Disclaimer
1.1 AVEVA does not warrant that the use of the AVEVA software will be uninterrupted, error-free or free from
viruses.

1.2 AVEVA shall not be liable for: loss of profits; loss of business; depletion of goodwill and/or similar losses; loss of
anticipated savings; loss of goods; loss of contract; loss of use; loss or corruption of data or information; any
special, indirect, consequential or pure economic loss, costs, damages, charges or expenses which may be
suffered by the user, including any loss suffered by the user resulting from the inaccuracy or invalidity of any data
created by the AVEVA software, irrespective of whether such losses are suffered directly or indirectly, or arise in
contract, tort (including negligence) or otherwise.

1.3 AVEVA's total liability in contract, tort (including negligence), or otherwise, arising in connection with the
performance of the AVEVA software shall be limited to 100% of the licence fees paid in the year in which the user's
claim is brought.

1.4 Clauses 1.1 to 1.3 shall apply to the fullest extent permissible at law.

1.5 In the event of any conflict between the above clauses and the analogous clauses in the software licence under
which the AVEVA software was purchased, the clauses in the software licence shall take precedence.

Copyright
Copyright and all other intellectual property rights in this manual and the associated software, and every part of it
(including source code, object code, any data contained in it, the manual and any other documentation supplied
with it) belongs to, or is validly licensed by, AVEVA Solutions Limited or its subsidiaries.

All rights are reserved to AVEVA Solutions Limited and its subsidiaries. The information contained in this document
is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or transmitted without
the prior written permission of AVEVA Solutions Limited. Where such permission is granted, it expressly requires
that this copyright notice, and the above disclaimer, is prominently displayed at the beginning of every copy that is
made.

The manual and associated documentation may not be adapted, reproduced, or copied, in any material or
electronic form, without the prior written permission of AVEVA Solutions Limited. The user may not reverse
engineer, decompile, copy, or adapt the software. Neither the whole, nor part of the software described in this
publication may be incorporated into any third-party software, product, machine, or system without the prior written
permission of AVEVA Solutions Limited, save as permitted by law. Any such unauthorised action is strictly
prohibited, and may give rise to civil liabilities and criminal prosecution.

The AVEVA software described in this guide is to be installed and operated strictly in accordance with the terms
and conditions of the respective software licences, and in accordance with the relevant User Documentation.
Unauthorised or unlicensed use of the software is strictly prohibited.

Copyright 1974 to current year. AVEVA Solutions Limited and its subsidiaries. All rights reserved. AVEVA shall not
be liable for any breach or infringement of a third party's intellectual property rights where such breach results from
a user's modification of the AVEVA software or associated documentation.

AVEVA Solutions Limited, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom.

Trademark
AVEVA and Tribon are registered trademarks of AVEVA Solutions Limited or its subsidiaries. Unauthorised use of
the AVEVA or Tribon trademarks is strictly forbidden.

AVEVA product/software names are trademarks or registered trademarks of AVEVA Solutions Limited or its
subsidiaries, registered in the UK, Europe and other countries (worldwide).

The copyright, trademark rights, or other intellectual property rights in any other product or software, its name or
logo belongs to its respective owner.
MDS Automatic Drawing Production User Guide

Revision Sheet

Date Version Comments / Remarks


September 2011 12.1.1 Issued
January 2012 Copyright added to all pages.
MDS Automatic Drawing Production User Guide
MDS ADP User Guide

MDS ADP User Guide

Contents Page

Automatic Drawing Production


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1
Overview of the MDS Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1
Administrators Role . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:1
MDS Catalogues and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1:2

Using Area Based ADP (Draft Users) . . . . . . . . . . . . . . . . . . . . . . . . 2:1


Starting the Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:1
Starting the MDS-ABA Drawing Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:1
Viewing Existing Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:4
Stored LogFiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:5
MDS User View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:6
MDS Over View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2:7

Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:1
MDS Drawing Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:1
MDS Revision Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:3
MDS Scale Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:6
MDS Layer Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:7
MDS Rescale Pipe Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:9
Update DM Plotfile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3:9

Copyright 1974 to current year. i 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide

Copyright 1974 to current year. ii 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Introduction

