You are on page 1of 12

15P/30P Series

High Pressure Filters

Global Filtration Technology

93
High Pressure Filters
15P/30P Series

Applications for
15P/30P Series filters
Indicators
Saw mills Both visual auto
reset style and dual
Aircraft ground indicator visual/
support equipment electrical style
available to suit Straight
Asphalt pavers your application. Thread Ports
Hydraulic fan drives New patented SAE straight
design resists false thread for
Power steering circuits signaling due positive
to vibration. sealing
Waste trucks
Cement trucks
Servo control protection
Logging equipment

These application examples have


one thing in common...the need
for clean hydraulic fluid.
Bypass Valve
Modern high pressure hydraulic (not visible)
Bowl Construction May be
systems are demanding. Better Formed of high
controls and long component blocked
grade 6061 for critical
life are expected. To deliver the T6 aluminum applications
high standards of performance, Black anodized,
hydraulic components are built corrosion
with tighter tolerances which resistant finish
increases their sensitivity Knurled for easier
to contamination. gripping when
removing and
Thats where Parker pressure re-assembling
filters come into play. They Hex
filter out ingressed contamination (not visible)
Hex formed
before it jams a valve or scores
at base
a cylinder. They block pump of bowl
generated debris before it gets for easy
to servo or proportional valves. removal
Parker pressure filters are a Bowl
key ingredient in meeting Configurations
todays system demands. Single and double
length bowls avail-
Put your hydraulic systems in the able to cover a wide
range of flows Drain Port
care of Parker Hydraulic Filter
30P available in a (not visible)
Division. We are committed to duplex version.
designing and building the best Clean and
filters available to industry. easy servicing
Lets you drain
bowl before
element
changes

Parker Hannifin Corporation


Hydraulic Filter Division
94 Metamora, OH
High Pressure Filters
15P/30P Series

Quality elements make


the difference
The important item in a filter
assembly is the element. It must
capture and retain contaminants
that can damage system O-Ring Seal
Positive sealing Engineered
components. At the same time it for optimum Element Design
must allow flow to pass as freely as element efficiency The right combination
possible to perform its function. of pleat depth and
number of pleats means
There are many ways to design and lower pressure losses
build an element, and its easy to Wire (longer life)
produce a low cost element. Reinforced Media Dirt holding capacity
However, cost is not the only Prevents pleat is maximized for
bunching less frequent element
selection criteria, especially when change-out
the risk is loss of critical machine Helps prevent
performance. media migration
Maintains media
efficiency
For instance, wire mesh
reinforcement. Not all filter
elements have it. Its used in Parker
elements to keep the pleats from Zinc Dichromate
bunching or collapsing. If pleats End Caps (15P)
bunch, the effective surface area of Excellent corrosion
the element is reduced, excessive protection
pressure drop develops, and the Strong adhesion
filter assembly may go into means no element
separation Elements for
premature bypass mode. Every Application
Standard Microglass III media
There are many other features that for long life and excellent
are included standard with every system protection
quality Parker element. The table
below outlines several.

Feature Advantage Benefit


Wire reinforced Rugged construction, stands The reliable filtration
Microglass III elements up to abuse of cyclic flows provided assures equipment
without performance loss protection, reduces down-
Wire support reduces pleat time, maximizes element life,
bunching, keeps pressure and allows the hydraulic
drops consistent system to operate properly
Multipass tested elements Filter performance backed Filters you select have
(per ANSI/NFPA by recognized and accepted known performance levels
T3.10.8.8 R1-1990) laboratory test standards
Complete element All pertinent information is Provides an easy guide to
performance data disclosure provided in an easy-to- proper filter selection
compare format

Parker Hannifin Corporation


Hydraulic Filter Division
95 Metamora, OH
High Pressure Filters
15P/30P Series

15P-1 Element Performance

Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10,000 100

05Q
10Q
05Q
02Q 6
20Q 80
1,000 99.9
10Q 5

200 99.5 60
4

20Q
100 99.0
3
40
20 95.0
2
02Q
20
1
2 50.0
1 0 0
0 5 10 15 20 25 0 1 2 3 4 5 6
Particle Size (Micrometre) Grams

Multipass tests run @ 10 gpm to 100 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
25 25
150SUS 150SUS
1.5 1.5
20 20

