RIEGO (M) POR GRAVEDAD, POR CADA CULTIVO,
M3/RIEGO .................................................................................................................................................................. 20

2.5 DETERMINACIN DEL HIDROMDULO ........................................................................................... 22

3. DETERMINACIN DEL DIAMETRO DE LA LINEA DE CONDUCCION. ...................................... 25

3.1 DETERMINACIN DE LA CANTIDAD DE AGUA POR AO ....................................................... 26

3.2 DATOS PROPORCIONADOS PARA EL CALCULO ............................................................................ 26

3.3 DETERMINACIN DE PERDIDAS Y POTENCIA DE BOMBA...................................................... 26

3.4 DETERMINACIN DE COSTOS DE CONSTRUCCIN Y OPERACIN.................................... 28

DETERMINACIN DEL CAUDAL DE DISEO Y DIMETRO DE LA LNEA DE

CONDUCCIN DE AGUA PARA UN REA DE RIEGO

El esquema adoptado para el ejercicio de aplicacin de la Hidrologa Aplicada y conocimientos de

otras disciplinas es: Fuente de riego un canal, estacin de bombeo, lnea de conduccin por

tuberas, y el rea de siembra con sistema de riego por goteo para rotacin de cultivos.

1. INFORMACION BASICA

1.1 rea de estudio:

La zona geodsica de la ubicacin del rea de riego: 5 o50 14 S y 79o 49 8.5O; 120

m.s.n.m.

1.2 Climatologa, informacin de estacin meteorolgica.

Pgina 2
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

PARAM ETRO enero febrero marzo abril mayo junio julio agosto Septiem. octubre Noviemb. diciembre
Temperatura media, Grados Celcius C 26.4 27.3 27.4 26.2 24.1 22.7 21.6 22.0 22.9 23.5 24.0 25.4
Temperatura mxima absoluta, C 36.2 36.4 36.5 35.3 34.4 32.4 31.5 32.1 33.2 33.8 34.3 35.4
Temperatura mnima absoluta, C 17.3 18.5 18.3 16.7 14.7 13.1 11.3 11.8 12.8 13.0 13.3 14.6
Humedad Relativa del aire media, % 67.2 68.8 71.5 71.3 71.9 72.7 72.7 72.0 70.5 70.4 69.9 91.4
Precipitaciones, mm 12.9 29.7 110.0 34.0 12.1 4.6 0.2 0.2 1.0 3.3 2.7 4.4
Evaporacin Tanque, mm 6.7 6.1 5.9 5.6 5.2 4.6 4.6 5.1 6.2 6.7 6.7 6.9
Evaporacin Piche, mm 4.0 3.7 3.5 3.3 3.3 2.9 2.7 2.9 3.4 3.5 3.5 3.8
Velocidad media del Viento, m/s 1.3 1.1 1.1 1.1 1.2 1.2 1.4 1.5 1.7 1.7 1.6 1.5
Velocidad mxima del Viento, m/s 1.8 1.7 1.6 1.5 1.8 1.8 3.1 2.0 2.2 2.3 2.1 2.2

Cuadro N01
Fuente: Informacin Meteorolgica
1.3 Superficie neta de riego:

El rea neta de riego a estudiar es de 900 ha.

1.4 Suelo predominante:

El suelo predominante en el rea de estudio es arcillo arenoso medio.

1.5 Cultivos:

Los cultivos que se van a sembrar son:

La zanahoria. (ocupara un 50% del terreno).

El tomate. (ocupara un 22% del terreno).

La arveja. (ocupara un 28% del terreno).

1.6 Distancia de lnea de conduccin:

La lnea de conduccin tendr una longitud de 9 Km.

1.7 Desnivel topogrfico para la elevacin del agua de riego:

Se tiene un desnivel topogrfico de 25m.

2. DETERMINACION DEL USO CONSUNTIVO DE LOS CULTIVOS

2.1 Definicin de fechas de siembra de los cultivos, periodos vegetativos y otras

caractersticas:

A. LA ZANAHORIA:

Caractersticas

Pgina 3
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

Esta planta es muy conocida debido a su

raz, la cual es pivotante y almacena

grandes cantidades de azcares y

nutrientes para la floracin de la planta.

Esta raz mide aproximadamente 20

centmetros y es de color anaranjado. La

contextura interior de la raz de la

zanahoria tiene una consistencia carnosa y muy fibrosa. Las flores de la

zanahoria miden aproximadamente 5 milmetros y las hojas de la zanahoria,

crecen desde la raz de esta planta. Se agrupan en una roseta, la cual mide unos

30 centmetros de altura y son de un color verde claro, muy brillante.

Nombre cientfico: Daucus carota

Familia: Apiaceae

Origen: Europa y Asia sudoccidental.

Clima: La zanahoria es una hortaliza que se adapta a varios tipos de clima,

sin embargo, tiene preferencia por los climas templados. La temperatura

ptima de crecimiento de la zanahoria se encuentra entre los 15 y 21 C.

En poca lluviosa es preciso la elaboracin de camellones (surcos)

bastante altos y camas de siembra de aproximadamente 1.20 m de ancho

por 20 0 30 cm de alto para evitar que el exceso de humedad, producto

de las precipitaciones, favorezcan el desarrollo de enfermedades del

suelo que causen la muerte de las plntulas.

Humedad: el cultivo de la zanahoria requiere de humedad relativa o

humedad del aire de 70 u 80%.

Luminosidad: la zanahoria es un cultivo que requiere de buena iluminacin,

la cual ser modificada segn la densidad de siembra.

Altitud: la zanahoria se cultiva a una altitud promedio de 1200 msnm

Suelo: un suelo profundo, con una textura franco arenosa, bien aireados

y frescos, ricos en potasio, que mantengan la humedad con suficiente

porosidad para brindarle una buena aireacin.

FECHAS DE SIEMBRAS DE CULTIVO Y PERIODOS VEGETATIVOS

Pgina 4
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

ZANAHORIA
ZANAHORIA
ROTACION
ESTACION: GRANJA EXPERIMENTAL PASABAR (OLMOS) Fecha de inicio: 02/01/2016 ROTACION
01/07/2016
ESTACION:
PERIODO VEGETATIVO: 100 dias GRANJA EXPERIMENTAL PASABAR (OLMOS) Fecha de trmino:Fecha de inicio:
09/05/2016 02/01/2016
07/11/2016 01/07/2016
MES DE INICIO: Enero
PERIODO VEGETATIVO: 100 dias Fecha de trmino: 09/05/2016 07/11/2016
MES DE INICIO: Enero
FUENTE: RIEGO POR GOTEO 2013

