You are on page 1of 11

UNIVERSIDAD Fluid Flow Simulation Project

NACIONAL DE TRUJILLO TRUJILLO-


LA LIBERTAD http://www.unitru.edu.pe/ Report

MARTIN AKIRA MZ M LT 18
TAMSHIRO CENAS VILLA DEL
CONTADOR 1051401514

ANLISIS DE FLUJO EN UN DUCTO VENTURI

SOLIDWORKS Flow Simulation


Project Report

November 19, 2017

[Model Picture here]


Fluid Flow Simulation Report

Learn more about SOLIDWORKS Flow Simulation

II
Fluid Flow Simulation Report

Table of Contents
1 General Information .......................................................................................................... 1
1.1 Analysis Environment ................................................................................................. 1
1.2 Model Information ..................................................................................................... 1
1.3 Project Comments:(enunciado del problema) .................................................................... 1
1.4 Size of Computational Domain ...................................................................................... 1
1.5 Simulation Parameters ................................................................................................ 1
1.5.1 Mesh Settings ........................................................................................................ 1
1.5.2 Material Settings .................................................................................................... 2
1.5.3 Initial Conditions .................................................................................................... 2
1.5.4 Boundary Conditions ............................................................................................... 2
1.5.5 Volumetric Heat Sources .......................................................................................... 3
1.5.6 Engineering Goals ................................................................................................... 3
1.6 Analysis Time ........................................................................................................... 3
2 Results ......................................................................................................................... 4
2.1 Analysis Goals ........................................................................................................... 4
2.2 Global Min-Max-Table .................................................................................................. 4
2.3 Results ................................................................................................................... 5
2.4 Conclusion .............................................................................................................. 6
3 Appendix ....................................................................................................................... 8
3.1 Material Data............................................................................................................ 8

III
Fluid Flow Simulation Report

1 General Information
Objectivo de la simulacin: Apreciar mediante grficos y esquemas como es el comportamiento de la velocidad y la
presin de un fluido dentro del volumen de control tomado en el ducto Venturi.

1.1 Analysis Environment


Software Product: Flow Simulation 2016 SP2.0. Build: 3350
CPU Type: Intel(R) Core(TM) i3 CPU 550 @ 3.20GHz
CPU Speed: 3192 (2777) MHz
RAM: 3893 MB / 8388607 MB
Operating System: Windows 7 Service Pack 1 (Build 7601)

1.2 Model Information


Model Name: Pieza1.SLDPRT
Project Name: Ducto

1.3 Project Comments: (enunciado del problema)


Unit System: SI (m-kg-s)
Analysis Type: Internal

1.4 Size of Computational Domain

Size
X min 0.084 m
X max 15.916 m
Y min -4.008 m
Y max 4.008 m
Z min -4.008 m
Z max 4.008 m

1.5 Simulation Parameters


1.5.1 Mesh Settings
1.5.1.1 Basic Mesh

Basic Mesh Dimensions


Number of cells in X 32
Number of cells in Y 16
Number of cells in Z 16

1.5.1.2 Analysis Mesh


Total Cell count: 18466
Fluid Cells: 8510
Solid Cells: 9956
1
Fluid Flow Simulation Report
Partial Cells: 4324
Trimmed Cells: 0

1.5.1.3 Additional Physical Calculation Options


Heat Transfer Analysis: Heat conduction in solids: Off
Flow Type: Laminar and turbulent
Time-Dependent Analysis: Off
Gravity: Off
Radiation:
Humidity: Off
Default Wall Roughness: 0 micrometer

1.5.2 Material Settings

Material Settings
Fluids
Air

1.5.3 Initial Conditions

Initial Conditions
Thermodynamic parameters Static Pressure: 101325.00 Pa
Temperature: 293.20 K
Velocity parameters Velocity vector
Velocity in X direction: 0 m/s
Velocity in Y direction: 0 m/s
Velocity in Z direction: 0 m/s
Turbulence parameters