1 Introduction

Drawings for Multi-Discipline Supports (MDS) are created using the AVEVA Area Based
Automatic Drawing Production (ADP) application (referred to as ABA).
The purpose of this document is to provide the user with guidance on how to produce MDS
drawings from the design model. A pre-requisite to using MDS-ADP is that the Area Based
ADP application has been installed and configured by the administrator.
It is expected that the MDS-ADP user will not need full AVEVA product training in order to be
able to use the application. However, a minimum level of knowledge is required to be able to
enter and exit DRAFT in the required models.
MDS-ADP allows the user to produce drawings by selecting a support or supports and a
template. In an example of a typical MDS-ADP work process, if a user changes the design
model for a maintenance project, the drawings used in that area may be updated. The user
will enter DRAFT, start ADP, select the area and reproduce all the drawings generated for
that area, running the process overnight.
This guide has been structured to take the MDS-ADP user through all the steps needed to
produce new and modified drawings in a logical order. However, the information has been
compiled in a format that should allow a user to reference a particular aspect of MDS-ADP
to gain specific information.

1.1 Overview of the MDS Application


The MDS application allows the user to create standard supports for pipework, cable trays,
(Both piping based cable trays (BRAN) and cable trays (CTRAY) created by the Cabling
System) and HVAC. The application is highly interactive, enabling the user to design
supports with the minimum of effort. It is also highly configurable allowing the administrator
to define project-related defaults to control the design of supports and to determine the
range and types of ancillary support components that can be used on the project.
The standard supports in this application, which are designed using structural sections, are
template-driven. A default set of structural templates based on British Standard Steelwork
Sections is supplied with the application. All of these templates may be configured to suit
the needs of an office or project to adopt a relevant national standard for steelwork sections.

1.2 Administrators Role


The administrator is responsible for initial setup of the MDS defaults in the DATASETS
stored in the PARAGON database, the default files associated with the MDS application
(refer to the Administrator Guide) and setup of the structural steel sizes associated with the
framework templates. The MDS application is supplied with a British Steel set of framework

Copyright 1974 to current year. 1:1 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Introduction

templates, which the administrator must modify to suit the specific requirements of the
project.

1.3 MDS Catalogues and Specifications


The MDS application is supplied with a catalogue and specification. The range of bore and
components in the catalogue are fixed and should be adequate for all projects. The
catalogue supplied and associated /MDS specification must not be modified by the
administrator or any other user.

Copyright 1974 to current year. 1:2 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

2 Using Area Based ADP (Draft Users)

The only functionality a normal DRAFT user has within the Area Based ADP application is
the ability to create drawings using the administrative elements previously defined by a
DRAFT administrator such as Templates and Tasks. If any of the application components
covered in this user guide do not exist, consult your DRAFT ABA administrator.

2.1 Starting the Application


To begin creating one or more ABA drawings, click on Draft on the top menu bar and select
Auto Drawing Production from the drop-down menu (Figure 2:1.: Draft Main Menu).

Figure 2:1. Draft Main Menu

This loads the ADP top menu bar containing the Area Based ADP menu selections.
(Area Based ADP Defaults in the Settings menu and MDS Drawings in the Create
menu).
For information on setting the MDS Area Based ADP defaults, refer to the MDS
Customisation Guide.

2.2 Starting the MDS-ABA Drawing Process


From within the Automatic Drawing Production module, click on the Create top bar menu
and select MDS Drawings from the drop-down menu (Figure 2:2.: ABA Create menu).

Copyright 1974 to current year. 2:1 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

Figure 2:2. ABA Create menu

The Create MDS Drawing form now appears, allowing the user to begin creating drawings
(Figure 2:3.: Create MDS Drawing form).