03C
15 1.0 15
02Q 1.0
PSID

PSID
BAR

BAR

05Q 10Q 10C


10 10 g
20Q usin
0.5 Ho 20C 0.5
pty
5 5 Em

0 0.0 0 0.0
0 5 10 15 20 0 5 10 15 20
GPM GPM

Parker Hannifin Corporation


Hydraulic Filter Division
96 Metamora, OH
High Pressure Filters
15P/30P Series

15P-2 Element Performance

Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10,000 100

05Q
02Q
10Q
6
80
1,000 05Q 99.9

20Q

02Q
10Q
20Q 5

200 99.5 60
4
100 99.0
3
40
20 95.0
2

20
1
2 50.0
1 0 0
0 5 10 15 20 25 0 5 10 15 20
Particle Size (Micrometre) Grams

Multipass tests run @ 15 gpm to 100 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 20 40 60 80 0 20 40 60 80
25 25
150SUS 150SUS
1.5 1.5
20 20
03C
g
sin

15 1.0 15 1.0
ou
PSID

PSID
BAR

BAR
yH

02Q
pt

10 10
Em

05Q
10Q 0.5 0.5
20Q 10C 20C
5 5

0 0.0 0 0.0
0 5 10 15 20 25 0 5 10 15 20 25
GPM GPM

Parker Hannifin Corporation


Hydraulic Filter Division
97 Metamora, OH
High Pressure Filters
15P/30P Series

30P-1 Element Performance

Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10,000 100

10Q 6
80
05Q 99.9
1,000

10Q

02Q
02Q 5

200 99.5 60
20Q 4
100 99.0
3
40
20 95.0

05Q
2

20
1
20Q
2 50.0
1 0 0
0 5 10 15 20 25 0 5 10 15 20
Particle Size (Micrometre) Grams

Multipass tests run @ 20 gpm to 100 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 50 100 150 0 50 100 150
25 25
150SUS 150SUS
1.5 1.5
20 20
02Q 03C
10C
15 1.0 15 1.0
PSID

PSID
BAR

BAR
g

05Q
in

10Q
us
Ho

10 10
y
pt

20Q
20Q
Em

0.5 0.5
5 5

0 0.0 0 0.0
0 10 20 30 40 50 0 10 20 30 40 50
GPM GPM

Parker Hannifin Corporation


Hydraulic Filter Division
98 Metamora, OH
High Pressure Filters
15P/30P Series

30P-2 Element Performance

Efficiency Capacity
Beta Rating Efficiency % PSID BAR
10,000 100

05Q
02Q

6
10Q 80
1,000 05Q 99.9
5

02Q
200 99.5 60
20Q
4

10Q
100 99.0
3
40
20 95.0
2

20
1
2 50.0 20Q
1 0 0
0 5 10 15 20 25 0 10 20 30 40
Particle Size (Micrometre) Grams

Multipass tests run @ 30 gpm to 100 psid terminal - 5mg/L BUGL

Flow vs. Pressure Loss


LPM LPM
0 50 100 150 200 0 50 100 150 200
25 25
150SUS 150SUS
1.5 1.5
20 20

03C
15 1.0 15 1.0
g
PSID

02Q
PSID
BAR

BAR
in
us
Ho

10 10
y
pt

05Q 10Q
Em

20Q 0.5 10C 0.5


20C
5 5

0 0.0 0 0.0
0 10 20 30 40 50 60 0 10 20 30 40 50 60
GPM GPM

Parker Hannifin Corporation


Hydraulic Filter Division
99 Metamora, OH
High Pressure Filters
15P/30P Series

Specifications: 15P Element Condition Indicators:


Visual (optional) 360 green/ red
Pressure Ratings: Electrical/ Visual (optional)
Maximum Allowable Operating Pressure 5A @ 240VAC, 3A @ 28VDC
(MAOP): 3000 psi (206.9 bar) Electrical-heavy duty (optional)
Rated Fatigue Pressure: 2000 psi (138 bar) .25A (resistive) MAX 5 watts
Design Safety Factor: 3:1 12 to 28 VDC & 110 to 175 VAC
Operating Temperatures: Color Coding:
Buna: -40F (-40C) to 225F (107C) White (common)
Fluorocarbon: -15F (-26C) to 275F (135C) Black (normally open)
Blue (normally closed)
Element Collapse Rating:
Standard- 350 psid (24.1 bar) Weights (approximate):
H Option- 2000 psid (138 bar) 15P-1 3.5 lb. ( 1.6 kg.)
X Option- 3000 psid (206.9 bar) 15P-2 4.6 lb. ( 2.1 kg.)
Materials:
Bowl: impacted aluminum (anodized 6061-T6)
Head: extruded aluminum (anodized 6061-T6)
Bypass: nylon