FUENTE: RIEGO POR GOTEO 2013


FACTORES DE CULTVO ETAPAS DE CRECIMIENTO
FASE DE CULTIVO Kc PERIODO VEGETATIVO Dias
FACTORES DE CULTVO
INICAL 0.45 ETAPAS DE CRECIMIENTO
INICAL 20
DESARROLLO FASE DE CULTIVO 0.75 Kc DESARROLLO DEL CULTIVO
PERIODO VEGETATIVO 30 Dias
MITAD DE TEMPORADA INICAL 1.05 0.45 MITAD DE TEMPORADA INICAL 30 20
FINALES 0.90 FINAL DE TEMPRADA 20
DESARROLLO 0.75 DESARROLLO DEL CULTIVO 30
TOTAL 100
MITAD DE TEMPORADA 1.05 MITAD DE TEMPORADA 30
FINALES 0.90 FINAL DE TEMPRADA 20

0 0.45 TOTAL 100


20 0.45
50 0.75 Kc DE CULTVO POR MES
80 01.05 0.45
MES DIAS ACUM. MES DIS ACUM. Kc
100 200.90 0.45
ENE 2 2 JUL 1 1 0.45
FEB 28 30 AGOS 32 0.75
50 0.75 Kc31
DE CULTVO POR MES
MAR 31 61 SEPT 30 62 1.05
80 1.05 MES DIAS ACUM. MES DIS ACUM. Kc
ABR 30 91 OCT 31 93 1.00
100 0.90
MAY 9ENE 2
100 NOV2 JUL
7 1 100 1 0.90 0.45
FEB 28 30 AGOS 31 32 0.75
Cuadro N02
MARPeriodo de
31cultivo, fechas
61 de inicio ySEPT
termino de siembra
30 de la Zanahoria 62 1.05
ABR 30 Fuente:91
Elaboracin propia
OCT 31 93 1.00
MAY 9 100 NOV 7 100 0.90

Pgina 5
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

FASES DEL CULTIVO DE LA ZANAHORIA


1.20

1.05
1.00

0.90
0.80
0.75

Kc 0.60
0.45 0.45
0.40

K inicial K desarrollo del cultivo K mitad de estacion K final de temp


0.20

0.00
0 10 20 30 40 50 60 70 80 90 100

Tiempo (dias)

Grfica: N01 Fases del cultivo de la Zanahoria

Fuente: Elaboracin propia


B. TOMATE:

Caractersticas

Planta comestible oriunda de Amrica que

hoy es consumida en el mundo entero.

Entre sus principales propiedades

nutritivas cabe mencionar que tienen un

alto contenido de agua, bajo en hidratos

de carbono y caloras y con ricos aportes

de fibras, vitaminas y algunos minerales.

Su tallo con eje con un grosor que oscila entre 2-4 cm en su base, sobre el que se

van desarrollando hojas, tallos secundarios (ramificacin simpoidal) e

inflorescencias.

Nombre cientfico: Solanum lycopersicum.

Familia: Solanaceae.

Variedades :

Pgina 6
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

Tomate de ensalada: el que se usa para las ensaladas, se suele cosechar un


poco verde.
Tomate Cherry: es muy pequeo y se usa entero para adornar ensaladas.
Existen variedades de color rojo y otras de color amarillo.
Tomate de colgar, Tomate Montserrat Tomate de Pera,etc.
Temperatura: La temperatura ptima de desarrollo oscila entre 20 y 30C

durante el da y entre 1 y 17C durante la noche; temperaturas superiores a

los 30-35C afectan a la fructificacin. climticos.

Suelo: la planta de tomate no es muy exigente en cuanto a suelos, excepto

en lo que se refiere al drenaje, aunque prefiere suelos sueltos de textura

silceo-arcillosa y ricos en materia orgnica. No obstante se desarrolla

perfectamente en suelos arcillosos enarenados. En cuanto al PH, los suelos

pueden ser desde ligeramente cidos hasta ligeramente alcalinos cuando

estn enarenados. Es la especie cultivada en invernadero que mejor tolera

las condiciones de salinidad tanto del suelo como del agua de riego.

Marcos de plantacin: El marco de plantacin se establece en funcin del

porte de la planta, que a su vez depender de la variedad comercial cultivada.

El ms frecuentemente empleado es de 1,5 metros entre lneas y 0,5 metros

entre plantas, aunque cuando se trata de plantas de porte medio es comn

aumentar la densidad de plantacin a 2 plantas por metro cuadrado con

marcos de 1 m x 0,5 m.

Pgina 7
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

FECHAS DE SIEMBRAS DE CULTIVO Y PERIODOS VEGETATIVOS

TOMATE
ROTACION
ESTACION: GRANJA EXPERIMENTAL PASABAR (OLMOS) Fecha de inicio: 15/01/2016 13/07/2016
PERIODO VEGETATIVO: 135 dias Fecha de trmino: 31/05/2016 30/11/2016
MES DE INICIO: Enero

FUENTE: RIEGO POR GOTEO 2013

FACTORES DE CULTVO ETAPAS DE CRECIMIENTO


FASE DE CULTIVO Kc PERIODO Dias
INICAL 0.45 INICAL 30
DESARROLLO 0.75 DESARROLLO DEL CULTIVO 40
MITAD DE TEMPORADA 1.15 MITAD DE TEMPORADA 40
FINALES 0.80 FINAL DE TEMPRADA 25
TOTAL 135

Kc DE CULTVO POR MES


MES DIAS ACUM. MES DIS ACUM. Kc
ENE 15 15 JUL 13 13 0.45
FEB 28 43 AGOS 31 44 0.75
MAR 31 74 SEPT 30 74 1.15
ABR 30 104 OCT 31 105 1.00
MAY 31 135 NOV 30 135 0.80

Cuadro N03 Periodo de cultivo, fechas de inicio y termino de siembra del tomate

Fuente: Elaboracin propia

FASES DEL CULTIVO DEL TOMATE


1.4

1.2
1.15
1

0.8
0.75 0.75
Kc
0.6

0.4
0.45 0.45

0.2 K inicial K desarrollo del cultivo k mitad de temp final de temp

0
0 15 30 45 60 75 90 105 120 135

Tiempo (dias)

Grfica: N02 Fases del cultivo del tomate

Fuente: Elaboracin propia

Pgina 8
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

C. ARVEJA:

Caractersticas

La planta posee un sistema vegetativo poco


desarrollado aunque con una raz pivotante
que tiende a profundizar bastante. Las
hojas estn formadas por pares de fololos
terminadas en zarcillos. Las semillas
(guisantes) se encuentran en vainas de
entre 5 a 10 cm de largo que contienen
entre 4 y 10 unidades.

Se distinguen cultivares de plantas bajas,


determinadas o enanas (0,5 a 0,7 m de altura), intermedias o semideterminadas (0,7 a
1,0 m), y altas, indeterminadas o guiadoras (ms de 1,0 m, pudiendo llegar hasta 3m que
se comportan como enredaderas que no dejan de crecer y requieren medios de soporte
o "guas".

Nombre cientfico: Pisum sativum.

Familia: Fabaceae.