Copyright 1974 to current year. 2:2 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

Figure 2:3. Create MDS Drawing form

This form allows you to:


Select either of the two options from the Load Supports menu to populate the form lists
with the available MDS supports:
CE & Below selects and populates the form with all supports below the current
element, including the MDS support the current element belongs to.
All in MDB selects and populates the form with all the MDS supports found in the
current MDB.
Select the Drawing Registry to write the drawing to (select an item from the Drawing
Registry window).
Select any elements to include in a drawing from the lists in the Frameworks, Hangers
and Ancillaries windows. Click on the CE button to select the current element. Lists
can be filtered using the Selection Filter gadget.
Select a template from the Template gadget.
Select existing drawings to be updated or regenerated by clicking the Existing
Drawings button (see Viewing Existing Drawings).
Review the run time logfiles by clicking the Stored LogFiles button (see Stored
LogFiles).
Check the Detail Sheets box to produce steelwork shop detail drawings.
Click on the Apply button to finish the process when satisfied with your selections. This will
initiate the individual MDS ABA drawing creation process for all the selected supports in
each of the support type list gadgets.

Copyright 1974 to current year. 2:3 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

Figure 2:4. Typical MDS ABA Drawing

2.2.1 Viewing Existing Drawings


Click the Existing Drawings button on the Create MDS Drawing form above to view
existing drawings (Figure 2:5.: ABA Browse Sheets form). The latest MDS ABA drawing
created will be displayed (Figure 2:4.: Typical MDS ABA Drawing).

Copyright 1974 to current year. 2:4 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

Figure 2:5. ABA Browse Sheets form

Use this form to:


Refresh the list of available drawings (Select File > Reload from the top menu bar).
Display a form to read any stored log file (Select Browse > Stored LogFiles from the
top menu bar).
Modify Template View(s). Right-click an item to display the ABA Template View form
and access the Views available under the Sheet Template from which the picked
drawing was derived.
Modify Template Sheet. Right-click an item to display the ABA Template Sheet form
and access the Sheet Template from which the picked drawing was derived.
Modify Template Drawing. Right-click an item to display the ABA Template Drawing
form and access the Drawing Template from which the picked drawing was derived.
Click on Cancel to return to the Create MDS Drawing form.

Note: The three modify functions are only available to an ABA DRAFT administrator (Area
Based ADP Administrator Guide).

2.2.2 Stored LogFiles


To access logfiles click the Stored LogFiles button on the Create MDS Drawing form
(Figure 2:3.: Create MDS Drawing form). The form shown in Figure 2:6.: Stored LogFiles
form is displayed.

Copyright 1974 to current year. 2:5 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

Figure 2:6. Stored LogFiles form

Use the browser to navigate to the required directory (the default is %PDMSABALOG%),
and then select the required file. You can then:
View the current LogFile.
Edit a LogFile by selecting Edit and clicking on Apply. This brings up a default editor.
Load the contents of a LogFile into the selection fields of the Create MDS Drawing
form. To do this select Load and click on Apply. This allows you to re-create a previous
process run.
Click on the Dismiss button to return to the Create MDS Drawing form. (If the Process
Drawings Control form is displayed, this can be ignored; click Cancel to close the form).

2.2.3 MDS User View


You will need sufficient working knowledge of DRAFT to make use of this facility.
An additional view may be created on an existing MDS ABA drawing, called a 'User View',
which is displayed on the graphical canvas of the main form in the Automatic Drawing
Production application.
A User View is an additional view created by copying an existing view at the users selected
location on the existing drawing. This view will be regenerated each time the MDS ABA
drawing is recreated, and the drawing creation process will generally update any DRAFT
elements, e.g. Dimensions etc., as required. The User View is recognised by the MDS ABA
application by setting the view attribute SpPurpose to USER. A User View may only be
created from a valid MDS ABA view, and not from a User View.

Copyright 1974 to current year. 2:6 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

You can modify the view as required by modifying attributes and creating or deleting view
elements etc. Manipulation and/or positioning of the DRAFT elements in the view may also
be done.
Select Create > MDS User View from the ADP top menu bar. The prompt Identify VIEW to
be copied from or ESCAPE is displayed.
Identify any element in the view to be copied. The 'Point Construction Option Form' will be
displayed, with the option '2D Cursor hit' selected as default.

Figure 2:7. Point Construction Option form

Locate the centre of the User View on the canvas via the 'Cross Hairs' displayed on the
screen. An exact copy of the copied view is created at the selected location. The view can
now be modified as required.

