Categories: Metal; Ferrous Metal; Austenitic; Stainless Steel

Material Notes: Sandvik SAF 2205 is a duplex stainless steel (austenitic-ferritic) characterized by:

Very good fatigue resistance


High resistance to stress corrosion cracking in chloride-bearing environments
High resistance to general corrosion, pitting, and crevice corrosion
High resistance to erosion corrosion and corrosion fatigue
Physical properties that offer design advantages

Service temperature: 100 to 300C (150 to 570F)

Information provided by Sandvik

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.

Physical Properties Metric English Comments


Density 7.80 g/cc 0.282 lb/in

Mechanical Properties Metric English Comments


Tensile Strength, Ultimate 800 MPa 116000 psi Annealed
900 - 1800 MPa 131000 - 261000 psi Flat wire
1450 MPa 210000 psi
@Diameter 5.00 - 8.00 mm @Diameter 0.197 - 0.315 in
1550 MPa 225000 psi
@Diameter 3.50 - 5.00 mm @Diameter 0.138 - 0.197 in
1650 MPa 239000 psi
@Diameter 2.00 - 3.50 mm @Diameter 0.0787 - 0.138 in
1800 MPa 261000 psi
@Diameter 1.25 - 2.00 mm @Diameter 0.0492 - 0.0787 in
1900 MPa 276000 psi
@Diameter 0.800 - 1.25 mm @Diameter 0.0315 - 0.0492 in
2000 MPa 290000 psi
@Diameter 0.500 - 0.800 mm @Diameter 0.0197 - 0.0315 in
2100 MPa 305000 psi
@Diameter 0.300 - 0.500 mm @Diameter 0.0118 - 0.0197 in
2200 MPa 319000 psi
@Diameter 0.200 - 0.300 mm @Diameter 0.00787 - 0.0118 in
2250 MPa 326000 psi
@Diameter 0.150 - 0.200 mm @Diameter 0.00591 - 0.00787 in
Tensile Strength, Yield 450 MPa 65300 psi Annealed wire
@Strain 0.200 % @Strain 0.200 %
1235 MPa 179100 psi
@Diameter 5.00 - 8.00 mm, @Diameter 0.197 - 0.315 in,
Strain 0.200 % Strain 0.200 %
1320 MPa 191000 psi
@Diameter 3.50 - 5.00 mm, @Diameter 0.138 - 0.197 in,
Strain 0.200 % Strain 0.200 %
1405 MPa 203800 psi
@Diameter 2.00 - 3.50 mm, @Diameter 0.0787 - 0.138 in,
Strain 0.200 % Strain 0.200 %
1530 MPa 222000 psi
@Diameter 1.25 - 2.00 mm, @Diameter 0.0492 - 0.0787 in,
Strain 0.200 % Strain 0.200 %
1615 MPa 234200 psi
@Diameter 0.800 - 1.25 mm, @Diameter 0.0315 - 0.0492 in,
Strain 0.200 % Strain 0.200 %
1700 MPa 247000 psi
@Diameter 0.500 - 0.800 mm, @Diameter 0.0197 - 0.0315 in,
Strain 0.200 % Strain 0.200 %
1785 MPa 258900 psi
@Diameter 0.300 - 0.500 mm, @Diameter 0.0118 - 0.0197 in,
Strain 0.200 % Strain 0.200 %
1870 MPa 271000 psi
@Diameter 0.200 - 0.300 mm, @Diameter 0.00787 - 0.0118 in,
Strain 0.200 % Strain 0.200 %
1915 MPa 277700 psi
@Diameter 0.150 - 0.200 mm, @Diameter 0.00591 - 0.00787 in,
Strain 0.200 % Strain 0.200 %
Modulus of Elasticity 200 GPa 29000 ksi as delivered
205 GPa 29700 ksi tempered
Shear Modulus 77.0 GPa 11200 ksi as delivered
79.0 GPa 11500 ksi tempered

Electrical Properties Metric English Comments


Electrical Resistivity 0.00000840 ohm-cm 0.00000840 ohm-cm
@Temperature 20.0 - 100 C @Temperature 68.0 - 212 F

Thermal Properties Metric English Comments


CTE, linear 11.5 m/m-C 6.39 in/in-F Cold worked
@Temperature 30.0 - 200 C @Temperature 86.0 - 392 F
11.5 m/m-C 6.39 in/in-F Cold worked
@Temperature 30.0 - 300 C @Temperature 86.0 - 572 F
12.0 m/m-C 6.67 in/in-F Cold worked
@Temperature 30.0 - 400 C @Temperature 86.0 - 752 F
12.5 m/m-C 6.94 in/in-F Cold worked

http://www.matweb.com/search/datasheet_print.aspx?matguid=ff67a3a6b9be4443a22b0a3f1732c2bb 1/2
13/11/2017 Sandvik Bioline SAF 2205 Wire
@Temperature 30.0 - 100 C @Temperature 86.0 - 212 F
13.0 m/m-C 7.22 in/in-F Aged
@Temperature 30.0 - 100 C @Temperature 86.0 - 212 F
13.5 m/m-C 7.50 in/in-F Aged
@Temperature 30.0 - 200 C @Temperature 86.0 - 392 F
13.5 m/m-C 7.50 in/in-F Aged
@Temperature 30.0 - 300 C @Temperature 86.0 - 572 F
14.0 m/m-C 7.78 in/in-F Aged
@Temperature 30.0 - 400 C @Temperature 86.0 - 752 F
Specific Heat Capacity 0.500 J/g-C 0.120 BTU/lb-F
@Temperature 50.0 - 100 C @Temperature 122 - 212 F
Thermal Conductivity 14.0 W/m-K 97.2 BTU-in/hr-ft-F
@Temperature 20.0 C @Temperature 68.0 F
16.0 W/m-K 111 BTU-in/hr-ft-F
@Temperature 100 C @Temperature 212 F
17.0 W/m-K 118 BTU-in/hr-ft-F
@Temperature 200 C @Temperature 392 F
19.0 W/m-K 132 BTU-in/hr-ft-F
@Temperature 300 C @Temperature 572 F
Maximum Service Temperature, Air 300 C 572 F
Minimum Service Temperature, Air -100 C -148 F

Component Elements Properties Metric English Comments


Carbon, C <= 0.0300 % <= 0.0300 %
Chromium, Cr 22.0 % 22.0 %
Manganese, Mn 0.900 % 0.900 %
Molybdenum, Mo 3.20 % 3.20 %
Nickel, Ni 5.00 % 5.00 %
Nitrogen, N 0.180 % 0.180 %
Phosphorous, P <= 0.0300 % <= 0.0300 %
Silicon, Si 0.500 % 0.500 %
Sulfur, S <= 0.0150 % <= 0.0150 %

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering
calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize
rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.