Variedades: Se pueden diferenciar entre las de Grano Verde: Onward Cuarentona, Cobr,
Mikad; y las que se usan para grano Seco: Cobr y Mikado.

Altitud: La planta de arveja se adapta mejor a las condiciones de la sierra y a los valles
interandinos, necesita para su mejor desarrollo condiciones ambientales, como climas
fros, son pocos resistentes a las sequas y muy sensibles al calor. Se siembra hasta los
3.300 m.s.n.m.

Temperatura: Es una especie que resiste bien al fro pero prospera bien en climas
templado caliente y hmedo, con temperaturas entre los 15 a 18C, pudiendo soportar
un alto rango de temperatura de 7 a 24C.

Suelo: La arveja se adapta a diferentes tipos de suelo, puede sembrarse en suelos


francos arenosos a franco arcillosos, pero prefiere los suelos sueltos, profundos y bien
drenados, provistos de caliza y abundante materia orgnica.

Pgina 9
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

FECHAS DE SIEMBRAS DE CULTIVO Y PERIODOS VEGETATIVOS

ARVEJA
ROTACION
ESTACION: GRANJA EXPERIMENTAL PASABAR (OLMOS) Fecha de inicio: 31/01/2016 30/07/2016
PERIODO VEGETATIVO: 150 dias Fecha de trmino: 30/05/2016 28/11/2016
MES DE INICIO: Enero

FUENTE: RIEGO POR GOTEO 2013

FACTORES DE CULTVO ETAPAS DE CRECIMIENTO


FASE DE CULTIVO Kc PERIODO Dias
INICAL 0.35 INICAL 30
DESARROLLO 0.75 DESARROLLO DEL CULTIVO 40
MEDIA ESTACION 1.10 MITAD DE TEMPORADA 50
FINALES 0.30 FINAL DE TEMPRADA 30
TOTAL 150

Kc DE CULTVO POR MES


MES DIAS ACUM. MES DIS ACUM. Kc
ENE 31 31 JUL 30 30 0.35
FEB 28 59 AGOS 31 61 0.75
MAR 31 90 SEPT 30 91 1.10
ABR 30 120 OCT 31 122 0.70
MAY 30 150 NOV 28 150 0.30
Cuadro N04 Periodo de cultivo, fechas de inicio y termino de siembra de la arveja.

Fuente: Elaboracin propia

FASES DEL CULTIVO DE LA ARVEJA


1.20

1.10
1.00

0.80
0.75

Kc 0.60

0.40
0.35 0.35
0.30
0.20 k inicial k desarrollo del cultivo k mitad de temp k final de temp

0.00
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150

Tiempo (dias)

Grfica: N03 Fases del cultivo de la arveja.

Fuente: Elaboracin propia

Pgina 10
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

PERIODO
MESES
CULTIVO VEGETATIV
O Das ENE FEB MAR ABR MAY JUN JUL AGO SEP OCT NOV DIC
Zanahoria 100 2 28 31 30 9 1 31 30 31 7
Tomate 135 15 28 31 30 31 13 31 30 31 30
Arv eja 150 31 28 31 30 30 31 30 31 30 28
TOTAL

CUADRO 05. Resumen de los Periodos de cultivo y meses de siembra de los cultivos

Fuente: Elaboracin Propia

rea por cultivo, ha rea Semb.


Total rea
CULTIVO en
Principal Rotacin Sembr. Ha
%
Zanahoria 450 450 50
Tomate 200 200 200 22
Arv eja 250 250 250 28
900.00 450.00 1350.00 100
CUADRO 06. Resumen de los reas a sembrar por cultivo

Fuente: Elaboracin Propia

2.2 ESTIMACIN DEL USO CONSUNTIVO DE LOS CULTIVOS:

El consumo de agua de los cultivos o evapotranspiracin: es la suma del agua

transpirada por las plantas, a travs de sus estomas y del agua que se evapora del suelo.

La evapotranspiracin: depende del clima, de las prcticas de riego, del periodo

vegetativo de los cultivos y de otros factores.

En la evapotranspiracin adems como se dijo antes, se considera el agua que se evapora

del terreno adyacente a las plantas, de la superficie libre de agua y de la superficie de

las hojas.

El consumo de agua de una planta durante su ciclo vegetativo es irregular, si se hace un

grfico con las consumos mensuales, generalmente se obtiene una curva parablica,

correspondiendo el vrtice a la flotacin, lo cual hay que tener en cuenta para calcular

las necesidades de agua - de los cultivos.

La evapotranspiracin puede ser potencial y real:

La evapotranspiracin potencial: se define como la mxima evapotranspiracin

posible que se produce en condiciones favorables, teniendo el suelo un contenido

de humedad a nivel de capacidad de campo, cubierto con vegetacin densa,

uniforme y tamao pequeo.

Pgina 11
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

La evapotranspiracin real: tambin llamada actual es aquella que se produce en

condiciones dadas reales del medio. Hay varios mtodos para determinar la

cantidad de agua consumida por los cultivos entre ellos se tiene experimentos en

tanques y lismetros, parcelas en el campo, estudios de humedad del suelo, etc.

2.2.1 METODOS PARA LA ESTIMACIN DE LA EVAPOTRANSPIRACIN

Con la informacin meteorolgica descrito anteriormente en el CUADRO

N07 , datos obtenidos en campo para determinar la evapotranspiracin.


PARMETRO Unidad Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre Noviembre Diciembre
Temperatura media C 26.39 27.31 27.38 26.18 24.14 22.68 21.62 22.02 22.85 23.46 23.99 25.36
Temperatura mxima absoluta C 36.18 36.43 36.54 35.26 34.42 32.40 31.54 32.09 33.21 33.78 34.28 35.42
Temperatura mnima absoluta C 17.30 18.50 18.27 16.67 14.74 13.10 11.25 11.78 12.79 13.04 13.33 14.64
Humedad Relativa del aire media % 67.16 68.77 71.45 71.29 71.94 72.68 72.69 71.97 70.47 70.44 69.88 91.38
Precipitaciones mm 12.88 29.71 109.97 33.96 12.10 4.63 0.23 0.23 1.04 3.26 2.67 4.36
Evaporacin del Tanque mm 6.72 6.11 5.86 5.63 5.24 4.63 4.55 5.11 6.16 6.69 6.69 6.91
Evaporacin Piche mm 4.01 3.65 3.50 3.29 3.27 2.87 2.71 2.91 3.37 3.51 3.51 3.80
Velocidad media del Viento m/s 1.28 1.09 1.08 1.07 1.19 1.19 1.43 1.48 1.70 1.73 1.62 1.50
Velocidad mxima del Viento m/s 1.80 1.70 1.60 1.50 1.80 1.80 3.10 2.00 2.20 2.30 2.10 2.20
CUADRO 07. Informacin meteorolgica

Fuente: Elaboracin Propia

2.2.1.1 EVAPOTRANSPIRACIN SEGN EL ING DAMIN VSQUEZ

BERNAL.