Linear Measure: millimeter


inch

Top View
Torque 55-70 Ft Lbs
101.6
4.00 SAE-12 (1-1/16-12 UN-2B)
23.0
.91 Straight Thd Boss Port
Torque 79-90 Ft Lbs
(Ref to SAE J-514)
46.0
1.81

87.0 Visual Indicator Electrical/ Visual Indicator


79.4 Dia. 3.43
31.3 42.4
50.5 Rotates 360
1.67
1.99 Max
79.4.13
3.125.005
21.8 61.0 Max 59.2 Max
.86 6.22 6.8.13 61.0
.25 2.40 2.33
.266.005 2.40

155.3
6.11
25.4 62.5
1.000 2.46 15P-1
Torque 30-35 Ft Lbs Outlet
250.4 173.5.2.3
9.86 6.83.09

15P-2 15P-1
268.7.2.3
10.58.09
15P-2 50.8
2.00 Optional 5/16 SAE-5
Minimum Drain Port
Cartridge Removal Torque 15-20 Ft Lbs Manifold
Clearance 16.3
.64
88.9
3.50
44.4 2 Plcs
1.75
31.7 40.1
Bottom View
1.25 1.58
64.3
2.53 31.7
1.25 344 Thru

23.9 15.8 2 Plcs


.94 Plugs Supplied With
.63 Bypass Only

Inlet Outlet
.69 Dia. .69 Dia.
2-117 O-ring Boss 2-117 O-ring Boss

Dimensional drawings are for reference only.

Parker Hannifin Corporation


Hydraulic Filter Division
100 Metamora, OH
High Pressure Filters
15P/30P Series

Specifications: 30P/30PD Element Condition Indicators:


Visual (optional) 360 green/ red
Pressure Ratings: Electrical/ Visual (optional)
Maximum Allowable Operating Pressure 5A @ 240VAC, 3A @ 28VDC
(MAOP): 3000 psi ( 206.9 bar) Electrical-heavy duty (optional)
Rated Fatigue Pressure: 2000 psi (138 bar) .25A (resistive) MAX 5 watts
Design Safety Factor: 3:1 12 to 28 VDC & 110 to 175 VAC
Operating Temperatures: Color Coding:
Buna: -40F (-40C) to 225F (107C) White (common)
Fluorocarbon: -15F (-26C) to 275F (135C) Black (normally open)
Blue (normally closed)
Element Collapse Rating:
Standard- 350 psid (24.1 bar) Weights (approximate):
H Option- 2000 psid (138 bar) 30P-1 6.4 lb. (2.9 kg.)
X Option- 3000 psid (206.9 bar) 30PD-1 36 lb. (16.3 kg.)
30P-2 8.7 lb. (3.9 kg.)
Materials: 30PD-2 40 lb. (18.1 kg.)
Bowl: impacted aluminum (anodized 6061-T6)
Head: extruded aluminum (anodized 6061-T6)
Bypass: Nylon
Linear Measure: millimeter
inch

Top View
69.9 3 16 UNC 11.2 Deep Min. 4 Total
Optional 34.9 2.750 8 .44
50.8 Torque 30-40 Ft Lbs
Manifold 1.375 2.000
Plate 101.6
4.00 38.9
1.531
44.5 2 Plcs 34.3
1.75 1.350 Torque 55-70 Ft Lbs
114.3 94.0
3.700 90.1 66.7
4.55 Outlet
12.7 3.55 2.63
3.0 Visual Indicators Electrical/ Visual Indicator
50.8 .500
2.000 Inlet .12 42.4
Max - Rotates 360
22.2 Dia Thru 28.6 1.67
40.9
Manifold .875 1.125 Dia
Option 1.610 81.8 1.9-2.0 Deep 2-Total 63.0
Indicator 3.220 .074-.080 2.48 61.2
10.3
Location .406 Dia Thru 2-119 O-Rings 63.0 2.41
20.3 2.48 Max Max
15.7 Dia 10.7Deep
.62 .42 .800
4-Total
Manifold Mount
Side View Options

Str Thd Boss Port


Side View 1" SAE-16 (1-5/16-12 UN-2B) 210.0 229.6
24.4 Torque 120-140 Ft Lbs 8.27 9.04
.96
30P-1 30P-1 Outlet

75.2 Torque 65-70 Ft Lbs


2.96
319.3
12.57
101.6
30 P-2 4.00
Optional Str Thd Drain Port
Minimum
5/16 SAE-5 (11/2-20 UNF-2B)
Cartridge
Torque 15-20 Ft Lbs
Removal
Clearance
338.8
13.34 69.9
104.8 Dia 2.750
30P-2 Bottom View 92.1 Dia
4.13 34.9
3.63
1.375 10.3
Dia Thru 2 Total
.406

52.3
2.06
28.8 Hex
1.12

19.1 31.8
.75 1.25
101.6
4.000 Optional Mounting Bracket (925563)
Port to Port

Dimensional drawings are for reference only.