1.5.4 Boundary Conditions

Boundary Conditions
VELOCIDAD DE ENTRADA
Type Inlet Velocity
Faces Face<1>@LID2
Coordinate system Face Coordinate System
Reference axis X
Flow parameters Flow vectors direction: Normal to face
Velocity normal to face: 10.000 m/s
Fully developed flow: Yes
Thermodynamic parameters Approximate pressure: 101325.00 Pa
Temperature: 293.20 K

PRESION AMBIENTAL
Type Environment Pressure
Faces Face<2>@LID1

2
Fluid Flow Simulation Report
Coordinate system Face Coordinate System
Reference axis X
Thermodynamic parameters Environment pressure: 101325.00 Pa
Temperature: 293.20 K
Turbulence parameters Boundary layer parameters
Boundary layer type: Turbulent

1.5.5 Volumetric Heat Sources

1.5.6 Engineering Goals

1.6 Analysis Time


Calculation Time: 60 s
Number of Iterations: 61
Warnings: A vortex crosses the pressure opening Boundary Condition : PRESION AMBIENTAL ; Inlet
flow/outlet flow=0.174595

3
Fluid Flow Simulation Report

2 Results
2.1 Analysis Goals

Goals
Name Unit Value Progress Criteria Delta Use in
convergence

2.2 Global Min-Max-Table

Min/Max Table
Name Minimum Maximum
Density (Fluid) [kg/m^3] 1.09 1.36
Pressure [Pa] 87651.45 114370.32
Temperature [K] 273.09 293.38
Temperature (Fluid) [K] 273.09 293.38
Velocity [m/s] 0 198.716
Velocity (X) [m/s] -45.850 198.609
Velocity (Y) [m/s] -74.518 74.833
Velocity (Z) [m/s] -73.524 73.825
Mach Number [ ] 0 0.60
Velocity RRF [m/s] 0 198.716
Velocity RRF (X) [m/s] -45.850 198.609
Velocity RRF (Y) [m/s] -74.518 74.833
Velocity RRF (Z) [m/s] -73.524 73.825
Vorticity [1/s] 0.01 1027.30
Relative Pressure [Pa] -13673.55 13045.32
Shear Stress [Pa] 0 243.88
Bottleneck Number [ ] 4.8212509e-014 1.0000000
Heat Transfer Coefficient 0 0
[W/m^2/K]
ShortCut Number [ ] 3.8344735e-014 1.0000000
Surface Heat Flux [W/m^2] 0 0
Surface Heat Flux (Convective) -4.418e+007 1.044e+007
[W/m^2]

4
Fluid Flow Simulation Report
2.3 Results

PRESIN VS. LONGITUD


140000

120000

100000
Pressure [Pa]

80000

60000 Croquis2

40000

20000

0
0 2 4 6 8 10 12 14 16 18

Length [m]

VELOCIDAD VS. LONGITUD


250

200
Velocity [m/s]

150

Croquis2
100

50

0
0 2 4 6 8 10 12 14 16 18

Length [m]

5
Fluid Flow Simulation Report

2.4 Conclusion

Se concluye que en el DUCTO DE VENTURI; en la velocidad los picos ms altos se presentan en el cuello de botella,
meintras que los puntos ms bajos estan en los extremos de los compartimentos y con lo que respecta a la presin los
puntos ms altos se dan el la primera cavidad mientras que en la seguna cavidad estan los valores de presion
intermedios, en el cuello de botella se presentan los valores menores.

6
Fluid Flow Simulation Report

7
Fluid Flow Simulation Report

3 Appendix
2.5 Material Data

Engineering Database
Gases
Air
Path: Gases Pre-Defined
Specific heat ratio (Cp/Cv): 1.399
Molecular mass: 0.0290 kg/mol
Dynamic viscosity
Dynamic viscosity[Pa*s]

Temperature[K]

Specific heat (Cp)


Specific heat (Cp)[J/(kg*K)]

Temperature[K]

Thermal conductivity

You might also like