= .

Dnde:

Evp: Evapotranspiracin potencial media mensual (m3/ha)


t: Temperatura media del mes (C)

2.2.1.2 EVAPOTRANSPIRACIN SEGN BLANEY Y CRIDDLE

= (. + . )

Pgina 12
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

Dnde:

Evp: Evapotranspiracin potencial referencial (mm/mes)

Tm: Temperatura media diaria (C)

p: (%) diario de horas de luz mes con respecto al anual

% De horas luz, Latitud Sur

Latitud
Sur
Enero Febrero Marzo Abril Mayo Junio
8.68 7.76 8.51 8.15 8.34 8.05
5 Julio Agosto Septiembre Octubre Noviembre Diciembre
8.33 8.38 8.19 8.56 8.37 8.68
CUADRO 07.: Porcentaje de horas de Luz en la zona Latitud Sur

Fuente: Evaporacin.

2.2.1.3 EVAPOTRANSPIRACIN SEGN IVANOV


(

) = . ( + ) *(100-HR)

Dnde:

Evp: Evapotranspiracin potencial referencial (mm/mes)

T: Temperatura media del mes (C).

HR: Humedad Relativa del aire media

2.2.2 RESULTADOS DE LA ESTIMACIN DE LA EVAPOTRANSPIRACIN

Pgina 13
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

La evapotranspiracin ser calculada con la ayuda de los tres mtodos mencionados


anteriormente (IVANOV, DVB y BLANEY Y CRIDDLE).

Ivanov Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre NoviembreDiciembre
t (C) 26.39 27.31 27.38 26.18 24.14 22.68 21.62 22.02 22.85 23.46 23.99 25.36
Humedad Relativa 67.16 68.77 71.45 71.29 71.94 72.68 72.69 71.97 70.47 70.44 69.88 91.38
EVp (mm/mes) 156.11 153.83 141.00 135.35 121.99 111.82 106.87 111.57 121.72 124.98 130.14 39.37
EVp (m3/ha) 1561.07 1538.26 1410.01 1353.50 1219.93 1118.17 1068.67 1115.69 1217.16 1249.76 1301.44 393.70

Blaney - Criddle Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre NoviembreDiciembre
Tm(C) 26.39 27.31 27.38 26.18 24.14 22.68 21.62 22.02 22.85 23.46 23.99 25.36
p (%) 8.68 7.76 8.51 8.15 8.34 8.05 8.33 8.38 8.19 8.56 8.37 8.68
EVp (mm/mes) 175.94 160.59 176.38 164.40 160.42 149.44 150.58 153.03 152.68 161.98 160.42 171.82
EVp (m3/ha) 1759.40 1605.91 1763.77 1643.99 1604.22 1494.39 1505.80 1530.25 1526.76 1619.79 1604.17 1718.17

Vsquez Bernal Enero Febrero Marzo Abril Mayo Junio Julio Agosto Septiembre Octubre NoviembreDiciembre
Dias 31 28 31 30 31 30 31 31 30 31 30 31
t (C) 26.39 27.31 27.38 26.18 24.14 22.68 21.62 22.02 22.85 23.46 23.99 25.36
t (C) 818.10 764.81 848.85 785.32 748.40 680.47 670.33 682.73 685.55 727.34 719.72 786.09
EVp (m3/ha) 1808.00 1690.22 1875.96 1735.56 1653.96 1503.83 1481.42 1508.83 1515.06 1607.42 1590.58 1737.26

CUADRO 08.: Calculo de la Evatranspiracin

Fuente: Elaboracin propia

EVp 5128.46 4834.39 5049.74 4733.05 4478.12 4116.39 4055.88 4154.77 4258.97 4476.96 4496.19 3849.13
PROMEDIO (m3/ha) 1709.49 1611.46 1683.25 1577.68 1492.71 1372.13 1351.96 1384.92 1419.66 1492.32 1498.73 1283.04
PROMEDIO (mm/dia) 5.51 5.76 5.43 5.26 4.82 4.57 4.36 4.47 4.73 4.81 5.00 4.14

CUADRO 09: Promedio de la 3 frmulas para el clculo Evatranspiracin

Fuente: Elaboracin propia

2.2.3 USO CONSUNTIVO DE LOS CULTIVOS

CULTIVO DE LA ZANAHORIA
MESES Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
DIAS 31 28 30 30 31 30 31 31 30 31 30 31
EVp 5128.46 4834.39 5049.74 4733.05 4478.12 4116.39 4055.88 4154.77 4258.97 4476.96 4496.19 3849.13
EV PROMEDIO (m3/ha) 1709.49 1611.46 1683.25 1577.68 1492.71 1372.13 1351.96 1384.92 1419.66 1492.32 1498.73 1283.04
EV PROMEDIO (mm/dia) 5.51 5.76 5.43 5.26 4.82 4.57 4.36 4.47 4.73 4.81 5.00 4.14
KC 0.45 0.75 1.05 1.00 0.90 0.00 0.45 0.75 1.05 1.00 0.90 0.00
USO CONSUNTIVO (mm) 76.93 120.86 171.04 157.77 134.34 0.00 60.84 103.87 149.06 149.23 134.89 0.00

CUADRO 10: Uso consuntivo de la zanahoria

Fuente: Elaboracin propia

Pgina 14
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

CULTIVO DEL TOMATE


MESES Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
DIAS 31 28 30 30 31 30 31 31 30 31 30 31
EVp 5128.46 4834.39 5049.74 4733.05 4478.12 4116.39 4055.88 4154.77 4258.97 4476.96 4496.19 3849.13
EV PROMEDIO (m3/ha) 1709.49 1611.46 1683.25 1577.68 1492.71 1372.13 1351.96 1384.92 1419.66 1492.32 1498.73 1283.04
EV PROMEDIO (mm/dia) 5.51 5.76 5.43 5.26 4.82 4.57 4.36 4.47 4.73 4.81 5.00 4.14
KC 0.45 0.75 1.15 1.00 0.80 0.00 0.45 0.75 1.15 1.00 0.80 0.00
USO CONSUNTIVO (mm) 76.93 120.86 187.33 157.77 119.42 0.00 60.84 103.87 163.26 149.23 119.90 0.00
CUADRO 11: Uso consuntivo del tomate

Fuente: Elaboracin propia

CULTIVO ARVEJA
MESES Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
DIAS 31 28 30 30 31 30 31 31 30 31 30 31
EVp 5128.46 4834.39 5049.74 4733.05 4478.12 4116.39 4055.88 4154.77 4258.97 4476.96 4496.19 3849.13
EV PROMEDIO (m3/ha) 1709.49 1611.46 1683.25 1577.68 1492.71 1372.13 1351.96 1384.92 1419.66 1492.32 1498.73 1283.04
EV PROMEDIO (mm/dia) 5.51 5.76 5.43 5.26 4.82 4.57 4.36 4.47 4.73 4.81 5.00 4.14
KC 0.35 0.75 1.10 0.70 0.30 0.00 0.35 0.75 1.10 0.70 0.30 0.00
USO CONSUNTIVO (mm) 59.83 120.86 179.18 110.44 44.78 0.00 47.32 103.87 156.16 104.46 44.96 0.00

CUADRO 12: Uso consuntivo de la arveja

Fuente: Elaboracin propia

2.3 DETERMINACIN DEL MDULO DE RIEGO (M) POR CADA CULTIVO,

M3/CAMPAA POR LOS TRES MTODOS.

