DSE4510/20 ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY
AUTO START AND AUTO MAINS FAILURE BS EN 61000-6-2
EMC Generic Immunity Standard for

CONTROL MODULES the Industrial Environment


BS EN 61000-6-4
EMC Generic Emission Standard for
(ALTERNATOR FREQUENCY & CAN SPEED SENSING) the Industrial Environment

FEATURES ELECTRICAL SAFETY


BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment
The DSE4510 Auto Start Control Electronic J1939 (CAN) and non-
Module and the DSE4520 Auto electronic (alternator frequency *AVAILABLE VARIANTS TEMPERATURE
Mains (Utility) Failure Control sensing) engine support for diesel, Auto start with real time clock BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
Module are suitable for a wide gas and petrol engines all in one BS EN 60068-2-2
4510-03 Auto start with real time clock &
variety of single gen-set variant. With a number of flexible heated display Bb/Be Dry Heat +70 oC
applications. inputs, outputs and protections, the 4510-04 VIBRATION
module can be easily adapted to Auto Mains Failure with real time BS EN 60068-2-6
clock Ten sweeps in each of three
Whilst maintaining functions suit a wide range of applications. 4520-03 major axes
included within higher end Auto Mains Failure with real time 5 Hz to 8 Hz at +/-7.5 mm,
controllers, such as generator or Through USB Communication both clock & heated display 8 Hz to 500 Hz at 2 gn
4520-04
load power monitoring, the modules can be easily configured HUMIDITY
DSE45xx range of especially using the DSE Configuration Suite BS EN 60068-2-30
compact controllers provide the PC Software or can be fully Db Damp Heat Cyclic 20/55 oC
at 95% RH 48 Hours
user with the ultimate size to configured through the module's BS EN 60068-2-78
feature ratio. front panel editor. Cab Damp Heat Static 40 oC
at 93% RH 48 Hours

Monitoring engine speed, oil All DSE products are supported by SHOCK
pressure, coolant temperature, the DSE global technical support BS EN 60068-2-27
Three shocks in each of three major axes
frequency, voltage, current, power team which gives our customers 15 gn in 11 mS
and fuel level, the modules will give and end users access to 24 hour
DEGREES OF PROTECTION
comprehensive engine and system help and advice. PROVIDED BY ENCLOSURES
alternator protection. This will be BS EN 60529
IP65 - Front of module when installed into the
indicated on the largest back-lit control panel with the optional sealing gasket.
LCD icon display in its class via an
array of warning, electrical trip and
shutdown alarms.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
PC

4 4 3

USB CONFIGURABLE DC OUTPUT ANALOGUE SENDERS DC POWER


PORT INPUTS (2 for DSE4510) SUPPLY

DEUTZ
DSE4510/20 ISUZU
PERKINS
CATERPILLAR
MTU
7 VOLVO
CUMMINS
OTHER SCANIA

MAINS (UTILITY) DC OUTPUT GENERATOR / DC OUTPUT GENERATOR CHARGE FUEL AND START ELECTRONIC
SENSING 4520 1 OF 4 LOAD CURRENT 4510 1 OF 2 SENSING ALTERNATOR OUTPUTS ENGINE CAN
(DSE4520) 4520 1 OF 4 (Flexible with CAN)

VOLTS VOLTS
D+ +
+ + W/L

1ph 1 1ph 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N

ISSUE 1

DSEGenset

DSE4510/20 SPECIFICATION

DC SUPPLY
AUTO START AND AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
CONTROL MODULES CRANKING DROPOUTS
(ALTERNATOR FREQUENCY & CAN SPEED SENSING) Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
FEATURES without the need for internal batteries.
DSE4520 LEDs and backlight will not be maintained
during cranking.

MAXIMUM OPERATING CURRENT


85 mA at 12 V, 96 mA at 24 V

MAXIMUM STANDBY CURRENT


DSE4510 51 mA at 12 V, 47 mA at 24 V

MAXIMUM SLEEP CURRENT


35 mA at 12 V, 32 mA at 24 V

MAXIMUM DEEP SLEEP CURRENT


<10 uA at 12 V, <10 uA at 24 V

MAINS (UTILITY) DSE4520 ONLY


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

OUTPUTS
OUTPUT A (FUEL)
10 A short term, 5 A continuous,
at supply voltage

OUTPUT B (START)
KEY BENEFITS KEY FEATURES Fuel and start outputs 10 A short term, 5 A continuous,
Ultimate size to feature ratio Alternator frequency & CAN (configurable when using CAN) at supply voltage
Automatically transfers between speed sensing in one variant 4 configurable DC outputs (2 for AUXILIARY OUTPUTS C & D
mains (utility) and generator Largest back-lit icon display in DSE4510) 2 A DC at supply voltage
(DSE4520 only) its class 3 configurable analogue/digital
AUXILIARY OUTPUTS E & F DSE4520
Hours counter provides accurate Heated display option inputs 2 A DC at supply voltage
information for monitoring and Real time clock provides 4 configurable digital inputs
maintenance periods accurate event logging Configurable staged loading GENERATOR
VOLTAGE RANGE
User-friendly set-up and button Fully configurable via the fascia outputs 15 V to 415 V AC (Ph to N)
layout for ease of use or PC using USB 3 engine maintainance alarms 26 V to 719 V AC (Ph to Ph)
Multiple parameters are communication Engine speed protection
FREQUENCY RANGE
monitored simultaneously which Extremely efficient power save Engine hours counter 3.5 Hz to 75 Hz
are clearly displayed on the mode Engine pre-heat
largest back-lit icon display in 3 phase generator sensing Engine run-time scheduler DIMENSIONS
OVERALL
its class 3 phase mains (utility) sensing Engine idle control for starting & 140 mm x 113 mm x 43 mm
The module can be configured (DSE4520 only) stopping 5.5 x 4.4 x 1.7
to suit a wide range of Compatible with 600 V ph to ph Battery voltage monitoring
PANEL CUT-OUT
applications nominal systems Start on low battery voltage 118 mm x 92 mm
Uses DSE Configuration Suite Generator/load power Configurable remote start input 4.6 x 3.6
PC Software for simplified monitoring (kW, kV A, kV Ar, pf) 1 alternative configuration
MAXIMUM PANEL THICKNESS
configuration Accumulated power monitoring Comprehensive warning, 8 mm
Compatible with a wide range (kW h, kVA h, kVAr h) electrical trip or shutdown 0.3
of CAN engines Generator overload protection protection upon fault condition
-40 C to +85 C
STORAGE TEMPERATURE RANGE
Licence-free PC software (kW) LCD alarm indication
IP65 rating (with optional Generator/load current Event log (50) -40 F to +185 F
gasket) offers increased monitoring and protection
-30 C to +70 C
OPERATING TEMPERATURE RANGE
resistance to water ingress
-22 F to +158 F

-40 C to +70 C (for heated display variant)


RELATED MATERIALS
-40 F to +158 F (for heated display variant)
TITLE PART NOS
DSE4510/20 Installation Instructions 053-157
DSE4510/20 Operator Manual 057-171
DSE4510/20 Configuration Suite PC Manual 057-172 OPTIONAL PARTS

PART PART NUMBER


IP65 Gasket 020-282
DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA
Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-132/09/12 (7) US
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457