2.2.4 MDS Over View


An Over View is an additional view created by copying an existing view at the exact location
of the existing view on the existing drawing.
This view will NOT be regenerated each time the MDS ABA drawing is recreated. The Over
View is recognised by the MDS ABA application by setting the view attribute SpPurpose to
USER. An Over View may only be created from a valid MDS ABA view, and not from a User
View.
An Over View only copies the MDS support elements, and does NOT copy anything else,
e.g. Dimensions, Pat No. tags etc.
Select Create > MDS Over View from the ADP top menu bar. The prompt Identify VIEW to
be copied from or Escape is displayed.
Identify any element in the view to be copied. The Over View is created by overlaying the
new Over View exactly over the top of the existing view.
The purpose of this type of view is to clarify the design of the MDS support elements, e.g. as
in a Plan View, by drawing the MDS support elements in full if they are obscured and drawn
in 'hidden detail' representation below the main structural supporting steelwork members.
An additional note inside parenthesis will be added to the existing view title, i.e. (Support
shown in full detail for clarity).

Copyright 1974 to current year. 2:7 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Using Area Based ADP (Draft Users)

Copyright 1974 to current year. 2:8 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

3 Utilities

This section describes the use of the last four items accessible from the Utilities drop-down
menu (Figure 3:1.: Utilities menu).

Figure 3:1. Utilities menu

3.1 MDS Drawing Lock


Use this option to lock a drawing, preventing any changes to be made.

Copyright 1974 to current year. 3:1 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

Select the option Utilities > MDS Drawing Lock and the form shown below is displayed.

Select the Lock Drawing option and click on Apply to lock the drawing.
To unlock a drawing, select Unlock Drawing and click Apply.
A locked drawing will NOT be deleted and/or overwritten via the MDS ABA drawing creation
process, even if the MDS support name is selected in the main 'Create MDS Drawing' form.
However the user will have to check the ABA log file, e.g. %PDMSABALOG%/Aba_7-June-
07_10-52-36.log, for the list of MDS support drawings successfully created or aborted. A
typical ABA log file output is shown below.
====================================
ABA Log File - Processing 1 Drawings
====================================

Entry for Drawing /MDS-ABA-3-VIEWS(METRIC)-PS01005-AREA (=23706/


324,=22384/63420)
End of Process List

Processing Drawing (1 of 1)
-------------------------------------------------------------
7 Jun 2007 10:52:37
Cannot delete old drawing /MDS-ABA-3-VIEWS(METRIC)-PS01005-AREA as
it is locked - Drawing aborted

Drawing (1 of 1) Processed
-------------------------------------------------------------

Draft run-time warnings:


64,353) 0 elements with null or illegal IDNM attributes have been
deleted. IDLIST /MDS-ABA-3-VIEWS(METRIC)-PS01005-AREA/S1/V7/IDLIST/
IDLI
64,353) 0 elements with null or illegal DDNM attributes have been
deleted. VIEW /MDS-ABA-3-VIEWS(METRIC)-PS01005-AREA/S1/V7
64,353) 0 elements with null or illegal IDNM attributes have been
deleted. VIEW /MDS-ABA-3-VIEWS(METRIC)-PS01005-AREA/S1/V7
Cannot delete old drawing /MDS-ABA-3-VIEWS(METRIC)-PS01005-AREA as
it is locked - Drawing aborted

Copyright 1974 to current year. 3:2 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

3.2 MDS Revision Control


To use this function:
1. Select MDS Revision Control from the Utilities menu to display the following form:

2. Click on the New Revision button and the form changes as shown below:

Copyright 1974 to current year. 3:3 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

3. Enter the information you want to add to the drawing. An example is shown below:

Copyright 1974 to current year. 3:4 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

4. Click on the Apply button to update the information on the drawing as shown on the
extract below:

Copyright 1974 to current year. 3:5 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

Subsequent updates of drawings retain revision information. Positioning, revision text, and
number of allowable revisions are controlled via the drawing template. See the MDS
Administrator Guide for more information.

3.3 MDS Scale Override


MDS calculates the scale required to fit the whole support within the views. If this scale is
unacceptable, the user may override the scale calculated by MDS and force a scale to be
used.
To do this:
1. Select MDS Scale Override from the Utilities menu to display the following form:

Copyright 1974 to current year. 3:6 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

2. Select the required scale from the Scale drop-down box and click on the OK button. In
the example shown below a scale of 1/10 has been selected.