Para determinar la Evapotranspiracin real de cada cultivo, se toma en cuenta los


coeficientes Kc de cada cultivo y se aplica la siguiente relacin:

EVr = kc*EVp

Del mismo modo el Mdulo de Riego se determin de la siguiente manera, en el


que se consider solo el factor de EVr, sin considerar Precipitaciones u otro:

Mod. Riego por mes = EVr / Eficiencia (90% en goteo)

2.3.1 MODULO DE RIEGO SEGUN DAMIN VSQUEZ BERNAL

CULTIVO ZANAHORIA
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.45 0.75 1.05 1.00 0.90 0.00 0.45 0.75 1.05 1.00 0.90 0.00
EVr (m3/ha) 813.90 1266.99 1971.03 1737.06 1485.98 0.00 665.92 1130.42 1594.18 1609.99 1432.08 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 904.33 1407.77 2190.04 1930.07 1651.09 0.00 739.91 1256.02 1771.32 1788.87 1591.20 0.00
Primera campaa 8083.30 m 3/ha
Segunda campaa 7147.31 m 3/ha

CUADRO 13: Mdulo de Riego y Evapotranspiracin real de la zanahoria

Fuente: Elaboracin propia

Pgina 15
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

CULTIVO TOMATE
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.45 0.75 1.15 1.00 0.80 0.00 0.45 0.75 1.15 1.00 0.80 0.00
EVr (m3/ha) 813.90 1266.99 2158.75 1737.06 1320.87 0.00 665.92 1130.42 1746.01 1609.99 1272.96 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 904.33 1407.77 2398.61 1930.07 1467.64 0.00 739.91 1256.02 1940.01 1788.87 1414.40 0.00
Primera campaa 8108.42 m 3/ha
Segunda campaa 7139.21 m 3/ha

CUADRO 14: Mdulo de Riego y Evapotranspiracin real del tomate

Fuente: Elaboracin propia

CULTIVO ARVEJA
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.35 0.75 1.10 0.70 0.30 0.00 0.35 0.75 1.10 0.70 0.30 0.00
EVr (m3/ha) 633.03 1266.99 2064.89 1215.94 495.33 0.00 517.94 1130.42 1670.10 1126.99 477.36 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 703.37 1407.77 2294.32 1351.05 550.36 0.00 575.48 1256.02 1855.66 1252.21 530.40 0.00
Primera campaa 4771.22 m 3/ha
Segunda campaa 4341.64 m 3/ha

CUADRO 15: Mdulo de Riego y Evapotranspiracin real de la arveja

Fuente: Elaboracin propia

Grfica: N04 Evapotranspiracin Real De Cada Cultivo

Fuente: Elaboracin propia

Pgina 16
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

2.3.2 MODULO DE RIEGO SEGUN BLANEY Y CRIDDLE

CULTIVO ZANAHORIA
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.45 0.75 1.05 1.00 0.90 0.00 0.45 0.75 1.05 1.00 0.90 0.00
EVr (m3/ha) 791.90 1204.04 1852.69 1644.83 1442.35 0.00 677.20 1147.01 1605.01 1621.26 1444.08 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 879.89 1337.82 2058.54 1827.59 1602.61 0.00 752.45 1274.46 1783.35 1801.40 1604.53 0.00
Primera campaa 7706.46 m 3/ha
Segunda campaa 7216.19 m 3/ha

CUADRO 16 Mdulo de Riego y Evapotranspiracin real de la zanahoria

Fuente: Elaboracin propia

CULTIVO TOMATE
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.45 0.75 1.15 1.00 0.80 0.00 0.45 0.75 1.15 1.00 0.80 0.00
EVr (m3/ha) 791.90 1204.04 2029.13 1644.83 1282.09 0.00 677.20 1147.01 1757.87 1621.26 1283.62 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 879.89 1337.82 2254.59 1827.59 1424.55 0.00 752.45 1274.46 1953.19 1801.40 1426.25 0.00
Primera campaa 7724.45 m 3/ha
Segunda campaa 7207.75 m 3/ha

CUADRO 17: Mdulo de Riego y Evapotranspiracin real del tomate

Fuente: Elaboracin propia

CULTIVO ARVEJA
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.35 0.75 1.10 0.70 0.30 0.00 0.35 0.75 1.10 0.70 0.30 0.00
EVr (m3/ha) 615.92 1204.04 1940.91 1151.38 480.78 0.00 526.71 1147.01 1681.44 1134.88 481.36 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 684.36 1337.82 2156.57 1279.31 534.20 0.00 585.24 1274.46 1868.27 1260.98 534.84 0.00
Primera campaa 4555.32 m 3/ha
Segunda campaa 4348.45 m 3/ha

CUADRO 18: Mdulo de Riego y Evapotranspiracin real de la arveja

Fuente: Elaboracin propia

Pgina 17
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

Grfica: N05 Evapotranspiracin Real De Cada Cultivo

Fuente: Elaboracin propia

2.3.3 MODULO DE RIEGO SEGN IVANOV

CULTIVO ZANAHORIA
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.45 0.75 1.05 1.00 0.90 0.00 0.45 0.75 1.05 1.00 0.90 0.00
EVr (m3/ha) 702.48 1153.70 1480.51 1353.50 1097.94 0.00 480.90 836.77 1278.01 1249.76 1171.30 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 780.53 1281.89 1645.01 1503.89 1219.93 0.00 534.33 929.74 1420.02 1388.62 1301.44 0.00
Primera campaa 6431.25 m3/ha
Segunda campaa 5574.15 m3/ha

CUADRO 19: Mdulo de Riego y Evapotranspiracin real de la zanahoria

Fuente: Elaboracin propia

CULTIVO TOMATE
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.45 0.75 1.15 1.00 0.80 0.00 0.45 0.75 1.15 1.00 0.80 0.00
EVr (m3/ha) 702.48 1153.70 1621.51 1353.50 975.94 0.00 480.90 836.77 1399.73 1249.76 1041.16 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 780.53 1281.89 1801.68 1503.89 1084.38 0.00 534.33 929.74 1555.26 1388.62 1156.84 0.00
Primera campaa 6452.37 m 3/ha
Segunda campaa 5564.79 m 3/ha

