You are on page 1of 3

Design Of Footing F1

Pw bearing capacity Area of P.C Dimention of R.C Dimention of Col Factor


95 18 5.28 1.25 1.5 0.25 0.5 0.25
Input data: Dim of P.C Footing 2.25 2.5
Mw 6.33 Estimating area of P.C 5.63
Fcu 250 6.33 depth of P.C 40 safe
Moment
Fy 3600 6.33 P.C Root 2.29734
B 100 depth of R.c 50
d 43

Output Data:
C1 6.976
J 0.826
As 7.430

Dim of bar 8 10 12 16 18 20 22 25 28 32
Area of bar 0.503 0.785 1.13 2.01 2.55 3.14 3.80 4.91 6.16 8.05
No of bar 14.8 9.46 6.57 3.69 2.92 2.36 1.95 1.51 1.21 0.92

Check punching :

Qp 10.29 < limit 12.900

Check shear :

Qs 14.93 < limit


Design Of Beam / Slab

Input data:
Mw 5
Fcu 350
Fy 3600
B 30
d 75

Output Data: Minimum Steel RFT :


C1 8.87 As1= 6.875 cm2
J 0.826 As2= 4.371805 cm2
As(req) 3.363 cm2 As3= 3.375 cm2
As(min)= 4.371805 cm2 use minimum steel RFT

Dim of bar 8 10 12 16 18 20 22 25 28 32
Area of bar 0.503 0.785 1.13 2.01 2.55 3.14 3.80 4.91 6.16 8.05
No of bar 6.7 4.28 2.97 1.67 1.32 1.07 0.88 0.68 0.55 0.42

Check shear : Results


1 design for shear
Qw 35 2 safe shear
no. of branches = 2.00 branches 3 ok
qc 11.46
qmax 33.6
qs 23.33

Dim of bar 8 10 12
No of bar 25.17 Fy 2400
10.7 Fy 3600 7.46

You might also like