3.4 MDS Layer Control


The layers created on a MDS drawing can be controlled.
To do this, Select MDS Layer Control from the Utilities menu to display the following form:

The View gadget shows the current editable view. To turn the whole view on or off, use the
toggle in the top right of the form.
The Layer list shows all the current layers in the selected views. Highlighting a layer
displays its members in the lower box. Right-click on the Layer list to show the following
submenu:

Copyright 1974 to current year. 3:7 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

The Layer Members list shows all the members of a particular layer. Click on a member to
toggle between show, and hide. In the example shown below two members have been set
to hidden.

Each menu item works as follows:


Show All shows all members of the selected layer.
Hide All hides all members of the selected layer.
Show/Hide on selection changes the behaviour of the list so that when the user
selects the list all the members will be shown or hidden depending on their current
state.
Hide Layer by Cursor displays the prompt Identify LAYE in the graphical canvas.
Identifying a single element in a current view will hide all elements contained in the
owning LAYE element. The LAYER list shows the layers that are hidden:

Copyright 1974 to current year. 3:8 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

3.5 MDS Rescale Pipe Symbols


This utility is used to rescale pipe symbols to suit the VSCA view scale attribute.
Select Utilities>MDS Rescale Pipe Symbols from the main menu.
The utility will try to navigate to a DRAFT view element, but if it is unable to navigate to a
view you will be prompted to 'Identify view to rescale pipe symbols' in the graphical canvas.
In both cases once the utility has navigated to a view element, the pipe symbols shown in
the view are automatically rescaled to suit the VSCA view scale attribute.

Note: Currently only two types of pipe symbols may be rescaled on MDS drawings. Both
pipe symbols are represented by DRAFT SLAB (Symbol Label) elements with the
TMRF(Template reference) attribute set to either /DRA/MAS/SYMBOLS/GEN/
BREAKS/BB-1 or /MDS/ABA/TAGS/BREAK/PIPE

3.6 Update DM Plotfile


Select Update DM Plotfile from the Utilities menu to update the Deliverable Manager (DM)
plot file with the latest copy in DRAFT. Use this when modifications have been made in
DRAFT. Update DM Plotfile overwrites the file and runs any post-actions required by DM,
for example DM drawing stickers.

Note: This utility requires that the AVEVA Delivery Manager and AVEVA Model Object
Manager software products are installed and working on the current project.

Copyright 1974 to current year. 3:9 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide
Utilities

Copyright 1974 to current year. 3:10 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
MDS ADP User Guide

Index

A S
Area Based ADP Scale Override . . . . . . . . . . . . . . . . . . . . 3:6
using . . . . . . . . . . . . . . . . . . . . . . . . . 2:1 Stored LogFiles . . . . . . . . . . . . . . . . . . . 2:5

D U
DM Plotfile Utilities menu
updating . . . . . . . . . . . . . . . . . . . . . . 3:9 options . . . . . . . . . . . . . . . . . . . . . . . 3:1
Drawing Lock . . . . . . . . . . . . . . . . . . . . . 3:1

E
Existing Drawings
viewing . . . . . . . . . . . . . . . . . . . . . . . 2:4

L
Layer Control . . . . . . . . . . . . . . . . . . . . . 3:7

M
MDS Application
overview . . . . . . . . . . . . . . . . . . . . . . 1:1
MDS Catalogues . . . . . . . . . . . . . . . . . . . 1:2
MDS Over View . . . . . . . . . . . . . . . . . . . 2:7
MDS Specifications . . . . . . . . . . . . . . . . . 1:2
MDS User View . . . . . . . . . . . . . . . . . . . . 2:6
MDS-ABA Drawing Process
starting . . . . . . . . . . . . . . . . . . . . . . . 2:1

R
Rescale Pipe Symbols . . . . . . . . . . . . . . 3:9
Revision Control . . . . . . . . . . . . . . . . . . . 3:3

Copyright 1974 to current year. Index page 1 12 Series


AVEVA Solutions Limited and its subsidiaries.
All rights reserved.