CUADRO 20: Mdulo de Riego y Evapotranspiracin real del tomate

Fuente: Elaboracin propia

Pgina 18
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

CULTIVO ARVEJA
PARMETROS Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Kc 0.35 0.75 1.10 0.70 0.30 0.00 0.35 0.75 1.10 0.70 0.30 0.00
EVr (m3/ha) 546.37 1153.70 1551.01 947.45 365.98 0.00 374.03 836.77 1338.87 874.83 390.43 0.00
Eficiencia (x goteo) 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90
Md. de riego (m3/ha) 607.08 1281.89 1723.35 1052.72 406.64 0.00 415.59 929.74 1487.64 972.03 433.81 0.00
Primera campaa 3598.30 m 3/ha
Segunda campaa 3500.56 m 3/ha

CUADRO 21: Mdulo de Riego y Evapotranspiracin real de la arveja

Fuente: Elaboracin propia

Grfica: N06 Evapotranspiracin Real De Cada Cultivo

Fuente: Elaboracin propia

2.3.4 Promedios de mdulo de riego de cada cultivo por m3/ha por campaa

CULTIVO ZANAHORIA
MDULO DE RIEGO
FRMULA
Campaa 1 Campaa 2
Ivanov 6431.25 5574.15
Blaney Criddle 7706.46 7216.19
DVB 8083.30 7147.31
PROMEDIO 7407.00 6645.88

CUADRO 22: Promedio Mdulo de Riego de la zanahoria por campaa

Fuente: Elaboracin propia

Pgina 19
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

CULTIVO TOMATE
MDULO DE RIEGO
FRMULA
Campaa 1 Campaa 2
Ivanov 6452.37 5564.79
Blaney Criddle 7724.45 5564.79
DVB 8108.42 7139.21
PROMEDIO 7428.41 6089.60

CUADRO 23: Promedio Mdulo de Riego del tomate por campaa

Fuente: Elaboracin propia

CULTIVO ARVEJA
MDULO DE RIEGO
FRMULA
Campaa 1 Campaa 2
Ivanov 3598.30 3500.56
Blaney Criddle 7207.75 4348.45
DVB 7139.21 4341.64
PROMEDIO 5981.75 4063.55

CUADRO 24: Promedio Mdulo de Riego de la arveja por campaa

Fuente: Elaboracin propia

2.4 DETERMINACIN DE LA DOSIS DE RIEGO (M) POR GRAVEDAD, POR

CADA CULTIVO, M3/RIEGO

Se aplic la siguiente frmula para la determinacin de la dosis de riego:

= ( ), 3/

Dnde:

H: profundidad de la capa humedecida (m).

:masa volumtrica de la capa humedecida (t/m3).

max: humedad del lmite superior (de la capacidad de campo), en % del peso del
suelo seco.

min: humedad del lmite inferior (del punto de marchitez), en % del peso del
suelo seco.

Pgina 20
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

Los resultados se obtuvieron mediante los siguientes datos:

VALORES DE CAPACIDAD DE CAMPO

% del Peso del Suelo


Composicin Mecnica del suelo m3/ha
Seco

Areno arcilloso muy ligero 6 12 1500 2100


Arcillo Arenoso ligero 13 20 1800 2800
Arcillo Arenoso medio 19 25 2100 3500
Arcillo Arenoso pesado 22 28 3000 4000

CUADRO 25. Valores de la Capacidad de Campo

Fuente: Del docente

Capa del suelo donde se localiza la principal


mas radicular del cultivo
Cultivo Capa Activa H,m
Hortalizas 0.50 0.70
Cereales y otros 0.70 1.00
Frutales 1.00 1.20

CUADRO 26. Capa Activa

Fuente: Del docente

Mediante la aplicacin de la frmula se obtuvo los siguientes resultados respecto a la dosis de


riego por gravedad:

CULTIVO DE ZANAHORIA

Tipo de suelo Arcillo Arenoso Medio


H 0.70 m
1.3 Tn/m3
max 25 %
min 19 %
Dosis de Riego 5.46 m3/ha

CUADRO 27. Dosis de Riego en m3/ha en zanahoria

Fuente: Elaboracin Propia

Pgina 21
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

CULTIVO DE TOMATE

Tipo de suelo Arcillo Arenoso Medio


H 0.70 m
1.3 Tn/m3
max 25 %
min 19 %
Dosis de Riego 5.46 m3/ha

CUADRO 28. Dosis de Riego en m3/ha en tomate

Fuente: Elaboracin Propia

CULTIVO DE ARVEJA

Tipo de suelo Arcillo Arenoso Medio


H 0.70 m
1.3 Tn/m3
max 25 %
min 19 %
Dosis de Riego 5.46 m3/ha
CUADRO 29. Dosis de Riego en m3/ha en Arveja

Fuente: Elaboracin Propia

2.5 DETERMINACIN DEL HIDROMDULO

Para determinar el hidromdulo de cada cultivo en los diferentes meses del ao, se aplic la
siguiente frmula :

q = x m /86.4 t

Dnde:

: % del rea ocupada por el cultivo

m: dosis de riego (m3/ha)

t: duracin de riego (da)

Pgina 22
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

CULTIVO DE LA ZANAHORIA
MESES Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
DIAS 31 28 30 30 31 30 31 31 30 31 30 31
EVp 5128.46 4834.39 5049.74 4733.05 4478.12 4116.39 4055.88 4154.77 4258.97 4476.96 4496.19 3849.13
EV PROMEDIO (m3/ha) 1709.49 1611.46 1683.25 1577.68 1492.71 1372.13 1351.96 1384.92 1419.66 1492.32 1498.73 1283.04
EV PROMEDIO (mm/dia) 5.51 5.76 5.43 5.26 4.82 4.57 4.36 4.47 4.73 4.81 5.00 4.14
KC 0.45 0.75 1.05 1.00 0.90 0.00 0.45 0.75 1.05 1.00 0.90 0.00
USO CONSUNTIVO (mm) 76.93 120.86 171.04 157.77 134.34 0.00 60.84 103.87 149.06 149.23 134.89 0.00
EFIC. (x gravedad) 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
NORMA IRRIGA. (m3/ha) 384.63 604.30 855.20 788.84 671.72 0.00 304.19 519.35 745.32 746.16 674.43 0.00

CULTIVO DEL TOMATE


MESES Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
DIAS 31 28 30 30 31 30 31 31 30 31 30 31
EVp 5128.46 4834.39 5049.74 4733.05 4478.12 4116.39 4055.88 4154.77 4258.97 4476.96 4496.19 3849.13
EV PROMEDIO (m3/ha) 1709.49 1611.46 1683.25 1577.68 1492.71 1372.13 1351.96 1384.92 1419.66 1492.32 1498.73 1283.04
EV PROMEDIO (mm/dia) 5.51 5.76 5.43 5.26 4.82 4.57 4.36 4.47 4.73 4.81 5.00 4.14
KC 0.45 0.75 1.15 1.00 0.80 0.00 0.45 0.75 1.15 1.00 0.80 0.00
USO CONSUNTIVO (mm) 76.93 120.86 187.33 157.77 119.42 0.00 60.84 103.87 163.26 149.23 119.90 0.00
EFIC. (x gravedad) 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
NORMA IRRIGA. (m3/ha) 384.63 604.30 936.65 788.84 597.08 0.00 304.19 519.35 816.30 746.16 599.49 0.00