Parker Hannifin Corporation


Hydraulic Filter Division
101 Metamora, OH
High Pressure Filters
15P/30P Series

30PD Duplex Filter Diverter Valve


Balance Valve
Low torque for
Safety valve
The Parker 30PD duplex pressure easy servicing
equalizes pressure
filter provides uninterrupted Detent for valve between the
handle prevents two bowls
filtration for equipment that accidental switching
cannot be shut down for servicing. Handle indicates
which filter is in use Operating
The 30PD allows you to simply Instructions
switch the diverter valve and Name tag
service the element while the Vent Valves and operating
Allow for convenient instructions riveted
other side is in service. purging of trapped to manifold
air, and pressure
Pressure balancing valves and
check valves are all neatly
assembled in a compact manifold Ports
Vent Drains
head that makes operation safe, SAE straight
1/8-27 NPT drain
smooth and easy. thread ports for
port, both sides
positive sealing
Vent valves are also included to
insure that all air is purged during
service so that maximum system
performance is achieved. 30PD Empty Housing Flow vs Pressure Loss
To obtain total filter assembly pressure loss, add empty housing loss to the
The Parker 30PD makes use of pressure loss of selected element on 30P element performance pages.
industry proven components.
30PD
Elements are multi-pass tested 25
BAR

in accordance with ANSI/NFPA 1.6 Valve Manifold Flow/Pressure Loss


T3.10.8.8 R1 -1990. Bowls and 1.4 20

head are subjected to rigorous


Differential Pressure

1.2
fatigue testing to insure a trouble 1.0 15

free service life. 0.8


10
0.6

0.4
5
PSI

0.2

0
0 10 20 30 40 50
GPM FLOW LPM
0 25 50 75 100 125 150 175

Installation Dimensions
244.3
9.62 72.4 136.7
122.2 2.85
4.81 5.38
MAX.

IN
152.4 FILTER SCEMATIC
OPERATING
6.00 INS NS

IO N
101.6
4.00
R O TAT

30PD-1
208.3 3.0
1" SAE 16 8.20 .12
309.4 (1.312 12 UN 2B)
12.18 STRAIGHT 30PD-2
MAX. THREAD BOSS 317.5 3.0
F BOTH PORTS 12.50 .12
IN ILTE
SE R
RV
IC
E

152.4
6.00
MAX.
275.6 2.75 101.6
10.85 .25 28.4 4.00 MIN.
1.12 HEX ELEMENT
REMOVAL
CLEARANCE

Parker Hannifin Corporation


Hydraulic Filter Division
102 Metamora, OH
High Pressure Filters
15P/30P Series

Parts List Element Servicing


Index Description 15P 30P 15P/30P
1 Head A. Stop the systems power unit.
In-line Porting B. Relieve any pressure in the filter line
Bypass w/top indicator port 931520 933956
No bypass w/top indicator port 931519 933956 and drain filter bowl if drain port
Bypass w/side indicator port 931522 933955 is provided.
No bypass w/side indicator port 931521 933955 C. Loosen and remove bowl.
Manifold Porting D. Remove element from housing.
Bypass w/indcator port 931135 933954
No bypass w/ indicator port 931523 933954 E. Place new, clean element in housing,
2 Bypass Valve Assembly
centering it on the element locator.
50 psid (in-line model only) 928981 925127 F. Inspect the bowl o-ring and replace
No bypass N/A 925209 if necessary.
3 Elements (see chart on model code page) G. Install bowl and tighten to
4 Bowl O-Ring specified torque.
Buna N92138 N92151
Fluorocarbon V92138 V92151 30PD
5 Bowl
Single without drain 926102 926038
A. Arrow on diverter handle points to the
Single with drain 926450 926040 on-duty chamber.
Double without drain 926103 926039 B. Open off-duty vent valve (vent port
Double with drain 926451 926041
should be plumbed back to reservoir).
6 Drain Plug
W/ buna o-ring 920462 920462 C. Open balance valve slowly to admit
W/ fluorocarbon o-ring 922521 922521 fluid into off duty chamber.
7 Nameplate(unstamped) 920928 920928 D. When fluid is discharged from vent
8 Drive Screws 903393 903393 port, close and tighten.
9 Mounting Spacer Tube (not shown) 925650 N/A
E. Pull up on detent pin and rotate
10 Mounting Bracket Kit N/A 925563 diverter approximately 90 until
11 Blank Indicator Kit 925515 925515 detent relocates in seat.
Indicators (viton seals)
F. Close and tighten balance valve.
12 Visual auto reset 933124 933124
H option (1/2 conduit connection) 932905 932905 G. Open new off-duty vent valve to
E2 option (DIN 43650 connection) 929599 929599 relieve pressure.
13 E3 option (3 pin ANSI/B93.55M connection) 932773 932773
H. Follow steps C-G from 15P/30P
Manifold Mounting Kit N/A 925562 instructions above.
Manifold O-Rings (2 required)
Buna N92117 N92119
I. Close and tighten vent valve.
Fluorocarbon V92117 V92119
Note: consult factory for EPR part numbers
Warning: Do not try and rotate handle
until you equalize pressure with the
13 12 balance valve.

