You are on page 1of 2

Page :1/2

UNIT-3 : HEAT BALANCE CALCULATION

Date : 9/8/2008 DOSING AIR :


Section : KILN TEMPERATURE (OC) : 34 HEAT OUTPUT (KCAL/Kg CLINKER) :
Calculations by : PROCESS DEPT VOLUME (NM3/KG) : 0.088
PLANT CAPACITY TPD : 1200
AMB. TEMPERATURE (OC) : 35 PRIMARY AIR : 1. HEAT FOR CLINKERISATION : 409.37
TEMPERATURE (OC) : 33 2. HEAT CARRIED BY PH EXHAUST GAS : 185.03
CLINKER COMPOSITION : VOLUME (NM3/KG) : 0.056 3. HEAT CARRIED BY COOLER EXHAUST GAS : 68.04
% SiO2 : 22.38 4. HEAT CARRIED BY PH EXHAUST GAS DUST : 3.91
% Al2O3 : 5.47 RADIATION LOSSES (kcal/Kg CLINKER): 5. HEAT FOR MOISTURE EVAPORATION : 4.95
% Fe2O3 : 4.20 KILN SHELL: 44 6. HEAT CARRIED BY CLINKER : 35.97
% CaO : 64.89 PREHEATER : 17 7. RADIATION LOSSES : 183.9
% MgO : 1.19 COOLER SIDE : 122.9 8. HEAT CARRIED BY BYPASS GAS : 0.00
HEAT CARRIED BY BYPASS DUST : 0.00
PH EXHAUST GAS : DECARBONISATION LOSS : 0.00
TEMPERATURE (OC) : 353 BYPASS :
VOLUME (NM3/KG) : 1.56 VOLUME AT KILN INLET (NM3/KG) : 0.00
DUST LOAD (gms/NM3) : 50 % BYPASS CONSIDERED : 0 TOTAL HEAT OUTPUT (KCAL/Kg CLINKER) : 891.17
GAS TEMP. AT KILN INLET (OC) : 0
RAW MEAL : DUST LOAD (gms/NM3) : 0
AMOUNT (Kg/Kg of CLINKER) : 1.6 HEAT INPUT (KCAL/Kg CLINKER) :
TEMPERATURE (OC) : 60
MOISTURE (%) : 0.5
SP. HEAT OF AMBIENT AIR (KCAL/NM3) : 0.311 1. HEAT FROM COOLING AIR : 5.20
CLINKER : SP. HEAT OF PH. EXHAUST GAS (KCAL/NM3) : 0.356 2. HEAT FROM DOSING AIR : 0.38
TEMPERATURE (OC) : 204 SP. HEAT OF COOLER EXH. GAS (KCAL/NM3) : 0.320 3. HEAT FROM PRIMARY AIR : 0.23
SP. HEAT OF DOSING AIR (KCAL/NM3) : 0.311 4. HEAT FROM RAW MEAL : 13.71
COOLER EXHAUST GAS : SP. HEAT OF RAW MEAL (KCAL/Kg) : 0.214 5. HEAT FROM FUEL : 871.65
TEMPERATURE (OC) : 239 SP. HEAT OF KILN DUST (KCAL/Kg) : 0.235
VOLUME (NM3/KG) : 0.970 SP. HEAT OF CLINKER (KCAL/Kg) : 0.195
SP. HEAT OF DUST AT KILN INLET (KCAL/Kg) : 0.209 TOTAL HEAT INPUT (KCAL/Kg CLINKER) : 891.17
COOLING AIR : SP. HEAT OF GAS AT KILN INLET(KCAL/NM3) : 0.323
TEMPERATURE (OC) : 29
VOLUME (NM3/KG) : 1.86

Note: Raw Meal to Clinker Factor = 1.60 kg / kg clinker.

Calculation by: B.Ravindran


Page :2/2
UNIT-3 : HEAT BALANCE CALCULATION

PH EXHAUST GAS : RAW MEAL : CLK. TEMPERATURE (OC) : 204 COOLING AIR :
TEMPERATURE (OC) : 353 Kg/Kg of CLINKER : 1.6 COOLER EXHAUST GAS : TEMPERATURE (OC) : 29
VOLUME (NM3/KG) : 1.56 TEMPERATURE (OC) : 60 TEMPERATURE (OC) : 239 VOLUME (NM3/KG) : 1.86
DUST LOAD (gms/NM3) : 50 MOISTURE (%) : 0.5 VOLUME (NM3/KG) : 0.97 DATE: 9/8/2008

HEAT OUTPUT KCAL/ Kg CLINKER HEAT INPUT KCAL/ Kg CLINKER

Clinkerisation
45.94% 409.37 Sensible heat cooling air
5.20 0.58%
PH Exhaust gas
20.76% 185.03
Sensible heat dosing air
Cooler Exhaust gas 0.38 0.04%
7.63% 68.04

PH Exhaust dust PLANT CAPACITY Sensible heat primary air


0.44% 3.91 1200 TPD 0.23 0.03%

Moisture AMB. TEMP.


0.56% 4.95 35 OC Sensible heat raw meal
13.71 1.54%
Exit clinker
4.04% 35.97
FUEL
Radiation losses 871.65 97.81%
20.64% 183.9

By pass losses
0.00% 0.00

891.17 TOTAL HEAT INPUT (KCAL/Kg CLINKER) : 891.17

Calculation by: B.Ravindran

You might also like