CULTIVO ARVEJA
MESES Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
DIAS 31 28 30 30 31 30 31 31 30 31 30 31
EVp 5128.46 4834.39 5049.74 4733.05 4478.12 4116.39 4055.88 4154.77 4258.97 4476.96 4496.19 3849.13
EV PROMEDIO (m3/ha) 1709.49 1611.46 1683.25 1577.68 1492.71 1372.13 1351.96 1384.92 1419.66 1492.32 1498.73 1283.04
EV PROMEDIO (mm/dia) 5.51 5.76 5.43 5.26 4.82 4.57 4.36 4.47 4.73 4.81 5.00 4.14
KC 0.35 0.75 1.10 0.70 0.30 0.00 0.35 0.75 1.10 0.70 0.30 0.00
USO CONSUNTIVO (mm) 59.83 120.86 179.18 110.44 44.78 0.00 47.32 103.87 156.16 104.46 44.96 0.00
EFIC. (x gravedad) 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50
NORMA IRRIGA. (m3/ha) 1196.64 2417.20 3583.69 2208.76 895.62 0.00 946.37 2077.38 3123.25 2089.25 899.24 0.00
CUADRO 30. Datos utilizados para la determinacin del Hidromdulo

Fuente: Elaboracin Propia

rea por cultivo, ha rea Semb.


PERIODOVEG Total rea
CULTIVO en
ETATIVO Principal Rotacin Sembr. Ha
%
Zanahoria 100 450 450 50
Tomate 135 200 200 200 22
Arveja 150 250 250 250 28
900.00 450.00 1350.00 100

CUADRO 31. Porcentaje de reas por cultivo

Fuente: Elaboracin Propia

Pgina 23
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

El cuadro 32 muestra los resultados obtenidos para el hidromdulo de cada cultivo:

31 28 30 30 31 30 31 31 30 31 30 31
Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Zanahoria 0.07 0.12 0.16 0.15 0.13 0.00 0.06 0.10 0.14 0.14 0.13 0.00
Tomate 0.03 0.06 0.08 0.07 0.05 0.00 0.03 0.04 0.07 0.06 0.05 0.00
Arveja 0.12 0.28 0.38 0.24 0.09 0.00 0.10 0.22 0.33 0.22 0.10 0.00
CUADRO 32. Hidromdulo de los cultivos a lo largo de los meses del ao

Fuente: Elaboracin Propia

Grfica: N07 Hidromdulo de los Cultivos en los meses del ao

Fuente: Elaboracin propia

Pgina 24
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

3. DETERMINACIN DEL DIAMETRO DE LA LINEA DE CONDUCCION.

Para esto se aplic un promedio ponderado de del Uso Consuntivo de los tres cultivos y se
determin el requerimiento de agua en el siguiente cuadro:

31 28 30 30 31 30 31 31 30 31 30 31
Variable Unidad Ene Feb Mar Abr May Jun Jul Ago Sep Oct Nov Dic
Eto mm 170.95 161.15 162.89 157.77 149.27 137.21 135.20 138.49 141.97 149.23 149.87 128.30
FACTOR Kc PONDERADO 0.42 0.75 1.09 0.92 0.71 0.00 0.42 0.75 1.09 0.92 0.71 0.00
Uso Consuntivo mm 72.18 120.86 176.92 144.62 106.15 0.00 57.08 103.87 154.19 136.80 106.58 0.00
Precipitaciones. mm 12.9 29.7 110.0 34.0 12.1 4.6 0.2 0.2 1.0 3.3 2.7 4.4
Precipitacin Efectiva mm 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Requerimiento en lmina mm 72.18 120.86 176.92 144.62 106.15 0.00 57.08 103.87 154.19 136.80 106.58 0.00
3 721.8 1208.6 1769.2 1446.2 1061.5 0.0 570.8 1038.7 1541.9 1368.0 1065.8 0.0
Req. Volum. m /ha
Efic. Riego (por goteo) Ahorro 35% 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.65
N Horas de Riego horas 24 24 24 24 24 24 24 24 24 24 24 24
Hidromdulo, para el riego l/s /ha 0.41 0.77 1.05 0.86 0.61 0.00 0.33 0.60 0.92 0.79 0.63 0.00
rea Total ha 900 900 900 900 900 900 900 900 900 900 900 900
3 0.373 0.450 0.614 0.502 0.357 0.000 0.192 0.349 0.535 0.460 0.370 0.000
Q demanda Bruta m /s
Vol. Bruto mm/mes mmc 1.00 1.09 1.59 1.30 0.96 0.00 0.51 0.93 1.39 1.23 0.96 0.00

CUADRO 33. Requerimiento de Agua

Fuente: Elaboracin Propia

Caudal de mxima demanda y de diseo considerando un bombeo de 20 horas.

MAXIMO CAUDAL 0.614 m3/s (Caudal de diseo para el bombeo, operando las 24 horas del da)
HORAS DE BOMBEO 20 hrs

CAUDAL DE DISEO PARA


EL SISTEMA DE BOMBBEO 0.737 m3/s

CUADRO 34. Caudal de mxima demanda y Caudal de diseo

Fuente: Elaboracin Propia

Pgina 25
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

3.1 DETERMINACIN DE LA CANTIDAD DE AGUA POR AO

El cuadro 35 muestra la cantidad necesaria por ao utilizada en los 3 cultivos,


resultado de las dos campaas realizadas por cada uno:

CULTIVO ETC (m3/ha) REA (ha) CANTIDAD (m3)


Zanahoria 14052.89 450 6,323,799
Tomate 13518.01 200 2,703,601
Arveja 10045.31 250 2,511,327
Total 11,538,726

CUADRO 35. Cantidad de Agua por ao

Fuente: Elaboracin Propia

3.2 DATOS PROPORCIONADOS PARA EL CALCULO

Longitud de tuberia 9000 m


Desnivel topografico (Z) 25 m
Presion salida 2m
Coeficiente de rugosidad (n) 0.01
Eficiencia de la bomba 75%
Costo de energa (KW/h) 0.070 US$
Caudal de diseo (m3/seg) 0.737
CUADRO 36. Datos utilizados para la determinacin de la Lnea de Conduccin

Fuente: Elaboracin Propia

3.3 DETERMINACIN DE PERDIDAS Y POTENCIA DE BOMBA

Para el anlisis se considera que la velocidad del agua debe oscilar entre 0.7 y 1.7

m/s, por lo cual obtendremos tuberas con dimetros diferentes y cada uno de

estos se le har el anlisis respectivo.