11

1
8 3
4

5
7
10 6
8

71
2

6
5

Parker Hannifin Corporation


Hydraulic Filter Division
103 Metamora, OH
High Pressure Filters
15P/30P Series

HOW TO ORDER:
Select the desired symbol (in the correct position) to construct a model code.
Example:

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9

(Assigned
F3 30P 1 10Q M2 50 NN 19 By Parker)

BOX 1: Seals BOX 5: Indicator BOX 7: Ports


Symbol Description Symbol Description Model Symbol Description
None Buna N (nitrile) N No indicator, no 15P MM SAE-12
F3 Fluorocarbon pressure port 15P XX -manifold porting
E8 EPR P Port plugged 30P NN SAE-16
M2 Visual auto reset 30P XX 1-manifold porting
H Electrical indicator, 30PD NN SAE-16
BOX 2: Basic Assembly w/-14 NPT connection Note: Customer supplies subplate adaptor, or
Symbol Description and 12 leads purchases optional Parker subplate.
15P Pressure filter E Electrical/visual w/
NPT conduit connection
30P Pressure filter and wire leads
30PD Duplex style 30P BOX 8: Options
E2 Electrical/visual (DIN
43650 Hirschman style Symbol Description
connection) 1 None
BOX 3: Length
E3 Electrical/visual (ANSI/ 11 No bypass
Symbol Description B93.55M 3-pin 19 SAE-5 drain port on bowl
Brad Harrison style
1 Single connection) 21 No bypass and drain port
2 Double
Note: For side mount indicators, place
a s after indicator symbol. Not BOX 9: Design Number
BOX 4: Element Media available on 30PD model.
Symbol Description Applied to filter assembly by Parker Filter
20C Cellulose BOX 6: Bypass Or Indicator Setting Division. Use the full filter model code,
10C Cellulose Symbol Pressure Setting including the design number when ordering
03C Cellulose replacement parts, elements and cartridges.
20Q Microglass III 50 50 psid
10Q Microglass III Note: If no bypass option (-11) and an
05Q Microglass III indicator is selected, 50 denotes
02Q Microglass III indicator calibration.
Note: For high collapse rated (2000 psid) elements,
add H behind Q. For 3000 psid collapse
rated elements, add X behind Q.

REPLACEMENT ELEMENTS
Filter Model (Flourocarbon seals)
Media 15P-1 15P-2 30P/30PD-1 30P/30PD-2
20C 925576 925596 922625 925834
10C 925385 925394 922624 925835
03C 925578 925598 922923 925836
20Q 930369Q 930370Q 933135Q 933136Q
10Q 932612Q 932618Q 932624Q 932630Q
05Q 932611Q 932617Q 932623Q 932629Q
02Q 932610Q 932616Q 932622Q 932628Q
I0QH 932615Q 932621Q 932627Q 932633Q
05QH 932614Q 932620Q 932626Q 932632Q
02QH 932613Q 932619Q 932625Q 932631Q
I0QX 933577Q 933579Q 933581Q 933583Q
02QX 933576Q 933578Q 933580Q 933582Q

Please note the bolded options reflect


standard options with a reduced
lead-time. Consult factory on all
other lead-time options.

Parker Hannifin Corporation


Hydraulic Filter Division
104 Metamora, OH

You might also like