PART 1 - GENERAL
1.01 DESCRIPTION:
1.03 REFERENCES:
1. D4263: Test Method for Indicating Moisture in Concrete by the Plastic Sheet
Method.
B. Equivalent British/European codes and standards may be used; however, the equivalency
shall be demonstrated and submitted by the Contractor and approved by the CM/CS.
1.04 SUBMITTALS:
a. Product data for interior concrete floor treatment including printed statement of
VOC content.
PART 2 - PRODUCTS
(NTS: Select next paragraph when clear floor treatment is desired and second paragraph
when floor treatment with color is desired.)
(NTS: Paragraph 2.01 is compliant with Green Building Design, if required in project
design.)
2.01 LIQUID HARDENER (LQH):
A. Manufacturers:
(NTS: Paragraph 2.02 does NOT comply with Green Building Design.)
2.02 DUSTPROOF/SEALER (DPS):
A. Manufacturers:
(NTS: Paragraph 2.03 is compliant with Green Building Design, if required in project
design.)
2.03 EPOXY FLOOR COATING (EFC):
A. Manufacturers:
PART 3 - EXECUTION
A. General:
3.02 APPLICATION:
1. Mix and apply two coats, liquid hardener solution in accordance with
recommendations of manufacturer, with particular attention to age and condition of
new concrete, and the number of applications and curing times required for the
particular product used.
(NTS: Edit the following paragraphs for application of colored floor treatments.)
B. [Dustproof/Sealer (DPS) and Epoxy Floor Coating (EFC):]
1. Perform testing for vapor drive on concrete floors in accordance with ASTM
D4263 prior to application. Do not apply [dustproof/sealer] [and epoxy floor
coating] until test results have been approved by Contractor.
3. Give particular attention to priming of concrete substrate and time laps between
coats when more than one conditioning coat is required.
4. Mix colored surface treatment and apply to sound, fully cured, dry and thoroughly
clean concrete slabs in strict accordance with manufacturer's printed instructions.
a. Total dry film thickness for dustproof/sealer: 4 mils [0.1 mm]. (primer and
topcoat).
b. Total dry film thickness for epoxy floor coating: 8-10 mils [0.2-0.25 mm].
(primer and topcoat).
END OF SECTION