Para el clculo de las perdidas por friccin se utilizara la frmula de Manning,

esta suele ser utilizada en canales, para el caso de las tuberas son vlidas cuando

el canal es circular y est parcial o totalmente lleno, o cuando el dimetro de la

tubera es muy grande. Uno de los inconvenientes de la frmula es que solo tiene

en cuenta un coeficiente de rugosidad (n) obtenido empricamente, y no las

variaciones de viscosidad con la temperatura. La expresin es la siguiente:


. = . ( )
.

Pgina 26
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

Dnde:

Hf tub.: prdida de carga o de energa (m)

n: coeficiente de rugosidad

D: dimetro interno de la tubera (m)

Q: caudal (m3/s)

L: longitud de la tubera (m)

Utilizando una sola lnea de Conduccin y empleando las frmulas de Manning se

determin el siguiente cuadro, que muestra la potencia de la bomba requerida

para diferentes dimetros comerciales:


() = .

Donde :
ADT: Altura dinmica total, en m
Q: caudal de diseo, en m3/s

ADT = Desnivel topogrfico (Z) + Prdidas de carga (h)+ presin libre en el

extremo final de la tubera (hl, en este caso consideramos hl =2.00 m)

La energa a requerirse para el sistema de bombeo se determina haciendo uso de

la siguiente frmula:
=

Dnde:

P: potencia de bomba, en KW

T: tiempo de bombeo, en horas

Se considerar el precio de la energa a 0.07 US$ por KW.h.

Pgina 27
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

PARA UNA SOLA LINEA DE CONDUCCIN


Diametro Q rea V hf hl H ADT e POT.B
(m) (m3/s) (m2) (m/2) (m) (m) (m) (m) % (Kw)
0.30 0.737 0.07 10.43 3084.351 154.218 3238.569 3265.569 75 31227.06
0.40 0.737 0.13 5.87 665.641 33.282 698.924 725.924 75 6739.19
0.45 0.737 0.16 4.64 355.302 17.765 373.067 400.067 75 3597.20
0.50 0.737 0.196 3.75 202.633 10.132 212.765 239.765 75 2051.53
0.60 0.737 0.283 2.61 76.679 3.834 80.512 107.512 75 776.32
0.70 0.737 0.385 1.92 33.717 1.686 35.403 62.403 75 341.36
0.80 0.737 0.50 1.47 16.548 0.827 17.376 44.376 75 167.54
0.90 0.737 0.64 1.16 8.833 0.442 9.275 36.275 75 89.43
1.00 0.737 0.79 0.94 5.038 0.252 5.289 32.289 75 51.00
1.10 0.737 0.95 0.78 3.031 0.152 3.183 30.183 75 30.69
1.20 0.737 1.13 0.65 1.906 0.095 2.002 29.002 75 19.30

CUADRO 37. Determinacin de la Potencia de Bomba para cada dimetro asumido

Fuente: Elaboracin Propia

3.4 DETERMINACIN DE COSTOS DE CONSTRUCCIN Y OPERACIN

Previamente se determin el nmero de horas de bombeo para el volumen total al ao:

Q 0.737 m3/seg
Segundos 3600 seg
W 2653.83 m3/hora
N Horas 4347.956 Horas

CUADRO 38. Horas de bombeo a lo largo del ao

Fuente: Elaboracin Propia

Mediante el mtodo grafo-analtico se pudieron determinar los costos de


Construccin utilizando el grfico 8. El costo de operacin representa el costo de energa
producto del bombeo necesario. El cuadro 39. Muestra dichos datos.

Pgina 28
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

RELACION C = f(D) para la tubera de POLIESTER, instalada

4 00 0

3 50 0

3 00 0
Costo del M.L, en US$

2 50 0
y = 1E-07x 3 - 0.0001x 2 + 0.5338x - 52.761
R2 = 0.998
2 00 0

1 50 0

1 00 0

5 00

0
0 1 00 2 00 3 00 4 00 5 00 6 00 7 00 8 00 9 00 1 00 0 1 10 0 1 20 0 1 30 0 1 40 0 1 50 0 1 60 0 1 70 0 1 80 0 1 90 0 2 00 0 2 10 0 2 20 0 2 30 0 2 40 0 2 50 0 2 60 0 2 70 0 2 80 0 2 90 0 3 00 0

Dimetro, en mm

Grfica: N08 Determinacin de los costos de construccin

Fuente: Docente

Diametro Tiempo Energa Co Cc por m Cc Cro Crc


(m) (horas) (Kw*hora) $ $ $ $/m3 $/m3 $/m3
0.45 4347.956 15640472.3 1094833.06 176.3115 1586803.5 0.949 0.138 1.086
0.50 4347.956 8919950.4 624396.53 201.639 1814751.0 0.541 0.157 0.698
0.60 4347.956 3375408.9 236278.63 253.119 2278071.0 0.205 0.197 0.402
0.70 4347.956 1484225.9 103895.81 306.199 2755791.0 0.090 0.239 0.329
0.80 4347.956 728455.3 50991.87 361.479 3253311.0 0.044 0.282 0.326
0.90 4347.956 388830.2 27218.11 419.559 3776031.0 0.024 0.327 0.351
1.00 4347.956 221754.6 15522.82 481.039 4329351.0 0.013 0.375 0.389
1.10 4347.956 133428.8 9340.02 546.519 4918671.0 0.008 0.426 0.434
1.20 4347.956 83914.4 5874.01 616.599 5549391.0 0.005 0.481 0.486

CUADRO 39. Determinacin de Costos de operacin y construccin

Fuente: Elaboracin Propia

Finalmente se determin el dimetro econmico empleado para generar gastos menores

e innecesarios.

Pgina 29
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

1.200
DETERMINACIN DEL DIMETRO ECONMICO
1.000
Costo Reducido Total ($/m3)

0.800

0.600 Cro
Crc

0.400 Cro + Crc

0.200

0.000
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40
Dimetro (m)

Grfica: N09 Costos Reducidos vs Dimetro

Fuente: Elaboracin Propia

Los Resultados fueron los siguientes:

DIMETRO ECON. 80 cms


COSTO RED. TOTAL 0.326 $/m3
COSTO TOTAL 3763229.74 $

CUADRO 39. Dimetro Econmico

Fuente: Elaboracin Propia

Pgina 30
DETERMINACION DEL CAUDAL DE DISEO Y DIAMETRO DE LA LINEA DE CONDUCCION DE AGUA PARA
CAMPO DE RIEGO, SOBRE LA BASE DEL USO CONSUNTIVO DE LOS CULTIVOS

Se midi mediante el punto ms bajo de a curva de Sumatoria de costos reducidos de

operacin y construccin, como resultado se obtuvo un dimetro de 80cm, la cual la

velocidad de caudal est dentro del rango permisible.

Pgina 31